<0> DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-11358 This is to certify that the Electric Power Cable with type designation(s) RFOU P1/P8, RFOU VFD with/without 3x distributed earth conductors, RFCU Manufactured by Draka Norsk Kabel - part of the Prysmian Group DRAMMEN, Norway is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC 60092-350 (2008-02) IEC 60092-353 (2011-08) IEC 60332-3-22 (2009-02) IEC 60754-1/2 (1994-01/1997-04) IEC61034-1/2 (2005-04/2005-04) NEK TS 606 (2009-05) (P-types only) Application General power & Lighting. Special types with enhanced insulation class for VFD applications. Flame retardant in bunch Cat. A. Halogen free. Low smoke. Type RFOU P1/P8 RFOU VFD with/without 3x distributed earth conductors RFCU Høvik, 2012-02-13 for Det Norske Veritas AS Marit Laumann Head of Section Voltage class (kV) 0,6/1 0,6/1 (1,8/3) 0,6/1 Temp. class (°C) 90 90 90 This Certificate is valid until 2016-06-30 DNV local office: Electrical Systems Ivar Bull Surveyor This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 1 of 5 Certificate No.: E-11358 File No.: 827.10 Job Id.: 262.1-002558-5 Product description Type: RFOU P1/P8 0,6/1 kV & RFOU-VFD 0,6/1 kV & RFCU 0,6/1 kV Construction: Conductors: Core insulation: Inner covering: Metal covering: Outer sheath: Tinned, stranded copper class 2 EPR Extruded flame retardant halogen free compound Tinned, Copper wire braid (O) or Galv. Steel wire braid (C) SHF2 mud resistant according to IEC 60092-350 Annex F & Annex G. RFOU P1/P8 0,6/1 kV Number of cores x conductor cross-section 2 mm 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 1 x 400 1 x 500 2 x 1,5/4 2 x 2,5/4 2 x 4/6 2 x 6/6 2 x 10/10 2 x 16/16 2 x 25/16 3 x 1,5/4 3 x 2,5/6 3 x 4/6 3 x 6/6 3 x 10/10 3 x 16/16 3 x 25/16 3 x 35/16 3 x 50/25 3 x 70/35 Overall diameter mm 13,0 ± 0,8 14,5 ± 0,8 16,0 ± 0,8 18,0 ± 0,8 20,5 ± 1,0 22,5 ± 1,0 25,0 ± 1,0 26,5 ± 1,0 29,0 ± 1,0 32,0 ± 1,5 35,5 ± 1,5 40,0 ± 2,0 43,5 ± 2,0 12,5 ± 0,8 13,5 ± 0,8 15,0 ± 0,8 16,0 ± 0,8 18,5 ± 0,8 21,0 ± 1,0 24,5 ± 1,0 13,0 ± 0,8 14,5 ± 0,8 15,5 ± 0,8 17,0 ± 0,8 19,0 ± 0,8 22,0 ± 1,0 26,0 ± 1,0 28,5 ± 1,0 33,5 ± 1,5 38,5 ± 1,5 Number of cores x conductor cross-section 2 mm 3 x 95/50 3 x 120/60 3 x 150/75 3 x 185/95 3 x 240/120 3 x 2,5 + E 3x4+E 3x6+E 3 x 10 + E 3 x 16 + E 3 x 25 + E 3 x 35 + E 3 x 50 + E 3 x 70 + E 3 x 95 + E 3 x 120 + E 3 x 150 + E 3 x 185 + E 3 x 240 + E 4 x 1,5/4 4 x 2,5/6 4 x 4/6 4 x 6/6 4 x 10/10 4 x 16/16 4 x 25/16 4 x 35/16 4 x 50/25 4 x 70/35 4 x 95/50 Overall diameter mm 43,0 ± 2,0 47,0 ± 2,0 53,5 ± 2,5 59,0 ± 2,5 67,0 ± 3,0 15,5 ± 0,8 17,0 ± 0,8 18,5 ± 0,8 21,0 ± 1,0 24,0 ± 1,0 28,5 ± 1,0 31,5 ± 1,5 36,5 ± 1,5 41,5 ± 2,0 47,0 ± 2,0 52,0 ± 2,5 57,0 ± 2,5 64,0 ± 3,0 71,5 ± 3,5 15,0 ± 0,8 16,0 ± 0,8 17,0 ± 0,8 18,5 ± 0,8 21,0 ± 1,0 24,5 ± 1,0 28,5 ± 1,0 31,5 ± 1,5 37,0 ± 1,5 42,5 ± 2,0 47,5 ± 2,0 Number of cores x conductor cross-section 2 mm 4 x 95/50 4 x 120/60 4 x 150/75 4 x 185/95 4 x 240/120 4 x 2,5 + E 4x4+E 4x6+E 4 x 10 + E 4 x 16 + E 4 x 25 + E 4 x 35 + E 4 x 50 + E 4 x 70 + E 5 x 1,5/6 5 x 2,5/6 7 x 1,5/6 7 x 2,5/6 12 x 1,5/10 12 x 2,5/10 19 x 1,5/10 19 x 2,5/10 27 x 1,5/10 27 x 2,5/16 37 x 1,5/16 37 x 2,5/16 Overall diameter mm 47,5 ± 2,0 52,5 ± 2,5 59,0 ± 2,5 65,5 ± 3,0 74,0 ± 3,5 17,0 ± 0,8 18,5 ± 0,8 20,0 ± 1,0 23,0 ± 1,0 26,0 ± 1,0 31,0 ± 1,5 35,0 ± 1,5 40,5 ± 2,0 45,5 ± 2,0 15,5 ± 0,8 17,0 ± 0,8 17,0 ± 0,8 18,0 ± 0,8 21,5 ± 1,0 23,5 ± 1,0 25,0 ± 1,0 27,0 ± 1,0 29,5 ± 1,0 32,0 ± 1,5 32,5 ± 1,5 36,0 ± 1,5 DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 2 of 5 Certificate No.: E-11358 File No.: 827.10 Job Id.: 262.1-002558-5 RFOU-VFD 0,6/1 kV (1,8/3kV) with 3x symmetrical distributed earth conductors Construction: Conductors: Earth conductors: Core insulation: Inner covering: Electrostatic screen: Metal covering: Outer sheath: Tinned, stranded copper class 2 or class 5 3x distributed earth conductors class 5 EPR Extruded flame retardant halogen free compound Cu/PETP-tape Tinned, Copper wire braid (O) SHF2 mud resistant according to IEC 60092-350 Annex F & Annex G. Number of cores x conductor cross-section 2 mm Overall diameter 3 x 10 + 3 x 4 3 x 25 + 3 x 6 3 x 50 + 3 x 10 3 x 95 + 3 x 16 3 x 120 + 3 x 25 3 x 150 + 3 x 35 29,0 ± 1,0 33,5 ± 1,5 41,5 ± 2,0 51,0 ± 2,5 57,0 ± 2,5 60,5 ± 3,0 mm RFOU-VFD 0,6/1 kV (1,8/3kV) with copper braid as earth conductor Construction: Conductors: Core insulation: Inner covering: Electrostatic screen: Metal covering: Outer sheath: Tinned, stranded copper class 2 or class 5 EPR Extruded flame retardant halogen free compound Cu/PETP-tape Tinned, Copper wire braid (O) SHF2 mud resistant according to IEC 60092-350 Annex F & Annex G. Number of cores x conductor cross-section mm2 Overall diameter 3 x 4 / 10 3 x 6 /10 3 x 10 / 10 3 x 16 / 16 3 x 25 / 16 3 x 70 / 35 3 x 95 / 50 21,5 ± 1 23,5 ± 1 25 ± 1 29 ± 1 33 ± 1,5 43 ± 2 49 ± 2 mm RFCU 0,6/1 kV Number of cores x conductor cross-section mm2 1 x 16 1 x 25 1 x 35 1 x 50 Overall diameter mm 13,0 ± 1,0 15,0 ± 1,0 16,5 ± 1,0 18,5 ± 1,0 Number of cores x conductor cross-section mm2 1 x 70 1 x 95 1 x 120 1 x 150 Overall diameter mm 21,5 ± 1,5 23,5 ± 1,5 25,0 ± 1,5 27,5 ± 1,5 Number of cores x conductor cross-section mm2 1 x 185 1 x 240 1 x 300 Overall diameter mm 29,5 ± 1,5 33,5 ± 2,0 36,5 ± 2,0 DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 3 of 5 Certificate No.: E-11358 File No.: 827.10 Job Id.: 262.1-002558-5 Number of cores x conductor cross-section mm2 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 3 x 1,5 3 x 2,5 3x4 3x6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 Overall diameter Number of cores x conductor cross-section mm2 mm 13,0 ± 1,0 14,0 ± 1,0 15,5 ± 1,0 17,0 ± 1,0 18,5 ± 1,0 21,5 ± 1,5 14,0 ± 1,0 15,0 ± 1,0 16,0 ± 1,0 17,5 ± 1,0 19,5 ± 1,0 23,0 ± 1,5 26,5 ± 1,5 29,5 ± 2,0 34,0 ± 2,0 40,0 ± 2,5 44,0 ± 2,5 Overall diameter mm Number of cores x conductor cross-section mm2 Overall diameter mm 3 x 120 48,5 ± 2,5 5 x 2,5 17,5 ± 1,0 3 x 150 + E 3 x 185 + E 3 x 240 + E 59,5 ± 3,0 65,0 ± 3,0 73,0 +/+3,0 7 x 1,5 7 x 2,5 17,5 ± 1,0 18,5 ± 1,0 4 x 1,5 4 x 2,5 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 15,0 ± 1,0 16,5 ± 1,0 17,5 ± 1,0 19,5 ± 1,0 21,5 ± 1,5 25,0 ± 1,5 29,0 ± 1,5 32,5 ± 2,0 38,0 ± 2,0 44,0 ± 2,5 48,5 ± 2,5 12 x 1,5 12 x 2,5 22,0 ± 1,5 24,0 ± 1,5 19 x 1,5 19 x 2,5 25,5 ± 1,5 27,5 ± 1,5 27 x 1,5 27 x 2,5 30,0 ± 2,0 32,5 ± 2,0 37 x 1,5 37 x 2,5 34,0 ± 2,0 37,5 ± 2,0 Application/Limitation The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures. RFOU-VFD is designed for variable frequency drives. Type Approval documentation Tests carried out Standard IEC 60092-350 Issued 2008-02 IEC 60092-351 2004-04 IEC 60092-353 2001-04 IEC 60092-359 IEC 60332-1-2 1999-08 2004-07 IEC 60332-3-22 2009-02 IEC 60754-1 1994-01 IEC 60754-2 1999-07 IEC 61034-1/2 2005-04 General description General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables Single and multicore non-radial field power cables with extruded solid insulation for rated Voltages of 1 kV and 3 kV Sheathing materials for shipboard power and telecommunication cables Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Tests on electric and optical fibre cables under fire conditions – Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A Test on gases evolved during combustion of materials from cables – Determination of the amount of halogen acid gas Test on gases evolved during combustion of materials from cables – Determination of the degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity Measurement of smoke density of cables burning under defined conditions – Test apparatus, procedure and requirements Limitation Bunch test Category A Low Halogen: <0,5% Halogen Halogen free: pH > 4,3 Conductivity < 10µS Low smoke DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 4 of 5 Certificate No.: E-11358 File No.: 827.10 Job Id.: 262.1-002558-5 Standard NEK TS 606 Ed. 4 Issued 2009-05 On special request: IEC 60092-350 2008-02 General description Cables for offshore installations. Halogen-free and/or mud resistant. Technical specification. Limitation Annex E: Procedure 8.9.1: Temperature requirements Cold bend: 40°C Cold impact: 35°C Marking of product DRAKA NORSK KABEL or DRAKA 01 or Prysmian 01 - RFOU P1/P8 or RFCU - size - 0,6/1 kV – IEC 60332-3-22 or DRAKA NORSK KABEL or DRAKA 01 or Prysmian 01 - RFOU VFD – size - 0,6/1 (1,8/3)kV kV – IEC 60332-3-22. Certificate retention survey The scope of the retention/renewal survey is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: • • • • • • Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routine Tests (RT) checked (if RT- and PST-test reports are not available, tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensure traceability between manufacturer's product type marking and Type Approval Certificate. Survey shall be performed at least every second year. END OF CERTIFICATE DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: TA 1411a Issue: October 2009 Page 5 of 5