QUOTATION FOR SCIENTIFIC EQUIPMENTS
Selesih, the 28th August, 2015
No.P-7/CVSC/CAU/NTP/2015/ /: Sealed quotations are invited for supply of the following
scientific equipments for different Departments and veterinary hospital, College of Veterinary
Sciences & Animal Husbandry, Central Agricultural University, Selesih, Aizawl, Mizoram.
The last date of submission of quotation is 01.10.2015 at 1.00 pm and the quotations will
be opened on 01.10.2015 at 3:00pm in the Conference Hall by the college purchase committee.
(D. Kathiresan)
Dean
CENTRAL AGRICULTURAL UNIVERSITY
College of Veterinary Sciences & Animal Husbandry
Selesih, Aizawl: Mizoram
TERMS AND CONDITIONS FOR PURCHASE OF EQUIPMENT
1. Rates quoted shall clearly mention taxes/levies, packing, forwarding, freight, transit insurance,
octroi, delivery charges, installation and demonstration at College of Veterinary Sciences &
Animal Husbandry, Selesih as per quoting instructions. This Institution is exempted from
Excise & Custom duties; hence, should not be included. If necessary it may be mentioned
separately. The DSIR, Govt. of India Registration Certificate for Excise & Custom duties
exemption along with requisite documents will be provided at the time of purchase.
2. All the equipment shall be delivered in India for payment in Rupees in India. Only equipment of
reputed brands and duly registered (Registration certificate to be enclosed) shall be quoted.
Quotations for unregistered brands/assembled equipments will be summarily rejected.
3. 2 % Earnest Money deposit (EMD) forms an integral part of the tender without which the
tender will be invalid. The EMD will be returned to unsuccessful bidders after the purchase
decision is taken.
4. Copy of ISO/Quality Assurance Certificate, quality control certificate, authorized dealership
certificate/Registration certificate with DGS&D and as applicable from the manufacturer has to
be furnished. Detailed specifications for the quoted equipments should be given in the quotation
and should be supported by product brochure of the manufacturer.
5. Delivery, installation and demonstration of equipments has to be made at the Institution, which
is 12 Km. short of Aizawl, located on Aizawl-Sihphir-Silchar Road. No responsibility will be
taken to receive consignments from any other agency.
6. Consignee: Dean, College of Veterinary Sciences & A.H.(CAU), Selesih, Aizawl – 796 014,
Mizoram.
7. Rates quoted should be valid for at least one year from the last date for receipt of the
quotations. The quotations should be accompanied with manufacturer’s consumer price list in
effect for the said period & in no case should exceed the listed price. However, if there is
decrease in the manufacturer’s price on the date of supply (billing date) the same has to be
passed on to the Institution if the brand is selected for purchase based on open tender.
8. Supply must be completed within 45 days from the date of issue of supply order unless
otherwise specified; failing which the order may be cancelled.
9. No advance payment will be made prior to delivery and installation of the
equipments/appliances to the full satisfaction of the indenter.
10. The equipment/appliances should be meeting the specifications in the tender document and
any deviation in that matter may result in rejection.
11. At least one-year warranty should be provided from the date of delivery and installation and
free service should be provided at the Institution during this period, if necessary.
12. Supply will be made at supplier’s risk and any damage/breakage before the
installation/delivery has to be replaced by the supplier without any extra cost.
13. In case of poor quality and unsatisfactory operation of equipment/appliances the Institution reserves
the right to reject them at the time of delivery and installation.
14. The dealer/manufacturer has to provide manufacturer’s quality control/test certificate of each
equipment/appliances without fail at the time of supply.
15. After successful execution of a supply order payment will be made within 30 days.
16. The Institution authorities reserve the right to accept/reject any or all of the tenders received
without assigning any reason there of. In case of any dispute, the decision of the University
authorities shall be final and binding.
DECLARATION
I have gone through the above terms and conditions and agree to abide by them in the event
of receipt of a supply order from the Institution based on tender. I understand that in the event
of tender being quoted is not as per the quoting instructions; it may invite rejection of the
tender.
Date :
Place:
Signature of the Bidder
QUOTING INSTRUCTIONS.
1. No clear mentioning of packing, forwarding, freight and insurance charges in the tender will be
considered as incomplete; and will be rejected.
2. Optional accessories offered by the bidder would not be taken into consideration for the
evaluation of bid.
3. Alternate offer is not permitted. In case of quoting of more than one offer, only the lowest one
will be consider as valid one and the others will not be considered for evaluation of bid.
4. Quote must include all accessories asked for by the indenter. If the accessories are not
detailed in the product brochure it must be clearly mentioned in the tender along with their
price. Otherwise it invites rejection on the ground of incomplete quote.
5. Expected working life of the equipment is an important specification and may clearly be
mentioned in the quote for all items.
6. Only certified, legible copies of valid dealership/ manufacturer certificate will be entertained. If
the copies are not legible it may invite rejection.
7. Only original/ certified, legible copies of product brochure containing complete “technical
specifications” will be entertained. In case, the product brochure does not give the detailed
technical specifications, a separate sheet giving complete technical specifications and duly
signed by the bidder may be enclosed. The technical specifications must include details on
capacity, functionality of the equipment, expected working life of the equipment,
specifications of mechanical parts, optical parts, battery, battery life etc. Quote without
product brochure and the product brochure without detailed technical specifications invites
rejection.
8. The tenderer shall mention whether he has supplied identical or similar equipment to any ICAR/
CAU laboratories/institutions in the preceding three years. If yes, details of such supplies and
their price shall be mentioned along with the item quoted.
9. Only valid DGS&D registration Certificate for the items manufactured and in the approved list
may be enclosed.
10. It may be noted that rates should be quoted keeping in view the specific requirements for
installation of the equipments. The College will not provide anything except for the space, water
and electricity connections.
How to Quote?
1. The complete quote for equipment must clearly mention the following parts–
a) Unit price of the equipment (conforming to complete specifications including
accessories) as mentioned in the tender document.
b) Institutional discount offered for equipment (including accessories as demanded by the
indenter). If no discount is offered it shall be mentioned as nil.
c) Taxes/duties/levies/surcharges of Govt. of India, state government etc. (This institution is
exempted from excise duties and custom duties).
d) Packing, forwarding, freight, insurance charges for the items quoted. If no extra charges
are required it shall be mentioned as nil.
e) Other charges, if any.
f) Total prices for F.O.R Selesih. (Add all the above from “a” to “e”)
g) Prices of optional consumables or accessories or spares.
All above items from “a” to “g” shall form the complete quote.
2. The bidder shall quote equipment wise, clearly mentioning the Item serial no. and Item Code no.
mentioned in the tender document. Each quote shall be complete in all respects fulfilling
complete specifications including accessories mentioned by the indenter and all the terms and
conditions.
3. Warranty offered for the equipment.
4. Terms of Delivery.
5. Delivery schedule.
6. For all the items the bid shall be submitted item wise in separate envelops with clear
superscriptions (as required for each item) along with item serial no. and item code no. as per
tender document allput together in a single envelope with superscription as instructed in
general instruction no. 1.
7. All the bidders shall give information on availability of Annual Maintenance Contract/ After
Sales Service for F.O.R Selesih.
8. Only signed terms and conditions page need to be returned with the tender. Detailed list of
equipment and other specifications need not be sent back.
General Instructions:
1.
Tender shall be submitted in Sealed Envelope superscripted Tender No.p7/CVSC/CAU/NTP/2015 : dated 28th August, 2015 and the last date for submission
is 01.10.2015 up to1.00 p.m. The duly filled Tenders in all respects must reach :
The Dean,
College of Veterinary Sciences & A.H.
Central Agricultural University
Selesih, Aizawl-796014
Mizoram.
2.
The Tender shall be sent only by registered post or Speed Post.
3.
The Institution will not be responsible for late/ delayed delivery of Tender.
4.
The Tender shall be accompanied with following documents.
i)
Tender fee for an amount of Rs. 1000/- (Rupees One Thousand) only in the
form of Demand Draft drawn in favour of the Dean, College of Veterinary
Sciences & AH, Selesih, Aizawl payable at State bank of India, Bawngkawn
Branch (Branch Code: IFSC CODE SBIN0007059), Aizawl.
ii)
Copy of the registration Certificate of the manufacturer/authorized dealer.
ii)
Copy of manufacturing license of manufacturer/authorized dealership
Certificate.
iii)
Copy of last tax returns certificate of the tenderer.
iv)
Product technical specifications brochure in support of the items quoted.
v)
Copy of quality assurance / quality control certificates/DGS & D registration
certificate.
vi)
Terms & conditions form duly signed.
5.
Opening of Tender documents: 01.10.2015 at 3.00 p.m.
6.
Venue: Administrative Block, College of Veterinary Sciences & Animal Husbandry,
Selesih,
Aizawl, Mizoram.
Technical Specification:
Sl.
No.
01
Item
Code.
No
VAN-01
Item
Specification
High
Resolution
Microscope
imaging
Camera
with LED display
attachment
A. Camera: 14MP Digital CMOS imaging device ( Seolux
/MRC Israel) USB-2,with image analysis software
Toupview for measurement, image grabbing and
analysis along with suitable optical adapter for your
existing Olympus-BX-41Tr microscope
B. Display Attachment (Computer): Windows 8.1
operating system, Minimum Intel Core i3 processor,
Minimum 4 GB 1600 MHZ DDR3 (1X4GB) RAM, 1
TB 7200 rpm SATA hard drive, High definition Audio
5.1 DTS Sound, Integrated 10/100/1000 Gigabit
Ethernet LAN (Network), Bluetooth 4.0 Mini card
Combo, USB optical mouse, USB keyboard with
volume control, Super Multi DVD Burner, Minimum 4
USB 2.0; 4 USB 3.0; 1 head phone/microphone Combo,
Card Reader and Minimum 19.5 inch LED Monitor, 4.1
Channel stereo speaker.
Waterproof and Dustproof, Multi-Point Push-button
Calibration (up to 5/6 points) with Auto-Buffer
Recognition - choice of USA, NIST or DIN buffer
standards for quick calibration with no calibration
mistakes, User-Customization for enhanced flexibility
and viewing of electrode diagnosis - pH slope/offset/mV
base value, previous calibration points, Built-in Realtime Clock stamps stored data and calibration data with
time & date, Automatic Temperature Compensation,
Stability Indicator, Auto-Hold Function, Auto-Power
Off, Custom LCD Display, Rugged Carrying Case.
• Objectives with 10 x 40 x 100x
• Eye piece with 10x
• Improved Neubauer Counting Chamber
02
VAN-02
pH Meter
03
VPY-01
04
VPY-02
05
VPY-03
Compound
microscope
Hemocytometer
sets
Haemoglobinomete
r sets
06
07
VPY-04
VPY-05
08
VPY-06
09
VPY-07
10
VPY-08
11
VPY-09
• Haemoglobino Meter tube
• Comparator
• Stirrer
• Dripper
• Cleaning Brush
Wintrobe’s sets
• Calibration at 1mm
Kymograph
with • Digital
accessories
• Auto stop after one complete cycle
• Timer with Alarm
• Accessories or connection
Stimulators
• Frequency range from 0.1 to 100 Hz.
• Pulse Width Range from 0.1 to 5mS
• Output Amplitude up to 50 volts
• Rise and fall : > 5 µsec
• Power : 110 – 115 Volts 60 Hz or 220-230 Volts 50 Hz
Tissue chamber
• Capable of maintaining stable intracellular membrane
potential of more than 60mV
• Facilitates action potential overshoots close to 100mV in
amplitude
• Prefaration slices remain viable at least for 8hrs
• Provision for maintenance of flow rates
Sphygmomanomete • Aneroid type
r dial type
• Dial reading upto 300 m Hg
Dissecting Sets
 Should contain
 Pinning needles
 Scissors- curve and straight-small size
 Bone cutter-5Cm size
 Scalpels
 Toothed Forceps – Small size 5-6cm
12
VPY-10
13
VBC-01
14
VBC-02
15
VBC-03
16
VBC-04





Case for holding the instruments
Tweezers-small size
Spirometer
Portable
Should meet criteria of ATS standards
System software should v eased on latest Microsoft
windows operating system
 Should have accessories pneumotech screens (5 nos) ,
Mouthpieces (Disposable 250nos) Pulmonary filters (50
nos)
 Should have computer interfacing facilities, Manual and
strong carrying case, printers of the records
 Capable measuring
 Spirometry and flow volume parameters
 Maximum ventilation volume
 Lung volumes and sub divisions
 Pre and post bronchodilator comparisons
 Real time flow volume and volume traces on computer
screens
Gel rocking shaker Speed: 10-50RPM
Timer: 99 hrs 99 mins
Platform dimensions: 30 L X 30 B (cm)
Load: 10 kg
Power: AC 230V, 50Hz
Double distillation
Dist. Water output: 2.5 lit/hr
Unit, water softener Electrical requirements: 230-250 volts, single phase 4.4 kw
With stabilizer
Biological activity: Pyrogen free, Conductivity S/cm:
<1X10-6, Total organic Carbon μg/l: <500, Organic matter
mg/lit: Nil, Total solids: <0.1 mg/lit, Distillate Temp.: 6575ºC, Total plate count: 0, Standard plate count: 0, Yeast
and Mould: 0, UV absorbance at 254 nm: 0.007
Autoclave, 20 litre  Internal Volume : at least 20 liters
capacity
 Safe Pressure Range : at least up to 30 psi with pressure
gauge, safety spring loaded valve and over pressure steam
release weight controlled nozzle
 Chamber material: all Stainless Steel with SS stand and
holding vessel (1’ height)
 Heating System: ≥ 2kw with on spare heating element
 Gasket Diameter: At least 12 inches with 5 spare gaskets
 Dry run cutoff sensor inbuilt preferable
2D Electrophoresis For IEF instrument:
module Isoelectric  Dedicated instrument for immobilized pH gradient
focusing unit
isoelectric focusing
 Integrated peltier cooling platform and programmable
high voltage power supply with output range of 10,000
volts
 Immobilized pH gradient (IPG) strip chamber with a
universal or multiple focusing trays
 Run 12 or more IPG strips of 7, 11, 13, 17, 18, 24 cm
lengths simultaneously
 Re-swelling/hydration tray for accommodating 7–24 cm
length IPG strips
 Cup loading capability for improved resolution at extreme
pH ranges.
 System should include Individual Lane Control for
running different samples, pH gradients and focusing
protocols in a single run.
 System should have touch screen user interface for easily
creating and editing protocols and setting up the program
rapidly.
 System should be designed to work as stand alone or in
conjunction with PC control.
 Temperature range should be 15–30ºC ±1.0ºC
 Should be supplied with suitable online UPS
 System should be compatible for running with lightsensitive protein samples and 2D DIGE applications
 Should be provided with starter kit during installation
including set of 7, 18 cm IPG strips (pH range 4-7 and 310)
For 2D Image analysis software:
 The software should provide an user friendly interface for
the visualization, exploration and analysis of 2D gel data
and can be upgradable to DIGE
 Should provide sophisticated algorithms for automatic
spot detection, quantification, background subtraction and
noise filtering.
 Should provide spot detection summary, matching
summary, replicate group consensus tool to optimize spot
detection and matching
 Should provide 3 dimensional view of the individual
protein spots
 User adjustable significance level
 Gel land marking and automatic spot matching
 Should be able to provide histograms
 Should be included manual addition, removal and
matching of protein spots
 Sophisticated variable background removal to quantitate
low abundance protein
17
VPH&E
-01
18
VPH&E
-02
19
VPH&E
-03
Thermal
gradient
Cycler A compact table top model fitted with universal block
suitable for 0.2ml and 0.5ml PCR tubes simultaneously.
Machine should have utmost flexibility with simple
programming gradient function, adjustable ramp rates, time
and temperature increments, incubation mode, in situ mode,
link function, pause function, etc. Auto-restart mode in
case of power failure is must. With power consumption
features of 120 V and 50-60 Hz. Block temperature control
range: 4 – 99°C. Gradient range 1-200C. Lid temperature
range 37-1100 C with thermal sample protection.
Temperature distribution range across the block ± 0.60C.
Regulation accuracy per well: ±0.20C. Block temperature
accuracy 0.20C with heating rate 30C/s and cooling rate 20C/
s for cooling. Number of programmes should not be less
than 100.
Sample capacity should not be less than 96 for 0.2ml tube
and 71 for 0.5ml tube.
Minimum warranty: Two years after installation.
Horizontal
Casting tray 7 x 7cm with Spare casting tray 7 x 10cm
submarine
Electrophoresis power supply unit should run two to four
Electrophoresis unit units at constant voltage or current with maximum output of
along
with 300V, 400mA and 80watts. Time can be set in 1 minute
Electrophoresis
increment or continuous mode with all digital display.
power supply unit
Serological water
bath
Temperature range: Ambient Temperature 5°C to 80°C.
Designed for various applications in microbiology, research
and industrial laboratories.
Excellent temperature control by programmable PID
microprocessor control system.
Highly visible dual display for temperature and time.
Seamless stainless steel tank for easy cleaning.
Excellent temperature uniformity and stability by triple
insulation.
Footprint almost equal to the working area to save bench
space.
20
VPH&E
-04
pH Meter
21
VSR-01 Small
Animal
examination table
22
VSR-02
Lead
partition/
Lead barrier
23
VSR-03
Radiation
barrier
apparel (Lead apron
and lead gloves)
24
VSR-04
Autoclave Vertical,
Cap.40 ltrs.
25
VSR-05
Portable Autoclavepressure
cooker
Cap. 20ltrs,
Adjustable over temperature thermostat providing extra
safety.
Water proof and dust proof, multi point push button
calibration (up to 5 points) with auto buffer recognition for
quick calibration with no calibration mistake, user
customization for enhanced flexibility and viewing of
electrode diagnosis – PH slope/ offset/ mV base value.
Small animal examination table:
Length 28”x width 48” x height 34”
Entire table should be made up 16 gauze SS 304.
All around restraining guides (bar) with a gap of 1”
Table top inverted grooved for anti spill.
Round edges for safety.
Central column should be 12’x12” and the base pad should
be at least 6” extra than the central column to provide stable
balance.
Should not allow accumulation of blood, fluid etc.
Drainage whole on both sides with provision for hanging
Should be loaded on four anti-skid boots made of teflon
Lead partition /lead barrier
Size height 6ft x width 3ft partition on three sides
Should have 1 mm lead barrier
Should have 6”x6” window on the central screen
Casters: Four hospital grade; two locking, two non-locking.
Lead apron
 Easily slips on and off
 Comfortable to wear for long durations
 Anti-skid shoulder pads for added comfort and
weight distribution
 Uniform front and back protection with 0.5 mm
lead.
 Attachable thyroid shield
Autoclave –Vertical with SS Jacket BIS marked
Capacity: 40 litres
Chamber dimension 12” x 22”
With two drums of dimension 9” x11”
Working Pressure (15 psi – 18 psi)
Sterilizing Temperature 121°C to 140 °C
Double wall SS GMP construction
Sterilization Time 25- 30 min maximum.
Door / Lid Foot lifted with safety and interlock device
Door Locking type Wing Nut type
Should have
temperature indicator
Sterilization indicator
Low water sensor
Low water cut-off device
Sterilization indicator tape
Heat resistant handles
Portable Autoclave - Pressure Cooker
Capacity: 20 litres
Working Temperature 121°C – 140°C
Operating Pressure 15 PSI to 18 PSI
Body 304 Grade Stainless Steel
ISI marked gasket and heating element
Should have Pressure Valves
Lid Locks
Steam & vacuum release valve
Heating Electric Heating
Should have
temperature indicator
Sterilization indicator
Low water sensor
Low water cut-off device
Stainless basket with handle
Fast sterilization approx. 20 min
Heat resistant handles
26
VSR-06
Digital Weighing Digital weighing machine, Capacity 200 kg
machine,
Cap. Features: Ac Supply, Accurate, Audo Visual Over Load
200kg
Indication, Back Display Or Pole Display Inbuilt, Battery &
Stable Weight Indication On Display, Battery Save Mode
Bright LED easily readable display., Highly Sensitive. Built
in Tare facility
- Matt finish Stainless Steel Platform
- Calibration Facility
stainless steel
- Capacity : 200Kg.
- Readability/ Accuracy: 10 gm
- Material of platform : Matt finish stainless steel
- Platform size : 600X600 mm
27
VSR-07
Instrument Cabinet/ Instrument cabinet/ OR cabinet
or Cabinet
 S/S # 304 Stainless Steel
 Free Standing Operating Room Cabinet
 3/16" tempered glass Double doors with stainless
steel lockable paddle latch
 5 adjustable SS shelve
 37"L x 15."W x 69"H
 96x40x175cm
28
VSR-08
29
VSR-09
30
VSR-10
LED Shadow less Mobile LED Shadow less OT light: Shadow less, Mobile
lamp
and portable LED focusable light with arm movable and
adjustable to any angle and to focus on the operative field. It
should have three Petal type dome with at least 16 high
quality LEDs with long life (white and colour) in each to
provide at least 1,40,000 LUX illumination. Depth of
illumination should not be less than 100 cm. colour
temperature 5000K. Average LED life at least 40000 hours.
Should have movable and sterilizable handle with focusing
facilities. Should have inbuilt SMPS type 24V output power
supply and controller unit with feather touch type button for
setting the parameters with LED display unit. Intensity and
colour temp should be variable and possible to desired
illumination. Arm and mechanical parts should have
maximum maneuverability with spring balance in arm to
adjust the working distance. Sturdy base with Castor wheels
of about 3” size with lock and should move easily to any
direction. With suitable capacity branded stabilizer.
Oxygen Cylinders
Oxygen cylinder:
E tank with pin index safety
Veterinary Multi
Should be portable, Facilities for recording NIBP, SpO2,
parameter monitor
EtCO2,HR, RR.
(Portable)
NIBP: cycle time0-60min, Unit: mmHg, systolic, diastolic
and mean, high accuracy.
SpO2: range: 0-100% with high accuracy
EtCO2: range- 0-99 mmHg
31
VSR
(TVCC)
-01
Large
animal Large animal operation table (Ruminant):
Operation
Table Length 8ft x width 5ft x height 1ft
Should be able to bear at least 1000 kg weight.
(Ruminant)
VSR
(TVCC)
-02
Large
Trolley
32
Entirely made up of stainless steel S/S 16 gauze # 304 Stainless Steel
1ft adjustable at different height extension for headrest
Stainless steel sheet on the table top rounded beyond the borders
to prevent injury to the animals and accumulation of blood etc.
Should be provided with detachable and properly fitted high
grade coir mattress at least 6” thickness covered by good quality
durable turpoline.
Animal Large animal trolley
Length 6 ft x width 3 ft x height 1 ft
Should be able to bear at least 1000 kg weight.
Entirely made up of stainless steel S/S 16 gauze # 304 Stainless Steel
Mounted on four strong wheels with two movable front wheels
with a turning radius of 90 degree both side.
The wheels should be strong enough to bear the weight should
not cause friction or noise and made up of solid rubber.
There should be handle on the front side for pulling.
High grade stainless steel sheet on the table top rounded beyond
the borders to prevent injury to the animals and accumulation of
blood etc.
33
VPP-01
34
VPP-02
35
VMC-01
36
VMC-02
All Glass double All Quartz double distillation Unit with power supply setup:
distillation sets
Demountable boiler panel series, vertical model, 2.5 lit/hr
capacity, electrical requirement- 230-250 volts, single phase
4.4 kw, Minimum cooling water- 2 lit/min, distillate
quality- pyrogen free, less than 1X10-6S/cm conductivity,
less than 500 microgram total organic carbon, less than 0.1
mg/ lit total solids, 0 mg/lit organic matter, 0.007 UV
absorbance at 254nm;total plate count, standard plate count,
yeast and mould all zero.
Gel Electrophoresis Horizontal Electrophoresis midi system :
system (Horizontal) Gel dimension: 10 x 7cm & 10 x 10cm UV Tray, 2 x 16
with power pack
sample combs, loading guides and dams, Unit
dimension:12.5 x 22 x 9cm, Max. sample:10 x 7cm tray –
50 samples, Buffer volume: 300ml, Combs available(No.
of samples):1, 2, 4, 8, 10MC, 12, 16, 20MC, 25; Adhesive
Loading Guides; Viewing Platform; 10cm UV Gel Scoop;
Buffer Saver Blocks;
Horizontal Electrophoresis mini system :
Gel dimension: 7 x 7cm &7 x 10cm UV Tray, 2 x 8
Sample combs, loading guides and dams, Unit dimension:9
x 21 x 9cm, Max. sample:7 x 7cm tray – 32 samples, 7 x
10cm tray – 64 samples, Buffer volume: 225ml, Combs
available(No. of samples):1, 2, 4, 8MC, 8, 10, 12MC, 16;
Adhesive Loading Guides; Viewing Platform; 7 cm UV
Gel Scoop;
Buffer Saver Blocks;
Power supply system:
Voltage Range: - 5-600v in 1V steps
Current Range: - 5-500mA in 1mA steps
Operation Modes: - Constant Voltage, constant current
Display: - LED display
Electronic Balance
 Fully microprocessor based with full tare facilities and
LCD display and FACT calibration facility.
 Maximum capacity: 200 g.
 Readability: 0.01 mg.
 Repeatability: 0.03 mg.
 Linearity: 0.2 mg.
 Weighing pan diameter: 80-100 mm
Warranty & Pricing:
 Warranty should be at least 2 years from the date of
installation.
 Price should be quoted FOR Selesih including all the
handling and clearing charges and it is to be done by the
supplier.
BOD Incubator
 Capacity 224 Litres
 Should be double walled, in which inside should be
made of thick anodized aluminium/ stainless steel and
outside of Mild Steel Sheet furnished in Epoxy Powder
Coating.
 There should be minimum gap of 75mm between two
walls to be fitted with pure mineral wool.
 Synthetic rubber gasket should be provided on the door
for better grip.
 The incubator should have double door, in which outer
37
VMC03
Horizontal
Submarine
Electrophoresis
system,, mini-gel
38
VMC04
Laboratory Egg
Incubator: (100 to
200 eggs capacity
setter–cumHatcher)
should be metal door and inside should be glass door in
stainless steel frame.
 Heating elements should be placed in ribs at the bottom
and sides. Two adjustable air ventilators should be
placed near the top of the sides.
 The temperature should be controlled by an Electronic
Microprocessor Temperature Controller cum Indicator
from ambient to 700C with sensitivity of plus minus
0.50C.
 Should be supplied with 2 pilot lamps, air circulating
fan, perforated 4 (four) shelves (SS) adjustable at any
level, having arrangement to fit the automatic timer to
work on 220/230 volts AC only with cord and plug.
Warranty & Pricing:
 Warranty should be at least 2 years from the date of
installation.
 Price should be quoted FOR Selesih including all the
handling and clearing charges and it is to be done by the
supplier.
 Mini plus submarine gel units (10x11.5 CM gel length)
 Buffer chamber assembly
 UV transparent running tray
 Surface level detector
 Tape less gel casting facility
 Multiple combs, 8 wells, 12 wells and 16 wells
 Should be supplied with silicon gasket, high voltage
leads, colored loading strips
 Power supply: 10-300V, 4-500mA, 90W with the
options for minimum two simultaneous gel run.
Warranty & Pricing:
 Warranty should be at least 2 years from the date of
installation.
 Price should be quoted FOR Selesih including all the
handling and clearing charges and it is to be done by the
supplier.
Setter trays:- Chicken eggs: >100; Goose eggs: >50; Duck
eggs: >75, Bird(pigeon) eggs : >200.
Hatcher tray: suitable for hatching the eggs specified for
the setter tray(s).
Egg candler: Suitable for candling the different eggs in
place in the setter trays at different time of egg incubation
without removing from the trays as a standard accessory
Voltage: 220V /230V±2% stabilized by automatic
electronic main line (120V to 280V) single phase voltage
stabilizer > 5KVA with high and low voltage cutoff
Hatching rate: Above 96% based on fertility determination
by candling on 10th day of incubation
Functions: Full-automatic electronic/ microprocessor
controlled egg Incubator for setting and hatching Chicken,
Bird (pigeon), Duck, Turkey, Quail, Goose eggs with
preferably energy-saving and environment protection
certification.
Technical Parameters:
Range of temperature adjustment: 5~50°C with0 .01°C
increment
Precision temperature control: ±0.05°C. Range of
humidity display: 0~99%RH
Turns of egg turning: Max turnings recordable up to 999
times
Time interval of egg turning: Adjustable between 0.1 to
99.9 hours
Time interval of ventilation: Adjustable between 5 and
999 minutes
Ventilation Time: Adjustable between 0 and 999 second.
Quality Assurance: CE certification
Power back up: 3 KVA(power factor ≥0.8 with generator
compatibility) on-line UPS capable of handling at 60% load
110-300 Volt input voltage with surge protection and ≥8
numbers 42AH SMF batteries not older than 4months at the
time of supply (Emerson/APC/Fuji)
Warranty: 24months comprehensive warranty from the
date of installation.
39
LPT-01
Laminar Flow
40
LPT-02
41
LPT-03
Defeathering
Machine
Salting Instruments
(Brine Injector)
42
VOG-01
43
VOG-02
44
VOG-03
45
VOG-04
46
VPA-01
47
VPA-02
Vertical, 0.3 microns HEPA Filters, 99.97% filtration efficiency
Work table covered with Stainless Steel, Fitted with Static
pressure Indicator (Manometer). Air velocity between 0.4 to 0.5
mls + - 20%
Stabilisation through UV - Germiciadal Tubes Size 25(2"x2" or
irxtrx4"
Specification: 15 birds at a time, stainless steel (food grade),
Motor capacity – 1 HP; Rubber pluckers of export quality.
Stainless steel cover, high power resources, integrated
pressure control with manometer, suck-in-device with pre
filter device, integrated feed back system, easy and
thorough cleaning, low power consumption, quick change
of injection needles, glycerin-filled manometer 0-6 bar,
injection needles from stainless steel 200x4mm, injection
pistol from metal, chromium plated,
Motor output: 0.5 KW/CA .5BAR
Voltage: 400V, 50Hz, 3PH
Dimensions: 390x180x240 MM
With metal injection pistol, single as well as multiple needle
– 200 x 4 mm, 2 needle pork S.S. 150 X 4 MM; 3 needle
pork S.S. 150 X 4 MM;
Stereo
zoom Stereo zoom Microscope:
Optical Trinocular Body,
Microscope
zoom ration 1:7, objective zoom range 0.65X-4.5X with
high point super wide field eyepiece, minimum working
distance 100 mm with a detached high resolution camera
and display, head inclination 450with top halogen lamp and
auxiliary lenses of 1.5X and 2.0 X
Electric Sterilizer:
Electric Sterilizer: Export Quality Stainless Steel fitted
with Immersion Heater 24x12x12”
Triple
Glass Dist. Water output: 2.5 lit/hr
Distillation set.
Electrical requirements: 230-250 volts, single phase 4.4 kw
Biological activity: Pyrogen free, Conductivity S/cm:
<1X10-6, Total organic Carbon μg/l: <500, Organic matter
mg/lit: Nil, Total solids: <0.1 mg/lit, Distillate Temp.: 6575ºC, Total plate count: 0, Standard plate count: 0, Yeast
and Mould: 0, UV absorbance at 254 nm: 0.007
pH Meter
Benchtop meter with DIN socket with electrode. AC or
battery operation. Meter with universal power supply
Buffer 4, 7 and 10, 01, 3 mol/1 KCL
Horizontal
Electrophoresis unit with casting tray 7 x 7 cm with Spare
Electrophoresis
casting tray 7 x 10 cm
system with power Electrophoresis power supply unit. It should run two to
pack
four units at constant voltage or constant current with
maximum output of 10–500 V, fully adjustable in 1 V
steps,400mA and 80 Watts. Time can be set in 1 minute
increment or continuous mode with all digital display.
Should have safety features like no-load detection, sudden
load change detection, ground leak detection, overload/short
circuit protection, overvoltage detection, input line
protection, auto power-up after power failure, Operating
conditions like 0–40°C, 0–90% humidity in the absence of
condensation, etc.
Stereozoom
Optical System should have Greenough optical system,
Microscope
Total Magnification ranging from 3.35-600x, Eyepiece
inclination should be minimum 450 , Eyepieces C-W 10xB
(F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W
48
VPA-03
49
VPA-04
50
ANN-01
51
ANN-02
52
ANN-03
30x with diopter adjustment, Zoom Range 0.67-11x, Zoom
Ratio 7.5:1, Working Distance should be more than 110mm,
this system should be equipped with a camera port with Cmount adapter with digital camera and monitor system
enabling image capture. Operating Environment should
withstand high humidity. Proper power backup system
should be supplied along with the machine.
Compound
Optical system should be UIS with 6V 30W halogen bulb,
Microscope
voltage should be 220-240V, Nose piece should have
(Trinocular)
universal revolving type, observation tube with super wide
field with 3 position trinocular type, inclination upto 45o,
specimen holder should have the provision for 2 slide,
condenser should be planachromat, objective range should
be with 4x, 10x, 40x and 100x, should be antifungus treated,
should withstand upto 90% humidity environment, it should
be supplied with detachable digital consumer camera with
monitor display system, should be supplied with extra bulb,
shoild have co-observation facilities and power back-up
system
Double Distillation Automatic Cabinet Double Distillation Unit. High quality,
unit
Low Temperature Output all distil-on Distillation Plant
should manufactured by using GE 214 Semiconductor
grade Quartz for the Doubler Coil Condensor and boiler
system, combined with a silica glass sheathed heating
element . Should provides a high quality pirogen free output
with conductivity < 0.4 µS/cm. The system should be
designed for fully automatic operation.
Further Features should be present like:
Flow Control Safety ,
A Gate ,
Level ,
Reservoir Level Sensor ,
Output Water Capacity should be more than 2 ltr/hour.
Power – 230 volt, 50 / 60 Hz, Single phase 3.4 kw.
Equipment should be supplied with at least 2 Nos.
20
Ltr. Capacity Water Reservoir with Tap .
Bomb Calorimeter
Microprocessor based-operated through software & PC and
should be supplied with PC and its accessories, Automatic
feeding of Calorific values of ignition wire & cotton thread,
Automatic firing in the Bomb Automatic Detection of
maximum rise of Temperature, Automatic calculation of
Water equivalent/ calorific values in each experiment,
Automatic delivery of result data in report format,
Automatic graph plotting between time vs, temperature.
Battery backup for stirrer and Microprocessor unit
(UOS),8interface to connect with computer, soft touch Key
pad, auto firing , Detection of maximum rise of
Temperature, LCD display with backlit 16 x 2 characters,
compatible with USB/ serial port of PC.
Hot Air Oven
Double-walled inside made of thick anodized Stainless
Steel and outside of Mild Steel furnished in Epoxy Powder
Coating , gap between two walls is filled with pure mineral
wool, provided with Synthetic rubber gasket on the door for
better grip, Heating elements are placed in ribs at the
bottom and sides, Adjustable air ventilators near the top of
the sides, temperature controlled by and Electronic Digital
controller cum indicator form room /few ºC above ambient
to 250ºC with sensitivity of plus minus 0.5 deg. C, supplied
complete with two pilot lamps, p[perforated shelves
adjustable at any level having arrangement to fit the
automatic time to works on 220/230 volts A.C. cord and
plug . Completer with air circulating fan Size:
605X605X910mm (336Ltrs.)
Muffle furnace
Microprocessor PID controller having 4 ramp & soak
profile having set mode, made of thick mild sheet having
53
ANN-04
54
AGB-01
55
AGB-02
powder coated in good looking colour, Ceramic Fibre
blanket for high density for better insulation, provide with
Stainless-steel 310 Qlty. Base plate to safe guard the interior
chamber Heating Elements are made of special Kanthal
wire to make furnace working continuously up to 1150ºC,
fitted with fine quality Digital indicator cum controller to
work on 220Volt AC 50Hz, size: 300 X 300 X 605 mm.
Automatic Kjeldah Microprocessor based, PC compatible, Auto mode
Nitrogen
programmable-5-35ml manual mode continuous, alkali tank
Distillation system capacity-2 Litres, peristaltic pump with spring loaded rotor
and anti-corrosive pump head for alkali addition.
Distillation time programmable, distillation capacity-12-25
sample/hr,steam generator stainless steel with water level
View window, auto electronicsmicroswitch controller for
water level. Automatic replacement of steam by a balancer
devise, steam capacity constant by thermostatic preheating
mechanism, auto readysignal for steam processing nitrogen
recovery -99.5-100%, Electrical requirement: 220v/50Hz,
Automatic sample dilution, automatic and manual alkali
addition digital real time count down, Automatic KMno4for
available nitrogen facility, automatic error diagnostic
features.
pH Meter
1. Should have Working range from 0 to 14.
2. Should have resolution 0.1/0.01 pH.
3. Should have Temperature compensation zero to 100
degree C with ATC
4. Should have RS.232C output and supply Data connector
cable.
5. Should have Automatic calibration facility.
6. Should have data storage facility and record maximum
and minimum value.
7. Should have 3 stage calibration.
8. Should have digital display with 0.001 pH unit
readability
9. Should supply Tri-combination pH/ATC electrode
10. Should supply Electrode + Standard buffer solution (pH
4.0, 7.0, 10.01 x 50ml for each bottle) + standard electrode
holder +Ac /DC Adaptor.
11. Should be provided with an electrode holder/arm with
smooth movement.
Autoclave
1. Should have a triple walled construction.
2. The working chamber, steam jacket, outer chamber and
the lid should be made of stainless steel.
3. Should have water inlet and outlet valves.
4. Should have a water level gauge
5. Should have gauges for measuring inner and outer
steam pressure.
6. Should have an inner temperature indicator.
7. Should have automatic pressure control switch, safety
valve and eject valve.
8. Should have joint-less silicone gasket.
9. Should have automatic low water protection.
10. Should be supplied along with bins.
11. Should have an ISI mark.
12. Should have 121ºC working temperature at 15 to 20 psi
pressure.
13. Chamber volume should be approximately 300mm
diameter and 500mm depth with minimum 2 bin type.
14. Should be operated in mains 220 – 240 V ac 50 Hz
input power supply.
15. Water inlet and outlet pipe should be provided and
connections should be done on a turnkey basis.
56
VHE-01
57
VHE-02
58
LPM-01
LPM-02
59
60
LPM-03
61
LPM-04
62
LPM-05
63
LPM-06
64
LPM-07
65
LPM-08
66
LPM-09
67
LPM-10
68
LPM-11
69
LPM-12
LCD Data Projector LCD Data Projector
Resolution: 1280X800 pixel, Brightness: 3200 ANSI,
Contrast: 2500:1, Connectivity:HDMI, S-Video, USB,
Aspect Ratio: 4:3
INFORMATION
INFORMATION KIOSK
KIOSK
Display
Display
(a) Type : Colour LCD
(b) Size : 48.3 cm (19 inches)
(c) Resolution : 1280 x 1024
(d) LCD Touch Panel : Minimum 250 CD/m2 (NITS)
brightness
System Details
(a) Processor :Embedded processor, 2.0 GHz or higher 3
MB Cacheor higher.
(b) Memory : 2 GB or higher
(c) HDD/Storage :250 GB or higher
(d) Audio : 1 x Line-out/1 Line-in
(e) Speaker : 2x1.5 Watt, RMS Stereo speaker.
(f) Operating System : Windows 8 Professional with USB
based keyboard
Debreaker
with Electrically operated, brass blade, cuts beak and cauetieses
stand
in a single operation
AI Equipment set AI Equipment set for-pig, cow and goat
for
different
species
Milk
Packing For Milk, Water, lassi, Juice, Virgin multilayer co-extruded
Machine
L.D.P.E film, Fill quantity: 200 ml to 1000ml, Gravity
filling electromagnetic system, 2500 Pouches per hour,
Impulse sealing, Standard vertical overlap, accuracy: +-2%
up to 500ml, electric supply single phase, 50 Hz, 230 V+1% and neutral connection to connected load 4 KW
Automatic scalder
18”DIA. With temp guage & gas fittings and stainless steel
cover. 1HP motor
De-feathering
Without door, gear box model 0.5 hp, 1 Phase approx..
Machine
Load Capacity- 7.5 kg.
Digital Weighing Accuracy-10mg.(approx.), electric and battery operated,
Balance (300kg)
platform type (minimum 10cm diameter)
Digital Weighing Accuracy-5g(approx.), electric and battery operated,
Balance (30kg)
platform type (size-30cmx20cm minimum)
Weighing Balance Spring/mechanical, Pan type: pan size-15cm x 15cm
(Spring)
(minimum), dial type, made of metal (for 10&20kg)
2kg,5kg,10kg,20kg
Water Distillation Single distillation unit made of glass, distilled water outputapparatus
4lit/hr, electrical requirement:230-250 volts, single phase
3.5kw, quartz heater, cool water consumption-not more than
70 lit/hr, distilled water pH 6-7, pyrogen free.
Milking Machine Vacuum and Massage technique with help of Aero Pulsator
(Bucket
Type) with pulse rate of 60ppm & Pulsation Ratio 65:35 and
Double
special cluster MC11. Trolley type.
Back Fat scanner Range/Accuracy:4-35mm (0.156”-1.365”) +/-1 digit
for pig
Display
# 2-digit LED for thickness
3 LED’s to indicate 1,2 or3 layers being measured
Baterry charging LED
Controls: On/Off push button
Power supply: Nickel Metal Hydride battery
Battery Pack Life: approximately 2-4 years (1000
charges/discharges)
Milk Analyser
For measurements of fat and SNT in raw cow and buffalo
milk
Ability to screen for non-pure milk,
Detection of specific adulterants
Easy to use, self-contained instrument
70
LPM-14
71
LPM-15
Measurement results can be transferred directly to PC via
RS232, eliminates human sources or readings, Replaces
manual and time consuming Gerber and Lactometer
methods, Logging of all operations available.
Accessories
 Adaptor,
 4 GB Memory Card.
 Clean solution
 Descalding Solution
 Clean Bottle-1ltr.
 Zero Bottle-1ltr.
 Descalding Bottle-15oml.
 RS-232 Cabfle
 Manual Clean Kit
 PM Kit
 Quick Guide
 Instrument Bag
 Napkin
 Measuring Cups
 Descaling Cup
Identification tags Tags numbered on both sides, made of nylon flex.
for goats, pigs and
cattle
Quail egg setting Capacity – 90 eggs, made of good quality plastic.
tray