AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS ► History ► Scope ► Objectives and covered risks ► Safety general principles ► Terminology ► The circuits ► Grade of Insulation ► Quantification of insulation ► Heating ► Resistance to fire ► Fault conditions ► Television receivers ► Philosophy of CEI 62368-1 AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS IEC 60065:1952 (ed 1.0) 1952 Safety requirements for electric mains operated radio receiving apparatus IEC 60065:1965 (ed 2.0) Safety requirements for mains operated electronic and 1965 related equipment for domestic and similar general use IEC 60065:1998 (ed 6.0) 07Audio, video and similar electronic 1998 apparatus – Safety requirements 091998 ACOS = Advisory Committee On Safety IEC 60950:1986 (ed 1.0) Safety of information technology equipment including electrical business equipment IEC 60950:1991 (ed 2.0) + A1:1992 + A2:1993 + A3:1995 + A4:1996 GUIDE IEC 112:1998 (ed 1.0) by ACOS Guide on the safety of multimedia equipment 1986 1996 IEC 60065:2001 (ed 7.0) 2001 Audio, video and similar electronic apparatus – Safety requirements TC92 IEC 60950-1:2001 (ed 3) Information technology equipment – Safety – Part 1: General requirements TC 74 Evolution of apparatus functionalities High density of electronic components ==> Increase and mixing of functionalities TC 108 2005 2010 2013 = (TC92 + TC 74) IEC 60065:2001 +A1:2005 TC108 IEC 60950-1:2005 TC108 CEI 62368-1 :2010 TC108 AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Electronics apparatus for » reception, generation, recording » Record and reproduction of audio, video and associated signals » Combination of the above apparatus Household and similar general use Places of public assembly » School, theatres, » Workplace Supplied by: » » » » Mains External power supply module Battery Remote power feeding At a rated voltage of » 250 V (single phase) or » 433 V (other than single phase) May be connected to telecommunication network or Cable distribution network of antenna signal Sound and /or image receiver and amplifier (radio, television set, Citizen Band radio etc..); Supply apparatus intended to supply other apparatus in this standard scope; Audio and/or video educational apparatus (record player, tape reader, tape walkman and video player, etc..); Multimedia apparatus; Beamer; Video recorder and associated monitors (camera, camcorder, etc..) ; Electronic gaming and scoring machines; Juke boxes; Electronic light effect apparatus; cable head-end receivers; Antenna signal converters and amplifiers; Antenna positioners; Alarm systems apparatus; Record and optical disc players; Professional sound/video systems; Electronic flash apparatus for photographic purposes; Etc… Film, slide and overhead projectors » IEC 60335-2-56 gaming and scoring machines for commercial use » IEC 60335-2-82 AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Standard requirements allow A protection against: Hazardous current through human body (electrical choc) Excessive temperature value Fire ignition and propagation Mechanical instability Injury from mechanical parts Hazardous radiations Implosion and explosion effects Design of a reliable apparatus Current flow through human body Observed physiological effects depend on: » Intensity of the current Applied voltage and frequency Body impedance (contact surface, humidity) » Duration of the passage » Current path in the body High intensity : directs effects » » Burning Ventricular fibrillation Low intensity : involuntary reaction » » » Downfall Injury Etc.… Direct contact in normal condition » Parts at hazardous voltage Insulation failure; in fault condition » » Rupture of the electric envelope Contact current Short-circuit between high current energy source connectors » » » Arcing Emission of molten metal Burning Possible risks with low voltage circuits » Battery Excessive heating » » In normal use In single fault situation • Overload, • Insulation failure Ignition, fire » » Releasing of connection Inflammation of liquid Instability » » On inclined plane In full deployment situation Sharp edges and corners Moving parts Projection of particles » » Implosion of cathode ray tube (CRT) Explosion of battery Radiations Lasers and LED Sound frequencies Radio frequencies AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Safety integration Remove or lower the risk at the design phase Protect for risks which cannot be removed at the design phase Inform the user about the residual risks Marking/Training Goal: cancel all risk during the foreseeable life time of the apparatus : transportation, installation, usage, shutdown and disposal Avoid risks in normal operation conditions but also: In fault condition In foreseeable unexpected usage Under external environmental influences (temperature, humidity, altitude, pollution, overvoltage etc…) Choose material and components in such a way that they can: Operate without being hazard source, during the apparatus life time Be compatible with the other components Operate correctly in their ratings Avoid hazard in single fault condition Identify type of circuits in the apparatus (Primary, Secondary, Low voltage, Extra-low voltage, Safety Extra low voltage, current limited , Telecommunication network voltage, cable distribution of antenna signal). Determine insulation between: - circuits taken by pairs, - each circuit and accessible part (basic, supplementary, double, reinforced) Verify conformity to standard requirements (creepage distance, clearance, solid insulation, dielectric strength ) AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Mains » power source with voltage > 35 V (peak) a.c. or d.c. Rated voltage; rated current consumption; rated power consumption; rated frequency; » Values in normal operating condition » Expected to be marked on the apparatus » As an alternative, rated current consumption and rated power consumption may be given in the instruction manual. » “/” for user selectable ratings (120/240 V) » “-” for rating range (120-240 V) Tolerance = +10%, -10% Class I » Basic insulation + earth connection of conductive accessible parts Class II » Double insulation or reinforced insulation Class III: Not defined in IEC 60065 Defined in IEC 60950-1 and CEI 62368-1 » Apparatus supplied by a SELV circuit or Energy Source class 1 (ES1) and » No internal hazardous voltage or Energy Source class 3 (ES3) Direct connection to the mains Mains fuse ≥9A Apparatus Conductive connection to the mains Mains 2000 Ω ≥ 0,7 mA Apparatus Permanently connected apparatus » Needs a tool » Cannot be loosened by hand Remote power feeding » supply of power to apparatus via a cable network (e.g.: Telecommunication) Pluggable equipment Type A » connection to a mains supply via a non-industrial plug and socket-outlet or a non-industrial appliance coupler, or both Pluggable equipment Type B » connection to a mains supply via a industrial plug and socket-outlet or an appliance coupler, or both, complying with IEC 60309 Protective earthing terminal » TERMINAL to which parts are connected and which is required to be connected to earth for safety reasons Enclosure » housing affording the type and degree of protection suitable for the intended application Safeguard against the spread of fire from inside to outside of the product Safeguard against mechanically-caused injury Safeguard against electrically-caused injury Minimize the spread of fire or flames from within Reduce the risk of injury due to mechanical and other physical hazards Limit access to parts that may be at hazardous voltage or Hazardous energy level Mechanical enclosure Electrical enclosure Fire enclosure The enclosure may be only for one protection The same enclosure can provide all the three protections. Decorative enclosure » Is outside the mechanical enclosure of the apparatus » Has no safeguard function Noise signal » random signal having normal probability distribution of instantaneous values. Pink noise » Energy per unit bandwidth inverse, proportional to frequency Rated load impedance » Output circuit load specified by the manufacturer (4 Ω, 2x8 Ω, 32 Ω etc..) Source transducer » Convert the energy of a non electrical signal to electrical energy Load transducer » convert the energy of an electrical signal into another form of energy Non-clipped output power » 1000 Hz sine-wave power dissipated at the onset of clipping on either one, or both peaks. Pollution degree 1 » No pollution or dry pollution, non-conductive, Pollution degree 2 » Normal, non-conductive, possibility of temporary conductivity due to condensation Pollution degree 3 » Conductive pollution area, or non-conductive pollution which could become conductive due » to expected condensation AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Primary Secondary Hazardous live voltage Hazardous energy Low Voltage Extra Low Voltage Safety Extra Low Voltage Limited current Telecommunication network Cable distribution network Primary circuit: conductively connected to the mains; may content the following components: » » » » » » » » Cables Primary winding of transformer Filters components (mainly for EMC reasons) Motors Relay Fan Fuse Etc.… Secondary circuit: not conductively connected to the mains » » Separated from primary circuit Supplied by isolation means: transformer, converter etc… Hazardous live voltage » » » > 35 V peak or 60 V d.c. > 120 V rms for professional audio apparatus signal > 71 V rms. for non professional audio apparatus signal Hazardous energy » » Stored charge > 45 µC for charging voltage U: 60 V < U ≤ 15kV peak or d.c. For charging voltage U > 15 kV peak or d.c., then discharged energy > 350 mJ Extra Low Voltage (ELV) » » ≤ 35 V peak or ≤ 60 V d.c. in normal condition Hazardous voltage in single fault condition Safety Extra Low Voltage (SELV) » ≤ 35 V peak or ≤ 60 V d.c. in normal condition » ≤ 70 V peak or ≤ 120 V d.c. in single fault condition » Separated from hazardous voltage by 3 methods • • • M1: double insulation or reinforced insulation M2: basic insulation with screen connected to the earth M3: basic insulation with secondary circuit connected to the earth » Separated from TNV2 and TNV3 circuit by basic insulation Current limited circuits: by construction, the current never become dangerous, regardless the voltage level. » IEC 60065: current (using measuring network), between any part of the circuit and accessible part (Touch Current) » IEC 60950-1: current (measured through non inductive 2000 Ohms load or using measuring network) between: any two parts of the circuit, any part of the circuit and earth any part of the circuit and accessible part Current limited circuits: measuring network Current limits and measured values in normal conditions 0,7 mA peak for sinusoidal or mixed signals U2 = 0,35 V peak a.c. 2 mA d.c. U1 = 1 V d.c. 70 mA peak for frequency >100kHz U1 = 35 V peak a.c. ! Under tropical climate, current limits are multiplied by 2 Current limited circuits measuring network Current limits and measured values under single fault 2,8 mA peak for sinusoidal or mixed signals U2 = 1,4 V peak a.c. 8 mA d.c. U1 = 4 V d.c. 140 mA peak for frequency >100kHz U1 = 70 V peak a.c. Leakage current: equivalent to « Touch Current » in the protective earthing connection Telecommunication network » Metallic wire ended transmission means for communication between two apparatus » May be submitted to atmospheric overvoltage Telecommunication Network Voltage circuit (TNV) » » » » Located inside the apparatus Not conductively connected to the mains Has limited accessible surface Voltage level limited in normal and in single fault conditions » 4 types: TNV0, TNV1, TNV2 et TNV3 TNV0 and TNV1 limits same SELV SELV < (TNV2 and or TNV3) < TNV limits TNV limits Summary table for TNV circuits TNV-3 TNV-3 PABX TNV-1 Analogic interface TNV-2 TNV-0 PABX digital AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Insulation » Conceptual separation between two circuits or between a circuit and an accessible part. » Basic, supplementary, double or reinforced (electrical choc protection). » Functional Special case of functional insulation » Not provides protection against electrical choc » Can be used to lower ignition risk (between SELV and protective Earth) » Can be used for EMC reasons (Electro-Magnetic Compatibility ) Insulation Level of protection F B S D R E (earth) 0 1 1 2 2 1 Suitable protection against electrical choc = Basic + Supplementary = Basic + Earth connection = Double = Reinforced PRINCIPLE: always 2 levels of protection Example Metallic enclosure connected to earth B ou S Primary Mains connection F D B TNV SELV R Hazardous voltage B Outlet S/R SELV Telecommunication lines Current limited B Data output connector: RS232... Exercise (To find circuit type and insulation grade) 1000 V d.c; mA 85 V 120 V a.c. Connection to the mains Metallic enclosure + 18 V 1 +5V AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Creepage distance (CR) » Shortest distance between two conductive parts, measured on the surface of the insulating material Clearance (CL) » Shortest distance between two conductive parts, measured in the air See Annex E of IEC 60065:2011 for all possible situations Distance through the isolation » Thickness of solid insulation Insulation resistance » Measurement on any insulation type Dielectric strength » » » » On any insulation type On thin sheet materials May be required in addition to CR and CL. On any insulation as validation test after environmental treatment (heating, cooling, humidity, vibration, choc etc…) Creepage distance Tables 8, 9, 10 et 12 » Supply voltage » Pollution degree » Grade of insulation » Working voltage » Overvoltage category » Material group and comparative tracking index Clearance: Tables 11 et 12 » Supply voltage » Pollution degree » Grade of insulation » Overvoltage category » Working voltage Distance through insulation: §8.8 » Grade of insulation Insulation resistance: Table 5 » Grade of insulation Dielectric strength: Table 5 » Supply voltage » Working voltage » Grade of insulation Working voltage: Maximum voltage value between 2 circuits separated by an insulation (expressed in rms, peak or d.c.) » Value including non-periodic superimposed pulses with a half-value time longer than 50 ns » Unearthed accessible conductive parts shall be assumed to be connected to an earth terminal » Floating circuit assumed to be connected to an earth terminal at the point which results in the highest working voltage being obtained; » Double insulation: short-circuit across on of the insulation when measuring the second one and vice versa. Working voltage: » Between two transformer windings: TS = highest voltage between any two ends of the windings » Between transformer winding and other parts of the apparatus: TS = highest voltage between any end of the winding and the other part Overvoltage category: Define the level of overvoltage on the mains according to 4 identified areas IV: Outdoor power lines and cables III: Building installation II: Equipments, apparatus IV III II I I: parts of apparatus connected to secondary circuit Table from IEC 60950-1 Material group: characterisation of resistance against spread of arching on insulation material surface » CTI = Comparative Tracking Index » 4 groups I II IIIa IIIb 600 400 175 100 ≤ ≤ ≤ ≤ CTI CTI < 600 CTI< 400 CTI < 175 » If CTI not known, group IIIb is used. Thin sheet material : no insulation thickness required if: » Basic and supplementary insulation 2 layers of sheet material, each withstand the dielectric strength test 3 layers of sheet material with any 2 by 2 combination withstand the dielectric strength test » Reinforced insulation 2 layers of sheet material withstand the dielectric strength test 3 layers of sheet material with any 2 by 2 combination withstand the dielectric strength test Thin sheet material : Dielectric strength test instrument Printed board » CR and CL between 2 conductors, one may be conductively connected to the mains : Figure 10 d lacquer = ignored d » type B coated printed board (type 2) shall comply with the requirements of IEC 60664-3 Jointed insulation » Uncemented joints: normal CR et CL » Cemented joints : no CR et CL; but 3 samples submitted to 10 times the following thermal cycling test • • • • 68 h at (X ± 2)°C 1 h at (25 ± 2)°C 2 h at (0 ± 2)°C 1 h at (25 ± 2)°C X= (Max temperature max during heating test + 10K), with minimum 85°C 1 sample submitted to dielectric strength with test level x 1,6 and after humidity treatment 2 samples submitted to dielectric strength with test level x 1,6 without humidity treatment No insulation breakdown Enclosed and sealed parts (§13.7) »Not directly connected to the mains »CR and CL in Table 12 3 samples submitted to 10 times thermal cycling test • 68 h at (X ± 2)°C • 1 h at (25 ± 2)°C • 2 h at (0 ± 2)°C • 1 h at (25 ± 2)°C X= (Max temperature max during heating test + 10K), with minimum 85°C Dielectric strength test No failure allowed. Enclosed, filled and sealed parts (§13.8) Insulating compound fills all internal void spaces » No CR and CL; but » 3 samples submitted to 10 times thermal cycling test as above. » Dielectric strength test » After test, visual verification: no cracks in the encapsulating, impregnating or other material, coatings not loosened or shrunk no significant voids in the material after sectioning the component Insulation resistance » Measured with 500 V d.c. Dielectric strength » Direct current voltage or alternative current voltage at mains frequency » The measurement equipment shall be able to source 200mA when its output is short-circuited » Internal overcurrent limited to 100 mA during test » Application of half of the maximum test voltage, increase quickly the voltage level to the maximum value and maintain it for 1 minute. AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Test conditions » Maximum load configuration » Apparatus positioned in accordance with the » » » » instructions for use If position not specified, 5 cm behind the front edge of an open-fronted wooden test box with 1 cm free space along the sides and top and 5 cm depth behind the apparatus Apparatus supplied at maximum ranges of rated supply voltages with tolerance values added Measurement after thermal stability (in general after 4 hours of operating) Test environment air shall be quiet and not ventilated Measurement method » By thermocouples (refer to IECEE document reference CTL-OP 108) » By resistor variation Motor Transformer Inductance Not used for switching mode power supply transformer Permissible temperature rise: tableau 3 Maximum values in single fault condition Permissible value can be exceeded in the following situations: » Short-circuit of insulation which withstand dielectric strength test » Short-circuit or disconnection of a component in conformity of requirements of the standard clause 14 Maximum values in single fault condition Permissible value can be exceeded in the following situation: » operation of replaceable or resettable protective devices °C Heating test 2 min Permissible Temperature rise t Heating test Heating test t Heating test 1 min Measurement of dielectric strength Maximum values in single fault condition Permissible values can be exceeded: » on printed circuit board: by 100K for 5min » for class V-0 printed circuit board on one or more small surfaces with total value no more than 2 mm2 in case of no electrical choc. Conductors can be interrupted, peeled or loosened during the test providing that: » The printed board is classified V-0 » The interruption is not a potential fire source » CL and Cr are not reduced » Protective earthing connection is maintained AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Objective: Prevent » Ignition (Potential ignition source : V > 50 V d.c. or peak and P > 15 VA) » Spread of fire Solutions » Good design practice in order to prevent potential ignition sources Thermal cut-out Electronic circuit for protection (IC current limiter) » Choice of appropriate components Flammability categories as per IEC 60695-11-10 Their position in the apparatus » Implementation of fire enclosure Flammability categories » From HB, outer decorative part, to 5V metallic enclosure » Wood and wood-based material of thickness > 6 mm === V-1 HB V-2 V-1 V-0 5V No Flammability class required Ventilation opening < 1 mm Envelop > V-0 - components Metallic parts < 4g Small electrical components Printed board V-1 Capacitors volume < 1750 mm3 AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Implementation conditions » Apparatus in normal working situation » Only one single fault each time » Multiple faults can result from the applied single fault » Possibility of non operation of the apparatus after the fault test Which fault to simulate? » Open and short-circuit » Overload of the output of linear or switch mode power supply transformer » Continuous dissipation of apparatus designed for noncontinuous dissipation » Excessive dissipation of integrated circuit » Isolation breakdown between primary circuit and any accessible parts: conductive accessible parts earthed metallic screen SELV Limited current circuit Which fault to simulate? » Unexpected impedance value loaded on power output » » » » » terminal Short-circuit of protection components (thermostats, temperature limiter) or of component bridging these protections if the apparatus is used without surveillance Opening of component in regulation circuit loop Overload of motors (blocked rotor) neutralisation des timers simulation of cooling liquid leakage Evaluation during fault conditions » No excessive heating » No hazardous voltage or energy on accessible parts » No loosening of protective earth connection » Moving parts shall not become dangerous » In case of ignition, no spread of fire outside of the enclosure (flame shall stop in less than 10 s) AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS Surge test (§10.1) » Between : TERMINALS for the connection of antenna AND MAINS supply TERMINALS » Between MAINS supply TERMINALS AND any other TERMINAL of apparatus providing supply to antenna apparatus » 50 discharges at a maximum rate of 12/min, from a capacitor of 1 nF charged to 10 kV (tested apparatus is not supplied) » Expected result: dielectric strength test OK Surge test (§10.1) Test circuit Surge test (§10.1) Example of switch S Antenna coaxial sockets (§12.5) » 3 tests in the following order: Endurance: 100 insertion and withdrawal Impact: 3 spring-operated hammer impact of 0,5 J Torque: 10 times 50 N force applied during 10 s » Followed by a dielectric strength test » No damage in the sense of this standard: No access to hazardous voltage No damage to any isolation Antenna coaxial sockets Test plug for endurance test and its dimensions Mechanical strength of picture tubes(§18) » Protective film required if maximum face dimension > 16 cm » Intrinsically protected tubes: IEC 61965 tested » No Intrinsically protected tubes : implosion test Scratch on the side or on the face of the tube Repeatedly cooling with liquid nitrogen (-273°C + 77 K = -196 °C) up to fracture » Expected result: No particle exceeding 2 g shall have passed a 25 cm high barrier, placed 50 cm from the tube No particle, regardless its size, shall have passed a similar barrier at 2 m. Mechanical strength of glass (§19.5) » Excluded: picture tubes; laminated glass with surface area > 0,1 m2 or major dimension > 450 mm » Test: 3 shocks of 0,5 J using impact hammer » If the glass breaks or cracks: fragmentation test §19.5.1 » Expected result: number of particles counted in a square of 50 mm > 45 or no loose of particles in the square (particles are kept together) AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS PRINCIPLE 1- Pain, injury or property damage occurs during transfer of energy from an energy source to a body part or to property 2- Safety = interposition of safeguard in order to reduce the likelihood of the transfer of the energy and/or the hazard level Energy source Energy transfer Three block model for pain and injury Body part Three blocks model for safety Energy source Safeguard Body Models for protection against fire Energy source Safeguard Energy source Fuel material Fuel material Safeguard Equipment safeguard » » » » basic supplementary double reinforced Installation safeguard » supplementary • • Specified by the manufacturer Implementation not controlled by the manufacturer Personal safeguard » » » basic supplementary reinforced Instructional safeguards » » » basic supplementary reinforced Precautionary safeguard » » for class 2 Energy Source provided by skilled person to instructed person • • • training experiences supervision Skilled safeguards » » » for class 2 and class 3 Energy Source supplementary related to skilled person Identify and classify the Energy Source for each type of hazard (SE1, SE2, SE3). Require the appropriate Protection for each Energy Source (basic, supplementary, double , reinforced) Verify conformity to standard requirement AFSEC Certification Officer 26/27-08-2013 NAIROBI Jean LANZO IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS