(11 November 2015) CODE TABLES AND FLAG TABLES ASSOCIATED WITH BUFR/CREX TABLE B 0 01 150 Coordinate reference system Code figure 0 1 2 3 4-65534 65535 Status WGS84, as used by ICAO since 1998 ETRS89, as defined by EPSG::4258 NAD83, as defined by EPSG::4269 DHDN, as defined by EPSG::4314 Reserved Missing value Validation Validation Validation Validation Validation Validation 0 01 151 Fixed mean sea level reference datum Code figure Status N/A Validation 0 02 006 Data obtained by Code figure Status 0 Measurement Validation 1 Derivation from other data Validation Reserved Validation Missing value Validation 2-6 7 0 02 008 Type of offshore platform Code figure Status 0 Fixed platform Validation 1 Mobile offshore drill ship Validation 2 Jack-up rig Validation 3 Semi-submersible platform Validation 4 FPSO (floating production storage and offloading unit) Validation 5 Light vessel Validation Reserved Validation Missing value (or not known) Validation 6-14 15 0 03 001 Surface station type Code figure Status 0 Land station (synoptic network) Validation 1 Shallow water station (fixed to sea/lake floor) Validation 2 Ship Validation 3 Rig/platform Validation 4 Moored buoy Validation 5 Drifting buoy (or drifter) Validation 6 Ice buoy Validation 7 Land station (local network) Validation (11 November 2015) 8 Land vehicle Validation 9 Autonomous marine vehicle Validation Reserved Validation Missing value Validation 10-14 15 0 03 002 Type of humidity sensor Code figure Status 0 Psychrometer Validation 1 Capacitive (Generic) Validation 2 Capacitive Validation 3 Capacitive (Ceramic inc.Metal-oxide) (polymer) 4Resistive (Generic) Validation Validation 5 Resistive (Salt polymer) Validation 6 Resistive (Conductive polymer) Validation 7 Thermal conductivity Validation 8 Gravimetric Validation 9 Paper-metal coil Validation 10 Ordinary human hair Validation 11 Rolled hair (Torsion) Validation 12 Goldbeater’s skin Validation 13 Chilled mirror hygrometer Validation 14 Dew cell Validation 15 Optical absorption sensor Validation Reserved Validation Missing value Validation 16-30 31 0 03 003 Thermometer/hygrometer housing Code figure 0 1 2 3 4 5 6 7-14 15 Status Screen Sling/whirling Unscreened Radiation shield Aspirated (e.g. Assmann) Other shelter Handheld Reserved for future use Missing value Validation Validation Validation Validation Validation Validation Validation Validation Validation 0 03 004 Type of screen/shelter/radiation shield Code figure 0 1 2 3 4 5 6 Status Stevenson screen Marine Stevenson screen Cylindrical section plate shield Concentric tube Rectangular section shield Square section shield Triangular section shield Validation Validation Validation Validation Validation Validation Validation (11 November 2015) 7 8 9 10-14 15 Open covered lean to Open covered inverted V roof Integrated (e.g. chilled mirror) Reserved for future use Missing value Validation Validation Validation Validation Validation 0 03 008 Artificially ventilated screen or shield Code figure Status 0 Natural ventilation in use Validation 1 Artificial aspiration in use: constant flow at time of reading Validation 2 Artificial aspiration in use: variable flow at time of reading Validation Reserved Validation Missing value Validation 3-6 7 0 03 013 Type of thermometer Code figure 0 1 2 3-6 7 Status Electrical (resistance) Validation Mercury Validation Alcohol/glycol Validation Reserved Validation Missing value Validation 0 03 016 Position of road sensors Code figure 0 1 2 3 4 5 6 7 8-14 15 Status Fast lane between the wheel tracks Fast lane between the wheel tracks in the opposite direction Fast lane in the wheel tracks Fast lane in the wheel tracks in the opposite direction Slow lane between the wheel tracks Slow lane between the wheel tracks in the opposite direction Slow lane in the wheel tracks Slow lane in the wheel tracks in the opposite direction Reserved Missing value Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation 0 03 017 Extended type of station Bit No. 1 2 3 4 5 All 6 Status Automatic Manned Event triggered Longer time period than the standard Reserved Missing value Validation Validation Validation Validation Validation Validation 0 03 018 Type of road Code figure Status (11 November 2015) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14-19 20 21 22 23 24 25 26 27-30 31 Free track without further information Free track, embankment Free track, flat relative to surroundings Free track, water basin(s) in vicinity Free track, forest Free track, cleft Free track, on hilltop Free track, on hilltop, forest Free track, in valley Free track, in valley, forest Free track, north inclination Free track, north inclination, forest Free track, south inclination Free track, south inclination, forest Reserved Bridge without further information Bridge across a valley in a urban area Bridge across a valley with forest/meadows/fields Bridge across street/track Bridge across big river/canal Bridge across river/canal of medium size Bridge across a small stream/loading canal Reserved Missing value Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation 0 03 019 Type of construction Code figure 0 1 2 3 4 5 6 7-14 15 Status Asphalt Concrete Concrete construction Steel-girder construction Box girder bridge Orthotrope slab Drain asphalt Reserved Missing value Validation Validation Validation Validation Validation Validation Validation Validation Validation 0 03 020 Material for thermometer/hygrometer housing Code figure 0 1 2 3 4-6 7 Meaning Status Wood Metal alloy Plastic/GRP Reed/grass/leaf Reserved for future use Missing value Validation Validation Validation Validation Validation Validation 0 03 021 Hygrometer heating Code figure 0 1 2 3 Meaning Unheated Heated Not applicable Missing value Status Validation Validation Validation Validation (11 November 2015) 0 03 022 Instrument owner Code figure 0 1 2 3-6 7 Meaning Status National hydro meteorological/weather service Other Standards institute Reserved for future use Missing value Validation Validation Validation Validation Validation 0 03 023 Configuration of louvers for thermometer/hygrometer screen Code figure 0 1 2 3 4 5 6 7 Meaning Status Single v section louvers Overlapping louvers Double v section louvers Non-overlapping louvers Vented, non-louvered Not applicable Reserved for future use Missing value Validation Validation Validation Validation Validation Validation Validation Validation 0 05 070 Receiver channel Code figure 0 1 2 3 Status Mie Rayleigh Reserved Missing value Validation Validation Validation Validation 0 03 014 Type of marine hygrometer Code figure Status 0 Capacitance Validation 1 Chilled mirror Validation 2 Electric Validation 3 Hair hygrometer Validation 4 Hygristor Validation 5 Psychrometer Validation 6 Torsion Validation 7 Other Validation Reserved Validation Missing value Validation 8-14 15 0 03 015 Exposure of marine thermometer/hygrometer Code figure Status 0 Aspirated (Assmann type) Validation 1 Screen (non-ventilated, i.e. natural ventilation) Validation (11 November 2015) 2 Screen (ventilated, i.e. assisted ventilation) Validation 3 Ship's screen (property of the ship) Validation 4 Ship's sling (property of the ship) Validation 5 Unscreened Validation 6 Whirling or sling psychrometer Validation Reserved Validation Missing value Validation 7-14 15 0 08 041 Data significance Code figure Status 14 Expected error Validation 15 Representative error Validation 0 12 134 Low-level inversion flag Code figure Status 0 No inversion Validation 1 Inversion Validation 2 Reserved Validation 3 Missing value Validation 0 20 056 Cloud phase Code figure 5 Status Validation Supercooled liquid water 0 20 138 Road surface condition Code figure 0 1 2 3 4 5 6 7 8-14 15 Status Dry Moist Wet Rime Snow Ice Glaze Not dry Reserved Missing value Validation Validation Validation Validation Validation Validation Validation Validation Validation Validation 0 25 185 Encryption method Code figure Meaning Status 0 AES 256 Validation 1-254 Reserved Validation Missing value Validation 255 (11 November 2015) 0 25 187 Confidence flag Code figure 0 1 2-14 15 Meaning Status Valid Invalid Reserved Missing value Validation Validation Validation Validation 0 25 188 Method for reducing pressure to sea level Code figure 0 1 2 3 4 5-14 15 Meaning Status Pressure adjusted to mean sea level following WMO 8 Pressure adjusted to mean sea level following national practice Pressure adjusted to local water level following WMO 8 Pressure adjusted to local water level following national practice Pressure not corrected for height Reserved Missing value Validation Validation Validation Validation Validation Validation Validation 0 40 036 Lidar classification type Code figure 0 1 2-14 15 Status Clear Cloud Reserved Missing value Validation Validation Validation Validation