Dynamic Slurry Pump Resistance Design Model Report
Pangasinan Tenement Areas
Phase densities
Primary mineral
Secondary phase contents
Fluid medium
5.20
1.80
1.03
Concentration, by volume
Percent primary per secondary
Percent solids per fluid medium
System efficient factors
Extraction efficiency
Separator efficiency
Mineral recovery rate
[-]
[-]
[-]
Schedule
Number of hours per day
Number of days per month
Number of off-hours per month
MT/m 3
MT/m 3
20%
15%
90%
98%
70%
Initial parameters
Ambient
Temperature
Pressure
[-]
[-]
Length References
Label
From
To
Depth (m)
H1
highest point
waterline
15.0
H2
surface point lowest point
30.0
H3
lowest point bed thickness
20.0
additional discharge length
dL
20.0
additional fitting losses
fL
0.0
Total length
85.0
MT/m 3
Depth
0
10
H1
20
30
H
2
40
50
20
30
120
60
H
3
70
Pump Parameter Map
25.0
10.3
Minerals and Material
Gross feed (target)
Pipe discharge diameter
Ore/grain size, d 50
Solids phase density
C
mH2O
2.48
Ore / grain size
1.25
MT/m3
mm
Slurry density
1.24
MT/m3
Limit settling coeffcieint
1.33
5000
550
1.25
3
m /hr
mm
mm
Pipe diameter
550
[-]
Critical limit velocity
5.20
mm
m/s
Pipe cross sectional area
0.238
m2
Limit flowrate (QL)
4450
Ambient pressure
120.0
10.3
450 mm
5000
mH2O
Ambient temperature
100.0
25.0
m3/hr
Target gross feed
m3/hr
Flow limit deviation for
settling (10% - 15%)
°C
80.0
11%
Pipe diameter size
60.0
40.0
550 mm
12.0
650 mm
10.0
OK
Static head (H1)
8.0
20.0
15.0
6.0
0.0
0
2000
4000
6000
8000
10000
5.3
8.8
5.0
4.0
450 mm
100.0
m
Total head loss
34.1
2.0
120.0
m
Balanced column loss
m
0.0
0
2000
4000
6000
8000
Head ratio
80.0
0.998
60.0
550 mm
40.0
650 mm
20.0
[-]
Equivalent water head
34.2
m
Estimated motive power
948
0.0
0
2000
4000
6000
8000
kW
10000
Summary:
1. For a 5000 cmh pump, the design total head should be at least 34.1 m with motive power of 948 kW (minimum)
2. For the motive power, electrical power should be at least 1.5 the minimum; for hydraulic power it should be at least 2.0
the minimum.
NJ Engineering Partner - Confidential
[1 / 1]