BUILDING ENVELOPE CONSULTING SERVICES CONSTRUCTION COMPLIANCE TESTING STORM RELATED ROOF DAMAGE ASSESSMENTS FORENSIC INVESTIGATIONS LITIGATION SUPPORT FM GLOBAL 1 – 52 FIELD UPLIFT TESTS ASTM E 907 FIELD TESTING UPLIFT RESISTANCE OF ADHERED MEMBRANE ROOFING SYSTEMS ASTM E 1105 STANDARD TEST METHOD FOR FIELD DETERMINATION OF WATER PENETRATION OF INSTALLED EXTERIOR WINDOWS, SKYLIGHTS, DOORS, AND CURTAIN WALLS NEGATIVE PRESSURE TESTING SIMULATING WIND UPLIFT PRESSURE TO VERIFY RESISTANCE OF LOW-SLOPE MEMBRANE ROOFS FM GLOBAL 1-52 ASTM E 907 WIND WIND ACTS A FLUID FLOWING OVER AND AROUND STANTIONARY OBJECTS WIND ~ 25 psf WIND CAUSES AND CAN CAUSEAA POSITIVE PRESSURE NEGATIVE (UPWARD) ON THE WINDWARD PRESSURE ON THE SIDE OFROOF THE OBJECT 25 psf WIND AFTER THE STORM BUR - DELAMINATION Poor Adhesion Between Insulation and Cover Board Poor Adhesion Between Cover Board and Membrane Poor Adhesion Between Deck and Insulation BUR - DELAMINATION Poor Adhesion Between Cover Board and Membrane TPO - DELAMINATION Poor Adhesion Between Insulation and Membrane TPO - DELAMINATION BUR - FASTENER FAILURE BEFORE THE STORM… NEGATIVE PRESSURE TESTING CONSTRUCTION COMPLIANCE AND RISK ASSESSMENT NEGATIVE PRESSURE TESTING NEGATIVE PRESSURE TESTING 5’ SQ Chamber Imposes an Uplift Force on the Membrane Pressure is Incrementally Increased to the Design Test Pressure Deflection of the Membrane is Measured and Compared to Performance Criteria NEGATIVE PRESSURE TESTING Fastener holding adequately at test pressure NEGATIVE PRESSURE TEST Application Acceptance of new (including re-roofed and re-covered) above-deck roofing assemblies by FM Global…in regions that are both prone to hurricanes, typhoons or tropical cyclones and where design wind speeds are at least 100 mph (FM 1-52). Field verification of adhesion of low-slope roof for the issuance of a certificate of insurability. For example WPI-8 for the Texas Department of Insurance (TDI). NEGATIVE PRESSURE TEST Application Risk Assessment – as part of the evaluation of a property this test could be used to determine probable loss at incremental pressure (Hurricane Strengths). CURTAIN WALL TESTING NEW CONSTRUCTION FORENSIC INVESTIGATIONS RISK ASSESSMENT DUE DILIGENCE CURTAIN WALL TESTING Rack Calibrated to Deliver 5 gal / sf / hr CURTAIN WALL TESTING CURTAIN WALL TESTING Pressure Differential Imposed Across System CURTAIN WALL TESTING CURTAIN WALL TESTING CURTAIN WALL TESTING CURTAIN WALL TESTING CURTAIN WALL TESTING Water Infiltration FORENSIC – COMPONENT ISOLATION The Forensic Version of the Test Allows For Isolation of Various Components to Determine Mode of Failure. FORENSIC – COMPONENT ISOLATION FORENSIC – COMPONENT ISOLATION IR Images During Test Help Indentify Path of Water Intrusion FORENSIC – COMPONENT ISOLATION IR Images During Test Help Indentify Path of Water Intrusion DESTRUCTIVE OBSERVATIONS…SOMETIMES YOU JUST NEED TO OPEN THE WALL AND SEE WHAT IS HAPPENING FORENSIC INVESTIGATIONS LITIGATION SUPPORT WATER INFILTRATION INVESTIGATIONS WATER INFILTRATION INVESTIGATIONS WATER INFILTRATION INVESTIGATIONS WATER INFILTRATION INVESTIGATIONS WATER INFILTRATION INVESTIGATIONS Remove Finish Materials WATER INFILTRATION INVESTIGATIONS Document MC of Framing WATER INFILTRATION INVESTIGATIONS Run Component Isolating Water Test to Determine Mode of Failure BUILDING ENVELOPE SURVEY NEW CONSTRUCTION LITIGATION SUPPORT FORENSIC INVESTIGATIONS RISK ASSESSMENT DUE DILIGENCE BUILDING ENVELOPE SURVEYS BUILDING ENVELOPE SURVEYS BUILDING ENVELOPE SURVEYS BUILDING ENVELOPE SURVEYS BUILDING ENVELOPE SURVEYS