SightScope Prescriber Webinar

advertisement
Easy and affordable to prescribe
Widest field of view available
Your patients will love it!
OCUTECH, Inc.
www.ocutech.com
Sightscope FLIP features:
• Crisp, bright Galilean Optical Design
1.7x, 2.2x powers
• Exceptionally wide binocular field of view
1.7x = 32.5˚
•
•
•
•
•
2.2x = 22.5˚
Completely adjustable- PD and Line of Sight
Binocular or monocular options
Reading caps for near working distances
3 Standard frame options
2 Clip-on versions
OCUTECH
Technical Specs
Power
Visual
Acuity
Binocular
Field of
View
Monocular
Field of View
Near Focus
Range
1.7X
~20/70
or better
32.5˚
26˚
~ 5 feet
2.2X
~20/100
or better
22.5˚
18˚
~7 feet
OCUTECH
Benefits to the prescriber
•
•
•
•
•
•
Simple to fit and demonstrate
No special measurements required
As easy to fit as eyeglasses
Patient response is immediate
Multiple prescription options
Re-usable!
Benefits to your patients
– More natural
– More comfortable
– Very wide field of view
– No focusing
– Flip it out of the way
– Hi-tech appearance
OCUTECH
Frame Prescription options
Bioptic Position
– Ocutech “K” frame
– Ocutech Unisex frame
Full Diameter Position
- Ocutech “Sleek” frame
OCUTECH
Fitting the SightScope
Step 1. Set eyepiece PD position
Slide each telescope right and left
OCUTECH
2. Set the vertical position
Bioptic positioning
OCUTECH
2. Set the vertical position
Full diameter positioning
OCUTECH
3. Adjust the Viewing Angle
OCUTECH
3. Adjust the viewing angle
Wrong!
RIGHT!
OCUTECH
4. Separate the eyepieces
Maximize the field of view ~ 20%
OCUTECH
Flip it out of the way!
OCUTECH
Accessories
Reading Caps:
Reading, Computer, table top (Cards!)
+1.00, +1.50, +2.00, +2.50, +3.00
Working distances 13” to 40”
Base-in prism to fuse at near
Slip-behind Filters:
Gray, Blue-blocker, Brown, Amber
Achromatopsia Red
OCUTECH
Demonstration Options
• Spectacle mounted system
– No distance Rx
• Demo Clip-on system
– Over patient’s Rx
OCUTECH
Patient Clip-on Options
Demonstrator Plastic Clip
Metal Spring Clip
OCUTECH
Prescribing Decisions
• TS Power
– Goal: ~ 20/40 through the TS
• Carrier lenses
– Rx what they normally wear
– Avoid progressives or trifocals
• NO eyepiece corrections needed
• Choose frame type
– Distance applications- Bioptic position (K or U frames)
– Mid-range applications- Full Diameter position (Sleek frame)
• Binocular even if poor VA in fellow eye
OCUTECH
What your colleagues
are saying…
We've had nothing but positive experiences with the new
SightScope. It's simple to demonstrate, easy for the patient to see
through the first time, and of course the price has been a positive.
Kendall Krug, OD
Diplomate, American Board of Optometry, Hays, KS
...I am loving the SightScope, We've already prescribed quite a few.
Lynne Noon, OD, FAAO
Diplomate in Low Vision Rehabilitation, Phoenix, AZ
You have an excellent product with the SightScope. Please let
everyone at Ocutech know. Congrats
Melissa Chun, O.D., F.A.A.O., Diplomate in Low Vision
Director, Vision Rehabilitation Center, Jules Stein Eye Institute, Los
Angeles, CA
OCUTECH
Want to bring SightScope into
your practice…
• Contact Ocutech at:
• info@ocutech.com
• 800 326-6460
• +1 919 967 6460
• 919 967-8146 (Fax)
OCUTECH
Download