SUPPLEMENTAL DATA Table S1. Classification of Aortitis Noninfectious aortitis Large-vessels vasculitis GCA (Giant cell arteritis) Takayasu arteritis Rheumatoid arthritis SLE (Systemic lupus erythematosus) HLA-B27 associated spondyloarthropathies Medium and small vessel vasculitis ANCA-associated vasculitides Wegener arteritis Polyarteritis nodosum Microscopic polyangiitis Behçet disease Cogan syndrome Relapsing polychondritis Sarcoidosis Idiopathic conditions Idiopathic aortitis Inflammatory aortic aneurysm (IgG4) Idiopathic retroperitoneal fibrosis (periaortitis) Radiation-induced aortitis Infectious aortitis Bacterial (salmonella, staphylococcus, streptococcus...) Viral (HIV or AIDS) Mycobacterial (mycobacterium tuberculosis) Syphilitic Mycotic aortic aneurysm Aortic graft infections Source: Gornik HL et al, 2008 [1]. PET/CT protocol and images acquisition In the framework of a prospective study supported by an EC FP7 grant, a PET/CT was performed in almost all patients referred to our department of Cardiovascular Surgery with a known aortic disease. PET/CT data were acquired in 2 hospitals, using either a Gemini BB (16-slice CT, Philips) in 12 patients (CHU) and a Discovery LS (16-slice CT, GE Healthcare) in 7 patients (CHC). All patients fasted for at least 6 hours. Plasma blood glucose level was measured before administration of the tracer and was within normal limits in all cases. FDG (3.7 MBq/kg body weight) was injected through an indwelling catheter. The uptake time was 60 minutes. A low-dose CT (thickness 5mm, increment 5mm, voltage 120 kV, current 25 mA/slice) was first acquired, followed by the PET emission scan from the skull to the upper thighs (1-3 minutes per bed position depending on the scanner and patient’s body habitus). The study was completed by an arterial phase CT (thickness 2 mm, increment 1 mm, 120 keV, 100mA/slice). Data were corrected for decay, scatter, random, attenuation and reconstructed using an interactive 3D algorithm. Low-dose CT data were used for attenuation correction. The acquisition protocol was slightly different at the CHC: Continuous arterial phase CT from the skull to the upper thighs was performed (thickness 2.5mm, 120kVp, automatic adaptation of the amperage at each tube rotation optimized with indications provided by the scout view) and followed by the PET emission scan covering the same regions (4 minutes per bed position). Data were corrected for decay, scatter, random, attenuation and reconstructed by mean of ordered subset expectation maximization (OSEM) reconstruction algorithm performed with 2 iterations and 21 ordered subsets. CT raw data were used for attenuation correction. Any increased focal uptake compared with the background, was recorded as positive according to the visual analysis. Histology protocol Five µm paraffin-embedded sections were stained with hematoxylin-eosin. Immunostaining was performed in the Ventana (Roche Molecular Biochemicals) auto-stainer. Briefly, antigen retrieval was achieved with citrate/EDTA buffer and the different primary antibodies were incubated for 32 min. The revelation was performed with a specific kit for the Ventana auto-stainer (Ultra-View Universal kit, Roche) and the 3, 3’-diaminobenzidine (DAB, Dakocytomation). The different antibodies used were CD3 antibody (DakoCytomation, polyclonal, 1/300), CD20 antibody (DakoCytomation, L-20, 1/800) and CD68 antibody (DakoCytomation, KP-1, 1/1800).