the best dedicated THGA furnace system AAnalyst 600 AA

advertisement
AAnalyst 600
ES Hwang
Inorganic Product Specialist
PerkinElmer Korea
AAnalyst 600…

 Benefits
Features
•
•
•
Dedicated THGA furnace
High sensitivity segmented
solid-state photodiode
detector
Simultaneous measurement
of sample and reference
beams
 THGA furnace reduces
interferences in difficult matrices
 Exceptional analytical performance
and detection limits
 Highest Long-term Stability

Minimized interferences and
memory effects
• Transversely heated graphite
furnace

Shorter analysis time (fast furnace
programs)
• Longitudinal Zeeman effect
background correction

Best possible background
correction with no light loss
… the best dedicated THGA furnace system
AAnalyst 600
AA Spectrometers
AAnalyst 600
Revolutionary Optical System
AAnalyst 600
Unique Features
 First AA spectrometer
•
Integrated furnace
 Zeeman-THGA graphite furnace
AAnalyst 600
Unique Features
 First AA spectrometer
•
•
8-lamp holder
 Automatic lamp selection and adjustment
Built-in power supplies
 Hollow cathode lamps
 Electrodeless discharge lamps
AAnalyst 600
Highly Versatile Furnace Autosampler
 User Benefits:






Automatic generation
of reference solutions
Automatic multiple
injections
Automatic dilution
Automatic injection
into a preheated tube
Variable pipetting
speed
Ease-of-operation
AAnalyst 600
Revolutionary Optical System
 Real time double beam system
 High sensitivity segmented solid-state photodiode
detector
•
User Benefits:
 Exceptional analytical performance
 Highest Long-term Stability
AAnalyst 600
Customized Solid-State Detector

Highest quantum efficiency

Integrated low noise CMOS
charge amplifier array

Exceptional signal-to-noise ratio
AAnalyst 600
Quantum Efficiency of Detectors
solid state detector
photomultiplier
AAnalyst 600
Furnace (THGA) Instrument Detection Limits
THGA Instrument detection limits (IDL) / pg
Element
PMT
Photodiode
As
9
6
Cr
1.5
0.4
Cu
5
4
Mn
2
1.5
Pb
3
3
Tl
7.5
7
AAnalyst 600
Automatic Lamp Selector

8-Lamp holder

Built-in power
supplies for hollow
cathode and
electrodeless
discharge lamps

Automatic
alignment, element,
wavelength and slit
selection
AAnalyst 600
Unique Overall Conception
 Total system control via AA WinLab32 software for
highest versatility and simplest operating
convenience
•
•
•
•
Atomizer control
Lamp and lamp current control
THGA control
Accessory control
AAnalyst 600
Unique Software Conception
 Automatic system setup from stored user’s methods
•
•
Direct from Workspace
 Method
 Sample information
 Individual screen design, window selection etc.
User Benefits:
 Analytical reliability
 Ease-of-operation
 Time-saving
WinLab32 for AA
Bringing a new level of productivity to high-performance AA
AA WinLab32 - Features and Benefits
 Improve productivity
•
•
•
•
•
•
•
Data Reprocessing *
WinLab32 Offline *
Priority samples *
Append to Analysis List *
Edit Calibration
Recall Calibration
Furnace Method Development wizard *
 Improve ease of use and reduce training
•
•
•
•
Tool tips (available in 6 languages) *
Wizards *
Analysis List *
AS-93 parameters integrated *
* New features not present in 16-bit AA WinLab
AA WinLab32 - Features and Benefits
 Reduce training and support
• Common look and feel with WinLab32 for ICP-OES
• CD Document Pack
 Improve stability and data accessibility
• Access database *
 Method and data security
•
•
•
•
Password protection *
Multiple user levels *
Data check sums to detect changes *
21 CFR Part 11 Compliant
* New features not present in 16-bit AA WinLab
WinLab32 for AA Workspace
Toolbar
Status
Monitor
Automated
Analysis
Results
Calibration
Common look and feel with WinLab32 for ICP for easy cross platform training
Data Reprocessing
 Recalculation of analytical data
• Correct SIF errors
• Change calibration function
• Delete replicate(s)





Performed using the raw data
Samples can be reprocessed in any sequence
Original data are preserved
Analytical log can be printed
Reprocessed data are identified
Data Reprocessing
Status display
Select samples in the
order you want them
reprocessed.
Change sample information
in these columns
Furnace Method Development Wizard
Define Furnace
Steps to cycle
Temperatures
Analyze Solutions
and Display Results
Align Autosampler Tip Wizard
Auto dilution by system
Priority Sample
Samples can be added without
interrupting current analyses
Exporting Data to LABWORKS
WinLab32 Enhanced Security Option
 Enhancement to WinLab32 for AA (and ICP)
 Significant set of new features
• Audit trails
• File versioning
 Enable compliance with new regulations
• 21 CFR Part 11 - Pharmaceutical
• 40 CFR Part 3 - Environmental (proposed)
• Others
 Primarily for highly regulated laboratories
•
•
•
•
Users actions are restricted
Increased storage space requirements
Additional information entry requirements
Requires more system housekeeping
AAnalyst 600
Total Range Graphite Furnace AA
 THGA-type furnace with Zeeman-effect background
correction
 User Benefits:
Selection of the best system for individual
requirements and budgets
 High performance, near interference-free trace
analysis with STPF concept

AAnalyst 600
Integrated THGA Furnace System
AAnalyst 600
Zeeman THGA Furnace
 Transversely heated graphite furnace
 Longitudinal Zeeman effect background correction
User Benefits:
Exceptional detection limits
 Minimized interferences and memory effects
 Best possible background correction
 Mimimum sample preparation time
 Shorter analysis time (fast furnace programs)

AAnalyst 600
Integrated THGA System

THGA Concept: more
than 2500 systems in
use

Longitudinal ZeemanEffect: highly resolved
background
compensation without
light loss

DC furnace power
supply

Closest approach
to the "ideal system"
AAnalyst 600
Integrated THGA System
0.125
Atomic and
background signals
for Ba, 20uL, 25 ug/L
Ab so rb an ce
0.100
0.075
A A -B G
0.050
BG
0.025
0.000
0
1
2
3
4
T im e / s
5
6
7
8
AAnalyst 600
Zeeman versus D2 Background Correction




Background correction independent of wavelength

Char. mass typically 10 and 20 % poorer than with D2 (the
m0 for the worst case, Cu, is 50% poorer)

Zeeman-effect background correction gives superior
detection limits in real samples
True double-beam with only one optical path
Baseline noise at least 2x lower
Optical resolution Dl is 100x better
AAnalyst 600
Highly Versatile Furnace Autosampler
 High-capacity, interchangeable sample trays
 88 or 146 sample positions
 Full AA WinLab32 control including multi-tasking
 User Benefits:
Automatic generation of reference solutions
 Automatic multiple injections
 Automatic dilution
 Automatic injection into a preheated tube
 Variable pipetting speed
 Ease-of-operation

AAnalyst 600
Flow Injection - Furnace Coupling
 Optional accessory for coupling FI-MHS with furnace
AA
 Software controlled automatic operation
User Benefits:
 Detection limits in range of ng/L
 Time-savings by automatic on-line operation
 Less interferences since matrix components are
removed in the FI system
AAnalyst 600
Automatic Slurry Sampling
 Optional ultrasonic probe integrated in the
autosampler
 Automatic introduction of solid samples as slurries
 Full software control
User Benefits:
 Reduced sample preparation and analysis time
 Reduced potential for contamination
 Easy operation
What else can PerkinElmer offer?
 Sample Preparation Solutions
• Multiwave 3000
• High Pressure Asher (HPA)
 Flow Injection Technology (FIAS)
• For sample pre-treatment
• Hydride generation
 Stand-alone Mercury systems (FIMS)
 Sample Introduction Systems
• Autodilutors
• Laser Ablation systems
 World class service and support
Inorganic sample preparation….
 Multiwave 3000
•
•
•
•
•
Reduced digestion times
Superior digestion quality
Time-saving
Easy operation
Maximum safety
 High Pressure Asher
• Complete sample
mineralization
• Minimum organic residue
• No elemental losses
• No contamination
Multiwave 3000
HPA system
…a clear solution for sample preparation !
FIAS – Flow Injection Systems
 2 Models
• FIAS 100 (1 valve, 1 pump)
• FIAS 400 (1 valve, 2 pumps)
 Automated sampling for
Flame AA
•
•
•
•
Dilution
Add reagents or modifiers
Matrix removal
Preconcentration
FIAS 100 system
 Improved sample handling
• Small sample volumes
• High solids samples
 Hydride generation
• Determination of As, Se, Te,
Be, Sb, Sn
FIAS 400 system
Flow Injection Mercury Systems
 FIMS 400
• Determines Mercury via
Cold Vapor AA (CVAA)
• Small footprint
• Fully automated
• Easy to operate
• Stand alone system
• Cost effective
• Now with WinLab32 for AA
software
AAnalyst 600
Conclusions
 Not just another AA!
 No compromises!
 Easiest, simplest AA furnace
 Full automation
 Full range of accessories
 Power of AA WinLab32 software
 Ultimate in performance
 The AA instrument to take you beyond 2000...
Download