TAC Vista

advertisement
Introduction to TAC Products
No 1
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Introduction to TAC Products
TAC provides profitable building
environment services for:
-indoor climate, comfort,
-security and use of energy
with complete IT based Open Systems
and services, Building IT for:
-end users and property owners
with own organization in defined markets
and through partners all over the world.
TAC is owned by Schneider Electric: 74,800 employees,
sales of EUR 9.1 billion, through 13,000 sales outlets in 130 countries.
No 2
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
No 3
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
TAC Xenta overview
 Based on the open LonWorks® communication standard
 TAC Xenta® 100 Application Specific Terminal Units
 TAC Xenta® 200 Programmable Terminal Units
 TAC Xenta® 300 Programmable Central Station Equipment
 TAC Xenta® 400 Supervisory Control and Data Management / High
Density IO
 TAC Xenta® 500 for Internet connectivity
 TAC Xenta® 900 Ethernet Communications / Gateways
No 4
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 100 –
ASC Terminal Unit Controllers
Applications
Fan Coil
VAV
Roof Top Units / Unit
Ventilator
Dual Zone, H/C and
Light/Sunblind control
Stand-alone operation or as part of
a system
LonMark® approved for use in any
LonWorks based systems
No 5
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 200 –
Programmable Terminal Units
• Compact and modular design
• Custom Zone applications
• Smaller HVAC Applications
• Programmable
• LonMark® approved for use in any
LonWorks based system
• 3 I/O Configurations
No 6
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 300 –
Programmable / Expandable
• Compact and modular design
• Programmable
• Expandable by 2 I/O modules
• LonMark® approved for use in any
LonWorks based system
• 2 I/O Configurations
No 7
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 400 –
Supervisory Control & High Point Count
• Used with I/O modules –
becomes high point controller for
sophisticated applications
• High memory, millisecond
sample rates
• Supports high number of network
variables for use as a data
manager
• LonMark® approved for use in
any LonWorks based system
No 8
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 400 – I/O Expansion Modules
Products
TAC Xenta 411 and 412
TAC Xenta 421 and 422 (A)
TAC Xenta 451 and 452 (A)
TAC Xenta 471
TAC Xenta 491 and 492
Expansion of I/O capability for Xenta
300 & 400 controllers
Communicate with controller over the
FTT-10 for distributed installation
No 9
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 500 Series
511 – Built-in web server for small to medium size buildings
over the Internet or Intranet
Graphics, alarm display, time schedules, Trend log and viewer
TCP/IP, 10Base-T & LONWORKS®FTT-10
527 – Built-in web server for INET system
No 10
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta 900 Series
901 – Serial LonTalk Adapter
911 – Ethernet Communications Device
LonTalk adapter between TAC Vista and a
LonWorks network.
IP Modem with dial-up functionality over the
computer network. Ex. Could be used together
with ISDN over a dial on demand link
Serial Communication Port for proprietary system
913 – Gateway for LonWorks to BACNet and ModBus
No 11
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Xenta Design & Installation
Modular design
Few points per unit
Expandable with additional
modules
Installation and service friendly
Terminal base with all
connections
Plug-in electronic unit
DIN rail mounting
No 12
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
TAC Vista - Modularity
Workstation
Webstation
ScreenMate
Vista Server
Report
Menta
xBuilder
No 13
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
TAC Vista
Openness/Vendor independent
• Windows
• LonWorks
• OPC
• TCP/IP
• Wireless
• BACNET
• MODBUS
No 14
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
TAC Vista - Scalability
• Standalone
• Non-Workstation
• Dial-up
• LTA card
• Lon Router
• IP LTA
• IP Router
No 15
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Field: STR - wall modules
 Attractive, time-less and
functional design
 ZS 100 full replacement:
STR100 - STR107
 S/Stat and I/Stat replacement:
STR200 - STR202, STR250
 Display versions for high
volume TAC Xenta 100 models
STR150
 Easy installation
 Installation adapted to all
markets
 Customizable color
No 16
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Field: STR350 Modes of Operation
 LonMark Mode
– LonMark Profile:
Space Comfort Control Command Module
– SNVT
– TAC Xenta 100/280/300/401
– 3rd party LonWorks controllers
– LNS Plug-in for Configuration
 Vista Classic Mode
–
–
–
–
No bindings needed
Connects similar to Xenta I/O module
TAC Xenta 280/300/401
Reduced Functionality
(Light and Sunblind Control excluded)
No 17
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Field: Valves & Actuators
TAC Venta valves
Size DN15 – DN50
DN65
DN150
PN 16
2-way
V241
V211T
V212T
V341
V311T
V311
V231
V232
V211
V212
V222
PN 16
3-way
V321
PN25
2-way
No 18
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
V292
Field: Valves & Actuators
 Butterfly valves and actuators
Input
TRV-S
No 19
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
721-6010-000
721-6014-000
721-6018-000
721-6022-000
721-6026-000
721-6030-000
721-6034-000
721-6038-000
721-6042-000
721-6046-000
TRV-S
TRV-S
TRV-S
TRV-S
TRV-S
TRV-S
TRV-S
TRV-S
TRV-S
TRV-S
25
32
40
50
65
80
100
125
150
200
911-3010-000
911-3014-000
911-3018-000
911-3022-000
911-3026-000
Kit MB15 to TRV-S DN25-65
Kit MB15 to TRV-S DN80-100
Kit MB30 to TRV-S DN25-65
Kit MB30 to TRV-S DN80-125
Kit MB30 to TRV-S DN150-200
A
A
A
A
A
B
B
A
B
C
D
E
MB15B
MB15A
MB30B
MB30A
3-point
0...10 V
3-point
0...10 V
Close off
(kP)
1000
Close off
(kP)
1000
Close off
(kP)
1000
Close off
(kP)
1000
1000
1000
1000
1000
1000
1000
1600
1600
1000
1000
1600
1600
700
700
1600
1600
400
400
1000
1000
200
200
1000
1000
600
600
500
500
300
300
C
C
C
C
C
D
D
D
E
E
Field: Fluid Control Units (FCU)
MZ18L
MZ18A
MZ18B
MZ10T
 Zone FCU
LON
VZ22
VZ32
VZ42
No 20
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
0 – 10 V
3-point 24V
On/off 24V;230V
Field: Damper actuator and sensors
No 21
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
No 22
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Security Devices overview
Communication controller
Netplus Router
Network controller
I/Site 7798
LIU 7790
DPU 7910
DPU 7920
DIU 7930
DIO 7940
No 23
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Security controller
• OPEN SQL Database
• Peer to Peer Communication
• Access Initiated Control
• Anti Passback
• Independent Alarm Monitoring
• User defined Card format
• Real Time Graphics
No 24
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
On The Horizon
TAC’s Technology Road Map
No 25
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Summary of Trends
Plug & Play
Wireless
Automatic
Engineering
Openness
IP
No 26
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Standards
System Vision Summary
• Pushbutton Engineering
1
–
–
Ready-made Applications
Common Engineering Database
& Document Management
– Powerful Tools
– Quick and easy to engineer
• Building Networks
–
2
–
–
–
–
IP-based Building Networks for
Technical Installations
High IT Security Profile
More than one Open Protocol
Increasingly Wireless
To be loved by IT People
No 27
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
• Various Viewfinders
–
3
Foresee the use of many
alternative Viewing Devices
– Functionality adapted to different
User-groups
– Highlight Ease-of-use
– Put the user in focus
• Design Considerations
4
–
–
–
Built on Open Industry Standards
True IP Foundation
Distributed Servers in
co-operation
– Powerful HW/SW platforms
– Flexible and modular by design
Next Generation TAC System Architecture
Engineering Studio
Various Viewfinders
Central Services
Building Operation Services
• Customer communication platform
• Automatic services
• Expert services
IP
3rd Party Systems
IT Services
Next Generation TAC System
• Portal
• Program update center
• Mail & SMS
• DNS service
• System hosting
No 28
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Current systems
Product Road Map
Migration from TAC Vista and I/NET to
a New System Based on the Vision
TAC Vista Development
Next Generation TAC System
I-talk Central services
I/NET Development
2003
No 29
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
2007
1st Major Milestone: Vista V architecture
Web
browser
Vista
Workstation
IP ( HTTP(S), Web services)
Web
browser
Vista
Server
DB
Vista
WebStation
IP (LonWorks EIA-852, BACnet/IP,
Modbus TCP, HTTP(S), Web services
Xenta 511
Xenta 511
(distributed server)
Xenta 527
(distributed server)
LonWorks
LonWorks
Xenta 5xx
(distributed server)
Modbus
IP controller
I/NET Host LAN
LonWorks
NPR
Xenta 301
Xenta 301
Modbus device
Xenta 301
Lon device
Lon device
Modbus device
Lon device
I/NET Sub LAN
Xenta 401
Xenta 401
Modbus device
Xenta 401
I/NET Sub LAN
Lon device
Lon device
No 30
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Modbus device
Lon device
I/NET Controller LAN
I/NET Sub LAN
3-5 Years Product Road Map
No 31
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Thank You
No 32
Copyright © TAC CONTROLS ASIA PTE. LTD. 2004
Download