BACKGROUND
Manned sites
• Site fully dependent on attendant and he has to be present in
there all the time.
• Untrained and uneducated site attendant cannot maintain site
record properly.
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
• Round the clock deployment of man power. Expensive.
• Traditionally, manned sites account for more fuel pilferage than
unmanned sites.
Tuesday, April 07, 2015
2
NEED FOR HUMAN INTERVENTION???
WORK EXPECTED TO BE PERFORMED BY SITE ATTENDANT
2. Starting/ stopping of the DG set in case of power failure and auto
start up failure and making entries in the log book.
3. Switching on and switching off of AC’s.
4. Cleaning of power plant, DG battery, firefighting equipment, other
equipment at site
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
1. Refueling of diesel in DG sets and maintaining log book of
diesel refueling.
5. Answering of telephone, noting of complaints and passing
information immediately to specified competent authority.
Tuesday, April 07, 2015
3
NEED FOR HUMAN INTERVENTION???
WORK EXPECTED TO BE PERFORMED BY SITE ATTENDANT
7. Keeping exchange/office premises in hygienic conditions.
8. Informing officer in charge Exchange/ BTS about any alarm/ fault
message immediately.
9. Any other work that may be identical and related to proper
upkeep of the telecom site.
Tuesday, April 07, 2015
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
6. Ensuring that the property is not tampered with Custodianship of
site.
4
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
HYDRAULIC DRY DISCONNECT COUPLING
Tuesday, April 07, 2015
5
HYDRAULIC DRY DISCONNECT COUPLING
• Available in Dry Disconnect type.
• No fuel spillage at the time of connection/disconnection.
• Female coupling is connected to the hose, and Male adapter on
the tank of genset.
• Tank is properly sealed and welded before the male adapter is
installed.
• Adapter on the tank ensures fuel cannot be siphoned off, as fuel
can enter from one direction only.
• Male adapter connects and permits passage of fuel only when it
is matched with the female coupling installed on the hose.
Tuesday, April 07, 2015
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
• Comes in 2 parts: Male adapter and female coupling.
6
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
DOOR OPEN
/ CLOSE
SENSOR
SMART CONTROLLER
AC POWER
FAILURE
SENSOR
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
TEMPERATURE & HUMIDITY
SENSOR
FUEL SENSOR
(LOW FUEL ALARM)
Tuesday, April 07, 2015
7
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
OTHER DEVICES:
• GENSET AUTO START/STOP
• DIGITAL DG HOUR METER
• AIR CONDITIONER AUTO START/STOP
• AVIATION LIGHT AUTO START/STOP
• HYDRAULIC COUPLINGS FOR FUEL RECEIPT IN TANK
Tuesday, April 07, 2015
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
• AUTO CHANGE OVER
8
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
DOOR OPEN
/ CLOSE
SENSOR
SMART CONTROLLER
MAINS
POWER
FAILURE
SENSOR
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
TEMPERATURE & HUMIDITY
SENSOR
FUEL SENSOR
(LOW FUEL ALARM)
Tuesday, April 07, 2015
9
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
SHELTER
AIR CONDITIONER
ON
SMS
OFF
28
26
24
22
20
TEMPERATURE
& HUMIDITY
SENSOR
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
TEMPERATURE & HUMIDITY SENSOR
SMART CONTROLLER
Tuesday, April 07, 2015
10
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
TEMPERATURE & HUMIDITY SENSOR
• Monitors temperature and humidity inside the shelter.
• As soon as temperature rises above 26o or humidity soars above
70%, the controller switches the AC on.
• As soon as temperature drops below 26o or humidity slides
below 70%, the controller switches the AC off.
•
SMS of entire event is sent to our server and up to 2 other
numbers.
•
Note: Any reference temperature/RH can be taken to switch AC on/off.
Tuesday, April 07, 2015
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
• Installed inside shelter.
11
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
DOOR OPEN
/ CLOSE
SENSOR
SMART CONTROLLER
MAINS
POWER
FAILURE
SENSOR
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
TEMPERATURE & HUMIDITY
SENSOR
FUEL SENSOR
(LOW FUEL ALARM)
Tuesday, April 07, 2015
12
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
AUTO
CHANGE
OVER
ON
OFF
GENSET
AUTO
START/STOP
MAINS
POWER
FAILURE
SENSOR
START
SMS
SMART CONTROLLER
Tuesday, April 07, 2015
13
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
MAINS POWER FAILURE SENSOR
• As soon as load shedding takes place, within 20 seconds,
generator starts automatically.
• Auto changeover transfers the load from mains to generator.
• On availability of mains again, the generator stops and
changeover transfers the load back to mains.
• SMS of entire event is sent to our server and up to 2 other
numbers.
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
• It is connected inside the Panel/Generator Self start box.
• Also, digital DG hour meter is installed to ensure tempering is
not done easily.
Tuesday, April 07, 2015
14
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
DOOR OPEN
/ CLOSE
SENSOR
SMART CONTROLLER
MAINS
POWER
FAILURE
SENSOR
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
TEMPERATURE & HUMIDITY
SENSOR
FUEL SENSOR
(LOW FUEL ALARM)
Tuesday, April 07, 2015
15
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
SMS
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
FUEL SENSOR (LOW FUEL ALARM
SMART CONTROLLER
Tuesday, April 07, 2015
16
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
FUEL SENSOR (LOW FUEL ALARM)
• As soon as fuel goes below a specific mark in the tank, the
control office is intimated automatically.
• Similar intimation can also be done on high level.
• SMS of entire event is sent to our server and up to 2 other
numbers.
Saturday, June 29, 2013
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
• It is installed inside the fuel tank of the Genset.
17
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
DOOR OPEN
/ CLOSE
SENSOR
SMART CONTROLLER
MAINS
POWER
FAILURE
SENSOR
Fuel Delivered. Anywhere.
Synergy Teletech Pvt. Ltd.
TEMPERATURE & HUMIDITY
SENSOR
FUEL SENSOR
(LOW FUEL ALARM)
Tuesday, April 07, 2015
18
TRANSITION FROM MANNED SITES TO
UNMANNED SITES
• It can be installed on the door of genset or main entrance gate of
premises.
• As soon as the door opens, alarm is triggered and central server
is intimated.
• SMS of entire event is sent to our server and up to 2 other
numbers.
• Similarly, aviation light can be switched on/off from remote by
sending an SMS to the controller.