IN THE NAME OF GOD

New femtolasik

Refractive suite

Mohsen Farvardin M.D.

Swiveling bed

• Improved patient comfort

Better ergonomic handling

• Faster procedures

Fast swiveling motion & variable swiveling angles (30 ° or 45 ° )

Adjustable headrest (height)

Left/right eye detection, automated movement from OD  OS and central position

3

WaveLight

®

FS200

Why femtosecond LASER?

Safety

Reproducibility (standard deviation microkeratome >20µm)

Single use patient interface

Precision

Very homogeneous flap thickness minimal deviation in geometries (diameter, hinge, etc.)

Even stromal bed

Versatility

Wide adjustment range of geometries and parameters

Non-mechanical Keratoplasty and intrastromal Rings

Patient benefit

Bladeless

Better results (no astigmatism & abberation induction)

5

Advantages Femto vs. mechanical microkeratome

Flap creation using Femto-Laser

• Cutting geometries are designed on the computer and created with LASER precision

– Flap diameter very accurate

– Large applanation area

– Large effective ablation area for the Excimer

– Hinge and orientation not depending to the suction ring and its application

– Lamellar cut through out the flap (homogeneous thickness)

– Surgeon can design and control (computer aided) side cut angle, flap thickness, diameter and centration

– Visibility to the stroma through out the cutting procedure

– Flap is after femto-LASER application not separated from the stroma

– Custom Flap design

6

Lamellar flap created by the FS200

7

Versatility

-Flaps

-Standard Flaps (round)

-Custom Flaps (oval)

-Rings

-Keratoplasty

-Penetrating Keratoplasty

- Anterior Lamellar Keratoplasty

-Posterior Lamellar Keratoplasty

8

Wavelight EX500

12

New Features

• Build in online pachymeter (OLCR- Optical Low-Coherence Reflectometry)

– Static and dynamic (during ablation) measurement of corneal thickness

– Can be saved by soft button

– Needs proper apex adjustment (distanced diodes) Traffic light system

19

New Features

• Build in N

2 generator

– Continuously purged beam-path; enhancing energy stability

– simplifying logistics and operation, reducing running cost and space requirements

– Just one gas bottle  ArF

20

New Features

Enhanced beam-path and laser head design

• The combination of a short beam-path and continuously (while switched on) N

2 purged optics (starting at the Laser head to the scanner output) grants for stability and efficient use of energy, while keeping the optics free of dust and ozone formation.

• New Laser head design multiplying expected life time

21

New Features

Advanced motorized Zoom

Microscope

• Stepless zoom

• Programmable magnifications for:

• Treatment

• Start

• Prepare

22

Illumination Ring

•To move illumination ring to treatment /prepare position

•Switches between / combines:

•Microscope - field Illumination

•OP – field Illumination

•Plume evacuator

•Starts before Laser treatment

•Increased working distance  250 mm

•Infrared light illumination

•NOTE: Energy sensor moves automatically (not visible) into the beam path for Energy Check

23

Allegretto ’ s proven features

24

Wavefront Optimized

- the solid Base

Wavelight EX500 uses the well known

Wavefront Optimized profiles

25

Wavefront Optimized

- the solid Base

WaveLight:

Wavefront Optimized TM optical zone

Non-wavefront optimized optical zone

Wavefront Optimized TM treatments result in a large true aspheric optical zone and a functional transition zone . This results in better mesopic and scotopic vision.

Non-wavefront optimized treatments create relatively narrow optical zone a wide transition zone. These profiles may cause night vision issues caused by induced higher order aberrations.

26

Wavefront Optimized

– Visual Outcomes

Effectiveness: UCVA (Uncorrected visual acuity)

100%

80%

64%

93%

99%

100%

76%

93%

99%

100%

60%

40%

20%

0%

25%

22% wavefront-guided Wavefront Optimized TM

>= 20/12.5

>= 20/16

>= 20/20

>= 20/40

>= 20/200

Both groups demonstrated similar performance for visual acuity. In both groups 93% of patients achieved UCVA 20/20 or better after treatment.

Source: US Clinical Trials 200 Hz ALLEGRETTO WAVE

®

27

NeuroTrack - preventing torsion

Active Cyclotorsion Control :

 Never change a running system!

The advanced NeuroTrack feature ensures active opto-kinetic eye-tracking to control cyclotorsion .

• NeuroTrack forces the eye to stabilize the retinal image to achieve perfect vertical and horizontal orientation.

28

NeuroTrack - Cross Line Projector

• Results from two international sites of 141 high astigmatism corrections.

The post-operative plot diagram shows the high accuracy of treatment results.

29

All encompassing eye-tracking

Video-based eye-tracker guarantees fast multidimensional active eye-tracking for better results and outmost patient care.

• High speed tracking 1050 Hz

• Ultra fast - 2.5 ms latency

• Multi-dimensional eye-tracking

• Requires no dilation; allows streamlined workflow

• Works in infra-red light

• Three independent angulated lightsources for redundant lightning

• Compensation option for angle kappa

30

Why multidimensional ET?

When patient is looking up and down the head isn ’ t moving, but the eye is rolling!

Available at NEXT revision of Wavelight EX500

31

Compensating for H and V rotation

Displacement calculated by conventional

Eye-Tracker

+ x

Centre of ablation using rotational compensation for X and Y rotation

Detected centre of pupil horizontal displacements vertical displacements rotational centre of the eye

~13 mm below the cornea

Available at NEXT revision of Wavelight EX500

1 st dimension:

2 nd dimension:

3 rd dimension:

4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation

32

Cyclotorsion the 5th dimension

Roots of Rotation errors:

Patient check up is carried out in sitting position, but treatment in supine arrangement

Patient might sit in a angled head-position to the examination tool

Rotation caused by patient “ squeezing ” against the speculum during ablation or flap creation vertical displacements

Static cyclotorsion compensation for errors resulting from sitting to supine position or head position

Practicable for T-CAT with Topolyzer Vario horizontal displacements

Dynamic cyclotorsion compensation resulting from torsion movements during the treatment

Available at NEXT revision of Wavelight EX500

1 st dimension:

2 nd dimension:

3 rd dimension:

4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation

5 th dimension: cyclotorsion

33

Z displacement the 6th dimension

vertical displacements horizontal displacements passive tracking for large displacement in Z axis

(laser stops triggering) and visual control (distance diodes)

Available at NEXT revision of Wavelight EX500

1 st dimension:

2 nd dimension:

3 rd dimension:

4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation

5 th dimension: cyclotorsion

6 th dimension: Z displacement

34

Pupil centroid shift

Pupil centroid shift caused by natural shift of pupil centre at a different pupil diameter

(example: wavefront measured at scotopic pupil, while treatment is performed in mesopic to photopic condition)

Pupil centroid change during ablation, caused by change of illumination or accommodation.

Mesopic

1 st dimension:

2 nd dimension:

3 rd dimension:

4 th dimension: horizontal displacements vertical displacements horizontal rotation vertical rotation

5 th dimension: cyclotorsion

6 th dimention: Z displacment

7 th dimension Centroid shift

Scotopic

Static and dynamic centroid shift compensation for all errors resulting from pupil size changes

Practicable with T-CAT and Topolyzer Vario

35

Automated Centering

Automated, surgeon and predefined centering option

• Corneal vertex centering

– Obligatory for Topography Guided

– Pre-selectable for WFO and Custom Q

• Pupil Centre centering for different lighting conditions (photopic, mesopic or scotopic)

– Pre-selectable for WFO and Custom Q

• Line of sight centering

– Obligatory for Wavefront Guided ablation

– Pre-selectable for WFO and Custom Q

36

Parallax Compensation

Surgeon view:

Laser and eye tracker

Compensated OPMI 300µm

OPMI = Surgeons view superior inferior

37

Card Concept

38

Safety

Eye-tracker

Energy stability

Energy calibration

Eye alignment

Cyclotorsion

Pulse control

Thermal impact

1050 Hz, 2.5 ms and multidimensional active video based eye-tracker  tracks pupils from 1.0 up to 8.0 mm

Steady and reliable energy stability throughout the treatment due to the closed loop energy control and the enhanced sealed beam path

 WaveLight ® EX500 now includes N

2 purging of laser head optics!

Automatic energy calibration before every patient

Convenient fluence test on PMMA once a day

Integrated and advanced Eye Tracker alignment & cross line projector with the WaveLight

®

EX500 passive cyclotorsional alignment

Every laser pulse is controlled from its source till the point where it is applied to the cornea

 no uncontrolled ablation possible with

Minimized thermal impact because by thermo neutral pulse distribution

 Every 5th pulse is allowed to overlap

39