Highway Reno traffic products CTC, Inc., distributes traffic products designed to meet public agency specifications for equipment used to control vehicle and pedestrian traffic on public roadways in North America. CTC distributes the following product lines: (NOTE: Please hyperlink each of these product categories to the appropriate page.) CTC highway products Reno A&E traffic products On the Reno page: Reno traffic product categories include: (NOTE: Please hyperlink each of these product categories to the appropriate page.) • Access products •Traffic products Reno traffic products include: (NOTE: Please hyperlink each of these product categories to the appropriate section.) • Bus interface units • Card racks • DC isolator • Detectors (rack mount) • Detectors (shelf mount) • Flashers • Harnesses • Load switches • Monitors • Power supplies • Switch panels • Test equipment • Transfer relays Detectors (shelf mount) U Series The U series detectors are four channel detectors with full featured LCD interface. •Meets or exceeds NEMA TS 1 specification •Patented audible detect signal on all versions •Directional logic capability •Auxiliary connector allows Phase Green input for each channel Ordering information: Model U-1200-z* z = R: Relay outputs SS: Solid-state outputs Includes programmable options 1-5 and 9-12 *Requires 804 series harness. Harness 415-2104-10 required for Phase Green inputs NOTE: Insert this hyperlinked title under “Data Sheet” • U series data sheet Insert these hyperlinked titles and documentation under “Other docs” • U series operating instructions U series manual T-100 Series The T-100 series detectors are one channel detectors with DIP switch user interface. •NEMA TS1 compatible •Patented audible detect signal on all versions Ordering information: Model T-100-z* z = R: Relay outputs SS: Solid-state outputs *Requires two 801 series harnesses Insert these hyperlinked titles and documentation under “Data sheet” • T-100 series data sheet Insert these hyperlinked titles and documentation under “Other docs” • T-100 series operating instructions T-100 series manual T-110 Series The T-110 series detectors are one channel detectors with DIP switch user interface. •NEMA TS1 compatible •Patented audible detect signal on all versions •Call delay and Call extension Ordering information: Model T-110-z* z = R: Relay outputs SS: Solid-state outputs *Requires 801 series harness Insert these hyperlinked titles and documentation under “Data sheet” • T-110 series data sheet Insert these hyperlinked titles and documentation under “Other docs” • T-110 series operating instructions • T-110 series manual T-210 Series The T-210 series detectors are two channel detectors with DIP switch user interface. •NEMA TS1 compatible •Patented audible detect signal on all versions •Call delay and Call extension Ordering information: Model T-210-z* z = R: Relay outputs SS: Solid-state outputs *Requires two 801 series harnesses Insert these hyperlinked titles and documentation under “Data sheet” • T-210 series data sheet Insert these hyperlinked titles and documentation under “Other docs” • T-210 series operating instructions • T-210 series manual T-400 Series The T-400 series detectors are four channel detectors with DIP switch user interface. •NEMA TS1 compatible •Patented audible detect signal on all versions •Call delay and Call extension Ordering information: Model T-400-z* z = R: Relay outputs SS: Solid-state outputs *Requires 804 series harness Insert these hyperlinked titles and documentation under “Data sheet” • T-400 series data sheet Insert these hyperlinked titles and documentation under “Other docs” • T-400 series operating instructions • T-400 series manual Flashers FL-200 The Model FL-200 Flasher is designed to meet or exceed NEMA Standards TS 1-1994 and TS 2-1998 and is compatible with Type 170 installations. Model FL-200 Flashers are dual circuit, solid state devices that are constructed with extruded aluminum exterior components that promote rapid heat dissipation to ensure lower operating temperatures and dependable long term operation. All internal components are readily accessible to facilitate replacement. Insert these hyperlinked titles and documentation under “Data sheet” • Model FL-200 data sheet Harnesses Model 801 10-pin harness Connector: MS-3106A-18-1S (10 pin) Length: 4, 6, or 8 feet Wire size: #22 AWG Wire type: MIL-W-16878/17 Type B/N Outer jacket: PVC (gray) Termination: None Twisted wires: Pins D and E (red and orange) loop wires Reno A&E P/N: 801-4 (4-ft. length) 801-6 (6-ft. length) 801-8 (8-ft. length) Insert these hyperlinked titles and documentation under “Data sheet” • Harness data sheet Model 804 19-pin harness Connector: MS-3106A-22-14S (19 pin) Length: 4, 6, or 8 feet Wire size: #22 AWG Wire type: MIL-W-16878/1 Type B/N Outer jacket: PVC (black) Termination: None Twisted wires: Pins D and E (brown and white/brown) Pins F and G (red and white/red) Pins J and K (orange and white/orange) Pins L and M (yellow and white/yellow) Reno A&E P/N: 801-4 (4-ft. length) 801-6 (6-ft. length) 801-8 (8-ft. length) Insert these hyperlinked titles and documentation under “Data sheet” • Harness data sheet Model 415-2104-10: 4 Pin Harness (Phase Green Interface) Use with Models: U-1100, U-1200, and U-1300 Connector: Amp 206060-1 (4 pin) Length: 10 ft. Wire type UL 1015 Wire size: #18 AWG Termination: None Insert these hyperlinked titles and documentation under “Data sheet” • Harness data sheet Load Switches Model LS-200 The Model LS-200 load switch exceeds industry standards by featuring two LED indicators per individual circuit (one for the input, one for the output). This feature provides a means of quickly and accurately conveying information regarding the input and output states of each circuit to assist technicians in troubleshooting potential cabinet problems. Meets or exceeds NEMA Standards TS 11994 and TS 2-1998 Compatible with Type 170 installations Solid state Model LS-200 load switches are three circuit, solid state devices that are constructed with extruded aluminum exterior components that promote rapid heat dissipation to ensure lower operating temperatures and dependable, long term operation. All internal components are readily accessible to facilitate replacement. Insert these hyperlinked titles and documentation under “Data sheet” • Model LS-200 data sheet Monitors MMU-1600D Series *After purchase, this MMU can be upgraded to include Ethernet capability. The Model MMU-1600D malfunction management unit (MMU) monitors up to 16 traffic signal channels for conflicting inputs, improper sequencing, incorrect timing, and invalid voltage levels. •NEMA TS-1 (Type 12) and TS-2 compatible •Advanced diagnostic features isolate problems •Event logging provides a detailed, time-stamped record of ◦Time changes ◦Monitor resets ◦Configuration changes ◦Prior faults ◦AC line voltages ◦Signal sequence data •Unique diagnostic display mode allows viewing of the following on the front of the monitor during operation: ◦ Line voltage ◦Configuration information ◦Program card settings ◦Last 20 faults •Advanced flashing yellow arrow left turn monitoring available in the industry •Optional Ethernet support - Can be added after initial purchase ◦ Ethernet port allows communications with the monitor through a settable Ethernet network IP address. ◦Both the Ethernet port and the RS-232 port can be used at the same time • Can be upgraded to the graphics version (MMU1600G) •Software available allowing for configuration, logging, and documentation Insert these hyperlinked titles and documentation under “Data sheet” • MMU-1600D series data sheet Insert these hyperlinked titles and documentation under “Other docs” • MMU-1600D series operating instructions 1.7.19 Engineering Bulletin 020 Engineering Bulletin 021 Engineering Bulletin 022 Application Notes 002 (These are in the folder as “AN-002” etc.) Application Notes 003 Application Notes 004 Application Notes 005 MMU-1600G Series The Model MMU-1600G malfunction management unit (MMU) monitors up to 16 traffic signal channels for conflicting inputs, improper sequencing, incorrect timing, and invalid voltage levels. Includes an organic light emitting diode (OLED) display •OLED display provides readability in any light condition and functions reliably over a temperature range of -22º F to +176º F (-30º C to +80º C) • All logs can be viewed on the OLED graphic display (no computer interface needed) •All AC field voltages can be displayed on a single screen, including leakage voltages on all load switch outputs •Context sensitive ”help” system assists configuration and troubleshooting tasks •Event logging provides detailed, time-stamped records of: ◦Time changes ◦Monitor resets ◦Configuration changes ◦Prior faults ◦AC line voltages ◦Signal sequence data •Configuration wizard easily configures the monitor for most applications in just a few minutes •Optional Ethernet port - can be added after initial purchase ◦ Allows communication with the monitor through a settable Ethernet network IP address. ◦Both the Ethernet port and the RS-232 port can be used at the same time •Advanced flashing yellow arrow left turn monitoring •Operates in either Type 16 mode (sixteen channels) or Type 12 mode (twelve channels) •Compliant with the following NEMA Standards: ◦NEMA TS 2-2003 ◦NEMA TS1-1989 (Type 12 mode) •NEMA compliance certified by an independent test lab •Software available allowing for configuration, logging, and documentation Insert these hyperlinked titles and documentation under “Data sheet” • MMU-1600G series data sheet Insert these hyperlinked titles and documentation under “Other docs” • MMU-1600G series operating instructions 1.7.19 • Engineering Bulletin 019 Engineering Bulletin 020 Engineering Bulletin 021 Engineering Bulletin 022 Application Notes 002 Application Notes 003 Application Notes 004 Application Notes 005 2018 Series The Model 2018 conflict monitor is the first 170 | 2070 compatible monitor to include features that simplify monitoring of complex intersections. The 2018 provides enhanced monitoring functions, event logging capability, database management, and advanced diagnostic features. The 2018 meets the requirements set forth in Chapter 3, Section 6, of the Caltrans Transportation Electrical Equipment Specifications (TEES) dated 08/16/02. •Operates in Type 210 or Type 2010 mode •Accepts 16- and 18- channel program cards •Advanced diagnostic features isolate problems •Event logging provides detailed, time-stamped records of ◦Time changes ◦Monitor resets ◦Configuration changes ◦Prior faults ◦AC line voltages ◦Signal sequence data •Unique diagnostic display mode allows viewing of on the front of the monitor while in operation: ◦ Line voltage ◦Configuration information ◦Program card settings ◦Last 20 faults Advanced flashing yellow arrow left turn monitoring •LED signal head thresholds provide enhanced monitoring for LED indications •Software available allowing for configuration, logging, and documentation Insert these hyperlinked titles and documentation under “Data sheet” • 2018 series data sheet Insert these hyperlinked titles and documentation under “Other docs” • 2018 series operating instructions 1.6.0 • Engineering Bulletin 004 Engineering Bulletin 005 Engineering Bulletin 006 Engineering Bulletin 010 Engineering Bulletin 011 Engineering Bulletin 012 Engineering Bulletin 025 Application Notes 001 Application Notes 002 Application Notes 004 Application Notes 005 Power Supplies N Series The N series power supply transforms an AC input source into regulated 12 or 16 VDC. •Front panel LEDs provide indications of AC input voltage and DC output voltage •Power switch controls input line voltage •Six-ft. DC output harness included •Optional wall-mount bracket available •DC output is rated for a maximum of 1.4 amp of load current Ordering information: Model N-yyyy-xxx (z)* yyyy = 120A: 120 VAC input power 240A: 240 VAC input power xxx =12D: 12VDC output power 16D: 16VDC output power z = Blank: Wall mount bracket not included Wall Mount: Wall-mount bracket included *When ordering, please specify whether or not you want the wall-mount configuration. Insert these hyperlinked titles and documentation under “Data sheet” • N series data sheet Insert these hyperlinked titles and documentation under “Other docs” • N series operating instructions Q Series The Q series power supply transforms an AC input source into unregulated 24 VDC. •Provides two or four unregulated 24 VDC outputs rated at 300mA •Each output is indicated by a super-bright LED •Outputs can be paralleled for increased current capacity •Power switch controls input line voltage •Fits all standard sized card racks Ordering information: Model Q-z (yyyy/xxxx)* z = 2: Two outputs, up to 8 channels 4: Four outputs, up to 16 channels yyyy = 120V: 120 VAC input power 240V: 240 VAC input power xxxx =50Hz: 50Hz input voltage frequency 60Hz: 60Hz input voltage frequency *When ordering, be certain that the power supply input voltage and frequency match the card rack input voltage and frequency configuration. Insert these hyperlinked titles and documentation under “Data sheet” • Q series data sheet (labeled Q2 and Q4) Insert these hyperlinked titles and documentation under “Other docs” • Q series operating instructions Q-12 | Q-24 Series The Q-12 and Q-24 power supplies are powered from 120 VAC, 50/60 Hz line voltage and provide either 12 VDC or 24 VDC at 5 amps. The input line voltage and DC output are separately fused. A single regulated output voltage is connected to eight connector pins. •Plug-in regulated power supplies rated for 5 amps continuous load •Switching design provides high efficiency •Power factor greater than 0.95 •Power switch controls AC line voltage •AC input is fuse protected •DC output is fuse protected •Input voltage - 85 to 135 VAC, 50/60 Hz •Pin connections compatible with Reno A&E Model Q-2 and Q-4 power supplies Ordering information: Model Q-yy yy = 12: provides 12 VDC output 24: provides 24 VDC output Insert these hyperlinked titles and documentation under “Data sheet” • Q-12 | Q-24 series data sheet (labeled Q2 and Q4) Insert these hyperlinked titles and documentation under “Other docs” • Q-12 | Q-24 operating instructions TS-2 The TS-2 cabinet power supply meets all NEMA TS2 2003 standards. •AC line input voltage - 85 VAC to 135 VAC, 50/60 Hz •AC input - fuse protected •Power factor correction >= 0.95 •12 VDC output - 5 amps •24 VDC output - 5 amps •DC outputs - fuse protection + LED indications •12 VAC unregulated output @ 250 mA •Line frequency square wave output •Advanced switch mode design provides high efficiency •Low conducted and radiated emissions Insert these hyperlinked titles and documentation under “Data sheet” • TS-2 data sheet Switch Panels SP-300 The SP-300 replaces a detector switch panel normally found on a cabinet door. It takes up less space than a conventionally located detector switch panel and allows easy monitoring of the detectors while they are being tested. •Designed for use in the M-6D detector rack •Conditions the call outputs of up to four, fourchannel detectors •Each channel has a three-position toggle switch that can be used to set the output of the channel to one of three states: ◦DET - Normal operation ◦OFF - Channel off ◦ON - Continuous call state •Each channel has a super-bright LED to indicate a call output to the controller Insert these hyperlinked titles and documentation under “Data sheet” • SP-300 data sheet (labeled Q2 and Q4) Insert these hyperlinked titles and documentation under “Other docs” • SP-300 operating instructions