GET 205: Fundamentals of Fluid Mechanics
Lecture 5: Flow Measurement in Pipes
(J.T. Adeoye)
I. Introduction to Flow Measurement
The accurate measurement of volumetric flow rate
and mass flow rate
is critical in
almost all engineering disciplines. Flow measurement devices generally introduce some form of
obstruction or disturbance into the flow path and measure the resulting change in pressure,
velocity, or momentum.
The fundamental principle governing many common pipe flow meters is the Bernoulli Equation
combined with the Continuity Equation.
1. Continuity Equation:
○ This shows that velocity increases as the cross-sectional area decreases.
2. Bernoulli Equation (Ideal, Incompressible Flow):
○ For horizontal pipe flow,
○ As velocity (
.
) increases at the obstruction (due to
), the static pressure (
) must decrease to conserve energy.
○ By measuring the pressure drop
, we can infer the velocity and,
subsequently, the flow rate.
II. Obstruction Flowmeters (Differential Pressure Meters)
These devices use an abrupt or gradual change in pipe diameter to create a pressure difference,
which is then used to calculate the flow rate.
II.1. Theoretical Derivation of the Ideal Flow Rate
The flow rate equation for obstruction meters (Venturi, Orifice) is derived by applying the
Continuity and Bernoulli equations between the upstream section and the throat/vena contracta.
Assumptions for Ideal Flow:
1. Incompressible, inviscid (i.e. no viscous friction), steady flow.
2. Horizontal pipe (
).
3. Uniform velocity profiles at wide and narrow.
Derivation:
Bernoulli's Equation (Ideal):
Rearrange to Isolate Velocity Terms:
Continuity Equation:
The area ratio is
Substitute
into the Bernoulli result:
is an ideal velocity, hence we rewrite it as
Solve for Ideal Velocity (
):
Calculate Ideal Flow Rate (
):
Introduce Discharge Coefficient (
): To account for non-ideal effects (viscous losses,
non-uniform velocity, and the vena contracta location), the actual flow rate is introduced using
the empirical coefficient
.
A. The Orifice Meter
The orifice meter is the simplest and most common type of differential pressure flowmeter. It
consists of a sharp-edged, flat plate with a central hole (the orifice) inserted into the pipe.
Principle: When the fluid passes through the orifice, the velocity increases significantly, and the
pressure drops.
Vena Contracta: The point of minimum flow area and maximum velocity occurs downstream of
the physical orifice plate at a point called the vena contracta.
Flow Rate Equation (General Form):
Where:
is the actual volumetric flow rate.
is the measured pressure difference.
is the area of the orifice opening.
is the fluid density.
is the diameter ratio (orifice diameter
to pipe diameter
).
is the Discharge Coefficient. This is an empirical coefficient that accounts for
viscous and non-ideal effects, including the vena contracta. For sharp-edged orifices,
.
B. The Venturi Meter
The Venturi meter uses a smooth, gradually converging section to accelerate the flow and a
gradually diverging section to decelerate it.
Principle: The pressure drop occurs in the converging section, and much of the static pressure is
recovered in the diverging section (the diffuser).
Advantages:
1. Lower permanent (irrecoverable) pressure loss compared to the orifice plate due to
the gradual transitions.
2. Less susceptible to erosion and fluid build-up.
Disadvantages: More expensive and physically larger than an orifice plate.
Discharge Coefficient (
): Due to the gradual transition, flow separation is minimized, leading
to a higher, more consistent
(typically
to
).
Flow Rate Equation: The same general form as the orifice meter is used, but with the higher
value.
C. The Flow Nozzle
The flow nozzle is intermediate between the orifice and the Venturi meter. It has a smooth,
curved inlet and a sudden exit (no diffuser).
Characteristics: Higher permanent pressure loss than the Venturi, but lower than the orifice.
Smaller than the Venturi, but larger than the orifice.
and Venturi (
to
is generally between that of the orifice
).
III. Other Flow Measurement Devices
A. Pitot-Static Tube
This device measures the local velocity ( ) at a specific point in the flow by measuring the
difference between the stagnation (total) pressure (
) and the static pressure ( ).
Velocity Calculation: Based on Bernoulli's equation, the local (centerline) velocity is:
Flow Rate ( ): To find the volumetric flow rate, the local velocity must be integrated over the
entire cross-sectional area of the pipe. This usually requires traversing the tube or assuming a
standard velocity profile (e.g.,
for turbulent pipe flow).
B. Rotameter (Variable Area Flowmeter)
A vertical tapered tube containing a free-moving float. The float rises until the pressure
difference across the float, combined with the buoyant force, balances the float's weight.
Principle: The area of the flow passage changes with the height of the float.
Measurement: The height of the float in the tube is directly correlated to the flow rate.
IV. Example Problems
A. Orifice Meter Example
Water (
) flows through a horizontal pipe with a diameter
orifice meter with a diameter
is installed. A differential pressure transducer reads a
pressure drop
. Assume a discharge coefficient
the volumetric flow rate
. An
. Calculate
.
Solution:
Calculate Area
and Diameter Ratio
Calculate the term
:
:
Apply the Flow Rate Equation:
B. Pitot-Static Tube Example
Air (
) flows through a circular duct with a diameter of
.A
Pitot-Static tube placed at the center (where velocity is maximum) measures a differential
pressure head of
in the duct, assuming
of water (
). Estimate the volumetric flow rate
.
Solution:
Convert Differential Head to Pressure Difference (
The manometer reading gives the pressure difference
Calculate Centerline Velocity (
):
.
):
Use the Pitot-Static formula with the pressure difference and the fluid density (air).
Estimate Average Velocity (
):
Using the assumption for turbulent pipe flow:
Calculate Volumetric Flow Rate ( ):
First, find the pipe area
.
Some key takeaways
● Ideal vs. Actual Flow: Real flow measurement requires a Discharge Coefficient (
to account for real fluid effects (viscosity, turbulence, non-uniform velocity profiles).
● Trade-offs: Orifice plates are cheap but cause high permanent pressure loss. Venturi
meters are expensive but cause low permanent pressure loss.
● Pitot Tube Limitation: The Pitot tube measures local velocity; calculating total flow
requires integration over the pipe cross-section or empirical correction factors.
)