iVu Imaging Corporation Intelligent Volumetric Ultrasound iVu The Breast Problem • Breast cancer is the leading cause of death among women aged 35 to 54 in the industrialized world • Every Two (2) minutes a woman is diagnosed with breast cancer • 1,300,000 women are diagnosed with breast cancer each year • 465,000 women die of breast cancer per year • 40% of the screening population have dense breast tissue. – Mammography is ineffective at visualizing abnormal anatomical features in dense breast tissue • Early detection is key to successful treatment and survival Intelligent Volumetric Ultrasound iVu The Breast Problem Intelligent Volumetric Ultrasound iVu The Breast Problem • Mammography – Painful breast compression – Ionizing radiation exposure – High False positive and False negative rates • Over One Million unnecessary breast biopsies per year • Misses 40% of cancer in dense breast patients • Manual Ultrasound – Technique and technician dependent – Time consuming exam • MRI – Expensive modality – Long exam times – Invasive procedure requiring injection of contrast agent Intelligent Volumetric Ultrasound iVu The Breast Solution Advanced Tomographic Ultrasound: • Automated Image Acquisition of Anatomically Correct Breast Tissue (3 Minute Whole Breast Scan) • Rapid and comfortable exam procedure • Operator independent (Reproducible Consistent Results) • 3D / MPR Visualization and Analysis • Virtual Dissection Tools • DICOM / PACS Compliant with Tele-Radiology Applications Intelligent Volumetric Ultrasound iVu The Breast Solution Benefits • Patients – No radiation – Comfortable exam – Patient Privacy • Radiologists – Anatomically correct High Definition Whole Breast images – 3D / MPR Analysis Tools • Financial Decision Makers – Increased patient throughput – Decreased sonographer attended time per patient Intelligent Volumetric Ultrasound iVu Automated Breast Tomography System Intelligent Volumetric Ultrasound iVu Consistent and Reproducible Automated Image Acquisition Intelligent Volumetric Ultrasound iVu Intelligent Volumetric Ultrasound iVu Increased Compliance with Comfortable Exam Pendulous Breast in Warm Fluid Bath Enhanced Patient Privacy Intelligent Volumetric Ultrasound iVu 2D Image Review – Abnormal Dense Breast Intelligent Volumetric Ultrasound iVu 2D Image Review – Abnormal Dense Breast Full Width Axial view Intelligent Volumetric Ultrasound iVu Intelligent Volumetric Ultrasound iVu Imaging Corporation Intelligent Volumetric Ultrasound Turkey & Middle East & Asia Distributor www.ugemedicalgroup.com.tr info@ugemedicalgroup.com.tr Tel: +90 212 284 19 25 (pbx) Fax: +90 212 284 66 67