Next Generation CAT System Non-scanning CT (computerized tomography) CT(computerized tomography) creates 3D views of what is inside General medical imaging technique to look inside of a patient’ body Standard CT system Background Motivation CT machines take much time(15~20min) and real-time operation is a challenging issue. A huge system has been required for scanning mechanism since the first invention. The first inventor of CT, Hounsfield (Nobel Prize winner, 1979) Hounsfield’s sketch CT Development History No scan th Compact Safe 5 ? 14stth 2:ndLinear spiral 3:rdMultiple : Fan-beam CT & rotational orscanning helical CT CT CT CT Concept for Non-scanning CT Concept of future wearable CT machines A sketch of a next generation CT for next Nobel Prize Comparison between current and conceptual CTs State-of-the-art CT (Aquilion ONE ) Toshiba Medical System, 2006 Conceptual diagram of ascan-free CT For real-time 3D reconstruction Related Technique Shield Field Imaging (Douglas Lanman, Ramesh Raskar et al. [2008] ) Shadow-based 3D reconstruction by a single shot image Limitation : impossibility to local concave and backside shapes A single shot image Shield Field system 3D Reconstruction Decoupling to multi-view images Related Technique Tomographic Reconstruction of Transparent Objects ( Borislav Trifonov et al. [2006] ) 3D reconstruction of a transparent object by tomography using 72~360 captured images Limitation : Requirement of moving system and many captured images Capturing System A glass object One of 360 images Reconstruction Result Experimental System 6~16 LEDs and a translucent object are used here. Canon EOS 450D (12M pixels) Schematic diagram of system 150x100 pinhole array (pinhole diameter of 428 microns) Actual system Non-scanning CT based on light field capturing 3D Reconstruction of transparent objects using visible light with a single shot photo Limitation : 3D reconstruction in low resolution because decoupled multiview images are in low resolution, 80x80 A single shot photo Single shot CT for a translucent object 3D shape Reconstruction Decoupling to multi-view images Decoupling Process A Single shot LF image Decoupled multi-view images Decoding process of a coded 4D light field image Background Elimination Elimination of background Reference Images 3D Reconstruction by ART Volume Reconstruction by ART (Algebraic Reconstruction Technique) 5 multi-view Images Experimental Results Multi-view images(resolution is 100x200) 3D reconstruction results