Femtosecond-Laser Assisted Cataract Surgery: Is it living up to the hype? 117th Annual Meeting of the American Academy of Ophthalmology Press Briefing Nov. 18, 2013 Introduction of Speakers Bret L Fisher, M.D., medical director of the Eye Center of North Florida Visual Acuity and Predictability in Femtosecond Laser Cataract Surgery With Intraoperative Aberrometry Mike P Holzer, M.D., vice chairman and director of refractive surgery, Department of Ophthalmology, University of Heidelberg, Germany Single-center Contralateral Evaluation of Femtosecond Laser Cataract Surgery Compared with Manual Cataract Surgery Tim Schultz, M.D., Department of Ophthalmology, University Hospital Bochum, Germany Toward the Elimination of Ultrasound With Femtosecond Laser Cataract Surgery AMERICAN ACADEMY OF OPHTHALMOLOGY WWW.AAO.ORG Visual Acuity and Predictability in Femtosecond Laser Cataract Surgery With Intraoperative Aberrometry Presented by: Bret Fisher, M.D. The Eye Center of North Florida Panama City, FL Financial Disclosures • Alcon - Consultant and Lecture Fees Purpose • To determine the impact of intraoperative aberrometry on uncorrected visual acuity and predictability (MAVPE) in Femtosecond laser cataract surgery Background • Outcomes analysis in the literature Narvaez / Stulting JCRS Dec. 2006 643 eyes • 46 % within 0.50 D of formula predicted target • MAVPE: 0.52 D ± 0.44 D Gale et al, Eye Aug. 2007 4806 eyes (2688 in the PCI group) ▫ PCI group results • 55 % of eyes within 0.50 D of formula predicted target • 85% of eyes within 1.00 of formula predicted target • MAVPE: 0.55D ± 0.55D • Behndig et al, JCRS July 2012 • 17,506 case (performed between 2008-2010) • 55% achieved refractive target (0.00 D sphere ,<1.00 D of astigmatism • MAVPE: 0.50 D ± 0.34 D Method • One surgeon • No postrefractive cases • Retrospective analysis of eyes within the following groups: ▫ Group 1 – Consecutive cases that had cataract surgery with IOL implantation utilizing a femtosecond laser (LenSx®) without intraoperative wavefront aberrometry (ORA System®) ▫ Group 2 – Consecutive cases that had cataract surgery with IOL implantation utilizing a femtosecond laser (LenSx) in combination with intraoperative wavefront aberrometry (ORA System) Baseline Characteristics Group 1 – Femtosecond Laser Only • 55 eyes of 55 patients • 23 of 55 (42%) male • 32 of 55 (58%) female Age Preoperative Flat K Preoperative Steep K Preop Keratometric Cylinder Axial Length White to White Mean 69 42.99 43.86 0.87 24.31 12.11 Min 36 39.78 41.27 0 21.77 11.08 Max 82 46.62 47.4 6.34 29.69 13.1 Standard Deviation 9 1.47 1.50 0.95 1.60 0.49 SN60WF SN6AD1 SN6ATx 30 (55%) 17 (31 %) 8 (14 %) Baseline Characteristics Group 2 – Femtosecond Laser and Intraoperative Aberrometry • 66 eyes of 50 patients •22 of 50 (44%) male •38 of 50 (56%) female Age Preoperative Flat K Preoperative Steep K Preop Keratometric Cylinder Axial Length White to White Mean 66 43.37 44.28 0.90 23.59 12.20 Min 22 39.56 39.95 0 21.31 11.44 Max 84 46.68 47.35 4.59 26.07 13.24 Standard Deviation 11 1.45 1.63 0.70 0.95 0.44 SN60WF SN6AD1 SN6ATx 26 (40%) 32 (48%) 8 (12%) Uncorrected Distance Visual Acuity (UCDVA) Results Group 1 - Femtosecond Laser Only 100% n = 55 eyes 87% 80% 76% 60% 44% 40% 18% 20% 13% 2% 0% ≤ 20/15 Logmar Equivalent ≤ 20/20 ≤ 20/25 ≤ 20/30 ≤ 20/40 > 20/40 Mean Standard Deviation Min Max 0.18 0.21 -0.12 1 Uncorrected Distance Visual Acuity (UCDVA) Results Group 1 - Femtosecond Laser Only Eyes Targeted for Distance 100% 90% n = 49 eyes 82% 80% 60% 49% 40% 20% 20% 10% 2% 0% ≤ 20/15 Logmar Equivalent ≤ 20/20 ≤ 20/25 ≤ 20/30 ≤ 20/40 > 20/40 Mean Standard Deviation Min Max 0.17 0.17 -0.12 1 *Eyes targeted for distance only Mean Absolute Value Prediction Error (MAVPE) Results Group 1 – Femtosecond Laser Only 100% 89% n = 55 eyes 93% 80% 69% 60% 40% 29% 20% 7% 0% ≤ 0.25 ≤ 0.50 ≤ 0.75 ≤ 1.00 > 1.00 Mean Standard Deviation Min Max 0.42 D 0.31 D 0.01 D 1.34 D Uncorrected Distance Visual Acuity (UCDVA) Results Group 2 - Femtosecond Laser and Intraoperative Aberrometry 100% 94% n = 66 eyes 83% 80% 67% 60% 40% 33% 20% 6% 2% 0% ≤ 20/15 Logmar Equivalent ≤ 20/20 ≤ 20/25 ≤ 20/30 ≤ 20/40 > 20/40 Mean Standard Deviation Min Max 0.12 0.14 -0.12 0.54 Uncorrected Distance Visual Acuity (UCDVA) Results Group 2 - Femtosecond Laser and Intraoperative Aberrometry 100% 100% 92% n = 60 eyes 80% 73% 60% 37% 40% 20% 2% 0% 0% ≤ 20/15 Logmar Equivalent ≤ 20/20 ≤ 20/25 ≤ 20/30 ≤ 20/40 > 20/40 Mean Standard Deviation Min Max 0.09 0.09 -0.12 0.30 *Eyes targeted for distance only Mean Absolute Value Prediction Error (MAVPE) Results Group 2 – Femtosecond Laser and Intraoperative Aberrometry 100% 100% 94% n = 66 eyes 80% 80% 60% 52% 40% 20% 0% ≤ 0.25 ≤ 0.50 ≤ 0.75 ≤ 1.00 Mean Standard Deviation Min Max 0.31 D 0.24 D 0.01 D 0.97 D Advances in Intraoperative Aberrometry ORA System with VerifEye • Function: Provides streaming refractive information to the surgeon during preview (prior to measurement) • Provides: High quality measurements ▫ Verifies that the eye is stable and ready for measurement • Result: Greater consistency and accuracy IOL power recommendations Guidance for astigmatic measurements • Shorter measurement time Faster processor 2 seconds for measurement 3 seconds for processing VerifEye Mean Absolute Value Prediction Error (MAVPE) Results Group 2 – Femtosecond Laser and ORA with VerifEye n=26 eyes Mean Standard Deviation Min Max 0.30 D 0.21 D 0.01 D 0.85 D Summary • Femtosecond laser (FSL) assisted cataract surgery provided refraction outcomes that are better that those reported in literature • FSL combined with Intraoperative aberrometry provided better UDVA than FSL alone ▫ Difference in mean acuity is statistically significant (p<0.03) • FSL combined with Intraoperative aberrometry provided better refractive outcomes (as measured by MAVPE) than FSL alone ▫ Difference in mean acuity is statistically significant (p<0.04) Conclusion • Preliminary results suggest that intraoperative aberrometry can improve results with Femtosecond laser cataract surgery • Proposed addition evaluation ▫ Included a non FSL, non ORA group ▫ Include an ORA only group