Interface Gold Standard Calibration System INTERFACE Developed in 1989, Interface, Inc. began to market the Gold Standard™ System in 1991. It is now used in more than 250 labs throughout the world. INTERFACE Gold StandardTM Load Cell Calibration System One 9840 2 Channel Indicator for Load Cell Exitation/ Signal Conditioning One ICS-202 Force Calibration Software One SIS-103 One-Day Training at Interface One CT-139-10 SCB1 to GS Load Cell Cable One CT-142-10 SCB1 to Standard Load Cell Cable One CX-0440 mV/V Transfer Standard One SIS-104 System Setup INTERFACE Interface Gold StandardTM Calibration Systems Controlled calibration process reduces calibration times by 50% to 90% and produces consistent calibration results Easy-to-use software reduces operator training time Fully integrated reporting functions Automatic archiving of calibration results Supports ASTM E74, ASTM E4 and ISO 7500/1, EH10002 Industry Accepted terms and calculations 0.1µV display resolution Used in over 250 calibration labs world-wide INTERFACE Gold StandardTM Calibration System Options GS-USB: Provides USB interface for HRBSC, SCB1, DA-101 and HL4IO instrument boards includes internal power supply, cooling fan and USB cable. SCB1: 20 bit instrument board provides signal conditioning for the Gold StandardTM System. Available in single or dual channel versions. HRBSC: High-resolution 22 bit instrument board increases accuracy over the SCB1. DA-101: Digital to analog board for generating command signal for system control. Provides setpoint signal for servo controlled hydraulic force testing. HL4IO: High level 4-channel input board allows calibration of ±5 and ±10 VDC output transducers and includes all features of the DA-101. Load Cell Simulator: mV/V transfer standards are used to calibrate the Gold StandardTM system, and for setting up and testing load cell readout devices. CX-0404 - specifically designed for instrument substitution testing as per ASTM E74. Desktop, laptop or portable PC: Contact factory for currently available configurations. Gold StandardTM or Platinum StandardTM load cells as required. INTERFACE 1600 Gold StandardTM Calibration Load Cell Tension and compression in one unit .005% nonrepeatability .01% creep High output - to 4mV/V High precision base installed 3 run NIST traceable calibration Factory installed calibration adapter Eccentric load compensated .0008%/°F temp. effect on output 4% lower load limit per ASTM E74 INTERFACE 1600 Gold StandardTM Calibration Compression Only Load Cell .005% nonrepeatability .01% creep High output - to 4mV/V High precision base installed 3 run NIST traceable calibration Eccentric load compensated .0008%/°F temp. effect on output 4% lower load limit INTERFACE Model 1800 Platinum™ Series Low Profile Load Cells .005% non-repeatability .01% Creep Designed to be used at 2% lower load limit .008% /°F temp effect on output Eccentric load compensated INTERFACE Model 9840 Intelligent Indicator • 24 bit internal resolution •+/-999,999 Count Bipolar Display •Nonlinearity < 0.005% •Stores calibration for up to 25 load cells •Fast, direct analog output • VDC scalable analog output •Full duplex RS232C •Peak/Valley hold •Front panel and remote tare INTERFACE Precision mV/V Load Cell Simulator Most accurate load cell simulator. Special low thermal emf construction. Each unit individually calibrated, aged and recalibrated. Strong, rugged design. Instrument substitution testing. MDL CX-0404 is specifically designed for instrument substitution testing as per ASTM E74. Why use a simulator or mV/V Standard ? Calibrate Indicator or Signal Conditioner periodically Daily sanity check on measurements Establish true zero Check cables 11 Model CX Standard 6 digit calibration 10 ppm uncertainty 12 Shunt Calibration Technique of unbalancing bridge with external shunt resistor Less Expensive OK for medium-accuracy work Affected by preload, temperature, bridge resistance drift, cable length 13 Transducer Calibration Procedures 14 Machine Calibration Procedures 15 Measurement Uncertainty Model, Calibrating Load Cell by Comparison Load Frame Monitor Printer Test Transducer HRBSC Standard Transducer HRBSC Computer Gold Standard Software Data Archive Feedback Transducer Servo Amplifier & Controller Hydraulic Force Generator Servo Valve 16 Uncertainty Components CNS = Cal of Standard Transducer by NIST DS = Drift in Standard since last cal PS = Creep in Standard Transducer TS = Temperature effect on output of Standard RHF= Nonreproducibility of frame, load string CH = Calibration of HRBSC Instrument DH = Drift in HRBSC since last cal TH = Temperature effect on HRBSC Instrument LH = Nonlinearity of HRBSC Instrument NH = Noise of HRBSC Instrument 17 CH Uncertainty in calibration of HRBSC (rectangular distribution) Source of Uncertainty Type Uncertainty (%RDG) CCX = Calibration of CX-0610 B 0.0008 DCX = Drift in transfer function of CX-0610 between calibrations B 0.0010 TCX = Temperature effect on CX-0610 B 0.0054 NCX = Noise of the HRBSC instrument during calibration with the CX-0610 B 0.0003 -----------Combined (Root Sum of Squares) 0.0056 18 Uncertainty Budget Example Analysis at 30% Calibrated Range and 0.9 mV/V Output of the Standard and Test Transducers: Source of Uncertainty CNS NIST Cal of Standard, uw Type Interval Interval Expression (%RDG) Probability Distribution Uncertainty ui (%RDG) Factor B 0.0005% RDG 0.0000 Std Dev 1 0.0000 uv B 0.0005% RDG 0.0000 Std Dev 1 0.0000 ur A 0.00160%Cal Range 0.0000 Std Dev 1 0.0000 DS Drift in Standard B 0.010% RDG 0.0000 Triangular 0.408 0.0000 PS Creep in Standard B 0.0055% RDG 0.0000 Rectangular 0.577 0.0000 TS Temperature Effect on Std B 0.0029% RDG 0.0000 Rectangular 0.577 0.0000 RHF Nonreproducibility , load frame B 0.0130% RDG 0.0000 1 0.0000 CH Cal of HRBSC, Std B 0.0056% RDG 0.0000 Rectangular 0.577 0.0000 DH Drift in HRBSC, Std A 0.0009% RDG 0.0000 1 0.0000 TH Temperature Effect HRBSC, Std B 0.0020% RDG 0.0000 Rectangular 0.577 0.0000 LH Nonlinearity of HRBSC, Std B 0.00007 mV/V 0.0000 0.408 0.0000 NH Noise of HRBSC, Std B 0.00004 mV/V 0.0000 Rectangular 0.577 0.0000 CH Cal of HRBSC, Test B 0.0056% RDG 0.0000 Rectangular 0.577 0.0000 DH Drift in HRBSC, Test A 0.0009% RDG 0.0000 1 0.0000 TH Temperature Effect HRBSC,Test B 0.0020% RDG 0.0000 Rectangular 0.577 0.0000 LH Nonlinearity of HRBSC, Test B 0.00007 mV/V 0.0000 0.408 0.0000 NH Noise of HRBSC, Test B 0.00004 mV/V 0.0000 Rectangular 0.577 0.0000 Std Dev Std Dev Triangular Std Dev Triangular uc Combined Uncertainty Root Sum of Squares Method 0.0000 U Expanded Uncertainty U = k uc w here k = 2 for confidence level of 95% 0.040 19 Dominant Uncertainty Components Nonreproducibility of load frame, threads, adaptors, alignment Calibration of Standard at low end of range Drift in Standard since last cal 20 INTERFACE Load Cell Calibration System Software - Opening Screen INTERFACE DUT Description INTERFACE Setpoint Entry INTERFACE Setpoint File Selection Exercise Load Cells INTERFACE INTERFACE Begin Calibration Calibration INTERFACE INTERFACE Completed Calibration INTERFACE Error Plot INTERFACE Curve Fit INTERFACE Load Cell History INTERFACE INTERFACE Model: 1210AF-1K Serial: 52689A Capacity: 1000 lbf Date: 06-08-2004 0.1 0.08 0.06 Error, %FS 0.04 0.02 0 -0.02 -0.04 -0.06 -0.08 -0.1 0 10 20 30 40 50 60 Test Range, % (1000 lbf COMPRESION) RUN 1 RUN 2 RUN 3 70 80 90 100 INTERFACE Report Designer Custom Report INTERFACE INTERFACE Gold StandardTM E4 Machine Calibration System 9840-100-1 Intelligent Indicator One ICS-205 E4 Machine Calibration Software One CT-177-10 Gold Standardtm Interconnect Cable Assemby Serial Cable, Laptop to 9840 One CX-0440 +4mV/V Transfer Standard One SIS-104 System Setup Training at Interface INTERFACE Features of the Portable E4 Machine Calibration Software: Capable of providing the user with printed copies of: E4-02 Test Machine Verification Report. ISO 7500/1 Test Machine Verification Report. INTERFACE Portable E4 System Software – Opening Screen INTERFACE Setpoint Entry INTERFACE Setpoint File Selection INTERFACE Meter Configuration INTERFACE Machine Details INTERFACE Load Point Entry INTERFACE Load Point Entry Begin Verification INTERFACE INTERFACE Data Collection INTERFACE Completed Verification INTERFACE E4 Report INTERFACE Verification History INTERFACE ISO 7500-1 Report INTERFACE ISO 7500-1 INTERFACE Report Designer INTERFACE Custom E4 Report INTERFACE Custom ISO Report