Tankless Rack System By Rinnai Ojective of Rack System Rinnai’s objective: To supply a packaged water heater solution as fully assembled systems. The system/kit would include all water/gas connections and manifolds under the units. Installer mounts rack system with any necessary venting and connects his utilities at which time the system is ready for operation – Offerings to include; • In-Line or Wall Mount – 2 & 3 unit rack • Back to Back Mount; 2 – 4 or 3 - 6 unit rack • Rack systems can be combined in combinations up to 25 water heaters. 2 Features & Benefits Features and Benefits: • Pre-assembled rack with water heaters installed • Racks can be used with RU98 indoor/outdoor water heaters ONLY • In-Line or Back to Back free standing options • Gas and water manifolds properly sized for each rack system • Rinnai MSB electronic control system available for linking up to 25 units • MCC-91-2 commercial controller available for temperatures between 140˚F and 185˚F 3 Features & Benefits Features and Benefits continue: 4 • Flexible gas/water lines • Drain tees for gas sediment traps • Reinforced eyelets on back to back racks for lifting purposes • Marine grade powered coated aluminum racks • Fully assembled TRS (with water heaters) is designed to fit through a standard 32 inch door Back to Back Assembly Actual 4 Unit Back to Back Rack Assembly 5 Integrated Manifold Integrated Manifolds for both In-line and Back to Back Rack Systems 6 In-Line Frame Design Top Frame – Uni-Strut Vertical legs /Sheet Metal bracing. • • 7 Center Frame Uni-Strut – Galvanized Steel Sheet Metal is 0.090” Aluminum w/powder coat – Frame uses (12) 5/16” threaded bolts to secure the top and center bracing. – Use up to #10 screws to mount to wall studs, 0.219” holes are 2” apart for ease of installation Manifold Data • Manifold Kits – Hot & Cold Water – Type “L” Copper – Manifolds properly sized to handle maximum flow of system – Universal manifold for hot /cold water lines – Gas – Black Iron w/powder coat • Branch Lines – CSST ¾” from water heaters to manifolds - all connections – RIK kits include for hot/cold water feeds to manifold. – ¾” manual shut off or service valve provided for each water heater – ¾” CSST gas branch lines with yellow epoxy coating 8 Lifting Points Proper lifting points for Rack Systems Back to Back lifting requirements In-Line lifting requirements - place straps here 9 MSB System REU-MSB Control System: • The MSB-M main board is supplied with (2) MSB-C1 cables, (one short & one long) to connect the first two units up to the main MSB-M board. • Additional MSB-C1 cables will be needed to connect a third, forth or fifth unit to a MSB board. If installing more than five units the combination of MSB-M boards plus C1 and C2 cables will be determined on site based on the water heater configuration you choose. • Up to 5 MSB-M boards can be linked together with communication cables (MSB-C2’s) allowing up to 25 water heaters to operate as a single system. • An MSB system could have an operating range from 10,000 BTU to as great as 5 million BTU’s in terms of flow rate, from 0.4 gpm to 245 gpm. • When multiple water heaters are linked together with MSB controls, they will attempt to supply equal amounts of hot water. They will also rotated occasionally to ensure equal usage among the entire system. • On initial water flow 1 to 3 units will fire up based on the dip switch configuration of the Main MSB board. Once the flow rate is determined, the MSB board will cycle additional units on or off as needed. Water heaters not firing will close their servo valves. 10 MSB System MSB Control System continue • The temperature setting for all water heaters in a manifold system are controlled by the primary unit connected to the Main MSB board. The temperature controllers connected to other units will display the set temperature selected on the primary unit and cannot be adjusted individually. Additionally they will display error codes and can be used for diagnostics for that particular unit. • If a water temperature over 140 ˚F is desired, the MCC-91-2 controller must be installed on the water heater with the Main MSB board. • Dip switches on the MSB-2M board determine the number of units in standby. It is recommended that the Main MSB-M board dip switches are set for three units to be in the standby mode. All other MSB-M boards should be set to one unit in standby. Place dip switch #1 and #2 on the Main MSB-M board to the “OFF” position, this will place three units in the standby mode. Place dip switch #1 & #2 to the other MSB-M boards to the “ON” position. That will place one unit in those banks in the standby mode. The system will always allow three units to be in standby, as long as the Main MSB-M board is set to three units as explained above. • 11 MSB System MSB Control System (continued) All MSB boards must be set up to communicate with the other boards. This is achieved by setting the dip switches on the MSB boards to the proper positions, follow steps a – e below: a. Set dip switch #3 on the Main MSB board to the “ON” position. b. Set dip switch #4 on the second MSB board to the “ON” position. LED #6 c. Set dip switch #3 & #4 on the third MSB board to the “ON” position. d. Set dip switch #5 on the fourth MSB board to the “ON” position. e. Set dip switch #3 & #5 on the fifth MSB board to the “ON” position 12 Dip switches In all steps, LED #6 will light to confirm connection. TRW02 Specifications In-Line TRW02 Specifications 1 In-Line TRW02 NO. DESCRIPTION QTY. 1 Frame, Top 1 2 Frame, Bottom 1 3 Rinnai Tankless Indoor or Outdoor Unit 2 4 Manifold, Cold Water 1 5 Manifold, Hot Water 1 6 Manifold Gas 1 7 3/4” Dirt Leg 2 8 P1000 Unistrut Channel 2 9 3/4 FNPT Brass Ball Valve - Gas 2 Water and gas flex lines are included on all rack systems. 3 2 8 7 4 5 6 9 13 TRW02 Dimensions In-Line TRW02 Dimensions 14 TRW03 Specifications In-Line TRW03 Specifications In-Line TRW03 1 NO. DESCRIPTION QTY. 1 Frame, Top 1 2 Frame, Bottom 1 3 Rinnai Tankless Indoor or Outdoor Unit 3 4 Manifold, Cold Water 1 5 Manifold, Hot Water 1 6 Manifold, Gas 1 7 3/4” Dirt Leg 3 8 P1000 Unistrut Channel 2 9 3/4 FNPT Brass Ball Valve Gas 3 3 2 8 7 4 5 6 Water and gas flex lines are included on all rack systems. 9 15 TRW03 Dimensions In-Line TRW03 Dimensions 16 TRR04 Specifications Back to Back TRS04 Specification 2 1 Back to Back TRS04 NO. DESCRIPTION QTY. 1 Frame 1 2 Lifting Eyebolt 2 3 Rinnai Tankless Indoor or Outdoor Unit 4 4 Manifold, Cold Water 1 5 Manifold, Hot Water 1 6 Manifold, Gas 1 7 3/4” Dirt Leg 4 8 Unistrut 2 9 3/4 FNPT Brass Ball Valve - Gas 4 3 8 Water and gas flex lines are included on all rack systems. 4 5 6 7 9 17 TRS04 Dimensions Back to Back TRS04 Dimensions 18 TRS06 Specifications Back to Back TRS06 Specification Back to Back TRS06 NO. DESCRIPTION QTY. 1 Frame 1 2 Lifting Eyebolt 2 3 Rinnai Tankless Indoor or Outdoor Unit 6 4 Manifold, Cold Water 1 5 Manifold, Hot Water 1 6 Manifold, Gas 1 7 3/4” Dirt Leg 6 8 Unistrut 2 9 3/4 FNPT Brass Ball Valve - Gas 6 Water and gas flex lines are included on all rack systems. 19 TRS06 Dimensions Back to Back TRS06 Dimensions 20 Rack System Examples Back to Back Application In-Line Application 21 Rack System Examples Back to Back Application 22 Rack System Examples Back to Back Application 23 Clearances for Water Heaters Install the rack system per clearances shown below for the RU98i and RU98e water heaters to top to top to front to front to side to side to floor/ground to floor/ground Indoor models: RU98i 24 Outdoor models: RU98e to Combustibles to NonCombustibles to Combustibles to NonCombustibles inches (mm) inches (mm) inches (mm) inches (mm) Top of Heater 6 * (152) 2 *(51) Top of Heater 12 (305) 2 (51) Back of Heater 0 (zero) 0 (zero) Back of Heater 0 (zero) 0 (zero) Front of Heater 6 (152) 6 (152) Front (panel) 24 (610) 0 (zero) Sides of Heater 2 (51) 1/2 (13) 24 (610) 24 (610) Ground/Botto m 12 (305) 12 (305) 6 (152) 1/8 (3.2) Vent 0 (zero) 0 (zero) 12 (305) 2 (51) Front (exhaust) Sides of Heater Ground/Bottom Piping Layout - 24 Units Manifold Design for 24 W/H’s 2 ½”, 4” and 6” Water Manifolds/Connections Multiple rack systems MUST pipe in parallel as shown below. Piping systems in series will result in undersized water/gas lines. 25 Detailed Piping - 24 Units 26 Rack System Kit Components Tankless Rack System Kit Components 27 Part No.* Rack type Rack P/N TRW02iN 2-unit interior In-line rack, NG RW2 TRW02eN 2-unit exterior In-line rack, NG RW2 TRW02iP 2-unit interior In-line rack, LP RW2 TRW02eP 2-unit exterior In-line rack, LP RW2 TRW03iN 3-unit interior In-line rack, NG RW3 TRW03eN 3-unit exterior In-line rack, NG RW3 TRW03iP 3-unit interior In-line rack, LP RW3 TRW03eP 3-unit exterior In-line rack, LP RW3 Configuration Rack System Kit Components Tankless Rack System Kit Components 28 TRS02iN 2-unit interior back to back rack, NG RS4 TRS02eN 2-unit exterior back to back rack, NG RS4 TRS02iP 2-unit interior back to back rack, LP RS4 TRS02eP 2-unit exterior back to back rack, LP RS4 TRS02iN-IL 2-unit INLINE interior back to back rack, NG RS4 TRS02eN-IL 2-unit INLINE exterior back to back rack, NG RS4 TRS02iP-IL 2-unit INLINE interior back to back rack, LP RS4 TRS02eP-IL 2-unit INLINE exterior back to back rack, LP RS4 TRS03iN 3-unit interior back to back rack, NG RS4 TRS03eN 3-unit exterior back to back rack, NG RS4 TRS03iP 3-unit interior back to back rack, LP RS4 TRS03eP 3-unit exterior back to back rack, LP RS4 TRS04iN 4-unit interior back to back rack, NG RS4 TRS04eN 4-unit exterior back to back rack, NG RS4 TRS04iP 4-unit interior back to back rack, LP RS4 TRS04eP 4-unit exterior back to back rack, LP RS4 Rack System Kit Components Tankless Rack System Kit Components 29 TRS03iN-IL 3-unit INLINE interior back to back rack, NG RS6 TRS03eN-IL 3-unit INLINE exterior back to back rack, NG RS6 TRS03iP-IL 3-unit INLINE interior back to back, LP RS6 TRS03eP-IL 3-unit INLINE exterior back to back rack, LP RS6 TRS05iN 5-unit interior back to back rack, NG RS6 TRS05eN 5-unit exterior back to back rack, NG RS6 TRS05iP 5-unit interior back to back rack, LP RS6 TRS05eP 5-unit exterior back to back rack, LP RS6 TRS06iN 6-unit interior back to back rack, NG RS6 TRS06eN 6-unit exterior back to back rack, NG RS6 TRS06iP 6-unit interior back to back rack, LP RS6 TRS06eP 6-unit exterior back to back rack, LP RS6 Material Details Material Detail List Description (2) RU98 In-Line Mount (3) RU98 In-Line Mount Top Level Part No. RW2 RW3 Rack Frame - Specifications RW2 RW3 Water Heater Model Number RU98i/eN/P RU98i/eN/P Height - in 54.81 54.81 Length - in 41.50 62.00 Depth - in 12.75 12.75 62 x 55 x 36 62 x 75 x 36 Weight - Assembly w/o WHs - lbs 44.1 63.4 Weight - Water Heaters - lbs 131.4 197.1 Weight - Fully Assembled - lbs 175.5 260.5 Weight - Packaging - lbs 121.0 142.0 Weight - Shipping (total) - lbs 296.5 402.5 Crate Dimensions (LxWxH) - in 30 Material Details Material Detail List Description (4/4) RU98 Back to Back (3/4) RU98 Back to Back (2/4) RU98 Back to Back Top Level Part No. RS4-4 RS4-3 RS4-2 Rack Frame - Specifications RF4 RF4 RF4 Water Heater Model Number RU98i/eN/P RU98i/eN/P RU98i/eN/P Frame (HxLxD) - in 55.56 x 41.50 x 28.5 Crate Dimensions (HxLxD) - in 31 62 x 55 x 36 Weight - Assembly w/o WHs - lbs 96.1 88.1 80.1 Weight - Water Heaters - lbs 262.8 197.1 131.4 Weight - Fully Assembled - lbs 358.9 285.2 211.5 Weight - Packaging - lbs 129.0 129.0 129.0 Weight - Shipping (total) - lbs 487.9 414.2 340.5 Material Details Material Detail List Description (6/6) RU98 Back to Back (5/6) RU98 Back to Back (3/6) RU98 Back to Back Top Level Part No. RS6-6 RS6-5 RS6-3 Rack Frame - Specifications RF6 RF6 RF6 Water Heater Model Number RU98i/eN/P RU98i/eN/P RU98i/eN/P Frame (HxLxD) – in 55.56 x 62.00 x 28.5 Crate Dimensions (LxWxH) - in 32 62x75x36 Weight - Assembly w/o WHs - lbs 124.6 116.6 100.6 Weight - Water Heaters - lbs 394.2 328.5 197.1 Weight - Fully Assembled - lbs 518.8 445.1 350.2 Weight - Packaging - lbs 148.0 148.0 148.0 Weight - Shipping (total) - lbs 666.8 593.1 498.2 Materials Details Material Detail List Description (2, 3) RU98 In-Line Mount Top Level Part No. RW2, RW3 (4/4, 3/4, or 2/4) RU98 Back to Back (b) (6/6, 5/6, 3/6) RU98 Back to Back (b) RS4-4, RS4-3, RS4-2 RS6-6, RS6-5, RS6-3 Rack Frame - Specifications RW2, RW3 RF4 RF6 Frame Rail Type Sheet Metal Sheet Metal Sheet Metal 0.090 5052-H32 0.090 5052-H32 0.090 5052-H32 Powder Coat Powder Coat Powder Coat Gray Gray Gray Hot Water Trunk Line Diameter 2" 2" 2-1/2" Cold Water Trunk Line Diameter 2" 2" 2-1/2" Hot Water Trunk Line Material Rigid Copper Rigid Copper Rigid Copper Cold Water Trunk Line Material Rigid Copper Rigid Copper Rigid Copper Water Trunk Connection Type 2" MNPT 2" MNPT 2-1/2" MNPT Water Header End Cap (field supplied) 2” FNPT 2” FNPT 2-1/2” FNPT Hot Water Branch Line Diameter 3/4" 3/4" 3/4" Cold Water Branch Line Diameter 3/4" 3/4" 3/4" Hot Water Branch Line Material CSST CSST CSST Frame Material Frame Finish Color Water & Gas Connections 33 Material Details Material Detail List continue from previous slide Cold Water Branch Line Material CSST CSST CSST 1-1/4" NPT 1-1/4" NPT 1-1/2" NPT Gas Trunk Connection Type 1-1/4” MNPT 1-1/4” MNPT 1-1/2” MNPT Gas Header End Cap (field supplied) 1-1/4” FNPT 1-1/4” FNPT 1-1/2” FNPT Gas Trunk Line Material Sch 40 Steel Sch 40 Steel Sch 40 Steel Gas Branch Line Diameter 3/4" 3/4" 3/4" Gas Branch Line Material PVC over CSST PVC over CSST PVC over CSST Powder Coat Powder Coat Powder Coat Uni-Strut Size 1-5/8" x 13/16" 1-5/8" x 1-5/8" 1-5/8" x 1-3/8" Uni-Strut Material 14ga Steel / Zn 12ga S/S 12ga S/S Steel / Zn S/S 18-8 S/S 18-8 Gas Trunk Line Diameter Gas Trunk Line Finish Hardware Material/Finish 34 Electrical/Flow Ratings Electrical /BTU Input Ratings Each water heater requires 120 VAC, 60 Hz. 4 amp power source in a properly grounded circuit. Electrical Requirements (Installer shall provide electrical outlet connections) Each unit has a 10 amp fuse. Maximum circuit for each RU98 unit without a built-in circulation pump is 4 amps. RU98i: 64 W normal operation; 2 W standby; 146 W anti-frost protection. RU98e: 63 W normal operation; 2 W standby; 168 W anti-frost protection. BTU and Flow Rates for Common Vented RU98i/e (NG/LP) 2 RU98 3 RU98 4 RU98 6 RU98 Flow rate @ 70°F temperature rise (gpm) 10.8 16.2 21.6 32.4 Flow rate @ 100°F temperature rise (gpm) 7.6 11.4 15.2 22.8 398,000 597,000 796,000 1,194,000 Maximum input rate (Btuh) 35 The End Rinnai Rack System Training Version 02282014GW