Proposal to add optional [FYI] component to EDOS Comment #112 As a result of discussion on 10/8/2013 ballot recon call, motion to adopt profile architecture of LRI, LOI (no vote yet) Premise – “core” eDOS should cover minimum information required for a consumer to locate, select, and order a test. The use of an optional profile is to define how creators and consumers can elect to send additional content that is purely informational/educational in nature; it use is restricted to educational purposes. As this started with reference ranges, the following example uses that datatype discussion to create the initial profile. In this particular case, the following changes are proposed: 1) Create the profile and clearly define its intent: 1.1.1.1 EDOS_????_COMPONENT – ID: 2.16.840.1.113883.9.ZZ This optional component indicates support for the exchange of additional information that is informative in nature where the information may be of use to the consuming system but is not required in an order. This component provides a predetermined template for additional content in a common model to facilitate implementation across systems. This profile currently provides guidance on the exchange of the following: Reference Range Information Allows the exchange of the various reference ranges that may apply to the interpretation of a test result. Note that reference ranges communicated in the eDOS cannot be used for evaluation of actual results. OM2 – OM2.6, .7, .8 are RE RFR – Reference Range - RFR.2, .3, .6 … 2) Apply the following changes to the OM2 Segment, fields .6, .7, .8 TABLE ERROR! NO TEXT OF SPECIFIED STYLE IN DOCUMENT.-1. OM2 – NUMERIC SEQ Element Name DT Usage Cardinality Value Set Comment OBSERVATION 1 Sequence Number Test/Observation Master File NM R [1..1] 2 Units of Measure CWE_CRE RE [0..1] 3 Range of Decimal Precision O 4 Corresponding SI Units of Measure O 5 SI Conversion Factor O The first occurrence of this segment shall be valued “1”. 9999 TABLE ERROR! NO TEXT OF SPECIFIED STYLE IN DOCUMENT.-1. OM2 – NUMERIC SEQ Element Name DT Usage Cardinality Value Set Comment OBSERVATION 6 Reference (Normal) Range for Ordinal and Continuous Observations RFR Varies [0..*] eDOS_????_Component Usage: RE All other profiles Usage: O 7 Critical Range for Ordinal and Continuous Observations RFR Varies [0..*] eDOS_????_Component Usage: RE All other profiles Usage: O 8 Absolute Range for Ordinal and Continuous Observations RFR Varies [0..*] eDOS_????_Component Usage: RE All other profiles Usage: O 9 Delta Check Criteria O 10 Minimum Meaningful Increments O 2) Apply changes to the RFR datatype, fields 2, 3, 6, … (note the changes below are for illustration purposes, the actual values and field data types must be resolved per the original ballot comment). 1.2 RFR – Reference Range NOTE: reference ranges exchanged in an eDOS are NOT to be used for evaluation of results. TABLE ERROR! NO TEXT OF SPECIFIED STYLE IN DOCUMENT.-2. RFR – SEQ Component DT Usage Value SetRANGE Comments REFERENCE Name 1 Numeric Range NR R 2 Administrative Sex TBD Varies 3 Age Range TBD Varies 4 Gestational Age Range O 5 Species O 6 Race/subspecies CE Varies 7 Conditions TX O HL70001 eDOS_????_Component Usage: RE All other profiles Usage: O eDOS_????_Component Usage: RE All other profiles Usage: O HL70005 eDOS_????_Component Usage: RE All other profiles Usage: O This data type is used in OM2-6, OM2-7, and OM2-8. The eDOS IG treats RFR.6 as a CE data type by defining the format for the component, This component shall use the HL7 2.7.1 User-defined Table 0005 - Race.