indoor air quality and energy saving TECHNICAL DATA CONTROL CTR08-PH EVO(D)-PH REVERSUS 1 EVO(D)-PH + sonda CO2/VOC/U.R. CLASS CTR08-PH EVO(D)-PH REVERSUS 2 EVO(D)-PH + sonda CO2/VOC/U.R. B A A UNIT CONTROL EVO(D)-PH REVERSUS 1 ENTALPICO EVO(D)-PH + sonda CO2 /VOC/U.R. CLASS UNIT EVO(D)-PH REVERSUS 2 ENTALPICO EVO(D)-PH + sonda CO /VOC/U.R. 2 A A A A A B A+ A B C D E F G A REVERSUS/ REVERSUS ENT HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS REVERSUS Residential ventilator unit with dual flow and high yield heat recovery. The EVO-PH control has a coloured, backlit touch screen interface with intuitive viewing of the working status of the machine. It enables precise adjustment of ventilator speed and has a weekly , time schedule for automatic management of the ventilators. It can be controlled by an external switch to activate the booster function, it can automatically adjust the air flow rate if connected to an air quality probe, it can manage any air post treatment accessories, it automatically manages the bypass and prevents heat exchanger freezing by managing the speed of the ventilators or, if installed, an electrical pre-heating resistor (optional accessory outside the machine); it signals to the user the need to replace the filters (the clogging status of the filters is monitored by a pair of different pressure switches, supplied as standard) or an anomaly, indicating the origin. With the addition of optional accessories (COP kit and CAV kit installed on the channel) you can manage the ventilation machine in constant pressure or constant flow rate mode. PERFORMANCE Equipped with a counter current heat exchanger in thermoplastic material (polystyrene) and electronic backward blade ventilators. The total bypass as standard allows favourable climatic conditions to be taken advantage of outside the building for free cooling (or free heating) in automatic mode. STRUCTURE REVERSUS is manufactured using a self-supporting structure in 23 mm thick sandwich panels, insulated in polyurethane foam. The external t part of the structure is manufactured in plastofilmed sheet metal in grey, while the internal part is in Aluzinc, material that ensures high resistance against corrosion. Inside, REVERSUS is in expanded polypropylene, material that ensures a high level of thermal insulation between air flows. The access to filters (F7 for the renewed air flow and G4 for the extraction air flow) is particularly easy thanks to the two specific openings on the front panel. REVERSUS, is also available in enthalpy version. Is prepared for installation inside buildings with an ambient temperature between 0°C and 45°C. It can be installed on a wall with connections for renewal air and expulsion on the upper part; for connections to supply and extraction ducts, you can choose to use the connections available on the top or bottom of REVERSUS (or both). The EVOD-PH-IP control has the same characteristics as the EVO-PH version with the addition of Modbus communication protocol which allows full control of the machine by the supervision software of the home automation system. The implemented webserver allows interaction with the machine, even with an internet browser of a device connected (even from remote) to the home automation system in which the machine is inserted. For a more complete view of the characteristics of the control panels, please read the specific manuals CONTROLS REVERUSUS was supplied with an electric box and control system; it is available in a version equipped with EVO-PH control and a version equipped with EVOD-PH-IP control prepared for complete integration in home automation systems (Modbus protocol with Ethernet connection or, on request, with the addition of connection RS485). The new version of our control systems enables extremely easy and rapid passage from a control system to another, even after installation with the single replacement of the remote panel. 2 PERFORMANCES (UNI EN 13141-7) The unit must be ducted properly: UTEK authorizes the use only according to its performance diagram shown into this catalogue The claimed performances are guaranteed only by UTEK original filter low pressure loss REVERSUS 1 Pressure Nominale Ref Serie1 Max Min Min Serie6 Max Power Serie8 Ref Min P Min 0,000 700 0,020 0,040 0,060 0,080 0,100 200 180 600 160 500 Power [W] Pressure [Pa] Air flow (m3/s)[m3/s] Portata 140 120 400 100 300 80 60 200 40 100 20 0 0 0 50 100 150 200 250 300 350 400 Air flow (m3/h)[m3/h] Portata REVERSUS 2 Power Pressure Max MaxSerie5 RefReference Min Serie2 Max Max P Ref Serie8 Min 0,100 0,120 Serie4 Air flow (m3/s) Portata d'aria [m3/s] 0,020 0,040 0,060 0,080 400 700 350 600 300 500 250 400 200 300 150 200 100 100 50 0 0 0 50 100 150 200 250 300 Air flow (m3/h) Portata d'aria [m3/h] 3 350 400 450 500 Power [W] Pressure [Pa] 0,000 800 PERFORMANCES (UNI EN 13141-7) The unit must be ducted properly: UTEK authorizes the use only according to its performance diagram shown into this catalogue The claimed performances are guaranteed only by UTEK original filter low pressure loss REVERSUS ENTHALPIC 1 Pressure Serie1 Max Serie5 Ref Min Min Serie6 Max Power Serie8 Ref Min P Min 0,000 700 0,020 0,040 0,060 0,080 0,100 200 180 600 160 500 Power [W] Pressure [Pa] Air flow [m³/s] Portata [m3/s] 140 120 400 100 300 80 60 200 40 100 20 0 0 0 50 100 150 200 250 300 350 400 Air flow [m³/h]3/h] REVERSUS ENTHALPIC 2 Power Pressure Max Max Serie5 Ref Min Min MaxMax P Nominale Ref Min MinP Air flow [m³/s] 0,020 0,040 0,060 0,080 0,100 0,120 400 700 350 600 300 500 250 400 200 300 150 200 100 100 50 0 0 0 50 100 150 200 250 Air flow [m³/h] 4 300 350 400 450 500 Power [W] Pressure [Pa] 0,000 800 HEAT RECOVERY PERFORMANCE (sensible efficiency) Values refered to the following conditions(UNI EN 13141-7): Tbs external air 5°C; U.R. esternal 72%; Tbs enviorment 20°C; U.R. enviorment 28% REVERSUS REVERSUS ENTHALPIC Efficiency % Air flow [m³/s] 0,00 100 0,02 0,04 0,06 0,08 0,10 0,12 0,14 97 94 91 88 85 82 79 0 50 100 150 200 250 Air flow [m3/h] 5 300 350 400 450 500 TEST LEAKAGE REVERSUS 1/ENTHALPIC LEAKAGE CLASS OUTDOOR TEST CONDITIONS Positive pressure 250 Pa INDOOR Negative pressure 250 Pa INDOOR Pressure difference 100 Pa A1 A1 A1 TEST LEAKAGE REVERSUS 2/ENTHALPIC LEAKAGE CLASS OUTDOOR TEST CONDITIONS Positive pressure 250 Pa OUTDOOR Negative pressure 250 Pa INDOOR Pressure difference 100 Pa A2 A2 A2 NOISE LEVEL REVERSUS/REVERSUS ENTHALPIC Lw Sound power level taken in accordance to UNI EN ISO 3447 NOISE FROM THE CASE (dB) REVERSUS 1/ENTHALPIC Fans MAX 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz Lw dB(A) 65,6 64,0 55,3 50,1 4000 Hz 45,5 8000 Hz 59,6 49,4 63,7 REF 54,2 61,0 54,7 46,9 41,1 35,5 39,3 56,0 Fans 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Lw dB(A) MAX 52,6 66,2 63,8 56,1 53,5 53,1 63,7 66,5 REF 47,7 60,7 56,7 47,4 43,7 42,4 46,7 57,2 Fans MAX 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz Lw dB(A) 59,2 66,8 59,8 59,0 4000 Hz 49,1 8000 Hz 59,2 37,6 66,5 REF 51,3 59,4 56,9 51,9 50,5 39,5 28,1 58,5 Fans 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Lw dB(A) MAX 61,5 63,4 69,8 65,9 64,3 56,8 50,8 71,0 REF 54,1 60,1 60,8 57,1 56,4 48,3 42,1 62,8 REVERSUS 1/ENTHALPIC NOISE IN THE DUCTS (dB) NOISE FROM THE CASE (dB) REVERSUS 2/ENTHALPIC NOISE IN THE DUCTS (dB) REVERSUS 2/ENTHALPIC ELECTRICAL DATA FAN MATCHING Power Supply Current max. Insulation class UNIT REVERSUS/ENTHALPIC Supply Current max. REVERSUS 1/ENT 2 X 85W 230 V, 50/60 Hz 1F 2 X 0,75A IP 54 classe A 230 V, 50 Hz 1F 1,6 A REVERSUS 2/ENT 2 X 170W 230 V, 50/60 Hz 1F 2 X 1,65A IP 54 classe A 230 V, 50 Hz 1F 3,5 A 6 DIMENSIONS (mm) WEIGHT (kg) 105 130 Weight Reversus 1 : 43 kg Weight Reversus 2 : 45 kg Weight Reversus enthalpic 1 : 48,28 kg Weight Reversus enthalpic 2 : 50,28 kg 330 103 Ø150 500 718 12 Ø1/2"gas 767 288 103 360 130 103 INSTALLATION REVERSUS/ENTHALPIC WALL INSTALLATION 720 Minimum required space for maintenance (mm) 770 500 7 INSTALLATION REVERSUS/ENTHALPIC STANDARD SIPHON P Ø 26 185 95 ØP 32 VALUES ACCORDING REGULATION (UE) N. 1253/2014 MODEL REVERSUS 1 MAX AIR FLOW [m³/s] REF AIR FLOW [m³/s] REF PRESSURE [Pa] SPI [W/(m³/h)] LEAKAGE MAX CONTROL 0,091 0,063 50 0,294 4,0% (external) CTR08-PH 4,0% (internal) EVO(D)-PH REVERSUS 2 0,128 0,096 50 0,334 2,6% (external) CONTROL FACTOR SEC [kW h/(m².a)] 1 -73,7 (cold) (manual control) -35,7 (average) -11,3 (hot) 0,95 (clock control) -75,0 (cold) -36,8 (average) -12,3 (hot) EVO(D)-PH + probe CO2 /VOC/U.R. -77,4 (cold) 0,85 (central demand -38,8 (average) -14,1 (hot) control) CTR08-PH -69,6 (cold) 1 (manual control) -33,0 (average) -9,4 (hot) 2,6% (internal) EVO(D)-PH EVO(D)-PH + probe CO2 /VOC/U.R. 0,95 (clock control) -71,1 (cold) -34,3 (average) -10,5 (hot) 0,85 -74,0 (cold) (central demand -36,7 (average) control) -12,6 (hot) VALUES ACCORDING REGULATION (UE) N. 1253/2014 MODEL REVERSUS 1 ENTALPICO MAX AIR FLOW [m³/s] REF AIR FLOW [m³/s] REF PRESSURE [Pa] SPI [W/(m³/h)] LEAKAGE MAX CONTROL CONTROL FACTOR SEC [kW h/(m².a)] 0,096 0,067 50 0,309 3,7% (external) EVO(D)-PH 0,95 (clock control) -74,2 (cold) -36,2 (average) -11,8 (hot) 3,7% (internal) EVO(D)-PH + probe CO2 /VOC/U.R. REVERSUS 2 ENTALPICO 0,126 0,088 50 0,453 2,8% (esterno) EVO(D)-PH 2,8% (interno) EVO(D)-PH + probe CO2 /VOC/U.R. 7 -76,6 (cold) 0,85 (central demand -38,3 (average) -13,7 (hot) control) 0,95 (clock control) -67,7 (cold) -30,9 (average) -7,2 (hot) -71,3 (cold) 0,85 (central demand -33,9 (average) -9,9 (hot) control) Dear Customer Thanks for your attention to the product UTEK , designed and manufactured to ensure the real values to the User: Quality, Safety and Savings on working. UTEK S.r.l. UTEK reserves the right to at any time the necessary changes to improve products without prior notice . Made in italy the Dealer REVERSUS/REVERSUS ENTHALPIC_2016_1_EN HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS UTEK S.r.l. Via Provinciale,30 23030 Mazzo di Valtellina (So) Italy | Tel.+39 0342 862031 | Fax +39 0342 862029 | www.utek-air.it | utek@utek.it