Project
Performance Analysis of a Reheat Rankine Cycle
Date: November 15, 2024
Prepared by: Alhussain Alhandhali
Course: Thermodynamics 2
Table of contents
1- Executive summary …………………………………………………….………………. 2
2- Introduction ……………………………………………………………………………...3
3- Methodology ……………………………………………………………………….…… 3
4- Results and Discussion ……………………………………………………………….… 4
5- Conclusions ……………………………………………………………….…………….. 8
6- References ………………………………………………………………….…………… 9
7- Appendix ………………………………………………………...…………………….. 10
Executive summary
The Reheat Rankine Cycle is an enhancement of the basic Rankine cycle used in steam power
plants to improve efficiency. Enhances power plants' thermal efficiency by reheating steam that
has partially expanded, which permits it to expand further and perform more work in the second
turbine stage while lowering moisture content. The report aims to describe the performance
analysis of a steam power plant using a reheat Rankine cycle. The main objective of the report is
to examine how changing boiler, condenser, and reheat pressures affected the cycle's net power
output and thermal efficiency. The analysis is carried out for different pressure and Using steam
property and thermodynamic calculations.
Introduction
One of the main global sources of electricity generation is steam power plants. The most popular
thermodynamic cycle for producing electricity using steam is the Rankine cycle. This cycle
produces work by heating water to create steam, which powers turbines. By warming steam in
between turbine stages, a reheat Rankine cycle increases the original Rankine cycle's efficiency.
This study aims to assess how different operating parameters, such as boiler pressure, condenser
pressure, and reheat pressure, affect a reheat Rankine cycle's performance. Through a parametric
analysis, this paper seeks to determine the ideal operating parameters that optimize thermal
efficiency and net power output.
Methodology
Using the spreadsheet for the steam properties and using Excel to do the calculations and the
plotting.
1-2 liquid from the condenser is pumped to the boiler (isentropic compression).
2-3 liquid enters the boiler at πππππππ and is heated to a high temperature of 800 C (constant-pressure heat addition).
3-4 steam expands isentropic in the high-pressure turbine (Isentropic expansion in turbine 1)
4-5 steam is reheated at constant pressure πβπππ‘ by the boiler to a high temperature again 800 C (constant-pressure
heat addition).
5-6 steam expands isentropic in the low-pressure turbine to πππππ (Isentropic expansion in turbine 2).
6-1 steam enters the condenser, where it is cooled and condensed (constant-pressure heat rejection)
For each state, steam properties such as enthalpy (h) and entropy (s) were obtained from steam tables or an
appropriate steam property calculator.
Calculation of the net power output and thermal efficiency.
The net power output:
πΎΜπππ = πΜ(πππ − ππππ )
πππ = (ππ − ππ ) + (ππ − ππ )
ππππ = (ππ − ππ )
Thermal efficiency:
πΌππ =
ππππ
πππ
Results and Discussion
a) schematic of the T-s diagram for the cycle
Figure 1: schematic of the T-s diagram for ideal Reheating Rankine the cycle
b) Effect on net power output: The quantity of work generated by the turbine and the amount
of work consumed by the pump affect the net power production. Then, Increasing the boiler
pressure raises the temperature at the turbine's input, which often raises the enthalpy drop
across the turbine and increases work production. As shown in Figure 2, as the boiler
pressure rises, the net power output increases.
αΊnet vs Pboiler
236000
234000
αΊnet
232000
230000
228000
226000
224000
222000
10000
12000
14000
16000
Pboiler
Figure 2: Plot of the net power output (αΊ net) against the boiler pressure
Effect on thermal efficiency: as the boiler pressure increases, the thermal efficiency of the
cycle increases, as shown in Figure 3. While the boiler pressure rises, the saturated
temperature of the water increases, which leads to higher thermal efficiency of the cycle
because heat transferred to the working fluid happens at a higher temperature.
ηth vs Pboiler.
0,494
0,492
0,49
ηth
0,488
0,486
0,484
0,482
0,48
10000
12000
14000
16000
Pboiler
Figure 3: Plot of the cycle thermal efficiency (ηth) against the boiler pressure
c) Effect on Net Power Output: The temperature and pressure of the steam leaving the lowpressure turbine drop as the condenser pressure drops, increasing the amount of work that
can be extracted in the turbine and raising the work output. Therefore, as we see in Figure
αΊnet
4, the increase in the condenser pressure leads to a decrease in the net power output.
αΊnet vs Pcond
230000
225000
220000
215000
210000
205000
200000
195000
190000
185000
180000
175000
10
30
50
70
Pcond
Figure 4: Plot of the cycle thermal efficiency (ηth) against the boiler pressure
Effect on thermal efficiency: Thermal efficiency is increased when condenser pressure is
reduced because it raises the average temperature of the Rankine cycle, as seen in Figure
5.
ηth vs Pcond
0,5
ηth
0,48
0,46
0,44
0,42
0,4
10
30
50
70
Pcond
Figure 5: Plot of the net power output (αΊnet) against the condenser pressure.
d) Effect on the net power output: For high reheat pressure, the net power output tends to
drop as the reheat pressure increases, as seen in Figure 6.
αΊnet vs Preheat
234000
232000
230000
αΊnet
228000
226000
224000
222000
220000
218000
216000
1500
2000
2500
3000
Preheat
Figure 6: Plot of the cycle thermal efficiency (ηth) against the preheated pressure.
Effect on the thermal efficiency: the trend starts to increase as the preheated pressure
increases, then it reaches its peak at pressure 2.5 Mpa, but the optimal balance between
power output and efficiency was achieved at reheat pressures of about 2 MPa, and after
that, the line drops noticeably. Increasing the preheat pressure to high pressure may cause
a loss of heat in the cycle and reduce the cycle efficiency.
ηth vs Preheat
0,488
ηth
0,4875
0,487
0,4865
0,486
0,4855
1500
2000
2500
3000
Preheat
Figure 7: Plot of the net power output (αΊnet) against the preheat pressure.
Conclusion
In conclusion, the reheat Rankine cycle's performance analysis revealed that changing the boiler,
condenser, and reheat pressures had a major effect on the cycle's net power output and thermal
efficiency. The ideal boiler pressure that has the maximum net power output and thermal efficiency
is the largest, while the condense pressure should kept as low as possible to maximize the net
power output and thermal efficiency. Furthermore, the optimal balance between power output and
efficiency was achieved at reheat pressures of about 2 MPa.
Reference
Çengel, Yunus A. (2008). Thermodynamics: an engineering approach. Boston:McGrawHill Higher Education,
Microsoft Corporation. (2018). Microsoft Excel. Retrieved from https://office.microsoft.com/excel
Appendix