Introduction to TAC Products No 1 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Introduction to TAC Products TAC provides profitable building environment services for: -indoor climate, comfort, -security and use of energy with complete IT based Open Systems and services, Building IT for: -end users and property owners with own organization in defined markets and through partners all over the world. TAC is owned by Schneider Electric: 74,800 employees, sales of EUR 9.1 billion, through 13,000 sales outlets in 130 countries. No 2 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 No 3 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 TAC Xenta overview Based on the open LonWorks® communication standard TAC Xenta® 100 Application Specific Terminal Units TAC Xenta® 200 Programmable Terminal Units TAC Xenta® 300 Programmable Central Station Equipment TAC Xenta® 400 Supervisory Control and Data Management / High Density IO TAC Xenta® 500 for Internet connectivity TAC Xenta® 900 Ethernet Communications / Gateways No 4 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 100 – ASC Terminal Unit Controllers Applications Fan Coil VAV Roof Top Units / Unit Ventilator Dual Zone, H/C and Light/Sunblind control Stand-alone operation or as part of a system LonMark® approved for use in any LonWorks based systems No 5 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 200 – Programmable Terminal Units • Compact and modular design • Custom Zone applications • Smaller HVAC Applications • Programmable • LonMark® approved for use in any LonWorks based system • 3 I/O Configurations No 6 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 300 – Programmable / Expandable • Compact and modular design • Programmable • Expandable by 2 I/O modules • LonMark® approved for use in any LonWorks based system • 2 I/O Configurations No 7 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 400 – Supervisory Control & High Point Count • Used with I/O modules – becomes high point controller for sophisticated applications • High memory, millisecond sample rates • Supports high number of network variables for use as a data manager • LonMark® approved for use in any LonWorks based system No 8 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 400 – I/O Expansion Modules Products TAC Xenta 411 and 412 TAC Xenta 421 and 422 (A) TAC Xenta 451 and 452 (A) TAC Xenta 471 TAC Xenta 491 and 492 Expansion of I/O capability for Xenta 300 & 400 controllers Communicate with controller over the FTT-10 for distributed installation No 9 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 500 Series 511 – Built-in web server for small to medium size buildings over the Internet or Intranet Graphics, alarm display, time schedules, Trend log and viewer TCP/IP, 10Base-T & LONWORKS®FTT-10 527 – Built-in web server for INET system No 10 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta 900 Series 901 – Serial LonTalk Adapter 911 – Ethernet Communications Device LonTalk adapter between TAC Vista and a LonWorks network. IP Modem with dial-up functionality over the computer network. Ex. Could be used together with ISDN over a dial on demand link Serial Communication Port for proprietary system 913 – Gateway for LonWorks to BACNet and ModBus No 11 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Xenta Design & Installation Modular design Few points per unit Expandable with additional modules Installation and service friendly Terminal base with all connections Plug-in electronic unit DIN rail mounting No 12 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 TAC Vista - Modularity Workstation Webstation ScreenMate Vista Server Report Menta xBuilder No 13 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 TAC Vista Openness/Vendor independent • Windows • LonWorks • OPC • TCP/IP • Wireless • BACNET • MODBUS No 14 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 TAC Vista - Scalability • Standalone • Non-Workstation • Dial-up • LTA card • Lon Router • IP LTA • IP Router No 15 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Field: STR - wall modules Attractive, time-less and functional design ZS 100 full replacement: STR100 - STR107 S/Stat and I/Stat replacement: STR200 - STR202, STR250 Display versions for high volume TAC Xenta 100 models STR150 Easy installation Installation adapted to all markets Customizable color No 16 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Field: STR350 Modes of Operation LonMark Mode – LonMark Profile: Space Comfort Control Command Module – SNVT – TAC Xenta 100/280/300/401 – 3rd party LonWorks controllers – LNS Plug-in for Configuration Vista Classic Mode – – – – No bindings needed Connects similar to Xenta I/O module TAC Xenta 280/300/401 Reduced Functionality (Light and Sunblind Control excluded) No 17 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Field: Valves & Actuators TAC Venta valves Size DN15 – DN50 DN65 DN150 PN 16 2-way V241 V211T V212T V341 V311T V311 V231 V232 V211 V212 V222 PN 16 3-way V321 PN25 2-way No 18 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 V292 Field: Valves & Actuators Butterfly valves and actuators Input TRV-S No 19 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 721-6010-000 721-6014-000 721-6018-000 721-6022-000 721-6026-000 721-6030-000 721-6034-000 721-6038-000 721-6042-000 721-6046-000 TRV-S TRV-S TRV-S TRV-S TRV-S TRV-S TRV-S TRV-S TRV-S TRV-S 25 32 40 50 65 80 100 125 150 200 911-3010-000 911-3014-000 911-3018-000 911-3022-000 911-3026-000 Kit MB15 to TRV-S DN25-65 Kit MB15 to TRV-S DN80-100 Kit MB30 to TRV-S DN25-65 Kit MB30 to TRV-S DN80-125 Kit MB30 to TRV-S DN150-200 A A A A A B B A B C D E MB15B MB15A MB30B MB30A 3-point 0...10 V 3-point 0...10 V Close off (kP) 1000 Close off (kP) 1000 Close off (kP) 1000 Close off (kP) 1000 1000 1000 1000 1000 1000 1000 1600 1600 1000 1000 1600 1600 700 700 1600 1600 400 400 1000 1000 200 200 1000 1000 600 600 500 500 300 300 C C C C C D D D E E Field: Fluid Control Units (FCU) MZ18L MZ18A MZ18B MZ10T Zone FCU LON VZ22 VZ32 VZ42 No 20 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 0 – 10 V 3-point 24V On/off 24V;230V Field: Damper actuator and sensors No 21 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 No 22 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Security Devices overview Communication controller Netplus Router Network controller I/Site 7798 LIU 7790 DPU 7910 DPU 7920 DIU 7930 DIO 7940 No 23 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Security controller • OPEN SQL Database • Peer to Peer Communication • Access Initiated Control • Anti Passback • Independent Alarm Monitoring • User defined Card format • Real Time Graphics No 24 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 On The Horizon TAC’s Technology Road Map No 25 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Summary of Trends Plug & Play Wireless Automatic Engineering Openness IP No 26 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Standards System Vision Summary • Pushbutton Engineering 1 – – Ready-made Applications Common Engineering Database & Document Management – Powerful Tools – Quick and easy to engineer • Building Networks – 2 – – – – IP-based Building Networks for Technical Installations High IT Security Profile More than one Open Protocol Increasingly Wireless To be loved by IT People No 27 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 • Various Viewfinders – 3 Foresee the use of many alternative Viewing Devices – Functionality adapted to different User-groups – Highlight Ease-of-use – Put the user in focus • Design Considerations 4 – – – Built on Open Industry Standards True IP Foundation Distributed Servers in co-operation – Powerful HW/SW platforms – Flexible and modular by design Next Generation TAC System Architecture Engineering Studio Various Viewfinders Central Services Building Operation Services • Customer communication platform • Automatic services • Expert services IP 3rd Party Systems IT Services Next Generation TAC System • Portal • Program update center • Mail & SMS • DNS service • System hosting No 28 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Current systems Product Road Map Migration from TAC Vista and I/NET to a New System Based on the Vision TAC Vista Development Next Generation TAC System I-talk Central services I/NET Development 2003 No 29 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 2007 1st Major Milestone: Vista V architecture Web browser Vista Workstation IP ( HTTP(S), Web services) Web browser Vista Server DB Vista WebStation IP (LonWorks EIA-852, BACnet/IP, Modbus TCP, HTTP(S), Web services Xenta 511 Xenta 511 (distributed server) Xenta 527 (distributed server) LonWorks LonWorks Xenta 5xx (distributed server) Modbus IP controller I/NET Host LAN LonWorks NPR Xenta 301 Xenta 301 Modbus device Xenta 301 Lon device Lon device Modbus device Lon device I/NET Sub LAN Xenta 401 Xenta 401 Modbus device Xenta 401 I/NET Sub LAN Lon device Lon device No 30 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Modbus device Lon device I/NET Controller LAN I/NET Sub LAN 3-5 Years Product Road Map No 31 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004 Thank You No 32 Copyright © TAC CONTROLS ASIA PTE. LTD. 2004