Docx - Arcat

SECTION 08 36 00
OVERHEAD DOORS
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2006 - 2015 ARCAT, Inc. - All rights reserved
PART 1 GENERAL
1.1
1.2
1.3
1.4
1.5
SECTION INCLUDES
A.
Steel Sectional Overhead Doors.
B.
Aluminum Sectional Overhead Doors.
RELATED SECTIONS
A.
Section 05 10 00 - Structural Metal Framing.
B.
Section 06 10 00 - Rough Carpentry.
C.
Section 09 90 00 - Painting and Coating.
D.
Section 26 05 00 - Common Work Results for Electrical.
REFERENCES
A.
ASTM A653/A653M-03; 2003 - Standard Specification for Specification for Steel Sheet, ZincCoated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
B.
ASTM B209-04; 2004 - Standard Specification for Aluminum-Alloy Sheet and Plate.
C.
ASTM B221-02; 2002 - Standard Specification for Aluminum-Alloy Extruded Bars, Rods,
Wires, Shapes and Tubes.
SUBMITTALS
A.
Submit under provisions of Section 01 30 00.
B.
Shop Drawings: Indicate opening dimensions and required tolerances, jamb connection
details, anchorage spacing, hardware locations, installation details, and special conditions.
C.
[Product Data]: Provide information on components, application, hardware and accessories.
D.
Closeout Submittals:
1.
Operation and maintenance data.
QUALITY ASSURANCE
A.
Manufacturer Qualifications: Manufacturer shall provide an overhead door system capable
of withstanding positive and negative wind loads as required by local building code for
10,000 cycles.
B.
Installer Qualifications: Installer shall be authorized and qualified to install overhead door
08 36 00-1
systems on the type and scope of project specified.
1.6
1.7
DELIVERY, STORAGE, AND HANDLING
A.
Store products in manufacturer's unopened packaging until ready for installation.
B.
Store and dispose of all materials in accordance with federal, state and local laws.
PROJECT CONDITIONS
A.
1.8
Maintain environmental conditions (temperature, humidity and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under
environmental conditions outside manufacturer's absolute limits.
WARRANTY
A.
Provide an original of the manufacturer's limited warranty against manufacturing defect and
product workmanship.
1.
Duration: One (1) year.
PART 2 PRODUCTS
2.1
2.2
2.3
MANUFACTURERS
A.
Acceptable Manufacturer: C.H.I. Overhead Doors, which is located at: 1485 Sunrise Dr.;
Arthur, IL 61911; Toll Free Tel: 800-590-0559; Fax: (217) 543-4454;
Email:lschrock@chiohd.com; Web:www.chiohd.com
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section 01 60
00.
MATERIALS
A.
Galvanized Steel Sheet:
1.
Galvanized commercial steel, (CS type) per ASTM A653/A653M, G90 and G60
coating class.
B.
Aluminum:
1.
Extrusions: ASTM B221, alloy and temper best suited to application.
2.
Sheet: ASTM B209, alloy and temper best suited to application.
C.
Glazing:
1.
Clear 1/8 inch float glass.
2.
1/4 inch tempered glass.
3.
1/8 inch polycarbonate sheet.
4.
Insulating glass.
SECTIONAL STEEL DOORS
A.
Ribbed Pan Door Sections:
1.
Type: Deep ribbed, pan style.
2.
Material: Galvanized steel.
a.
20 gauge.
b.
24 gauge.
c.
26 gauge.
3.
Thickness: Nominal 2 inches.
08 36 00-2
4.
5.
6.
7.
8.
Rails: Tongue-and-groove.
End caps: Wrap-around cap style, 18 gauge galvanized steel, full height of section,
riveted to inside rails and face of door.
Insulation: 1-1/2 inches thick, CFC-free polystyrene.
Inside face: Vinyl, laminated to insulation.
Inside face: 27 gauge galvanized steel, attached with plastic retainer strips.
B.
Sandwich Style Door Sections:
1.
Type: Micro-grooved sandwich style.
2.
Material: Galvanized steel.
3.
Gauge: 26 gauge exterior and 27 gauge interior.
4.
Thickness: Nominal 2 inches
5.
Rails: Tongue-and-groove.
6.
End caps: Wrap-around box style, 20 gauge galvanized steel, full height of section.
7.
Insulation: 1-13/16 inches thick, CFC-free polystyrene.
8.
Insulation: Nominal 2 inches of 95 percent closed cell, foamed-in-place polyurethane
with thermal break.
C.
Aluminum Door Sections:
1.
Material: Extruded aluminum, stile and rail.
2.
Joints: Tongue-and-groove construction.
3.
Thickness: 2 inches.
4.
Stiles and rails:
a.
End stiles, bottom rail and top rail: 4 inch face width.
b.
Center stiles and intermediate rails: 2 inch face width.
D.
Operation and Construction:
1.
Electric operation.
2.
Manual push-up operation.
3.
Chain hoist operation.
4.
Track and Operating Hardware: Standard lift.
5.
Track and Operating Hardware: Vertical lift.
6.
Track and Operating Hardware: High lift.
7.
Track and Operating Hardware: Roof pitch.
8.
Track and Operating Hardware: Low headroom type.
9.
Glazed section: Full view type, aluminum framed.
10.
Exhaust ports: Aluminum, with hinged cover.
11.
Tracks: 2 inches wide, roll-formed 16 gauge galvanized steel, gauge adjusted per
design requirements. For doors up to 10 feet high, 14 gauge for doors exceeding 10
feet high.
12.
Tracks: 3 inches wide, roll-formed 13 gauge galvanized steel, with galvanized steel
mounting brackets, gauge adjusted per design requirements.
13.
Hinge and Roller Assemblies: Heavy duty hinges and adjustable roller holders of
galvanized steel, with floating hardened steel bearing rollers, located at top and
bottom of each panel, each side.
14.
Spring Counterbalance:
a.
Oil tempered torsion springs mounted on cross-header shaft supported by
galvanized steel ball bearing end plates and center carrier brackets as required.
b.
Counterbalance transferred to doors via aircraft quality braided steel lift cables.
15.
Weatherstripping:
a.
Bottom: Vinyl weatherseal, full width of door.
b.
Head and Jamb: Flexible one-piece vinyl extrusions.
16.
Lock Mechanism: Inside slide, adjustable keeper, spring activated.
17.
Lock Mechanism: Outside keyed T-handle, adjustable keeper, spring activated.
18.
Lock Mechanism: Outside cylinder, adjustable keeper, spring activated.
08 36 00-3
E.
Door Panel Configuration
1.
Rectangular Vision Lites: 6 inches by 24 inches set with silicone sealant and screws.
2.
Rectangular Vision Lites: 12 inches by 24 inches set with silicone sealant and screws.
3.
Rectangular Vision Lites: 16 inches by 34 inches set with silicone sealant and screws.
4.
Pattern: Centered, __ wide by __ high.
5.
Pattern: Left side looking out, __ wide by __ high.
6.
Pattern: Right side looking out, __ wide by __ high.
7.
Infill panels: Aluminum sheet, 16 gauge, located at bottom section.
8.
Infill panels: Aluminum sheet, 16 gauge, located at top section.
9.
Infill panels: Aluminum sheet, 16 gauge, located at all sections.
10.
Vision lites: Full width and height of each door section set with silicone sealant and
plastic glazing strips.
11.
Vision lites: Full width and height of each door section, excluding bottom section set
with silicone sealant and plastic glazing strips.
F.
Electric Operator:
1.
Type: Externally mounted on drive side of door.
2.
Power supply: 115 Volts AC.
3.
Power Supply: 220 Volts AC.
4.
Power Supply: 440 Volts AC.
5.
Manually operable in case of power failure.
6.
Control Station: 24 Volt Keyed Switch.
7.
Control Station: 24 Volt two button (Open / Close) station.
8.
Control Station: 24 Volt three button (Open / Stop / Close) station.
G.
Safety Reversing Edge:
1.
Photoelectric Sensor: Detect obstruction and reverse door without requiring door to
contact obstruction.
2.
Electric Edge, Two Wire: Detect obstruction and reverse door upon contact with
electric strips in vinyl housing.
3.
Electric Edge, four wire, fail-safe, self monitoring: Detect obstruction and reverse door
upon contact with electric strips in vinyl housing.
4.
Pneumatic Reversing Edge. Pressure sensitive air switch attached to gum rubber
hose located in bottom astragal of door section.
H.
Finish:
1.
Exterior panel surfaces: Baked-on enamel primer and polyester finish coat.
a.
Color: To be selected from manufacturer's standards.
2.
Interior panel surfaces: Baked-on polyester primer.
3.
Exterior panel surfaces: Clear anodized.
4.
Exterior panel surfaces: Baked-on enamel primer and white polyester finish coat.
PART 3 EXECUTION
3.1
3.2
EXAMINATION
A.
Do not begin installation until work areas have been properly prepared.
B.
If preparation is the responsibility of another installer, notify Architect of unsatisfactory
conditions before proceeding.
INSTALLATION
A.
Install door assembly in accordance with manufacturer's instructions.
B.
Anchor to adjacent construction without distortion or stress.
08 36 00-4
3.3
C.
Securely brace door tracks suspended from structure. Secure tracks to structural members
only.
D.
Fit and align door assembly including hardware, level and plumb, to provide smooth
operation.
E.
Position head and jamb weatherstripping to contact door sections when closed; secure in
position.
F.
Make wiring connections between power supply and operator and between operator and
controls.
ADJUSTING
A.
3.4
Adjust to operate smoothly throughout full operating range.
PROTECTION
A.
Protect installed products until completion of project.
B.
Touch-up, repair or replace damaged products before substantial completion.
END OF SECTION
08 36 00-5