Principle/Testing of IEC 60598-1/IEC 60598-2-1 Vicky Zhang Product Expert DEKRA Shanghai IECEE Workshop August 26 & 27 Nairobi - Kenya IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS t226 & 27, Nairobi - Kenya Content • Why? • What? • How? t326 & 27, Nairobi - Kenya • Why to use IEC standards? t426 & 27, Nairobi - Kenya t526 & 27, Nairobi - Kenya Recalls by product categories - 2012, EU t626 & 27, Nairobi - Kenya Recalls by type of risk - 2012, EU t726 & 27, Nairobi - Kenya Product Risks t826 & 27, Nairobi - Kenya What is product safety? No hazards to environment No hazards to People Product Safety No hazards to other equipments t926 & 27, Nairobi - Kenya Provisions against Hazards Electrical Hazards B Mechanical hazards A Heat related C hazards Provisions Radiation hazards E D Fire hazards t10 26 & 27, Nairobi - Kenya Advantage of IEC standards Representing market needs Transparent process IEC Standards Wide adoption Bases of national standard or regulations Reducing risk, increasing quality, confidence t11 26 & 27, Nairobi - Kenya Technical committees SC 34A Lamps SC 34B Lampcaps/ holders TC 34 Lamps and related equipments SC 34D Luminaires SC 34C Auxiliaries for lamps t12 26 & 27, Nairobi - Kenya • What criterias are required in IEC 60598-1/60598-2-1? t13 26 & 27, Nairobi - Kenya Standards • IEC 60598-1 Luminaires – Part 1: General requirements and tests t14 26 & 27, Nairobi - Kenya Standards • IEC 60598-2-1 Luminaires – Part 2- Particular requirements for Fixed general purpose luminaires t15 26 & 27, Nairobi - Kenya Scope • Fixed general purpose luminaire • Working voltage <= 1000 V • Tungsten filament, tubular fluorescent and other discharge lamps t16 26 & 27, Nairobi - Kenya Definition – Fixed luminaire • Not easily be moved from one place to another • A: only be removed with the aid of a tool or • B: for use out of arms reach t17 26 & 27, Nairobi - Kenya Classification • Protection against electrical shock • Class I luminaire: basic insulation + protective earthing • Class II luminaire: basic + supplementary insulation or reinforced insulation • Class III luminaire: SELV (safety extra-low voltage) t18 26 & 27, Nairobi - Kenya Conformity Assessment Type Test Routine Test Carried out by laboratory To use standardized test method To check compliance of the design of a product Carried out by manufacturers after production To ensure every luminaire conforms with the sample approved under type test t19 26 & 27, Nairobi - Kenya Conformity Assessment Type Test Routine Test Carried out by laboratory To use standardized test method To check compliance of the design of a product Carried out by manufacturers after production To ensure every luminaire conforms with the sample approved under type test t20 26 & 27, Nairobi - Kenya Component • Suitable for use in the Luminaire • Correct Classification and Ratings • In compliance with relevant IEC requirements To ensure safety of usage t21 26 & 27, Nairobi - Kenya Provision of Marking • Marking on products • Mounting Instructions The height of letters and numerals ≥ 2 mm . The height of symbol ≥ 5 mm • Durability and legiability t22 26 & 27, Nairobi - Kenya Construction - Lampholder • Positioning test t23 26 & 27, Nairobi - Kenya Construction - Lampholder • Bending test t24 26 & 27, Nairobi - Kenya Construction - Lampholder • Torque test t25 26 & 27, Nairobi - Kenya Construction – Terminal block • Space - Luminaire with connecting leads requires a terminal block to connect to fixed wiring - Adequate space for terminal block t26 26 & 27, Nairobi - Kenya Construction – Reliable terminals • 8 mm conductor • live conductor • earth conductor t27 26 & 27, Nairobi - Kenya Construction – Reliable terminals • External cable & Internal wiring • Retained by cord anchorage • Clamped by spring terminal t28 26 & 27, Nairobi - Kenya Construction – Reliable terminals • Internal wiring - Anchored to a tag before soldering - Twisted in a reliable manner - Fasten by sleeve, tape - Inserted into a hole of PCB, bend and soldered t29 26 & 27, Nairobi - Kenya Construction – Reliable terminals • Internal wiring - Securely crimped - Securely wrapped t30 26 & 27, Nairobi - Kenya Construction – Double/Reinforced Insulation • Metal encased class II luminaire - No contact between mounting surface and part with basic insulation only Double insulated wire Terminal block with a cover t31 26 & 27, Nairobi - Kenya Construction – Double/Reinforced Insulation • Metal encased class II luminaire - No contact between accessible part and basic insulation → Double insulated wire → Insulating lining, sleeve Mechanical strength 1.Retained by positive means 2.Not be removed without being seriously damaged Electrical strength Thermal strength 1. Humidity 48 hrs 1. Thermal test 2. Insulation resistance & electric strength 2. T(wire)+20°C 3. Aging T(wire)+20°C, 240 hrs, checked by electrical strength t32 26 & 27, Nairobi - Kenya Construction – Screws • Torque test No damage No creep t33 26 & 27, Nairobi - Kenya Construction – Screws • Torque test • 0,5 Nm for screws on cord anchorage bearing directly on cable or cord t34 26 & 27, Nairobi - Kenya Construction – Glands • Torque test t35 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Impact test t36 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Impact test - Live part shall not be accessible - Insulation shall not be impaired - No reduction on IP protection and classification - Removable/replaceable part can be removed/replaced without breakage t37 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Metal part enclosing live part - Pressure test by test finger 30 N Metal part shall not touch live part No reduction on creepage distance and clearance t38 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • All Suspended luminaires - Loading test 4 x weight of luminaire 1 hrs No deformation on suspension system t39 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Rigid Suspended luminaires - Torque test 2,5 Nm, 1 min Clockwise and anti-clockwise No rotation more than one revolution in both directions t40 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Rigid Suspension bracket (heavy duty) - Loading 40 N, >=2,5 Nm, at free end - 1 min - No permanent displacement, deformation t41 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Rigid Suspension bracket (light duty) - Loading 10 N, >=1,0 Nm, at free end - 1 min - No permanent displacement, deformation t42 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Track mounted luminaire - Luminaire mass < max. load for track t43 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Adjusting device - No twisting over 360 t44 26 & 27, Nairobi - Kenya Construction – Mechanical Strength • Flexing test - Strands broken < 50% - Insulation resistance & electric strength t45 26 & 27, Nairobi - Kenya Construction – Flammable Material • Glow-wire test 650 C • Spacing 30 mm • No fiercely burning material t46 26 & 27, Nairobi - Kenya External Wiring • Supply connection Supply cable & Plug Adaptor for track Terminals t47 26 & 27, Nairobi - Kenya External Wiring • Supply connection Connecting leads Appliance inlet t48 26 & 27, Nairobi - Kenya External Wiring • Type of cable • 0,75 mm2 for ordinary luminaires; • 1,0 mm2 for other luminaires t49 26 & 27, Nairobi - Kenya External Wiring • Type of connection - Type X attachment - Type Y attachment - Type Z attachment t50 26 & 27, Nairobi - Kenya External Wiring • Cord anchorage t51 26 & 27, Nairobi - Kenya External Wiring • Cord anchorage - Pull test (25 time, displacement <= 2mm) - Torque test t52 26 & 27, Nairobi - Kenya Internal Wiring • Internal wiring directly connected to fixed wiring Operating current >= 2 A Operating current < 2 A min. 0,5 mm2 min. 0,4 mm2 Insulation thickness: min. 0,6 mm (PVC or Rubber) 1,5 mm2 for through wiring Insulation thickness: min. 0,5 mm (PVC or Rubber) -- t53 26 & 27, Nairobi - Kenya Internal Wiring • Internal wiring connected to fixed wiring via current limiting device <= 2 A If current-carrying capacity and the mechanical properties are adequate - Cross-sectional area min. may be less than 0,4 mm2 - Insulation thickness may be less than 0,5 mm t54 26 & 27, Nairobi - Kenya External & Internal Wiring • Soldering Clamping terminal Spring terminal t55 26 & 27, Nairobi - Kenya External & Internal Wiring • Soldering Spring terminal Cold flow Bad electrical connection Clamping terminal t56 26 & 27, Nairobi - Kenya Earthing • Accessible metal part, basic insulated • Non-accessible metal part, basic insulated, but in contact with supporting surface - Reliably connected to earthing terminal or earthing contact t57 26 & 27, Nairobi - Kenya Earthing t58 26 & 27, Nairobi - Kenya Earthing • Location of earthing terminal • Adjacent to mains terminal (type X, Y) • Material of earthing terminal • Brass or non-rusting material • Bare contact surface t59 26 & 27, Nairobi - Kenya Earthing • Cord for earthing • Green-yellow cord shall only be used for earthing connection • Earthing make contact first • Earthing detached later t60 26 & 27, Nairobi - Kenya Earthing • Terminal blocks with integrated screwless earthing contacts t61 26 & 27, Nairobi - Kenya Earthing • Terminal blocks with integrated screwless earthing contacts • Pull test 20 N – terminal block shall be in place • Pull test 50 N – applies only to earthing contact – no damage, no loosen on earthing contact • Earthing contact – supporting plate < 0,05 ohm t62 26 & 27, Nairobi - Kenya Earthing • Terminal blocks with integrated screwless earthing contacts • Voltage drop test • Resistance < 0,05 ohm t63 26 & 27, Nairobi - Kenya Protection against electrical shock • Live parts not accessible when luminaire installed and wired as in normal use or during lamp/starter replacement - Wall-mounted luminaires: within arm reach, no access to basic insulated parts by means of a Ø 50 mm probe t64 26 & 27, Nairobi - Kenya Protection against electrical shock • Basis insulated parts of Class II luminaires to be regarded as live parts t65 26 & 27, Nairobi - Kenya Protection against electrical shock • No basic insulated components on outside of luminaire • Luminaires incorporating a capacitor >0,5μF must be provided with a discharge device t66 26 & 27, Nairobi - Kenya Resistance to dust and moisture • Dust Test (IP#X) t67 26 & 27, Nairobi - Kenya Resistance to dust and moisture • Dust Test (IP#X) • Solid-objectproof (IP2X) • Solid-objectproof (IP3X or IP4X) • Dust-proof (IP5X) • Dust-tight proof (IP6X) t68 26 & 27, Nairobi - Kenya Resistance to dust and moisture • IP Test (IPX#) • Drip-proof (IPX1) • Drip-proof (IPX2) t69 26 & 27, Nairobi - Kenya Resistance to dust and moisture • IP Test (IPX#) • Rain-proof (IPX3) and splash-proof (IPX4) t70 26 & 27, Nairobi - Kenya Resistance to dust and moisture • IP Test (IPX#) • Jet-proof (IPX5) and powerful water jet-proof (IPX6) IP X5 15 min / distance = 3 m / 12,5 l/min ± 5 % (30 kN/m2) IP X6 3 min / distance = 3 m / 100 l/min ± 5 % (100 kN/m2) t71 26 & 27, Nairobi - Kenya Resistance to dust and moisture • IP Test (IPX#) • Watertight (IPX7) • 30 min in water / 150 mm of water above the top of the speciment and the lowest portion is subjected to at least 1 m head of water • Pressure watertight (IPX8) • 30 min in water / water pressure 1,3 x pressure which corresponds to the rated maximum immersion depth t72 26 & 27, Nairobi - Kenya Resistance to dust and moisture • Humidity test • R.H. 91% to 95 % • 10 ºC – 30 ºC • 48 hrs t73 26 & 27, Nairobi - Kenya Insulation Resistance • Class I luminaire: 2 Mohm • Class II luminaire: • Basic/Supplementary insulation: 2 Mohm • Double/Reinforced insulation: 4 Mohm • Class III luminaire: 1 Mohm t74 26 & 27, Nairobi - Kenya Electric Strength • Class I luminaire: 2U + 1000 V • Class II luminaire: • Basic/Supplementary insulation: 2U + 1000 V • Double/Reinforced insulation: 4U + 2000 V • Class III luminaire: 500 V t75 26 & 27, Nairobi - Kenya Creepage distance & Clearances • • • • Live Parts of different polarity Live Parts Adjacent Metal Parts Live Parts Body or Housing Live Parts Mounting Surface t76 26 & 27, Nairobi - Kenya Creepage distance & Clearances t77 26 & 27, Nairobi - Kenya Endurance and Thermal test • • • • Endurance 7 or 10 Days Thermal Test Normal operation Thermal Test Abnormal operation Thermal Test on luminaires classified for mounting on normally flammable surfaces • Thermal Test on thermalplastic luminaires t78 26 & 27, Nairobi - Kenya Resistance to heat, fire and tracking • Ball Pressure Test • Needle Flame Test t79 26 & 27, Nairobi - Kenya Resistance to heat, fire and tracking • Glow-wire Test 650 ºC • Tracking Test on IP>20 Luminaire t80 26 & 27, Nairobi - Kenya Conformity Assessment Type Test Routine Test Carried out by laboratory Use standardized test method To check compliance of the design of a product Carried out by manufacturers after production To ensure every luminaire conforms with the sample approved under type test t81 26 & 27, Nairobi - Kenya Routine test by Manufacturer • Visual check • Function test • Earth continuity (earthing resistance: 0,05ohm) • Electric strength or insulation resistance (for metal encased) • Polarity (for Class I luminaire) t82 26 & 27, Nairobi - Kenya • How to build up a laboratory carrying out testing of IEC 60598-2-1? t83 26 & 27, Nairobi - Kenya What is a laboratory? • Area where tests are conducted (electrical, chemical, physical, mechanical etc.) Why are tests conducted in a laboratory? • External influences on the test results are ruled out! • Conditions for testing are controlled! t84 26 & 27, Nairobi - Kenya Conditions which can influence test results in your laboratory? Manpower Machines Human factors Environmental conditions Equipment Methods Test methods/validation Measurement traceability Sampling Handling of test items Means Consumable goods/ items t85 26 & 27, Nairobi - Kenya Process model Manpower Input Machines Output Process Means Methods t86 26 & 27, Nairobi - Kenya Manpower Machines Manpower Input • • • • Output Process Competent staff Staff in training (adequate supervision needed) Personnel competent and qualified Goals and policy / procedures for training and qualification requirements • Job descriptions (management, technical and supporting) • Records of all personnel maintained, readily available (authorizations, competences, qualifications, training, skills, experience…) Means Methods t87 26 & 27, Nairobi - Kenya Manpower Machines (1) Input Machines Output Process Means Methods • Facilitate correct performance of tests • Technical requirements that can effect the results documented • Monitor, control, record environmental conditions and stop testing when environmental conditions jeopardize results • Effective separation of incompatible areas • Access and use shall be defined and controlled t88 26 & 27, Nairobi - Kenya Manpower Machines (2) Input Machines Output Process Means Methods • Lab with all equipments required for the correct performance of tests • Equipment capable of achieving accuracy needed • Authorized personnel; up to date instructions • Unique identification • List of records for each piece of equipment t89 26 & 27, Nairobi - Kenya Manpower Machines (3) Input Machines Output Process Means Methods • IECEE – CTL testing equipments under CB scheme http://www.iecee.org/ctl/equipment/html/ctl_testing_lite.htm • IECEE-CTL Operational Procedures CTL-OP 108 Use of thermocouples CTL-OP 109 Acceptance of thermocouples CTL-OP 110 Procedure for measuring power source characteristic CTL-OP 111 Traceability of calibrations and calibration intervals • http://www.iecee.org/ctl/operational/Operational_procedures.htm t90 26 & 27, Nairobi - Kenya Manpower Machines (4) Input Machines Output Process Means Methods • Refer to CTL-OP 110 “Procedure for Measuring Laboratory Power Source Characteristics” 8.1 When not otherwise specified in the testing standard, the power source used for testing shall meet the following requirements: A. Voltage stability: ± 3 % maximum B. Frequency stability: ± 2 % maximum C. Total harmonic distortion (THD): maximum 5 % t91 26 & 27, Nairobi - Kenya Manpower Machines (5) Input Machines Output Process Means Methods • Note: IEC 60598-1, cl. 12.4.1 e) ±1% (preferred ± 0.5%) voltage stability instead of ± 3%! t92 26 & 27, Nairobi - Kenya Manpower Machines (6) Input Machines Output Process Means Methods t93 26 & 27, Nairobi - Kenya Manpower Machines (7) Input Machines Output Process Means Methods t94 26 & 27, Nairobi - Kenya Manpower Machines (8) Input Machines Output Process Means Methods t95 26 & 27, Nairobi - Kenya Manpower Machines (9) Input Machines Output Process Means Methods t96 26 & 27, Nairobi - Kenya Manpower Methods Input Output Process Means • • • • Machines Methods Appropriate methods for all tests within scope Instructions for all equipment Up to date and readily available to personnel Methods must meet the requirements of standards • Latest valid editions of standards to be used t97 26 & 27, Nairobi - Kenya Manpower Means Input Machines Output Process Means Methods • Policy and procedures for selection & purchase of services and supplies, when relevant for tests • Procedures for inspecting supplies prior to use • Purchasing documents reviewed and approved for technical content prior to release t98 26 & 27, Nairobi - Kenya Manpower Input Input Machines Output Process Means Methods • Review of requests, tenders and contracts • • • • • Methods adequately defined Posses capability and resources Differences resolved before work begins Record of reviews maintained, including discussion with clients Any subcontracted work t99 26 & 27, Nairobi - Kenya Manpower Output Input Machines Output Process Means Methods • Reporting results • Shall include all information requested by the client and all information required by the method used • Subcontracted results clearly identified t100 26 & 27, Nairobi - Kenya Manpower Output Input Machines Output Process Means Methods • IECEE – TRF (test report form) http://members.iecee.org/ • IECEE – TRF guide • OD-2020 • http://www.iecee.org/Operational_documents/odcb_index.html Vicky Zhang Product Expert DEKRA Shanghai IECEE Workshop August 26 & 27 Nairobi - Kenya IEC SYSTEM OF CONFORMITY ASSESSMENT SCHEMES FOR ELECTROTECHNICAL EQUIPMENT AND COMPONENTS