1. Production Capacity HYUNDAI 1) Annual Production Capacity : 28,000MVA 2) Maximum Capacity : up to 800MVA(3 phase) 3) Maximum Voltage : up to 765kV, 2050 BIL 4) Factory Space : 16,800m² 5) Manpower for Transformer factory - 55 Engineers - 340 Skilled Workers 2 2. Production Range HYUNDAI 1) Power Transformer 2) Distribution Transformer 3) Cast resin Transformer 4) Special Purpose Transformer Rectifier Transformer Furnace Transformer Dry type Transformer Shunt Reactor Mobile Transformer 3 3. Quality Assurance (ISO 9001) HYUNDAI 1) Original Date of Issue : July of 1989 2) Registered Parts of Quality Assurance Transformer Design and Development Production and Testing Installation and Service 4 4. Applicable Standard HYUNDAI 1) IEC 76 (For Europe and Asia) 2) ANSI C57.12.00 (For America) 3) CAN/CSA-C88-M90 (For Canada) 4) AS 2374 (For Australia) 5) ES 140 (For Korea) 5 5. Short Circuit Test HYUNDAI 1) Major Performance Record of Short Circuit Test No. Specification of Transformer Test Date Test of Tap Change Customer 1 Generating Transformer 3PH 6/64/85/106/119MVA 230/14.8kV YNd1 Sept. 1995 N.L.T.C PUD in USA 2 Power Transformer 3PH 45/60MVA 154/23kV Ynyno(d) Nov. 1989 O.L.T.C KEPCO in Korea 3 Power Transformer 3PH 35/44MVA 154/23kV YNd1 Nov. 1986 O.L.T.C In-Chon Iron & Steel in Korea 4 Distribution Transformer 3PH 10MVA 22/6.6kV Ynynod(d) Dec. 1986 O.L.T.C PUB in Singapore 5 Power Transformer 3PH 20/26MVA 132/11.5kV Dyn11 Dec. 1986 O.L.T.C WAPDA in Parkistan 6 5. Short Circuit Test HYUNDAI 2) Detailed Explanation for the Short Circuit Test Performed to the 230kV Transformers for Rocky Reach Project Customer : Public Utility District No.1 of Chelan County in U.S.A Project Transformer Rating : Replacement for Rocky Reach Dam Transformer 3phase 60Hz 119MVA 14.8/230kV Step-up Transformer Basic Impulse Level on H.V Side : 900kV Standard : ANSI C57.12.00 Tested and Certified by Korea Electrotechnology Research Institute 7 Picture of Short Circuit Test HYUNDAI 8 6. Development of Transformer HYUNDAI 1) 765kV Transformer 1PH 60Hz 2 x 333.3MVA 765/345kV OLTC type Auto transformer (Bil : 2050kV) : 1998 Developed 1PH 60Hz 204MVA 20.9/765kV NLTC type Step-up transformer (Bil : 2050kV) : 1999 Developed 1PH 60Hz 370MVA 765/345/23kV NLTC type Auto transformer (Bil : 2050kV) : 1999 Developed 2) Gas Insulated Transformer 1PH 60Hz 20MVA 154/23kV OLTC Type Transformer (Under Development) 9 6. Development of Transformer HYUNDAI 3) Mobile Transformer (Developed) 3PH 60Hz 40MVA 154/23kV (1996) "H" Class insulation (95C temp. rise) Comparison of "A" and "H" class insulation Insulation No Load Loss Load Loss Weight “A” Class 31 kW 241 kW 35 TON “H” class 23 kW 434kW 25 TON Remark 74% 180% 71% Transportation with trailer Weight : 39.4 Ton Size(m) : L8.6 x W2.9 x H3.9 10 Picture of 154kV 40MVA Mobile Transformer-Using H Class Insulation (NOMAX Paper) HYUNDAI 11 7. Major International Clients and Performances HYUNDAI 1) North America Country U.S.A Client Alumnium Company of America Los Angeles Department of Water and Power Chelan Country Black & Veatch General Electric Company Baltimore Gas & Electric CRS Sirrine Engineers Zurn Nepco Westinghouse Florida Power Corporation Colorado River Commission of Nevada Sacramento Municipal Utility District Duke Fluor Daniel Babcock & Wilcox Engineering Lower Colorado River Authority Puget Sound Energy National Electrical System Inc. City of Tacoma New York Power Authority Rating of Transformer 161/13.8kV, 93MVA 34.5/5.04kV, 16MVA 230/14.8kV, 119MVA 230/15.75kV, 315MVA 138/13.8kV, 125MVA 13.8/2 X 3.9kV, 20MVA 69/13.8KkV, 90MVA 132/11.5kV, 90MVA 138/13.8kV, 150MVA 16/230kV, 235MVA 230/69kV, 200MVA 230/69/13.8kV, 200MVA 115/11kV, 93MVA 138/15.5kV, 160MVA 138/22.8kV, 490MVA 230/117.8kV, 325MVA 115/13.2kV, 115MVA 115/13.8kV, 56MVA 230/13.2kV, 86MVA 12 7. Major International Clients and Performances HYUNDAI 2) South America Country Client Rating of Transformer 230/34.5kV, 50MVA Interconexion Electrical S.A 500/230/34.5kV, 150MVA Colombia EPM 230/115/46kV, 90MVA ESSA 115/34.5/13.8kV, 40MVA Trinidad & Tobago Trinidad & Tobogo Electricity Commission (TTEC) 33/12kV, 6MVA Panama CELMEC 115/13.8kV, 50MVA Chile Chilectra 230/110/13.2kV, 130MVA Peru Proyecto Ampliacion de LA S. E. 220/60/10kV, 50MVA Guatemala JBV Guatemala, LCC 230/13.8kV, 150MVA Venezuela ENELVEN 200/115/13.8kV, 200MVA Puerto Rico Brazil Abengoa CERJ 115/2 X 13.8kV, 300MVA 138/13.8kV, 33.3MVA 13 7. Major International Clients and Performances HYUNDAI 3) Asia Country Client Rating of Transformer Japan Tokyo Electric Power Company 66/6.9kV, 20MVA Singapore Public Utilities Board (PUB) 22/6.6kV, 10MVA Tenaga Nasional Bhd. (TNB) 275/132kV, 240MVA Sarawak Electricity Supply Corp. (SESCO) 275/230kV, 250MVA Sabah Electricity Board (SEB) 275/132kV, 180MVA Perusahaan Umum Listrik Negara (PLN) 150/20kV, 100MVA National Power Corp (NPC) 230/115/13.8kV, 300MVA Manila Electric Company (MERALCO) 110/34.5/13.8kV, 83.3MVA Electricity of Vietnam (EVN) 230/121/22kV, 63MVA Vietnam POSCO Steel Co. 110/6.6kV, 20MVA Bangladesh Power Development Board (BPDB) 240/140kV, 150MVA Malaysia Indonesia Philippines Vietnam Bangladesh 14 7. Major International Clients and Performances HYUNDAI 3) Asia Country Client Rating of Transformer Electricity Generating Authority of Thailand (EGAT) 115/34.5/11kV, 50MVA Metropolitan Electricity Authority (MEA) 60/11.5kV, 60MVA Provincial Electricity Authority (PEA) 115/23.1kV, 40MVA Myanmar Electric Power Enterprise (MEPE) 132/33/11kV, 30MVA Water and Power Development Authority (WAPDA) 230/11kV, 125MVA Karachi Electricity Supply Corporation (KESC) 132/11kV, 40MVA D. G Khan Cement Company 132/6.3kV, 20/26MVA Oil and Natural Gas Commission (ONGC) 6.6/0.433kV Thailand Myanmar Parkistan India 2000KVA (Cast Resin Type) Srilanka Ceylon Electricity Board (CEB) 132/33kV, 31.5MVA 15 7. Major International Clients and Performances HYUNDAI 4) Middle East Country Client Rating of Transformer Electricity Corporation 132/33kV, 60MVA SCECO-Central 132/13.8kV, 100MVA SCECO-East 230/115/34.5kV, 400MVA Tabouk Electricity Company 132/13.8kV, 100MVA Arabian American Oil Company 66/13.8kV, 67MVA Iraq State Organization of Electricity (SOE) 400/138.6/11kV, 250MVA Yemen Yemen General Electricity Corp. (YGEC) 132/33kV, 25MVA Lebanon Council for Development & Reconstruction 66/20-11kV, 40MVA Dubai Electricity Company 33/11kV, 15MVA Water and Electricity Department 11/0.433kV, 1500KVA (Cast Resin Type) Oman Ministry of Electricity and Water 33/11kV, 20MVA Turkey Turkiye Electric Kurumu Shunt Reactor 154kV, 5MVAR Saudi Arabia U.A.E 16 7. Major International Clients and Performances HYUNDAI 5) Oceania and Canada Country Australia New Zealand Papua New Guniea Canada Client Rating of Transformer Pacific Power (The Electricity Commission of New Sourth Wales) Power Link (Queensland Electricity Commission) BHP Engineering Pty Ltd. Shortland County Council New Zealand Aluminium Smelter Ltd. (NZAS) The Electricity Commission of P.N.G 132/11kV, 20MVA 132/69/11kV, 20MVA 230/34.5kV, 80/120MVA 132/66/11kV, 120MVA 66/13.8kV, 67MVA 220/11kV, 50MVA 132/66kV, 20MVA British Columbia Hydro & Power Authority Richmond Hill Hydro Manitoba Hydro Alberta Power Ltd. Howe Sound Pulp & Paper Ltd. Yukon Electrical Company 512.5/242/25.2kV, 500MVA 212.5/2 X 28kV, 125MVA 114.3/2 X 12.47kV, 50MVA 144/25kV, 50MVA 230/13.8kV, 62MVA 138/13.8kV, 40MVA Stone & Webster Canada Ltd. Transalta Vtilities Agra Monenco/ Aurora Mine Saskatchewan Power Corporation 243/2 X 13.8kV, 171MVA 260/72kV, 224MVA 260/72kV, 116.2MVA 128/24.9kV, 29.8MVA 17 7. Major International Clients and Performances HYUNDAI 6) Europe Country Client Rating of Transformer Switzerland ABB Power Generation Ltd. 220/21kV, 420MVA Germany Siemens AG 132/6.9kV, 40/45MVA Denmark Johs Gran-Hassen Product Ltd. 220/60/10kV, 40/50MVA 7) Africa Country Client Rating of Transformer Egyptian Electricity Authority (EEA) 21/220kV, 395MVA Arco Steel 220/22.5kV, 80MVA Ethiopia Ethiopian Electric Light and Power Authority (ELPA) 132/15kV, 22MVA Libya Heavy Industries Secretariat Tripoil Socialist People’s Libyan Arab Jamshebreya 11/225kV, 105MVA Egypt 18 8. Major Production Facilities HYUNDAI 1) Over-Head Crane (300 TON x Span 38m) 2) Vacuum Vaporization Facility (L 13m x W 4.8m x H 6.6m) 3) Air - Cleaning Facility (L 45m x W 40m x H 7m) 4) Oil Filtering Machine (8,00 litter / hour) 5) Motorized Transporter for Test (400 TON x 2EA) 6) Core Binding Machine (40 TON x W 8m) 7) Core Lamination Table (120TON) 19 9. Major Testing Facilities HYUNDAI 1) Impulse Generator System ( 400KV / 600KJ ) 2) Oscillation Lightning Impulse Test System (1,800KV / 90KJ ) 3) AC Series Resonant Voltage Test System (1,200KV / 4,800KVA ) 4) AC Power Generator System ( 23MVA x 2sets ) 5) AC Power Generator System ( 23MVA x 2sets ) 6) Condenser Bank ( 158KV, 225MVAR ) 7) Transformer Loss Measuring System (200KV / 4,000A ) 20 10. Major Manufacturing Process HYUNDAI 1) Winding Works 21 10. Major Manufacturing Process HYUNDAI 2) Core lamination 22 10. Major Manufacturing Process HYUNDAI 3) View of Core Structure (After Completion of Core Lamination) 23 10. Major Manufacturing Process HYUNDAI 4) Coil Insertion Works 24 10. Major Manufacturing Process HYUNDAI 5) View of Core and Coil Assembly Works 25 10. Major Manufacturing Process HYUNDAI 6) Drying Works in Vacuum Vaporization Facility 26 10. Major Manufacturing Process HYUNDAI 7) Completion of Core & Coil Assembly 27 10. Major Manufacturing Process HYUNDAI 8) Factory Test 28