ROMOLD Tendertext PE-Cable Chamber 03/2008 CABLE CHAMBERS .................................................................................................................................................. 2 WATERTIGHT CABLE CHAMBER ................................................................................................................................. 2 Pos. 1: Assembly and installation advices ............................................................................................................ 2 CABLE CHAMBER DN 625 .......................................................................................................................................... 2 Pos. 1: Cable chamber DN 625 ........................................................................................................................... 2 CABLE CHAMBERS DN 800 ....................................................................................................................................... 2 Pos. 1: Cable chamber DN 800, H= 44 cm .......................................................................................................... 2 Pos. 2: Cable chamber DN 800, H= 115 cm ....................................................................................................... 2 CABLE CHAMBERS DN 1000 ..................................................................................................................................... 3 Pos. 1: Cable chamber DN 1000, H= 53 cm ........................................................................................................ 3 Pos. 2: Cable chamber DN 1000, H= 110 cm ...................................................................................................... 3 Pos. 3: Cable chamber DN 1000, H= 140 cm ...................................................................................................... 3 CABLE CHAMBER DN 450 ......................................................................................................................................... 4 Pos. 1: Cable chamber DN 450 with PE-Cover ................................................................................................... 4 INLET SEALS ............................................................................................................................................................... 5 Pos. 1: Inlet seal od 32 ......................................................................................................................................... 5 Pos. 2: Inlet seal od 40 ......................................................................................................................................... 5 Pos. 3: Inlet seal od 50 ......................................................................................................................................... 5 Pos. 4: Inlet seal od 63 ......................................................................................................................................... 5 Pos. 5: Inlet seal od 75 ......................................................................................................................................... 5 Pos. 6: Inlet seal od 90 ......................................................................................................................................... 5 Pos. 7: Inlet seal od 110 ....................................................................................................................................... 5 Pos. 8: Inlet seal od 125 ....................................................................................................................................... 5 Pos. 9: Inlet seal od 160 ....................................................................................................................................... 5 COVERS DN 625 ........................................................................................................................................................ 6 Pos. 1: PE-Cover DN 625, "accessible" ............................................................................................................... 6 Pos. 2: Cover DN 625, cl. B "watertight" ............................................................................................................. 6 Pos. 3: Cover DN 625, cl. D "watertight" ............................................................................................................ 6 Pos. 4: Concrete load-distribution ring with radial seal ...................................................................................... 6 Pos. 5: PE-Construction site cover DN 625, "accessible", yellow ....................................................................... 6 COVERS 700 X 700 ..................................................................................................................................................... 6 Pos. 1: Cover 700x700 cl. B 125 .......................................................................................................................... 7 Pos. 2: Cover 700x700 cl. D 400 .......................................................................................................................... 7 1 ROMOLD Tendertext PE-Cable Chamber 03/2008 Cable chambers watertight cable chambers made of polyethylene Pos. 1: Assembly and installation advices: Delivery and installation of PE cable chambers according to the general standards. All earthworks have to be calculated including excavation, levelling and accurate backfilling. Please be advised to use plies of cohesionless material for levelling ( H => 10 cm) and backfilling. Every connection of cable conduit has to be absolutely watertight during this process. In case of using a not-watertight cover, the chamber bottom must be opened up in order to ensure dripping draining of the cable chamber. (Please follow the detailed assembly and installation advices of the particular manufacturer). Cable chamber DN 625 Pos. 1: Cable chamber DN 625, H= 80 cm PE-Cable chamber DN 625, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), horizontal reinforcement rings to secure uplift retention. Height: 45 - 80 cm Type: KS 63/80 System ROMOLD or equal Cable chamber DN 800 Pos. 1: Cable chamber DN 800, H = 44 cm PE-Cable chamber DN 625, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), internal height 44 cm, cone ID 625, horizontal reinforcement rings to secure uplift retention, height: 47 cm. Note: for buried installation Type: KS 80.63/44 System ROMOLD or equal Cable chamber DN 800 Pos. 2: Cable chamber DN 800, H = 115 cm PE-Cable chamber DN 800, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), flat and corrugated bottom, with corrosionresistant steps, vertical step distance 25 cm, cone ID 625, horizontal reinforcement rings to secure uplift retention. Height: 90 - 115 cm. Type: FC 80.63/115 SBS System ROMOLD or equal 2 ROMOLD Tendertext PE-Cable Chamber 03/2008 Cable chamber DN 1000 Pos. 1: Cable chamber DN 1000, H = 53 cm PE- Cable chamber DN 1000, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), flat and corrugated bottom, cone ID 625, horizontal reinforcement rings to secure uplift retention. Height: 53 cm. Type: KS 100.63/53 System ROMOLD or equal Cable chamber DN 1000 Pos. 2: Cable chamber DN 1000 H = 70 cm PE-Cable chamber DN 1000, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), flat and corrugated bottom, with corrosion-resistant steps, vertical step distance 25 cm, cone ID 625, horizontal reinforcement rings to secure uplift retention. Height: 60 - 70 cm. Type: KS 100.63/70 System ROMOLD or equal Cable chamber with steps DN 1000 Pos. 1: Cable chamber with steps DN 1000 H = 110 cm PE-Cable chamber DN 1000, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), flat and corrugated bottom, with corrosion-resistant steps, vertical step distance 25 cm, cone ID 625, horizontal reinforcement rings to secure uplift retention. Height: 100 - 110 cm. Type: KS 100.63/110 SBL System ROMOLD or equal Cable chamber with steps DN 1000 Pos. 2: Cable chamber with steps DN 1000 H = 140 cm PE-Cable chamber DN 1000, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), flat and corrugated bottom, with corrosion-resistant steps, vertical step distance 25 cm, cone ID 625, horizontal reinforcement rings to secure uplift retention. Height: 115 - 140 cm. Type: FC 100.63/140 SBL System ROMOLD or equal 3 ROMOLD Tendertext PE-Cable Chamber 03/2008 Cable chamber DN 450 Pos. 1: Cable chamber DN 450 H = 25 cm PE-Cable chamber DN 450, watertight, 100% virgin material without recycling content (ultimate elongation respectively elongation at tear ≥ 200 %), with reinforced bottom. Including accessible PE-Cover and EPDM-Seal for shift-free installation. Suitable to buried installation. Height (including cover): 25 cm Type: F 45/20 LD System ROMOLD or equal 4 ROMOLD Tendertext PE-Cable Chamber 03/2008 Pos. 1: Inlet seal od 32 mm Elastomer lip seal od = 32 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 32 mm, material: SBR Type: IS 32 Pos. 2: Inlet seal od 40 mm Elastomer lip seal od = 40 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 40 mm, material: SBR Type: IS 40 Pos. 3: Inlet seal od 50 mm Elastomer lip seal od = 50 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 50 mm, material: SBR Type: IS 50 Pos. 4: Inlet seal od 63 mm Elastomer lip seal od = 63 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 63 mm, material: SBR Type: IS 63 Pos. 5: Inlet seal od 75 mm Elastomer lip seal od = 75 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 75 mm, material: SBR Type: IS 75 Pos. 6: Inlet seal od 90 mm Elastomer lip seal od = 90 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 90 mm, material: SBR Type: IS 90 Pos. 7: Inlet seal od 110 mm Elastomer lip seal od = 110 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 110 mm, material: SBR Type: IS 110 Pos. 8: Inlet seal od 125 mm Elastomer lip seal od = 125 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 125 mm, material: SBR Type: IS 125 Pos. 9: Inlet seal od 160 mm Elastomer lip seal od = 160 mm, according to EN 681 and DIN 4060, for a flexible connection of pipes od = 160 mm, material: SBR Type: IS 160 5 ROMOLD Tendertext PE-Cable Chamber 03/2008 Covers DN 625 Pos. 1: PE-Cover DN 625, "accessible", watertight PE-Cover „accessible“ DN 625, round, without ventholes, incl. EPDM-seal, with two integrated handholds, for direct, shift-free assembly on PE-Chamber ID 625, construction height: 3 cm. Type ROMOLD, or equal Pos. 2: Cover DN 625, cl. B "watertight" Cover class B 125 "watertight", DN 625, round, according to EN 124, without ventholes, lid concrete-cast iron, lockable, for direct, shift-free assembly on PE-Chamber ID 625, construction height: 4 cm. Type ROMOLD, or equal Pos. 3: Cover DN 625, cl. D "watertight" Cover class D 400, DN 625, according to DIN 19584/EN 124, watertight with 4 interlocking bolts, lid cast iron, for direct, shift-free assembly on road foundation, construction height: 13 cm. Type ROMOLD, or equal Pos. 4: Concrete load-distribution ring with radial seal Load-distribution ring made of reinforced concrete B25, outer diameter 1050 mm, clear opening 665 mm, construction height 160 mm, including radial seal to seal the space among the ROMOLD PE-Chamber and the ROMOLD concrete load-distribution ring cl. D 400, including 2 screw sleeves M 12, with shifting prevention to take up a commercial cover cl. D 400, according to DIN 19584. Type ROMOLD, or equal Pos. 5: PE-Construction site cover DN 625, „accessible“, yellow PE-Construction site cover „accessible“ DN 625, round, without ventholes, with two integrated handholds, for direct, shift-free assembly on PE-Chamber ID 625 during the construction period, colour: bright yellow Type ROMOLD, or equal 6 ROMOLD Tendertext PE-Cable Chamber 03/2008 ABDECKUNGEN 700 x 700 Pos. 1: Cover 700x700 class B 125 Cover 700x700, lid cast-iron, class B 125, according to EN 124, without ventholes, cover with corrugated surface, without installation for dirt trap, clear opening 700x700 mm with supporting frame made of concrete, outer dimension: 1050x1050 mm, inner dimension: 745x745 mm, thickness: 150 mm, for shift-free assembly of cast iron covers 700x700 mm, class B 125 with PECover ‚LK 63’, DN 625, incl. Seal ‚ES 63 K’, suitable for ROMOLD PE-Chambers ID 625 LEB 70/70 G + LK 63 + ES 63 K + supporting frame made of concrete Type ROMOLD, or equal Pos. 2: Cover 700x700 class D 400 Cover 700x700, lid cast-iron, class D 400, according to EN 124, without ventholes, cover with corrugated surface, without installation for dirt trap, clear opening 700x700 mm with supporting frame made of concrete, outer dimension: 1050x1050 mm, inner dimension: 745x745 mm, thickness: 150 mm, for shift-free assembly of cast iron covers 700x700 mm, class B 125 with PECover ‚LK 63’, DN 625, incl. Seal ‚ES 63 K’, suitable for ROMOLD PE-Chambers ID 625 LEB 70/70 G + LK 63 + ES 63 K + supporting frame made of concrete Type ROMOLD, or equal 7