SECTION 054600 –STRUCTURAL & NON-STRUCTURAL BASE
SECTION 077120 – PREFINISHED COVER & PERFORATED CLOSURE
January 2010
SECTION 54600
STRUCTURAL AND NON STRUCTURAL BASE
ACS Structeavent
1
January 2010
ACS, LLC
7540 Lupre Drive
McCalla, AL. 35111
Phone: (205) 434-4974 Fax: (205) 434-4976
E-Mail: hayers@acs-reps.com Web Site: www.acs-reps.com
Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction
Specifications Institute (CSI) 3-Part Format, including Master Format, Section Format, and
Page Format, contained in the CSI Manual of Practice.
The section must be carefully reviewed and edited by the Architect to meet the requirements of the project and
local building code. Coordinate this section with other specification sections and the drawings.
Delete all “Specifier Notes” when editing this section.
SECTION 054600
COLD – FORMED METAL EAVE AND FASCIA SYSTEM
Specifier Notes: This section covers ACS “Structeavent®” structural, non-structural, vented and
non-vented eave and fascia systems. Consult ACS for assistance in editing this section for the
specific applications.
PART 1 GENERAL
1.1 SECTION INCLUDES
A.
B.
C.
D.
E.
F.
G.
H.
Structural vented eave and fascia system.
Structural vented attic eave and fascia system.
Structural non-vented eave and fascia system.
Non-Structural vented eave and fascia system.
Non-Structural vented attic eave and fascia system.
Non-structural non-vented eave and fascia system.
Gable / Rake with Zee’s.
Gable / Rake without Zee’s.
Model: SV
Model: SVA
Model: SNV
Model: NSV
Model: NSVA
Model: NSNV
Model: SGRZ, and NSGRZ
Model: SGR, and NSGR
1.2 RELATED SECTIONS
A. Roof Specialties: Manufactured Fascia Cover and Perforated Vent Closure, see Specification
section 077120
B. Other Related Sections
Specifier Notes: Edit the following list as required for the project. List other sections with work
directly related to this section.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Section 051200 - Structural Steel: Structural roof framing.
Section 052100 - Steel Joists.
Section 053100 - Steel Deck: Steel roof deck.
Section 054200 - Cold-Formed Metal Joists: Cold-formed steel trusses.
Section 061600 - Sheathing: Plywood and oriented strand board.
Section 072200 - Roof and Deck Insulation: Roof board insulation.
Section 073100 - Shingles.
Section 073200 - Roof Tiles.
Section 074100 - Metal Roof and Wall Panels: Preformed metal roofing.
ACS Structeavent
2
January 2010
10.
11.
12.
13.
Section 076200 - Sheet Metal Flashing and Trim.
Section 077120 – Roof Specialties: Manufactured Fascia and Closure
Section 077100 - Manufactured Roof Specialties: Manufactured fascia and gutters.
Section 102300 - Vents: Soffit vents.
1.3 REFERENCES
A.
ASTM A 653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron AlloyCoated (Galvannealed) by the Hot-Dip Process.
B. ASTM A 792 - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated
by the Hot-Dip Process.
1.4 DESIGN REQUIREMENTS
A. Design Loads: Design structural vented (SV) or structural non-vented (SNV) eave and
fascia system to support specified loads.
Specifier Notes: Specify the design loads.
1. Live Load: _______________
2. Dead Load: ______________
3. Diaphragm Load: _______________
B. Ventilation: Must meet or exceed the required net free air per linear foot (nfa/lf) as
determined by the vented roof deck system and eave condition as indicated on the Drawings.
1.5 SUBMITTALS
A. Comply with Section 013300 - Submittal Procedures.
B. Product Data: Submit manufacturer's product data, including installation instructions.
C. Shop Drawings: If required, submit manufacturer's shop drawings, indicating materials,
gauges, dimensions, tolerances, fasteners, mounting, and finish.
1.6 QUALITY ASSURANCE
A.
Manufacturer Qualifications: Company specializing in manufacturing Products specified
in this section with a minimum of ten years documented experience.
B.
Installer Qualifications: Company specializing in the installation of products specified or
product of a similar nature with minimum five years documented experience.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Delivery: Deliver materials to site in manufacturer's original, unopened containers and
packaging, with labels clearly identifying product name and manufacturer.
B. Storage: Store materials in clean, dry area in accordance with manufacturer's instructions.
C. Handling: Protect materials during handling and installation to prevent damage.
1.8 ENGINEERING
A.
When specified, the structural system will be sealed by an architect registered in the state.
ACS Structeavent
3
January 2010
1.9 WARRANTY
A. Provide the manufacturer’s warranty specified under products for the roof edge system, when installed
per manufacturer’s instructions. Warranty will not exceed the life of the original roof.
B. Provide 20 year, 125 mph Wind and Ventilation Warranty
C. Provide 30 year warranty for manufacturer approved 70 percent Kynar colors for the painted finish
covering color fade, chalk and film integrity.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Design Basis: Structeavent® manufactured by ACS, LLC, McCalla, AL 35111
Phone: (205) 434-4974 Fax (205) 434-4976
Email: hayers@acs-reps.com Website www.acs-reps.com
1. Approved Manufacturers

ACS, LLC., Howard Ayers 205-434-4974

Precision Fabricators of Atlanta, Greg Danford 404-965-9341

Architectural Products, Co., Michael Maier 800-837-1001
2.2 MATERIALS
A. Eave and Fascia Systems
1.
2.
3.
4.
5.
6.
7.
8.
Structural vented eave and fascia system.
Structural vented attic eave and fascia system
Structural non-vented eave and fascia system.
Non-Structural vented eave and fascia system.
Non-Structural vented attic eave and fascia system.
Non-structural non-vented eave and fascia system.
Gable / Rake with Zee’s.
Gable / Rake without Zee’s.
Model: SV
Model: SVA
Model: SNV
Model: NSV
Model: NSVA
Model: NSNV
Model: SGRZ and NSGRZ
Model: SGR and NSGR
Specifier Notes: Specify the model number(s), material, and finish.
1. Model(s): _______________
2. Base Assembly, including zees and gutter support, shall be [Galvanized steel,
ASTM A 653, G-90, Grade 40, structural quality] or [Galvalume steel, ASTM A 792, G-90,
AZ55, Grade 40, structural quality].
3. Front Cover, Galvanized Steel, (To be used when fascia is EFIS, Plaster, etc…).
4. Perforated Closure, Aluminum, (To be used when fascia is EFIS, Plaster, etc…).
** Prefinished Fascia and Prefinished Perforated Closure please reference Specification
Section 077120.
ACS Structeavent
4
January 2010
PART 3 EXECUTION
EXAMINATION
A. Examine areas to receive eave and fascia system.
B. Notify Architect if areas are not acceptable.
C. Do not begin installation until unacceptable conditions have been corrected.
3.2 INSTALLATION
A. Install eave and fascia system in accordance with manufacturer's instructions at locations
indicated on the drawings.
B. Submit product design drawings for review and approval to Architect or Specifier before
fabrication.
C. Installer shall furnish mechanical fasteners consistent with manufacturer’s instructions
suitable for the substrate to which being installed.
END OF SECTION
ACS Structeavent
5
January 2010
SECTION 077120
Prefinished Fascia and Perforated Closure
ACS Structeavent
6
January 2010
ACS, LLC
7540 Lupre Drive
McCalla, Al. 35111
Phone: (205) 434-4974 Fax: (205) 434-4976
E-Mail: hayers@acs-reps.com Web Site: www.acs-reps.com
Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction
Specifications Institute (CSI) 3-Part Format, including Master Format, Section Format, and
Page Format, contained in the CSI Manual of Practice.
The section must be carefully reviewed and edited by the Architect to meet the requirements of the project and
local building code. Coordinate this section with other specification sections and the drawings.
Delete all “Specifier Notes” when editing this section.
SECTION 077120
ROOF SPECIALTIES: MANUFACTURED FASCIA AND CLOSURE
Specifier Notes: This section covers ACS “Structeavent®” structural, non-structural, vented and
non-vented eave and fascia systems. Consult ACS for assistance in editing this section for the
specific applications.
PART 1 GENERAL
1.10
A.
B.
C.
D.
E.
F.
G.
H.
1.11
SECTION INCLUDES
Structural vented eave and fascia system.
Structural vented attic eave and fascia system.
Structural non-vented eave and fascia system.
Non-Structural vented eave and fascia system.
Non-Structural vented attic eave and fascia system.
Non-structural non-vented eave and fascia system.
Gable / Rake with Zee’s.
Gable / Rake without Zee’s.
Model: SV
Model: SVA
Model: SNV
Model: NSV
Model: NSVA
Model: NSNV
Model: SGRZ, and NSGRZ
Model: SGR, and NSGR
RELATED SECTIONS
A. Cold Formed Metal Eave and Fascia System, see Specification section 054600
B. Other Related Spec Sections
Specifier Notes: Edit the following list as required for the project. List other sections with work
directly related to this section.
1.
2.
3.
4.
5.
6.
Section 051200 - Structural Steel: Structural roof framing.
Section 052100 - Steel Joists.
Section 053100 - Steel Deck: Steel roof deck.
Section 054200 - Cold-Formed Metal Joists: Cold-formed steel trusses.
Section 054600 - Cold-Formed Metal Eave and Fascia System
Section 061600 - Sheathing: Plywood and oriented strand board.
ACS Structeavent
7
January 2010
7.
8.
9.
10.
11.
12.
13.
14.
1.12
Section 072200 - Roof and Deck Insulation: Roof board insulation.
Section 073100 - Shingles.
Section 073200 - Roof Tiles.
Section 074100 - Metal Roof and Wall Panels: Preformed metal roofing.
Section 076200 - Sheet Metal Flashing and Trim.
Section 077119 – Manufactured Gravel Stops and Fascias
Section 077100 - Manufactured Roof Specialties: Manufactured fascia and gutters.
Section 102300 - Vents: Soffit vents.
REFERENCES
C. ASTM A 653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron AlloyCoated (Galvannealed) by the Hot-Dip Process.
D. ASTM A 792 - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated
by the Hot-Dip Process.
1.13
DESIGN REQUIREMENTS
D. Ventilation: Must meet or exceed the required net free air per linear foot (nfa/lf) as
determined by the vented roof deck system and eave condition as indicated on the Drawings.
1.14
SUBMITTALS
A. Comply with Section 013300 - Submittal Procedures.
B. Product Data: Submit manufacturer's product data, including installation instructions.
E. Shop Drawings: If required, submit manufacturer's shop drawings, indicating materials,
gauges, dimensions, tolerances, fasteners, mounting, and finish.
D. Samples: Submit manufacturer's standard color chart.
1.15
QUALITY ASSURANCE
C. Manufacturer Qualifications: Company specializing in manufacturing Products specified
in this section with a minimum of ten years documented experience.
D. Installer Qualifications: Company specializing in the installation of products specified or
product of a similar nature with minimum five years documented experience.
1.7 DELIVERY, STORAGE, AND HANDLING
D. Delivery: Deliver materials to site in manufacturer's original, unopened containers and
packaging, with labels clearly identifying product name and manufacturer.
B. Storage: Store materials in clean, dry area in accordance with manufacturer's instructions.
E. Handling: Protect materials during handling and installation to prevent damage.
ACS Structeavent
8
January 2010
1.16
WARRANTY
D. Provide the manufacturer’s warranty specified under products for the roof edge system, when installed
per manufacturer’s instructions. Warranty will not exceed the life of the original roof.
E. Provide 20 year, 125 mph Wind and Ventilation Warranty
F. Provide 30 year warranty for manufacturer approved 70 percent Kynar colors for the painted finish
covering color fade, chalk and film integrity.
PART 2 PRODUCTS
2.1 MANUFACTURER
B. Design Basis: Structeavent® manufactured by ACS, LLC, Bessemer, AL. 35022
Phone: (205) 434-4974 Fax (205) 434-4976
Email: hayers@acs-reps.com Website: www.acs-reps.com
2.
Approved Manufacturers

ACS, LLC., Donnetta Ayers 205-434-4974

Precision Fabricators of Atlanta, Greg Danford 404-965-9341

Metal Roofing Solutions, Bobbie Smith 205-391-9530

Architectural Products, Co., Michael Maier 800-837-1001
2.2 MATERIALS
A. Eave and Fascia Systems
1.
2.
3.
4.
5.
6.
7.
8.
Structural vented eave and fascia system.
Structural vented attic eave and fascia system
Structural non-vented eave and fascia system.
Non-Structural vented eave and fascia system.
Non-Structural vented attic eave and fascia system.
Non-structural non-vented eave and fascia system.
Gable / Rake with Zee’s.
Gable / Rake without Zee’s.
Model: SV
Model: SVA
Model: SNV
Model: NSV
Model NSVA
Model: NSNV
Model: SGRZ, and NSGRZ
Model: SGR, and NSGR
Specifier Notes: Specify the model number(s), material, and finish.
1. Model(s): _______________
2. Prefinished Fascia: (Select), 24 ga., 22ga., galvanized steel.
Or; .032, .040, .050 Aluminum. (Custom materials by special request)
3. Prefinished Closure in 040 Aluminum: (Select), Bone White, Sandstone, Dark Bronze.
(Custom color by special request.)
4. Finish: Standard prefinished, pre-coated Kynar 500® / Hylar 5000®. As selected from
Standard colors, Pac Clad / Peterson Aluminum Color Chart. (Custom colors by special
request)
** Associated Prefabricated Base and Zee assembly contained in specification section 054600
ACS Structeavent
9
January 2010
PART 3 EXECUTION
EXAMINATION
D. Examine areas to receive eave and fascia system.
E. Notify Architect if areas are not acceptable.
F. Do not begin installation until acceptable conditions have been corrected.
3.2 INSTALLATION
D. Install fascia and closure system in accordance with manufacturer's instructions at locations
indicated on the drawings.
E. Submit product design drawings for review and approval to Architect or Specifier before
fabrication.
F. Installer shall furnish mechanical fasteners consistent with manufacturer’s instructions
suitable for the substrate to which being installed.
END OF SECTION