AN INTRODUCTION TO THE BTS-1000 (BERD DAWG) COMMUNICATIONS TEST SET SLIDE 1 OF 22 This presentation is designed to give you an overview of all the keys, buttons, displays and other gadgets on the front panel of the Digital Interface in your BTS-1000 Test Set. Please refer to your USER’S MANUAL for more information about any of the functions discussed here. If you have any questions, please feel free to contact us at your convenience at don.brehm@itcmail.net, or 402-498-8400. TO VIEW THIS PRESENTATION, USING PowerPoint, SELECT [View] AND [Slide Show]. USE YOUR COMPUTER [PAGE UP] OR [PAGE DOWN] KEYS, OR CLICK ANYWHERE ON THE SLIDE TO ADVANCE. THE [HOME] KEY WILL TAKE YOU TO THE FIRST SLIDE. THE [END] KEY WILL TAKE YOU TO THE LAST SLIDE. TO REVIEW WHAT YOU’VE DONE, SELECT THE KEY YOU’D LIKE TO SEE AGAIN: MAIN SCREEN Function, Selection, Text RSD232 & DDS Ports DS1 RCV/XMT Keys HELP Key HOME Key MAIN MENU Title, Screen #, Side # OPTION CONTROL (Key Pad) FUNCTION Keys NEXT Key Display Circuit Status Lines Jack Field AUX ACCESS Jacks PREV Key SLIDE 2 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA VOLUME VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON OFF ON POWER POWER BRIDGED Starts the whole thing! TERM POWER -Turns Startson thepower whole thing! -Starts self diagnostics RCV1 RCV2 F1 F2 F3 -Turns on power -Starts self diagnostics 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL F4 F5 F6 HELP ENTER NEXT PREV HOME SLIDE 3 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA RS-232 (DCE) MAIN SCREEN This screen or your VF Corporate ACCESS Logo will appear at Power-ON, RCV run XMTit’sE&M after the test set has DS1 ACCESS SIDE 1 self diagnostics. RCV VOLUME XMT Press any F key to go to the SIDE 2 MAIN MENU. DSX-MON BRIDGED TERM OFF 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 4 OF 22 BTS1000 (BERD DAWG) Interface MAIN MENU All tests start at the MAIN MENU. AUX ACCESS DS0 DATA VOLUME Press HELP here to view calibration dates, options installed, software version ABC DEF STP 1 2 Number 3 Afor this test set. and the Serial VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 5 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA DISPLAY SCREEN Shows set up options and status, and VOLUME results of tests. VF ACCESS ABC DEF STP Move next slide for more 1 to the 2 3 A information about this screen. GHI JKL MNO ST2P RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF 4 5 6 B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 6 OF 22 BTS-1000 MAIN DISPLAY SCREEN Selection text follows to the right of each key. When a selection is made with the function key, a box is drawn around the selection. FUNCTION KEYS These are Menu selection key indicators. When these keys are displayed with boxes around them they are functional, regardless of screen type (SET-UP, RESULT or CONFIGuration) and the displayed location of the keys, the operation is as defined in the HELP screen text. SLIDE 7 OF 22 BTS-1000 MAIN DISPLAY SCREEN SIDE NUMBER The SIDE NUMBER refers to DS1 RCV1 or DS1 RCV2. If SIDE ONE is showing, selections and test results are related to the DS1 RCV1 input. TITLE The text that appears in the title location always refers to the Main Menu selection and if this is a SET-UP, RESULT, or CONFIGuration screen. SCREEN NUMBER This number allows the user to track the selected screen’s position within the total number of SETUP or RESULT screens. SETUP screens always precede RESULT screens. Use the NEXT [NXT] and PREVious [PRV] keys to select the next or previous screen. SLIDE 8 OF 22 BTS-1000 MAIN DISPLAY SCREEN CIRCUIT STATUS LINE This line appears on all screens that relate to DS1 and DSØ testing. The line is divided with SIDE 1 information on the left and SIDE 2 information on the right. The information contained in the Status Line is a blend of MENU SELECTIONS, CIRCUIT ALARM CONDITIONS, CIRCUIT ERROR CONDITIONS and CURRENT CIRCUIT OPERATIONAL STATUS. SIDE 1 Information See next two slides. SIDE 2 Information See next two slides. SLIDE 9 OF 22 BTS-1000 MAIN DISPLAY SCREEN FRAME FORMAT Selectable - SF, ESF or AUTO LINE CODE Selectable - AUTO, AMI, B8ZS SLIDE 10 OF 22 BTS-1000 MAIN DISPLAY SCREEN ALARM & ERROR STATUS When any of these DS1 circuit alarms occur (LOS, AIS, LOF, RAI) a flashing A will appear. When any of these DS1 circuit errors occur (BPV, EXZ, FE, SLIP, B8ZS, CRC-6) a flashing E will appear. CIRCUIT STATUS The letters FRM indicate that the circuit is framed and operational. All other indications such as LOS, AIS, RED, YEL are indications of a circuit that is not fully operational. SLIDE 11 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA VF ACCESS DDS PORT This 9 PIN connector is used to connect various DDS test sets and other protocol analyzers. This is an input (TTL) and output port. RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF VOLUME 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV2 F1 F2 (DCE) F3 F4 F5 RS232C This port is set up as a DCE Modem connector, which enables the Digital Option Package to connect directly to a DTE device such as a computer, printer or remote control terminal. RCV1 F6 HELP NEXT PREV HOME SLIDE 12 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA RS-232 (DCE) OPTION CONTROL (KEY PAD) ACCESS The 4 x 4 keyVFpad is used to enter dial digits, select stored tests, select or cancel choices from a RCV XMT E&M CONFIGuration screen, and other functions being DS1 ACCESS SIDE 1 developed. RCV VOLUME XMT SIDE 2 DSX-MON BRIDGED TERM OFF 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 13 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA VOLUME VF ACCESS VF ACCESS JacksABC DEF STP 1 2 3 an A The VF ACCESS jacks are for connecting GHI JKL MNO auxiliary test set to a selected DS0 circuit forST2P 4 5 6 B further analog or digital tests. PRS TUV WXY ST3P RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT 7 SIDE 2 DSX-MON KP * BRIDGED TERM OFF CANCEL 8 9 C 0 ST # D ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 14 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA VOLUME VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV 1 DEF 3 GHI JKL MNO DS1 SIDE 1 & SIDE 2 RCV/XMT Jacks 4 5 6 These jacks are used to connect the to PRS test TUVset WXY 7 8 9 the circuit under test. ST The LEDs indicate which jacks areKPactive. 0 # * XMT SIDE 2 DSX-MON BRIDGED TERM OFF ABC 2 CANCEL STP A ST2P B ST3P C D ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 15 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA VF ACCESS RS-232 (DCE) AUXILLIARY ACCESS This location is reserved RCV XMT E&M ACCESS for future options. DS1SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF ON POWER RCV1 RCV2 F1 DS1 RCV1/RCV2 Keys These keys are used to select the correct receiver impedance for the VOLUME selected test location. The impedance selection is indicated by the two LEDs above each key. ABC DEF STP 1 2 3 A TERM is selected when the test set terminates the DS1 circuit. The GHI JKL MNO ST2P TERM LEDs are lit. 4 5 6 B BRIDGE is selected if a high impedance required. Both LEDs are PRS TUV input WXY is ST3P 7 8 9 C lit. The BRIDGE mode must access a terminated cable pair for readings to ST D be accurate. This is the POWERKP ON default 0 # mode. * MONITOR is used for resistive CANCEL monitor jack applications. The MON LED ENTER will be lit. Note: If the MONITOR jack is not resistor isolated, use the BRIDGED F2 F3 F4 F5 F6 HELP NEXT PREV HOME mode. SLIDE 16 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA FUNCTION Keys F1 - Selects STORED TESTS where available,. VOLUME F2 - Selects DS1 PERFORMANCE MONITOR tests. F3 - Selects DS1 BERT tests. ABC DEF STP 1 tests. 2 3 A F4 - Selects DS0 DROP & INSERT JKL MNO ST2P F5 - Selects the test set SYSTEMGHISETUP functions. 4 5 6 B F6 - Selects other test functions when available. PRS TUV WXY ST3P 8 9 C tests. All keys select additional functions7 within specific VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON KP * BRIDGED TERM OFF CANCEL 0 ST # D ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 17 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA HELP Key This key is used to select the built-in user’s manual. The HELP screen VOLUME displayed will be directly related to the screen that was displayed before entering HELP. The NEXT and PREV keys will access all additional ABC DEF STP 1 2 3 A HELP screens related to the screen showing. GHI JKL MNO ST2P Use HOME to return to the test screen. 4 5 6 B VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 18 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA NEXT Key This key is used to move to the next screen in the set up, help or test VOLUME process. VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 19 OF 22 BTS1000 (BERD DAWG) Interface PREV Key This key is used to move to the previous screen viewed in the set up, help or test process. VOLUME AUX ACCESS DS0 DATA VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 20 OF 22 BTS1000 (BERD DAWG) Interface AUX ACCESS DS0 DATA HOME Key This key is used to escape from any screen to the Main Menu, or return VOLUME from a HELP or CONFIGuration screen to the screen that was previously chosen. VF ACCESS RS-232 (DCE) RCV XMT E&M DS1 ACCESS SIDE 1 RCV XMT SIDE 2 DSX-MON BRIDGED TERM OFF 1 ABC 2 DEF 3 STP A GHI 4 JKL 5 MNO 6 ST2P B PRS 7 TUV 8 WXY 9 ST3P C KP * 0 ST # D CANCEL ENTER ON POWER RCV1 RCV2 F1 F2 F3 F4 F5 F6 HELP NEXT PREV HOME SLIDE 21 OF 22 CONGRATULATIONS !!! You made it through this document. That’s a good thing!! Now refer to your manual to set up and run a test. We appreciate you support and your business. If you have any questions please contact us at 402-498-8400 or email - don.brehm@itcmail.net. SLIDE 22 OF 22