Industrial Energy Management Solutions

advertisement
GE Digital Energy Multilin
Industrial Solutions for Energy Management
and Energy Efficiency
By
John S. Levine, P.E.
Levine Lectronics and Lectric, Inc.
John@L-3.com
1
GE Digital Energy Multilin
We deliver, protect, connect and control & monitor power from generation to
critical equipment to consumers; enabling safe, reliable, cleaner, more
efficient, and smarter power.
Meters and
Protection & Control
Advanced Meter Infrastructure
Automation
Communications
2
Metering Solutions
3
Basic to Advanced Facilities Metering
EPM5350
EPM9800
PQM II
EPM9000
Price
EPM6000
EPM2000
Basic Power Monitoring
 Cost-effective option
for simple power
measurements
 SCADA transducer
replacement
Power Quality & Cost Management
 Dynamic power factor
correction
 Cost allocation &
demand management
 Alarms and trending for
preventive maintenance
 Voltage disturbance
recordings
Advanced PQ Analysis
 Advanced analysis of
power disturbances via
high-speed sampling
 Power quality
compliance audit
against utility
providers
 Time-synchronized
power-flow analysis
4
Basic to Advanced Facilities Metering
Basic Power
Monitoring
Power Quality
& Cost Management
Advanced Power
Quality Analysis
 3-phase continuous
monitoring
 Measure power
factor in addition to
V,I and frequency
 Basic Power
Monitoring
requirements plus:
 Built-in logging
 Power Quality &
Cost Management
requirements plus:
 Sub-cycle transients
detection
 Flicker reporting
 IRIG-B time-sync
•
•
•
•
History (trend data)
Sequence of events
Waveform capture
Sag & Swell
 Additional power
quality metrics
 I/O options
5
Smart Load Shed Scheme
6
Smart Load Shed Scheme
• Scheme uses Multilin UR relays (F35, F60, G60, etc.)
connected via Ethernet network to calculate power at
locations throughout facility
• Analog power values are sent to master C90Plus control and
programmable logic within C90Plus determines loads to
shed based on user configuration
• C90Plus controller capable of communicating to 32 UR
relays located throughout facility
• Smart load shed scheme capable of selecting the next loads
to shed based on current profitability of the process or other
predetermined criteria
7
Example
Smart
Load
Shed
Layout
Utility Tie
Generator 2
G2
52
C90
52
SUT
CUT
52
F35
52
SA
F60
F60
52
SP1
Process 1
G1
G60
G60
52
SG2
CG2
SG1
CG1
52
Process 2
F60
52
SP3
SP2
d
Admin Offices
Generator 1
Process 3
F60
SP4
Process 4
8
Smart Load Shed - Communications Requirements
SUT
CUT
SG2
CG2
SG1
CG1
Utility Tie
Generator 2
Generator 1
Admin Offices
Process 1
Process 2
Process 3
Process 4
SA
SP1
SP2
SP3
SP4
d
Analog Power Values over IEC61850 GOOSE
Messaging using Plant LAN
9
Smart Load Shed Scheme Benefits
• C90Plus can be configured to meet numerous
configurations. It is completely programmable.
• With the addition of UR relays to your facility, the UR relays
provide:
 State of the art protection & control for your critical assets, such as
motors, generators, transformers and feeders
 Metering of your critical assets, such as motors, generators,
transformers and feeders via Plant LAN.
 Reduced downtime with modular construction
10
Intuitive Monitoring & Control
Solutions
11
12
Viewpoint Monitoring
Easy to use Monitoring and Data Recording
13
Viewpoint Monitoring
Easy to use Monitoring and Data Recording for Small to Medium Systems (50 to 150 devices)
PLUG-AND-PLAY MONITORING
Pre-configured screens for
instant monitoring
SINGLE-LINE MONITORING AND CONTROL
View Single-Line monitoring
screens in minutes
AUTOMATIC EVENT AND WAVEFORM RETRIEVAL
Effortless Data Archiving
GLOBAL COMTRADE VIEWER
View Waveforms Recorded
From your Devices
TRENDING REPORTS
Historical Record of
Monitored Data
AUTOMATIC EVENT AND WAVEFORM RETRIEVAL
Instant Alarm Notification
14
Viewpoint Monitoring
Many Devices
Supported
The following
Devices and
Firmware Versions
are supported by
Viewpoint
Monitoring
You can easily add
third party devices.
15
Viewpoint Monitoring: Plug-and-Play
How to Save Time and Costs with Viewpoint Monitoring
OVERVIEW
Operating condition of your motor
Status of your GE Multilin Relay or Meter
METERING
All metering quantities (Amps, Volts, Power, Demand)
Motor temperature monitored by the RTD’s
ALARMS
Active Alarms detected by the relay
Latched Alarms that require clearing
TRIP
Cause of the last motor trip
Pre-trip data
LEARNED
Learned motor and RTD data
Learned motor load
MAINTENANCE
Trip counters and motor Starts
Total motor running hours
16
Viewpoint Monitoring
PLUG-AND-PLAY MOTOR MONITORING
Instantly view critical data including:
• Number of Motor Starts
• Learned Motor Starting Current
• Motor Running Hours
• History of Motor Trips
• Real time power quantities
• Motor Temperature
17
Viewpoint Monitoring
PLUG-AND-PLAY FEEDER MONITORING
Instantly view critical data including:
• Breaker Status
• Accumulated Breaker Arcing Current
• Real time power quantities
(Amps, Volts, Demand, Energy)
• Synchronism data
18
Viewpoint Monitoring
PLUG-AND-PLAY TRANSFORMER MONITORING
Instantly view critical data including:
• Transformer Energization Status
• Real time power quantities
(Amps, Transformer Loading, Demand)
• Current Harmonic Analysis
• Accumulated Loss of Life
• Tap Changer Position
• Hottest Winding Temperature
19
Viewpoint Monitoring
PLUG-AND-PLAY GENERATOR MONITORING
Instantly view critical data including:
• Generator Loading
• Real time power quantities (Amps, Volts)
• Cause of Trip Data
• Generator Running Hours
• History of Generator Trips
• Generator Temperature
20
Viewpoint Monitoring
PLUG-AND-PLAY POWER QUALITY MONITORING
Instantly view critical data including:
• Power Quality and Equipment Status
• Load unbalances using real time and
maximum & minimum values
• Cost of Energy using inputs from
revenue meters
• Amount of total harmonic distortion
on the power system
21
Viewpoint Monitoring
PLUG-AND-PLAY BACKUP MONITORING
Instantly view critical data including:
• Availability of Normal and Emergency
power sources
• Status of Power Source connections
• Real time voltages and frequency
• Switch status, Timer settings, and
control Switch Position
• Stored Events and Exerciser Schedules
22
Viewpoint Monitoring
PLUG-AND-PLAY BREAKER MONITORING
Instantly view critical data including:
• Breaker Status
• Number of breaker trip operations
• Real time Current, Voltage and
Power levels
23
Viewpoint Monitoring
Single-Line Monitoring and Control
Monitor and Control all devices in your Power System
• Identify the status of all the devices in your power
system on a customized single-line monitoring screen
• Monitor the magnitude of any power quantity
measured by your metering and protection devices
• Navigate though multiple monitoring screens to view
the status of different parts of your network
• Communicate with up to 150 devices and 9000 points
Create single-line monitoring screens in minutes
• Construct system diagrams with drag and drop ease
• Contains all necessary symbols and tools required for
replicating your power system
• Includes a library of meters and Dials to graphically
represent any metered quantity
24
Viewpoint Monitoring
Automatic Event and Waveform Retrieval
Event Logging
• Automatic download of events which are stored in
a system wide Sequence of Event Record
• Devices continually polled to check for new Events
• Sort and Query system event record to view events
categorized by date, device type, timestamp, or
customized criteria
• No configuration required
Waveform Archiving
• Waveform files from GE Multilin Devices
automatically downloaded from a device and stored
on your hard drive
• Devices continually polled to check for new
Waveforms
• Diagnose waveform fault data recorded in your
power system device in a Time-based, Phasor
Quantity and Tabular view
25
Viewpoint Monitoring
Trending Reports
Historical Record of monitored data
• Trend up to 500 data points
(10 records with 50 values each)
• Records data with 1 minute resolution indefinitely
• View data in time based graphical or tabular format
Annunciator Alarming
Instant Alarm Notification
• Create alarms on any monitored analog or digital
data point
• Receive alarm warnings through Audio, Visual
or Email notification
26
Viewpoint Monitoring
Automatic synchronism of connected device’s time and date
• Check the ‘Time Download’ check
box for synchronizing your relay’s
real-time clock with your Viewpoint
Monitoring computer system.
• When this option is enabled,
Viewpoint Monitoring will perform
the time synchronization in every
12-hour interval between your
relay and your Viewpoint
Monitoring computer system.
27
Viewpoint Monitoring
Third Party Device Support
• Add any third party device that
supports Modbus RTU or Modbus TCP/IP
protocol
• Add non-GE Multilin devices in your facility
to your Viewpoint Monitoring and Control
System
• Third Party devices can be used in your:
• Single Line Diagrams
• Annunciator Panel
• Trending Reports
28
Viewpoint Monitoring
OPC Server Option
Provide the data that is being read by the relays
and meters to any third party OPC compliant
Automation or Monitoring System
• Provide up to 3000 (for 50 devices) or 9000 (for 150
devices) data points (tags) to any OPC client
• Supports the entire library of devices that comes
with Viewpoint Monitoring or add other third party
Modbus compliant devices
• Ability to provide data for any third party devices
added to the Viewpoint Monitoring database
29
ViewNodes
Remote Monitoring & Control
• The EnerVista ViewNode software allows multiple users to
remotely monitor and control existing Viewpoint Monitoring
systems.
• Multiple user accounts and security levels ensures system
information is always accessible and secure.
Key Features include:
• Remotely Access to:
One Line Diagrams
Plug-and-Play screens
Annunciator Panels
Trending reports
Sequence of Events and Waveforms
• Up to 10 ViewNodes can access a single Viewpoint
Monitoring server
• Multiple user accounts and security levels ensures secure
monitoring and control of your system
30