SmartVFD HVAC, BYPASS, NXL, NXS Introduction 1 Honeywell SmartVFD – Today and tomorrow SmartVFD HVAC 480 VAC – 1.5-250HP 230VAC – 1–125HP 575VAC - 1-150HP Graphic Interface Std fieldbus protocals 2 SmartVFD BYPASS SmartVFD HVAC Disconnect 2-Contactor 3-Contactor Auto-Bypass & HOA SmartVFD COMPACT 480 VAC .5-7.5HP 208/230VAC, 1~in, .25-3HP 208/230VAC, 3~in .25-3HP 115VAC, 1~in .15-1.5HP 575Vac, 1HP-7.5HP NEMA1 Kit Modbus Std SmartVFD HVAC • • • • • Intuitive Interface Easy Commissioning Standard Communication Reliable Protection Effective Operation/Monitoring The SmartVFD for Smart Buildings 3 Intuitive Interface • • • • • • • High resolution Intuitive commissioning Manual in keypad Help screens Real time clock Local/Remote Button Memory in keypad Intuitive, Effective, Consistant SMART 4 Easy Communications • Standard - RS485 BACnet N2 Modbus - Ethernet Modbus/TCP BACnet/IP - Option Cards LonWorks Profibus CANopen DeviceNet Ethernet Built-in Communications 5 Built-In Protection • DC Choke - Built in resistors for upfront protection • Varnished boards • RFI filter standard • Built in Fan - NEMA12 extra fan Harmonic, RFI, Environmental Protection 6 SMART Software • Start-up Wizard – Pump/Fan • Power loss ride through • Fire mode • Pump and Fan Cascade • Ramp Time Optimizer • Maintenance Counters • Pump Soft Fill • 2 PID Controllers The SmartVFD for Smart Buildings 7 SmartVFD BYPASS • • • • • Low total installed cost Compact size Easy component access NEMA 1, 12, 3R All configurations - Disconnect - 2-contactor - 3-contactor - 3-contactor with AutoBypass, HOA H e ig h t C o m p a ris o n 2 c tr (1 - 7 .5 H P ) 3 c tr (1 - 7 .5 H P ) 2 c tr (1 0 -2 0 H P ) 3 c tr (1 0 -2 0 H P ) 2 c tr (2 0 -4 0 H P ) 3 c tr (2 0 -4 0 H P ) 8 C o o l B lu e 4 0 in 4 0 in 4 6 in 4 6 in 5 3 in 5 3 in N ext G en 3 0 in 3 7 in 3 3 in 4 0 in 4 3 in 5 3 in Features 9 Bypass Options 10 Smart VFD HVAC Mechanical Construction MR4 •Panel •Main DC Fan •Heatsink •IP54 Fan •Rectifying , •brake and IGBT •DC Choke •Control •assembly •Power Board •DC Capacitor 11 •GND Plates •IP21 or 54 •Plates and •sealing Smart VFD HVAC Cabling •Sealing • No throughput clamps needed in IP21 • No throughput clamps needed in IP54 •EMC • 360 % grounding with easy clamps inside the drive (consertrig) •Input cables • MCMK no shield needed •Motor cables • Max lenght • MR4 100m • MR5 and MR6 150m • MR7 200m • C2 MCCMK and C3/IT MCMK •Grounding • 2 PE wires needs to be connected to ground to fulfill EN61800-5-1. •Fuses and cable sizes MR4-9 • Chapter 4.1.1.X in installation manual 12 Smart VFD HVAC Fieldbus RS-485 • RS485 2 Wires always included in Vacon 100 HVAC: - BACnet - N2 - Modbus • RS485 4 Wires - Keypad - PC Tools 13 •RS-485 4W •RS-485 2W Smart VFD HVAC Fieldbus Ethernet • Ethernet module is integrated to the main processor • Supported General Protocols - TCP/IP (basic protocol) DHCP, AUTOIP, IPConfig FTP (Future Option) HTTP, simple web browser interface (Future option) • Supported Industrial Protocols - Modbus/TCP - BacNet IP - Vacon HMI protocol (for PC tool usage) - Ethernet/IP and Profinet (Future option) • Cable max lenght 100m (to switch) •Ethernet 14 Smart VFD HVAC Control Board •ARM9 Processor (200MHz) •Flash Memory 32Mb •RAM Memory 128Mb 15 www.honeywell.com