WAGNER PRODUCTS CORP -- CLR

advertisement
WAGNER PRODUCTS CORP
-- CLR-8 RADIANT LEAK DETECTOR
=======================================================
MSDS Safety Information
=======================================================
FSC: 6850
NIIN: 00-621-1820
MSDS Date: 01/01/1994
MSDS Num: BTWQR
Product ID: CLR-8 RADIANT LEAK DETECTOR
MFN: 01
Responsible Party
Cage: WAGNE
Name: WAGNER PRODUCTS CORP
Address: 5190 NW 165TH STREET
Box: 4647
City: MIAMI FL 33014
Info Phone Number: 305-620-6060/FAX305-623-5457
Preparer's Name: V. BAYNETT
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Cage: 2P783
Name: WAGNER PROD, CORP.
Address: 5190 N.W. 165TH STREET
City: MIAMI, FL 33014
Country: UA
Phone: UNKNOWN
Cage: WAGNE
Name: WAGNER PRODUCTS CORP.
Address: 5190 N.W. 165TH ST.
Box: 4647
City: MIAMI FL 33014
Phone: 305-477-4028-FAX
=======================================================
Item Description Information
=======================================================
Item Manager: S9G
Item Name: LEAK TEST COMPOUND
Specification Number: MIL-L-25567D
Type/Grade/Class: TYPE I
Unit of Issue: BT
Quantitative Expression: 00000000004OZ
UI Container Qty: 0
Type of Container: BOTTLE
=======================================================
Ingredients
=======================================================
Name: PER MSDS:CONTAINS NO HAZ INGRED UNDER SARA TITLE III SEC 313.
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
----------------------------Name: NON-IONIC DETERGENT
% Wt: UNK
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: UNKNOWN
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHAL:NO KNOWN EFFECTS. SKIN:MINIMAL EFFECTS ON
SKIN.
EYE:MILD STINGING SENSATION. INGEST:NAUSEA, VOMITING, MILD STOMACH
DISORDERS.
Explanation Of Carcinogenicity: PER MSDS NOT CARCINOGENIC PER
NTP/IARC/OSHA.
Signs And Symptions Of Overexposure: NAUSEA, VOMITING, MILD STOMACH
DISORDERS.
SMILD STINGING EYE SENSATION.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MFG.
First Aid: EYE/SKIN:FLUSH WITH ADEQUATE WATER. INHAL:MOVE TO FRESH AIR
IF
NECESSARY. INGEST:GIVE LUKEWARM WATER. OBTAIN EMERGENCY MED ATTN.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: GATHER UP SOLIDS AN DISPOSE OF PROPERLY.
Neutralizing Agent: NONT APPLICABLE.
Waste Disposal Methods: IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.
Handling And Storage Precautions: STORE IN COOL, DRY PLACE.
Other Precautions: NONE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: NON-FLAMMABLE.
Extinguishing Media: CARBON DIOXIDE, FOAM.
Fire Fighting Procedures: NONE.
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT NECESSARY.
Ventilation: LOCAL VENTILATION REQUIREMENT.
Protective Gloves: RUBBER GLOVES.
Eye Protection: ONLY IN EXTREME CASES.
Other Protective Equipment: NONE SPECIFIED BY MFG.
Work Hygienic Practices: WASH HANDS AFTER HANDLING PRODUCT & PRIOR TO
EAT/DRINK/SMOKE.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: N1
B.P. Text: 212F,100C
Spec Gravity: 1.002
Solubility in Water: COMPLETE (TOTAL)
Appearance and Odor: FLUORESCENT YELLOW LIQUID, TYPICAL ODOR.
Percent Volatiles by Volume: 95
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE.
Materials To Avoid: STRONG ALKALIES, OXIDIERS, ALUMINUM AND OTHER
REACTIVE
METALS.
Hazardous Decomposition Products: AT ABNORMALLY HIGH TEMPERATURES
POSSIBLE
TRACE AMOUNTS OF PHOSGENE.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
Transportation Information
=======================================================
Responsible Party Cage: WAGNE
Trans ID NO: 80163
Product ID: CLR-8 RADIANT LEAK DETECTOR
MSDS Prepared Date: 01/01/1994
Review Date: 09/09/1994
MFN: 1
Multiple KIT Number: 0
Review IND: Y
Unit Of Issue: BT
Container QTY: 0
Type Of Container: BOTTLE
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
Product ID: CLR-8 RADIANT LEAK DETECTOR
Cage: WAGNE
Company Name: WAGNER PRODUCTS CORP.
Street: 5190 N.W. 165TH ST.
PO Box: 4647
City: MIAMI FL
Zipcode: 33014
Label Required IND: Y
Date Of Label Review: 09/09/1994
Status Code: C
Label Date: 09/09/1994
Year Procured: 1994
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: INHAL:NO KNOWN EFFECTS. SKIN:MINIMAL EFFECTS ON
SKIN.
EYE:MILD STINGING SENSATION. INGEST:NAUSEA, VOMITING, MILD STOMACH
DISORDERS.
STORE IN COOL, DRY PLACE. FIRST AID: EYE/SKIN:FLUSH WITH ADEQUATE WA
TER.
INHAL:MOVE TO FRESH AIR IF NECESSARY. INGEST:GIVE LUKEWARM WATER.
OBTAIN
EMERGENCY MED ATTN. SPILLS:GATHER UP SOLIDS AND DISPOSE IN ACCORDANCE
WITH
LOCAL, STATE AND FEDERAL REGULATIONS.
=======================================================
Disclaimer (provided with this information by the compiling agencies):
This
information is formulated for use by elements of the Department of
Defense.
The United States of America in no manner whatsoever expressly or
implied
warrants, states, or intends said information to have any
application, use or
viability by or to any person or persons outside the Department of
Defense
nor any person or persons contracting with any instrumentality of the
United
States of America and disclaims all liability for such use. Any
person
utilizing this instruction who is not a military or civilian employee
of the
United States of America should seek competent professional advice to
verify
and assume responsibility for the suitability of this information to
their
particular situation regardless of similarity to a corresponding
Department
of Defense or other government situation.
Download