IInnssttaallll LLVV7711 oonn TT550000,, rreeppeeaatt 22000088 TToohhookkuu NNoovv pprroocceedduurree
AA.. IInnssttaallll LLaabbVViieew
w77..11,, 66002244EE PPCCM
MCCIIAA
1. Install LabVIEW 7.1 on Thinkpad T500, XP professional
2. Install LabVIEW 7.1 Driver
3. Install DAQCard-6024E driver
4. Setup 6024E ports
5. Run Scan12.vi
BB.. IInnssttaallll U
USSBB iinntteerrffaaccee
1. Install USB GPIB, 9162
2. Install NI-DAQmx 8.6
3. Install NI USB 9162 carrier + NI USB 9211A thermometer
4. Run PIN vi
A. Install LabVIEW 7.1
20091019
1. Install LabVIEW 7.1 on Thinkpad T500, XP professional
Insert CD
“LabVIEW 7 Express
Professional Development system Windows 200/NT/XP
Click “Install LabVIEW 7.1”
Enter S/N, do complete install
S/N G11X15548
2. Install LabVIEW 7.1 Driver
Insert Driver CD Disk1,2 of 2 “Device Drivers for DATA Acquisition,
Instrument control, Motion and Vision”
Use default option
3. Install DAQCard-6024E driver
First time inserted DAQCard-6024E PCMCIA into ThinkPad T500
click 自動安裝 自動連線
it did find and install the driver automatically from network
4. Setup 6024E ports
Bring up “Measurement & Automation Explorer”
Right click “Data Neighborhood”  Create New
Setup “Traditional NI-DAQ Virtual Channel”
Right click on  add channel
Channels set are
Ach0; Analog Input; Voltage -5 to 5 V; No scaling; pin-0 Ref. single ended
Ach1; Analog Input; Voltage -5 to 5 V; No scaling; pin-1 Ref. single ended
Ach2; Analog Input; Voltage -5 to 5 V; No scaling; pin-2 Ref. single ended
Ach3; Analog Input; Voltage -5 to 5 V; No scaling; pin-3 Ref. single ended
Pin1 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-4 Ref. single ended
Pin2 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-5 Ref. single ended
Pin3 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-6 Ref. single ended
Pin4 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-7 Ref. single ended
Pin5 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-8 Ref. single ended
Pin6 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-9 Ref. single ended
Pin7 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-10 Ref. single ended
Pin8 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-11 Ref. single ended
Pin9 ; Analog Input; Voltage -5 to 5 V; No scaling; pin-12 Ref. single ended
Pin10; Analog Input; Voltage -5 to 5 V; No scaling; pin-13 Ref. single ended
Pin11; Analog Input; Voltage -5 to 5 V; No scaling; pin-14 Ref. single ended
Pin12; Analog Input; Voltage -5 to 5 V; No scaling; pin-15 Ref. single ended
SEL0; Digital I/O; Write to Line; DIO line 0; No invert line
SEL1; Digital I/O; Write to Line; DIO line 1; No invert line
SEL2; Digital I/O; Write to Line; DIO line 2; No invert line
SEL3; Digital I/O; Write to Line; DIO line-3; No invert line
Switch; Digital I/O; Write to Line; DIO line-6; No invert line
Vbias; Analog Input; Voltage -5 to 5 V; No scaling; pin-2 Ref. single ended
Vout; Analog Output; Voltage -5 to 5 V; No scaling; pin-0 Ref. single ended
5. Run Scan12.vi
Requires subs_2004.llb, put it in the same directory with Scan12.vi will do
Require data writing directory created, one location
B. Install USB interface
1. Install USB GPIB, 9162
20091031
Insert GPIB-USB-HS connector, XP offline, 硬體精靈 自動安裝
2. Install NI-DAQmx 8.6
NI-USB-9162 抓不到 driver
Need NI-DAQmx installation,
Use two CDs from PK, or find the latest from NI web site
It figures out what I need
My previous installation of Labview 7.1 had
Measurement & Automation Explorer is 3.1.1, upgrade to 4.3
3. Install NI USB 9162 carrier + NI USB 9211A thermometer
At CDF trailer using a HP E3631E GPIB ports differs
尋找儀器
4. Run PIN vi
Hammamatsu-select817outputoff&xy_oct06.vi works
Three output data file locations:
Set the Agilent +6V for LED voltage/current limit
Looping steps of 0.5 Volt, from 0 total 31 steps to 15 Volt.
Taken out USB 9162, NI 9211A
/Scan_PIN_noT.vi
In the Volt loop, taking Temp reading, feed them constants, plot a const display
Create Temperature measurement with N9291A
In DAQ two seetings on Agilent for voltage
1. In 0.5 steps
2. In 0,10,20 volt
Setting Agilent in loops for voltage step i*0.5V, current limit 0.003A ,
Setting Agilent in loops for voltage step i*5V, current limit 0.003A ,
After IV scan, try to set Agilent to 0 Volt,
In the code, read Keithley current measurement Error
After reading is done, then allow the action (the thick pink from above to below
An old Agilent does not communicate and give the following error