Nutec Design Associates Architectural Department Drawing and Design Checklist Job Name: Click here to enter text. Job Number: Click here to enter text. Job Code: Click here to enter text. Lead Designer: Click here to enter text. Date Reviewed: Click here to enter text. Dept. Mgr. (Or Checker): Click here to enter text. Date Reviewed: Click here to enter text. Drawings Issued: Click here to enter text. COVER SHEET ☐ PROJECT TITLE ☐ DRAWING LIST OF ALL DISCIPLINES ☐ CORRECT CLIENT / PROJECT NAME ☐ VERIFY ALL DRAWINGS IN PACKAGE MATCH DRAWING LIST ☐ CORRECT CLIENT / PROJECT ADDRESS ☐ PROJECT STATUS ☐ PROJECT NUMBER ☐ CORRECT LEAD COMPANY NAME, LOGO, PROJECT NUMBER (NTD, JDB, NCF) ☐ DATE ☐ REVISION NUMBER ☐ SITE LOCATION MAP WITH BUILDING / SITE LABELED ☐ SYMBOLS LEGEND – NEW OR UNIQUE SYMBOLS ADDED ☐ ABBREVIATIONS – NEW OR UNIQUE ADDED ☐ SHEET LABELED AS ‘G001’ ☐ PROPER TITLE BLOCK FOR GOVERNMENT PROJECTS ☐ Drawings in correct order per Discipline OVERALL FLOOR PLANS ☐ KEY PLAN ☐ MATCH LINES ☐ NORTH ARROW ☐ CALLOUT BUBBLES REFERENCING LARGER SCALED PLANS ☐ PLAN TITLES AND SCALES ☐ SITE FEATURES IMMEDIATELY ADJACENT TO BUILDING ☐ SCALED TO FIT ON ONE SHEET ☐ ROOM TAGS ☐ LEGEND FOR UNIQUE ITEMS (EXISTING VS NEW CONSTRUCTION) LIFE SAFETY PLANS ☐ KEY PLAN ☐ FIRE / SMOKE WALLS AND BARRIERS (Ratings) ☐ NORTH ARROW ☐ SIGNAGE LEGEND REVIEWED AND UPDATED ☐ PLAN TITLES AND SCALES (SIGN TYPES) ☐ CODE STUDY COMPLETED ☐ REVIEWED AND UPDATED LIFE SAFETY SYMBOLS (FIRE WALLS, BOILIER ROOM, ELEVATOR, ELECTRICAL ROOM, MACHINE ROOM, ETC) f:\forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. ☐ TOILET ROOMS (MENS, WOMENS, FAMILY, UNISEX) ☐ LOCKER ROOMS (MENS, WOMENS, FAMILY) ☐ EXIT SIGN Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist ☐ ASSEMBLY MAXIMUM OCCUPANCY ☐ EGRESS DOOR SEPARATION DISTANCE PER CODE ☐ OTHER MAXIMUM OCCUPANCY ☐ FIRE RATED DOORS LABELED (REFERENCED TO DOOR SCHEDULE) ☐ STAIRS ☐ ELEVATOR ☐ EGRESS PATH AND DISTANCE ☐ IN CASE OF EMERGENCY (AT ELEVATOR) ☐ ACCESSIBILITY CHART REVIEWED ☐ AREA OF RESCUE WITH INSTRUCTIONS ☐ ACCESSIBLE PATH TO PUBLIC WAY ☐ AREA OF REFUGE WITH INSTRUCTIONS ☐ FIRE EXTINGUISHERS AND CABINETS ☐ STAIR TOWER FLOOR LEVELS ☐ TOP AND BOTTOM LEVELS OF STAIR TOWER ☐ FIRE EXTINGUISHER TYPES LABELED (KITCHENS, ETC) ☐ EXIT DISCHARGE LEVEL ☐ ROOM TAGS ☐ NON-EXITS ☐ EXIT MAPS ☐ MATCH LINES AND LABELS (IF PLANS ARE BROKEN) ☐ DIRECTIONAL SIGNAGE (IBC SECTION 1110) ☐ OCCUPANCY COUNT FOR EACH AREA/ROOM ☐ AT INACCESSIBLE ENTRANCES ☐ INCHES OF EGRESS WIDTH REQUIRED AND PROVIDED AT EACH EXIT ☐ AT INACCESSIBLE PUBLIC TOILETS ☐ PROPER CORRIDOR EGRESS WIDTH PER CODE ☐ LOCATION OF ACCESSIBLE EXITS (MAP) ☐ NO DOOR SWINGS BLOCKING CORRIDOR ☐ SIGNAGE FOR FIRE RATED WALLS ☐ PROPER STAIR AND RAMP WIDTH PER CODE ☐ AT INACCESSIBLE ELEVATORS NOT SERVING ACCESSIBLE ROUTE ☐ RAMP SLOPE AND DISTANCE ☐ RAMP LANDINGS ☐ SIGNAGE SIZES AND DIMENSIONS FROM FLOOR ☐ OVERHEAD EXIT SIGNAGE (COORDINATE WITH ELECTRICAL) ☐ TACTILE AREAS SHOWN ON SIGNS ☐ EMERGENCY LIGHTING (COORDINATE WITH ELECTRICAL) ☐ PLANS LABELED WITH SIGNAGE LOCATIONS ☐ PROPER NUMBER OF EGRESS DOORS PER CODE DEMOLITION PLANS ☐ KEY PLAN ☐ COORDINATED M/E/P DEMOLITION ITEMS ☐ NORTH ARROW ☐ DASHED LINES OF OBJECTS TO BE DEMOLISHED ☐ PLAN TITLES AND SCALES ☐ DEMOLITION TAGS ☐ DEMOLITION GENERAL NOTES ☐ ROOM NAMES ☐ DEMOLITION TAG LEGEND ☐ FIRE AND SMOKE WALLS AND BARRIERS ☐ DEMOLITION CEILINGS ☐ MATCH LINES ☐ DEMOLITION FLOOR MATERIALS f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. 2 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist FLOOR PLANS ☐ KEY PLAN ☐ PUSH / PULL CLEARANCES AT ALL DOORS ☐ NORTH ARROW ☐ SOUND BATT AT STUDDED RESTROOM WALLS AND WHERE APPROPRIATE ☐ PLAN TITLES AND SCALES ☐ SITE FEATURES IMMEDIATELY ADJACENT TO BUILDING ☐ PIPE BOLLARDS ☐ FINISHED FLOOR ELEVATIONS INDICATED (SPOT ELEVATIONS WHERE APPROPRIATE) ☐ FLOOR TRENCHES, PITS ☐ FLOOR GRATING ☐ ROOF DRAIN LEADERS (REFERENCED TO APPROPRIATE DISCIPLINE) ☐ STRUCTURAL COLUMN GRID(coordinate w/ Struct.) ☐ PLUMBING FIXTURES (TOILET/SHOWER PARTITIONS, URINAL SCREENS) ☐ DOWNSPOUTS ON BUILDING EXTERIOR ☐ FLOOR DRAINS AND SLOPE OF FLOORING ☐ OVERHEAD CONSTRUCTION (BALCONIES, MEZZANINES, CANOPY OVERHANGS) ☐ RECESSED DOOR MATS ☐ MOP SINK ☐ FIXED LADDERS ☐ GRAB BARS ☐ RAMPS WITH RAILINGS, SLOPE WITH DIRECTIONAL ARROW. ☐ ABMULATORY STALL PER CODE ☐ NEW/EXISTING CONSTRUCTION INDICATOR ☐ FAMILY RESTROOM PER CODE ☐ RAISED ACCESS FLOOR SYSTEM ☐ DRINKING FOUNTAINS / WATER COOLERS ☐ LOCKERS/BENCHES ☐ CASEWORK/COUNTERTOPS (Elev. Designantions) ☐ LOCKERS FOR EACH SEX PER CODE ☐ FLOORING PATTERNS AND/OR CHANGE OF MATERIAL ☐ ADA LOCKERS/BENCHES LABELED ☐ ACCESS HATCHES, SCUTTLES AND/OR DOORS ☐ FIRE HOSE CABINETS (If Req’d) ☐ SHELVING AND ROD/SHELF LOCATIONS ☐ SMOKE CURTAINS (If Req’d) ☐ RAILINGS (STAIRS, BALCONIES, LANDINGS, RAMPS, OPENINGS) ☐ SMOKE/FIRE VENTS (ROOF MOUNTED) ☐ TRANSFORMERS, PANEL BOXES, AND TELEPHONE BOARDS (REFERENCED TO APPROPRIATE DISCIPLINE) ☐ VENDORS EQUIPMENT SIZES ☐ FIRE EXTINGUISHERS / CABINET LOCATIONS PER CODE ☐ GENERAL NOTES ☐ ADA LOCKER ROOM BENCH WITH BACK ☐ ADA SIGNAGE AND LOCATION SCHEDULE ☐ N.I.C. NOTE WHERE APPLIES ☐ CONCRETE PADS AT EXITS ☐ FIRE EXTINGUISHER CLASS AND LABEL FLOOR PLANS - REFERENCES ☐ PARTITION TYPES U.L. WALL RATINGS WHERE REQUIRED ☐ DOOR REFERENCE NUMBERS ☐ WINDOW REFERENCE NUMBERS (EXTERIOR) ☐ ROOM NAMES AND NUMBERS f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. 3 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist ☐ BORROWED LIGHT REFERENCE NUMBERS (INTERIOR) ☐ INTERIOR ELEVATION ARROW SYMBOLS AND REFERENCE NUMBERS (IF NOT INDICATED ON ENLARGED PLANS) ☐ WALL SECTION LINES AND REFERENCE NUMBERS ☐ LINTEL REFERENCE NUMBERS ☐ BUILDING SECTIONS LINES AND REFERENCE NUMBERS ☐ MATCH LINE INDICATOR ☐ FIRE / SMOKE WALLS AND BARRIERS ☐ DETAIL CALLOUTS AND REFERENCE NUMBERS ☐ LARGE SCALE PLAN REFERENCES (RESTROOMS, STAIRS, ELEVATORS) FLOOR PLANS - DIMENSIONS ☐ OVERALL BUILDING DIMENSIONS ☐ ALL CRITICAL INTERIOR DOORS AND WINDOWS ☐ ALL EXTERIOR OFFSETS IN BUILDING PLAN ☐ SPECIAL EQUIPMENT LOCATIONS ☐ STRUCTURAL COLUMN GRID ☐ FLOOR PITS AND/OR PLATFORMS ☐ EXTERIOR DOOR LOCATIONS (OPENING WIDTH OR CENTER LINE) ☐ FLOOR TRENCHES ☐ PLUMBING FIXTURE LOCATIONS (If not indicated on enlarged plans) Verify clearances ☐ EXTERIOR WINDOW LOCATIONS (OPENING WIDTH OR CENTERLINE) ☐ ADA 5'-0" TURNING RADIUS ☐ ALL BEARING WALL LOCATIONS ☐ MASONRY DIMENSIONS FOR MASONRY WALLS AND OPENINGS ☐ ALL INTERIOR PARTITIONS (EXCEPT THOSE INDICATED ON ENLARGED PLANS) ROOF PLANS ☐ KEY PLAN ☐ NORTH ARROW ☐ DOWNSPOUT SIZES AND RAIN LEADER LOCATIONS ☐ PLAN TITLES AND SCALES ☐ SCUPPERS ☐ OVERALL BUILDING DIMENSIONS (LENGTH, WIDTH AND OFFSETS) ☐ EXPANSION JOINTS ☐ STRUCTURAL COLUMN GRID WITH COLUMN DESIGNATION BUBBLES ☐ SMOKE/FIRE VENTS ☐ ROOF SLOPES, HIPS/VALLEYS ☐ PARAPETS ☐ TAPERED INSULATION LAYOUT/THICKNESS ☐ PLUMBING STACKS/VENTS ☐ ROOF DRAINS (REFERENCE TO APPROPRIATE DISCIPLINE) ☐ MECHANICAL EQUIPMENT ☐ SKYLIGHTS ☐ EXPLOSION RELIEF VENTS ☐ EQUIPMENT ROOF CURB DETAIL ☐ ROOF GUTTERS AND SIZE ☐ EXPOSED DUCTWORK ☐ CHIMNEY/FLUE f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. 4 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist ☐ SNOW GUARDS ☐ ROOF CURBS ☐ ROOF LADDERS/STAIRS ☐ EQUIPMENT SUPPORTS ☐ ROOF LADDER DETAIL AT LADDER BASE ☐ MAJOR FEATURES OF ROOF DIMENSIONED ☐ LIGHTNING PROTECTION ☐ WALL SECTIONS CROSS-REFERENCED ☐ ROOF HATCHES/SCUTTLES ☐ BUILDING SECTIONS CROSS-REFERENCED ☐ ROOF TOP PRECAST CONCRETE PAVER WALKWAY ☐ ROOF MATERIALS INDICATED ☐ WALKWAY TREADS ☐ FLASHING ☐ GUARD RAILS AT ROOF EDGES REFLECTED CEILING PLANS ☐ KEY PLAN PLAN (DIMENSIONED) ☐ NORTH ARROW ☐ MECHANICAL SHAFTS ☐ PLAN TITLES AND SCALES ☐ SOFFITS AND BULKHEADS WITH SECTION DETAIL ☐ STRUCTURAL COLUMN GRID WITH COLUMN BUBBLES LABELED ☐ METAL ACCESS PANELS ☐ ROOM TAGS ☐ LIGHTING FIXTURE LOCATIONS (Coord w/ Elec) ☐ CEILING HEIGHTS INDICATED ☐ SPRINKLER HEAD LOCATIONS (Coord w/ F.P.) ☐ OVERALL BUILDING DIMENSINS (LENGTH AND WIDTH) ☐ HVAC AIR DEVICE LOCATIONS (Coord w/ MECH) ☐ NOTE WHERE ROOMS ARE OPEN TO STRUCTURE ABOVE ☐ CONTROL JOINTS IN MEMBRANE CEILINGS (EX. GYPSUM BOARD, CEMENT, PLASTER, ETC.) ☐ INTERIOR PARTITIONS WHICH DO NOT PENETRATE CEILING PLANE ☐ SKYLIGHT DETAILS ☐ EXPANSION JOINTS ☐ FIRE AND SMOKE WALLS AND BARRIERS (INDICATED WITH HIDDEN LINES) ☐ CURTAIN TRACKS ☐ ALL PENETRATIONS IN INTERIOR PARTITIONS THAT OCCUR ABOVE CEILING EXTERIOR ELEVATIONS ☐ DRAWING TITLES AND SCALES (ELEVATION VIEW OR NUMBER) ☐ BUILDING CROSS SECTION LINES AND REFERENCE NUMBERS ☐ COLUMN CENTERLINES WITH COLUMN DESIGNATION BUBBLES LABELED ☐ WALL MATERIAL INDICATIONS ☐ KEY PLAN ☐ EXISTING AND NEW GRADE LINES AT BUILDING FACE INDICATED ☐ ROOF MATERIAL INDICATIONS ☐ OUTLINE OF EXISTING ADJACENT STRUCTURES ☐ WALL SECTION LINES AND REFERENCE NUMBERS f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. ☐ DOWNSPOUTS, GUTTERS AND SIZES ☐ ALL ELEVATIONS INCLUDING AREAS ON ROOF 5 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist EXTERIOR ELEVATIONS - ELEVATION DIMENSIONS/ELEVATIONS ☐ FLOOR-TO-FLOOR DIMENSIONS ☐ ELEVATIONS OF EXTERIOR STAIR LANDINGS ☐ HEIGHT OF PARAPET WALLS ☐ FINISHED FLOOR ELEVATIONS INDICATED WITH BULLET ☐ HEIGHT OF EAVES ☐ HEIGHT OF EQUIPMENT ☐ ROOF SLOPE (PITCHED ROOFS) ☐ ELEVATION LEVELS COORDINATED WITH OTHER DISCIPLINES ☐ ELEVATIONS OF EQUIPMENT PLATFORMS EXTERIOR ELEVATIONS - BUILDING OPENINGS ☐ DOORS TAGS ☐ SCUPPERS ☐ WINDOWS TAGS ☐ VENTS, EXHAUST FANS, ETC. (Coord w/ MECH) ☐ LOUVERS (Coord w/ MECH) EXTERIOR ELEVATIONS - STRUCTURAL ELEMENTS ☐ PILASTERS ☐ CONTROL JOINTS ☐ EXTERIOR COLUMNS, PIERS AND FOUNDATIONS BELOW GRADE (Coord w/ Struct) ☐ EXPANSION JOINTS ☐ RETAINING WALLS ☐ PARAPETS (SHOW ROOF LINE) EXTERIOR ELEVATIONS - MISCELLANEOUS ☐ SIGNS AND/OR LETTERS ☐ SKYLIGHTS ☐ GUTTERS AND DOWNSPOUTS ☐ RIDGE VENTS ☐ PIPE BOLLARDS ☐ RAIN DEFLECTORS ☐ STOOPS, STEPS, RAMPS WITH RAILINGS ☐ SNOW GUARDS ☐ CANOPIES, AWNINGS ☐ AREAWAYS WITH RAILINGS ☐ CHIMNEYS/FLUES ☐ CORNER GUARDS EXTERIOR ELEVATIONS - MECHANICAL/ELECTRICAL ☐ LIGHT FIXTURES ☐ ROOF MOUNTED EQUIPMENT BUILDING CROSS SECTIONS ☐ KEY PLAN ☐ SECTION TITLES AND SCALES f:\forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. ☐ FINISHED FLOOR ELEVATIONS INDICATED WITH BULLET Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist ☐ COLUMN WITH COLUMN BUBBLES LABELED ☐ COLUMNS AND POSTS (Coord w/ Struct) ☐ FOUNDATION CONSTRUCTION (Footings, walls, piers, grade beams ) (Coord w/ Struct) ☐ SKYLIGHTS ☐ STRUCTURAL SYSTEM (Coord w/ Struct) ☐ AREA WAYS ☐ EXTERIOR WALL CONSTRUCTION ☐ ADJACENT PAVING, WALKS, GRADES ☐ FLOOR CONSTRUCTION ☐ EXTERIOR SLAB FOOTINGS OR FROST WALLS ☐ ROOF CONSTRUCTION ☐ FOUNDATION DRAINS ☐ ROOF SLOPE(S) ☐ DAMPPROOFING OR WATER PROOFING ☐ INTERIOR WALL ☐ OTHER BUILDING CROSS SECTIONS CROSSREFERENCED ☐ LIGHT WELLS ☐ ROOM NAMES AND NUMBERS BUILDING CROSS SECTIONS - DIMENSIONS ☐ FLOOR-TO-FLOOR DIMENSIONS. ☐ ROOF OVERHANG DIMENSIONS. ☐ FLOOR-TO-CEILING DIMENSIONS. ☐ PARAPET HEIGHT DIMENSIONS. ☐ FLOOR-TO-ROOF STRUCTURE DIMENSIONS. ☐ CRITICAL CLEARANCE DIMENSIONS. WALL SECTIONS ☐ KEY PLAN ☐ FLOOR CONSTRUCTION (SLAB-ON-GRADE AND ELEVATED FLOORS) ☐ SECTION TITLES AND SCALES ☐ FINISHED FLOOR ELEVATIONS INDICATED WITH BULLET ☐ ROOF CONSTRUCTION ☐ COLUMN WITH COLUMN BUBBLES LABELED ☐ PARAPET/ROOF CONSTRUCTION ☐ FOUNDATION CONSTRUCTION (FOOTINGS, WALLS, PIERS, GRADE BEAMS) ☐ GRAVEL STOP/ROOF CONSTRUCTION ☐ ROOF SLOPE ☐ GUTTER/ROOF CONSTRUCTION FOUNDATION DRAINS ☐ STRUCTURAL SYSTEM (COLUMNS, BEAMS, JOISTS, ETC.) ☐ DAMPPROOFING OR WATERPROOFING ☐ EXTERIOR WALL CONSTRUCTION (MATERIALS, REINFORCING, INSULATION) ☐ THRU-WALL FLASHING WALL SECTIONS - DIMENSIONS ☐ FLOOR-TO-FLOOR DIMENSIONS. ☐ FLOOR-TO-CEILING DIMENSIONS. ☐ WALL OPENING DIMENSIONS TO SILL AND HEAD (WINDOWS, DOORS AND LOUVERS, ETC.) ☐ FLOOR-TO-ROOF STRUCTURE DIMENSIONS. ☐ ROOF OVERHANG DIMENSIONS ☐ FLOOR-TO-HEADER OR LINTEL DIMENSIONS ☐ PARAPET HEIGHT DIMENSION ☐ TOP OF STEEL ELEVATIONS INDICATED WITH BULLET (Coord w/ Struct) f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. 7 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist ☐ LINES) WALL THICKNESS/WIDTH DIMENSIONS (INCLUDE CAVITY CONSTRUCTION) ☐ NOTE FIRE RATING WHERE REQUIRED AND SHOW RATED SEALANT AT TOP OF WALL, ONE SIDE ONLY TO STRUCTURE ABOVE ☐ WALL SECTIONS CROSS-REFERENCED AS NECESSARY ☐ STRUCTURAL COLUMN GRID WITH COLUMN BUBBLES LABELED ☐ INTERIOR ELEVATION ARROW SYMBOLS AND REFERENCE NUMBERS ☐ INTERIOR PARTITIONS DIMENSIONS BY CONTINUOUS STRINGS (INCLUDE PARTITION THICKNESS) ☐ BORROWED LIGHT REFERENCE NUMBERS ☐ TOILET PARTITIONS DIMENSIONED (Plans or Elevations – not both) ☐ PENETRATIONS IN INTERIOR WALLS DIMENSIONED (DOORS, BORROWED LIGHTS, ETC.) ☐ TOILET ACCESSORIES INDICATED (EDIT SCHEDULE) ☐ FLOOR DRAINS WITH SLOPE INDICATED (REFERENCE APPROPRIATE DISCIPLINE) ☐ CASEWORK AND COUNTERTOPS INDICATED ☐ MISCELLANEOUS DETAILS CROSSREFERENCED ☐ ADA 5-0 TURNING RADIUS (TOILET ROOMS) ☐ WALL LOCATION (DIMENSION OUTSIDE AND INSIDE FACE TO COLUMN CENTERLINE) ☐ MASONRY WALL HEIGHT DIMENSIONS (REFERENCE FROM FINISHED FLOOR ENLARGED PLANS AND INTERIOR ELEVATIONS PLANS ☐ PLAN TITLES AND SCALES ☐ ROOM NAMES AND NUMBERS ☐ PLUMBING FIXTURE LOCATIONS DIMENSIONED ☐ SHAFTS CLEARLY INDICATED AND DIMENSIONED ☐ PARTITION TYPES INDICATED ENLARGED PLANS AND INTERIOR ELEVATIONS - INTERIOR ELEVATIONS ☐ PLAN TITLES AND SCALES ☐ ☐ STRUCTURAL COLUMN CENTERLINES WITH BUBBLES LABELED TOILET PARTITIONS DIMENSIONED (Plans or Elevations – not both) ☐ WALL MATERIALS INDICATED ☐ TOILET ACCESSORIES DIMENSIONED (EDIT SCHEDULE) ☐ WALL MATERIAL LIMITS DIMENSIONED ☐ CEILING HEIGHTS INDICATED ☐ WALL MOUNTED ITEMS INDICATED (SHELVES, COAT RACKS, ETC.) ☐ MISCELLANEOUS SECTIONS CROSSREFERENCED ☐ CASEWORK AND COUNTERTOPS DIMENSIONED VERTICAL TRANSPORTATION - PLANS ☐ PLAN TITLES AND SCALES f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. ☐ ROOM NAMES AND NUMBERS 8 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist ☐ PLANS AT EACH FLOOR LEVEL ☐ STAIRS - HANDRAILS/GUARDRAILS INDICATED ☐ FINISHED FLOOR ELEVATIONS INDICATED ☐ STAIRS – HANDRAILS EXTENSIONS AT TOP AND BOTTOM ☐ STRUCTURAL COLUMN GRID WITH COLUMN BUBBLES LABELED ☐ STAIRS - DIRECTIONAL ARROWS INDICATED ☐ PARTITION TYPES INDICATED ☐ PENETRATIONS IN INTERIOR WALLS DIMENSIONED (I.E., DOOR OPENINGS) ☐ DOOR REFERENCE NUMBERS ☐ SECTIONS CROSS-REFERENCED FROM PLANS ☐ STAIRS - PLANS DIMENSIONED (STAIR RUNS, LANDINGS, WIDTHS, ETC.) ☐ FLOOR OPENINGS DIMENSIONED VERTICAL TRANSPORTATION - SECTIONS ☐ SECTION TITLES AND SCALES ☐ STAIRS - MAJOR STRUCTURAL ELEMENTS INDICATED ☐ FINISHED FLOOR ELEVATIONS INDICATED WITH BULLET ☐ STAIRS - ENLARGED DETAILS INDICATED (TREAD/RISER, HANDRAIL) ☐ STRUCTURAL COLUMN CENTERLINES WITH BUBBLES LABELED ☐ STAIR CONSTRUCTION ☐ WALL MATERIALS INDICATED ☐ LADDERS - DIMENSIONED ☐ FLOOR CONSTRUCTION INDICATED ☐DETAILS CROSS-REFERENCED FROM SECTIONS ☐ ROOF CONSTRUCTION INDICATED ☐ELEVATOR PIT WITH LADDER ACCESS ☐Rungs for ladder to be 4 ½” to 7” off pit wall ☐ FLOOR-TO-FLOOR DIMENSIONS INDICATED ☐ CRITICAL OVERHEAD CLEARANCE DIMENSIONS INDICATED ( ELEVATOR TRAVEL CLEARANCE) ☐ELEVATOR MACHINE ROOM ☐ Door must swing out ☐ STAIRS - SECTIONS DIMENSIONED (RISER HEIGHTS AT MID-LANDING ELEVATIONS) ☐ Fire Extinguisher ☐ No utilities running thru that do not serve elevator ☐ STAIRS - RAILINGS INDICATED AND DIMENSIONED ☐ STAIRS – RAILING EXTENSIONS TOP AND BOTTOM DRAWING NOTES – STYLE AND LANGUAGE ☐ NO PHRASES "CONTRACTOR SHALL…" "CONTRACTOR TO…" "CONTRACTOR IS RESPONSIBLE FOR…" ☐ NO NOTES IN THE INDICATIVE (PASSIVE) MOOD WITH THE TERM "SHALL BE". USE IMPERATIVE MOOD: "INSTALL EQUIPMENT LEVEL…" "SPREAD ADHESIVE WITH…" "APPLY INSULATION BEFORE…" ☐ NO REFERENCES TO WORK BY OTHER TRADES, I.E. "…BY G.C." "…BY E.C." USE INSTEAD "SEE ARCH. DWGS." "SEE ELEC. DWGS." ☐ STANDARD ABBREVIATIONS, ACCORDING TO SYMBOL SCHEDULE AND CONSISTENT USAGE f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. 9 Issued 04/11/12 Nutec Design Associates Architectural Department Drawing and Design Checklist TITLE BLOCKS ☐ PROJECT TITLE ☐ NUTEC LOGO AND PROJECT NUMBER ☐ DRAWING TITLE ☐ PROFESSIONAL’S SEAL AND SIGNATURE ☐ DRAWING NUMBER ☐ REVISION NUMBER ☐ DRAWING DATE ☐ DRAWING PHASE ☐ INITIALS IN ALL BOXES INTERDISCIPLINARY COORDINATION (WHEN THIS DISCIPLINE IS THE LEAD DISCIPLINE) ☐ PROJECT TITLE (COVER SHEET, DRAWINGS AND SPECIFICATIONS). ☐ SHEET NUMBERING SYSTEM ☐ KEY PLANS AND NORTH ARROWS ☐ PROJECT DATE (DRAWINGS AND SPECIFICATIONS) ☐ PLOT/PRINTING DATE SCHEDULED WITH REPROGRAPHICS ☐ DRAWING TITLES; CONSISTENT BETWEEN DISCIPLINES, AGREE W/ DRAWING LIST IN SPECIFICATIONS TABLE OF CONTENTS ☐ PLANS IN SAME ORDER AMONG ALL DISCIPLINES OTHER ☐ REVISION LEVEL SET TO “O”, OR AS NEEDED ☐ CHECK COPYRIGHT DATE FOR CURRENT YEAR ☐ TEXT SIZE AND STYLE ☐ START REVISION BLOCK ITEMS AT THE BOTTOM ☐ SPELL CHECK ☐ STRUCTURAL AND ARCHITECTURAL COLUMN GRIDS MATCH ☐ LINKED MODEL COORDINATION WITH OTHER TRADES f:\Forms\Checklst\A_dwgcklst.doc 2012 NuTec Design Associates, Inc. ☐ FLOOR LEVELS MATCH 10 Issued 04/11/12