buwatec bv

advertisement
BUWATEC BV
BUWAtank
BUWATEC delivers complete
BUWAtank systems for the
storage of water and other liquids.
BUWAtank systems are the only
ones certified with the German
Prufbescheid.
BUWAtank systems are
characterised by their large
assortment, durable, fast and easy
assembly and a wide range of
applications.
BUWATEC BV
Prefab tank storage systems
BUWAtank
BUWA products
BUWAtank
BUWAtank
BUWAliner
BUWAcover
BUWAroof
BUWAtop
AIRtop
BUWAbase
BUWAhouse
Corrugated metal tanks
Tank liners and accessories
Anti algae tank covers
Anti algae tank span roof for outdoor
Metal tank roof
PVC tank roof (air pressure)
Metal tank base
Housing concept for slums and disaster areas
Selling points
BUWAtank
Advantages
Arguments
Longer lifetime (durable)
Duplex protection system (galvanised layer + coating layer (Plastisol or Polyurethane)
High tensile strength
Steel quality S 280 GD (DIN EN 10147), less weight per panel, easy to handle
High quality
Yearly checked by German Ministry of Construction
High strength of BUWAtank
Strength calculation based on ENV 1993 (German standards), on request European DIN
EN standard
Strength calculation program available
Clarify tank strength easily for the costumer convinces
Bolt sets with special alloy called “Zinc rolyte”
High corrosion resistance and very fast and easy to install (saving many hours)
Bolt set size M12
Easy to handle by hand, less bolt sets per panel (saving many hours)
Bolt position in corrugation
English manufacturers use wrong position of bolt sets (on top inside the tank), damaging
of liner
Seal packing
Provide white corrosion from the beginning.
Tank information
Stickers on each package; panel thickness, type, year of build, tank size.
Installation instructions
Installation drawing for all products without text, clarify in depended of language
Technical information of all products available
Supporting sales- and marketing managers to be successful in tank business
Innovation
Frequently design of new efficient products, practical solutions and logistic improvements
Buwatec, supplier of total storage systems
Optimize storage systems by technical and practical solutions, integration of knowledge,
production facilities and experience for innovation
BUWAtank applications
BUWAtank
Galvanising process
BUWAtank
Coil up unit
Zinc dipped
Oven
Cooling
Uncoil unit
Accumulator
Accumulator
Tank package
BUWAtank
 All panel ends sealed with foil
 Each tank has a packing list and
installation instructions
 Each panel has a sticker
mentioning the panel thickness
 Last panel has a sticker with tank
information
Panel information
BUWAtank
 Sizes standard
305 x 82 cm or
293 x 82 cm
 Panel thickness / weight
0,8 mm 17,3 kg
1,0 mm 21,9 kg
1,2 mm 26,3 kg
1,4 mm 30,6 kg
1,6 mm 35,0 kg
1,8 mm 39,4 kg
2,0 mm 43,8 kg ***
 *** three bolt holes
BUWAtank base
BUWAtank
 Ground needs to have high stability
 Excavated tank needs a minimum
depth of 0,5 meter
 Sand layer minimum of 10 cm
 Ring of concrete slabs 30/30 or
60/40
 Before installation: take care of the
lining material inside the tank
Advantages of duplex system
with Plastisol 200 coating
BUWAtank
 Manufactured in steelwork under
certificates and European standards
 On both sides of the panels
 Layer thickness Plastisol 200 µm
 Excellent results European DIN test
 Long duration (25 – 30 year)
 Less installation costs
 Good looking and professional
performance
BUWAliner types
BUWAtank
PVC Liner


normal and drinking water – KIWA certificate – wall thickness 0,5 mm
drain and wastewater - good chemical properties – wall thickness 0,5 mm
PVCPLUS Liner


normal and drinking water – higher UV properties – wall thickness 0,5 mm
manure storage – wall thickness 1,0 mm
EX Liner

drain and waste water – high UV and good chemical properties - wall
thickness 0,5 mm
Installation BUWAtank
systems
Fast and easy
With selected tools more convenience
Bolt sets with special alloy
called “Zincrolyte”
BUWAtank




High quality zinc - cobalt alloy
Layer thickness 15 µm, still flat skin
High corrosion resistance.
Better fixing, less installation costs
installation
 High ductility (mechanical strength)
 Recognized by special colour
Installation instructions for
BUWAtank
BUWAtank

Leave space around for tank inspections

Install the panels on the base system

Upper ring covers lowest ring on the
outside

Do not install the panel rings in one
vertical line

Complete tank is installed by hand

After finishing, all bolt sets need to be
fixed by force of min 20 Nm
Installation of the BUWAliner
BUWAtank

Take away all sharp elements

Equalise the sand bottom or clean the
concrete floor

Install the bottom insulation blanket (500
gr/m2) if concrete floor has been used

Install the wall insulation blanket (300
gr/m2) and fix it with plastic strips and
tie–raps

Install the liner by using clamps

Tighten the liner through the ratchet
buckles
Installing conical outlets
BUWAtank
 Pull the outlet on the pipe and cut
the material above the pipe
 Push the outlet down
 Use tape 1 for first tightening
 Use tape 2 for final tightening
BUWAtop metal tank roof
BUWAtank







Strong
Durable
Maintenance free
Easy to install
New uses for existing tanks
Deliverable up to 10,96 meter
Variety of accessories such as
inspection doors, ladders and
outlets
BUWAtop metal tank roof
BUWAtank
BUWAroof anti algae span roof
BUWAtank
 Span roof for outdoor application
 Against algae growth and pollution
of water
 Available up to Ø 22,76 meter
 Short assembly time
 Less maintenance
 Overflow system integrated into
the column
 System developed for sand bed,
concrete floors and existing tanks
BUWAroof anti algae span roof
BUWAtank
BUWAtank
A perfect product from The Netherlands
Download