Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. AUTOMATED SITE MANAGEMENT SYSTEM & DG PILFERAGE CONTROL SYSTEM 1 BACKGROUND Manned sites • Site fully dependent on attendant and he has to be present in there all the time. • Untrained and uneducated site attendant cannot maintain site record properly. Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. • Round the clock deployment of man power. Expensive. • Traditionally, manned sites account for more fuel pilferage than unmanned sites. Tuesday, April 07, 2015 2 NEED FOR HUMAN INTERVENTION??? WORK EXPECTED TO BE PERFORMED BY SITE ATTENDANT 2. Starting/ stopping of the DG set in case of power failure and auto start up failure and making entries in the log book. 3. Switching on and switching off of AC’s. 4. Cleaning of power plant, DG battery, firefighting equipment, other equipment at site Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. 1. Refueling of diesel in DG sets and maintaining log book of diesel refueling. 5. Answering of telephone, noting of complaints and passing information immediately to specified competent authority. Tuesday, April 07, 2015 3 NEED FOR HUMAN INTERVENTION??? WORK EXPECTED TO BE PERFORMED BY SITE ATTENDANT 7. Keeping exchange/office premises in hygienic conditions. 8. Informing officer in charge Exchange/ BTS about any alarm/ fault message immediately. 9. Any other work that may be identical and related to proper upkeep of the telecom site. Tuesday, April 07, 2015 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. 6. Ensuring that the property is not tampered with Custodianship of site. 4 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. HYDRAULIC DRY DISCONNECT COUPLING Tuesday, April 07, 2015 5 HYDRAULIC DRY DISCONNECT COUPLING • Available in Dry Disconnect type. • No fuel spillage at the time of connection/disconnection. • Female coupling is connected to the hose, and Male adapter on the tank of genset. • Tank is properly sealed and welded before the male adapter is installed. • Adapter on the tank ensures fuel cannot be siphoned off, as fuel can enter from one direction only. • Male adapter connects and permits passage of fuel only when it is matched with the female coupling installed on the hose. Tuesday, April 07, 2015 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. • Comes in 2 parts: Male adapter and female coupling. 6 TRANSITION FROM MANNED SITES TO UNMANNED SITES DOOR OPEN / CLOSE SENSOR SMART CONTROLLER AC POWER FAILURE SENSOR Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. TEMPERATURE & HUMIDITY SENSOR FUEL SENSOR (LOW FUEL ALARM) Tuesday, April 07, 2015 7 TRANSITION FROM MANNED SITES TO UNMANNED SITES OTHER DEVICES: • GENSET AUTO START/STOP • DIGITAL DG HOUR METER • AIR CONDITIONER AUTO START/STOP • AVIATION LIGHT AUTO START/STOP • HYDRAULIC COUPLINGS FOR FUEL RECEIPT IN TANK Tuesday, April 07, 2015 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. • AUTO CHANGE OVER 8 TRANSITION FROM MANNED SITES TO UNMANNED SITES DOOR OPEN / CLOSE SENSOR SMART CONTROLLER MAINS POWER FAILURE SENSOR Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. TEMPERATURE & HUMIDITY SENSOR FUEL SENSOR (LOW FUEL ALARM) Tuesday, April 07, 2015 9 TRANSITION FROM MANNED SITES TO UNMANNED SITES SHELTER AIR CONDITIONER ON SMS OFF 28 26 24 22 20 TEMPERATURE & HUMIDITY SENSOR Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. TEMPERATURE & HUMIDITY SENSOR SMART CONTROLLER Tuesday, April 07, 2015 10 TRANSITION FROM MANNED SITES TO UNMANNED SITES TEMPERATURE & HUMIDITY SENSOR • Monitors temperature and humidity inside the shelter. • As soon as temperature rises above 26o or humidity soars above 70%, the controller switches the AC on. • As soon as temperature drops below 26o or humidity slides below 70%, the controller switches the AC off. • SMS of entire event is sent to our server and up to 2 other numbers. • Note: Any reference temperature/RH can be taken to switch AC on/off. Tuesday, April 07, 2015 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. • Installed inside shelter. 11 TRANSITION FROM MANNED SITES TO UNMANNED SITES DOOR OPEN / CLOSE SENSOR SMART CONTROLLER MAINS POWER FAILURE SENSOR Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. TEMPERATURE & HUMIDITY SENSOR FUEL SENSOR (LOW FUEL ALARM) Tuesday, April 07, 2015 12 TRANSITION FROM MANNED SITES TO UNMANNED SITES Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. AUTO CHANGE OVER ON OFF GENSET AUTO START/STOP MAINS POWER FAILURE SENSOR START SMS SMART CONTROLLER Tuesday, April 07, 2015 13 TRANSITION FROM MANNED SITES TO UNMANNED SITES MAINS POWER FAILURE SENSOR • As soon as load shedding takes place, within 20 seconds, generator starts automatically. • Auto changeover transfers the load from mains to generator. • On availability of mains again, the generator stops and changeover transfers the load back to mains. • SMS of entire event is sent to our server and up to 2 other numbers. Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. • It is connected inside the Panel/Generator Self start box. • Also, digital DG hour meter is installed to ensure tempering is not done easily. Tuesday, April 07, 2015 14 TRANSITION FROM MANNED SITES TO UNMANNED SITES DOOR OPEN / CLOSE SENSOR SMART CONTROLLER MAINS POWER FAILURE SENSOR Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. TEMPERATURE & HUMIDITY SENSOR FUEL SENSOR (LOW FUEL ALARM) Tuesday, April 07, 2015 15 TRANSITION FROM MANNED SITES TO UNMANNED SITES SMS Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. FUEL SENSOR (LOW FUEL ALARM SMART CONTROLLER Tuesday, April 07, 2015 16 TRANSITION FROM MANNED SITES TO UNMANNED SITES FUEL SENSOR (LOW FUEL ALARM) • As soon as fuel goes below a specific mark in the tank, the control office is intimated automatically. • Similar intimation can also be done on high level. • SMS of entire event is sent to our server and up to 2 other numbers. Saturday, June 29, 2013 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. • It is installed inside the fuel tank of the Genset. 17 TRANSITION FROM MANNED SITES TO UNMANNED SITES DOOR OPEN / CLOSE SENSOR SMART CONTROLLER MAINS POWER FAILURE SENSOR Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. TEMPERATURE & HUMIDITY SENSOR FUEL SENSOR (LOW FUEL ALARM) Tuesday, April 07, 2015 18 TRANSITION FROM MANNED SITES TO UNMANNED SITES • It can be installed on the door of genset or main entrance gate of premises. • As soon as the door opens, alarm is triggered and central server is intimated. • SMS of entire event is sent to our server and up to 2 other numbers. • Similarly, aviation light can be switched on/off from remote by sending an SMS to the controller. Tuesday, April 07, 2015 Fuel Delivered. Anywhere. Synergy Teletech Pvt. Ltd. DOOR OPEN / CLOSE SENSOR 19