Mohsen Farvardin M.D.
• Improved patient comfort
•
Better ergonomic handling
• Faster procedures
Fast swiveling motion & variable swiveling angles (30 ° or 45 ° )
Adjustable headrest (height)
Left/right eye detection, automated movement from OD OS and central position
3
®
Reproducibility (standard deviation microkeratome >20µm)
Single use patient interface
Very homogeneous flap thickness minimal deviation in geometries (diameter, hinge, etc.)
Even stromal bed
Wide adjustment range of geometries and parameters
Non-mechanical Keratoplasty and intrastromal Rings
Bladeless
Better results (no astigmatism & abberation induction)
5
Flap creation using Femto-Laser
• Cutting geometries are designed on the computer and created with LASER precision
– Flap diameter very accurate
– Large applanation area
– Large effective ablation area for the Excimer
– Hinge and orientation not depending to the suction ring and its application
– Lamellar cut through out the flap (homogeneous thickness)
– Surgeon can design and control (computer aided) side cut angle, flap thickness, diameter and centration
– Visibility to the stroma through out the cutting procedure
– Flap is after femto-LASER application not separated from the stroma
– Custom Flap design
6
7
-Flaps
-Standard Flaps (round)
-Custom Flaps (oval)
-Rings
-Keratoplasty
-Penetrating Keratoplasty
- Anterior Lamellar Keratoplasty
-Posterior Lamellar Keratoplasty
8
12
New Features
• Build in online pachymeter (OLCR- Optical Low-Coherence Reflectometry)
– Static and dynamic (during ablation) measurement of corneal thickness
– Can be saved by soft button
– Needs proper apex adjustment (distanced diodes) Traffic light system
19
New Features
• Build in N
2 generator
– Continuously purged beam-path; enhancing energy stability
– simplifying logistics and operation, reducing running cost and space requirements
– Just one gas bottle ArF
20
New Features
Enhanced beam-path and laser head design
• The combination of a short beam-path and continuously (while switched on) N
2 purged optics (starting at the Laser head to the scanner output) grants for stability and efficient use of energy, while keeping the optics free of dust and ozone formation.
• New Laser head design multiplying expected life time
21
New Features
Advanced motorized Zoom
Microscope
• Stepless zoom
• Programmable magnifications for:
• Treatment
• Start
• Prepare
22
•To move illumination ring to treatment /prepare position
•Switches between / combines:
•Microscope - field Illumination
•OP – field Illumination
•Plume evacuator
•Starts before Laser treatment
•Increased working distance 250 mm
•Infrared light illumination
•NOTE: Energy sensor moves automatically (not visible) into the beam path for Energy Check
23
24
- the solid Base
Wavelight EX500 uses the well known
Wavefront Optimized profiles
25
- the solid Base
WaveLight:
Wavefront Optimized TM optical zone
Non-wavefront optimized optical zone
Wavefront Optimized TM treatments result in a large true aspheric optical zone and a functional transition zone . This results in better mesopic and scotopic vision.
Non-wavefront optimized treatments create relatively narrow optical zone a wide transition zone. These profiles may cause night vision issues caused by induced higher order aberrations.
26
– Visual Outcomes
Effectiveness: UCVA (Uncorrected visual acuity)
100%
80%
64%
93%
99%
100%
76%
93%
99%
100%
60%
40%
20%
0%
25%
22% wavefront-guided Wavefront Optimized TM
>= 20/12.5
>= 20/16
>= 20/20
>= 20/40
>= 20/200
Both groups demonstrated similar performance for visual acuity. In both groups 93% of patients achieved UCVA 20/20 or better after treatment.
Source: US Clinical Trials 200 Hz ALLEGRETTO WAVE
®
27
Active Cyclotorsion Control :
Never change a running system!
•
The advanced NeuroTrack feature ensures active opto-kinetic eye-tracking to control cyclotorsion .
• NeuroTrack forces the eye to stabilize the retinal image to achieve perfect vertical and horizontal orientation.
28
• Results from two international sites of 141 high astigmatism corrections.
The post-operative plot diagram shows the high accuracy of treatment results.
29
Video-based eye-tracker guarantees fast multidimensional active eye-tracking for better results and outmost patient care.
• High speed tracking 1050 Hz
• Ultra fast - 2.5 ms latency
• Multi-dimensional eye-tracking
• Requires no dilation; allows streamlined workflow
• Works in infra-red light
• Three independent angulated lightsources for redundant lightning
• Compensation option for angle kappa
30
When patient is looking up and down the head isn ’ t moving, but the eye is rolling!
Available at NEXT revision of Wavelight EX500
31
Displacement calculated by conventional
Eye-Tracker
+ x
Centre of ablation using rotational compensation for X and Y rotation
Detected centre of pupil horizontal displacements vertical displacements rotational centre of the eye
~13 mm below the cornea
Available at NEXT revision of Wavelight EX500
1 st dimension:
2 nd dimension:
3 rd dimension:
4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation
32
Roots of Rotation errors:
Patient check up is carried out in sitting position, but treatment in supine arrangement
Patient might sit in a angled head-position to the examination tool
Rotation caused by patient “ squeezing ” against the speculum during ablation or flap creation vertical displacements
Static cyclotorsion compensation for errors resulting from sitting to supine position or head position
Practicable for T-CAT with Topolyzer Vario horizontal displacements
Dynamic cyclotorsion compensation resulting from torsion movements during the treatment
Available at NEXT revision of Wavelight EX500
1 st dimension:
2 nd dimension:
3 rd dimension:
4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation
5 th dimension: cyclotorsion
33
vertical displacements horizontal displacements passive tracking for large displacement in Z axis
(laser stops triggering) and visual control (distance diodes)
Available at NEXT revision of Wavelight EX500
1 st dimension:
2 nd dimension:
3 rd dimension:
4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation
5 th dimension: cyclotorsion
6 th dimension: Z displacement
34
Pupil centroid shift caused by natural shift of pupil centre at a different pupil diameter
(example: wavefront measured at scotopic pupil, while treatment is performed in mesopic to photopic condition)
Pupil centroid change during ablation, caused by change of illumination or accommodation.
Mesopic
1 st dimension:
2 nd dimension:
3 rd dimension:
4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation
5 th dimension: cyclotorsion
6 th dimention: Z displacment
7 th dimension Centroid shift
Scotopic
Static and dynamic centroid shift compensation for all errors resulting from pupil size changes
Practicable with T-CAT and Topolyzer Vario
35
• Corneal vertex centering
– Obligatory for Topography Guided
– Pre-selectable for WFO and Custom Q
• Pupil Centre centering for different lighting conditions (photopic, mesopic or scotopic)
– Pre-selectable for WFO and Custom Q
• Line of sight centering
– Obligatory for Wavefront Guided ablation
– Pre-selectable for WFO and Custom Q
36
Surgeon view:
Laser and eye tracker
Compensated OPMI 300µm
OPMI = Surgeons view superior inferior
37
38
Eye-tracker
Energy stability
Energy calibration
Eye alignment
Cyclotorsion
Pulse control
Thermal impact
1050 Hz, 2.5 ms and multidimensional active video based eye-tracker tracks pupils from 1.0 up to 8.0 mm
Steady and reliable energy stability throughout the treatment due to the closed loop energy control and the enhanced sealed beam path
WaveLight ® EX500 now includes N
2 purging of laser head optics!
Automatic energy calibration before every patient
Convenient fluence test on PMMA once a day
Integrated and advanced Eye Tracker alignment & cross line projector with the WaveLight
®
EX500 passive cyclotorsional alignment
Every laser pulse is controlled from its source till the point where it is applied to the cornea
no uncontrolled ablation possible with
Minimized thermal impact because by thermo neutral pulse distribution
Every 5th pulse is allowed to overlap
39