Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 1 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
52
90
120
150
180
TIME
TO 1 ST
STOP
1:36
1:36
1:36
1:36
1:36
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
SURFACE
INTERVAL
*
IN CHAMBER
ON OXYGEN
50 40
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
3
3
3
3
3
NOT TO
EXCEED 5
MINUTES
10
10
10
10
15
23
31
39
NO OF
AIR
BREAKS
1
2
2
2
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
5:36
50:36
63:36
71:36
79:36
REPET
GROUP
K
N
0
Z
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
70 FEET
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 2 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
40
70
85
100
115
130
150
TIME
TO 1 ST
STOP
2:00
2:00
2:00
2:00
2:00
2:00
2:00
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50
10
10
40
14
20
3
3
10
10
26
31
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
3 10 37
3 10 44
NO OF
AIR
BREAKS
1
2
2
2
2
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
6:00
50:00
61:00
67:00
72:00
78:00
90:00
REPET
GROUP
*
M
N
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
80 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 3 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
32
60
70
80
90
100
110
120
130
TIME
TO 1 ST
STOP
2:24
2:24
2:24
2:24
2:24
2:24
2:24
2:24
2:24
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
3
3
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50
10
10
10
10
40
14
20
25
30
3 10 34
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
3
3
3
10
10
10
39
43
48
NO OF
AIR
BREAKS
2
2
2
1
2
2
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
6:24
50:24
61:24
66:24
71:24
75:24
80:24
89:24
94:24
REPET
GROUP
J
M
N
N
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
90 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 4 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
26
50
60
70
80
90
100
110
120
TIME
TO 1 ST
STOP
2:48
2:48
2:48
2:48
2:48
2:48
2:48
2:48
2:24
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
3
3
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50
10
10
10
10
40
14
20
26
32
3 10 38
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
2
3
3
4
10
10
10
44
49
53
NO OF
AIR
BREAKS
2
2
2
1
2
3
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
6:48
50:48
61:48
67:48
73:48
79:48
90:48
95:48
103:24
REPET
GROUP
I
L
N
O
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
100 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 5 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
22
40
50
60
70
80
90
100
110
TIME
TO 1 ST
STOP
3:12
3:12
3:12
3:12
3:12
2:48
2:48
2:48
2:48
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
3
3
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50
10
10
10
10
40
12
19
26
33
2 3 10 40
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
2
2
2
4
5
12
10
10
10
46
51
54
NO OF
AIR
BREAKS
2
2
3
1
1
3
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
7:12
49:12
56:12
68:12
75:12
89:48
96:48
102:48
112:48
REPET
GROUP
H
L
M
N
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
110 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 6 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
18
30
40
50
60
70
80
90
TIME
TO 1 ST
STOP
3:36
3:36
3:36
3:36
3:12
3:12
3:12
3:12
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
SURFACE
INTERVAL
*
IN CHAMBER
ON OXYGEN
50 40
2
2
2
3
3
4
5
NOT TO
EXCEED 5
MINUTES
10
10
10
10
10
10
9
16
24
32
39
46
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
4 8 10 51
NO OF
AIR
BREAKS
2
2
2
3
1
1
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
7:36
46:36
53:36
66:36
77:12
85:12
98:12
108:12
REPET
GROUP
H
J
L
N
O
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
120 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 7 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
15
30
40
50
60
70
80
90
TIME
TO 1 ST
STOP
4:00
4:00
4:00
3:36
3:36
3:36
3:36
3:36
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50
10
10
40
12
21
2
2
3
5
10
10
29
37
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
2 7 10 45
6
10
10
14
10
10
51
56
NO OF
AIR
BREAKS
1
2
2
2
3
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
8:00
50:00
64:00
74:36
84:36
99:36
112:36
125:36
REPET
GROUP
F
M
N
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
130 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 8 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
13
25
30
35
40
45
50
55
60
65
70
TIME
TO 1 ST
STOP
4:24
4:24
4:24
4:24
4:00
4:00
4:00
4:00
4:00
4:00
3:36
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40 30
3
3
3
SURFACE
INTERVAL
*
IN CHAMBER
ON OXYGEN
50 40
2
2
2
3
3
4
6
NOT TO
EXCEED 5
MINUTES
10
10
10
10
10
10
2
2
7
9
10
10
38
43
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
2
4
7
11
13
10
10
48
51
11
15
20
24
29
33
NO OF
AIR
BREAKS
2
2
2
2
1
1
2
3
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
8:24
49:24
53:24
63:24
70:00
76:00
82:00
88:00
100:00
109:00
119:36
REPET
GROUP
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
140 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
G
J
K
N
N
O
O
Z
Z
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 9 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
11
25
30
35
40
45
50
55
TIME
TO 1 ST
STOP
4:48
4:48
4:48
4:24
4:24
4:24
4:00
3:36
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
2
2
5
2
5
6
7
9
4
7
9
11
14
30
3
3
3
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10
10
10
10
10
10
10
13
18
23
27
33
38
44
NO OF
AIR
BREAKS
2
2
2
2
1
1
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
8:48
51:48
56:48
70:24
80:24
89:24
100:00
121:36
REPET
GROUP
G
K
L
N
N
O
O
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
150 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 10 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
9
20
25
30
35
40
45
TIME
TO 1 ST
STOP
5:12
5:12
5:12
4:48
4:48
4:24
4:00
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
3
3
4
2
4
6
8
30
3
3
3
4
7
9
12
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10
10
10
10
10
10
11
16
21
26
32
38
NO OF
AIR
BREAKS
2
2
2
2
1
1
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
9:12
50:12
55:12
68:48
78:48
92:24
108:00
REPET
GROUP
F
J
K
M
N
N
Z
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
* Surface Interval
160 FEET
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 11 of 16
Table 1-26 SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
7
20
25
30
35
40
TIME
TO 1 ST
STOP
5:36
5:36
5:36
5:12
4:48
4:24
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
4
4
4
5
6
8
30
3
3
3
7
9
13
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10
10
10
10
10
13
19
23
29
36
NO OF
AIR
BREAKS
2
2
2
1
1
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
9:36
52:36
58:36
77:12
90:48
108:24
REPET
GROUP
F
J
L
M
O
O
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
170 FEET
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 12 of 16
Table 1-26x SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
15
TIME
TO 1 ST
STOP
5:36
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
4
30
6
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10 20
30 4:48 2 3 5 10 10 40
45 4:00 2 4
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
6 12 18 10 50
NOTE: NO REPETITIVE DIVES ALLOWED ON THESE TABLES
NO OF
AIR
BREAKS
1
2
2
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
59:36
88:48
120:00
REPET
GROUP
NO
REPET
DIVES
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
180 FEET
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 13 of 16
Table 1-26x SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
15
TIME
TO 1 ST
STOP
5:36
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
2 4
30
6
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10 20
30 5:12 3 5 8 12 10 50
45 4:24 2 5
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
10 18 26 10 50
NOTE: NO REPETITIVE DIVES ALLOWED ON THESE TABLES
NO OF
AIR
BREAKS
1
2
2
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
61:36
103:12
145:24
REPET
GROUP
NO
REPET
DIVES
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
190 FEET
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 14 of 16
Table 1-26x SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
15
TIME
TO 1 ST
STOP
6:00
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
2 5
30
7
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10 20
30 4:48 2 4 6 10 16 10 50
45 4:45 2 5
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
12 20 30 10 70
NOTE: NO REPETITIVE DIVES ALLOWED ON THESE TABLES
NO OF
AIR
BREAKS
1
2
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
64:00
112:48
167:48
REPET
GROUP
NO
REPET
DIVES
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
200 feet
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 15 of 16
Table 1-26x SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
15
TIME
TO 1 ST
STOP
6:24
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
3 4
30
8
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10 20
30 5:12 2 4 7 12 18 10 60
45 5:12 2 6
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
14 24 36 10 70
NOTE: NO REPETITIVE DIVES ALLOWED ON THESE TABLES
NO OF
AIR
BREAKS
1
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
65:24
132:12
181:12
REPET
GROUP
NO
REPET
DIVES
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
210 FEET
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.
Document Title
Document No.
Revision Date
Table 1-26 and 1-26x Surface Decompression Using Oxygen
SDC-HSE-JWL-T126126xSDUO-0010-001
March 16, 2004 Revision No. 1 Page 16 of 16
Table 1-26x SURFACE DECOMPRESSION USING OXYGEN WITH NITROX OR AIR IN WATER STOPS
BOTTOM
TIME
(MINS)
15
TIME
TO 1 ST
STOP
6:24
80
IN WATER Stops (mins) at Depths (feet)
Breathing Nitrox or Air
70 60 50 40
2 4 5
30
10
SURFACE
INTERVAL
*
NOT TO
EXCEED 5
MINUTES
IN CHAMBER
ON OXYGEN
50 40
10 20
30 5:36 2 5 9 14 20 10 60
45 5:36 2 6
SUPERIOR DIVING OPERATIONAL DEPTH/TIME LIMIT
16 30 42 10 70
NOTE: NO REPETITIVE DIVES ALLOWED ON THESE TABLES
NO OF
AIR
BREAKS
1
3
3
ASCENT DECOMP
TIME
(MINS)
10
MINUTES
O2
**
91:24
139:24
195:36
REPET
GROUP
NO
REPET
DIVES
DIVE PROCEDURES – TABLE 1-26 Surface Decompression Using Oxygen with Nitrox or Air in Water Stops
IN WATER PHASE
* Ascent procedures
25 feet per minute to the first stop
Ascent time between stops & from 30 feet to surface is ONE MINUTE
Decompression time as specified begins on arrival at the stop depth
Do not include ascent time as part of stop times
Delays at earlier stops are not to be compensated for at later stops
CHAMBER PHASE
Diver is recompressed to 50 feet in 30 seconds and is to be breathing oxygen within 3 minutes of arriving at 50 feet
Remain at 50 feet for 10 minutes then ascend to 40 feet in 1 minute
On arrival at 40 feet the first air break is given prior to starting Oxygen time at this depth
Breath Oxygen for the time listed broken into cycles of 20 minutes interspersed with 5 minute air breaks
*50/50 Nitrox Switch
Switch to 50/50 Nitrox at 100 feet during ascent
Nitrox decompression mix is not to be connected to the manifold until the diver passes 100 feet
On surface divers umbilical is to be flushed thoroughly with air prior to starting next dive
Umbilical flush is to be formally logged
ASCENT FROM 40 FEET
** On completion of total Oxygen time at 40 feet surface the diver at the rate 4 feet per minute (10 minutes)
Diver to breath Oxygen during the entire ascent.
LOSS OF NITROX
If there is a loss of Nitrox, switch diver to Air and decompress according to table * REPETITIVE DIVES – Are only permitted after a minimum surface interval of 6 hours
Previous bottom time must have been such that divers repet group was no greater than ‘O’
Refer to table 1-10 for Repetitive Group Designator (RGD) not to exceed ‘O’
Refer to Table 1-12 for new RGD at the end of the surface interval
Using new RGD refer to Table 1-13 for Residual Nitrogen Time (RNT)
220 Feet
* Surface Interval
Upon surfacing the diver has 3 and a half minutes maximum to start recompression in the chamber
NOTE: On any occasion that the Depth or Bottom Time falls within 2 feet or 2 minutes of a Depth or Time increment of a schedule use the next Deeper and/or next longer schedule.