Power Generation Enhancement Using Hybrid Thermoelectric Generator with Synthetic Oil Based Nanofluids George Samuel Raj Va, Godson Asirvatham Lazarusa*, Elangovan Daniela, Anitha Angeline Appaduraib and Stephen Manovaa a Department of Mechancial Engineering, Karunya Institute of Technology and Sciences, Coimbatore -641114,India bDepartment of Electrical and Electronics Engineering, Karunya Institute of Technology and Sciences, Coimbatore -641114,India * Corresponding author e-mail : godson@karunya.edu, godsonasirvatham@gmail.com Abstract Power generation enhancement of hybrid thermoelectric generator (TEG) using the synthetic oil (Therminol 55) and a small volume concentration of Al2O3 nanoparticles (0.05 % and 0.1%) is experimentally studied. The hot side of the hybrid TEG is varied from 150°C to 380°C and load resistance up to 2 ohms respectively, while the cold side temperature is kept constant at 30 OC. The effect of hot side temperature and load resistance on the power generation is experimentally analyzed. The experimental results showed that the use of single hybrid TEG gave a power output of about 9.262 W with a temperature difference of 350 °C between hot and cold sides when using Therminol 55. By adding a small amount of Al2O3 nanoparticles to Therminol 55 the heat transfer capacity has increased and resulted in the enhancement of power output to 13.2 W for 0.05% concentration and 19.22 W for 0.1 % concentration for the same temperature difference. Also, the use of nanoparticles resulted in increasing the efficiency of the hybrid TEG system. An enhancement of 2.65% is observed in the power output when nanoparticles suspended synthetic oil and used as the hot side fluid. Keywords: hybrid thermoelectric generator, nanofluid, load resistance, synthetic oil, Therminol 55, power output 1. Introduction Consumption of fossil fuels by human activities leads to serious environmental problems. As a consequence, climate change, ozone layer depletion, greenhouse gas emission, global warming and acid rain terminologies have started to appear commonly in the literature. To reduce the effect of the above-mentioned disasters, the thermoelectric (TE) energy converters is proposed as one possible method which gains popularity as it has an ability to convert exhaust heat from vehicles, electrical equipments, etc., into the electricity.85% of world's energy is non-renewable energy resources in which 68% of fossil fuels are used in the generation of electric power [1]. Institute of Sustainable Energy Policies predicted that only 33% of non-renewable energy will exist for power generation in the year of 2050, whereas 67% will be substituted by renewable energy [2]. Thermoelectric generators which are semiconductor devices converts heat energy into electrical energy [3]. Payal et al [4] stated that the TEG module conveys 1.7 W of intensity, when hot side temperature was maintained at 75°C and cool side at 30°C which is likeness about 1.4% of effectiveness on a normal temperature contrast of60°C. The nano heat transfer fluid comprising Al2O3-Therminol 55 of volumetric proportions ranging from 0.025 vol% to 0.3 vol% have been characterized and evaluated as directly solar absorbing working fluid. Muraleedharan et al [5] experimented and found that the thermal efficiency of the solar collector has been increased with the nanoparticles attaining a maximum of 62% for 0.1% vol concentration. Quasim et al [6] reviewed that in automobile field the maximum efficiency achieved by TEG is 5% and TEG which is made up of Be2Te3 is used automobile industry. Changwei et al [7] experimentally found that the efficiency of the TEG system reached 4.5% with a temperature difference of 65 °C and in this study the cost of the TEG system is low when compared to wind power system and PV and experimentally connected 600 thermoelectric modules in series with a temperature difference of 120°C and the power reached 1 kW. Jun et al [8] conducted experiments in Multi stage thermo electric module (PbTe/Be2Te3) which resulted in 9.5% maximum efficiency in the temperature range of 303 to 923 K. Shiho Kim [9] derived an analytical model for the description of interior temperature difference as a function of the load current of a TEG. Godson et al [10] stated that the nanofluids have substantial capacity to enhance heat transfer. Thermoelectric generation technology which is a solid-state energy conversion method, can transform thermal energy into electricity by using thermoelectric transformation materials. A thermoelectric generator has some advantages such as no moving parts, compact size and highly reliable. Thus, this system can be simplified and functioned over a prolonged period of time with less maintenance cost. Moreover, it has a wider choice of thermal sources that utilize both the high and low-quality heat to generate electricity. 2. Experimental Method 2.1. Preparation of Nanofluids Two step method is used to prepare Therminol 55 - Al2O3 nanofluid. The average size of Al2O3 nanoparticle is noted to be less than 50 nm. The Al2O3 nanoparticle was distinguished by scanning electron microscope (SEM, JSM 6390, JEOL, USA) to study the particle size and shape. Fig 1 SEM image of Al2O3nanoparticle Fig 1 shows SEM image of Al2O3 nanoparticle taken at 300X magnification. To stabilize the Al2O3nanoparticles in the base fluid, required quantity (5% of each volume concentration) of surfactant Sodium dodecyl benzene sulfonate (SDBS) is added. Initially the surfactant is dispersed in to Therminol 55 and then required quantity of Al 2O3nano particles is added. Ultrasonic vibrator (Model: UP400S, Hielscher Ultrasound technology, Germany) is used to homogenize the mixture for 30 min to separate the agglomerates of Al2O3 nano particles. Therminol 55– Al2O3nanofluid were prepared with the volume concentrations of Al2O3 at 0.05% and 0.1 % for different samples. 2.2. Experimental Setup The performance of the thermo electric generator is experimentally studied in detail by developing a test rig which is shown in Fig 2. The components of test rig include: hybrid TEG, heat exchanger, heater, heat sink, electric load and data acquisition unit. The Hybrid Thermo Electric Generator (TEG) is placed between the two-copper block. One of the Copper blocks are fitted with cartridge heater with the capacity of 400 W to supply heat to hot side of TEG and another copper block which acts as a heat exchanger is placed on the cold side of TEG with water circulating inside the copper block. The heater is connected to the variac and varied for different Watts. A rheostat is connected to the hybrid TEG as an external load is to compute the output current and voltage through DC voltmeter and ammeter to obtain the power of the hybrid TEG and the time is noted down and the load resistance is varied correspondingly for different temperature difference. Thermo couple of type-T (micro) is used for tracking the temperature of hot and cold side of hybrid TEG, heater temperature and water inlet and water outlet temperature of the copper block placed on the cold side of hybrid TEG. Insulation is done using glass wool so that no heat goes to the surrounding. 2 1 Water Tank 8 1 Thermoelectric Generator 2 Heat Exchanger 3 Heat Source 4 Dimmerstat 5 Ammeter 6 Voltmeter 7 Rheostat 8 Data acquisition System 9 Laptop v 9 3 5 4 Thermocouple 5 6 6 7 Fig. 2 Experimental Test Rig 2.3 Calculation for Efficiency The efficiency of the thermoelectric module for power generation (ɳ) is calculated from the thermoelectric generator efficiency using the Equation (1) where, ɳ is the thermoelectric module efficiency, Pout is the output power, Qin is the heat load ɳ = Pout / Qin (1) The output power P is calculated as the product of output voltage and current as given in the equation (2) Pout= V X I (2) 3. Results and Discussion 3.1. Viscosity of Therminol 55 -Al2O3 Nanofluids 40 35 Viscosity (m Pa.S) 30 25 20 15 10 Therminol 55 Therminol 55/Al2O3 - 0.05% 5 Therminol 55/Al2O3 - 0.1% 0 0 10 20 30 40 50 60 70 80 Temperature (OC) Fig 3 Variation in viscosity with temperature for Therminol 55/Al2O3 nanofluid Figure 3 shows the viscosity variation with respect to temperature for various volume concentrations. It can be clearly noted that when the volume concentration is increased, there is an increase in viscosity of Therminol 55/Al2O3 nanofluid. However, viscosity decreases for increase in temperature. The viscosity of the Therminol 55/Al 2O3 nanofluid at 30 and 70 °C are 37.89 and 12.43 m Pa S, respectively, for 0.1% volume concentration with an increase of 21.9% and 54.06% when compared with that of Therminol 55. The main reason for increase in viscosity is the addition of the nano particles which increases the fluid friction and flow resistance [11]. The viscosity is measured using the Brookfield digital viscometer (DV-E, Brookfield, USA). 3.2. Surface Tension of Therminol 55 -Al2O3 Nanofluids 40 35 Surface Tension (mN/M) 30 25 20 15 Therminol 55 10 Therminol 55/Al2O3 - 0.05% 5 Therminol 55/Al2O3 - 0.1% 0 0 20 40 60 80 Temperature (OC) Fig 4 Variation in surface tension with temperature for Therminol 55/Al 2O3 nanofluid Figure 4 shows the comparison of surface tension with temperature for two different volume concentrations. It can be noted that the surface tension decreases when both the temperature and volume concentration of Therminol 55/Al 2O3 nanofluid increases. The surface tension of the Therminol 55/Al2O3 nanofluid at 30 °C and 70 °C are 31.28 and 24.52 mN/M, respectively, for 0.1% volume concentration, with a decrease of 13.81% and 15.82% when compared to Therminol 55. The inter-attractive forces of molecules weaken when the temperature is increased, resulting in a lower surface tension [11]. The measurement of surface tension was done by SITA dynotester (SITA Process Solutions, Germany) 3.3. Thermal Conductivity of Therminol 55 -Al2O3 Nanofluids 0.144 0.142 Thermal Conductivity (W/mK) 0.14 0.138 0.136 0.134 0.132 0.13 Therminol 55 Therminol 55/Al2O3 - 0.05% Therminol 55/Al2O3 - 0.1% 0.128 0.126 20 30 40 50 60 70 80 Temperature (OC) Fig 5 Variation in thermal conductivity with temperature for Therminol 55/Al2O3 nanofluid Figure 5 shows the comparison of thermal conductivity with temperature for various volume concentrations. It is clearly noted that the thermal conductivity of the working fluid decreases with an increase in both volume concentration and also for the base fluid. The values of thermal conductivity of the Therminol 55/Al 2O3 nanofluid at 30 °C and 70 °C are 0.1419 W/m K and 0.1372 W/m K respectively for 0.1% volume concentration, which are lower by 7.82% and 6.55 % when compared with that of Therminol 55. As the temperature increases, the solid nano particles experience a random motion and this movement obstructs transport of heat through liquids. Thus, with increase in temperature, the thermal conductivity of liquids decreases. The measurement of thermal conductivity was done by KD2 Pro (Decagon Devices, USA). 3.4. Temperature Difference and Power of Therminol 55 -Al2O3 Nanofluids Figure 6 shows variation in power generation with temperature difference of thermo electric generator for various volume concentrations Therminol 55/ Al2O3 nanofluid and is compared with Therminol 55. The highest temperature difference of TEG is noted for Therminol 55/ Al2O3 nanofluid whereas lowest value is noted for Therminol 55 (base fluid). In addition, increase in temperature difference enhances the power generation of TEG and 30% enhancement is noted when compared to the base fluid. The output power obtained for Therminol 55/ Al 2O3 nanofluid for ΔT = 25°C and ΔT =350°C are 0.25 W and 19.22 W respectively for 0.1% volume concentration. When nanoparticles are suspended in the base fluid, the heat absorbing capacity increases as thermal conductivity of Al 2O3 nanoparticles is high. Thus increase in thermal conductivity of nanofluid. 25 Therminol 55 Therminol 55/Al2O3 - 0.05% Power (W) 20 Therminol 55/Al2O3 - 0.1% 15 10 5 0 0 100 200 300 400 Temperature Difference (OC) Fig 6 Variation in power with temperature difference for Therminol 55/Al 2O3 nanofluid 3.5. Temperature Difference and Efficiency of Therminol 55 -Al2O3 Nanofluids Figure 7 shows the variation in thermal efficiency of the system for the base fluid and Therminol 55/Al 2O3 nanofluid with temperature difference of TEG. Increase in thermal efficiency is noted when the temperature difference increases. Volume concentration of 0.1% results in maximum thermal efficiency when compared to other concentration and the base fluid. The highest thermal efficiency is noted to be 2.36% for the maximum temperature difference of 350 °C. The addition of nano particles in the base fluid increases the heat transfer rate and thus enhancing the thermal efficiency of the proposed system. Moreover, the insulation using glass wool is done to ensure that no heat loss occurs to the surrounding. Thus, reducing the heat loss to the ambient increases the thermal efficiency. 3 2.5 Efficiency (%) 2 1.5 1 Therminol 55 0.5 Therminol 55/Al2O3 - 0.05% Therminol 55/Al2O3 - 0.1% 0 0 100 200 300 400 Temperature Difference (oC) Fig 7 Variation in efficiency with temperature difference for Therminol 55/Al 2O3 nanofluid 4. Conclusion According to the current study, the following preliminary conclusions may be drawn: 1. 2. 3. 4. Electricity has been produced using Hybrid TEG module and tested. The power could reach about 9.262 W with a temperature difference of about 350°Cbetween hot and cold sides for Therminol 55. By Adding Al2O3 nanoparticles to the Therminol 55 the heat transfer capacity has increased and resulted in increase in power and efficiency for 0.05% and 0.1% volume Concentration The efficiency of the TEG system reached 2.2% and the power produced is about 13.2 W for 0.05% concentration and temperature difference of 350 °C. The efficiency of the TEG system reached 2.65% and the power produced is about 19.22 W for 0.1% concentration and temperature difference of 350 °C. Acknowledgments The authors thankfully acknowledge the funding agency Department of Science and Technology (DST), Science and Engineering ResearchBoard (SERB), (SB/FTP/ETA-362/2012), India for providing the financial support. Also, the authors would like to thank Mr. Jayaseelan R of Karunya Institute of Technology and Sciences for helping in the fabrication of the experimental test facility. References: [1]. A.M. Omer, Energy, environment and sustainable development, Renew. Sustain. Energy Rev. 12 (2008) 2265–2300 [2]. M. Chan, Cutting carbon, improving health, The Lancet 374 (2009) 1870–1871. [3]. A.J.D. Peter, D. Balaji, D. Gowrishankar, Waste heat energy harvesting using thermoelectric generator, IOSR, J. Eng. 3 (2013) 1–4. [4]. Ms. Payal N. Ghusalikar, Mr. kunal S. Landge, Prof. P.V. Raut, Power Generation from Exhaust Gas and Engine Heat using TEG, International Research Journal of Engineering and Technology (IRJET),e-ISSN: 2395-0056 Volume: 06 Issue: 01 [5]. C. Liu, P. Chen, K. Li, A 1 kW low-temperature thermoelectric generator for low temperature geothermal resources, in: Proceedings, 39th Workshop on Geothermal Reservoir Engineering, Stanford University, Stanford, California, February 24–26, 2014. [6]. Mohd.Quasim Khan , S Malarmannan , G Manikandaraja, Power generation from waste heat of vehicle exhaust using thermo electric generator: A review, IOP Conf. Series: Materials Science and Engineering 402 (2018) 012174 [7]. Changwei Liu, Pingyun Chen, Kewen Li, A 1 kW Thermoelectric Generator for Low-temperature Geothermal Resources, Proceedings World Geothermal Congress 2015, Melbourne, Australia, 19-25 April 2015. [8]. Jun Pei ,LiangLiang Li, DaWei Liu, BoPing Zhang, Yu Xiao, JingFeng Li, Science China Technological Sciences, Volume 62, September 2019, Issue 9, pp 1596–1604. [9].Shiho Kim, Analysis and modeling of effective temperature differences and electrical parameters of thermoelectric generators, Applied Energy ,Volume 102, February 2013, Pages 1458-1463 [10]. Lazarus Godson, B. Raja, D. Mohan Lal , S. Wongwises , Enhancement of heat transfer using nanofluids—An overview, Renewable and Sustainable Energy Reviews 14 (2010) 629–641. [11] Nizar Ahammed, Lazarus Godson Asirvatham, Somchai Wongwises, Effect of volume concentration and temperature on viscosity and surface tension of graphene–water nanofluid for heat transfer applications, J Therm Anal Calorim (2016) 123:1399–1409.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )