3 PHASE INVERTER
PEIZHI XIA
THEOREM
DESIGN GOALS
• DC source: 200V DC (×2) or 400V DC
• Output: 3-phase AC Voltage, 110Vrms, 60Hz
• Switching Frequency: 100kHz
• Output ripple: <3% at peak voltage
• Nominal Power: 15kW for Resistor Load
PARAMETERS
• L = 500uH
• C = 10uF
• R = 2.42Ω
• L(load) = 4.8128mH (to match PF = 0.8 for inductive load)
•
𝑃𝐹 =
𝑅
𝑅 2 +𝑋𝐿2
=
𝑅
𝑅 2 +(2𝜋𝑓𝐿)2
• Sine wave Amplitude: 0.4033 (for sawtooth wave amplitude = 1)
• Sine wave bias: 0.5
• 𝑓𝑠𝑖𝑛 = 60𝐻𝑧, 𝑓𝑠𝑎𝑤 = 100𝑘𝐻𝑧
• 𝜑𝑎 = 0°, 𝜑𝑏 = 120°, 𝜑𝑐 = 240°
CIRCUIT DESIGN FOR R LOAD AND RL LOAD
Netural Line is not necessary for symmetric source and load, and simulation for directly 400V DC source will have similar result.
The introduction of Netural Line will make the circuit be able to deal with unsymmetric situation, however.
RESISTIVE LOAD
Current on Netural Line is less than 3A, much less than the
amplitude of working current (≈65A)
RESISTIVE LOAD
𝑉𝑝𝑘 = 155.2𝑉
𝐼𝑝𝑘 = 64.13𝐴
Power ≈ 15kW
Ripple ≈ 0.1V (<<3%)
PF = 1
Phase shift = 0
INDUCTIVE LOAD
The voltage ripple is very large at the beginning of the
simulation. It took approximately 0.1s to achieve stable
state.
The current variance is much smaller than the voltage
variance at the beginning of the simulation.
在此处键入公式。
The current on Neutral Line is small (<3A) except for the
beginning of the simulation (≈7.4A), much less than
working current (≈50A).
INDUCTIVE LOAD
Output Voltage and output current
INDUCTIVE LOAD
𝑉𝑝𝑘 = 152.02V
𝐼𝑝𝑘 = 50.27A
Power ≈ 9191W
Ripple ≈ 0.1V (<<3%)
PF ≈ 0.8
∆𝑇
Phase shift = 𝑇 × 360° = 36.53°
𝑐𝑜𝑠36.53° ≈ 0.8035
3 PHASE DIODE RECTIFIER THEOREM
CIRCUIT DESIGN FOR DIODE RECTIFIER LOAD
𝐴𝑑𝑗𝑢𝑠𝑒𝑚𝑒𝑛𝑡𝑠 𝑓𝑜𝑟 𝑐𝑜𝑛𝑣𝑒𝑟𝑡𝑒𝑟:
L = 50uH
C = 10mF
𝐷𝑖𝑜𝑑𝑒 𝑅𝑒𝑐𝑡𝑖𝑓𝑖𝑒𝑟 𝑃𝑎𝑟𝑎𝑚𝑒𝑡𝑒𝑟𝑠:
R = 4.167Ω
C = 20mF
DIODE RECTIFIER LOAD (AC VOLTAGE)
Wave Distorted, THD = 4.78%
V_peak ≈ 154.8V, almost no ripple
P_out ≈ 15.5kW
DIODE RECTIFIER LOAD (AC VOLTAGE AND CURRENT)
DIODE RECTIFIER LOAD (AC POWER)
DIODE RECTIFIER LOAD (DC VOLTAGE AND CURRENT)
V_out ≈ 250.5V
Output ripple ≈ 5V (2%)
SUMMARY
• For Resistive load and Inductive load, the 3-phase converter works properly and meets all requirements.
• There is still small current on neutral line.
• For Diode Rectifier load, the requirements are met, but the wave of output AC voltage is distorted.
• Some outcomes might swing during the simulation.
THANK YOU!