application of spintronics - Blog Unsri

advertisement
APPLICATION OF SPINTRONICS
dear
d34r123@yahoo.co.id
KOMUNITAS BLOGGER UNIVERSITAS SRIWIJAYA
ABSTRACT THE SPINTRONIC SCANNER FOR CANCER DETECTION Spintronics is a
study that deals with spin of an electron, ("spin-based electronics") also known as
magneto-electronics, is an emergent technology which exploits the quantum property of
electrons to spin as well as making use of their charge. There are two spins (UP spin and
DOWN Spin).This spintronic scanning technique is an efficient technique used in the medical
field to detect cancer cells. Cancer cells are easy to be identified only when they are large in
number. These cells when matured results in formation of tumor, which has to be removed
by surgery. After surgery there may be presence of even a single cancer cell, which would
result in growth of tumor in effected part of the body. The spintronic scanning is an efficient
technique to detect cancer cells even when they are less in number. A Patient is exposed to
a strong magnetic field so that his body cell gets magnetized. A beam of electrons with
polarized spin is introduced on the uneffected part of the body and the change in spin is
detected by a polarimeter. A beam of electrons with polarized spin is introduced on the part
which had undergone surgery. The difference in spin of electrons when introduced to normal
area and abnormal area indicates whether cancer cells have been removed from the body. If
not, it indicates the presence of traces of cancer cells and it has to be treated again for
ensuring complete safety to the patient. Thus this technique efficiently identifies the presence
of cancer cells in that part of the body that has undergone surgery to prevent any further
development. INTRODUCTION: An emerging research field in physics focused on spindependent phenomena applied to electronic devices is called spintronics. The promise of
spintronics is based on manipulation not only of the charge of electrons, but also their spin,
which enables them to perform new functions. Currently, the ability to manipulate electron
spin is expected to lead to the development of remarkable improvements in electronic
systems and devises used in photonics, data processing and communications technologies
only. Now this paper brings out an innovative idea of extending the hands of spintronics in
MEDICAL FIELD, in the detection of cancer cells even when they are very few in number in
the human body. This approach is relied on two important aspects: · the behavior of
electron spin in a magnetic field · the cancer cell’s abnormality over normal
cells SPINTRONICS: Spintronics, or spin electronics, refers to the study of the role played by
electron spin in solid state physics, and possible devices that specifically exploit spin
properties instead of or in addition to charge degrees of freedom. In spintronics electron spin,
in addition to charge, is manipulated to yield a desired outcome. An electron is just like a
spinning sphere of charge. It has a quantity of angular momentum (its "spin") and
an associated magnetism, and in an ambient magnetic field its energy depends on how its
spin vector is oriented. Every electron exists in one of two states, namely, spin-up and spindown with its spin either +1/2 or –1/2. In other words, an electron can rotate either
clockwise or counterclockwise around its own axis with constant frequency. . Two spins can
be "entangled" with each other, so that neither is distinctly up nor down, but a
combination of the two possibilities. In order to make a spintronic device, the primary
requirement is to have a system that can generate a current of spin polarised electrons, and
a system that is sensitive to the spin polarization of the electrons. Most devices also have a
unit in between that changes the current of electrons depending on the spin states. The
simplest method of generating a spin polarised current is to inject the current through a
ferromagnetic material. The most common application of this effect is a giant
magnetoresistance (GMR) device. A typical GMR device consists of at least two layers of
ferromagnetic materials separated by a spacer layer. When the two magnetization vectors of
the ferromagnetic layers are aligned, then an electrical current will flow freely, whereas if the
magnetization vectors are antiparrallel then the resistance of the system is higher. Two
variants of GMR have been applied in devices, current-in-plane where the electric current
flows parallel to the layers and current-perpendicular-to-the-plane where the electric current
flows in a direction perpendicular to the layers. Applications Spintronic devices are used in
the field of mass-storage devices; recently (in 2002) IBM scientists announced that they
could compress massive amounts of data into a small area, at approximately one trillion bits
per square inch (1.5 Gbit/mm²) or roughly 1 TB on a single sided 3.5" diameter
disc. The storage density of hard drives is rapidly increasing along an exponential growth
curve known as Kryder\'s Law. The doubling period for the areal density of information
storage is twelve months, much shorter than Moore\'s Law, which observes that the number
of transistors in an integrated circuit doubles every eighteen months. Also the hard disk
drives use a spin effect to function, the Giant magnetoresistive effect (see below). The most
successful spintronic device to date is the spin valve. This device utilizes a layered structure
of thin films of magnetic materials, which changes electrical resistance depending on applied
magnetic field direction. In a spin valve, one of the ferromagnetic layers is
"pinned" so its magnetization direction remains fixed and the other ferromagnetic
layer is "free" to rotate with the application of a magnetic field. When the
magnetic field aligns the free layer and the pinned layer magnetization vectors, the electrical
resistance of the device is at its minimum. When the magnetic field causes the free layer
magnetization vector to rotate in a direction antiparallel to the pinned layer magnetization
vector, the electrical resistance of the device increases due to spin dependent scattering.
The magnitude of the change, (Antiparallel Resistance - Parallel Resistance) / Parallel
Resistance x 100% is called the GMR ratio. Devices have been demostrated with GMR
ratios as high as 200% with typical values greater than 10%. This is a vast improvement over
the anisotropic magnetoresistance effect in single layer materials which is usually less than
3%. Spin valves can be designed with magnetically soft free layers which have a sensitive
response to very weak fields (such as those originating from tiny magnetic bits on a
computer disk), and have replaced anisotropic magnetoresistance sensors in computer hard
disk drive heads since the late 1990s. Future applications may include a spin-based
transistor which requires the development of magnetic semiconductors exhibiting room
temperature ferromagnetism. The operation of MRAM or magnetic random access memory
is also based on spintronic principles. CANCER CELLS: Cancer cells are the somatic cells
which are grown into abnormal size. The cancer cells have different electromagnetic pattern
when compared to normal cells. For many types of cancer, it is easier to treat and cure the
cancer if it is found early. There are many different types of cancer, but most cancers begin
with abnormal cells growing out of control, forming a lump that\'s called a tumor. The tumor
can continue to grow until the cancer begins to spread to other parts of the body. If the tumor
is found when it is still very small, curing the cancer can be easy. However, the longer the
tumor goes unnoticed, the greater the chance that the cancer has spread. This makes
treatment more difficult. Tumor developed in human body, is removed by performing a
surgery. Even if a single cell is present after the surgery, it would again develop into a tumor.
In order to prevent this, an efficient method for detecting the cancer cells is required. Here, in
this paper, we introduce a new method for detecting the cancer cells after a surgery. This
accurate detection of the existence of cancer cells at the beginning stage itself ensures the
prevention of further development of the tumor. PROPERTIES OF SPIN: · The spin
of an electron has a great dependence over an external magnetic field. If a polarized electron
is exposed in a magnetic field, its spin orientation gets varied. This behavior of the electron
plays a crucial role in the presented approach in this paper. · Polarization of spin of
electrons is possible so that the spin of all electrons orient in a particular direction. ·
The electron spin can be detected by using devices like polarimeters. · The electron
spin can be controlled electrically just with the application of few volts. DETECTION OF
CANCER CELLS: It is very important that the cancer cells should be diagnosed at the earlier
stages itself failing which develop rapidly into acute tumors. AN INNOVATIVE APPROACH
TO DETECT THE CANCER CELLS WITH THE HELP OF SPINTRONICS IS PRESENTED
HERE. The following setup is used for the detection of cancer cells in a human body:
· Polarized electron source · Magnetic field · Spin detector
POLARISED ELECTRON SOURCE: A beam of electrons is said to be
“polarized” if their spins point, on average, in a specific direction. There are
several ways to employ spin on electrons and to control them. The requirement for this paper
is an electron beam with all its electrons polarized in a specific direction. The following are
the ways to meet the above said requirement: · Photoemission from negative
electron affinity GaAs · Chemi-ionization of optically pumped meta stable Helium
· An optically pumped electron spin filter A spin filter is more efficient electron
polarizer which uses an ordinary electron source along with a gaseous layer of Rb. Free
electrons diffuse under the action of an electric field through Rb vapour that has been spin
polarized in optical pumping. Through spin exchange collisions with the Rb, the free
electrons become polarized and are extracted to form a beam. To reduce the emission of
depolarizing radiation, N2 is used to quench the excited Rb atoms during the optical pumping
cycle. SPIN DETECTORS: There are many ways by which the spin of the electrons can be
detected efficiently. The spin polarization of the electron beam can be analyzed by using:
· Mott polarimeter · Compton polarimeter · Moller type polarimeter
Typical Mott polarimeters require electron energies of ~100 keV. But Mini Mott polarimeter
uses energies of ~25 keV, requiring a smaller overall design. The Mini Mott polarimeter has
three major sections: the electron transport system, the target chamber, and the detectors.
The first section the electrons enter is the transport system. An Einsel lens configuration was
used here. Two sets of four deflectors were used as the first and last lens. The electrons next
enter the target chamber. The chamber consists of a cylindrical target within a polished
stainless steel hemisphere. A common material used for the high-Z nuclei target is gold.
Low-Z nuclei help minimize unwanted scattering, so aluminum was chosen. Scattered
electrons then exit the target chamber and are collected in the detectors. Thus there are
many methods for detecting the spin polarization of electrons. EXTERNAL MAGNETIC
FIELD: An external magnetic field is required during this experiment. The magnetic field is
applied after the surgery has undergone. First, it is applied to an unaffected part of the body
and then to the surgery undergone part of the body. It is already mentioned that the magnetic
field could easily alter the polarization of electrons. APPLICATION OF SPINTRONICS IN
MEDICAL FIELD. EXPERIMENTAL SETUP: MOTT POLARIMETER OPTICAL SPIN FILTER
HUMAN BODY The procedure for doing this experiment is as follows: · After surgery
and the removal of the tumor, the patient is exposed to a strong magnetic field. ·
Now the polarized electron beam is applied over the unaffected part and spin orientation of
electrons are determined using polarimeter. · Then the same polarized beam is
targeted over the affected part of the body and from the reflected beam, change in spin is
determined. Based on these two values of spin orientation, the presence of tumor cells can
be detected even if they are very few in number. Hence, we suggest this method for the
detection purpose. A detailed view of this innovative approach is given as follows. SPIN
ORIENTATION OF THE UNAFFECTED PART OF THE BODY: APPLYING MAGNETIC
FIELD: When the magnetic field is applied to the unaffected part of the human body, the
normal somatic cells absorbs the magnetic energy and retains it. DETERMINING THE SPIN
ORIENTATION: When the electrons get incident on the cells the magnetic energy absorbed
by the cells alters the spin orientation of the electrons. These electrons get reflected and it is
detected by the Mott polarimeter. Then the change in spin orientation of the electrons is
measured as Sx. SPIN ORIENTATION OF SURGERY UNDERGONE PART OF THE BODY:
APPLYING MAGNETIC FIELD: In the surgery undergone part of the body an external
magnetic field is applied. The cancer cells which are present, if any, will absorb more
magnetic energy than the normal cells since they differ in their electromagnetic pattern.
DETERMINING THE SPIN ORIENTATION: Now an electron beam which is polarized is
incident on the surgery undergone part of the body. The magnetic energy absorbed by the
cancer cell alter the spin orientation of the electron beam. Since cancer cells absorb more
magnetic energy, the change in orientation caused by them are also more. If no cancer cells
are present the amount of change is equal to the previous case. The change in spin is
measured by the polarimeter as Sy. INFERENCE: If the change in the spin in the unaffected
part of the body is same as that of the surgery undergone part, i.e. If Sx=Sy Then, There are
no cancer cells in the surgery undergone part of the body and all the cells have been
removed by the surgery. If the change in spin in the unaffected part is not equal to the
change caused by the surgery undergone part of the body, i.e. If Sx not equals Sy Then,
There are some cancer cells in the surgery undergone part of the body and the cancer cells
are not completely removed by the surgery. CONCLUSION: Thus the usage of electron spin
in the cancer cell detection provides way for the entry of spintronics in medical field. The
approach suggested in this paper acts as an efficient way of cancer cell detection after
surgery thereby preventing the further growth of tumor cells. DOWNLOAD
Download