uantum Quantum Technology Corp. QUANTUMCOOLER SERIES 4000 The Series 4000 QUANTUMCOOLER systems are fully automatic for unattended 24 hour per day operation. They may be configured for use either as a reliquefier, condensing cold helium gas into liquid or as a liquefier, cooling room temperature helium gas to 4.2 K then condensing it. As a reliquefier, no helium leaves the target dewar and hence no helium gas recovery system is required. This provides closed-cycle cooling for systems which require a liquid helium bath, such as MRI units. The liquefier system allows recondensing of the cold boiloff gas while also permitting the liquefaction of additional helium from a room temperature gas source. Each liquefier system incorporates an automatic internal helium gas purifier. Reliquefier systems are equipped with a flexible, non-magnetic "QUANTUM INTERCONNECT" line, which terminates with a small cold finger residing in the target dewar. Liquefier systems may, if desired, have an internal liquid helium reservoir instead. Model Number Function Capacity Input power (L/day) (kW) 4100 Reliquefier 40 8 4200 Reliquefier 55 12 4110 Liquefier 8 8 4210 Liquefier 16 12 4310 Liquefier 24 16 4310-D-PC Liquefier 37 18 Capacities are nominal, measured at 60 Hz operation with pure inlet helium gas. Reliquefaction rates are maximum based on recondensing 4.2 K gas. Actual rates may vary. Specifications are subject to change without notice. Please enquire about custom systems. OPTIONS: - LV Low voltage version 208-230 V 3ph 60 Hz or 180-200 V 3ph 50 Hz water cooled. - HV High voltage version 440-460 V 3ph 60 Hz or 380-415 V 3ph 50 Hz water cooled. - AIR cooling of compressors in place of water cooling (at an additional cost). - QUANTUM INTERCONNECT available in custom lengths and diameters. - INTERNAL RESERVOIR, up to 60 L, available on liquefier systems. ACCESSORIES: Helium gas recovery system, low pressure version or high pressure version External helium gas purifier for severely contaminated gas. (This is required to maintain full liquefier throughput when the helium gas is impure). Liquid helium dewar. Liquid helium level gauge. Helium gas purity meter. Quantum Technology Corp. BC Research & Innovation Complex, 3650 Wesbrook Mall, Vancouver, BC, V6S 2L2 CANADA Tel: +1-604-222-5539 Fax: +1-604-677-5826 quantum@quantum-technology.com www.quantum-technology.com GERMANY: c/o Ing. Arnold Tel: +49-(0)6343-939690 Fax: +49-(0)6343-8879 KOREA: c/o Seongwoo Instruments Inc. Tel: +82-31-471-5800 Fax: +82-31-471-5115 swi@seongwooinst.com SWITZERLAND: c/o Meili-Kryotech Tel: +41-(0)81-661-7161 Fax: +41-(0)81-661-1724 USA: Blaine, WA Tel: 1-888-271-9466 Fax: 1-888-711-5222 (Toll-free from USA) file: D:\106748398.doc rev. 2000-6-14