CENTRIFUGAL PUMPS FOR PETROLEUM, PETROCHEMICAL, AND NATURAL GAS INDUSTRIES
Table 9
59
Vibration Limits for Vertically Suspended Pumps
Location of Vibration Measurement
Pump thrust bearing housing or
motor mounting flange
(see Figure 33)
Criteria
Pump shaft
(adjacent to bearing)
Pump Bearing Type
All
Hydrodynamic guide bearing adjacent
to accessible region of shaft
Vibration at Any Flow Within the Pump s Preferred Operating Region
Overall
vu
0.20 in./s RMS
( 5.0 mm/s RMS)
Au < (10,000/n)0.5 mils peak-to-peak
(6.2
106/n)0.5 µm peak-to-peak
Not to exceed:
Au 4.0 mils peak-to-peak
(100 µm peak-to-peak)
Discrete frequencies
vf 0.13 in./s RMS
(3.4 mm/s RMS)
Allowable increase in vibration at
flows outside the preferred operating
region but within the allowable
operating region
30 %
For f
n: Af
0.33Au
30 %
Vibration velocity and amplitude values calculated from the basic limits shall be rounded off to two significant figures,
where
vu
is the measured overall velocity;
vf
is the discrete frequency velocity;
Au
is the amplitude of measured overall displacement;
Af
is the amplitude of displacement at discrete frequencies, measured with a FFT spectrum using a Hanning window and a
minimum frequency resolution of 400 lines;
n
is the rotational speed, expressed in r/min.
6.9.4.7 At any speed greater than the maximum continuous speed, up to and including the trip speed of the
driver, the vibration shall not exceed 150 % of the maximum value recorded at the maximum continuous speed.
Vibration exceeding this limit, but below the allowable limit in the table may be accepted with p
approval.
6.9.4.8 Variable-speed pumps shall operate over their specified speed range without exceeding the vibration
limits of this standard.
6.9.4.9
If the vendor can demonstrate that electrical or mechanical runout is present, the demonstrated amount
of runout can be vectorially subtracted from the measured vibration during the factory test as long as it does not
exceed 25 % of the allowed peak-to-peak vibration amplitude or 0.25 mil (6.5 µm), whichever is less.
60
API STANDARD 610
Key
X
rotational speed, n expressed in revolutions per minute
Y1 vibrational velocity, vu expressed in millimeters per second, RMS
Y2 vibrational velocity, vu expressed in inches per second, RMS
1
2
P 3000 kW/stage
P = 2000 kW/stage
3
4
P = 1500 kW/stage
P = 1000 kW/stage
5
6
P = 700 kW/stage
P = 500 kW/stage
7
P
300 kW/stage
NOTE 1
The equation for transition from 3.0 mm/s to 4.5 mm/s is: vu
NOTE 2
The allowable vibration limit for discrete frequencies is: vf
Figure 35
3.0 n 3600
0.30
P 300
0.21
.
0.67vu from Figure 35.
Bearing Housing Vibration Limits for Horizontal Pumps Running Above 3600 r/min or
Absorbing More Than 400 hp (300 kW) per Stage
6.10 Bearings and Bearing Housings
Bearings
6.10.1.1 Each shaft shall be supported by two radial bearings and one double-acting axial (thrust) bearing. If
the pump has rolling-element radial and thrust bearings, the thrust bearing carries both the radial load on one
end of the rotor and the axial thrust transmitted by the pump to the rotor. If the pump has hydrodynamic radial
bearings and a rolling-element thrust bearing, the rolling-element bearing carries axial thrust only; the
hydrodynamic bearings carry only radial loads. For higher loads and/or speeds, the hydrodynamic radial
bearings carry all the radial loads and the hydrodynamic thrust bearing carries all the axial load.