OFFICE OF THE DEAN COLLEGE OF VETERINARY SCIENCES & ANIMAL HUSBANDRY CENTRAL AGRICULTURAL UNIVERSITY SELESIH,AIZAWL,MIZORAM. QUOTATION FOR SCIENTIFIC EQUIPMENTS Selesih, the 28th August, 2015 No.P-7/CVSC/CAU/NTP/2015/ /: Sealed quotations are invited for supply of the following scientific equipments for different Departments and veterinary hospital, College of Veterinary Sciences & Animal Husbandry, Central Agricultural University, Selesih, Aizawl, Mizoram. The last date of submission of quotation is 01.10.2015 at 1.00 pm and the quotations will be opened on 01.10.2015 at 3:00pm in the Conference Hall by the college purchase committee. (D. Kathiresan) Dean CENTRAL AGRICULTURAL UNIVERSITY College of Veterinary Sciences & Animal Husbandry Selesih, Aizawl: Mizoram TERMS AND CONDITIONS FOR PURCHASE OF EQUIPMENT 1. Rates quoted shall clearly mention taxes/levies, packing, forwarding, freight, transit insurance, octroi, delivery charges, installation and demonstration at College of Veterinary Sciences & Animal Husbandry, Selesih as per quoting instructions. This Institution is exempted from Excise & Custom duties; hence, should not be included. If necessary it may be mentioned separately. The DSIR, Govt. of India Registration Certificate for Excise & Custom duties exemption along with requisite documents will be provided at the time of purchase. 2. All the equipment shall be delivered in India for payment in Rupees in India. Only equipment of reputed brands and duly registered (Registration certificate to be enclosed) shall be quoted. Quotations for unregistered brands/assembled equipments will be summarily rejected. 3. 2 % Earnest Money deposit (EMD) forms an integral part of the tender without which the tender will be invalid. The EMD will be returned to unsuccessful bidders after the purchase decision is taken. 4. Copy of ISO/Quality Assurance Certificate, quality control certificate, authorized dealership certificate/Registration certificate with DGS&D and as applicable from the manufacturer has to be furnished. Detailed specifications for the quoted equipments should be given in the quotation and should be supported by product brochure of the manufacturer. 5. Delivery, installation and demonstration of equipments has to be made at the Institution, which is 12 Km. short of Aizawl, located on Aizawl-Sihphir-Silchar Road. No responsibility will be taken to receive consignments from any other agency. 6. Consignee: Dean, College of Veterinary Sciences & A.H.(CAU), Selesih, Aizawl – 796 014, Mizoram. 7. Rates quoted should be valid for at least one year from the last date for receipt of the quotations. The quotations should be accompanied with manufacturer’s consumer price list in effect for the said period & in no case should exceed the listed price. However, if there is decrease in the manufacturer’s price on the date of supply (billing date) the same has to be passed on to the Institution if the brand is selected for purchase based on open tender. 8. Supply must be completed within 45 days from the date of issue of supply order unless otherwise specified; failing which the order may be cancelled. 9. No advance payment will be made prior to delivery and installation of the equipments/appliances to the full satisfaction of the indenter. 10. The equipment/appliances should be meeting the specifications in the tender document and any deviation in that matter may result in rejection. 11. At least one-year warranty should be provided from the date of delivery and installation and free service should be provided at the Institution during this period, if necessary. 12. Supply will be made at supplier’s risk and any damage/breakage before the installation/delivery has to be replaced by the supplier without any extra cost. 13. In case of poor quality and unsatisfactory operation of equipment/appliances the Institution reserves the right to reject them at the time of delivery and installation. 14. The dealer/manufacturer has to provide manufacturer’s quality control/test certificate of each equipment/appliances without fail at the time of supply. 15. After successful execution of a supply order payment will be made within 30 days. 16. The Institution authorities reserve the right to accept/reject any or all of the tenders received without assigning any reason there of. In case of any dispute, the decision of the University authorities shall be final and binding. DECLARATION I have gone through the above terms and conditions and agree to abide by them in the event of receipt of a supply order from the Institution based on tender. I understand that in the event of tender being quoted is not as per the quoting instructions; it may invite rejection of the tender. Date : Place: Signature of the Bidder QUOTING INSTRUCTIONS. 1. No clear mentioning of packing, forwarding, freight and insurance charges in the tender will be considered as incomplete; and will be rejected. 2. Optional accessories offered by the bidder would not be taken into consideration for the evaluation of bid. 3. Alternate offer is not permitted. In case of quoting of more than one offer, only the lowest one will be consider as valid one and the others will not be considered for evaluation of bid. 4. Quote must include all accessories asked for by the indenter. If the accessories are not detailed in the product brochure it must be clearly mentioned in the tender along with their price. Otherwise it invites rejection on the ground of incomplete quote. 5. Expected working life of the equipment is an important specification and may clearly be mentioned in the quote for all items. 6. Only certified, legible copies of valid dealership/ manufacturer certificate will be entertained. If the copies are not legible it may invite rejection. 7. Only original/ certified, legible copies of product brochure containing complete “technical specifications” will be entertained. In case, the product brochure does not give the detailed technical specifications, a separate sheet giving complete technical specifications and duly signed by the bidder may be enclosed. The technical specifications must include details on capacity, functionality of the equipment, expected working life of the equipment, specifications of mechanical parts, optical parts, battery, battery life etc. Quote without product brochure and the product brochure without detailed technical specifications invites rejection. 8. The tenderer shall mention whether he has supplied identical or similar equipment to any ICAR/ CAU laboratories/institutions in the preceding three years. If yes, details of such supplies and their price shall be mentioned along with the item quoted. 9. Only valid DGS&D registration Certificate for the items manufactured and in the approved list may be enclosed. 10. It may be noted that rates should be quoted keeping in view the specific requirements for installation of the equipments. The College will not provide anything except for the space, water and electricity connections. How to Quote? 1. The complete quote for equipment must clearly mention the following parts– a) Unit price of the equipment (conforming to complete specifications including accessories) as mentioned in the tender document. b) Institutional discount offered for equipment (including accessories as demanded by the indenter). If no discount is offered it shall be mentioned as nil. c) Taxes/duties/levies/surcharges of Govt. of India, state government etc. (This institution is exempted from excise duties and custom duties). d) Packing, forwarding, freight, insurance charges for the items quoted. If no extra charges are required it shall be mentioned as nil. e) Other charges, if any. f) Total prices for F.O.R Selesih. (Add all the above from “a” to “e”) g) Prices of optional consumables or accessories or spares. All above items from “a” to “g” shall form the complete quote. 2. The bidder shall quote equipment wise, clearly mentioning the Item serial no. and Item Code no. mentioned in the tender document. Each quote shall be complete in all respects fulfilling complete specifications including accessories mentioned by the indenter and all the terms and conditions. 3. Warranty offered for the equipment. 4. Terms of Delivery. 5. Delivery schedule. 6. For all the items the bid shall be submitted item wise in separate envelops with clear superscriptions (as required for each item) along with item serial no. and item code no. as per tender document allput together in a single envelope with superscription as instructed in general instruction no. 1. 7. All the bidders shall give information on availability of Annual Maintenance Contract/ After Sales Service for F.O.R Selesih. 8. Only signed terms and conditions page need to be returned with the tender. Detailed list of equipment and other specifications need not be sent back. General Instructions: 1. Tender shall be submitted in Sealed Envelope superscripted Tender No.p7/CVSC/CAU/NTP/2015 : dated 28th August, 2015 and the last date for submission is 01.10.2015 up to1.00 p.m. The duly filled Tenders in all respects must reach : The Dean, College of Veterinary Sciences & A.H. Central Agricultural University Selesih, Aizawl-796014 Mizoram. 2. The Tender shall be sent only by registered post or Speed Post. 3. The Institution will not be responsible for late/ delayed delivery of Tender. 4. The Tender shall be accompanied with following documents. i) Tender fee for an amount of Rs. 1000/- (Rupees One Thousand) only in the form of Demand Draft drawn in favour of the Dean, College of Veterinary Sciences & AH, Selesih, Aizawl payable at State bank of India, Bawngkawn Branch (Branch Code: IFSC CODE SBIN0007059), Aizawl. ii) Copy of the registration Certificate of the manufacturer/authorized dealer. ii) Copy of manufacturing license of manufacturer/authorized dealership Certificate. iii) Copy of last tax returns certificate of the tenderer. iv) Product technical specifications brochure in support of the items quoted. v) Copy of quality assurance / quality control certificates/DGS & D registration certificate. vi) Terms & conditions form duly signed. 5. Opening of Tender documents: 01.10.2015 at 3.00 p.m. 6. Venue: Administrative Block, College of Veterinary Sciences & Animal Husbandry, Selesih, Aizawl, Mizoram. Technical Specification: Sl. No. 01 Item Code. No VAN-01 Item Specification High Resolution Microscope imaging Camera with LED display attachment A. Camera: 14MP Digital CMOS imaging device ( Seolux /MRC Israel) USB-2,with image analysis software Toupview for measurement, image grabbing and analysis along with suitable optical adapter for your existing Olympus-BX-41Tr microscope B. Display Attachment (Computer): Windows 8.1 operating system, Minimum Intel Core i3 processor, Minimum 4 GB 1600 MHZ DDR3 (1X4GB) RAM, 1 TB 7200 rpm SATA hard drive, High definition Audio 5.1 DTS Sound, Integrated 10/100/1000 Gigabit Ethernet LAN (Network), Bluetooth 4.0 Mini card Combo, USB optical mouse, USB keyboard with volume control, Super Multi DVD Burner, Minimum 4 USB 2.0; 4 USB 3.0; 1 head phone/microphone Combo, Card Reader and Minimum 19.5 inch LED Monitor, 4.1 Channel stereo speaker. Waterproof and Dustproof, Multi-Point Push-button Calibration (up to 5/6 points) with Auto-Buffer Recognition - choice of USA, NIST or DIN buffer standards for quick calibration with no calibration mistakes, User-Customization for enhanced flexibility and viewing of electrode diagnosis - pH slope/offset/mV base value, previous calibration points, Built-in Realtime Clock stamps stored data and calibration data with time & date, Automatic Temperature Compensation, Stability Indicator, Auto-Hold Function, Auto-Power Off, Custom LCD Display, Rugged Carrying Case. • Objectives with 10 x 40 x 100x • Eye piece with 10x • Improved Neubauer Counting Chamber 02 VAN-02 pH Meter 03 VPY-01 04 VPY-02 05 VPY-03 Compound microscope Hemocytometer sets Haemoglobinomete r sets 06 07 VPY-04 VPY-05 08 VPY-06 09 VPY-07 10 VPY-08 11 VPY-09 • Haemoglobino Meter tube • Comparator • Stirrer • Dripper • Cleaning Brush Wintrobe’s sets • Calibration at 1mm Kymograph with • Digital accessories • Auto stop after one complete cycle • Timer with Alarm • Accessories or connection Stimulators • Frequency range from 0.1 to 100 Hz. • Pulse Width Range from 0.1 to 5mS • Output Amplitude up to 50 volts • Rise and fall : > 5 µsec • Power : 110 – 115 Volts 60 Hz or 220-230 Volts 50 Hz Tissue chamber • Capable of maintaining stable intracellular membrane potential of more than 60mV • Facilitates action potential overshoots close to 100mV in amplitude • Prefaration slices remain viable at least for 8hrs • Provision for maintenance of flow rates Sphygmomanomete • Aneroid type r dial type • Dial reading upto 300 m Hg Dissecting Sets Should contain Pinning needles Scissors- curve and straight-small size Bone cutter-5Cm size Scalpels Toothed Forceps – Small size 5-6cm 12 VPY-10 13 VBC-01 14 VBC-02 15 VBC-03 16 VBC-04 Case for holding the instruments Tweezers-small size Spirometer Portable Should meet criteria of ATS standards System software should v eased on latest Microsoft windows operating system Should have accessories pneumotech screens (5 nos) , Mouthpieces (Disposable 250nos) Pulmonary filters (50 nos) Should have computer interfacing facilities, Manual and strong carrying case, printers of the records Capable measuring Spirometry and flow volume parameters Maximum ventilation volume Lung volumes and sub divisions Pre and post bronchodilator comparisons Real time flow volume and volume traces on computer screens Gel rocking shaker Speed: 10-50RPM Timer: 99 hrs 99 mins Platform dimensions: 30 L X 30 B (cm) Load: 10 kg Power: AC 230V, 50Hz Double distillation Dist. Water output: 2.5 lit/hr Unit, water softener Electrical requirements: 230-250 volts, single phase 4.4 kw With stabilizer Biological activity: Pyrogen free, Conductivity S/cm: <1X10-6, Total organic Carbon μg/l: <500, Organic matter mg/lit: Nil, Total solids: <0.1 mg/lit, Distillate Temp.: 6575ºC, Total plate count: 0, Standard plate count: 0, Yeast and Mould: 0, UV absorbance at 254 nm: 0.007 Autoclave, 20 litre Internal Volume : at least 20 liters capacity Safe Pressure Range : at least up to 30 psi with pressure gauge, safety spring loaded valve and over pressure steam release weight controlled nozzle Chamber material: all Stainless Steel with SS stand and holding vessel (1’ height) Heating System: ≥ 2kw with on spare heating element Gasket Diameter: At least 12 inches with 5 spare gaskets Dry run cutoff sensor inbuilt preferable 2D Electrophoresis For IEF instrument: module Isoelectric Dedicated instrument for immobilized pH gradient focusing unit isoelectric focusing Integrated peltier cooling platform and programmable high voltage power supply with output range of 10,000 volts Immobilized pH gradient (IPG) strip chamber with a universal or multiple focusing trays Run 12 or more IPG strips of 7, 11, 13, 17, 18, 24 cm lengths simultaneously Re-swelling/hydration tray for accommodating 7–24 cm length IPG strips Cup loading capability for improved resolution at extreme pH ranges. System should include Individual Lane Control for running different samples, pH gradients and focusing protocols in a single run. System should have touch screen user interface for easily creating and editing protocols and setting up the program rapidly. System should be designed to work as stand alone or in conjunction with PC control. Temperature range should be 15–30ºC ±1.0ºC Should be supplied with suitable online UPS System should be compatible for running with lightsensitive protein samples and 2D DIGE applications Should be provided with starter kit during installation including set of 7, 18 cm IPG strips (pH range 4-7 and 310) For 2D Image analysis software: The software should provide an user friendly interface for the visualization, exploration and analysis of 2D gel data and can be upgradable to DIGE Should provide sophisticated algorithms for automatic spot detection, quantification, background subtraction and noise filtering. Should provide spot detection summary, matching summary, replicate group consensus tool to optimize spot detection and matching Should provide 3 dimensional view of the individual protein spots User adjustable significance level Gel land marking and automatic spot matching Should be able to provide histograms Should be included manual addition, removal and matching of protein spots Sophisticated variable background removal to quantitate low abundance protein 17 VPH&E -01 18 VPH&E -02 19 VPH&E -03 Thermal gradient Cycler A compact table top model fitted with universal block suitable for 0.2ml and 0.5ml PCR tubes simultaneously. Machine should have utmost flexibility with simple programming gradient function, adjustable ramp rates, time and temperature increments, incubation mode, in situ mode, link function, pause function, etc. Auto-restart mode in case of power failure is must. With power consumption features of 120 V and 50-60 Hz. Block temperature control range: 4 – 99°C. Gradient range 1-200C. Lid temperature range 37-1100 C with thermal sample protection. Temperature distribution range across the block ± 0.60C. Regulation accuracy per well: ±0.20C. Block temperature accuracy 0.20C with heating rate 30C/s and cooling rate 20C/ s for cooling. Number of programmes should not be less than 100. Sample capacity should not be less than 96 for 0.2ml tube and 71 for 0.5ml tube. Minimum warranty: Two years after installation. Horizontal Casting tray 7 x 7cm with Spare casting tray 7 x 10cm submarine Electrophoresis power supply unit should run two to four Electrophoresis unit units at constant voltage or current with maximum output of along with 300V, 400mA and 80watts. Time can be set in 1 minute Electrophoresis increment or continuous mode with all digital display. power supply unit Serological water bath Temperature range: Ambient Temperature 5°C to 80°C. Designed for various applications in microbiology, research and industrial laboratories. Excellent temperature control by programmable PID microprocessor control system. Highly visible dual display for temperature and time. Seamless stainless steel tank for easy cleaning. Excellent temperature uniformity and stability by triple insulation. Footprint almost equal to the working area to save bench space. 20 VPH&E -04 pH Meter 21 VSR-01 Small Animal examination table 22 VSR-02 Lead partition/ Lead barrier 23 VSR-03 Radiation barrier apparel (Lead apron and lead gloves) 24 VSR-04 Autoclave Vertical, Cap.40 ltrs. 25 VSR-05 Portable Autoclavepressure cooker Cap. 20ltrs, Adjustable over temperature thermostat providing extra safety. Water proof and dust proof, multi point push button calibration (up to 5 points) with auto buffer recognition for quick calibration with no calibration mistake, user customization for enhanced flexibility and viewing of electrode diagnosis – PH slope/ offset/ mV base value. Small animal examination table: Length 28”x width 48” x height 34” Entire table should be made up 16 gauze SS 304. All around restraining guides (bar) with a gap of 1” Table top inverted grooved for anti spill. Round edges for safety. Central column should be 12’x12” and the base pad should be at least 6” extra than the central column to provide stable balance. Should not allow accumulation of blood, fluid etc. Drainage whole on both sides with provision for hanging Should be loaded on four anti-skid boots made of teflon Lead partition /lead barrier Size height 6ft x width 3ft partition on three sides Should have 1 mm lead barrier Should have 6”x6” window on the central screen Casters: Four hospital grade; two locking, two non-locking. Lead apron Easily slips on and off Comfortable to wear for long durations Anti-skid shoulder pads for added comfort and weight distribution Uniform front and back protection with 0.5 mm lead. Attachable thyroid shield Autoclave –Vertical with SS Jacket BIS marked Capacity: 40 litres Chamber dimension 12” x 22” With two drums of dimension 9” x11” Working Pressure (15 psi – 18 psi) Sterilizing Temperature 121°C to 140 °C Double wall SS GMP construction Sterilization Time 25- 30 min maximum. Door / Lid Foot lifted with safety and interlock device Door Locking type Wing Nut type Should have temperature indicator Sterilization indicator Low water sensor Low water cut-off device Sterilization indicator tape Heat resistant handles Portable Autoclave - Pressure Cooker Capacity: 20 litres Working Temperature 121°C – 140°C Operating Pressure 15 PSI to 18 PSI Body 304 Grade Stainless Steel ISI marked gasket and heating element Should have Pressure Valves Lid Locks Steam & vacuum release valve Heating Electric Heating Should have temperature indicator Sterilization indicator Low water sensor Low water cut-off device Stainless basket with handle Fast sterilization approx. 20 min Heat resistant handles 26 VSR-06 Digital Weighing Digital weighing machine, Capacity 200 kg machine, Cap. Features: Ac Supply, Accurate, Audo Visual Over Load 200kg Indication, Back Display Or Pole Display Inbuilt, Battery & Stable Weight Indication On Display, Battery Save Mode Bright LED easily readable display., Highly Sensitive. Built in Tare facility - Matt finish Stainless Steel Platform - Calibration Facility stainless steel - Capacity : 200Kg. - Readability/ Accuracy: 10 gm - Material of platform : Matt finish stainless steel - Platform size : 600X600 mm 27 VSR-07 Instrument Cabinet/ Instrument cabinet/ OR cabinet or Cabinet S/S # 304 Stainless Steel Free Standing Operating Room Cabinet 3/16" tempered glass Double doors with stainless steel lockable paddle latch 5 adjustable SS shelve 37"L x 15."W x 69"H 96x40x175cm 28 VSR-08 29 VSR-09 30 VSR-10 LED Shadow less Mobile LED Shadow less OT light: Shadow less, Mobile lamp and portable LED focusable light with arm movable and adjustable to any angle and to focus on the operative field. It should have three Petal type dome with at least 16 high quality LEDs with long life (white and colour) in each to provide at least 1,40,000 LUX illumination. Depth of illumination should not be less than 100 cm. colour temperature 5000K. Average LED life at least 40000 hours. Should have movable and sterilizable handle with focusing facilities. Should have inbuilt SMPS type 24V output power supply and controller unit with feather touch type button for setting the parameters with LED display unit. Intensity and colour temp should be variable and possible to desired illumination. Arm and mechanical parts should have maximum maneuverability with spring balance in arm to adjust the working distance. Sturdy base with Castor wheels of about 3” size with lock and should move easily to any direction. With suitable capacity branded stabilizer. Oxygen Cylinders Oxygen cylinder: E tank with pin index safety Veterinary Multi Should be portable, Facilities for recording NIBP, SpO2, parameter monitor EtCO2,HR, RR. (Portable) NIBP: cycle time0-60min, Unit: mmHg, systolic, diastolic and mean, high accuracy. SpO2: range: 0-100% with high accuracy EtCO2: range- 0-99 mmHg 31 VSR (TVCC) -01 Large animal Large animal operation table (Ruminant): Operation Table Length 8ft x width 5ft x height 1ft Should be able to bear at least 1000 kg weight. (Ruminant) VSR (TVCC) -02 Large Trolley 32 Entirely made up of stainless steel S/S 16 gauze # 304 Stainless Steel 1ft adjustable at different height extension for headrest Stainless steel sheet on the table top rounded beyond the borders to prevent injury to the animals and accumulation of blood etc. Should be provided with detachable and properly fitted high grade coir mattress at least 6” thickness covered by good quality durable turpoline. Animal Large animal trolley Length 6 ft x width 3 ft x height 1 ft Should be able to bear at least 1000 kg weight. Entirely made up of stainless steel S/S 16 gauze # 304 Stainless Steel Mounted on four strong wheels with two movable front wheels with a turning radius of 90 degree both side. The wheels should be strong enough to bear the weight should not cause friction or noise and made up of solid rubber. There should be handle on the front side for pulling. High grade stainless steel sheet on the table top rounded beyond the borders to prevent injury to the animals and accumulation of blood etc. 33 VPP-01 34 VPP-02 35 VMC-01 36 VMC-02 All Glass double All Quartz double distillation Unit with power supply setup: distillation sets Demountable boiler panel series, vertical model, 2.5 lit/hr capacity, electrical requirement- 230-250 volts, single phase 4.4 kw, Minimum cooling water- 2 lit/min, distillate quality- pyrogen free, less than 1X10-6S/cm conductivity, less than 500 microgram total organic carbon, less than 0.1 mg/ lit total solids, 0 mg/lit organic matter, 0.007 UV absorbance at 254nm;total plate count, standard plate count, yeast and mould all zero. Gel Electrophoresis Horizontal Electrophoresis midi system : system (Horizontal) Gel dimension: 10 x 7cm & 10 x 10cm UV Tray, 2 x 16 with power pack sample combs, loading guides and dams, Unit dimension:12.5 x 22 x 9cm, Max. sample:10 x 7cm tray – 50 samples, Buffer volume: 300ml, Combs available(No. of samples):1, 2, 4, 8, 10MC, 12, 16, 20MC, 25; Adhesive Loading Guides; Viewing Platform; 10cm UV Gel Scoop; Buffer Saver Blocks; Horizontal Electrophoresis mini system : Gel dimension: 7 x 7cm &7 x 10cm UV Tray, 2 x 8 Sample combs, loading guides and dams, Unit dimension:9 x 21 x 9cm, Max. sample:7 x 7cm tray – 32 samples, 7 x 10cm tray – 64 samples, Buffer volume: 225ml, Combs available(No. of samples):1, 2, 4, 8MC, 8, 10, 12MC, 16; Adhesive Loading Guides; Viewing Platform; 7 cm UV Gel Scoop; Buffer Saver Blocks; Power supply system: Voltage Range: - 5-600v in 1V steps Current Range: - 5-500mA in 1mA steps Operation Modes: - Constant Voltage, constant current Display: - LED display Electronic Balance Fully microprocessor based with full tare facilities and LCD display and FACT calibration facility. Maximum capacity: 200 g. Readability: 0.01 mg. Repeatability: 0.03 mg. Linearity: 0.2 mg. Weighing pan diameter: 80-100 mm Warranty & Pricing: Warranty should be at least 2 years from the date of installation. Price should be quoted FOR Selesih including all the handling and clearing charges and it is to be done by the supplier. BOD Incubator Capacity 224 Litres Should be double walled, in which inside should be made of thick anodized aluminium/ stainless steel and outside of Mild Steel Sheet furnished in Epoxy Powder Coating. There should be minimum gap of 75mm between two walls to be fitted with pure mineral wool. Synthetic rubber gasket should be provided on the door for better grip. The incubator should have double door, in which outer 37 VMC03 Horizontal Submarine Electrophoresis system,, mini-gel 38 VMC04 Laboratory Egg Incubator: (100 to 200 eggs capacity setter–cumHatcher) should be metal door and inside should be glass door in stainless steel frame. Heating elements should be placed in ribs at the bottom and sides. Two adjustable air ventilators should be placed near the top of the sides. The temperature should be controlled by an Electronic Microprocessor Temperature Controller cum Indicator from ambient to 700C with sensitivity of plus minus 0.50C. Should be supplied with 2 pilot lamps, air circulating fan, perforated 4 (four) shelves (SS) adjustable at any level, having arrangement to fit the automatic timer to work on 220/230 volts AC only with cord and plug. Warranty & Pricing: Warranty should be at least 2 years from the date of installation. Price should be quoted FOR Selesih including all the handling and clearing charges and it is to be done by the supplier. Mini plus submarine gel units (10x11.5 CM gel length) Buffer chamber assembly UV transparent running tray Surface level detector Tape less gel casting facility Multiple combs, 8 wells, 12 wells and 16 wells Should be supplied with silicon gasket, high voltage leads, colored loading strips Power supply: 10-300V, 4-500mA, 90W with the options for minimum two simultaneous gel run. Warranty & Pricing: Warranty should be at least 2 years from the date of installation. Price should be quoted FOR Selesih including all the handling and clearing charges and it is to be done by the supplier. Setter trays:- Chicken eggs: >100; Goose eggs: >50; Duck eggs: >75, Bird(pigeon) eggs : >200. Hatcher tray: suitable for hatching the eggs specified for the setter tray(s). Egg candler: Suitable for candling the different eggs in place in the setter trays at different time of egg incubation without removing from the trays as a standard accessory Voltage: 220V /230V±2% stabilized by automatic electronic main line (120V to 280V) single phase voltage stabilizer > 5KVA with high and low voltage cutoff Hatching rate: Above 96% based on fertility determination by candling on 10th day of incubation Functions: Full-automatic electronic/ microprocessor controlled egg Incubator for setting and hatching Chicken, Bird (pigeon), Duck, Turkey, Quail, Goose eggs with preferably energy-saving and environment protection certification. Technical Parameters: Range of temperature adjustment: 5~50°C with0 .01°C increment Precision temperature control: ±0.05°C. Range of humidity display: 0~99%RH Turns of egg turning: Max turnings recordable up to 999 times Time interval of egg turning: Adjustable between 0.1 to 99.9 hours Time interval of ventilation: Adjustable between 5 and 999 minutes Ventilation Time: Adjustable between 0 and 999 second. Quality Assurance: CE certification Power back up: 3 KVA(power factor ≥0.8 with generator compatibility) on-line UPS capable of handling at 60% load 110-300 Volt input voltage with surge protection and ≥8 numbers 42AH SMF batteries not older than 4months at the time of supply (Emerson/APC/Fuji) Warranty: 24months comprehensive warranty from the date of installation. 39 LPT-01 Laminar Flow 40 LPT-02 41 LPT-03 Defeathering Machine Salting Instruments (Brine Injector) 42 VOG-01 43 VOG-02 44 VOG-03 45 VOG-04 46 VPA-01 47 VPA-02 Vertical, 0.3 microns HEPA Filters, 99.97% filtration efficiency Work table covered with Stainless Steel, Fitted with Static pressure Indicator (Manometer). Air velocity between 0.4 to 0.5 mls + - 20% Stabilisation through UV - Germiciadal Tubes Size 25(2"x2" or irxtrx4" Specification: 15 birds at a time, stainless steel (food grade), Motor capacity – 1 HP; Rubber pluckers of export quality. Stainless steel cover, high power resources, integrated pressure control with manometer, suck-in-device with pre filter device, integrated feed back system, easy and thorough cleaning, low power consumption, quick change of injection needles, glycerin-filled manometer 0-6 bar, injection needles from stainless steel 200x4mm, injection pistol from metal, chromium plated, Motor output: 0.5 KW/CA .5BAR Voltage: 400V, 50Hz, 3PH Dimensions: 390x180x240 MM With metal injection pistol, single as well as multiple needle – 200 x 4 mm, 2 needle pork S.S. 150 X 4 MM; 3 needle pork S.S. 150 X 4 MM; Stereo zoom Stereo zoom Microscope: Optical Trinocular Body, Microscope zoom ration 1:7, objective zoom range 0.65X-4.5X with high point super wide field eyepiece, minimum working distance 100 mm with a detached high resolution camera and display, head inclination 450with top halogen lamp and auxiliary lenses of 1.5X and 2.0 X Electric Sterilizer: Electric Sterilizer: Export Quality Stainless Steel fitted with Immersion Heater 24x12x12” Triple Glass Dist. Water output: 2.5 lit/hr Distillation set. Electrical requirements: 230-250 volts, single phase 4.4 kw Biological activity: Pyrogen free, Conductivity S/cm: <1X10-6, Total organic Carbon μg/l: <500, Organic matter mg/lit: Nil, Total solids: <0.1 mg/lit, Distillate Temp.: 6575ºC, Total plate count: 0, Standard plate count: 0, Yeast and Mould: 0, UV absorbance at 254 nm: 0.007 pH Meter Benchtop meter with DIN socket with electrode. AC or battery operation. Meter with universal power supply Buffer 4, 7 and 10, 01, 3 mol/1 KCL Horizontal Electrophoresis unit with casting tray 7 x 7 cm with Spare Electrophoresis casting tray 7 x 10 cm system with power Electrophoresis power supply unit. It should run two to pack four units at constant voltage or constant current with maximum output of 10–500 V, fully adjustable in 1 V steps,400mA and 80 Watts. Time can be set in 1 minute increment or continuous mode with all digital display. Should have safety features like no-load detection, sudden load change detection, ground leak detection, overload/short circuit protection, overvoltage detection, input line protection, auto power-up after power failure, Operating conditions like 0–40°C, 0–90% humidity in the absence of condensation, etc. Stereozoom Optical System should have Greenough optical system, Microscope Total Magnification ranging from 3.35-600x, Eyepiece inclination should be minimum 450 , Eyepieces C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 48 VPA-03 49 VPA-04 50 ANN-01 51 ANN-02 52 ANN-03 30x with diopter adjustment, Zoom Range 0.67-11x, Zoom Ratio 7.5:1, Working Distance should be more than 110mm, this system should be equipped with a camera port with Cmount adapter with digital camera and monitor system enabling image capture. Operating Environment should withstand high humidity. Proper power backup system should be supplied along with the machine. Compound Optical system should be UIS with 6V 30W halogen bulb, Microscope voltage should be 220-240V, Nose piece should have (Trinocular) universal revolving type, observation tube with super wide field with 3 position trinocular type, inclination upto 45o, specimen holder should have the provision for 2 slide, condenser should be planachromat, objective range should be with 4x, 10x, 40x and 100x, should be antifungus treated, should withstand upto 90% humidity environment, it should be supplied with detachable digital consumer camera with monitor display system, should be supplied with extra bulb, shoild have co-observation facilities and power back-up system Double Distillation Automatic Cabinet Double Distillation Unit. High quality, unit Low Temperature Output all distil-on Distillation Plant should manufactured by using GE 214 Semiconductor grade Quartz for the Doubler Coil Condensor and boiler system, combined with a silica glass sheathed heating element . Should provides a high quality pirogen free output with conductivity < 0.4 µS/cm. The system should be designed for fully automatic operation. Further Features should be present like: Flow Control Safety , A Gate , Level , Reservoir Level Sensor , Output Water Capacity should be more than 2 ltr/hour. Power – 230 volt, 50 / 60 Hz, Single phase 3.4 kw. Equipment should be supplied with at least 2 Nos. 20 Ltr. Capacity Water Reservoir with Tap . Bomb Calorimeter Microprocessor based-operated through software & PC and should be supplied with PC and its accessories, Automatic feeding of Calorific values of ignition wire & cotton thread, Automatic firing in the Bomb Automatic Detection of maximum rise of Temperature, Automatic calculation of Water equivalent/ calorific values in each experiment, Automatic delivery of result data in report format, Automatic graph plotting between time vs, temperature. Battery backup for stirrer and Microprocessor unit (UOS),8interface to connect with computer, soft touch Key pad, auto firing , Detection of maximum rise of Temperature, LCD display with backlit 16 x 2 characters, compatible with USB/ serial port of PC. Hot Air Oven Double-walled inside made of thick anodized Stainless Steel and outside of Mild Steel furnished in Epoxy Powder Coating , gap between two walls is filled with pure mineral wool, provided with Synthetic rubber gasket on the door for better grip, Heating elements are placed in ribs at the bottom and sides, Adjustable air ventilators near the top of the sides, temperature controlled by and Electronic Digital controller cum indicator form room /few ºC above ambient to 250ºC with sensitivity of plus minus 0.5 deg. C, supplied complete with two pilot lamps, p[perforated shelves adjustable at any level having arrangement to fit the automatic time to works on 220/230 volts A.C. cord and plug . Completer with air circulating fan Size: 605X605X910mm (336Ltrs.) Muffle furnace Microprocessor PID controller having 4 ramp & soak profile having set mode, made of thick mild sheet having 53 ANN-04 54 AGB-01 55 AGB-02 powder coated in good looking colour, Ceramic Fibre blanket for high density for better insulation, provide with Stainless-steel 310 Qlty. Base plate to safe guard the interior chamber Heating Elements are made of special Kanthal wire to make furnace working continuously up to 1150ºC, fitted with fine quality Digital indicator cum controller to work on 220Volt AC 50Hz, size: 300 X 300 X 605 mm. Automatic Kjeldah Microprocessor based, PC compatible, Auto mode Nitrogen programmable-5-35ml manual mode continuous, alkali tank Distillation system capacity-2 Litres, peristaltic pump with spring loaded rotor and anti-corrosive pump head for alkali addition. Distillation time programmable, distillation capacity-12-25 sample/hr,steam generator stainless steel with water level View window, auto electronicsmicroswitch controller for water level. Automatic replacement of steam by a balancer devise, steam capacity constant by thermostatic preheating mechanism, auto readysignal for steam processing nitrogen recovery -99.5-100%, Electrical requirement: 220v/50Hz, Automatic sample dilution, automatic and manual alkali addition digital real time count down, Automatic KMno4for available nitrogen facility, automatic error diagnostic features. pH Meter 1. Should have Working range from 0 to 14. 2. Should have resolution 0.1/0.01 pH. 3. Should have Temperature compensation zero to 100 degree C with ATC 4. Should have RS.232C output and supply Data connector cable. 5. Should have Automatic calibration facility. 6. Should have data storage facility and record maximum and minimum value. 7. Should have 3 stage calibration. 8. Should have digital display with 0.001 pH unit readability 9. Should supply Tri-combination pH/ATC electrode 10. Should supply Electrode + Standard buffer solution (pH 4.0, 7.0, 10.01 x 50ml for each bottle) + standard electrode holder +Ac /DC Adaptor. 11. Should be provided with an electrode holder/arm with smooth movement. Autoclave 1. Should have a triple walled construction. 2. The working chamber, steam jacket, outer chamber and the lid should be made of stainless steel. 3. Should have water inlet and outlet valves. 4. Should have a water level gauge 5. Should have gauges for measuring inner and outer steam pressure. 6. Should have an inner temperature indicator. 7. Should have automatic pressure control switch, safety valve and eject valve. 8. Should have joint-less silicone gasket. 9. Should have automatic low water protection. 10. Should be supplied along with bins. 11. Should have an ISI mark. 12. Should have 121ºC working temperature at 15 to 20 psi pressure. 13. Chamber volume should be approximately 300mm diameter and 500mm depth with minimum 2 bin type. 14. Should be operated in mains 220 – 240 V ac 50 Hz input power supply. 15. Water inlet and outlet pipe should be provided and connections should be done on a turnkey basis. 56 VHE-01 57 VHE-02 58 LPM-01 LPM-02 59 60 LPM-03 61 LPM-04 62 LPM-05 63 LPM-06 64 LPM-07 65 LPM-08 66 LPM-09 67 LPM-10 68 LPM-11 69 LPM-12 LCD Data Projector LCD Data Projector Resolution: 1280X800 pixel, Brightness: 3200 ANSI, Contrast: 2500:1, Connectivity:HDMI, S-Video, USB, Aspect Ratio: 4:3 INFORMATION INFORMATION KIOSK KIOSK Display Display (a) Type : Colour LCD (b) Size : 48.3 cm (19 inches) (c) Resolution : 1280 x 1024 (d) LCD Touch Panel : Minimum 250 CD/m2 (NITS) brightness System Details (a) Processor :Embedded processor, 2.0 GHz or higher 3 MB Cacheor higher. (b) Memory : 2 GB or higher (c) HDD/Storage :250 GB or higher (d) Audio : 1 x Line-out/1 Line-in (e) Speaker : 2x1.5 Watt, RMS Stereo speaker. (f) Operating System : Windows 8 Professional with USB based keyboard Debreaker with Electrically operated, brass blade, cuts beak and cauetieses stand in a single operation AI Equipment set AI Equipment set for-pig, cow and goat for different species Milk Packing For Milk, Water, lassi, Juice, Virgin multilayer co-extruded Machine L.D.P.E film, Fill quantity: 200 ml to 1000ml, Gravity filling electromagnetic system, 2500 Pouches per hour, Impulse sealing, Standard vertical overlap, accuracy: +-2% up to 500ml, electric supply single phase, 50 Hz, 230 V+1% and neutral connection to connected load 4 KW Automatic scalder 18”DIA. With temp guage & gas fittings and stainless steel cover. 1HP motor De-feathering Without door, gear box model 0.5 hp, 1 Phase approx.. Machine Load Capacity- 7.5 kg. Digital Weighing Accuracy-10mg.(approx.), electric and battery operated, Balance (300kg) platform type (minimum 10cm diameter) Digital Weighing Accuracy-5g(approx.), electric and battery operated, Balance (30kg) platform type (size-30cmx20cm minimum) Weighing Balance Spring/mechanical, Pan type: pan size-15cm x 15cm (Spring) (minimum), dial type, made of metal (for 10&20kg) 2kg,5kg,10kg,20kg Water Distillation Single distillation unit made of glass, distilled water outputapparatus 4lit/hr, electrical requirement:230-250 volts, single phase 3.5kw, quartz heater, cool water consumption-not more than 70 lit/hr, distilled water pH 6-7, pyrogen free. Milking Machine Vacuum and Massage technique with help of Aero Pulsator (Bucket Type) with pulse rate of 60ppm & Pulsation Ratio 65:35 and Double special cluster MC11. Trolley type. Back Fat scanner Range/Accuracy:4-35mm (0.156”-1.365”) +/-1 digit for pig Display # 2-digit LED for thickness 3 LED’s to indicate 1,2 or3 layers being measured Baterry charging LED Controls: On/Off push button Power supply: Nickel Metal Hydride battery Battery Pack Life: approximately 2-4 years (1000 charges/discharges) Milk Analyser For measurements of fat and SNT in raw cow and buffalo milk Ability to screen for non-pure milk, Detection of specific adulterants Easy to use, self-contained instrument 70 LPM-14 71 LPM-15 Measurement results can be transferred directly to PC via RS232, eliminates human sources or readings, Replaces manual and time consuming Gerber and Lactometer methods, Logging of all operations available. Accessories Adaptor, 4 GB Memory Card. Clean solution Descalding Solution Clean Bottle-1ltr. Zero Bottle-1ltr. Descalding Bottle-15oml. RS-232 Cabfle Manual Clean Kit PM Kit Quick Guide Instrument Bag Napkin Measuring Cups Descaling Cup Identification tags Tags numbered on both sides, made of nylon flex. for goats, pigs and cattle Quail egg setting Capacity – 90 eggs, made of good quality plastic. tray