Colac Cattle Grids A new cattle grid that is easy to install. No excavation for a pit and no concrete box needed just level the site, position the grid and use gravel to build up the approaches, to clean just hose out with your firefighter, all to easy. Dimensions: Span 2120mm Width 3220mm Depth 300mm Mass 3.2 tonnes Load Rated – will take road legal weight Double width can be provided Installation: 1. Prepare an excavation between fence post 3.3m wide by 2.2m long. The floor of the excavation must be flat without high points. An excavation depth of 100mm accommodates a bedding layer 50mm thick and grid set down of 50mm. The latter minimises silting up of grid and slows traffic down. 2. Bedding material should be packing sand or fine gravel. Ensure bedding is level both directions. 3. The cattle grid is lowered onto the prepared base. Ensure that no part of the unit it sitting on any high points. 4. Backfill and compact around grid. Grade excavated road material up to the grid on each side to form a ramp. If depressions occur on these ramps with use add additional material. Rearrange fencing to suit grid width if required