PREPARATION OF THIN FILMS FOR ELEMENTAL ANALYSIS OF NAIL POLISH BY WAVELENGTH DISPERSIVE X-RAY SPECTROSCOPY Supplementary Material Andrea C. McWilliams,1* Al A. Martin,2 Mike A. Levine1, Keith E. Levine1, Lauren Felder,1 Daniel J. Young,1 James M. Harrington1 1 Trace Inorganics Department, RTI International, 3040 E Cornwallis Rd., PO Box 12194, Research Triangle Park, NC 27709 2 Thermo Scientific, West Palm Beach, FL * Corresponding author: acm@rti.org, phone: 1-919-485-5520 Table S1. Nail polish samples analyzed in this study. Laboratory Replicates Country Color ID Shimmer 1 10 France Silver 2 10 Trinidad & Dark Red Tobago 3 10 USA Pink 4 5 Bulgaria Dark Blue 5 5 China Blue 6 5 Poland Yellow 7 3 Canada Blue 8 3 Turkey Neon Pink 9 3 Taiwan Bronze 10 3 Australia Dark Blue 11 3 Brazil Green Gloss 12 10 Canada Neon Pink 13 10 Australia Light Blue 14 10 Luxembourg Neon Pink 15 5 France Purple 16 5 UK Light Pink 17 5 USA Light Blue 18 3 Taiwan Dark Blue 19 3 Poland Light Pink 20 3 South Korea Neon Pink 21 3 China Black Table S2. Nail polish samples selected for ICP-OES comparability analysis. Laboratory ID Country Color Shimmer 2 Trinidad & Tobago Dark Red 4 Bulgaria Dark Blue 9 Taiwan Bronze 22 Sweden Pink 23 Finlanda Orange 24 Germany Pink 25 USA Blue 26 USA Yellow Gloss a 20 South Korea Neon Pink 27 Turkey Pink 28 USA Yellow 29 Luxembourga Green 30 Taiwan Red 31 Australia Pink 32 China Purple Sample was prepared and analyzed in duplicate. Table S3. WDXRF instrumental parameters for analysis of nail polish samples Elements kV mA Crystal Detectora Collimator Filter Mask (mm) a F, Na, Mg 30 80 AX03 FPC 0.40 None 29 Al, Si 30 50 AX03 FPC 0.15 None 29 P, S, Cl 40 60 Ge111 FPC 0.15 None 29 K, Ca, Ti 40 40 LiF200 FPC 0.15 None 29 V, Mn, Fe 40 60 LiF220 FPC 0.15 None 29 FPC: flow proportional counter. Table S4. Microwave digestion program for nail polish samples. Power (W) Ramp Time Hold Time Temp (°C) Pressure (PSI) (min) (min) 400 10 10 100 250 800 10 10 160 400 1600 10 10 180 600 Table S5. Instrumental parameters for analysis of nail polish thin films by ICP-OES Instrument setting Value RF Power 1150 W Nebulizer flow 0.70 L/min Auxiliary flow 0.50 L/min Viewing mode Axial Sample introduction system HF resistant Analysis pump rate 50 rpm Figure S1. Effect of inverting thin films on elemental analysis of Na, Ti, and Fe. Results shown for nail polish sample 14 show inversion for replicates 2, 3, and 8. Content (% W/W) 0.0500 Na 0.0400 0.0300 0.0200 0.0100 0.0000 1 2 3 4 5 6 7 Replicate 8 9 10 11 Content (% w/w) 3 Ti 2.5 2 1.5 1 0.5 0 Content (% w/w) 1 2 3 0.1600 0.1400 0.1200 0.1000 0.0800 0.0600 0.0400 0.0200 0.0000 4 5 6 7 Replicate 8 9 10 11 Fe 1 2 3 4 5 6 7 Replicate 8 9 10 11