INTERACTIVE GAME-BASED REHABILITATION USING FORCE SENSORS PROJECT REPORT Submitted by NIVEEN A (2022116039) ARULDHA RAJA AISWARYA CA (2022116042) HILTON PAUL A (2022116314) in partial fulfillment for the award of the degree of BACHELOR OF ENGINEERING IN BIOMEDICAL ENGINEERING COLLEGE OF ENGINEERING, GUINDY, ANNA UNIVERSITY: CHENNAI – 600 025. APRIL, 2026 i ANNA UNIVERSITY: CHENNAI 600 025 BONAFIDE CERTIFICATE Certified that this project report “INTERACTIVE GAME-BASED REHABILITATION USING FORCE SENSORS” is the bonafide work of “NIVEEN A (2022116039), ARULDHA RAJA AISWARYA CA (2022116042), HILTON PAUL A (2022116314)” who carried out the project work under my supervision. SIGNATURE Dr. M. SASIKALA HEAD OF THE DEPARTMENT PROFESSOR, DEPARTMENT OF BIOMEDICAL ENGINEERING, COLLEGE OF ENGINEERING, GUINDY, ANNA UNIVERSITY, CHENNAI-600025 ii SIGNATURE Dr. T. JAYASREE SUPERVISOR ASSISTANT PROFESSOR (Sl, Gr) DEPARTMENT OF BIOMEDICAL ENGINEERING COLLEGE OF ENGINEERING, GUINDY, ANNA UNIVERSITY, CHENNAI-600025 ACKNOWLEDGEMENT We owe our sincere thanks to the Head of the Department of Biomedical Engineering, Dr. M. SASIKALA for her continuous encouragement during the project work. We express our unfathomable gratitude to our project guide and respectable mentor Dr. T. JAYASHREE, Assistant Professor (Sl. Gr.), Department of Biomedical Engineering for nurturing us and encouraging throughout our project work. We would like to show our appreciation to Project Coordinators Dr. B.S. SREEJA, Associate Professor and Dr. D. KALYANI, Teaching Fellow for giving us valuable guidance for the project throughout numerous consultations. We would also like to extend our deepest gratitude to all those who have directly and indirectly guided us in carrying out and completing this project successfully. We owe our refined thanks to all other encouraging teaching faculty and nonteaching staffs in the department and our classmates who have assisted us to make our project work efficacious. NIVEEN A 2022116039 ARULDHA RAJA AISWARYA C A 2022116042 HILTON PAUL A 2022116314 iii ABSTRACT Upper-limb rehabilitation often becomes repetitive and lacks measurable feedback, leading to poor patient motivation and limited clinician insight. This project develops an interactive game-based rehabilitation system that uses Force Sensing Resistors (FSRs integrated into resistance band handles to monitor patient effort during exercise. The sensors capture force and bending movement, and the data is processed by an ESP32 microcontroller, which transmits it in real time to a computer-based game. The FSR is calibrated using known weights, and a polynomial curve-fitting method is applied to convert sensor voltage into accurate force values. Basic preprocessing techniques, such as averaging and noise reduction, ensure stable and smooth input for game control. The game maps the user’s applied force to character movement, making rehabilitation more engaging, motivating, and interactive. All performance data, including force levels and repetitions, is stored and displayed through a simple dashboard, enabling therapists to track progress. The developed prototype is low-cost, portable, and improves rehabilitation effectiveness by combining real-time sensing, gamification, and measurable feedback. iv திட்டப் பணி சுருக்கம் மேல் -கை ேறுவாழ் வு (upper-limb rehabilitation) ப ாதுவாை ஒமே ோதிேியான இதில் யிற் சிைகை ப ாடே்ந்து பெய் ய மவண்டியுை் ைது. அைவிடை்கூடிய குகறவாை இரு ் ைரு ் ைி ்பு ால் , (measurable மநாயாைிைைின் feedback) உற் ொைே் குகறவதுடன் , ேரு ்துவ நிபுணே்ைளுை்குே் முன் மனற் ற க ் ப ைிவாை அறிய இயலா நிகல ஏற் டுகிறது. இந் Force Sensing Resistors (FSRs) எதிே் ்பு கை ் பிடிைமைாடு திட்டே் , ட்கடைைின் (resistance band) ஒருங் கிகண ்து, யிற் சியின் ம ாது மநாயாைி பெலு ்துே் முயற் சிகய ைண்ைாணிை்குே் , இகணய நடவடிை்கையுை் ை ேறுவாழ் வு அகே ் க பென் ொே்ைை் யன் இயை்ை க ் ் விகையாட்டு (interactive) உருவாை்குகிறது. டு ் ் டுே் வலிகே ேற் றுே் வகை ்பு திவு பெய் கின் றன. இந் கேை்மோைண்ட்மோலே் அடி ் கடயிலான ஆ ாேோன ேவுைகை ESP32 மநேடியாை பெயலாை்கி, ைணினி விகையாட்டிற் கு real-time முகறயில் அனு ்புகிறது. FSR, அறிய ் ட்ட எகடைகை (known weights) அைவு ்திரு ் ே் மின் னழு ் க ் (calibration) யன் பெய் ய ் டுகிறது. துல் லியோன வலிகே டு ்தி பென் ொே் ேதி ் புைைாை ோற் றுவ ற் ைாை ல் டிவ வகைவு ப ாரு து ் ல் (polynomial curve-fitting) முகற ் யன் டு ் ் டுகிறது. ெோெேி ைணை்கீடு ேற் றுே் ெ ் ை்குகற ் ல் (noise reduction) ம ான் ற அடி ் கட v முன் -பெயலாை்ை யன் டு ் நுட் ங் ைை் ் ட்ட ால் (preprocessing விகையாட்டு techniques) ைட்டு ் ாட்டிற் ைான உை் ைடு ீ ைை் நிகலயான ேற் றுே் சீோன ாை ோறுகின் றன. யனே் யன் டு ்துே் ை ா ா ்திே ்தின் இகணை்ை ் டுவ ால் , வலிகே, விகையாட்டு இயை்ை ்துடன் மநேடியாை ேறுவாழ் வு பெயல் முகற மேலுே் ஈே்ை்குே் , ஊை்ைேைிை்குே் ேற் றுே் ப ாடே் ாடல் நிகறந் ாை ோறுகிறது. போழுகேயான பெயல் திறன் ேவுைை் — வலிகே அைவுைை் ேற் றுே் மீளுருவாை்ை எண்ணிை்கை ம ான் றகவ — எைிய டாஷ்ம ாே்டின் மூலே் ைாட்சி ் டு ் ் டுகின் றன, இ ன் முன் மனற் ற க ் ைண்ைாணிை்ை gamification ேற் றுே் ஒருங் கிகண ் (prototype) எடு ்துெ் measurable மூலே் மெமிை்ை ் ட்டு சிகிெ்கெயாைே் முடிகிறது. real-time sensing, feedback ஆகியவற் கற ன் மூலே் , உருவாை்ை ் ட்ட இந் குறுகிய பெலவில் முன் ோதிேி பெயல் டை்கூடியது, பெல் லை்கூடியது, பெயல் திறகன மேே் டு ்துகிறது. vi மேலுே் எைிதில் ேறுவாழ் வின் TABLE OF CONTENTS CHAPTER CONTENTS LIST OF FIGURES PG NO LIST OF TABLES 1 2 3 INTRODUCTION 1.1 UPPER LIMB REHABILITATION 1.2 LIMITATIONS OF CONVENTIONAL THERAPY 1.3 SENSOR-BASED REHABILITATION SYSTEMS 1.4 NEED FOR GAME-BASED INTERACTIVE REHABILITATION 1.5 OBJECTIVES 1.6 SCOPE OF THE PROJECT LITERATURE REVIEW 2.1 REVIEW OF RELATED WORKS 2.2 LITERATURE SUMMARY METHODOLOGY 3.1 INTRODUCTION 3.2 BLOCK DIAGRAM 3.3.1 RESISTANCE BAND EXERCISES STRENGTHEN MUSCLES 3.3.2 POSTURE CORRECTION 3.4 HARDWARE MODULES 3.4.1 FORCE SENSING RESISTOR (FSR) 3.4.2 INERTIAL MEASUREMENT UNIT (IMU) 3.4.3 ESP32 MICROCONTROLLER 3.5 SENSOR INTEGRATION 3.6 FSR CALIBRATION 3.7 IMU THRESHOLD 3.8 COMMUNICATION BETWWN ESP32 AND GAME vii 1 1 1 2 2 3 3 4 4 6 8 8 8 10 11 12 12 13 14 15 17 17 17 4 5 3.9 GAME DEVELOPMENT AND DATA PROCESSING WORK FLOW 3.9.1 MOVING AVERAGE FILTERING 3.9.2 CALIBRATION THRESSHOLD ETIMATION 3.9.3 NORMALIZATION MAPPING 3.9.4 PLAYER MOVEMENT SPEED (FOREST RUN) 3.9.5 DISTANCE COMPUTATION (FOREST RUN) 3.9.6 RELEASE DETECTION (ARCHERY) 3.9.7 PROJECTILE COMPUTATION FOR WEAK SHOTS 3.9.8 VELOCITY ESTIMATION FOR STRONG SHOTS 3.10 GAME INTERFACE AND MAPPING LOGIC 3.11 IMU-BASED GAME LOGIC AND INTEGRATION RESULTS 4.1 INTEGRATION OF FSR 4.1.1 CALIBRATION 4.2 IMU-BASED POSTURE DETECTION 4.3 HARDWARE INTEGRATION USING BROWN BOARD (ESP32+FSR+IMU) 4.4 SENSOR ATTACHMENT TO BAND 4.5.1 GAME MAIN MENU INTERFACE 4.5.2 FOREST RUN REAL TIME GAME OUTPUT 4.5.3 BOW & ARROW GAME REAL TIME ARCHERY MODULE 4.6 SESSION DASHBOARD AND STORAGE 4.7 FOREST RUN GAME - RESULT INTERPRETATION 4.8 BOW AND ARROW GAME – RESULT INTERPRETATION 4.9 PERFORMANCE IMPROVEMENT CONCLUSION viii 18 18 19 19 20 20 21 21 22 23 24 25 25 26 28 29 30 31 32 33 34 36 36 37 39 LIST OF FIGURES FIGURE NO TITLE 3.1 Block Diagram PAGE NO 9 3.2 Muscles Activated by Exercise 10 3.3 Posture Difference 12 3.4 Force Sensitive Resistor 13 3.5 Inertial Measurement Unit 13 3.6 ESP32 Microcontroller 14 3.7 FSR Integration with ESP32 15 3.8 IMU Integration with ESP32 16 3.9 FSR Sensor Simulation 16 3.10 The game-mapping logic flow 23 4.1 FSR Sensor Integration 25 4.2 Graphical representation of the FSR response 27 4.3 Calibration of FSR 27 4.4 Posture Detection using IMU 28 4.5 Brwon Board Soldering 29 4.6 Sensor placement on resistance band 30 4.7 Patient login interface 31 4.8 Main Menu interface showing game mode selection 32 4.9 Forest Run Gameplay 33 4.10 Archery Gameplay 34 4.11 Dashboard after each session 35 ix LIST OF TABLES TABLE NO 3.1 4.1 4.2 4.3 4.4 TITLE Technical Specifications of ESP32 FSR Response to Load Subject Data – Forest run game Subject Data – Bow and Arrow game Performance of a subject recorded over time x PAGE NO 15 26 36 37 38 CHAPTER 1 INTRODUCTION 1.1 UPPER LIMB REHABILITATION Upper limb rehabilitation is a vital component in restoring functional movement, strength, and coordination for individuals recovering from injuries such as rotator cuff tears, fractures, tendinopathies, nerve injuries, or post-surgical conditions. The rehabilitation process commonly involves repetitive exercises using equipment such as resistance bands, weights, and mobility tools. These exercises help improve muscle activation, joint stability, range of motion, and neuromuscular control. However, conventional rehabilitation relies heavily on therapist supervision and patient self-reporting, making it difficult to obtain objective measurements of applied force and progress over time. Lack of continuous feedback during exercises may also result in poor engagement, reduced adherence, and incorrect execution of movements. 1.2 LIMITATIONS OF CONVENTIONAL THERAPY Traditional rehabilitation methods are often monotonous and provide limited quantitative information regarding patient performance. Therapists cannot accurately measure the force exerted in each repetition, and patients lack immediate feedback to correct their technique. Home-based exercises further contribute to inconsistency, as patients may perform exercises with inadequate force, incorrect posture, or reduced motivation. With no real-time monitoring or engaging system in place, the therapeutic outcome depends largely on patient discipline rather than measurable progress. This creates a gap in ensuring effective, safe, and sustained rehabilitation. 1 1.3 SENSOR-BASED REHABILITATION SYSTEMS Recent advancements in biomedical sensors and embedded systems have led to the development of interactive rehabilitation tools that combine sensing, computation, and feedback mechanisms. Force Sensing Resistors (FSRs) and flex sensors enable the measurement of force, bending, and movement patterns. When integrated with microcontrollers such as ESP32, these sensors provide real-time data for monitoring exercise intensity and motion. Gamified interfaces transform exercise routines into engaging tasks, improving patient adherence and motivation. Real-time force monitoring also helps ensure that exercises are performed within the recommended therapeutic range, reducing the risk of overexertion or improper technique. 1.4 NEED OF GAME-BASED INTERACTIVE REHABILITATION Gamification introduces reward systems, visual feedback, challenges, and performance tracking, making therapy more enjoyable and outcome-driven. By mapping force and movement data to game mechanics, patients receive immediate reinforcement for correct performance. This approach offers: • Enhanced patient engagement • Increased exercise repetitions • Objective and continuous data collection • Therapist access to progress analytics • Customizable difficulty levels based on patient capability 2 Integrating FSR-based sensing with a real-time game interface addresses both the motivational and quantitative deficits in conventional therapy. 1.5 OBJECTIVES The objectives of the present work are: • To integrate FSR sensors into resistance band handles for real-time force measurement during upper limb exercises • To transmit sensor data to a computer interface using ESP32. • To develop an interactive game controlled by patient-generated force values. • To ensure safe rehabilitation by monitoring whether patients remain within prescribed force limits. • To store performance metrics for long-term tracking and therapeutic decisionmaking. 1.6 SCOPE OF THE PROJECT The scope of this project includes the hardware design of a resistance-bandbased sensing setup, calibration of FSR and IMU sensors, development of a realtime communication system using ESP32, and creation of a game interface that responds to sensor input. The work focuses on upper-limb strengthening and control exercises utilizing elastic resistance bands. The system is designed to be low-cost, portable, and suitable for both clinical and home-based use. Future extensions may include multi-joint tracking, adaptive difficulty adjustment, mobile platform integration, and cloud-based therapist dashboards. 3 CHAPTER 2 LITERATURE REVIEW The Efficacy of Upper-Extremity Elastic Resistance Training on Shoulder Strength and Performance (Rachel C Seguin, Alan C Cudlip, Michael W R Holmes, 2022) Seguin et al. (2022) evaluated the efficacy of upper-extremity elastic resistance training on improving shoulder strength and functional performance. Their review of multiple clinical trials highlighted that elastic resistance bands provide progressive loading, promote higher muscle activation, and significantly enhance upper-limb function with minimal equipment requirements. The authors concluded that elastic resistance exercises are comparable to conventional weightbased strengthening for restoring shoulder and arm power. Since elastic bands generate quantifiable increases in force as they elongate, this study supports their suitability for integration with FSR sensors to measure patient effort during rehabilitation. Their findings provide a strong therapeutic basis for selecting elastic resistance as the central mechanism in developing a sensor-based, game-driven upper-limb rehabilitation system. A 2023 study on wearable sensors for activity monitoring and motion control further explored the application of force-sensitive resistors (FSRs) and flex sensors in rehabilitation technology. The researchers developed a prototype handle incorporating both sensing elements to assess grip force and wrist flexion during therapeutic exercises. Their analysis revealed that combining force and flex data improved the precision of movement evaluation and enhanced the ability to detect patient effort. These findings directly support the integration of FSR and flex sensors within elastic resistance band handles. The study confirms that sensor fusion 4 provides more comprehensive exercise assessment and that FSRs reliably capture applied force, which is essential for enabling real-time feedback in interactive rehabilitation games. Gamification of Upper Limb Rehabilitation in Mixed-Reality (Aditya Pillai, Md Samiul Haque Sunny, Md Tanzil Shahria, Nayan Banik, Mohammad Habibur Rahman, 2023) Pillai et al. (2023) investigated the application of mixed-reality gamification for upper-limb rehabilitation by developing an interactive platform in which patient movement controlled an on-screen character through real-time sensor input. Their study reported notable improvements in patient motivation, adherence to therapy, and the total number of exercise repetitions when compared with conventional rehabilitation methods. The authors emphasized that real-time visual feedback enabled patients to maintain appropriate exercise intensity, thereby supporting safer and more effective training. Their findings confirm that gamification enhances compliance and therapeutic outcomes, providing strong justification for the gamebased design adopted in our rehabilitation system. The study also highlighted the role of continuous feedback in preventing both under-exertion and over-exertion, which aligns directly with our implementation of force thresholds and adaptive game difficulty to guide patient effort during upper-limb exercises. Real-Time Sensor-Based Monitoring of Resistance Exercises for UpperLimb Rehabilitation(Ciro Mennella, Umberto Maniscalco, GiuseppeDe Pietro, 2022) Mennella et al. (2022) developed a real-time sensor-based monitoring system for upper-limb resistance exercises by integrating force and motion sensors into a 5 smart training device. Their platform provided continuous feedback to guide correct technique and enabled therapists to remotely assess exercise quality and patient progress. The authors reported high measurement accuracy along with improved adherence when patients used the sensor-enhanced device. Their findings offer strong support for incorporating sensors into resistance bands and transmitting the processed data to an external feedback system, such as a computer game in our project. The study further validates the therapeutic importance of objective performance tracking, aligning directly with our use of a cloud-based dashboard to monitor patient metrics and quantify rehabilitation outcomes. A Survey of Datasets, Applications, and Models for IMU Sensor Signals (Aparajita Saraf, Seungwhan Moon, Andrea Madotto, 2023) This paper provides a comprehensive overview of how IMU sensors are used to capture human motion and posture through accelerometer and gyroscope data. It highlights that IMUs are widely applied in areas such as activity recognition, posture detection, and rehabilitation monitoring due to their ability to provide continuous, real-time orientation information. The paper also emphasizes that threshold-based and model-based approaches can effectively interpret IMU signals to classify body posture and detect deviations. 2.1 LITERATURE SUMMARY The papers collectively show that elastic resistance training is effective for upper-limb rehabilitation and that embedding sensors such as FSRs and flex sensors provides accurate, real-time measurement of patient effort. Studies demonstrate that gamification significantly enhances engagement and exercise consistency, while signal preprocessing is critical for ensuring stable interaction. Additionally, recent work highlights the ESP32 microcontroller as an efficient platform for wireless, low6 cost rehabilitation systems. Together, these findings provide strong scientific justification for our project’s design choices, which combine resistance-band exercises, FSR-based sensing, ESP32 processing, and a game-based interactive feedback system to create a measurable, engaging, and clinically relevant upperlimb rehabilitation platform. The last paper supports the use of IMU for real-time posture detection using orientation data (pitch/roll) and validates our approach of using threshold-based posture correction to control rehabilitation gameplay. 7 CHAPTER 3 METHODOLOGY 3.1 INTRODUCTION The proposed work aims to develop an interactive, game-based upper-limb rehabilitation system by integrating Force Sensing Resistors (FSRs) into resistance band handles and an IMU sensor for posture correction. The system transforms conventional resistance-band exercises into a measurable and engaging therapeutic experience. When the user performs an exercise, the FSR detects the applied force. This analog signal is processed by an ESP32 microcontroller, which transmits the data in real time to a computer. A custom-designed game uses this sensor data to generate visual feedback, allowing the user to control game elements based on exercise intensity. This approach enhances motivation, improves adherence, and provides objective performance metrics for both users and therapists. 3.2 BLOCK DIAGRAM The block diagram represents the complete workflow of the wireless upperlimb rehabilitation system, consisting of hardware, software, and user interface components. In the hardware section, a resistance band integrated with two FSR sensors is used to measure the force applied by the user during exercises. These sensors are connected to an ESP32 microcontroller, along with an IMU sensor that monitors the user’s posture. All components are assembled on a custom soldered brown board and powered by a battery, making the system portable. The ESP32 collects and processes both force and posture data and transmits it wirelessly to the laptop. 8 In the software layer, the incoming sensor data is processed and used for further analysis and integration. The system supports real-time data handling, where FSR and IMU outputs are interpreted for game control and posture validation. Additionally, performance data can be stored through a dashboard and cloud system, enabling tracking of user sessions and rehabilitation progress. This layer ensures smooth communication between hardware and the application, allowing real-time responsiveness. Figure 3.1 Block Diagram In the user interface, the processed data is integrated into a Unity-based rehabilitation game running on a PC. The FSR sensors control game mechanics such as character speed in the running game and bow stretching in the archery game, while the IMU ensures that the game operates only when the user maintains correct posture. The system provides real-time feedback through scores, performance metrics, and graphical visualization of FSR output. Overall, the block diagram demonstrates the integration of sensing, processing, and interactive gaming to create an effective and engaging rehabilitation platform. 9 3.3.1 Resistance Band Exercises Strengthen Muscles Resistance band exercises strengthen upper-limb muscles by providing progressive, elastic resistance that increases as the band is stretched. Unlike weights, where the load remains constant, the force required in a resistance band increases nonlinearly with elongation. This means that as the user pulls the band further, the muscles must contract harder to overcome the rising tension. This mechanism directly activates major upper-limb muscle groups such as the biceps, triceps, deltoid, rotator cuff muscles, and forearm flexors/extensors which are mentioned in the figure 3.2. Figure 3.2 Muscles activated by exercise This progressive increase in force is extremely important, because the FSR fitted inside the band handle exactly captures this variation in force. When the user pulls the band harder, the FSR detects the increased pressure in the grip and converts it into a measurable change in resistance. This allows our system to quantify muscle effort in real time, transforming a traditional strengthening exercise into measurable data. As muscles generate greater tension to stretch the band, the flex sensor also bends according to the angle or posture of the upper limb. This helps monitor the quality of movement, ensuring that the user performs strengthening exercises with 10 correct form. Proper alignment enhances muscle activation and prevents compensation or injury. The ESP32 collects these sensor inputs and sends the data continuously to the game. The game responds proportionally: • Higher force → faster or stronger game action • Lower force → slower game response This real-time feedback encourages the user to apply adequate muscle effort, maintain consistency, and progressively increase strength. Over repeated sessions, this combination of progressive resistance + quantified effort + gamified motivation leads to measurable improvements in: • Muscle strength • Endurance • Neuromuscular coordination • Joint stability Therefore, resistance band exercises strengthen upper-limb muscles not only biomechanically but also through biofeedback, where our system tracks force production, encourages higher recruitment of muscle fibers, and ensures a structured strengthening routine. By embedding sensors and game-based feedback, the project enhances the traditional benefits of resistance training and makes the strengthening process measurable, engaging, and therapeutically effective. 3.3.2 POSTURE CORRECTION The IMU sensor plays a crucial role in posture correction by continuously monitoring the orientation of the user’s upper body through parameters such as pitch and roll. By comparing real-time orientation data with a calibrated upright reference, 11 the system detects deviations like slouching or forward bending and restricts the game when incorrect posture is observed. This ensures that exercises are performed only under proper biomechanical alignment. Fig.3.3 Posture Difference (Left- crouched, Right- upright) Correct posture is essential in upper-limb strengthening because it stabilizes the trunk, allows efficient force generation, and prevents compensatory movements that can reduce exercise effectiveness or lead to injury. By enforcing proper posture, the IMU helps ensure that the targeted muscles are engaged correctly, thereby improving rehabilitation outcomes and safety. 3.4 HARDWARE MODULES 3.4.1 Force Sensing Resistor (FSR) The FSR which is shown in the figure 3.3 is used to detect the force applied to the resistance band handle. The resistance of the sensor decreases with increasing applied pressure. In this system, the FSR is connected using a voltage-divider 12 configuration to output an analog voltage proportional to the pulling force. This input serves as the primary control parameter for the rehabilitation game. Figure 3.4 Force Sensitive Resistor 3.4.2 Inertial Measurement Unit (IMU) Figure 3.5 Inertial Measurement Unit sensor The Inertial Measurement Unit (IMU) is a compact sensor used to measure body motion and orientation by combining data from a 3-axis accelerometer, gyroscope, and magnetometer. It provides real-time information such as pitch, roll, and yaw angles, which represent the orientation of the body segment where it is placed. In this project, the IMU is used to monitor the user’s upper body posture during rehabilitation exercises. By continuously tracking orientation, the IMU enables accurate detection of posture changes and ensures that movements are 13 performed correctly. Its wireless capability, high accuracy, and real-time output make it highly suitable for wearable rehabilitation and motion analysis applications. 3.4.3 ESP32 Microcontroller The ESP32 which is shown in the figure 3.4 acts as the central processing unit for the system. It reads the analog outputs of both sensors, applies preprocessing, and transmits the data to the game interface. The ESP32’s built-in WiFi/Bluetooth capabilities make it suitable for real-time communication. The microcontroller is powered by a 3.3V lithium-ion battery and interfaces with the PC through serial communication or Wi-Fi. The technical specifications of ESP32 are given in Table 3.1. Figure 3.6 ESP32 Microcontroller 14 Table 3.1 Technical Specifications of ESP32 S.NO SPECIFICATIONS TYPE/RANGE 1. Operating voltage/Power supply 3.0-3.6 V 2. Operating current 80 mA 3. Wi-Fi: Center frequency range of operating 2412 ~ 2484 MHz channel 4. Bluetooth NZIF receiver with –97 dBm sensitivity 5. Microprocessor Two Xtensa® 32-bit LX6 microprocessors 3.5 SENSOR INTEGRATION The FSR and flex sensors are embedded inside the resistance band handle and fixed securely to ensure stable measurements. Figure 3.7 represents the interfacing of the sensor with the ESP32. The FSR is placed where the user applies gripping pressure. Figure.3.7 FSR integration with ESP32 15 Figure 3.8 represents the interfacing of the sensor with the ESP32. The IMU is placed along with the ESP32 in the breadboard which is attached to a belt that is worn around the back for posture detection. Figure.3.8 IMU integration with ESP32 The simulation of FSR sensor integration with ESP32 and output generation is done in a software as shown in figure 3.9. Figure 3.9 FSR sensor simulation 16 3.6 FSR CALIBRATION Calibration is carried out by applying known weights to the FSR and recording the corresponding ADC values. The values are tabulated and plotted to obtain a force–voltage relationship. A polynomial curve-fitting algorithm in Python is used to generate a calibration equation: 𝐹𝑜𝑟𝑐𝑒 = 𝑎(𝑉)2 + 𝑏(𝑉) + 𝑐 (3.1) This equation is implemented in the game code to convert real-time sensor voltage into accurate force estimation. 3.7 IMU THRESHOLD The pitch threshold for posture detection is set using the IMU by first calibrating the sensor in a correct upright sitting position, which is taken as the reference baseline (approximately 0° pitch). During operation, the IMU continuously measures the pitch angle of the user’s torso, and this value is compared against a predefined threshold range (for example, ±10° from the baseline). If the measured pitch remains within this range, the posture is considered correct and the system allows normal operation. However, if the pitch exceeds the threshold (indicating forward slouching or bending), the posture is classified as incorrect, and the system restricts or pauses the game. This threshold-based approach enables simple, real-time posture validation and ensures that exercises are performed with proper alignment. 3.8 COMMUNICATION BETWEEN ESP32 AND GAME ESP32 transmits the calibrated force value to the game running on a PC. Two modes are possible: 1. USB Serial Communication 17 2. Wireless Communication (WiFi/Bluetooth) The PC continuously reads these values and updates the game state in real time. 3.9 GAME DEVELOPMENT AND DATA PROCESSING WORKFLOW In the proposed rehabilitation system, the game serves as the primary medium for providing real-time visual feedback to the user. To ensure that the game responds accurately to the force applied on the resistance band and the bending measured by the flex sensor, a structured data handling and preprocessing pipeline is implemented. This pipeline converts raw sensor readings into clean, meaningful inputs that can be mapped to the game logic effectively. The complete workflow consists of four major stages: data acquisition, CSV-based storage, preprocessing in VS Code, and real-time integration into the game. 3.9.1 Moving Average Filtering To reduce noise and fluctuations in the raw sensor signal, a moving average filter was applied. The smoothed voltage at time 𝑡 was calculated using Equation (3.2): 𝑁−1 1 𝑉smooth (𝑡) = ∑ 𝑉(𝑡 − 𝑖) 𝑁 (3.2) 𝑖=0 where 𝑉(𝑡) represents the raw voltage sample at time 𝑡, 𝑁 is the number of recent samples considered (in this work 𝑁 = 5), and 𝑉smooth (𝑡) is the averaged voltage value used for further processing. The filtered value obtained from Equation (3.2) ensured smoother and more stable control of the game character, avoiding sudden jumps due to sensor noise. 18 3.9.2 Calibration Threshold Estimation During the calibration phase, minimum and maximum effective sensor values were determined using percentile-based thresholds as expressed in Equation (3.3) and Equation (3.4): 𝑉min = 𝑃5 (𝑉) (3.3) 𝑉max = 𝑃95 (𝑉) (3.4) where 𝑉min is the minimum voltage obtained from the sensor, 𝑉max is the maximum voltage measured during calibration, and 𝑃5 (𝑉) and 𝑃95 (𝑉) denote the 5th and 95th percentile values, respectively, of the collected calibration samples 𝑉. The limits obtained from Equation (3.3) and Equation (3.4) allowed the game to adapt to each user’s strength range, avoiding sensitivity to outliers or transient spikes. 3.9.3 Normalization Mapping To convert the calibrated sensor readings into a standardized control parameter, each real-time voltage value was normalized between 0 and 1 using Equation (3.5): 𝑁= 𝑉 − 𝑉min 𝑉max − 𝑉min (3.5) where 𝑁 is the normalized value (dimensionless, between 0 and 1), 𝑉is the current sensor voltage, 𝑉min is the minimum reference voltage from Equation (3.3), and 𝑉max is the maximum reference 19 voltage from Equation (3.4). The normalized value obtained from Equation (3.5) served as a unified control signal for both character speed in the Forest Run game and arrow power in the Archery game, ensuring consistent behaviour across users. 3.9.4 Player Movement Speed (Forest Run) In the Forest Run mode, the normalized value was mapped to the player’s running speed using Equation (3.5): 𝑆 = 𝑁 × 10 (3.6) where 𝑆 is the running speed in meters per second and 𝑁 is the normalized sensor value from Equation (3.5). The speed obtained from Equation (3.6) directly linked the user’s exerted effort to the virtual running speed, thereby encouraging active participation. To represent motion on the display, the physical speed was converted into pixels per second using Equation (3.7): 𝑉pixel/sec = 𝑆 × 20 (3.7) where 𝑉pixel/sec is the speed expressed in screen pixels per second and the constant 20 corresponds to the number of pixels representing one meter in the game environment. The value from Equation (3.7) ensured that the on-screen movement remained visually proportional to the user’s physical input and consistent with the chosen spatial scaling. 3.9.5 Distance Computation (Forest Run) The total distance covered by the player during the game was obtained by accumulating the incremental distance travelled in each frame, as shown in Equation (3.8): 20 (3.8) 𝑑(𝑡) = ∑𝑆 ⋅ 𝑑𝑡 where 𝑑(𝑡) is the total distance at time 𝑡, 𝑆 is the instantaneous running speed from Equation (3.6), and 𝑑𝑡is the time interval between successive frames. The cumulative distance obtained from Equation (3.8) was used to provide quantitative feedback on user performance and to trigger reward placements at fixed intervals. 3.9.6 Release Detection (Archery) In the Archery mode, arrow release was detected by monitoring the change in normalized sensor value between consecutive readings, as defined in Equation (3.9): (3.9) Δ𝑁 = 𝑁(𝑡 − 1) − 𝑁(𝑡) where Δ𝑁 is the change in normalized load, 𝑁(𝑡) is the current normalized value, and 𝑁(𝑡 − 1) is the previous normalized value. A significant drop in Δ𝑁, obtained from Equation (3.9), indicated a rapid release of tension and was used as the trigger condition for firing the arrow, thereby emulating a realistic pull-and-release action. 3.9.7 Projectile Computation for Weak Shots For weak shots, the initial velocity of the arrow was resolved into horizontal and vertical components using Equation (3.11) and Equation (3.10): 𝑣𝑥 = 𝑣cos(𝜃) (3.10) 𝑣𝑦 = 𝑣sin(𝜃) (3.11) where 𝑣𝑥 and 𝑣𝑦 are the horizontal and vertical components of the arrow’s initial velocity, 𝑣 is the resultant initial speed, and 𝜃 is the launch angle with respect to the horizontal. 21 The effect of gravity on the arrow’s vertical motion was incorporated using Equation (3.12): 𝑣𝑦 (𝑡) = 𝑣𝑦 (𝑡 − 1) + 𝑔 ⋅ 𝑑𝑡 (3.12) where 𝑣𝑦 (𝑡) is the vertical velocity at time 𝑡, 𝑣𝑦 (𝑡 − 1) is the vertical velocity at the previous time step, 𝑔 is the gravitational acceleration used in the game, and 𝑑𝑡 is the frame time step. Together, the relations in Equation (3.10), Equation (3.11) and Equation (3.12) provided a realistic projectile trajectory for weak shots, enabling the simulation of arrows falling short or missing the target in the archery mode. 3.9.8 Velocity Estimation for Strong Shots For strong shots, a direct targeting approach was used to ensure that the arrow reached the centre of the target. The required constant horizontal and vertical velocities were calculated using Equation (3.13) and Equation (3.14): (𝑥target − 𝑥start ) 𝑡 (𝑦target − 𝑦start ) 𝑣𝑦 = 𝑡 𝑣𝑥 = (3.13) (3.14) where 𝑥target and 𝑦target are the coordinates of the target centre, 𝑥start and 𝑦start are the coordinates of the arrow’s starting position, 𝑡is the predefined travel time for a strong shot, and 𝑣𝑥 and 𝑣𝑦 are the corresponding horizontal and vertical velocity components. The velocities obtained from Equation (3.13) and Equation (3.14) ensured that, for sufficiently high pulling effort, the arrow consistently reached the bullseye, thereby providing clear positive reinforcement for maximal effort during rehabilitation. 22 3.10 GAME INTERFACE AND MAPPING LOGIC The game interface was designed to provide a smooth connection between real-time sensor input and gameplay behaviour. Figure 3.10 illustrates the overall mapping logic, starting from sensor acquisition, passing through game selection, and ending with mode-specific gameplay responses. The blocks represent key modules involved in the interface. Figure 3.10 The game-mapping logic flow The system begins with a real-time interface that continuously acquires live voltage from the serial input. This raw voltage is directly mapped to speed or force values in the game. The interface provides immediate feedback based on sensor interaction, enabling dynamic user control. Control is transferred to the main menu, where users can choose between available rehabilitation game modes. The main menu loads the background graphics, initializes window settings, and triggers sensor calibration routines before entering a selected game. Two game modes are provided: Forest Run and Archery. In the Archery module, the load-based logic shown in Figure 3.7 indicates how sensor input is categorized to generate interaction states such as pull, aim, and 23 release. Based on the level and rate of change of the sensor value, the system decides whether the user is preparing, aiming, or triggering an action. In the Forest Run module, the game continuously updates character speed, distance, score, and reward collection using data from the real-time interface. Similarly, in the Archery mode, sensor information controls animation sequences, arrow release, and scoring events. Both modes operate within a main loop, which handles periodic updates, visual display, and resetting of game states. 3.11 IMU-BASED GAME LOGIC AND INTEGRATION The IMU sensor output is used in the game by continuously monitoring the pitch angle of the user’s torso and comparing it with a predefined threshold. During initial calibration, an upright sitting position is recorded as the reference. In realtime gameplay, if the pitch angle remains above the threshold (within the acceptable upright range), the system interprets the posture as correct and allows the game to continue. However, if the pitch falls below the threshold, indicating a crouched or slouched posture, the system immediately restricts gameplay or removes the player from the game environment. This ensures that the user maintains proper posture throughout the exercise and prevents incorrect movement patterns. This posture-based control is integrated into the overall game logic to enhance safety and effectiveness. In the running game, the character continues moving only when the posture is correct, and score is awarded each time the character crosses 500 meters, encouraging sustained performance with proper alignment. In the archery game, posture validation ensures that the user remains upright while performing the action, and score is awarded when the arrow successfully hits the board. By linking posture directly with gameplay continuation and scoring, the IMU ensures that users not only engage with the game but also maintain correct biomechanics during rehabilitation. 24 CHAPTER 4 RESULTS AND DISCUSSION 4.1 INTEGRATION OF FSR Integration of FSR is explained in figure 4.1. The Force Sensitive Resistor (FSR) is connected to an ESP32 using a voltage divider circuit to measure its varying resistance as an analog voltage. The FSR has two terminals: one terminal is connected to the 3.3V output of the ESP32, while the other terminal is connected to both an external resistor and an analog-capable GPIO pin 34 on the ESP32. The external resistor, typically 10kΩ, is placed between the second terminal of the FSR and the ground (GND) of the ESP32. This configuration forms a voltage divider, where the voltage at the junction between the FSR and the resistor varies depending on the applied pressure. Figure 4.1 FSR sensor integration 25 4.1.1 CALIBRATION To calibrate the FSR, loading is begun from 100g on the FSR and recorded the response and started adding 100g one by one and recorded its response up to 1000g. Then the above process is shown in the figure 4.3 which is repeated for three trials and recorded the responses are mentioned in the table 4.1. Table 4.1 Response of FSR to different loads 5.0 VOLTAGE (V) LOAD (gm) TRIAL 1 TRIAL 2 TRIAL 3 AVERAGE 100 0.24 0.20 0.22 0.22 200 0.83 0.85 0.84 0.84 300 1.33 1.31 1.35 1.33 400 1.87 1.85 1.90 1.87 500 2.21 2.24 2.23 2.23 600 2.98 2.99 3.01 2.99 700 3.82 3.85 3.81 3.82 800 4.03 4.02 4.05 4.03 1000 4.99 4.95 4.97 4.97 26 Graphical representation of FSR response is given in Figure 4.2: Plot of Load(gm) vs Voltage(V) Figure 4.2 Graphical representation of the FSR response Figure.4.3 Calibration of FSR 27 An FSR is connected via wires to a breadboard, which interfaces with a microcontroller board placed on the table. The FSR appears to be loaded with a metal weight placed on top, providing a known, repeatable force for calibration 4.2 IMU-BASED POSTURE DETECTION Fig.4.4 Posture detection using IMU (Left- Crouched, Right- Upright) The IMU is used for posture detection by measuring the orientation of the user’s body through sensor fusion of accelerometer and gyroscope data, which provides pitch and roll angles. Among these, pitch is the primary parameter, representing forward and backward bending of the torso, while roll indicates side tilt and shows only minor variations. Based on calibration, a threshold is defined for posture classification, where pitch values below 80° indicate a crouched or slouched posture, and pitch values greater than or equal to 80° indicate an upright posture. Observations from the system show a clear distinction between these two conditions, making pitch a reliable parameter for posture detection. In the implemented system, this threshold-based approach is used to control the game, where the game continues 28 only when the user maintains an upright posture and pauses or exits when incorrect posture is detected, thereby ensuring safe and effective rehabilitation. 4.3 HARDWARE INTEGRATION USING BROWN BOARD (ESP32 + FSR + IMU) Fig.4.5 Brown Board Soldering The hardware of the system is integrated using a brown perfboard (generalpurpose PCB), where all components are securely mounted and soldered to form a compact and reliable circuit. The ESP32 microcontroller acts as the central processing unit and is soldered onto the board along with necessary connections for power and signal routing. Two FSR sensors are interfaced using a voltage divider configuration, with their outputs connected to the analog input pins of the ESP32 for force measurement. The wiring is carefully soldered on the underside of the board to ensure stable electrical connections and reduce noise or signal loss. This setup allows accurate acquisition of force data during rehabilitation exercises. In addition to the FSR integration, the IMU sensor is also connected to the ESP32, enabling posture monitoring within the same system. The combined setup ensures that both force (FSR) and posture (IMU) data are processed simultaneously by a single microcontroller. The entire circuit is powered through a battery source, making the system portable and suitable for real-time use. This compact integration 29 on a brown board eliminates the need for loose wiring, improves durability, and enables seamless wireless transmission of sensor data to the laptop for real-time game interaction. 4.4 SENSOR ATTACHMENT TO BAND To ensure accurate force and movement detection during upper-limb exercises, the FSR is securely integrated into the resistance band handle as shown in the figure 4.4. The FSR was positioned at the point of maximum grip contact so that any increase in pulling force translated directly into increased pressure on the sensor surface. This placement allowed the FSR to capture progressive resistance force generated during stretching of the band. The sensor was fixed firmly using non-slip adhesive and strapped to prevent displacement during use. Care was taken to ensure that the sensor did not affect the natural feel or elasticity of the resistance band. This arrangement ensured stable, repeatable readings and provided a reliable foundation for real-time game control and performance tracking. Figure 4.6 Sensor placement on resistance band 30 4.5.1 GAME – MAIN MENU INTERFACE The games begin with a user-friendly main menu, as shown in Figure 4.6. The interface displays the title “Rehabilitation Training” along with two selectable game modes: Forest Run and Bow & Arrow. This screen serves as the central navigation point for the user. The background environment consists of a forest landscape designed to provide a calming and visually engaging rehabilitation experience. The interface is intentionally simple to ensure easy interaction for patients of different age groups and cognitive abilities. Selecting the Forest Run option initiates the forcecontrolled running module, whereas the Bow & Arrow option opens the precisionbased upper-limb training game. Figure 4.7 Patient Login Interface 31 Figure 4.8 Main menu interface showing game mode selection 4.5.2 FOREST RUN – REAL-TIME GAME OUTPUT Figure 4.7 illustrates the live gameplay of the Forest Run module. The character’s speed, distance, load percentage, and time are displayed dynamically on the screen. These parameters are directly mapped to the real-time force applied on the resistance band through the FSR sensor. When the user pulls the band harder, the speed increases, the distance counter rises, and the load percentage reaches higher values. A live voltage bar on the right side of the screen visualizes the incoming force data, reinforcing real-time feedback. This setup creates an engaging rehabilitation environment in which the patient’s physical effort translates immediately into on-screen motion, encouraging consistent participation and improving muscle activation. 32 Figure 4.9 Forest Run game displaying real-time sensor-controlled character movement 4.5.3 BOW & ARROW GAME – REAL-TIME ARCHERY MODULE The Bow & Arrow game shown in the figure 4.8 provides a precision-based rehabilitation task, focusing on controlled force application and sustained muscle engagement. In this module, the user pulls the resistance band to simulate drawing a bow. The FSR sensor value is mapped to the draw strength, and the flex sensor helps monitor arm posture. As the user gradually increases the pulling force, the power meter on the screen fills proportionally. Releasing the band triggers the arrow’s release in the game. The arrow’s speed, trajectory, and accuracy depend on the force exerted and the stability of the movement during the draw. 33 This module helps patients practice controlled upper-limb movements, accuracy, coordination, and sustained muscle activation skills essential in functional rehabilitation. Figure 4.10 Bow & Arrow game illustrating force-controlled power meter and target shooting 4.6 SESSION DASHBOARD AND STORAGE The session dashboard in the rehabilitation game provides real-time visualization of patient performance by continuously displaying key parameters such as load percentage, voltage, score, time, repetitions, and game-specific metrics (distance in Forest Run and accuracy in Archery). It also includes a live scrolling effort graph that represents normalized sensor values over time, enabling immediate feedback on user exertion and consistency. Additionally, the dashboard integrates visual UI elements like load bars, posture alerts, reconnect overlays, and patient identification labels to ensure an interactive and safe rehabilitation experience. At 34 the end of each session, a dedicated summary screen presents consolidated performance metrics including total score, session duration, peak effort, and average effort, helping users and clinicians quickly assess performance. The system incorporates a structured data storage mechanism that records session details into patient-specific CSV files for long-term tracking and analysis. Each session entry includes parameters such as patient name, date, time, game mode, score, duration, peak load, average load, and number of repetitions, ensuring comprehensive documentation of rehabilitation progress. The data is automatically appended at the end of each session, with files organized per patient and mode to maintain clarity and accessibility. This storage approach enables easy retrieval for trend analysis, performance comparison, and clinical evaluation, thereby transforming the rehabilitation game into a data-driven therapeutic tool Figure 4.11 Dashboard after each session 35 4.7 FOREST RUN GAME - RESULT INTERPRETATION 1 Table 4.2 Subject Data – Forest run game SUBJECT AGE DISTANCE SCORE COVERED Subject 1 21 1500 300 2 Subject 2 20 1456 200 49.4% 3 Subject 3 29 1308 200 45.4% 4 Subject 4 21 1650 300 59.3% 5 Subject 5 22 1870 300 59.6% S.NO AVERAGE EFFORT 56.3% The results from the running game indicate a clear relationship between distance covered, score, and average effort. Subjects who maintained higher average effort percentages generally achieved greater distances and higher scores. For instance, Subject 5 recorded the highest distance (1870 m) along with a high effort (59.6%), while Subjects 1 and 4 also demonstrated strong performance with high scores (300) and effort levels above 56%. In contrast, Subjects 2 and 3 showed comparatively lower effort percentages, which is reflected in reduced distance and score outcomes. Overall, the data suggests that consistent force application, as measured by the FSR sensors, directly enhances performance in the running game, validating the effectiveness of the system in tracking effort-based rehabilitation. 4.8 BOW AND ARROW GAME – RESULT INTERPRETATION The bow and arrow game results highlight the relationship between number of repetitions, control, and scoring efficiency. Subjects who performed more repetitions with better control achieved higher scores, as seen in Subjects 4 and 5, who recorded the highest reps (15) and scores (13 and 14 respectively). Subjects 36 with fewer repetitions, such as Subjects 1 and 3, obtained lower scores, indicating reduced control or consistency during the task. S.NO Table 4.3 Subject Data – Bow and arrow game SUBJECT AGE REPS SCORE 1 Subject 1 21 10 7 2 Subject 2 20 12 8 3 Subject 3 29 9 7 4 Subject 4 21 15 13 5 Subject 5 22 15 14 This reflects the importance of sustained and controlled force application in achieving accurate shots. Overall, the results demonstrate that the system effectively captures user performance in terms of precision and consistency, making it suitable for assessing fine motor control and coordination during rehabilitation exercises. 4.9 PERFORMANCE IMPROVEMENT ACROSS TRIALS The trial-wise results for Subject 1 show a progressive improvement in both strength and control over time. In the running game, there is a steady increase in distance covered, score, and average effort, indicating enhanced force generation and endurance. Similarly, in the archery game, the number of repetitions and score improves across trials, reflecting better control, coordination, and consistency in force application. This improvement demonstrates the effectiveness of the system in providing real-time feedback and motivating gradual rehabilitation progress, confirming its suitability for tracking patient recovery over multiple sessions. 37 Table 4.4 Performance of a subject recorded over time TRIAL RUNNING RUNNING AVG ARCHERY ARCHERY DISTANCE (M) SCORE EFFORT (%) REPS SCORE Trial 1 900 100 42.5% 6 4 Trial 2 1150 200 48.2% 8 5 Trial 3 1350 200 52.6% 9 6 Trial 4 1500 300 56.3% 10 7 38 CHAPTER 5 CONCLUSION This project successfully developed a fully integrated, wireless upper-limb rehabilitation system that combines force sensing, posture correction, and real-time game-based feedback to enhance therapy effectiveness and user engagement. The system utilizes two FSR sensors to measure applied force and a IMU to ensure correct posture during exercises. By integrating all components into a single ESP32based embedded system on a custom soldered board, the design achieves portability, reliability, and real-time performance. The wireless transmission of sensor data and its seamless integration with a Unity-based game environment enables an interactive rehabilitation experience. The developed system effectively ensures that exercises are performed with proper posture and controlled force, improving safety and targeting the correct muscle groups. The implementation of two rehabilitation games, running and archery demonstrates how physical effort can be translated into meaningful game interactions, while scoring and graphical feedback motivate users to perform consistently. Additionally, features such as session-based data storage and real-time visualization support performance tracking and progress assessment. Overall, the project presents a low-cost, portable, and scalable rehabilitation solution with strong potential for future clinical applications and advanced enhancements. 39 REFERENCES 1. Samit Hasan, Tanvir Pantha, Muhammad Abdullah Arafat, “Design and development of a cost-effective portable IoT-enabled physiological signal monitoring system”, IEEE Access, Volume 7, June 2024, 100124 2. Mohammad Anvaripour, Mehrdad Saif, “Hand gesture recognition using force myography of the forearm activities and optimized features”, IEEE International conference on industrial technology, 2018, doi: 10.1109/ICIT.2018.8352174 3. Carina S Gonzalez, Pedro A. Toledo-Delgado, Vanesa Muñoz-Cruz, Pablo V. Torres-Carrion, “Serious games for rehabilitation: Gestural interaction in personalized gamified exercises through a recommender system”, Journal of Biomedical Informatics, Volume 97, September 2019, 103266 4. Franchino Porciuncula, Anna Virginia Roto, Deepak Kumar, Irene Davis, Serge Roy, Conor J Walsh, Louis N Awad, “Wearable Movement Sensors for Rehabilitation: A Focused Review of Technological and Clinical Advances”, Physical Medicine and Rehabilitation, 2018, doi: 10.1016/j.pmrj.2018.06.013 5. Hongliu Yu, Søren Kold, Ole Rahbek, Shaoping Bai, “Wearable sensors for activity monitoring and motion control: A review”, Biomimetic Intelligence and Robotics, Volume 3, Issue 1, March 2023, 100089 6. Aparajita Saraf, Seungwhan Moon, Andrea Madotto, “A Survey of Datasets, Applications, and Models for IMU Sensor Signals”, 2023 IEEE International Conference on Acoustics, Speech, and Signal Processing Workshops (ICASSPW), DOI: 10.1109/ICASSPW59220.2023.10193365 40 41
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )