Candidate Number: 1095140 Numerical Simulation and Optimization of Dispersive Readout Parameters in Superconducting Qubits Abstract: Single-shot dispersive readout of superconducting transmon qubits under T1 decay and leakage to the second excited state was numerically simulated using LeeQ. Physical qubit parameters were taken from OXF Q4 in the Oxford Qubits dataset. By sweeping integration time, fidelity was found to increase quickly with longer integration times until peaking around 97% at t = 0.60 μs before declining due to T1-induced state misassignment. By sweeping readout amplitude at t = 0.60 μs, fidelity steadily increased with higher amplitudes until a T1-limited plateau was reached. Importantly, the signal-to-noise ratio was found to be a poor predictor of readout fidelity as SNR remained high even when fidelity degraded. 1. Introduction: Superconducting transmon qubits are one of the most promising candidates for quantum computing [1]. Readout fidelity---the accuracy of measuring a qubit state---is one of the characteristic indicators of device performance. The standard measurement process is single-shot dispersive measurement, in which qubits are coupled to resonators. The resonant frequency is state-dependent and hence encodes the qubit state [2]. The inphase (I) and quadrature (Q) components of this frequency signal form distinct clusters in the IQ plane for each state, and state assignment is performed by classifying which cluster a given measurement falls into. The fidelity of this dispersive measurement is fundamentally limited by physical processes of the device, and so readout parameters must be optimized to mitigate these limitations. Two primary sources of physical readout error were considered in this work: energy relaxation and leakage to higher states. Energy relaxation during the measurement window causes the qubit to decay from |1⟩ to |0⟩ before the resonator has been measured, resulting in asymmetric state misassignment. Leakage to the second excited state |2⟩ produces a third IQ cluster that the binary classifier cannot correctly distinguish. Leakage can be caused by multiple factors such as weak anharmonicity and high readout amplitudes, but in this work, we only consider leakage due to imperfect gate calibration. For energy relaxation, higher integration times cause more decay and therefore increased error. However, higher integration times also allow for more information to be collected, Candidate Number: 1095140 increasing signal-to-noise ratio and fidelity. Leakage population cascades through |2⟩→|1⟩→|0⟩ on a timescale set by the Jaynes-Cummings relaxation rate, further complicating optimal readout time scales. These three effects must be balanced to find the optimal integration time that returns maximal fidelity [3,4]. In this report, single-shot dispersive measurements that integrate these three effects were numerically simulated using LeeQ, an open-source quantum device simulation framework [5]. The physical qubit parameters were taken from the OXF Q4 device in the Oxford Qubits dataset [6]. The optimal integration time and readout amplitude were identified by sweeping each parameter independently and evaluating readout fidelity with a Gaussian Mixture Model (GMM) classifier. Section 2 describes the simulation method, Section 3 presents the results of each parameter sweep, and Section 4 concludes and discusses further directions of research. 2. Methods The simulation was implemented using LeeQ, with the following qubit parameters: qubit frequency 5040.4 MHz, anharmonicity −198 MHz, T1 = 12 µs, T2 = 26 µs, readout frequency 9645.4 MHz, resonator linewidth κ = 9.42 MHz, and dispersive shift χ = −4.08 MHz. A VirtualTransmon object was initialized with a specified quiescent state distribution, from which the resonator's IQ response was computed via the dispersive approximation. The resonator response for state |n⟩ is displaced in the IQ plane by nχ relative to the |0⟩ response, so |1⟩ and |2⟩ should produce distinct clusters separated from ground cluster by χ and 2χ respectively. A fixed Gaussian noise with initial standard deviation σ = 0.2 at a reference integration time of t = 1 µs was added to each IQ point, independent of readout amplitude and reduced by integration averaging as σ/√t. This reflected the physical reality that the noise floor is set by irreducible, physical sources rather than by readout parameters. The signal amplitude was modeled with resonator ring-up dynamics, scaling as amp × (1 − exp(−t/τ)), where τ = 1/κ is the ring-up time reflecting physical build-up of the field. State population dynamics during integration were modeled analytically: for the ground state |0⟩, the population is static and for the excited state |1⟩, T1 decay gives: 𝑡 𝑡 (1) ] , 𝑝0 (𝑡) = 1 − exp [− ] 𝑇1 𝑇1 For a state initialized in |2⟩, the cascade |2⟩→|1⟩→|0⟩ was solved analytically under relaxation rates 1/T1₂₁ and 1/T1, where T1₂₁ = T1/2 following the Jaynes-Cummings n+1 scaling. The results of solving the corresponding system of three coupled first-order ODEs with 𝑝0 (0) = 𝑝1 (0) = 0: 𝑝1 (𝑡) = exp [− Candidate Number: 1095140 𝑝2 (𝑡) = exp [− 𝑡 ] 𝑇21 (2) 𝑇1 𝑡 𝑡 ) (exp [− ] − exp [− ]) 𝑇1 − 𝑇21 𝑇21 𝑇1 (3) 𝑝0 (𝑡) = 1 − 𝑝1 (𝑡) − 𝑝2 (𝑡) (4) 𝑝1 (𝑡) = ( A realistic excited state preparation with leakage fraction ε was modelled as a mixture of (1−ε)|1⟩ and ε|2⟩, with both components evolving independently under equations (1) – (4) and their populations superposed. Given an input integration time and readout amplitude, single-shot IQ points were generated. Qubit states were sampled from the population distribution, with the corresponding resonator response computed and complex Gaussian noise added. For the main IQ cloud and GMM classification, 3000 shots per state were generated. State classification was performed using a two-component GMM fitted to the combined |0⟩ and |1⟩ IQ data, with assignments mapped to physical states by majority vote. Readout fidelity was defined as the average of the individual state assignment accuracies: 𝐹= 𝐹0 + 𝐹1 2 (5) where F₀ and F₁ are the fractions of |0⟩ and |1⟩ shots correctly classified respectively. Two parameter sweeps were performed: integration time from 0.05 to 10 µs and readout amplitude from 0.1 to 5.0 a.u., each with 2000 shots per state per sweep point. 3. Results Figure 1 shows the main IQ clouds generated for the ground state |0⟩ and excited state |1⟩ with optimal parameters of integration time t = 0.6 µs and readout amplitude amp = 2.0, with a leakage fraction of 5%. The two clusters are visibly separated in the IQ plane, with the |1⟩ cloud notably more spread than |0⟩ due to T1 decay during integration, which causes shots to drift toward the |0⟩ centroid. The three-state IQ cloud shown in figure 2 additionally shows the |2⟩ cluster displaced further from |1⟩ in the IQ plane, though the equal spacing predicted by shift scaling nχ is disrupted by |2⟩ cascade decay. Candidate Number: 1095140 FIG. 1. IQ Clouds after GMM classification corresponding to 3000 shots at t = 0.6 µs and amp = 2.0 FIG. 2. IQ Clouds before GMM classification corresponding to 3000 shots at t = 0.6 µs and amp = 2.0 The corresponding confusion matrix in figure 3 gives an average readout fidelity of 97.2%, with |0⟩ assigned correctly in 99.4% of shots but |1⟩ in only 95.0%, reflecting the asymmetric effect of T1 decay and leakage on the excited state. The 157 misassigned |1⟩ shots in figure 3 are consistent with a fraction of excited state population energetically relaxing to |0⟩ before measurement, combined with a small contribution from leaked |2⟩ population cascading through |1⟩ to |0⟩. The |0⟩ state is unaffected by either process, explaining the near-perfect |0⟩ assignment fidelity. FIG. 3. Confusion matrix corresponding to 3000 shots at t = 0.6 µs and amp = 2.0 Figure 4 shows readout fidelity as a function of integration time. Fidelity rises steeply at short times as the resonator signal builds up faster than T1 decay accumulates, reaching a peak of 97.2% at t = 0.60 µs. Beyond this point fidelity declines as T1-induced misassignment increasingly dominates, falling to ~72% by t = 10 µs. The SNR curve in Candidate Number: 1095140 figure 5 peaks much later at t = 8 µs and does not reflect the degradation in classification, demonstrating that SNR is a poor predictor of fidelity when T1 decay is significant. FIG. 4. Fidelity vs Integration Time at amp = 2.0 indicating maximum fidelity of 97% at integration time t = 0.6 µs FIG. 5. SNR vs Integration Time at amp = 2.0 indicating maximum SNR of 10 at integration time t = 8.0 µs Figure 6 shows readout fidelity as a function of readout amplitude at the optimal integration time t = 0.60 µs. Fidelity rises steeply from ~60% at low amplitude, where the signal is noise-dominated, and saturates at approximately 97% beyond amp = 1.5 a.u. Beyond this point, additional drive power yields no improvement since the noise floor becomes negligible and the remaining infidelity is entirely T1-limited. As shown in figure 7, SNR continues to rise even after the fidelity saturation amplitude, further confirming that SNR and fidelity decorrelate. FIG. 6. Fidelity vs Readout Amplitude with t = 0.6 µs demonstrating saturation at 97% beyond amp = 1.5 FIG. 7. SNR vs Readout Amplitude with t = 0.6 µs demonstrating continuous increase with no plateau Candidate Number: 1095140 4. Conclusion This report numerically simulated single-shot dispersive readout of a transmon qubit under T1 decay and leakage using LeeQ, integrating parameters from the OXF Q4 device. Readout fidelity was evaluated via a Gaussian Mixture Model classifier as a function of integration time and readout amplitude. An optimal integration time of t = 0.60 µs was found, which corresponds to a maximal fidelity value of 97.2%. This arose from the tradeoff between signal build-up at short times and T1 induced state misassignment at longer times. Sweeping readout amplitude confirmed that fidelity saturates beyond approximately 1.5 a.u., with the remaining infidelity being limited by T1 decay rather than noise. Additionally, SNR was found to be a poor predictor of readout fidelity, remaining high even as fidelity degraded at long integration times and readout amplitudes. Future work could extend the simulation to include dephasing dependent on cavity photon number, which becomes significant at high readout amplitudes and would create an upper bound on the amplitude sweep [7]. A three-component GMM classifier explicitly accounting for the |2⟩ cluster could also be implemented to recover fidelity lost to leakage misassignment, and optimal readout parameters could be re-evaluated under this more accurate classification method. References [1] P. Krantz, M. Kjaergaard, F. Yan, T. P. Orlando, S. Gustavsson, and W. D. Oliver, Appl. Phys. Rev. 6, 021318 (2019). https://doi.org/10.1063/1.5089550 [2] A. Blais, R.-S. Huang, A. Wallraff, S. M. Girvin, and R. J. Schoelkopf, Phys. Rev. A 69, 062320 (2004). https://doi.org/10.1103/PhysRevA.69.062320 [3] J. Gambetta, W. A. Braff, A. Wallraff, S. M. Girvin, and R. J. Schoelkopf, Phys. Rev. A 76, 012325 (2007). https://doi.org/10.1103/PhysRevA.76.012325 [4] Walter, et al., Appl. Phys. Rev. 7, 054020 (2017) doi.org/10.1103/PhysRevApplied.7.054020 [5] S. Cao, LeeQ (2024), GitHub repository, https://github.com/ShuxiangCao/LeeQ [6] S. Cao et al., arXiv:2402.09532 (2024). https://arxiv.org/abs/2402.09532 [7] J. Gambettaet al., Phys. Rev. A 74, 042318 (2006). https://doi.org/10.1103/PhysRevA.74.042318
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )