Power Point

advertisement
GroundMed DAQ/DMS Training
Coimbra
6-12-2011
Andre Quintino Duarte
Anibal T. de Almeida
Joao Fong
Summary
1. DAQ - Data Acquisition System
1.1. Hardware Installation
1.1.1. Devices’ Assemblage
1.1.2. Power Connections
1.1.3. Communication Connections
1.1.4. Sensors Connections
1.2. Software Installation
1.2.1. Software Configuration
1.2.2. Measuring Utility
2. DMS - Data Management System (NEW)
3. Further Development in Coimbra
4. Questions and Answers
5. Coimbra GroundMed facility visit
Info
All information available at:
www.isr.uc.pt/~groundmed
Info
All information available at:
www.isr.uc.pt/~groundmed
1. DAQ - Data Acquisition System
1. DAQ - Data Acquisition System
National Instruments cRIO 9074
1. DAQ - Data Acquisition System
National Instruments cRIO 9074
NI 9217
NI 9871
NI 9219
1. DAQ - Data Acquisition System
DAQ
1. DAQ - Data Acquisition System
DAQ
Brunata Thermal Meters
Pyranometer
Carlo Gavazzi Meters
Humidity Sensor
Indoor/Outdoor
Temperature Sensors
1. DAQ - Data Acquisition System
D
DAQ
A
System
Q
1. DAQ - Data Acquisition System
Septemes les
DAQ
Vallons,
System
France
Oradea,
Romenia
DAQ
System
Coimbra, DAQ
Portugal
System
Benedikt, DAQ
Slovenia
System
Valencia, DAQ
Spain
System
Barcelona, DAQ
Spain System
Padova,
DAQ
Italy
System
DAQ
Athens,
Greece System
Internet
Internet
Internet
Internet
Internet
Internet
Internet
Internet
DMS
Serve
r
Ground
Med
WebSit
e
1.1. Hardware Installation
1.1.1. Device’s Assemblage
1.1. Hardware Installation
1.1.1. Device’s Assemblage
Coimbra
1.1. Hardware Installation
1.1.1. Device’s Assemblage
Barcelona
1.1. Hardware Installation
1.1.2. Power Connections
1.1. Hardware Installation
1.1.3. Communication Connections
1.1. Hardware Installation
1.1.3. Communication Connections
Important:
- Create an RS-485 network;
- Use shield cable with 2 twisted pairs;
- Connect shield to ground;
- Connect a 120Ω resistor on the edges of the
network;
- All the devices on the network must have
different addresses;
- The order is not important.
1.1. Hardware Installation
1.1.3. Communication Connections
1.1. Hardware Installation
1.1.4. Sensors Connections
1.1. Hardware Installation
1.1.4. Sensors Connections
Sensors:
- Indoor Temperature Sensor;
- Outdoor Temperature Sensor;
- Pyranometer;
- 2x Brunata (Flow Sensor and 2 Temperature
Sensors each);
- Current Transformers;
- Humidity Sensor (Optional).
1.1. Hardware Installation
1.1.4. Sensors Connections
1.1. Hardware Installation
1.1.4. Sensors Connections
Important:
- Don’t mix Brunata Temperature Sensors;
Brunata Display Unit
Temperature Probes
1.1. Hardware Installation
1.1.4. Sensors Connections
Important:
- Don’t mix Brunata flow sensors;
Flow sensor
Brunata Volume Meter
1.1. Hardware Installation
1.1.4. Sensors Connections
Important:
- Each Brunata Display Unit has one and only
one Volume Meter.
Brunata Display Unit
Brunata Volume Meter
1.1. Hardware Installation
1.1.4. Sensors Connections
1.2. Software Installation
1.2. Software Installation
Download and Install in this order:
1. NI cRIO Drivers (about
1600MB)http://joule.ni.com:80/nidu/cds/view/p/id/2411/lang/e
n;
2. RTAD Application Installer (about 10MB)
http://zone.ni.com/devzone/cda/epd/p/id/5986;3. Asynchronous
Message Communication (AMC) reference library (about 6MB)
(Not required anymore)
http://zone.ni.com/devzone/cda/epd/p/id/6091;4. Reference
Library for Reading cRIO System Configuration Information
(about 6MB) (Not required
anymore)http://zone.ni.com/devzone/cda/epd/p/id/1717;5.
GroundMed software from ISR available at:
www.isr.uc.pt/~groundmed;6. GroundMed Configuration Utility;7.
GroundMed Measurement Utility.
1.2. Software Installation
1.2.1. Software Configuration
1.2. Software Installation
1.2.1. Software Configuration
Set cRIO Time Zone, Time & Date:
1. Load MAX (Measurement & Automation) on the computer;2.
Click on Remote Systems, then the cRIO module available;3. On
the right size, click below on Time Settings;4. Set your Time
Zone, Date and Time;5. Click above on Save.
1.2. Software Installation
1.2.1. Software Configuration
Demonstration
1.2. Software Installation
1.2.1. Software Configuration
Run RT Application Deployment:
Your cRIO
Software
to install
1) Press Settings under “Application Images”;
2) Browse to load the GroundMed downloaded image;
3) Press “Deploy”.
1.2. Software Installation
1.2.1. Software Configuration
Demonstration
1.2. Software Installation
1.2.1. Software Configuration
- 8 different demonstration sites
Does this means 8 different software versions?
1.2. Software Installation
1.2.1. Software Configuration
1.2. Software Installation
1.2.1. Software Configuration
1.2. Software Installation
1.2.1. Software Configuration
1.2. Software Installation
1.2.2. Measuring Utility
1.2. Software Installation
1.2.2. Measuring Utility
1.2. Software Installation
Demonstration
3. Further Development in Coimbra
3. Further Development in Coimbra
3. Further Development in Coimbra
NI 9472
Finder Relay
20.21.9.024.4000
- 8 Sourcing Digital Outputs; - 24V Coil Voltage;
- 6 to 30V range.
- 250V AC Rated Voltag
3. Further Development in Coimbra
4. Questions and Answers
5. Coimbra GroundMed facility visit
5. Coimbra GroundMed facility visit
Thank You
Andre Quintino Duarte
Anibal T. de Almeida
Joao Fong