By: Anurag Kumar Singh (8th Batch)
Experiment No. 7
Aim:To determine the burning Velocity of Gas/Air Mixtures Using the Cone Angle
Method
Apparatus:➢ Conical Burner Setup
➢ Gas Supply System
➢ Air Supply System
➢ Flow Meters
➢ Pressure Regulators
➢ Ignition System
➢ Thermocouples or Temperature Sensors
➢ High-speed Camera (optional)
➢ Data Acquisition System
➢ Safety Equipment (gloves, goggles, lab coat)
Chemicals Required:Gas sample
Principle –
The Cone Angle Method is a technique used to measure the burning velocity of
gas/air mixtures, which is an important parameter in combustion studies. The
burning velocity is the rate at which a flame propagates through a premixed gas
mixture, relative to the unburned gas. Understanding this velocity is crucial for
optimizing combustion processes, improving fuel efficiency, and reducing
emissions.
Principle of the Cone Angle Method:
1. Premixed Flame:
o A gas/air mixture is prepared in a controlled environment, ensuring
the mixture is homogeneous. This mixture is then ignited to form a
premixed flame.
2. Nozzle and Cone Flame:
o The gas/air mixture is allowed to exit through a nozzle, which shapes
the flame into a conical shape. The shape and angle of the flame cone
are influenced by the burning velocity of the mixture and the flow
rate of the unburned gases.
By: Anurag Kumar Singh (8th Batch)
3. Cone Angle:
o The angle of the flame cone, denoted as θ, is measured. The cone
angle is related to the balance between the velocity of the unburned
gases (coming from the nozzle) and the burning velocity of the
mixture.
4. Relationship Between Cone Angle and Burning Velocity:
o For a steady flame, the burning velocity SL is related to the flow
velocity u0 and the cone angle θ by the equation:
SL=u0 ⋅ sin(θ)
Here, u0 is the velocity of the unburned gas mixture as it exits the
nozzle.
5. Measurement Process:
o The flow rate of the unburned mixture is adjusted to achieve a stable
cone flame. The cone angle θ is measured using optical methods or
cameras. Knowing the flow rate u0 and the cone angle θ, the burning
velocity SL can be calculated.
o
Theory
Burning Velocity
The fundamental burning velocity (or laminar burning velocity) is the rate at
which a flame front propagates through a quiescent gas/air mixture. This
parameter is crucial for understanding combustion characteristics and designing
combustion systems.
Cone Angle Method
The Cone Angle Method involves burning a gas/air mixture at the tip of a conical
burner. The shape and size of the flame are used to calculate the burning velocity.
The key assumption is that the flame is stabilized at the burner tip, forming a
steady cone shape.
Formula
The burning velocity (Su) can be calculated using the relationship between the
mass flow rate, the flame area, and the flame angle (α):
Su = m˙/ ρAf
By: Anurag Kumar Singh (8th Batch)
Where:
m˙ = mass flow rate of the gas/air mixture (kg/s)
ρ = density of the gas/air mixture (kg/m³)
Af = flame surface area (m²), which can be calculated from the cone angle
For a conical flame: Af = π r2
And the radius (r) can be related to the cone angle (α) and the height (h) of the
flame:
r = h tan(α)
Combining these, the fundamental burning velocity (Su) is:
Su = m˙/ ρ π (h tan(α))2
Schematic Diagram
Procedure
Preparation
1. Ensure Safety:
o Wear appropriate safety equipment (gloves, goggles, lab coat).
o Check that all connections are secure and there are no leaks in the
gas supply system.
By: Anurag Kumar Singh (8th Batch)
2. Set Up the Burner:
o Assemble the conical burner and ensure it is firmly fixed.
o Connect the gas and air supply systems to the burner.
3. Calibrate Flow Meters:
o Calibrate the flow meters to ensure accurate measurement of gas and
air flow rates.
Measurement
1. Adjust Gas/Air Mixture:
o Adjust the flow rates of the gas and air to achieve the desired mixture
ratio.
o Use the flow meters to monitor the flow rates.
2. Ignite the Mixture:
o Use the ignition system to ignite the gas/air mixture at the burner tip.
o Adjust the flow rates to stabilize the flame at the burner tip, forming
a steady conical shape.
3. Measure Flame Parameters:
o Measure the height (h) of the conical flame using a ruler or highspeed camera.
o Measure the cone angle (α) using a protractor or high-speed camera.
4. Record Data:
o Record the flow rates of gas and air.
o Record the flame height (h) and cone angle (α).
Computations
1. Calculate Mass Flow Rate:
o Use the flow rates and gas properties to calculate the mass flow rate
(m˙).
2. Calculate Flame Surface Area:
o Calculate the radius (r) of the flame base using r = h tan(α)
2
o Calculate the flame surface area (Af = π r ).
3. Calculate Burning Velocity:
2
o Use the formula Su = m˙/ ρ π (htan(α)) to calculate the fundamental
burning velocity.
Data Analysis
1. Plot Results:
o Plot the burning velocity against different gas/air mixture ratios to
analyze the combustion characteristics.
2. Compare with Literature:
o Compare the experimental results with literature values to validate
the experiment.
By: Anurag Kumar Singh (8th Batch)
Observation Table:
SL.No
Calculations
Mass flow rate of LPG
m3/s
Angle between the axis of flame
and slant height (α)
By: Anurag Kumar Singh (8th Batch)
Precautions
1. Handle gases with care and ensure proper ventilation in the lab.
2. Avoid leaks in the gas supply system by regularly checking connections.
3. Ensure stable flame conditions to get accurate measurements.
4. Regularly calibrate instruments for precise measurements.
Result:
The burning Velocity of Gas/Air Mixtures Using the Cone Angle Method is
observed as ………………………….