E-light+RF+LASER multifunctional beauty machine User’s Manual Page 1 Page 2 Contents Chapter 1 Product structure ...................................................................................................... 3 Chapter 2 Accessories list ......................................................................................................... 4 Chapter 3 Product informaion ...................................................... Error! Bookmark not defined. Chapter 4 Installation.................................................................................................................. 5 Chapter 5 Operation.................................................................................................................... 7 Chapter 6 Treatment ................................................................................................................. 12 6.1 Principle ............................................................................................................................. 12 6.2 Hand-piece and Application .............................................................................................. 13 6.3 Attentions before the treatment ......................................................................................... 14 6.4 Hair removal .................................................................................................................... 14 6.5 Skin rejuvenation ............................................................................................................... 15 6.6 Pigmentation Therapy ....................................................................................................... 16 6.7 Vascular Therapy............................................................................................................... 17 6.8 Acne Therapy .................................................................................................................... 17 6.9 Wrinkle removal ................................................................................................................. 18 6.10 After Treatment Care ..................................................................................................... 18 Chapter 7 Service manual ........................................................................................................ 19 Chapter 8 Maintenance ............................................................................................................. 20 Page 3 CAUTION 1. When you received the new machine, please open it work one minute (enjoin from the machine working). 2. shut down the machine. 3. Affusion water again 4. Anew Open the machine 5. When the water stream very well, then you can let the machine working. Chapter 1 Product structure 10.4" TFT color touch screen Hand-piece Key switch Emergency stop button CPC connector Page 4 Overflow hole Infusion hole circuit breaker Power plug Remote control Drain hole Chapter 2 Accessories list hand-piece and 5 filters Funnel Protect glass Goggle Key switch laser handle RF handle Power cord RF tips laser tips Chapter 3 Product informaion 3.1 Application E light application: 1. Therapy acne 2. Reduction of vascular lesions 3. Reduction of pigmented lesions Page 5 4. Skin rejuvenation 5. Permanent hair removal 6. Wrinkle removal RF application: 1. Skin lifting, tightening, and whitening 2. New collagen stimulation and production 3. Removes fine lines and wrinkles 4. Facial remodeling and body contouring 5. Visibly minimize pores 6. Circumference and cellulite reduction 7. Body Shaping areas: abdomen, buttocks, thighs, neck, upper arms. Laser application: 1. 1064nm Wavelength: Remove black and dark blue tattoo pigments, such as tattoos, eyebrows, dark color around the eyes, freckle, age spot etc. 2. 532nm Wavelength: Remove red and brown tattoos and red mark. 3.2 Specification: Wavelength 430/530/560/580/640-1200(nm) E light Handpiece 1 piece with 5 filters RF handle 1 piece with 3 tips Laser handle 1 piece with 2 tips(1064 and 532) Cooling system semiconductor+air+water+cooling gel IPL light energy 1-50(J/cm²) Pulse Duration 1-10ms Pulse NO. 1--6 Skin cooling -4°c-10°c Display 10.4"color touch screen Output power 2000W RF frequency 10MHZ Laser energy 1-1500MJ Laser frequency 1-6HZ Voltage 110V,50HZ or 220V,60HZ Weight 72kg Package size 63cm*60cm*111cm Page 6 Chapter 4 Installation 4.1 The process of installation includes: 1. 2. 3. 4. 5. 6. Unpacking the device. Staying the device for one day, in order to avoid destruction by high humidity during long distant transportation. Assembly of its components and ensure that all connections are firmly in place. Fill the water tank with distilled water only. Connect the power supply. Switch on the device and test all functions / parameters of the system. 4.2 Installation 1) Installation treatment handpiece, please follow the figure,Plug the handpiece connector firmly and properly to avoid the water circulation problem. Figure 4.1 2) Unscrew the Infusion hole cap and the overflow hole cap. (According to the following figure) Page 7 Figure 4.2 3) Infuse distilled water until the water overflow the overflow hole. Overflow hole Figure 4.3 4) 5) 6) Ensure that the key is in the off position and that the emergency cut off button is not engaged. If it is engaged, release it by rotating the button towards the direction of the arrow indicator. Attach the power cord . Switch the circuit breaker to the “On” position. Figure 4.4 7) Switch the unit on by inserting the key and turning it in a clockwise direction. At this time water circulation and the cooling system starts automatically. 8) Observe whether water circulation runs well or not. After cooling system runs for at least 1 minute, the water slide into the cooling system and then turn off the power. 9) Then switch on the system. It means you can fully assemble system with handpiece, screw on the infusion cap. 10) According to the following figure changeable of the various wavelength by 430,530,560, 580,640~1200nm filter for spot size: 12*30mm. Page 8 slot Figure 4.5 11) When replace water 1. Drain the remaining water which contains in the handle. Pay particular attention as not to spill any water on the electronic terminals. Wipe off any spilled water with a soft absorbent cloth. 2. Replace water every 2-3 months. CAUTION 6. 7. 8. 9. Only distilled water is to be used in the cooling system. When using the system for the first time, rinse the cooling system with distilled water. Ensure that the water level is adequate before treatment to prevent over heating. Distilled water is added periodically specially when working in warmer climates and when the treatment handpiece are changed often. 10. Make sure that the treatment head is firmly secured . Chapter 5 Operation WARNING Page 9 1. WARNING: HIGH VOLTAGE: please ensure that all panels are secured prior to operation. 2. Place the treatment head on its support when on standby / simmer mode. 3. All personnel in the treatment room must wear the protective filtered glasses supplied. 4. Make sure the patient is wearing the opaque protective goggles prior to treatment 5. Avoid looking directly into the intense light during the treatment even if you are wearing the protection glasses. 6. Do not point the treatment head outside the treatment field 1.Select Therapy Program Turn on the key switch of the machine,enter “Select Therapy Programs” interface (as Fig.1). Select the treatment model to enter the interface of relevant treatment. (Fig.1) 2.Treatment Interface (E-light) Page 10 (Fig.2) Page 11 After entering the interface of “Treatment interface” (as shown in Fig.2), press “Ready” to trigger the handpiece. Capacitors will be charged automatically. Treatment can begin after charging accomplished. Press “Standby” to turn off the handpiece. Treatment mode:To indicate the current treatment mode. Treatment parameter:treatment parameters recorded in treatment mode. State indication:To indicate the current state and the flash numbers of the handpiece. Treatment record:To indicate the current treatment record, different treatment records can be recorded to facilitate different patients. Treatment records can be altered, three choices available. Cooling adjusting: To adjust the cooling temperature of the handpiece, five levels available. The more blue snowflakes are, the cooler it will get. When the blue snowflakes disappear, cooling stops. Return button: To return to the menu of Select Therapy Program,not available when it is gray (during treatment). IPL energy: To adjust the output energy of the handpiece. Energy value will be displayed on the screen while adjusting, adjustable range: 1~50J/cm2. This setting can be done directly during treatment with “△” or “▽”. “△” to increase, “▽” to decrease,press and hold “△” or “▽” to rapidly adjust the output energy. RF energy: To adjust the RF output energy, Energy value will be displayed on the screen while adjusting, adjustable range: 1~20. This setting can be done directly during treatment with “△” or “▽”. “△” to increase, “▽” to decrease,press “△” or “▽” to rapidly adjust the output energy. The functions of IPL and RF can be turned on or off separately, but make sure that at least one of them is turned on. Pressing “Ready” cannot light the lamp when IPL function is off work. Status Prompted Window Page 12 treatment parameter Adjust treatment parameter ,we can change the output energy of the treatment head, pulse duration, pulse number,thus can get different treatment effect. There are 8 items adjustable. :RadioFrequency(50~2500ms),Unit:50ms,The greater the data, the longer the time of RF. 600ms is recommended Pulse number(1-6), 3 is recommend :Pulse charge interval time(1-4s), 2S is recommended ☻Press '▽' or '△' to increase or decrease parameters First pulse duration:To adjust width of first pulse.The range is 1-10ms. 0.1ms as every unit. First pulse delay:To adjust delay between first pulse and next pulse.The range is 1-100ms,each unit is 1ms. Second pulse duration:To adjust width of first pulse.The range is 1-10ms. 0.1ms as every unit. Second pulse delay:To adjust delay between second pulse and next pulse.The range is 1-100ms,each unit is 1ms. Repeat pulse duration:To adjust duration of third pulse and repeat pulse.The range is 1-10ms,every unit is 0.1ms. Pulse output First Second First Delay Repeat First Second RF delay Page 13 Discharge interval Treatment: Pressing "Ready" button (green) to start treatment head and charge capacitors automatically, Start the treatment after the capacitors finish charging. Press "Standby" button (red) to light up the treatment head, system goes into standby mode. After finishing charging, please wait 10 seconds to start treatment after cooling the treatment head. After pressing "ready" button, any buttons on the screen no response.After releasing the "ready" button,other button can be adjusted At the end of treatment, pressing"standby" button exit the treatment program and close the treatment head. Doing the treatment with RF should make the skin good contact with electrode and daubs cold gel. The energy should adjust from low to high and the time can not keep too long when the skin contacts with electrode to avoid scalding. The feeling of RF treatment is hot inner of the skin. If the tingle is strong, the reason could be that the cold gel is not enough and the skin is not good contacting with electrode. The way to solve the problem is to daubs cold gel again or adjust electrode. RF treatment RF Pulse Cooling RF energy: 1-25 adjustable, usually use 5, you also can increase or decrease according to customer’s feeling. Continuous: RF all the time, so customer’s feeling is hot,and hot. Pulse: RF work, stop, work, stop, so customer’s feeling is hot, cold, hot, cold, more Page 14 comfortable. LASER treatment frequency energy Frequency: 1-6HZ adjustable, usually use 3HZ. YAG: energy, 1-1500mj, usually adjust from 600mj, you can increase according to customer’s feeling and the result. Chapter 6 Treatment 6.1 Principle Elight: E Light(IPL and RF)combines three advanced technologies: Bipolar Radio Frequency + IPL +Skin Contact Cooling.When the three are united in one treatment, wonderful treatment experience and result can beexpected. The energy of Radio Frequency can reach the middle and deep layer of the skin and heat up tissue, thus, lower energy is applied during the IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and better result can be expected. In addition, cooling system involved in E-light can also ease the uncomfortable feeling.The absorbing of the energy of radio frequency is not concerned Page 15 with melanin. So, the E-Lighttreatment can get good result on the soft or thin hair so as to decrease the risk caused by traditional IPL treatment. RF: Using the exclusive radio frequency(RF hereinafter) technology and contact cooling system, RF can improve your appearance obviously. 1. RF produces heat when the tissue's electrical resistance converts the electric current to thermal energy deeper within the dermis. 2. High frequency wave permeates epidermis and take effect on the collagen-rich derma tissue directly which makes the inside water molecules under the take skin more quickly. This move produces controllable heat and results in contraction of collagen and generation of the new collagen and dermal remodeling. 3. The heat will accelerate the blood circle as well. As a result, the skin looks tighter, wrinkles reduce, cellulite and fat reduction gradually. Laser: Laser emitted by the system has a strong penetration ability which allows it to reach the deep layer of dermis. The pigment particles absorb the light energy and explode sharply, burst into the tiny pieces, thus diminish the color density and get rid of it. So the appliance can effectively do away with mutant pigmentations and vascular tissue based on undamaged ambient tissue. This is called ‘Selective heat absorption’ principle in medical field. 6.2 Elight Hand-piece and Application Wavelength Treatment 430-1200nm Acne removal 530-1200nm Freckles removal, Skin rejuvenation 560-1200nm Whitening skin, Skin rejuvenation 590-1200nm Vascular removal, fade melasma, skin rejuvenation 640-1200nm Thick Hair removal Page 16 The darker the skin 1. Decrease the fluence 2. Increase the pulse delay (allow more cooling) The lighter the skin 1. Increase the fluence 2. Decrease the pulse delay The darker the hair / pigmented lesion 1. Decrease the fluence 2. Increase the pulse delay (allow more cooling) The lighter the hair / pigmented lesion 1. Increase the fluence 2. Decrease the pulse delay Fine blood vessels 1. higher fluence 2. Decrease the pulse delay 3. Decrease the pulse width Thicker blood vessels 1. Increase pulse delay (allow more cooling) 2. Increase the pulse width The smaller the target size / lesion 1. Decrease pulse delay The larger the target size / lesion 1. Increase pulse delay (allow more cooling) Bony prominences (forehead, malar area, shins) 1. Decrease the fluence by 10-20% 6.3 Attentions before the treatment 1. Consultation patients who have the following conditions but not limited should not take the treatment : A. Pregnant lady; B. Hypersusceptible to light or recently take medicines, such as acheomycin; C. Skin easy to scar; D. Diabetes (blisters maybe appear and not easy to heal up); E. Insolation in sunlight in recent 2 weeks; F. Heart disease; G. Epilepsy, and contagious skin disease, such as herpes; H. Skin cancer. 2. Preparation When begin the treatment, take off the accessories such as watch, rings, bracelets or other metallic things which might be reflect light and cause danger during the treatment. Wipe off the cosmetic and clean the skin. Ware the goggles to protect the eyes of the patients and the beautician. 3. Sanitize the treatment head with alcoholized cotton balls. 4. Clean the filters with alcoholized cotton balls. 6.4 Hair removal 1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment. 2. Clear treatment area. Page 17 3. Turn on machine ,put the 640nm or 690nm filter into the slot, select "hair removal",adjust the parameter, set it to ‘ready’ . 4. Put cooling gel on treatment area about 2mm. 5. Wear protect goggles for patient and operator. 6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have 1/3 overlapping on treatment area. 7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area until heat disappear. 8. Treatment Parameter: Lady: Skin Type Pulses number First pulse First delay Second pulse Second delay Fluency (640nm filter) Fluency (690nm filter) One 3 6.0 21 6.5 22 33 34 Two 3 6.0 21 6.5 22 31 32 Three 4 5.0 22 5.5 23 29 30 Four 4 4.5 23 5.0 24 27 28 Five 5 4.5 24 5.0 24 26 27 Pulses number First pulse First delay Second pulse Second delay Fluency (640nm filter) Fluency (690nm filter) One 3 5.5 20 6.0 21 32 33 Two 3 5.5 20 6.0 21 30 31 Three 4 5.0 21 5.5 22 28 29 Four 4 4.5 22 5.0 23 26 27 Five 5 4.5 23 5.0 24 25 26 Man: Skin Type ** If application for removal of facial and upper lip area, the fluency should be reduced by 2 to 3 Joules ** If application for fine and thin hair, the fluency can be increased by 1 to 2 Joules,D1 reduce by 1 to 2. ** If application for coarse and thick hair, the fluency can be reduced by 2 to 3 Joules ,D1 increase by 1 to 2. ** If using spot size 15x50mm,the fluency should be increased by 2 to 3 Joules. Page 18 6.5 Skin rejuvenation 1. Clear treatment area. 2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the parameter, set it to ‘ready’ . 3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4℃. 4. Wear goggles for patient and operator 5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have 1/3 overlapping on treatment area. 6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling disappears. 7.Treatment parameter: Skin Type Pulses number First pulse First delay Second pulse Second delay Fluency (560nm filter) One 3 5.0 20 5.5 21 24 Two 3 5.0 20 5.5 21 23 Three 4 4.5 21 5.0 22 22 Four 4 4.0 22 4.5 23 21 Five 5 4.0 23 4.5 24 19 **If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules. 6.6 Pigmentation Therapy 1. Clear treatment area. 2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation therapy",adjust the parameter, set it to ‘ready’ . 3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4℃. 4. Wear goggles for patient and operator 5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have 1/3 overlapping on treatment area. 6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling disappears. 7.Treatment parameter: Skin Type Pulses number First pulse First delay Second pulse Page 19 Pulses number Fluency (480nm filter) Fluency (530nm filter) One 3 5.0 20 5.5 21 28 29 Two 3 5.0 20 5.5 21 27 28 Three 4 4.5 21 5.0 22 26 27 Four 4 4.0 22 4.5 23 25 26 Five 5 4.0 23 4.5 24 24 25 **If spot size 15x50mm, the fluency should be increased by 2 to 3 Joules. 6.7 Vascular Therapy 1. Clear treatment area. 2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the parameter, set it to ‘ready’ . 3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4℃. 4. Wear goggles for patient and operator 5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have 1/3 overlapping on treatment area. 6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling disappears. 7.Treatment parameter: Skin Type Pulses number First pulse First delay Secon d pulse Pulses number Fluency (580nm filter) One 3 5.0 20 5.5 21 25 Two 3 5.0 20 5.5 21 24 Three 4 4.5 21 5.0 22 23 Four 4 4.0 22 4.5 23 22 Five 5 4.0 23 4.5 24 20 ** If application for thin veins beneath the skin, the fluency can be reduced by 1 to 2 Joules ** If application for thick veins beneath the skin, the fluency can be increased by 1 to 2 Joules ** If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules. 6.8 Acne Therapy 1. Clear treatment area. Page 20 2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the parameter, set it to ‘ready’ . 3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4℃. 4. Wear goggles for patient and operator 5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have 1/3 overlapping on treatment area. 6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling disappears. 7.Treatment parameter: Skin Type Pulses number First pulse First delay Secon d pulse Pulses number Fluency(430nm filter) One 3 5.0 20 5.5 21 25 Two 3 5.0 20 5.5 21 24 Three 4 4.5 21 5.0 22 23 Four 4 4.0 22 4.5 23 22 Five 5 4.0 23 4.5 24 20 **If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules. 6.9 Wrinkle removal 1. Clear treatment area. 2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the parameter, set it to ‘ready’ . 3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4℃. 4. Wear goggles for patient and operator 5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have 1/3 overlapping on treatment area. 6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling disappears. 7.Treatment parameter: Skin Type Pulses number First pulse First delay Second pulse Second delay Fluency (560nm filter) One 3 5.0 20 5.5 21 24 Two 3 5.0 20 5.5 21 23 Three 4 4.5 21 5.0 22 22 Page 21 Four 4 4.0 22 4.5 23 21 Five 5 4.0 23 4.5 24 19 **If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules. 6.10 After Treatment care 1. Untoward Reactions:Pain, Scab formation, Pigmentation change, Scar formation, Swelling and Erythema. 2. Protect treated skin from exposure to the sunlight or irradiation of ultraviolet radiation. 3. DO NOT use irritative cosmetics within 24 hours. 4. Wash face with clean water, use moisture cosmetic when necessary. 5. Don’t eat piquant food. 6. Take Vc or VE 6.11 RF Treatment 1, Remove the cosmetic, clean treatment area. 2, Take picture of treatment area before treatment; 3, Set proper parameter on screen. Usually use 5, and choose continuous or pulse, according to different customer’s feeling. 4, Make the unit ready for treatment by press ‘ready’ button on the screen. 5, Put on the gel on the treatment area equally; 6, Before pressing the button on the hand-piece, make sure two electrodes on the head touch the treatment skin completely. It will be dangerous if just one electrode or part of two electrodes touch the skin. 7, Press the emitting button on the hand piece continually, move the hand piece on the treatment area slowly. 8, When you finish the treatment on one part, please loosen the emitting button on the hand piece first, and move hand piece next, the indicating lamp will off, the pulse output stops. Then change the other treatment area to operate. 6.12 Laser Treatment The first time treatment, voltage (power) is not too high (can blast is ok), after 10 minutes, treat again, repeated 2-3 times, do like this, can get the best results. start with lighter energy, close to the skin, don’t damage the skin. The second treatment in a month later, the power (voltage) may be bigger, 3rd time, power is biggest, usually, this time is the last time.second time and third time, the head can leave the skin a little distance, not too close. Wash colored tattoos: the first, use 1064nm head (Round one) wash, wash the black color, then use 532nm Page 22 head (square one) one month later, do like this, can remove all color easy. Wash colored tattoo, can use larger energy, not too fast frequency, the energy can be more than 700, after every time treatment, clean up the head carefully. When treating, the operator holding the laser handle as possible to form a 90 degree angle with the treatment site to ensure that the vertical laser light, avoid the laser energy loss reduction. Check power cable Check circuit breaker / fuse Check key switch No power Disengage the emergency cut off switch by rotating towards the direction of the arrows indicated Notify your distributor Key pads are none responsive Please contact the dealer. System failed to initialize Not enough power, please check main power supply. Please contact the dealer. Malfunction of flash lamp on the treatment head The treatment head / flash lamp has reached its maximum life span (100,000) shots. Replace the treatment head The E-light treatment head is probably damaged, please change the treatment head or contact the dealer. The treatment head is leaking The treatment head is probably damaged, please change the treatment head or contact the dealer. The treatment handle is warm The system is designed for continued used for up four hours in optimal environmental temperature and humidity. Always place the system on standby mode while awaiting treatment. The system might have been left on for an extended period. Turn the unit off, let it cool down for half an hour then re- start Contact the dealer. The power of The treatment head has weakened The treatment head has nearly reached its maximum life span (100,000 shots) the fluence can be adjusted by a few joules to compensate. Chapter 8 Maintenance 1. Please change the distilled or pure water every 2-3 month to keep the water tank clean Page 23 and make sure water circulation well. 2. Please get water out from the unit before moving it for long distance, e.g. from one city to another. 3. Clean the main host. 4.Clear Sapphire Crystal right after each treatment. 5. Clear filter right after each treatment, and put into the box. 6 Replace the treatment hand-piece at a appropriate time(maximum life 100000 shots). Page 24