< Series 500+-A
MAINTENANCE MANUAL
B-64805EN/03
© FANUC CORPORATION, 2024
Important information
B-64805EN/03
Important information
No part of this manual may be reproduced in any form.
The appearance and specifications of this product are subject to change without notice.
Any copyright and other intellectual property rights regarding this manual shall belong to FANUC.
The safety precautions described in this manual may no longer be accurate and up-to-date due to revisions or
changes in laws and regulations. Before using our products, each user must confirm the latest laws and
regulations.
The products in this manual are controlled based on Japan's “Foreign Exchange and Foreign Trade Law". The export of
Series 500i from Japan is subject to an export License by the government of Japan. Other models in this manual may
also be subject to export controls. Further, re-export to another country may be subject to the license of the government
of the country from where the product is re-exported. Furthermore, the product may also be controlled by re-export
regulations of the United States government. Should you wish to export or re-export these products, please contact
FANUC for advice.
The products in this manual are manufactured under strict quality control. However, when a serious accident or loss is
predicted due to a failure of the product, pay careful attention to safety.
In this manual, we endeavor to include all pertinent matters.
There are, however, a very large number of operations that must not or cannot be performed, and if the manual
contained them all, it would be enormous in volume.
It is, therefore, requested to assume that any operations that are not explicitly described as being possible are "not
possible".
This manual contains the program names or device names of other companies, some of which are registered
trademarks of respective owners.
However, these names are not followed by ® or ™ in the main body.
Follow the law and the regulation of your country or local government when disposing of the control unit, the amplifier,
the motor and the peripheral units.
ii
B-64805EN/03
Safety precautions
Safety precautions
This section describes precautions to ensure safety in maintenance of FANUC Series 500i-A, which is described in
this manual.
CNC device maintenance involves various dangers and therefore must be undertaken only by qualified technicians.
• The safety precautions must be observed for the safety of yourself and others.
• Various dangers are involved in installing, wiring, exchanging, and performing daily maintenance on the FANUC
Series 500i-A described in this manual and peripheral equipment. Therefore, only persons thoroughly trained in
safety and maintenance should perform such tasks.
• Some safety precautions described in this manual may not apply to your FANUC Series 500i-A and peripheral
equipment because they have no corresponding function. If this is the case, skip reading those precautions.
• For machine safety precautions, also refer to the manual issued by the machine-tool builder.
• Before checking the operation of the machine, take time to become familiar with the manuals provided by the
machine-tool builder and FANUC.
DEFINITION of WARNING, CAUTION, and NOTE
This manual includes safety precautions for protecting the user and preventing damage to the machine and
workpieces. Precautions are classified into HAZARD, WARNING, and CAUTION. Also, supplementary information is
described as a NOTE.
These notations are used depending on the level of expected impact. Read any Hazard, Warning, Caution, and Note
thoroughly before using the machine.
Used when an imminently hazardous situation that may result in death or serious injury to the user is expected to
occur if he or she fails to observe the approved procedure.
Used when a danger that may result in death or serious injury to the user is expected to occur if he or she fails to
observe the approved procedure.
Used when a danger that may result in minor or moderate injury to the user or equipment damage is expected to
occur if he or she fails to observe the approved procedure.
NOTE
Used to provide a supplementary explanation that is not classified into HAZARD, WARNING, or CAUTION.
WARNINGS and CAUTIONS related to check operation
When checking the operation of the machine with the cover removed
The user's clothing could become caught in the spindle or other components, thus presenting a danger of
injury.
iii
Safety precautions
B-64805EN/03
When checking the operation, stand away from the machine to ensure that your clothing does not become
tangled in the spindle or other components.
When checking the operation, perform idle operation without workpiece.
When a workpiece is mounted in the machine, a malfunction could cause the workpiece to be dropped or
destroy the tool tip, possibly scattering fragments throughout the area. This presents a serious danger of
injury. Therefore, stand in a safe location when checking the operation.
When checking the machine operation with the control cabinet door opened
The control cabinet has a high-voltage section (carrying a
mark). Never touch the high-voltage
section. The high-voltage section presents a severe risk of electric shock.
Before starting any check of the operation, confirm that the cover is mounted on the high-voltage section.
When the high-voltage section itself must be checked, note that touching a terminal presents a severe
danger of electric shock.
Within the control cabinet, internal units present potentially injurious corners and projections.
Be careful when working inside the cabinet.
Before machining a workpiece, test run the machine using the following or other methods to confirm that it works
normally.
Operate the machine without mounting tools or workpieces
Use features such as single block, feedrate override, and machine lock
If the machine is used before confirming that it operates normally, the machine may move unpredictably, possibly
causing injury to the user or damage to the workpiece and/or the machine.
Before operating the machine, thoroughly check that the entered data is correct. Otherwise, unpredictable machine
movement could damage the workpiece or the machine itself or cause injury.
Ensure that the specified feedrate is appropriate for the intended operation. Generally, each machine has the
maximum allowable feedrate. The appropriate feedrate varies with the intended operation. Refer to the manual
provided with the machine-tool builder to determine the maximum allowable feedrate. If a machine is run at an
inappropriate speed, it may behave unexpectedly, possibly causing injury to the user or damage to the workpiece
and/or machine itself.
When using a tool compensation function, check the direction and amount of compensation. Otherwise,
unpredictable machine movement could damage the workpiece or the machine itself or cause injury.
Laser safety precautions
Some of the FSSB optical modules included in this product are Class 1 laser products and conform to 21 CFR,
Subchapter J of the FDA of the USA and to the international standard IEC60825-1.
Class 1 lasers are safe for observation by the naked eye or using a telephotographic optical system such as glasses;
however, avoid directly viewing the laser if possible.
In particular, the laser used in this product is near infrared light with a wavelength of 850 nm which is difficult to check
visually, so if observation is necessary, use a near-infrared camera or the like rather than a loupe or the like.
Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.
WARNINGS and CAUTIONS related to replacement
Before replacing a unit, be sure to shut off externally supplied power. Otherwise, electrical shocks, breakdown, and
blowout may occur.
If a control unit is turned off but other units are not, it is likely that power may be supplied to servo units, resulting
in the units being damaged and workers getting an electrical shock when the units are exchanged.
In order to prevent damage that may be caused by static electricity, wear a grounding wrist strap or take a similar
appropriate protective measure before touching a printed circuit board or unit or connecting a cable.
Static electricity from human bodies can damage electrical circuits.
Voltage lingers in servo and spindle amplifiers for a while even after power has been turned off, resulting in
workers who touch them possibly getting an electrical shock. Before starting to exchange these amplifiers, wait for
20 minutes after power has been turned off.
When replacing a unit, specify the same settings and parameters in the newly installed unit as those for the one
removed. (For details, refer to the respective manuals for the units.)
iv
B-64805EN/03
Safety precautions
Operating the newly installed unit with incorrect settings or parameters will cause the machine to behave
unexpectedly, possibly leading to a damaged workpiece or machine or injury.
If you notice an apparent hardware fault, such as abnormal noise, abnormal odor, smoke, ignition, or abnormal
heat, in the hardware while power is being supplied to it, shut it off at once. These faults can cause fire,
breakdown, blowout, and malfunction.
The radiating fins of control units, servo amplifiers, spindle amplifiers, and other devices can remain very hot for a
while after power has been turned off, making you get burned if you touch them. Before starting to work on them,
wait and make sure they are cool.
When replacing something heavy, two or more workers should replace it together.
If a worker attempts the replacement alone, they might drop a replacement unit and get injured.
Be careful not to damage cables. Otherwise, electrical shocks can occur.
When working, wear suitable clothes with safety taken into account. Otherwise, injury and electrical shocks can
occur.
Do not work with your hands wet. Otherwise, electrical shocks and damage to electrical circuits can occur.
WARNINGS and CAUTIONS related to parameters
When machining a workpiece for the first time after modifying a parameter, close the machine cover.
Never use the automatic operation function immediately after such a modification. Instead, confirm that the
machine operates normally by using functions such as the single block function, feedrate override function, and
machine lock function, or by operating the machine without mounting a tool and workpiece. If the machine is used
before confirming that it operates normally, the machine may move unpredictably, possibly causing injury to the
user or damage to the workpiece and/or the machine.
The control unit and PMC parameters are preset to their optimal values, so those parameters usually need not be
modified.
When any of those parameters must be modified for some reason, ensure that you fully understand the function of
that parameter before attempting to modify it. If the parameters are set incorrectly, the machine may move
unpredictably, possibly causing injury to the user or damage to the workpiece and/or the machine.
WARNINGS, CAUTIONS, and NOTES related to daily maintenance
Chips and coolant
When using the control unit, LCD unit, MDI unit, or machine operator's panel, prevent these units from directly
exposing to chips or coolant.
Coolants containing sulfur or chlorine, oil-free coolants called "synthetic", and water-soluble coolants with a high
alkalinity, in particular, can greatly affect the control units and peripheral units. Please be very careful, as exposing
them to these coolants may cause the following trouble.
Coolants containing sulfur or chlorine
Some coolants containing sulfur or chlorine are at an extremely high activity level. If such a coolant adheres
to the CNC or peripheral units, it reacts chemically with a material, such as resin, of equipment, possibly
leading to corrosion or deterioration. If it gets in the CNC or peripheral units, it corrodes metals, such as
copper and silver, used as component materials, possibly leading to a defective component.
Oil-free, "synthetic" coolants
Some synthetic-type coolants whose lubricating component is, for example, PAG (polyalkylene glycol) have
an extremely high permeability. If such a coolant is used even in equipment having a high closeness, it can
readily flow into the CNC or peripheral units through, for example, gaskets. It is likely that, if the coolant gets
in the Control units or a peripheral unit, it may deteriorate the insulation and damage the components.
Water-soluble coolants with a high alkalinity
Some coolants whose pH is increased using alkanolamine or the like are so strongly alkaline that their
standard dilution will still result in pH10 or higher. If such a coolant adheres to the surface of the CNC or
peripheral units, it reacts chemically with a material, such as resin, possibly leading to corrosion or
deterioration.
Battery replacement
Battery replacement work must be done only by a person who is trained in the related maintenance and safety
requirements.
v
Safety precautions
B-64805EN/03
When opening the cabinet to replace a battery, be careful not to touch any high-voltage circuit (marked with
and covered with an electric shock prevention cover). If the electric shock prevention cover has been removed, do
not touch the inside to prevent electric shock.
Fuse replacement
Fuse replacement work must be done only by a person who is trained in the related maintenance and safety
requirements.
Before replacing a fuse, the cause of the blown fuse must be corrected.
When opening the cabinet to replace a fuse, be careful not to touch any high-voltage circuit (marked with
and
covered with an electric shock prevention cover). If the electric shock prevention cover has been removed, do not
touch the inside to prevent electric shock.
Handle the batteries gently. Do not drop them or give a strong impact to them.
NOTE
The control unit uses batteries in order to retain clock information even when the power is turned off.
If the battery voltage becomes low, a low battery voltage alarm is displayed on the display device.
When you notice the alarm, replace the battery as soon as possible. Otherwise, clock information may be lost. It should
be replaced within two weeks, but this depends on the system configuration.
For the battery replacement procedure, see "V.1.5. Replace Battery for Clock Function in Control Unit(P.731)". Recollect or
discard old batteries in the way your local autonomous community specifies.
Data such as programs, offset amounts, and parameters will not be lost with a drop in battery voltage, but it is
recommended that backups be made in case of unexpected malfunctions.
Note regarding Korean KC mark
NOTE
This product is a Class A electromagnetic compatibility device for professional use, and the seller and user should
take this into consideration when using it outside homes.
vi
B-64805EN/03
Preface
Preface
This manual provides information required for maintenance of the control unit, peripheral units, and machine tools
listed below, including their electrical and structural specifications. The scope covered by this manual is that shown in
"CONTROL UNIT AND DISPLAY LCD UNIT HARDWARE". The manual provides a brief summary of the units that
are used in common with the FANUC control units, such as FANUC I/O units, FANUC iPC, and servo motors. It also
gives supplementary information for use of these units with the control units. For detailed specifications, refer to the
manuals of these components.
For options not covered in this manual, also refer to the manuals of these components.
NOTE
The copyright of WindowsⓇ 10 IoT Enterprise 2021 LTSC and accompanying software used with FANUC iPC
graphic board belongs to Microsoft Corporation (USA), Intel Corporation, American Megatrends (AMI), and
FANUC Corporation.
No part of the software and its manuals described above shall be used or reproduced without permission.
No part of the software and its manuals described above shall be sold separately from the FANUC iPC graphic
board.
The software and its manuals described above must be used under the conditions described in the attached
license agreement.
The user of FANUC iPC graphic board shall be deemed to have consented to the license agreement above upon
power-on of CNC that include FANUC iPC graphic board.
Trademarks of other companies used in thin manual
"Microsoft" and "Windows" are the registered trademarks or trademarks of Microsoft Corporation.
The "SDHC" logo is the trademark of "SD-3C LLC".
Other company names and product names stated in this manual are the registered trademarks or trademarks of their
respective companies.
In the text, figures, and tables in this manual, "™" and "®" are omitted.
Data stored in SSD may corrupt by incorrect operation, an unexpected accident, or a virus attack. Be sure to make
periodic backups for important data in SSD for restoring. Never turn off the power of SSD while accessing them
since power cut-off during an access to SSD increases the possibility of data corruption or loss. The machine-tool
builder should advise its users to exercise appropriate cautions for data corruption or loss.
Shut down the OS and applications according to the authorized shutdown procedure before turning off the power.
If turning off the power without terminating the application and OS, the subsequent behaviors will not be
guaranteed. In the worst case, SSD may be damaged and not recognized by BIOS and OS.
Description of this manual
This manual includes the following parts:
I. Equipment overview
Chapter 1: Control unit and LCD unit hardware
This chapter describes the hardware configuration, printed circuit boards and their mounting positions, and LED
indications and mounting positions of the control unit.
Chapter 2: LCD unit interfaces
This chapter describes SD card and USB connections.
vii
Preface
B-64805EN/03
II. Display and operation of screens
This chapter covers maintenance-related items displayed on the screen. A list of all supported operations is also
provided at the end of this chapter.
III. Interface configuration
Chapter 1: Interface between CNC and PMC
This chapter describes the specifications, the system configuration, and the signal list of the PMC.
Chapter 2: Embedded ethernet function
This chapter describes the embedded Ethernet.
IV. Fault handling
Chapter 1: Troubleshooting
This chapter describes the procedures to be followed when an alarm occurs.
Chapter 2: Alarm list
A list of alarms is provided.
Chapter 3: Diagnosis list
This section describes the diagnostic results when an alarm occurs.
Chapter 4: Trouble diagnosis
This section describes the investigation procedures and trouble diagnosis screens to use when an alarm occurs.
V. Parts change
Chapter 1: Replacing control unit maintenance parts
This chapter describes the replacement of maintenance parts of the control unit.
Chapter 2: Maintenance of the other unit
This chapter describes the basics of maintenance of other units.
VI. Adjustment
Chapter 1: Digital servo
This chapter describes the servo setting screen and how to adjust the reference position return position.
Chapter 2: AC Spindle
This chapter describes the spindle setting screen.
Chapter 3: Setting and adjusting the servo spindle
This chapter describes servo and spindle settings and tuning.
VII. Setting data
Chapter 1: Inputting/Outputting data
This chapter describes the input/output of data, including programs, parameters, tool compensation amount,and
conversational data input/output procedures.
Chapter 2: Maintenance operations for the stand-alone type control unit
This chapter describes maintenance operations in the absence of a display unit.
Chapter 3: CNC maintenance operation (BOOT)
This chapter describes the boot system.
viii
B-64805EN/03
Preface
Chapter 4: FANUC iPC graphic board (FIP1110) maintenance operation (hardware monitor)
This chapter describes hardware monitors that work with FANUC iPC graphic board (FIP1110).
Appendix
A. Lists of units, printed circuit boards, and consumables
Describes the parts list for ordering various units, printed circuit boards, and consumables.
B. BIOS setup
Describes how to set BIOS values (BIOS Setup).
C. USB-Ethernet conversion unit
Describes the USB-Ethernet conversion unit used for maintenance.
This manual does not provide a parameter list.
See the parameter list in "Series 500i-A PARAMETER MANUAL" (B-64810EN).
Applicable models
This manual is for the following models.
In addition, the following model names are abbreviated in some places.
Table 3.4-1 List of abbreviations
Series name
Model name
FANUC Series 500i-A
FANUC Series 501iS-A
FANUC Series 501i-A
FANUC Series 502iS-A
FANUC Series 502i-A
FANUC Series 503i-A
Abbreviation
501iS-A
501i-A
502iS-A
502i-A
503i-A
Series 501i
Series
500i-A
Series 500i
500i
Series 502i
Series 503i
NOTE
1. For an explanatory purpose, the following descriptions may be used according to the types of path control used:
M series: For the machining center system
T series: For the lathe system
2. In this manual, the series name (FANUC Series 500i-A) or its abbreviation is used unless otherwise specified.
However, if there are functions that are not available for some models, the model names are provided.
3. Some functions described in this manual may not be applied to some products. Refer to DESCRIPTIONS.
Related manuals of FANUC Series 500i-A
The manuals related to FANUC Series 500i-A are as listed in Table 3.5-1.
Table 3.5-1 Related manuals
Type
Fundamental
"Manual name" (Specification number)
This manual
"Series 500i-A DESCRIPTIONS" (B-64802EN)
"Series 500i-A CONNECTION MANUAL (HARDWARE)" (B-64803EN)
"Series 500i-A CONNECTION MANUAL (FUNCTION)" (B-64803EN-1)
"Series 500i-A OPERATOR'S MANUAL" (B-64804EN)
"Series 500i-A MAINTENANCE MANUAL" (B-64805EN)
〇
"Series 500i-A PARAMETER MANUAL" (B-64810EN)
ix
Preface
Type
Programming
Network
Dual check safety
B-64805EN/03
"Manual name" (Specification number)
This manual
"Series 500i-A CNC PROGRAMMING MANUAL" (B-64804EN-1)
"Series 500i-A PMC PROGRAMMING MANUAL" (B-64803EN-3)
"Series 500i-A Macro Compiler / Macro Executor PROGRAMMING
MANUAL" (B-64803EN-5)
"Series 500i-A Industrial Ethernet CONNECTION MANUAL" (B64803EN-6)
"Series 500i-A Fieldbus (PROFIBUS) CONNECTION MANUAL" (B64803EN-7)
"Series 500i-A Dual Check Safety CONNECTION MANUAL" (B64803EN-2)
Related manuals of Servo Motor
Manuals related to the servo motor are listed in Table 3.6-1 below.
Table 3.6-1 Related manuals
"Manual name" (Specification number)
"SERVO MOTOR αi-D series DESCRIPTIONS" (B-65542EN)
"SPINDLE MOTOR αi-D series DESCRIPTIONS" (B-65532EN)
"SERVO AMPLIFIER αi-D series DESCRIPTIONS" (B-65552EN)
"SERVO MOTOR αi-D series, SPINDLE MOTOR αi-D series, SERVO AMPLIFIER αi-D series MAINTENANCE
MANUAL" (B-65555EN)
"DD MOTOR DiS series Descriptions" (B-65332EN)
"DD MOTOR DiS-B series DESCRIPTIONS" (B-65492EN)
"LINEAR MOTOR LiS series DESCRIPTIONS" (B-65382EN)
"LINEAR MOTOR LiS-B series DESCRIPTIONS" (B-65482EN)
"BUILT-IN SPINDLE MOTOR BiI-B series DESCRIPTIONS" (B-65462EN)
"SYNCHROUNOUS BUILT-IN SPINDLE MOTOR BiS series DESCRIPTIONS"(B-65342EN)
"AC SERVO MOTOR αi-B/αi series, AC SERVO MOTOR βi-B/βi series, LINEAR MOTOR LiS-B/LiS series, DD
MOTOR DiS-B/DiS series PARAMETER MANUAL" (B-65270EN)
"SPINDLE MOTOR αi-D/αi-B/αi series, AC SPINDLE MOTOR βi-B/βi series, BUILT-IN SPINDLE MOTOR Bi-B/Bi
series SPINDLE PARAMETER MANUAL" (B-65280EN)
Related manuals of FANUC iPC
Manuals related to FANUC iPC are listed in Table 3.7-1 below.
Table 3.7-1 Related manuals
"Manual name" (Specification number)
"FANUC iPC FIP1000 Series CONNECTION AND MAINTENANCE MANUAL" (B-64763EN)
"FANUC iPC FIP1100 Series CONNECTION AND MAINTENANCE MANUAL"(B-64933EN)
Related manuals of FANUC I/O unit
Manuals related to FANUC I/O unit motor are listed in Table 3.8-1 below.
Table 3.8-1 Related manuals
"Manual name" (Specification number)
"I/O Unit-MODEL A CONNECTION AND MAINTENANCE MANUAL” (B-61813E)
"I/O Unit-MODEL B CONNECTION MANUAL” (B-62163E)
"FANUC I/O unit CONNECTION MANUAL" (B-64793EN)
x
B-64805EN/03
Preface
"Manual name" (Specification number)
"FANUC I/O unit MAINTENANCE MANUAL" (B-64795EN)
Training
FANUC runs Fanuc Academy to train those who will be involved in the connection, maintenance, and operation of
FANUC products.
Fanuc Academy offers various training courses from which you can gain knowledge and practical experience related
to CNC and robots. We recommend that you attend the courses so that you will be able to use the products
effectively and efficiently.
Visit the following web site for detailed descriptions of the curriculum:
http://www.fanuc.co.jp/
xi
Table of contents
B-64805EN/03
Table of contents
Important information ...................................................................................................... ii
Safety precautions .......................................................................................................... iii
DEFINITION of WARNING, CAUTION, and NOTE .............................................................................................. iii
WARNINGS and CAUTIONS related to check operation ..................................................................................... iii
Laser safety precautions ......................................................................................................................................iv
WARNINGS and CAUTIONS related to replacement ...........................................................................................iv
WARNINGS and CAUTIONS related to parameters ............................................................................................ v
WARNINGS, CAUTIONS, and NOTES related to daily maintenance .................................................................. v
Note regarding Korean KC mark ..........................................................................................................................vi
Preface ............................................................................................................................ vii
Trademarks of other companies used in thin manual .......................................................................................... vii
Description of this manual ................................................................................................................................... vii
Appendix ..............................................................................................................................................................ix
Applicable models ................................................................................................................................................ix
Related manuals of FANUC Series 500i-A ...........................................................................................................ix
Related manuals of Servo Motor .......................................................................................................................... x
Related manuals of FANUC iPC .......................................................................................................................... x
Related manuals of FANUC I/O unit ..................................................................................................................... x
Training ................................................................................................................................................................xi
I Equipment overview ...................................................................................................... 1
1.
Control unit and lcd unit hardware ............................................................................................................. 3
1.1.
System configuration examples .................................................................................................. 3
1.2.
1.1.1.
Control unit and LCD unit configuration..................................................................................... 3
1.1.2.
System Configuration Example of LCD-mounted Type Control Unit .......................................... 5
1.1.3.
System Configuration Example of Stand-alone Type Control Unit ............................................. 6
Control Unit Hardware ................................................................................................................. 7
1.2.1.
Main board ............................................................................................................................... 9
1.2.2.
CPU board.............................................................................................................................. 13
1.2.3.
Memory board ........................................................................................................................ 15
1.2.4.
Power supply board ................................................................................................................ 17
1.2.5.
Graphic board ......................................................................................................................... 19
1.2.6.
1.2.5.1.
FANUC iPC graphic board (FIP 1110) ............................................................... 19
1.2.5.2.
Interface board A ............................................................................................... 22
Expansion board ..................................................................................................................... 28
1.2.6.1.
1.2.7.
1.3.
1.4.
1.5.
1.6.
xii
Ethernet expansion board B .............................................................................. 28
Optional board ........................................................................................................................ 31
1.2.7.1.
Storage Expansion Board .................................................................................. 31
1.2.7.2.
PROFIBUS-DP board ........................................................................................ 32
1.2.8.
Fan Units and Fans ................................................................................................................ 35
1.2.9.
Lithium battery ........................................................................................................................ 37
LCD unit hardware .................................................................................................................... 39
1.3.1.
LCD unit ................................................................................................................................. 40
1.3.2.
LED Mounting Positions and LED Indications on LCD Unit ..................................................... 40
1.3.3.
LCD unit precautions .............................................................................................................. 42
Overall connection diagram....................................................................................................... 42
Installation environment ............................................................................................................ 44
1.5.1.
Environmental Conditions for Cabinet Installation ................................................................... 45
1.5.2.
Installation conditions of the control unit.................................................................................. 45
Cautions related to grounding and noise ................................................................................... 46
1.6.1.
Separating Cables .................................................................................................................. 46
1.6.2.
Surge Absorber ...................................................................................................................... 48
B-64805EN/03
2.
Table of contents
1.6.3.
Cable Clamp and Shield Processing ....................................................................................... 50
1.6.4.
Lightning Surge Absorber Installation ..................................................................................... 54
LCD unit interfaces .................................................................................................................................. 55
2.1.
SD Card .................................................................................................................................... 55
2.2.
USB ........................................................................................................................................... 56
II Display and operation of screens .............................................................................. 59
1.
2.
3.
Menu Screen, Function Keys, and Soft Keys........................................................................................... 61
1.1.
General Screen Operations....................................................................................................... 61
1.2.
Menu Screen ............................................................................................................................. 61
1.3.
Function Keys ........................................................................................................................... 63
1.4.
Soft keys ................................................................................................................................... 63
System configuration screen .................................................................................................................... 65
2.1.
Displaying System Configuration Screen .................................................................................. 65
2.2.
Names and functions of each section of the System Configuration Screen .............................. 67
5.
6.
7.
8.
Soft Keys on the System Configuration Screen....................................................................... 67
2.2.2.
Information Displayed on the System Configuration Screen .................................................... 70
2.3.
Changing Servo and Spindle ID Information ............................................................................. 70
Diagnosis screen ..................................................................................................................................... 72
3.1.
Displaying the Diagnosis Screen ............................................................................................... 72
3.2.
Names and Functions of Each Section of the Diagnosis Screen .............................................. 74
3.3.
4.
2.2.1.
3.2.1.
Soft Keys on the Diagnosis Screen ......................................................................................... 74
3.2.2.
Information Displayed on the Diagnosis Screen ...................................................................... 76
Searching for Diagnosis Data.................................................................................................... 78
3.3.1.
Displaying the Search Window ............................................................................................... 78
3.3.2.
Names and Functions of Each Section of the Search Window ................................................ 80
3.3.3.
Searching by Diagnosis Number ............................................................................................. 81
CNC state display .................................................................................................................................... 82
4.1.
Items Displayed in the Status Display Section .......................................................................... 82
4.1.1.
Viewing CNC Status ............................................................................................................... 82
4.1.2.
Viewing Messages .................................................................................................................. 84
4.1.3.
Viewing User Information ........................................................................................................ 85
4.1.4.
Viewing the Time .................................................................................................................... 85
Maintenance information screen .............................................................................................................. 86
5.1.
Displaying the Maintenance Information Screen ....................................................................... 86
5.2.
Names and Functions of Each Section of the Maintenance Information Screen ....................... 88
5.2.1.
Soft Keys on the Maintenance Information Screen.................................................................. 88
5.2.2.
Information Displayed on the Maintenance Information Screen ............................................... 90
5.3.
Parameters................................................................................................................................ 92
FSSB connection status screen ............................................................................................................... 94
6.1.
Displaying the FSSB connection status Screen ........................................................................ 94
6.2.
Names and Functions of Each Section of the FSSB connection status Screen ........................ 96
6.2.1.
Soft Keys on the FSSB connection status screen ................................................................... 96
6.2.2.
Information Displayed on the FSSB connection status screen ................................................ 98
Maintenance Monitor Screen ................................................................................................................. 103
7.1.
Displaying the Maintenance Monitor Screen ........................................................................... 103
7.2.
Names and Functions of Each Section of the Maintenance Monitor Screen ........................... 105
7.2.1.
Soft Keys on the Maintenance Monitor Screen ..................................................................... 106
7.2.2.
Information Displayed on the Maintenance Monitor Screen .................................................. 107
History screen ........................................................................................................................................ 115
8.1.
Message History ..................................................................................................................... 115
8.2.
8.1.1.
Displaying the Message History screen ................................................................................ 115
8.1.2.
Names and functions of each part of the Message History screen ........................................ 115
8.1.3.
Operating the Message History screen ................................................................................. 117
Operation history ..................................................................................................................... 117
xiii
Table of contents
8.3.
B-64805EN/03
8.2.1.
Displaying the Operation History screen ............................................................................... 117
8.2.2.
Names and functions of each section of the Operation History Screen ................................. 117
8.2.3.
Operating the Operation History screen ................................................................................ 122
System alarm history ............................................................................................................... 122
8.3.1.
Displaying the System Alarm History screen ......................................................................... 122
8.3.2.
Names and functions of each section of the System Alarm History screen............................ 123
III Interface configuration ............................................................................................ 125
1.
Interface between CNC and PMC .......................................................................................................... 127
1.1.
What is PMC? ......................................................................................................................... 127
1.1.1.
Basic Configuration of PMC .................................................................................................. 127
1.1.2.
PMC Program Memory ......................................................................................................... 128
1.1.3.
PMC data memory ................................................................................................................ 130
1.1.4.
1.1.5.
1.2.
1.3.
2.
1.1.3.1.
PMC Address .................................................................................................. 131
1.1.3.2.
Retained Data Memory .................................................................................... 133
FANUC I/O LINK i CONNECTIONS ...................................................................................... 133
1.1.4.1.
FANUC I/O LINK i Specifications ..................................................................... 134
1.1.4.2.
FANUC I/O Link i allocation ............................................................................. 135
Basic Specifications of the PMC ........................................................................................... 136
Operating the PMC screen ...................................................................................................... 139
Input/output signal address table ............................................................................................ 140
1.3.1.
Signals from the Machine Tool to CNC ................................................................................. 143
1.3.2.
Signals from PMC to CNC .................................................................................................... 145
1.3.3.
Signals from CNC to PMC .................................................................................................... 175
Embedded ethernet function .................................................................................................................. 206
2.1.
Network settings screen .......................................................................................................... 208
2.2.
Network Log screen ................................................................................................................ 251
2.3.
Industrial Network Screen ....................................................................................................... 255
IV Fault handling .......................................................................................................... 261
1.
Troubleshooting ..................................................................................................................................... 263
1.1.
Corrective action for failures.................................................................................................... 263
1.1.1.
1.2.
1.3.
1.4.
1.5.
1.6.
1.7.
1.8.
1.9.
1.10.
1.11.
1.12.
1.13.
1.14.
1.15.
1.16.
1.17.
1.18.
1.19.
1.20.
1.21.
xiv
Investigating the Conditions under which Failure Occurred ................................................... 263
No manual operation nor automatic operation can be executed ............................................. 265
Jog operation cannot be done ................................................................................................. 270
HANDLE OPERATION CANNOT BE DONE .......................................................................... 275
Automatic operation cannot be done ....................................................................................... 284
Cycle start led signal has turned off ........................................................................................ 291
Nothing is displayed on the LCD, or the display disappears and is not restored ..................... 292
The displayed content is distorted or does not fit within the screen ........................................ 294
Input from and output to i/o devices cannot be performed, input/output cannot be performed
properly ................................................................................................................................... 294
ALARM SR0085 TO 87 (RELATED TO RS-232C INTERFACE) ............................................ 297
ALARM PS0090 (REFERENCE POSITION RETURN IS ABNORMAL) ................................. 301
ALARM DS0300 (REQUEST FOR REFERENCE POSITION RETURN) ................................ 303
ALARM SV0401 (V READY OFF) ........................................................................................... 304
ALARM SV0404 (V READY ON) ............................................................................................. 306
ALARM SV0462 (SEND CNC DATA FAILED), ALARM SV0463 (SEND SLAVE DATA FAILED)
................................................................................................................................................ 306
ALARM SV0417 (DIGITAL SERVO SYSTEM IS ABNORMAL) .............................................. 306
ALARMS OH10000 TO OH10003 (OVERHEAT) .................................................................... 307
ALARM SV5134 (FSSB: OPEN READY TIME OUT) ALARM SV5137 (FSSB:
CONFIGURATION ERROR) ALARM SV5197 (FSSB: OPEN TIME OUT) ............................. 307
Alarm SV1067 (Diagnosis No. 3511=481) (FSSB: Configuration Error (Software)) ................ 308
Servo alarms ........................................................................................................................... 308
Spindle alarms ........................................................................................................................ 308
B-64805EN/03
1.22.
2.
3.
4.
Table of contents
System alarms ........................................................................................................................ 309
1.22.1.
Overview .............................................................................................................................. 309
1.22.2.
System Alarm Screen ........................................................................................................... 309
1.23.
LEDs ON UNITS SUPPORTING I/O LINK I ............................................................................ 310
Alarm list ................................................................................................................................................ 311
2.1.
Alarm list (CNC and PMC) ...................................................................................................... 311
2.1.1.
Program Operation Alarms (PS Alarm) ................................................................................. 311
2.1.2.
Background Edit Alarms (BG Alarm) ..................................................................................... 382
2.1.3.
Communication Alarms (SR Alarm) ...................................................................................... 387
2.1.4.
Parameter Writing Alarm (SW Alarm) ................................................................................... 393
2.1.5.
Servo Alarms (SV Alarm) ...................................................................................................... 393
2.1.6.
Overtravel Alarms (OT Alarm)............................................................................................... 412
2.1.7.
Memory File Alarms (IO Alarm) ............................................................................................. 414
2.1.8.
Alarms Requiring Power To Be Turned Off (PW Alarm) ........................................................ 415
2.1.9.
Spindle Alarms (SP Alarm) ................................................................................................... 423
2.1.10.
Overheat Alarms (OH Alarm) ................................................................................................ 430
2.1.11.
Other Alarms (DS Alarm) ...................................................................................................... 430
2.1.12.
Malfunction Prevention Function Alarms (IE Alarm) .............................................................. 452
2.1.13.
PMC Alarms (PMC Alarm) .................................................................................................... 452
2.1.14.
I/O Link i Alarms (IOL Alarm) ................................................................................................ 457
2.1.15.
Warning Alarms (WNG Alarm) .............................................................................................. 461
2.2.
Alarm List (Spindle) ................................................................................................................. 465
2.3.
Error code list (spindle) ........................................................................................................... 478
2.4.
System alarm .......................................................................................................................... 482
Diagnosis list.......................................................................................................................................... 534
3.1.
Diagnosis list ........................................................................................................................... 534
Trouble diagnosis .................................................................................................................................. 644
4.1.
Overview ................................................................................................................................. 644
4.2.
Investigation procedure of cause of alarm occurrence ............................................................ 644
4.2.1.
4.2.2.
4.3.
4.4.
Checking CNC Status ........................................................................................................... 644
4.2.1.1.
Displaying the Message Screen ...................................................................... 644
4.2.1.2.
Items Displayed in the Message Screen .......................................................... 644
4.2.1.3.
Operating with MDI keys .................................................................................. 645
4.2.1.4.
Operating with horizontal soft keys .................................................................. 646
Investigating the Cause of an Alarm or Operator Message ................................................... 647
4.2.2.1.
Items Displayed in the Troubleshooting Window .............................................. 647
4.2.2.2.
Performing Troubleshooting............................................................................. 649
Parameters.............................................................................................................................. 651
Trouble Diagnosis Monitor screen ........................................................................................... 651
V Parts change ............................................................................................................. 665
1.
Replacing control unit maintenance parts .............................................................................................. 667
1.1.
Cautions for replacement ........................................................................................................ 667
1.2.
1.1.1.
Optional information file ........................................................................................................ 668
1.1.2.
Packing................................................................................................................................. 668
Replacement of various units .................................................................................................. 669
1.2.1.
Replacing the LCD-mounted type control unit ....................................................................... 669
1.2.2.
Replacing the stand-alone type control unit .......................................................................... 675
1.2.3.
Replacing LCD units ............................................................................................................. 680
1.2.3.1.
Replacing the 10.4-inch LCD unit .................................................................... 680
1.2.3.2.
Replacing the 15-inch LCD unit ....................................................................... 682
1.2.3.3.
Replacing the 18.5-inch LCD unit .................................................................... 685
1.2.3.4.
Replacing the 21.5-inch LCD unit .................................................................... 691
1.2.3.5.
Replacing the 24-inch LCD unit ....................................................................... 698
1.2.4.
Inserting and Removing Cables ............................................................................................ 705
1.2.5.
Replacement of the cover for SD card slot / USB port on the LCD unit ................................. 709
xv
Table of contents
1.3.
1.4.
1.5.
1.6.
B-64805EN/03
Ordering specification for replacement parts .................................................... 710
1.2.5.2.
10.4-inch or 15-inch LCD unit .......................................................................... 711
1.2.5.3.
18.5-inch, 21.5-inch, or 24-inch LCD unit ......................................................... 713
Replacement of various printed circuit board .......................................................................... 718
1.3.1.
Replacing the main board ..................................................................................................... 719
1.3.2.
Replacement of non-main board ........................................................................................... 723
Replacement of fan unit and fan ............................................................................................. 725
1.4.1.
Removal and installation of fan unit ...................................................................................... 726
1.4.2.
Fan replacement ................................................................................................................... 729
Replace Battery for Clock Function in Control Unit ................................................................. 731
1.5.1.
Replacing a Lithium Battery .................................................................................................. 733
1.5.2.
How to replace the battery in a battery case ......................................................................... 735
Fuse replacement ................................................................................................................... 736
1.6.1.
2.
1.2.5.1.
Replace fuses on power board ............................................................................................. 736
1.7.
M.2 SSD replacement ............................................................................................................. 739
Maintenance of the other units ............................................................................................................... 741
2.1.
Cautions common to the other units ........................................................................................ 741
2.2.
2.3.
2.4.
2.5.
2.1.1.
Cautions for replacement ...................................................................................................... 741
2.1.2.
Tightening torque for fastening units and ground terminals ................................................... 741
MDI unit ................................................................................................................................... 742
2.2.1.
Overview .............................................................................................................................. 742
2.2.2.
MDI unit specification ............................................................................................................ 743
2.2.3.
Grounding when using the MDI unit ...................................................................................... 744
2.2.4.
MDI unit replacement............................................................................................................ 745
2.2.5.
Connection between the LCD-mounted type control unit and the MDI unit ............................ 747
2.2.6.
MDI unit key input ................................................................................................................. 748
2.2.7.
Replacing the Keyboard Cover ............................................................................................. 749
Separate detector interface unit .............................................................................................. 751
2.3.1.
Separate detector interface unit specifications ...................................................................... 751
2.3.2.
LED mounting positions ........................................................................................................ 751
2.3.3.
Connector locations .............................................................................................................. 752
2.3.4.
Connection Between the Basic Unit and Additional Unit........................................................ 755
2.3.5.
Installing the separate detector interface unit (cabinet) ......................................................... 756
2.3.6.
Installing the separate detector interface unit (DIN rail) ......................................................... 757
2.3.7.
Ground wire connection ........................................................................................................ 760
Replacing battery for absolute pulsecoders ............................................................................ 760
2.4.1.
Overview .............................................................................................................................. 760
2.4.2.
Replacing Batteries............................................................................................................... 761
2.4.3.
Replacing the Batteries in a Separate Battery Case.............................................................. 761
Units that support I/O Link i ..................................................................................................... 762
VI Adjustment ............................................................................................................... 763
1.
2.
3.
xvi
Digital servo ........................................................................................................................................... 765
1.1.
FSSB setting screen ............................................................................................................... 765
1.2.
Adjusting reference position return position (DOG method) .................................................... 782
1.3.
Reference position setting without DOG ................................................................................. 784
1.4.
αi Servo Warning Interface ...................................................................................................... 786
AC Spindle ............................................................................................................................................. 789
2.1.
Serial interface ac spindle ....................................................................................................... 789
2.1.1.
Outline of Spindle Control ..................................................................................................... 789
2.1.2.
Automatic Setting of Standard Parameters ........................................................................... 790
2.1.3.
Warning Interface ................................................................................................................. 792
Setting and adjusting the servo spindle ................................................................................................. 794
3.1.
SVSP settings screen.............................................................................................................. 794
3.1.1.
SVSP settings screen ........................................................................................................... 794
3.1.2.
Names and functions of each part of the SVSP settings screen ............................................ 795
B-64805EN/03
3.2.
3.3.
Table of contents
3.1.3.
Set servo parameters ........................................................................................................... 796
3.1.4.
Set spindle parameters ......................................................................................................... 799
SVSP tunings screen .............................................................................................................. 801
3.2.1.
Displaying the SVSP tunings screen ..................................................................................... 801
3.2.2.
Names and functions of each part of the SVSP tunings screen ............................................. 804
3.2.3.
Adjust servo parameters ....................................................................................................... 804
3.2.4.
Adjusting spindle parameters ................................................................................................ 806
Spindle monitor screen............................................................................................................ 810
3.3.1.
Display spindle monitor screen ............................................................................................. 810
3.3.2.
Names and functions of each part of the spindle monitor screen........................................... 813
3.3.3.
Monitor spindle monitor......................................................................................................... 813
VII Setting data ............................................................................................................. 819
1.
2.
3.
Inputting/Outputting data........................................................................................................................ 821
1.1.
Set parameters required for input ............................................................................................ 821
1.2.
Input/output data (data input/output screen)............................................................................ 822
1.2.1.
Input/output CNC data .......................................................................................................... 822
1.2.2.
Input/output CNC programs .................................................................................................. 824
1.2.3.
Input/output PMC data .......................................................................................................... 825
1.2.4.
Input/output Graphic data ..................................................................................................... 826
1.3.
Automatic data backup ............................................................................................................ 827
1.4.
Formatting SD card / USB memory ......................................................................................... 833
Maintenance operations for the stand-alone type control unit................................................................ 836
2.1.
Overview ................................................................................................................................. 836
2.2.
Operation method ................................................................................................................... 836
2.3.
OPERATION OF EACH FUNCTION ....................................................................................... 836
CNC maintenance operation (BOOT) .................................................................................................... 840
3.1.
Changing CNC start sequence ................................................................................................ 841
3.2.
Explanation of screens ............................................................................................................ 843
3.2.1.
About screen ........................................................................................................................ 843
3.2.2.
Status screen........................................................................................................................ 843
3.2.3.
Graphic soft load screen ....................................................................................................... 844
3.2.4.
App Starter screen ................................................................................................................ 844
3.2.5.
IP Setting screen .................................................................................................................. 845
3.2.6.
Boot Screen .......................................................................................................................... 846
3.2.6.1.
3.2.7.
4.
List of data cleared by NVRAM all-clear........................................................... 853
SYSTEM ALARM screen ...................................................................................................... 854
FANUC iPC graphic board (FIP1110) maintenance operations (hardware monitor) .............................. 857
4.1.
Overview ................................................................................................................................. 857
4.2.
Description for each window ................................................................................................... 857
4.3.
4.2.1.
Monitor window..................................................................................................................... 858
4.2.2.
Various settings window ....................................................................................................... 859
4.2.3.
UWF control window (for Windows 10 IoT Enterprise) .......................................................... 861
4.2.4.
System window..................................................................................................................... 862
4.2.5.
Version information window .................................................................................................. 864
4.2.6.
Notification Screen................................................................................................................ 865
Log output function .................................................................................................................. 865
Appendix....................................................................................................................... 867
A.
Lists of units, printed circuit boards, and consumables .......................................................................... 869
A.1.
Control unit .............................................................................................................................. 869
A.2.
Printed circuit board of control unit .......................................................................................... 869
A.3.
LCD unit .................................................................................................................................. 870
A.4.
MDI unit ................................................................................................................................... 870
A.5.
Other units............................................................................................................................... 870
A.6.
Optical fiber cable ................................................................................................................... 871
xvii
Table of contents
B.
C.
B-64805EN/03
A.7.
Consumables .......................................................................................................................... 871
BIOS setup ............................................................................................................................................ 873
B.1.
Overview of "BIOS setup" ....................................................................................................... 873
B.2.
Key functions in setup screen ................................................................................................. 873
B.3.
Starting BIOS setup ................................................................................................................ 873
B.4.
Restoring the BIOS settings to factory default setting values .................................................. 874
B.5.
Exiting BIOS setup .................................................................................................................. 875
USB-Ethernet conversion unit................................................................................................................ 877
C.1.
Overview ................................................................................................................................. 877
C.2.
Connection configuration......................................................................................................... 877
Revision record ............................................................................................................ 880
xviii
I Equipment overview
B-64805EN/03
1.
Control unit and lcd unit hardware
Control unit and lcd unit hardware
This chapter describes the control unit and LCD unit hardware.
The following basic information is mainly provided.
• System-wide connections
Describes the configuration of the control unit.
For details, see "I.1.1. System configuration examples(P.3)".
For more details on connections, see "I.1.4. Overall connection diagram(P.42)".
• Hardware types and appearances
Describes the hardware connector layout, outline drawings, and the location of LEDs that need to be checked
when performing troubleshooting.
For details, see "I.1.2. Control Unit Hardware(P.7)" or "I.1.3. LCD unit hardware(P.39)".
NOTE
For details on replacement, see "V.1. Replacing control unit maintenance parts(P.667)".
• Precautions for the environment where the hardware will be installed
Provides information necessary when checking environmental conditions and cable laying conditions after
maintenance work.
For details, see "I.1.5. Installation environment(P.44)" or "I.1.6. Cautions related to grounding and noise(P.46)".
The LCD unit can also be connected to a unit other than the FANUC Series 500i-A control unit, such as FANUC
iPC.
This manual only describes FANUC Series 500i-A units.
Before performing maintenance work, identify the maintenance target and refer to the appropriate manual.
The name and specifications of the unit to be maintained can be found on the unit itself, e.g., engraved on the unit
itself.
For FANUC iPC maintenance, refer to "FANUC iPC FIP1000 Series CONNECTION AND MAINTENANCE
MANUAL" (B-64763EN).
1.1.
System configuration examples
This section describes examples of system configuration of the control unit.
1.1.1.
Control unit and LCD unit configuration
FANUC Series 500i-A consists of the following units.
• Control unit: controls operations of CNC, servo, and PMC
• LCD unit: displays the screen
• LCD control unit: controls the LCD unit
FANUC Series 500i-A can be roughly classified into two types according to the method of connection between the
control unit and LCD unit: LCD-mounted type control unit and stand-alone type control unit.
(Hereafter, an LCD-mounted type control unit is sometimes referred to as an "LCD-mounted type" and a stand-alone
type control unit as a "stand-alone type". )
3
Control unit and lcd unit hardware
B-64805EN/03
■LCD-mounted type: integrated control unit and LCD unit
In the LCD-mounted type configuration, the control unit is directly mounted onto a connector on the rear surface of
the LCD unit to integrate it with the LCD unit.
In the LCD-mounted type, functions that correspond to the LCD control unit are included in the control unit.
Fig. 1.1.1-1 Example of LCD-mounted type configuration
Part
Name
[A]
Control unit
[B]
LCD unit
■Stand-alone type configuration: separate control unit and LCD unit
In the stand-alone type configuration, the control unit and the LCD unit are mounted onto separate positions of the
cabinet. The control unit is mounted on the cabinet using a designated bracket. Further, the control unit and the LCD
unit are connected via the LCD control unit. The control unit and the LCD control unit are connected using a
communication cable.
4
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.1.1-2 Example of stand-alone type configuration
Part
Name
[A]
Control unit
[B]
LCD unit
[C]
LCD control unit
See "I.1.2. Control Unit Hardware(P.7)" for details on the mounting positions of various control unit maintenance parts,
mounting positions of various printed circuit board connectors, and mounting positions/indications of various printed
circuit board LEDs.
See "I.1.3. LCD unit hardware(P.39)" for details on the mounting positions/indications of the LCD unit LEDs.
1.1.2.
System Configuration Example of LCD-mounted Type Control Unit
A system configuration example of an LCD-mounted type control unit is shown in Fig. 1.1.2-1.
5
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.1.2-1 System configuration example of LCD-mounted type control unit
Part
Name
[A]
LCD-mounted type control unit + LCD unit
[B]
MDI unit
[C]
I/O unit
[D]
Machine operator's panel or high power circuit
[E]
Optical fiber cable
[F]
Servo amplifier
[G]
Servo motor
1.1.3.
System Configuration Example of Stand-alone Type Control Unit
A system configuration example of a stand-alone type control unit is shown in Fig. 1.1.3-1.
6
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.1.3-1 System configuration example of stand-alone type control unit
Part
[A]
[B]
[C]
[D]
[E]
[F]
[G]
[H]
1.2.
Name
Stand-alone Type Control Unit
MDI unit
I/O unit
Machine operator's panel or high power circuit
Optical fiber cable
Servo amplifier
Servo motor
LCD control unit and LCD unit
Control Unit Hardware
This section describes the mounting positions of various control unit maintenance parts, mounting positions of various
printed circuit board connectors, and mounting positions/indications of various printed circuit board LEDs.
There are two types of control unit models, depending on the number of optional board slots.
All models have board slots called expansion slots, separate from the optional board slot.
Table 1.2-1 Control unit models
Model
Number of optional board slots
0slot model
0
7
Control unit and lcd unit hardware
B-64805EN/03
Model
Number of optional board slots
2slot model
2
Control unit (0slot model)
The mounting positions of the maintenance parts of the control unit (0slot model) are shown in Fig. 1.2-1.
Fig. 1.2-1 0slot model outline drawing
Part
Name
Reference item
[A]
Main board
I.1.2.1. Main board(P.9)
[B]
Power supply board
I.1.2.4. Power supply
board(P.17)
[C]
Memory board
I.1.2.3. Memory board(P.15)
[D]
Expansion board
I.1.2.6. Expansion board(P.28)
[E]
Graphic board
I.1.2.5. Graphic board(P.19)
[F]
CPU board
I.1.2.2. CPU board(P.13)
[G]
Lithium battery
I.1.2.9. Lithium battery(P.37)
[H]
Fan unit (40 mm square fan x 2)
I.1.2.8. Fan Units and
Fans(P.35)
Boards installed should be selected to suit the system configuration. External appearance may differ depending on
the boards selected.
Control unit (2slot model)
The mounting positions of the maintenance parts of the control unit (2slot model) are shown in Fig. 1.2-2.
8
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2-2 2slot model outline drawing
Part
Name
Reference item
[A]
Main board
I.1.2.1. Main board(P.9)
[B]
Power supply board
I.1.2.4. Power supply
board(P.17)
[C]
Memory board
I.1.2.3. Memory board(P.15)
[D]
Expansion board
I.1.2.6. Expansion board(P.28)
[E]
Graphic board
I.1.2.5. Graphic board(P.19)
[F]
CPU board
I.1.2.2. CPU board(P.13)
[G]
Lithium battery
I.1.2.9. Lithium battery(P.37)
[H]
Fan unit (60 mm square fan x 1)
I.1.2.8. Fan Units and
Fans(P.35)
[I-1]
Optional board slot 1*1
I.1.2.7. Optional board(P.31)
[I-2]
Optional board slot 2*1
I.1.2.7. Optional board(P.31)
Boards installed should be selected to suit the system configuration. External appearance may differ depending on
the boards selected.
*1: If you do not use an optional board, be sure to install a blank panel (for optional slot).
1.2.1.
Main board
The specifications of the main board are shown in Table 1.2.1-1.
9
Control unit and lcd unit hardware
B-64805EN/03
Table 1.2.1-1 Main board specification
Name
Specifications
Main board A1
Main board A2
Main board A4
Remark
A17B-2101-0755
A17B-2101-0756
A17B-2101-0757
Connector mounting positions
The connector mounting positions on the main board are shown in Fig. 1.2.1-1.
Fig. 1.2.1-1 Main board connector mounting positions
Part
Connector
number
Connector
name
Function
[A]
[B]
COP24A-1
COP24A-2
FSSB-1
FSSB-2
FSSB interface
FSSB interface
[C]
[D]
[E]
[F]
[G]
[H]
[I]
JD72
JD51A
JD71
JD70A
JD70B
CS31A
CS01A
User I/O
I/O Link i
HDI
RS-232C-1
RS-232C-2
USB
ETHERNET
User I/O
I/O Link i
High-speed skip
Serial port
Serial port
USB
Ethernet
LED mounting positions
The LED mounting positions on the main board are shown in Fig. 1.2.1-2.
10
Remark
Not mounted on main
board A1
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.1-2 Main board LED mounting positions
Part
[A]
[B]
[C]
[D]
[E]
[F]
[G]
[H]
[I]
Name
LINK
ACT
ALARM0
ALARM1
ALARM2
ALARM3
ALARM4
HER5
STATUSF5
Color
Green
Yellow
Red
Red
Red
Red
Red
Red
Green
Purpose
Ethernet status
Alarm status
Ethernet status
LED indications
This section describes details on the main board LED indications.
NOTE
If the LEDs indicate a failure, see "IV.1. Troubleshooting(P.263)" for the appropriate action to be taken.
If the LEDs indicate that parts change is required, refer to "V.1. Replacing control unit maintenance parts(P.667)" for the
appropriate action to be taken.
The alarm status indications are shown in Table 1.2.1-2 and the Ethernet status indications are shown in Table 1.2.1-3.
1. Alarm status
Alarm status is indicated by a combination of five LED indications.
11
Control unit and lcd unit hardware
B-64805EN/03
Table 1.2.1-2 Alarm status indications
LED indications
ALARM
Unit status / action required
4
3
2
1
0
◇
□
■
□
◇
◇
■
□
■
◇
◇
■
□
□
◇
◇
■
■
□
◇
◇
■
■
■
◇
◇
◇
◇
◇
■
■
◇
◇
◇
◇
Low battery voltage is detected. If a battery is mounted, replace the
battery. If no battery is mounted, set bit 0 (BTC) of parameter No.
41700 to 1 to mask the battery alarm. For details of the parameter, see
"Series 500i-A PARAMETER MANUAL" (B-64810EN).
A failure was detected in the system. Take action according to the
alarm number displayed on the screen.
An error was detected in the data in the nonvolatile RAM on the
memory board. Replace the memory board. If the above action does
not solve the trouble, replace the main board.
An abnormality was detected in the power supply board. Replace the
power supply board.
A main board failure was detected. Replace the main board.
If this indication appears in the case of power-on, the CPU board is
being initialized. If this indication appears in other cases, a CPU board
failure was detected. Replace the CPU board. If the above action does
not solve the trouble, replace the main board.
Meaning of LED indications: ■=Lit, □=Off, ◇=Any
2. Ethernet status
Ethernet status is indicated by four LEDs: ACT / LINK / STATUSF / HER.
Table 1.2.1-3 Ethernet status indications
LED name
ACT
LED
indications
STATUSF5
HER5
12
Unit status / action required
□
No communication data
is being transmitted
Communication data is
being transmitted
Link is not established
■
A link is established
Peripheral equipment connection is not recognized
If no link is established while peripheral equipment is
connected, take one of the following measures:
Check the power status of HUB.
Check the connection between the control unit
and peripheral equipment.
Replace the main board, peripheral equipment,
and cables.
Peripheral equipment connection is recognized
□
Normal operation
Normal operation
☆
Device identification by
the Industrial Network
Setting Tool is in
progress or a Device
Blinking request by the
PROFINET function is
being received
□
Normal operation
When [Wink] is pressed on the [Select Device] screen
of the Industrial Network Setting Tool or when a
Device Blinking request for the PROFINET function is
received, the LED blinks for approximately 3 seconds
(turns on and off at intervals of approximately 0.5
seconds, repeated 3 times).
For details on the industrial network settings, refer to
"Series 500i-A Industrial Ethernet CONNECTION
MANUAL" (B-64803EN-6).
Normal operation
■
Malfunction (detected
by hardware)
□
■
LINK
Status
Waiting for data
Data is being sent/received
Malfunction caused by the faulty main board or a
noise.
Take one of the following actions:
B-64805EN/03
LED name
Control unit and lcd unit hardware
LED
indications
Status
Unit status / action required
Ensure that the cable is equipped with proper
noise suppression measures.
Replace the main board.
Meaning of LED indications: ■=Lit, □=Off, ☆=Blinking
Switch mounting positions
The switch mounting positions on the main board are shown in Fig. 1.2.1-3.
For information on setup and maintenance using push switches and rotary switches, see " VII.2. Maintenance operations
for the stand-alone type control unit(P.836)".
Fig. 1.2.1-3 Main board switch mounting positions
Part
Switch name
[A]
PSW (push switch)
[B]
MTSW (rotary switch)
1.2.2.
Switch applications
Used with MTSW (rotary switch) for configuration and
maintenance
Used with PSW (push switch) for configuration and
maintenance
CPU board
The specifications of the CPU board are shown in Table 1.2.2-1.
Table 1.2.2-1 CPU board specifications
Name
CPU board B1
CPU board C1
Specifications
A17B-2200-0102
A17B-2200-0104
Remark
Cannot be used with LCD-mounted type control units.
Connector mounting positions
The connector mounting positions on the CPU board are shown in Fig. 1.2.2-1.
13
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.2-1 CPU board connector mounting positions
Part
[A]
Connector
number
CA177
Connector
name
BATTERY
Function
Lithium battery
LED mounting positions
The LED mounting positions on the CPU board are shown in Fig. 1.2.2-2.
14
Reference item
V.1.5. Replace Battery for
Clock Function in Control
Unit(P.731)
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.2-2 CPU board LED mounting positions
Part
[A]
1.2.3.
Name
ALARM
Color
Purpose
Red
CPU reset state
LED indications
Lit: Reset state
Unlit: Reset canceled
Memory board
The specifications of the memory board are shown in Table 1.2.3-1.
Table 1.2.3-1 Memory board specifications
Name
Memory board A12
Memory board A13
Memory board A14
Specifications
Remark
A20B-2201-0051
A20B-2201-0052
A20B-2201-0310
Connector mounting positions
The connector mounting positions on the memory board are shown in Fig. 1.2.3-1.
15
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.3-1 Memory board connector mounting positions
Part
[A]
Connector
number
CS11A
Connector
name
SD CARD
Function
Remark
SD Card
SD card that can be connected to memory board
The SD card that can be connected to the SD card connector on the memory board is the same as the SD card that
can be connected to the SD card slot on the LCD unit.
See I.2.1. SD Card(P.55).
Do not remove the SD card or turn off the control unit power while accessing the SD card.
There is a risk of corruption or loss of data on the SD card.
16
B-64805EN/03
Control unit and lcd unit hardware
NOTE
Regarding the functions that use SD cards, the functions available are different when connected to the memory
board and when connected to the LCD unit. For details, see the explanation of each function.
SD cards purchased from third parties are not guaranteed to work with the SD card slot.
When inserting an SD card, check that the write-protect switch on the SD card is set as intended.
1.2.4.
Power supply board
The specifications of the power supply board are shown in Table 1.2.4-1.
Table 1.2.4-1 Power supply board specifications
Name
Power supply board
Specifications
Remark
A20B-2201-0020
Connector mounting positions
The connector mounting positions on the power supply board are shown in Fig. 1.2.4-1.
17
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.4-1 Power supply board connector mounting positions
Part
Connector
number
Connector
name
Function
[A]
CPD34A
24 VDC (IN)
Power supply input to control unit*1
[B]
CPD34B
24 VDC (OUT)
Power supply output from control unit*1
Remark
*1: Two cables are connected to one power supply connector. Therefore, two connector numbers are assigned.
CPD34A is for the power supply input to the control unit, and CPD34B is for the power supply output from the control
unit.
LED mounting positions
The LED mounting positions on the power supply board are shown in Fig. 1.2.4-2.
18
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.4-2 Power supply board LED mounting positions
Part
Name
Color
Purpose
LED indications
[A]
FU1
Red
24V fuse (FU1) status
Lit: Fuse is blown
[B]
ALARM 1
Red
[C]
ALARM 2
Red
Main board power status and main board
processor temperature status
CPU board power status
Lit: Power failure or abnormal
temperature
Lit: Power failure
[D]
ALARM 3
Red
Graphic board power status
Lit: Power failure
[E]
ALARM 4
Red
Memory board power status
Lit: Power failure
[F]
ALARM 5
Red
Expansion board power status
Lit: Power failure
[G]
ALARM 6
Red
Lit: Power failure
[H]
ALARM 7
Red
Optional board power status (for slots 1 to
2)
Power supply board power status
[I]
FU2
Red
24V fuse (FU2) status
Lit: Fuse is blown
1.2.5.
Graphic board
1.2.5.1.
FANUC iPC graphic board (FIP 1110)
Lit: Power failure
The specifications of the FANUC iPC Graphic Board (FIP 1110) are shown in Table 1.2.5.1-1.
Table 1.2.5.1-1 FANUC iPC Graphic Board (FIP 1110)
Name
FANUC iPC graphic board (FIP1110)
Specifications
Remark
A17B-2200-0200
Connector mounting positions
The connector mounting positions on FANUC iPC Graphic Board (FIP 1110) are shown in Fig. 1.2.5.1-1.
19
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.5.1-1 FANUC iPC Graphic Board (FIP 1110) connector mounting positions
Part
Connector
number
Connector
name
Function
[A]
CD65
MDI
MDI
[B]
CS22A
USB
USB
[C]
CS02A
ETHERNET
Ethernet
LED mounting positions
The LED mounting positions on FANUC iPC Graphic Board (FIP 1110) are shown in Fig. 1.2.5.1-2.
20
Remark
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.5.1-2 FANUC iPC Graphic Board (FIP 1110) LED mounting positions
Part
[A]
[B]
[C]
[D]
[E]
[F]
[G]
Name
RSMRST_N
IERR
SATA
MCERR
CORE_PWR
LINK
ACT
Color
Green
Red
Green
Red
Green
Green
Yellow
Purpose
Reset state
CPU internal error
Storage status
Memory error
CPU core power status
Ethernet status
LED indications
This section describes the FANUC iPC Graphic Board (FIP 1110) LED indications.
NOTE
If the LEDs indicate a failure, see "IV.1. Troubleshooting(P.263)" for the appropriate action to be taken.
If the LEDs indicate that parts change is required, refer to "V.1. Replacing control unit maintenance parts(P.667)" for the
appropriate action to be taken.
The CPU status indications are shown in Table 1.2.5.1-2 and the Ethernet status indications are shown in Fig. 1.2.5.1-3.
21
Control unit and lcd unit hardware
B-64805EN/03
1. CPU status
Table 1.2.5.1-2 CPU status indications
LED
indications
LED name
CORE_PWR
MCERR
SATA
IERR
RSMRST_N
Status
Unit status/action required
□
Power OFF
■
Power ON
Power-off state
If the power supply board detects a graphic board
power failure, replace the FANUC iPC Graphi Board
(FIP 1110).
Normal state
□
Normal state
Normal state
■
Memory error
□
No access
Error in DRAM
Replace the FANUC iPC Graphic Board (FIP 1110).
No access to storage
■
Accessing
Access to storage in progress
□
Normal state
Normal state
■
CPU internal error
□
Reset state
■
Reset canceled state
Error inside CPU
Replace the FANUC iPC Graphic Board (FIP 1110).
Reset or shutdown state
If the reset is not canceled upon power-up even
though CORE_PWR is in the power-on state, replace
the FANUC iPC Graphic Board (FIP 1110).
Reset canceled state
Meaning of LED indications: ■=Lit, □=Off
2. Ethernet status
Ethernet status is indicated by two LEDs: ACT / LINK.
Fig. 1.2.5.1-3 Ethernet status indications
LED name
ACT
LED
indications
□
No communication data
is being transmitted
Communication data is
being transmitted
Link is not established
■
A link is established
□
■
LINK
Status
Unit status / action required
Waiting for data
Data is being sent/received
Peripheral equipment connection is not recognized
If no link is established while peripheral equipment is
connected, take one of the following measures:
Check the power status of HUB.
Check the connection between the control unit
and peripheral equipment.
Replace the main board, peripheral equipment,
and cables.
Peripheral equipment connection is recognized
Meaning of LED indications: ■=Lit, □=Off
1.2.5.2.
Interface board A
The specifications of the interface board A are shown in Table 1.2.5.2-1.
22
B-64805EN/03
Control unit and lcd unit hardware
Table 1.2.5.2-1 Interface board A specifications
Name
Specifications
Interface board A
Remark
A20B-2201-0370
Connector mounting positions
The connector mounting positions on the interface board A are shown in Fig. 1.2.5.2-1.
Fig. 1.2.5.2-1 Interface board A connector mounting positions
Part
[A]
Connector
number
CS01B
Connector
name
ETHERNET
Function
Remark
Ethernet
LED mounting positions
The LED mounting positions on the interface board A are shown in Fig. 1.2.5.2-2.
23
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.5.2-2 Interface board A LED mounting positions
Part
Name
Color
Purpose
[A]
7 Segment LED
Red
Control unit status
[B]
LINK
Green
Ethernet status
[C]
ACT
Yellow
LED indications
This section describes details on the interface board A LED indications.
NOTE
If the LEDs indicate a failure, see "IV.1. Troubleshooting(P.263)" for the appropriate action to be taken.
If the LEDs indicate that parts change is required, refer to "V.1. Replacing control unit maintenance parts(P.667)" for the
appropriate action to be taken.
1. Control unit status
The status of the control unit is indicated by the 7-segment LED.
The 7-segment LED indication changes according to the status of the control unit.
The 7-segment LED has a number section and a dot section, each of which is independent of the other. The
status indications in the dot section are shown in Table 1.2.5.2-2, and the status indications in the number section
are shown in Table 1.2.5.2-3.
Table 1.2.5.2-2 Control unit status indications in the dot section
7-segment LED
indications
Lit/blinkin
g
Lit
Status
Unit status / action required
Control unit is not connected to
LCD control unit
If the LCD control unit is connected to the
connector CS01B but the light still turns on, check
the Ethernet cable and the connection between the
power supply and the LCD control unit.
Table 1.2.5.2-3 Control unit status indications in the number section
7-segment LED
indications
Lit/blinkin
g
ー
24
Status
Unit status / action required
Power is not turned on (poweroff state)
If the unit stops with this indication even though the
power is turned on, check the power connection. If
an LED on the power supply board is lit, replace
the board corresponding to the LED. See to
"I.1.2.4. Power supply board(P.17)".
Also, if a system alarm is triggered due to a drop in
fan speed, replace the fan.
B-64805EN/03
7-segment LED
indications
Control unit and lcd unit hardware
Lit/blinkin
g
Status
Unit status / action required
Lit
CNC completed initialization
and is ready for operation
Normal operation is in progress.
Lit
Main board boot process
started
Initialization process for the main board and other
devices on the board is in progress.
Lit
Main board boot process initialization completed
If the unit stops with this indication, replace the
main board.
Lit
System software initialization
started
If the system does not work with this indication, the
system software, memory board, CPU board, or
main board may be defective. Reinstall the system
software. If the problem persists, replace the
memory board, CPU board, or main board.
Blinking
System software initialization
error
If the system does not work with this indication, it
has failed to load the system software from the
memory board.
Replace the memory board.
Lit
System software initialization in
progress
Blinking
Nonvolatile memory data is
being initialized
(During initialization of
nonvolatile memory, P, 2, 3, 4,
and 5 blink in this order. )
Lit
System software initialization in
progress
If the system does not work with this indication,
there may be a data error in the nonvolatile
memory on the memory board.
Perform all-clear for the nonvolatile memory on the
memory board. For the all-clear procedure, see
VII.3.2.6. Boot Screen(P.846) or VII.2.2. Operation
method(P.836).
Nonvolatile memory data on the memory board is
being initialized.
If the system does not work with this indication, the
memory board may be defective.
Replace the memory board.
System software initialization is in progress.
Blinking
Nonvolatile memory data is
being initialized
(During initialization of
nonvolatile memory, P, 2, 3, 4,
and 5 blink in this order. )
Lit
System software initialization in
progress
Blinking
Nonvolatile memory data is
being initialized
(During initialization of
nonvolatile memory, P, 2, 3, 4,
and 5 blink in this order. )
Nonvolatile memory data on the memory board is
being initialized.
If the system does not work with this indication, the
memory board may be defective.
Replace the memory board.
System software initialization is in progress.
Nonvolatile memory data on the memory board is
being initialized.
If the system does not work with this indication, the
memory board may be defective.
Replace the memory board.
25
Control unit and lcd unit hardware
7-segment LED
indications
26
Lit/blinkin
g
Status
B-64805EN/03
Unit status / action required
Lit
System software initialization in
progress
System software initialization is in progress.
Blinking
Nonvolatile memory data is
being initialized
(During initialization of
nonvolatile memory, P, 2, 3, 4,
and 5 blink in this order. )
Lit
System software initialization in
progress
Nonvolatile memory data on the memory board is
being initialized.
If the system does not work with this indication, the
memory board may be defective.
Replace the memory board.
System software initialization is in progress.
Lit
System software initialization in
progress
System software initialization is in progress.
Lit
Immediately after power-on
If the system does not work with this indication, the
main board may be defective.
Replace the main board.
Lit
Main board boot process
completed
Blinking
Error in connection with the
optional board
If the system does not work with this indication, the
system software or memory board may be
defective.
Reinstall the system software. If the above action
does not solve the trouble, replace the memory
board.
The software for the optional board may be
defective.
Replace the optional board software. If the above
action does not solve the trouble, replace the
optional board.
Lit
System abnormality
Blinking
System alarm occurred
Lit
Error during the main board
boot process
This alarm may be due to a main board fault.
Replace the main board.
Lit
System software loading in
progress
If the system does not work with this indication, the
memory board may be defective.
Replace the memory board.
A system abnormality has occurred. After a certain
period of time (approx. 10 seconds), "E" blinks.
If the indication does not change to a blinking
display after a certain period of time, an error has
occurred during boot software execution. The
memory board may be defective.
Replace the memory board.
Check the system alarm screen for details of the
error. See to "IV.1.22. System alarms(P.309)".
B-64805EN/03
7-segment LED
indications
Control unit and lcd unit hardware
Lit/blinkin
g
Status
Unit status / action required
Lit
Fan motor failure in the control
unit
The fan motor in the control unit may be defective.
Check for poor connection of the fan motor. If there
is no connection defect, replace the fan motor.
Lit
System software initialization in
progress
Blinking
Nonvolatile memory data is
being initialized
(During initialization of
nonvolatile memory, P, 2, 3, 4,
and 5 blink in this order. )
If the system does not work with this indication, the
system software or memory board may be
defective.
Reinstall the system software. If the above action
does not solve the trouble, replace the memory
board.
If the system does not work with this indication, the
memory board may be defective.
Replace the memory board.
Lit
CNC BOOT in progress
Communication with CNC BOOT is in progress.
When CNC BOOT is terminated, the LED
indication changes.
Sequential
ly lit
Automatic operation or backup
in progress
Automatic operation is in progress.
Or, the function to back up to a file is in operation.
Illuminated part
rotates to the
right
NOTE
If MTSW (rotary switch) on the main board is set to a value other than "0", the indication and status will be different from
the above.
MTSW (rotary switch) is used for maintenance. See to "VII.2. Maintenance operations for the stand-alone type control
unit(P.836)".
2. Ethernet status
Ethernet status is indicated by two LEDs: ACT / LINK.
Table 1.2.5.2-4 Indications of Ethernet status of interface board
LED name
ACT
LED
indications
□
No communication data
is being transmitted
Communication data is
being transmitted
Link is not established
■
A link is established
□
■
LINK
Status
Unit status / action required
Waiting for data
Data is being sent/received
Peripheral equipment connection is not recognized
If no link is established while peripheral equipment is
connected, take one of the following measures:
Check the power status of HUB.
Check the connection between the control unit
and peripheral equipment.
Replace the main board, peripheral equipment,
and cables.
Peripheral equipment connection is recognized
Meaning of LED indications: ■=Lit, □=Off
27
Control unit and lcd unit hardware
1.2.6.
Expansion board
1.2.6.1.
Ethernet expansion board B
B-64805EN/03
The specifications of the Ethernet expansion board B are shown in Table 1.2.6.1-1.
Table 1.2.6.1-1 Ethernet expansion board B specifications
Name
Ethernet expansion board B
Specifications
A20B-2201-0061
Connector mounting positions
The connector mounting positions on the Ethernet expansion board B are shown in Fig. 1.2.6.1-1.
28
Remark
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.6.1-1 Ethernet expansion board B connector mounting positions
Part
Connector
number
Connector
name
Function
[A]
CS01C
ETHERNET
Ethernet
[B]
CS01D
ETHERNET
Ethernet
Remark
LED mounting positions
The LED mounting positions on the Ethernet expansion board B are shown in Fig. 1.2.6.1-2.
29
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.6.1-2 Ethernet expansion board B LED mounting positions
Part
[A]
[B]
[C]
[D]
[E]
[F]
[G]
[H]
Name
HER1
STATUSF1
LINK
ACT
HER2
STATUSF2
LINK
ACT
Color
Red
Green
Green
Yellow
Red
Green
Green
Yellow
Purpose
Ethernet status (connector number: CS01C)
Ethernet status (connector number: CS01D)
LED indications
This section describes details on the Ethernet expansion board B LED indications.
NOTE
If the LEDs indicate a failure, see "IV.1. Troubleshooting(P.263)" for the appropriate action to be taken.
If the LEDs indicate that parts change is required, refer to "V.1. Replacing control unit maintenance parts(P.667)" for the
appropriate action to be taken.
The Ethernet status indications are shown in Table 1.2.6.1-2.
Ethernet status is indicated by four LEDs: ACT / LINK / STATUSF / HER.
Table 1.2.6.1-2 Ethernet status indications
LED name
ACT
LED
indications
□
■
30
Status
No communication data
is being transmitted
Communication data is
being transmitted
Unit status / action required
Waiting for data
Data is being sent/received
B-64805EN/03
LED name
Control unit and lcd unit hardware
LED
indications
Status
Unit status / action required
□
Link is not established
■
A link is established
Peripheral equipment connection is not recognized
If no link is established while peripheral equipment is
connected, take one of the following measures:
Check the power status of HUB.
Check the connection between the control unit
and peripheral equipment.
Replace the main board, peripheral equipment,
and cables.
Peripheral equipment connection is recognized
□
Normal operation
Normal operation
☆
Device identification by
the Industrial Network
Setting Tool is in
progress or a Device
Blinking request by the
PROFINET function is
being received
□
Normal operation
When [Wink] is pressed on the [Select Device] screen
of the Industrial Network Setting Tool or when a
Device Blinking request for the PROFINET function is
received, the LED blinks for approximately 3 seconds
(turns on and off at intervals of approximately 0.5
seconds, repeated 3 times).
For details on the industrial network settings, refer to
"Series 500i-A Industrial Ethernet CONNECTION
MANUAL" (B-64803EN-6).
Normal operation
■
Malfunction (detected
by hardware)
LINK
STATUSF1
or
STATUSF2
HER1
or
HER2
Malfunction caused by the faulty main board or a
noise.
Take one of the following actions:
Ensure that the cable is equipped with proper
noise suppression measures.
Replace the main board.
Meaning of LED indications: ■=Lit, □=Off, ☆=Blinking
1.2.7.
Optional board
1.2.7.1.
Storage Expansion Board
The storage expansion board is used to expand the storage of the FANUC iPC graphic board. One M.2 SATA SSD is
installed on the board.
The specifications of the storage expansion board are shown in Table 1.2.7.1-1, and the connectable optional board
slots are shown in Table 1.2.7.1-2.
Table 1.2.7.1-1 Storage expansion board specifications
Name
Storage Expansion Board
Specifications
Remark
A20B-2201-0360
Table 1.2.7.1-2 Allows connection of storage expansion board
Model
2slot model
Slot which allows connection
Slot 2
Connector mounting positions
The connector mounting positions on the storage expansion board are shown in Fig. 1.2.7.1-1.
31
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.7.1-1 Storage expansion board connector mounting positions
Part
[A]
Connector
number
Connector
name
CA170
1.2.7.2.
M.2SSD
Function
Remark
M.2 SATA SSD
PROFIBUS-DP board
The PROFIBUS-DP board is used for PROFIBUS-DP master/device communication. For details on how to use it, see
"Series 500i-A Fieldbus (PROFIBUS) CONNECTION MANUAL" (B-64803EN-7).
The specifications of the PROFIBUS-DP board is shown in Table 1.2.7.2-1, and the optional board slot to which the
PROFIBUS-DP board can be connected is shown in Table 1.2.7.2-2.
Table 1.2.7.2-1 PROFIBUS-DP board specifications
Name
PROFIBUS-DP board
Specifications
Remark
A20B-2103-0700
Table 1.2.7.2-2 Slot which allows connection of PROFIBUS-DP board
Model
2slot model
32
Slot which allows connection
Slot1, Slot2
B-64805EN/03
Control unit and lcd unit hardware
Connector mounting positions
The connector mounting positions on the PROFIBUS-DP board are shown in Fig. 1.2.7.2-1.
Fig. 1.2.7.2-1 PROFIBUS-DP board connector mounting positions
Part
[A]
Connector
number
CD74
Connector name
PROFIBUS
Function
PROFIBUS-DP master/device
Reference item
-
LED mounting positions
The LED mounting positions on the PROFIBUS-DP board are shown in Fig. 1.2.7.2-2.
33
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.7.2-2 PROFIBUS-DP board LED mounting positions
Part
[A]
[B]
[C]
[D]
Name
Color
RDY
RUN
ERR
STA
Orange
Green
Red
Green
Purpose
System startup status
Status
LED indications
This section describes details on the PROFIBUS-DP board LED indications.
NOTE
If the LEDs indicate a failure, see"Series 500i-A Fieldbus (PROFIBUS) CONNECTION MANUAL" (B-64803EN-7)
for the appropriate action to be taken.
If the LEDs indicate that parts change is required, see "V.1. Replacing control unit maintenance parts(P.667)" for the
appropriate action to be taken.
The status display on the PROFIBUS-DP board is shown in Table 1.2.7.2-3.
Table 1.2.7.2-3 PROFIBUS-DP status display
LED name
RDY
LED
indications
□
■
or
Status
System startup
complete
System startup not
complete
☆
RUN
34
□
System startup not
complete
Unit status / action required
System startup is complete.
System startup has not completed.
Check the Log screen for more detailed information
about the error that has occurred. For details about the
Log screen, see "Series 500i-A Fieldbus (PROFIBUS)
CONNECTION MANUAL" (B-64803EN-7).
System startup has not completed.
B-64805EN/03
Control unit and lcd unit hardware
LED
indications
LED name
Status
or
☆
■
ERR
□
STA
System startup
complete
Normal operation
Unit status / action required
Check the Log screen for more detailed information
about the error that has occurred. For details about the
Log screen, see "Series 500i-A Fieldbus (PROFIBUS)
CONNECTION MANUAL" (B-64803EN-7).
System startup is complete.
Normal operation
When master function is used
■
Communication error
occurred
☆
Communication error
occurred
□
No communication
Communication errors have occurred with all
devices. Check the Log screen for detailed
information. For details about the Log screen,
see "Series 500i-A Fieldbus (PROFIBUS)
CONNECTION MANUAL" (B-64803EN-7).
When device function is used
Device configuration information is incorrect.
Check the Log screen. For details about the Log
screen, see "Series 500i-A Fieldbus (PROFIBUS)
CONNECTION MANUAL" (B-64803EN-7).
When master function is used
Communication errors have occurred with one or
more devices. Check the Log screen for detailed
information. For details about the Log screen,
see "Series 500i-A Fieldbus (PROFIBUS)
CONNECTION MANUAL" (B-64803EN-7).
When device function is used
A communication error has occurred with the
master. Check the Log screen. For details about
the Log screen, see "Series 500i-A Fieldbus
(PROFIBUS) CONNECTION MANUAL" (B64803EN-7).
No communication
■
Normal communication
Normal communication
☆
Setting error
When master function is used
Setting information has not been downloaded to
CNC from the setting tool.
When device function is used
The master that is the communication partner is
in "Clear" mode.
Meaning of LED indications: ■=Lit, □=Off, ☆=Blinking
1.2.8.
Fan Units and Fans
The specifications of the fan units and fans are shown in Table 1.2.8-1.
Table 1.2.8-1 Fan unit and fan specifications
Name
Fan unit (0slot model)
Fan unit (2slot model)
2 x 40mm square fans
1 x 60mm square fan
Ordering specification
A02B-0370-C100
A02B-0370-C102
A02B-0370-K120
(Parts specifications: 2 x A90L-00010633#A)
A02B-0370-K121
(Parts specifications: A90L-00010634#A)
Remark
Fan case + 2 x 40mm square fans
Fan case + 60mm square fan
For 0slot models
For 2slot models
35
Control unit and lcd unit hardware
B-64805EN/03
Fan unit (0slot model)
An outline drawing of the fan unit (0slot model) is shown in Fig. 1.2.8-1.
Fig. 1.2.8-1 Fan unit (0slot model) outline drawing
Part
Name
[A]
Fan case (0slot model)
[B]
2 x 40mm square fans
Fan unit (2slot model)
An outline drawing of the fan unit (2slot model) is shown in Fig. 1.2.8-2.
36
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.8-2 Fan unit (2slot model) outline drawing
Part
[A]
[B]
Name
Fan case (2slot model)
60mm square fan
1.2.9.
Lithium battery
The specifications of the lithium battery are shown in Table 1.2.9-1.
Table 1.2.9-1 Lithium battery specifications
Name
Battery box
Battery case
Battery cable
Ordering specification
A02B-0370-K101 (parts specifications: A98L-0005-0814)
A02B-0236-C282
A02B-0370-K103 (parts specifications: A660-2042-T585#L14R03)
An outline drawing of the lithium battery is shown in Fig. 1.2.9-1 and a outline drawing of the battery case is shown in
Fig. 1.2.9-2.
37
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.2.9-1 Lithium battery outline drawing
Part
Name
[A]
Latch (battery cover)
[B]
Battery box
[C]
Battery cover
[D]
Lithium coin battery*1
*1: Attach it so that the positive polarity faces the end.
38
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.2.9-2 Battery case outline drawing
Part
[A]
[B]
[C]
[D]
Name
Battery case (body)
Holes for attaching (four places)
Two alkaline (size D) batteries
Battery case (cover)
*1: The cable connection terminal is on the back side of the battery case.
1.3.
LCD unit hardware
This section describes the LCD unit connector mounting positions and LED mounting positions/indications.
The specifications of the LCD unit are shown in Table 1.3-1.
LCD unit models are available in five screen sizes: 10.4-inch, 15-inch, 18.5-inch, 21.5-inch, and 24-inch.
Table 1.3-1 LCD unit specifications
Model (name)
10.4-inch LCD unit
15-inch LCD unit
18.5-inch LCD unit
21.5-inch LCD unit
24-inch LCD unit
Unit size
Width × Height
Touch
Panel
290 mm × 220
mm
375 mm × 290
mm
485 mm × 290
mm
545 mm × 325
mm
605 mm × 355
mm
Equippe
d
Equippe
d
Equippe
d
Equippe
d
Equippe
d
Horizontal
soft keys
Number of
switches
Vertical soft
keys
Number of
switches
Ordering specification
None
None
A02B-0370-C020
None
None
A02B-0370-C030
None
None
A02B-0370-C060
None
None
A02B-0370-C040
None
None
A02B-0370-C050
39
Control unit and lcd unit hardware
1.3.1.
B-64805EN/03
LCD unit
An outline drawing of the LCD unit with touch panel is shown in Fig. 1.3.1-1.
Fig. 1.3.1-1 LCD unit with touch panel (10.4-inch 290 mm x 220 mm) outline drawing
Part
Name
[A]
LCD, touch panel
[B]
SD card slot
[C]
USB port
NOTE
The figure shows a typical size. For other sizes of LCD units, the component names are the same.
1.3.2.
LED Mounting Positions and LED Indications on LCD Unit
This section describes the LED mounting positions and LED indications on the LCD unit.
LED mounting positions
The LED mounting positions are shown in Fig. 1.3.2-1.
The LEDs on the LCD unit are mounted near the back of the SD card slot and USB port.
The LED mounting positions / LED types / number of LEDs is the same regardless of the LCD unit model.
40
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.3.2-1 LCD unit LED mounting positions
Part
Name
LED color
Remark
[A]
7 Segment LED
Red
Control unit status
[B]
ALM0
Red
Alarm status
[C]
ALM1
Red
[D]
ALM2
Red
[E]
ALM3
Red
[F]
ALM4
Red
[G]
STATUS
Yellow
Control unit status
LED indications
LED indications on the LCD unit vary depending on the unit connected.
For details on the LED indications, refer to the manual of the unit to be connected.
When connecting to an LCD-mounted type control unit
Table 1.3.2-1 LCD unit LED indication reference list
LED name
7 Segment LED
ALM0
ALM1
ALM2
ALM3
ALM4
STATUS
Reference
Dot section: Table 1.3.2-2
Numeric section: I.1.2.5.2. Interface board A(P.22) Table 1.2.5.2-3(P.24)
I.1.2.1. Main board(P.9) - LED indication - Alarm status - ALARM0
I.1.2.1. Main board(P.9) - LED indication - Alarm status - ALARM1
I.1.2.1. Main board(P.9) - LED indication - Alarm status - ALARM2
I.1.2.1. Main board(P.9) - LED indication - Alarm status - ALARM3
I.1.2.1. Main board(P.9) - LED indication - Alarm status - ALARM4
Blinking: Main board and graphic board are communicating
41
Control unit and lcd unit hardware
B-64805EN/03
Table 1.3.2-2 Control unit status indications in the dot section
7-segment LED
indications
Lit/blinkin
g
Lit
Status
Unit status / action required
Main board and graphic board
are not connected
The cause may be a main board or graphic board
failure. Replace the main board or graphic board.
When connecting with FANUC iPC
See "FANUC iPC FIP1000 Series CONNECTION AND MAINTENANCE MANUAL" (B-64763EN).
1.3.3.
LCD unit precautions
The following are precautions to be taken when using the LCD unit.
Be sure to ground the LCD unit with a ground wire.
Do not hit the touch panel with strong force or use hard objects to operate the panel. It may lead to breakage or
damage of the glass. With the capacitive touch panel, you do not need to press the panel to input but just touch
the keys.
NOTE
Turn the power ON after making sure that the touch panel is free from dirt and water droplets.
Initialization is performed for 7 seconds after the power is turned on. Do not bring your fingers or conductive
objects such as metal close to the touch panel or touch it with them.
Wipe off any dirt or water droplets on the touch panel with a soft cloth.
The touch panel doesn't respond to fingernails, so please operate it with your finger. Also, when you wear gloves,
the touch panel may become slow to respond and may not operate smoothly.
The LCD is manufactured using extremely precise processing technology, and due to its characteristics, some
pixels may fail to light up or stay lit up all the time.
Please note that these phenomena do not indicate device failure.
The backlight used in the LCD is a part with a life span, so its brightness will decrease after a long period of use.
The component we use is designed with factory automation in mind and has a long life span. However, depending
on the environment in which it is used (in particular, the operating temperature), the decrease in brightness may
accelerate and it may come to have difficulty lighting up.
Turning off the screen when not in use reduces the actual brightness reduction.
However, this is only effective if the display is off for more than 30 minutes at a time, so do not turn the display on
and off frequently.
Due to the structure of the LCD panel, if the same image is displayed continuously for a long time, image burn-in
(wherein even if the image is switched, contents of the image displayed for a long time remain displayed) may
occur.
Turning off the screen via the display's power settings is also effective in reducing the burn-in phenomenon.
1.4.
Overall connection diagram
This section describes a schematic connection between the control unit and external equipment.
Fig. 1.4-1 shows overall connections with external devices for the LCD-mounted type control unit and Fig. 1.4-2 shows
those for the stand-alone type control unit.
Connections for the control unit, the MDI unit, and the LCD unit differ between the LCD-mounted type control unit and
the stand-alone type control unit.
42
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.4-1 Overall connection diagram (1): LCD-mounted type control unit
*1: An example of a connection with a single-axis amplifier is shown.
*2: Absolute batteries are only necessary when an absolute scale is being used.
*3: Connection with the Ethernet is possible by installing the FANUC iPC graphic board.
43
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.4-2 Overall connection diagram (2): Stand-alone type control unit
*1: An example of a connection with a single-axis amplifier is shown.
*2: Absolute batteries are only necessary when an absolute scale is being used.
1.5.
Installation environment
The environmental conditions for outside the cabinet and the control unit installation requirements are described.
44
B-64805EN/03
1.5.1.
Control unit and lcd unit hardware
Environmental Conditions for Cabinet Installation
The control unit and the peripheral units have been designed on the assumption that they will be housed in closed
cabinets.
In this manual "cabinet" refers to the following:
• A cabinet manufactured by the machine tool builder for housing the control unit or peripheral units;
• A pendant box-type cabinet manufactured by the machine tool builder for housing the LCD unit, MDI unit, or
operator's panel;
• Anything equivalent to the above.
The following table, Table 1.5.1-1, lists the environmental requirements for installing these cabinets.
Table 1.5.1-1 Environmental requirements for installation of the cabinet
Item
Specifications
Cabinet
Ambient
temperature
Operating
Nonoperating
(including storage and
transportation):
Temperature change
Humidity
Usual
Short period (less than
1 month)
Vibration
Operating
Nonoperating
(including storage and
transportation):
Meters above
Operating
sea level
Nonoperating
(including storage and
transportation):
Surrounding environment
0 to 45°C
-20 to 60°C
0.3°C/minute or less
75% RH or less, no condensation
95% RH or less, no condensation
4.9m/s2 (0.5G) or less
9.8 m/s2 (1.0 G) or less
Up to 1,000 m*1
Up to 12000 m
Normal machine shop environment (The environment must be considered if
the cabinets are in a location where the density of dust, coolant, organic
solvent, corrosive gas, and/or the like is relatively high.)
*1: If the cabinet is installed more than 1,000 m above sea level, the allowable upper ambient temperature of the
control unit housed in the cabinet changes.
See to "I.1.5.2. Installation conditions of the control unit(P.45)".
1.5.2.
Installation conditions of the control unit
The installation requirements for the control unit are shown in Table 1.5.2-1.
Table 1.5.2-1 Installation conditions of the control unit
Item
Ambient
temperature
Humidity
Vibration
Operating
Nonoperating
(including storage and
transportation):
Temperature change
Usual
Short period (less than
1 month)
Operating
Specifications
LCD-mounted type control unit and LCD unit: 0 to 58°C
Stand-alone type control unit: 0 to 55°C
-20 to 60°C
0.3°C/minute or less
75% RH or less, no condensation
95% RH or less, no condensation
4.9 m/s2 (0.5 G) or less. FANUC's evaluation test was conducted under the
following conditions complying with IEC 60068-2-6:
10 to 58 Hz: 0.075 mm (amplitude)
45
Control unit and lcd unit hardware
B-64805EN/03
Item
Specifications
58 to 500 Hz: 9.8m/s2 (1.0 G)
Nonoperating
(including storage and
transportation):
Meters above
Operating
sea level
Nonoperating
(including storage and
transportation):
Surrounding environment
Direction of vibration: Each of the X, Y, and Z directions
Number of sweep cycles: 10
9.8 m/s2 (1.0 G) or less
Up to 1,000 m*1
Up to 12000 m
Coolant, lubricant, cutting chips, and the like must not be sprinkled directly
over the equipment. No corrosive gas shall be allowed.
*1: If it is installed more than 1,000 m above sea level, the allowable upper ambient temperature of the control unit
changes.
For each 100 m over 1,000 m above sea level, the allowable upper ambient temperature of the control unit drops by
1.0°C.
Example:
When a control unit whose allowable operating ambient temperature range is 0°C to 58°C is used 1,750 m above sea
level:
58℃ - (1750m - 1000m) / 100m × 1.0℃ = 50.5℃
Therefore, the allowable ambient temperature range is from 0°C to 50.5°C.
NOTE
When using a unit with other installation condition requirements, be sure to meet those requirements as well.
1.6.
Cautions related to grounding and noise
The cabinets generally have measures against electrical shocks and noise, such as connecting grounding wires and
separating cables on routing in them.
This section describes the cable isolation policies as precautions for grounding and noise.
If you removed grounding wires from the cabinet, for example, in replacing a control or peripheral unit in the cabinet or if
you temporarily changed the way other cables are laid or bound, restore their original state of connection after
maintenance work.
Failure to properly restore the original connection may result in electric shock or unit malfunction due to noise.
1.6.1.
Separating Cables
The cables used for the CNC machine tool systems are classified as listed in Table 1.6.1-1.
Process the cables in each group as described in the action column.
Table 1.6.1-1 Cable grouping
46
Group
Signal line
Action
A
Primary AC power line
Secondary AC power line
AC/DC power lines (containing the power lines for
the servo and spindle motors)
AC/DC solenoid
Bind the cables in group A separately*1 from groups
B and C, or cover group A cables with an
electromagnetic shield*2.
See I.1.6.2. Surge Absorber(P.48) and connect spark
killers or diodes with the solenoid and relay.
B-64805EN/03
Group
B
C
Control unit and lcd unit hardware
Signal line
Action
AC/DC relay
DC solenoid (24V DC)
DC relay (24V DC)
DI/DO cable between the I/O unit and control
cabinet
DI/DO cable between the I/O unit and machine
24V DC input power supply cables connected to
the control unit and its peripherals
I/O Link i cable
Cable for the position coder
Cable for the manual pulse generator
Cable for the MDI *3
RS-232C interface cable
Cable for the battery
Cable for the Ethernet
Other cables for which shield processing is
specified
Connect diodes with the DC solenoid and relay.
Bind the cables in group B separately from group A*1,
or cover group B cables with an electromagnetic
shield*2.
Separate group B as far from group C as possible.
It is desirable to apply I.1.6.3. Cable Clamp and Shield
Processing(P.50).
Bind the cables in group B separately from group A*1,
or cover group B cables with an electromagnetic
shield*2.
Separate group C as far from group B as possible.
Be sure to perform shield processing.
Be sure to perform shield processing.
See I.1.6.3. Cable Clamp and Shield Processing(P.50) for
details.
*1: Bind each group of cables separately and 10 cm or more apart from one another.
*2
: Provide shielding between groups with grounded steel plates.
*3: It is not necessary to shield the cable for the MDI.
Do not coil up extra cable.
If it is coiled, there is a risk that inductance may increase and a very high voltage may be induced when signals turn
ON/OFF, possibly leading to equipment failure or a malfunction due to noise.
NOTE
Select cables with an appropriate length.
If cables are longer than necessary, noise immunity may be reduced or noise may be induced on other cables.
47
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.6.1-1 Cable layout example
Part
Name
[A]
24V DC power supply
[B]
Spindle amplifier
[C]
Servo amplifier
[D]
I/O unit
[E]
Control unit
[F]
AC voltage input device
*1: Be sure to insert a shielding plate.
1.6.2.
Surge Absorber
Actuators, such as solenoids and relays, used in control cabinets need a surge absorber.
Because an actuator, which converts electrical energy to mechanical action, is an inductive load, it resonates
intermittently with parasitic capacitance of a circuit, and intermittent arcs accompanied by rapid voltage rises and falls
are generated at contacts. This generates electromagnetic waves and leads to disturbance of the electronic circuit.
As a remediation measure, treat the inductive load as described below.
• Referring to the treatment of cable groups A and B described in " I.1.6.1. Separating Cables(P.46)", use a CR
snubber circuit for the inductive load of an AC circuit or a diode for that of a DC circuit.
• Refer to the following when selecting them.
Cautions for selecting and using a CR snubber
• Use a CR snubber for an AC circuit.
A varistor, which is a voltage clamping element, can limit the peak of an oscillating voltage waveform but cannot
ease sharp voltage transitions. For this reason, FANUC recommends using a CR snubber.
• Determine the specifications of the resistor and capacitor in the CR snubber based on the steady-state current I
(A) and DC resistance RL (Ω) of the inductive load as follows:
48
B-64805EN/03
Control unit and lcd unit hardware
• Place the CR snubber close to the inductive load, and minimize the length of its wiring.
Fig. 1.6.2-1 Example of applying a CR snubber
Part
Name
[A]
Inductive load (relay, etc.)
[B]
CR snubber
[C]
General purpose induction motor
Cautions for selecting and using a diode
• A diode (freewheeling diode) can be used as a surge absorber for a DC driver circuit.
• The ratings of the diode must meet the following conditions for the drive voltage and current for the inductive load
(solenoid coil, relay, motor):
•
Voltage rating: Approximately twice the voltage applied to the inductive load
•
Current rating: Approximately twice the steady-state current flowing through the inductive load
• Place the diode close to both ends of the inductive load, and minimize the length of its wiring.
49
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.6.2-2 Example of applying a diode
Part
Name
[A]
Diode
[B]
Inductive load (relay, etc.)
1.6.3.
Cable Clamp and Shield Processing
If cables that are fed into the control unit, servo amplifier, spindle amplifier, or the like need shielding (as for signal
lines, they basically need shielding) to suppress the impact of external noise, clamp all these cables in the way shown
in Fig. 1.6.3-1.
This clamping type works for both cable support and shielding. Be sure to perform clamping because it is essential for
stable system operation. Clamping shields correctly can suppress the impact of external noise.
Partially peel the sheath off a cable and expose the outside of the shield, and use the clamp to press the exposed
portion against the ground bar for cable clamping.
This causes the outside of the shield and the ground bar to have surface contact. Make adjustments such that the
area of contact is as large as possible.
When the multipoint grounding scheme is used, care should be taken so that the ground bar for the shield clamp and
cabinet are connected with low impedance by, for example, preventing the cabinet side contact surface from being
coated.
When using an in-line connector or the like to split a cable, it is necessary to connect the shield of one portion of the
cable and that of the other portion and to keep the total impedance of the two cable portions from becoming high.
Even if the connector is placed at the inlet of the cabinet, it is also necessary to use the shield for the intra-cabinet
portion of the cable all the way to the other end of the cable.
50
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.6.3-1 Cable clamp
Part
Name
[A]
Ground bar for cable clamping
[B]
Cable
[C]
Outside of shield
[D]
Metal fitting for clamp
Do not coil up extra cable.
If it is coiled, inductance increases and a very high voltage is induced when signals turn ON/OFF, possibly leading to
breakdown or a malfunction due to noise.
NOTE
Select cables with an appropriate length.
If cables are longer than necessary, noise immunity may be reduced or noise may be induced on other cables.
Clamp the outside of shields of cables that feed into the control unit or amplifier at points close to their respective
units.
The machine-tool builder is requested to make a ground bar for cable clamping. It should be shaped like the one
shown in Fig. 1.6.3-2.
The ground bar for cable clamping must be made of a steel plate at least 2 mm thick and plated with nickel.
Further, provide cabinet mounting screw holes, clamp metal fitting mounting holes, and a ground terminal.
51
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.6.3-2 Ground bar for cable clamping (outline drawing)
Part
Name
[A]
Ground bar for cable clamping
[B]
Ground terminal grounding hole
[C]
Clamp metal fitting mounting hole
[D]
Ground bar mounting screw holes
If using a FANUC clamp metal fitting, the clamp metal fitting mounting hole dimensions and hole spacing should be
like those in Fig. 1.6.3-3
Fig. 1.6.3-3 Ground bar for cable clamping: Making mounting holes for clamp metal fitting
Part
[A]
Name
Ground bar for cable clamping
Fig. 1.6.3-4 is an outline drawing (for reference) of FANUC's clamp metal fitting.
52
B-64805EN/03
Control unit and lcd unit hardware
Fig. 1.6.3-4 Outline drawing of clamp metal fitting
Order the FANUC clamp metal fitting using the following order specification:
• Order specification: A02B-0303-K001 (Clamp metal fitting x 8 pieces)
Install the ground bar for cable clamping on the cabinet as shown in Fig. 1.6.3-5.
Fig. 1.6.3-5 shows a cross-section of the ground bar for cable clamping installed on the cabinet with a control unit
cable clamped, as seen from the side of the cabinet.
53
Control unit and lcd unit hardware
B-64805EN/03
Fig. 1.6.3-5 Connection diagram for the cabinet and the ground bar for cable clamping
Part
Name
[A]
Cabinet
[B]
Ground bar for cable clamping
[C]
Contacting surfaces of cabinet and ground bar for cable clamping (the portion where the cabinet coating is
removed)
Cabinet coating
[D]
1.6.4.
Lightning Surge Absorber Installation
Installing a surge protector between the AC input power supply lines and between input power supply and the
grounds is effective for protecting equipment from lightning-caused voltage surges.
However, installing a surge absorber does not always ensure protection from lightning surges.
For lightning surge protector specifications and wiring examples, see "SERVO AMPLIFIER αi-D series
DESCRIPTIONS" (B-65552EN).
Connect the 24V DC power supply for the control unit to the same location as the 24V DC power supply for the servo
amplifier.
54
B-64805EN/03
2.
LCD unit interfaces
LCD unit interfaces
This chapter describes the LCD unit interfaces (SD card and USB).
2.1.
SD Card
The SD card slot is compatible with SDHC standard SD cards.
SD cards that are guaranteed to work with the SD card slot of the LCD unit can be purchased from FANUC. When
SD cards that have not been guaranteed to work are used, they may not work properly.
A list of recommended SD cards is shown in Table 2.1-1.
Table 2.1-1 Recommended SD card list
Ordering specification
Capacity
A02B-0370-K210 (parts specification: A87L-00010230#001GB)
A02B-0370-K211 (parts specification: A87L-00010230#002GB)
A02B-0370-K212 (parts specification: A87L-00010230#004GB)
A02B-0370-K213 (parts specification: A87L-00010230#016GB)
Format
1 GB
FAT16
2 GB
FAT16
4 GB
FAT32
16 GB
FAT32
Fig. 2.1-1 SD card slot of the LCD unit
Part
Name
[A]
LCD unit
[B]
SD card slot
Do not remove the SD card or turn off the unit power while accessing the SD card.
There is a risk of corruption or loss of data on the SD card.
In order to prevent the SD card slot from being damaged due to dust and coolant, close the SD card slot lid except
when the SD card is inserted or removed.
55
LCD unit interfaces
B-64805EN/03
NOTE
SD cards purchased from third parties are not guaranteed to work with the SD card slot.
SD cards must be initialized with quick formatting before use.
When inserting an SD card, check that the write-protect switch on the SD card is set as intended.
China RoHS for recommended SD cards
2.2.
USB
This section describes the connection between the LCD unit and USB devices.
The location of the USB port on the LCD unit is shown in Fig. 2.2-1.
56
B-64805EN/03
LCD unit interfaces
Fig. 2.2-1 USB port of the LCD unit
Part
Name
[A]
LCD unit
[B]
USB port (USB 3.0-compatible)
Do not turn the control unit off or remove USB devices while accessing USB devices. That may damage the USB
devices and data.
In order to prevent the USB port from being damaged by dust and coolant, etc., close the USB port lid except
when the USB port is in use.
The USB port is not designed to be used for long periods of time with the lid open. Use of the USB port should be
temporary.
NOTE
Do not connect USB devices that exceed the supply current of their USB ports, as this will damage USB ports.
The maximum supply current of the USB 3.0 standard is 900mA.
When using a USB device that requires a higher current than the supply current of the USB port, prepare a
separate power supply.
It is not guaranteed that every commercially available USB devices can operate normally.
A USB memory with a security function does not operate. In addition, some commercially available USB memories
may not be designed for use in an FA environment.
The maximum USB cable length is 5 m for USB2.0/1.1 and 3 m for USB3.0. Repeaters can be used to extend the
cable, but must be thoroughly verified.
57
II Display and operation of screens
B-64805EN/03
1.
Menu Screen, Function Keys, and Soft Keys
Menu Screen, Function Keys, and Soft Keys
This section describes operations of the menu screen, function keys, and soft keys.
1.1.
General Screen Operations
1. Switch to the desired application by pressing the menu screen and function keys.
2. Select the screen of the operation that you want to perform using the soft keys (vertical soft keys) on the right side
of the screen.
1.2.
Menu Screen
In the menu screen, various applications categorized into setup and machining, utilities, and maintenance can be
launched. In addition to preregistered applications, you can register applications specific for machine-tool builders to
the Menu screen. You can quickly switch between each application from the menu screen in which the work of this
machining site is consolidated.
Fig. 1.2-1 Menu Screen
Launch an application in the following way:
• Operation with MDI unit: Use the <←> <→> <↑> <↓> keys to select an icon and press the <INPUT> key.
• Operation with touch panel: Tap the icon of the application that you want to launch.
Press the <MENU> key to switch from other applications to the menu screen.
61
Menu Screen, Function Keys, and Soft Keys
B-64805EN/03
Fig. 1.2-2 MDI unit (QWERTY keyboard)
The following applications are pre-registered on the menu screen.
Table 1.2-1 Application list
Application name
Functional overview
Operation
Set-up & Machining
Allows you to set up and execute programs in the CNC
screen.
Program Manager
Allows you to manage program files in the CNC screen.
Edit Program
Allows you to edit programs in the CNC screen.
TOOL
Allows you to set the tool compensation amount in the CNC
screen.
Work
Allows you to set the workpiece coordinate system in the
CNC screen.
Screen
Utilities
Allows you to configure settings related to the display unit
and the whole system.
Data I/O
Allows you to input and output CNC data.
PMC
Maintenance
Allows you to check the PMC program execution state and
signal status.
NETWORK
62
Allows you to configure the network settings for the CNC
and display units.
Icon
B-64805EN/03
Menu Screen, Function Keys, and Soft Keys
Application name
Functional overview
Settings & Diagnosis
Allows you to configure CNC settings and check the status.
DCS
Allows you to check the CNC status related to DCS (Dual
Check Safety).
Power Consumption Monitor
Allows you to monitor and configure the power
consumption.
History
Allow you to view the history of messages and operations
that have occurred.
Icon
NOTE
Some preparation, such as data registration or settings, is required depending on the application.
Due to configurations by the machine-tool builder, some applications may not appear, or manufacturer-specific
applications may be added.
1.3.
Function Keys
Function keys are provided to select the type of screen to be displayed.
The following function keys are provided on the MDI unit:
Loca
tion
Name
Displayed information
Left 1
Function key <Operation>
Switches to the operation screen.
Left 2
Function key <Program>
Switches to the screen included in the program category.
Left 3
Function key <Setup>
Switches to the screen included in the setup category.
Left 4
Function key <MESSAGE>
Switches to the message screen.
Left 5
Function key <APP1>
Switches to the specified screen.
Left 6
Function key <APP2>
Switches to the specified screen.
Left 7
Function key <SYSTEM>
Switches to the screen for the machine-tool builder.
1.4.
Soft keys
Soft keys are located on the right side and bottom of the screen. These soft keys can be used to perform most
operations.
Select the screen of the operation that you want to perform using the soft keys (vertical soft keys) on the right side of
the screen.
63
Menu Screen, Function Keys, and Soft Keys
B-64805EN/03
The soft keys at the bottom of the screen (horizontal soft keys) are used to perform operations on the currently
displayed screen.
Fig. 1.4-1 Soft key placement
64
B-64805EN/03
2.
System configuration screen
System configuration screen
You can check the type of installed printed circuit board, software type, and motor information.
2.1.
Displaying System Configuration Screen
The system configuration screen can be displayed in the following ways:
Display the Settings & Diagnosis screen by either of the following methods:
•
Press the <SYSTEM> key
•
Press the [Settings & Diagnosis] icon on the menu screen
A list of the Settings & Diagnosis screens is displayed.
If an application other than the screen list appears, press the [Screen List] key or the <SYSTEM>
key.
Select the "SYSTEM CONFIGURATION" icon in the screen list
The system configuration screen is displayed.
65
System configuration screen
66
B-64805EN/03
B-64805EN/03
2.2.
System configuration screen
Names and functions of each section of the System Configuration
Screen
Fig. 2.2-1 Names and functions of each section of the System Configuration screen
Table 2.2-1 Names and functions of each section of the System Configuration screen
Location
Control name
Description
A
Screen name display section
The screen name "SYSTEM CONFIGURATION" is displayed.
B
Category selection pane
System configuration-related categories are displayed in a tree format.
C
System display section
D
Detailed description display
section
Guidance message display
section
A list of system settings belonging to the category selected in the
category selection section is displayed.
Details of the item selected in the system display section are
displayed.
Guidance and warning messages are displayed in response to the
operation.
E
2.2.1.
Soft Keys on the System Configuration Screen
Vertical soft keys
The vertical soft key section displays soft keys for transitioning to other screens. Pressing each soft key switches to
the specified screen.
67
System configuration screen
B-64805EN/03
Display
conditio
ns
Conditions under
which pressing is
possible
Screen List
None
None
A list of screens for setting up and diagnosing
the CNC is displayed.
Message
None
None
The message screen is displayed.
Set-up & Machining
None
None
The Set-up & Machining screen is displayed.
Menu
None
None
The menu screen is displayed.
Soft keys
Icon
Operation when pressed
Horizontal soft keys
The horizontal soft keys display the soft keys for using the functions available in the screen.
68
B-64805EN/03
Soft keys
Reload
Reflect
Refresh
System configuration screen
Icon
Display
conditio
ns
Conditions under
which pressing is
possible
When
either of
the
following
screens
is
displaye
d
- Servo
informati
on
- Spindle
informati
on
None
And
when the
paramet
ers are
set as
follows
- Bit 1
(IDC) of
paramet
er No.
11320 is
set to 1
- Bit 0
(IDW) of
paramet
er No.
13112 is
set to 1
When
either of
the
following
screens
is
displaye
d
- Servo
informati
on
- Spindle
informati
on
And
when bit
0 (IDW)
of
paramet
er No.
13112 is
set to 1.
When
either of
the
following
screens
Operation when pressed
Reacquires the ID information for all axes that
is output from each of the connected units
displayed on the servo or spindle information
screen at a time.
The following behavior occurs depending on
the setting of bit 6 (IDU) of parameter No.
24311.
No.24311#6=0: ID information held by CNC is
deleted. ID information of connected motors is
reacquired when CNC is restarted.
No.24311#6=1: ID information held by CNC is
deleted, ID information of connected motors
are reacquired, and screen drawing is
updated.
None
Changed ID information is reflected in CNC in
a batch.
None
Changed, unreflected ID information is
reverted to the pre-modified values.
69
System configuration screen
Soft keys
Icon
Display
conditio
ns
B-64805EN/03
Conditions under
which pressing is
possible
Operation when pressed
is
displaye
d
- Servo
informati
on
- Spindle
informati
on
And
when bit
0 (IDW)
of
paramet
er No.
13112 is
set to 1.
2.2.2.
Information Displayed on the System Configuration Screen
The system configuration screen displays the following information.
Name
Display conditions
CNC ID information
System (hardware)
System (software)
None
None
None
PMC
None
MEXE
None
Servo Info
Bit 1 (SVI) of
parameters No.
13112 is set to 0
Bit 2 (SPI) of
parameter No. 13112
is set to 0
Additional information
supplied by the
machine-tool builder
exists
Peripheral equipment
process information
exists
Peripheral equipment
IDROM information
exists
Spindle Info
Machine information
Peripheral equipment process
information
Peripheral equipment IDROM
information
2.3.
Description
The unique ID information for each CNC can be viewed.
Hardware information can be viewed.
The CNC software series/version information can be
viewed.
The series/version number of sequence programs, I/O
Link i assignment data, and PMC message data can be
viewed.
Data related to the series/version number included in the
macro executor application data can be viewed.
Information on servo motors connected to the machine
can be managed and viewed.
Information on spindle motors connected to the machine
can be managed and viewed.
Additional information supplied by the machine-tool
builder, if any, can be viewed.
Information on peripheral equipment (Display unit) used
with the machine can be viewed.
The unique ID information for each peripheral equipment
(Display unit) used with the machine can be viewed.
Changing Servo and Spindle ID Information
Servo and spindle ID information is automatically read from each of the connected units during the first startup of the
CNC and then stored.
70
B-64805EN/03
System configuration screen
You can check whether the configuration of the connected units has been changed by comparing the ID information
stored during the first startup with the ID information that can be currently read.
(If the value stored on the FROM is different from the value read from the connected device, "*" is displayed at the
beginning of each item to indicate a warning.)
The servo and spindle ID information can be edited when the motor is replaced due to failure, for example.
To change the servo and spindle ID information, bit 0 (IDW) of parameter No. 13112 must be set to 1.
Input operations in each display are reflected in the CNC by pressing the [Reflect] key.
If you switch to another category without pressing the [Reflect] key, input operations are canceled.
71
Diagnosis screen
3.
B-64805EN/03
Diagnosis screen
CNC settings and status can be checked in the diagnosis screen.
3.1.
Displaying the Diagnosis Screen
The Diagnosis screen can be displayed by performing the following operations:
■When using the <SYSTEM> key
Press the <SYSTEM> key several times
The display switches in the order of Screen List -> Parameter Settings -> Diagnosis -> Screen List -> ...
■When using the screen list
Display the Settings & Diagnosis screen by either of the following methods:
• Press the <SYSTEM> key
• Press the [Settings & Diagnosis] icon on the menu screen
A list of the Settings & Diagnosis screens is displayed.
If a screen other than the screen list appears, press the [Screen List] key or the <SYSTEM> key.
Select the Diagnosis icon in the screen list
72
B-64805EN/03
Diagnosis screen
The diagnosis screen is displayed.
73
Diagnosis screen
3.2.
B-64805EN/03
Names and Functions of Each Section of the Diagnosis Screen
Fig. 3.2-1 Names and functions of each section of the diagnosis screen
Table 3.2-1 Names and functions of each section of the diagnosis screen
Location
Control name
Description
A
Screen name display section
The screen name "Diagnosis" is displayed.
B
Category selection section
Diagnosis data categories are displayed in a tree format.
C
Diagnosis data display section
D
Detailed description display section
A list of diagnosis data belonging to the selected category is
displayed.
Details on the selected diagnosis data are displayed.
3.2.1.
Soft Keys on the Diagnosis Screen
Vertical soft keys
The vertical soft keys in the diagnosis screen display soft keys for transitioning to other screens. Pressing each soft
key switches to the specified screen.
74
B-64805EN/03
Diagnosis screen
Display
conditio
ns
Conditions under
which pressing is
possible
Screen List
None
None
A list of screens for setting up and diagnosing
the CNC is displayed.
Message
None
None
The message screen is displayed.
Set-up & Machining
None
None
The Set-up & Machining screen is displayed.
Menu
None
None
The menu screen is displayed.
Soft keys
Icon
Operation when pressed
Horizontal soft keys
The horizontal soft keys display the soft keys for using the functions available in the screen.
Soft keys
Search
Icon
Display
conditio
ns
Conditions under
which pressing is
possible
None
None
Operation when pressed
The search window is displayed. In the search
window, diagnosis data can be searched for
by specifying the diagnosis number.
75
Diagnosis screen
B-64805EN/03
Display
conditio
ns
Conditions under
which pressing is
possible
Detail:up
None
None
Moves back to the previous description page.
Detail:down
None
None
Moves to the next description page.
Soft keys
3.2.2.
Icon
Operation when pressed
Information Displayed on the Diagnosis Screen
The diagnosis screen consists of the category selection section, diagnosis data display section, and diagnosis data
description section. The following information is displayed in these sections.
Category selection pane
A range of diagnosis data can be selected from a tree.
A list of diagnosis data belonging to the selected category is displayed in the diagnosis data display section.
Fig. 3.2.2-1 Names and functions of each part of the category selection section (1)
Table 3.2.2-1 Names and functions of each part of the category selection section (1)
Location
A
76
Name
Header
Description
The title "Diagnosis Number" will be displayed.
B-64805EN/03
Diagnosis screen
Location
Name
B
Node
C
Vertical scroll bar
Description
Category names are displayed. By selecting a node, the
diagnosis data for the specified range can be displayed in
the diagnosis data display section.
A vertical scroll bar appears when the data belonging to
the selected category does not fit within the display area.
Diagnosis data display section
The values of the diagnosis data selected in the category selection section are displayed.
By selecting diagnosis data, a description is displayed in the diagnosis data description section.
Fig. 3.2.2-2 Names and functions of each part of the diagnosis data display section (2)
Table 3.2.2-2 Names and functions of each part of the diagnosis data display section (2)
Location
Name
A
Header
B
Diagnosis number/axis
name
C
Diagnosis data
D
Symbol name
E
Vertical scroll bar
Description
The headers of the first column (diagnosis number), second column
(diagnosis data), third column (unit), and fourth column (symbol name) of the
diagnosis data display section are displayed.
This part is fixed regardless of the scrolling of the table.
The values of the diagnosis numbers are displayed in the form of "diagnosis
number - axis name".
Axis names appear only in the axis-type diagnosis data.
For a path with no controlled axis or spindle in the axis-type diagnosis data,
[-] is displayed and no axis name is displayed.
Values of diagnosis data are displayed.
For bit-type diagnosis data, 8 bits of the data are displayed per line.
In this case, the left-most side represents #7 and the right-most side
represents #0.
For non-bit-type diagnosis data, the entire data is displayed per line.
Unique symbol names for diagnostic numbers/bit values are displayed.
A vertical scroll bar appears when the diagnosis data belonging to the
selected category does not fit within the display area.
Detailed description display section
Details on the selected diagnosis data are displayed.
77
Diagnosis screen
3.3.
B-64805EN/03
Searching for Diagnosis Data
In the search window, diagnosis data can be searched for by specifying the diagnosis number(bit number).
3.3.1.
Displaying the Search Window
The search window can be displayed by performing the following operations:
Press the [Search] key on the diagnosis screen.
The search window is displayed.
78
B-64805EN/03
Diagnosis screen
79
Diagnosis screen
3.3.2.
B-64805EN/03
Names and Functions of Each Section of the Search Window
Fig. 3.3.2-1 Names and functions of each section of the search window
Table 3.3.2-1 Names and functions of each section of the search window
Location
80
Name
Description
A
Window title
The name of the function is displayed.
B
Description
C
Entry field
D
Guidance message
Descriptions on how to search for diagnosis data with and
without bits are displayed.
Enter the diagnosis number (bit number) to search for.
1. Exact match search
Diagnosis data exactly matching the entered value is
searched for.
For bit-type diagnosis data, enter the value that you want
to search for in the form of "diagnosis number#bit number".
For non-bit-type diagnosis data, enter the value that you
want to search for in the form of "diagnosis number".
2. Fuzzy search for bit-type diagnosis data
Bit-type diagnosis data is searched for based on the
diagnosis number only.
Enter the bit-type diagnosis number that you want to
search for in the form of "diagnosis number".
The focus moves to the location of the first bit number
matched.
3. Neighborhood search
The focus moves to the location of the next valid diagnosis
number when the diagnosis number entered for the above
methods 1 and 2 does not exist.
A message will be displayed in response to the operation in the
window.
B-64805EN/03
Diagnosis screen
Soft keys
The horizontal soft keys in the search window are as follows.
Fig. 3.3.2-2 Soft keys in the search window
Table 3.3.2-2 Soft keys in the search window
Soft keys
Display
conditions
Icon
Gray-out conditions
Operation when pressed
[Cancel]
None
None
Cancels the search operation.
[OK]
None
None
Diagnosis data can be searched
for by specifying the diagnosis
number (bit number).
3.3.3.
Searching by Diagnosis Number
You can search for a diagnosis number by following the steps below.
■Perform a search
Enter a diagnosis number.
Press the <INPUT> or [OK] key.
The diagnosis data specified in the window is searched for.
■Cancel the search
Press the [Cancel] key.
The search operation is canceled and the search window is closed.
■Warning message
Messages are displayed in the guidance message section of the search window.
Message
Format Error
Description/cause
A format error is found for the entered diagnosis number. Enter
the number in the form of "number#number" or "number".
81
CNC state display
4.
B-64805EN/03
CNC state display
CNC status is displayed in the status display section at the top of each application screen.
Fig. 4-1 Status display section
4.1.
Items Displayed in the Status Display Section
The status display area consists of the following display functions.
Fig. 4.1-1 Items in the status display section
4.1.1.
Viewing CNC Status
The following information is indicated with icons.
82
B-64805EN/03
CNC state display
Fig. 4.1.1-1 CNC status display icons
Table 4.1.1-1 CNC status display icons
Location
Name
A
Path being operated
Contents
Indicates the path currently being operated with an icon.
Displayed
icon
Status
A single path
being selected
Loader path
being selected
B
Operation Mode
Status
Description
MDI mode
Indicates that the current mode is the manual
data input (MDI operation) mode.
MEM mode
Indicates that the current mode is the
automatic operation (memory operation)
mode.
Indicates that the current mode is the memory
edit mode.
EDIT mode
Program operation
Indicates that the first path of a multi-path
system is being displayed/operated. (The
corresponding numeric icons are also
displayed for the second and subsequent
paths.)
Indicates that a loader path of a multi-path
system is being displayed/operated.
Indicates the current operation mode with an icon.
Displayed
icon
C
Description
Handle mode
Indicates that the current mode is the manual
handle feed mode.
JOG mode
Indicates that the current mode is the jog feed
mode.
TEACH IN
JOG mode
Indicates that the current mode is the teach-in
jog feed mode.
TEACH IN
HANDLE mode
Indicates that the current mode is the teach-in
handle feed mode.
Incremental
mode
Indicates that the current mode is the
incremental feed mode.
Reference
mode
Indicates that the current mode is the manual
reference position return mode.
Remote mode
Indicates that the current mode is the
automatic operation (DNC operation) mode.
Indicates the current program operation status with an icon.
Displayed
Status
Description
icon
Automatic
Indicates that the automatic operation is in
operation in
progress.
progress
Automatic
Indicates that one block has been executed
operation
and the automatic operation is stopped.
stopped
83
CNC state display
Location
Name
D
Emergency stop
state
E
Alarm information
display
F
B-64805EN/03
Axis stopped
Contents
Automatic
Indicates that one block has been aborted
operation
and the automatic operation is stopped.
aborted
Indicates an emergency stop state with an icon.
Displayed
Status
Description
icon
Emergency
Indicates an emergency stop state.
stop state
An alarm, operator message, or warning status is indicated with an icon.
Displayed
Status
Description
icon
Alarm status
Indicates that an alarm is generated for any of
the displayable paths.
An operator
An operator message or warning is present
message or
for any of the displayable paths.
warning
present
Indicates an axis stop state with an icon.
Displayed
icon
H
Offset value/shift
amount being written
Data being
input/output
Description
Axis stopped
Indicates that any of the diagnosis information
No. 0 is set to 1 and the operation is stopped
due to an axis stop.
Indicates that the current mode is the tool offset value write mode or the workpiece
coordinate shift amount write mode with an icon.
Displayed
icon
I
Status
Status
Offset
Indicates that direct input of tool offset value
value/shift
measured B is enabled and either the tool
amount being
offset value write mode or the workpiece
written
coordinate shift amount write mode is ON.
Indicates that data input/output is in progress with an icon.
Displayed
icon
Status
Data being
input/output
J
Input unit
Description
Indicates that data is being input/output. In
this state, do not turn off the CNC. If the
power is turned off while data is being
input/output, data may be corrupted.
Indicates the input unit with an icon.
Displayed
icon
4.1.2.
Description
Status
Description
Metric input
Indicates that the input unit is in metric.
Inch input
Indicates that the input unit is in inches.
Viewing Messages
NC alarm messages and operator messages for the displayed path can be viewed.
The message screen is displayed by touching a message whose message type is Alarm, Operator Message, or
Warning.
Messages displayed are classified with the following colors.
84
B-64805EN/03
CNC state display
Alarm type
Alarm
Operator message or warning
Reset notification or announcement
4.1.3.
Color
Background color: yellow
Text color: red
Background color: yellow
Text color: black
Background color: blue
Text color: white
Viewing User Information
User icons and user names are displayed.
Touching the user information calls the user switching function from the menu screen.
4.1.4.
Viewing the Time
The current time set on the display unit is displayed.
85
Maintenance information screen
5.
B-64805EN/03
Maintenance information screen
On the maintenance information screen, you can check maintenance-related information entered at the factory and
record maintenance works performed by FANUC and the machine-tool builder.
5.1.
Displaying the Maintenance Information Screen
The maintenance information screen can be displayed in the following ways:
Display the Settings & Diagnosis screen by either of the following methods:
•
Press the <SYSTEM> key
•
Press the [Settings & Diagnosis] icon on the menu screen
A list of the Settings & Diagnosis screens is displayed.
If a screen other than the screen list appears, press the [Screen List] key or the <SYSTEM> key.
Select the Maintenance Information icon in the screen list
The maintenance information screen is displayed.
86
B-64805EN/03
Maintenance information screen
87
Maintenance information screen
5.2.
B-64805EN/03
Names and Functions of Each Section of the Maintenance
Information Screen
Fig. 5.2-1 Names and functions of each section of the maintenance information screen
Table 5.2-1 Names and functions of each section of the maintenance information screen
Location
Control name
Description
A
Screen name display section
The name of the screen is displayed.
B
Maintenance Information section
Maintenance information-related descriptions are displayed.
C
Guidance message display
section
Messages about the system alarm history is displayed.
5.2.1.
Soft Keys on the Maintenance Information Screen
Vertical soft keys
The vertical soft key section displays soft keys for transitioning to other screens. Pressing each soft key switches to
the specified screen.
88
B-64805EN/03
Maintenance information screen
Display
conditio
ns
Conditions under
which pressing is
possible
Screen List
None
None
A list of screens for setting up and diagnosing
the CNC is displayed.
Message
None
None
The message screen is displayed.
Set-up & Machining
None
None
The Set-up & Machining screen is displayed.
Menu
None
None
The menu screen is displayed.
Soft keys
Icon
Operation when pressed
Horizontal soft keys
The horizontal soft keys display the soft keys for using the functions available in the screen.
89
Maintenance information screen
B-64805EN/03
Display
conditio
ns
Conditions under
which pressing is
possible
Delete All
No.3116
#7=1 and
No.3206
#1=0
None
Top
None
None
This is an operation to completely erase
maintenance information.
By pressing the soft key, a window appears to
confirm whether the operation can be
performed or not.
Note that the original state cannot be restored
unless there is an external backup.
Moves to the top.
Bottom
None
None
Moves to the end.
Reflect
No.3206
#1=0
None
Edited maintenance information is reflected in
the CNC.
Refresh
No.3206
#1=0
None
Edits are canceled and the content saved on
the CNC side is reacquired and displayed.
Soft keys
5.2.2.
Icon
Operation when pressed
Information Displayed on the Maintenance Information Screen
The value set in bit 1 of parameter No. 3206 determines whether information in the maintenance information screen
can be edited or not.
View mode
When bit 1 of parameter No. 3206 is set to 1, maintenance information is displayed in the view mode.
In the view mode, the display section can be operated with the cursor keys or touch operation to check stored
maintenance information.
If you want to make changes to maintenance information, you must operate in the edit mode.
90
B-64805EN/03
Location
A
Maintenance information screen
Name
Maintenance
information
Description
Stored maintenance information is displayed.
Maintenance information is broken every 50 characters per line or at the position
where a line feed is explicitly inserted.
Edit mode
When bit 1 of parameter No. 3206 is set to 0, maintenance information is displayed in the edit mode.
In the edit mode, you can edit maintenance information by moving the caret to the position where you want to enter
characters.
91
Maintenance information screen
Location
Name
Description
A
Maintenance
information
B
Free Space
(byte)
5.3.
B-64805EN/03
Stored maintenance information is displayed.
You can insert alphanumeric characters or line feeds by moving the caret to the desired
position and pressing input keys.
When maintenance information is edited, it is in a temporarily saved state, so the edited
content is not retained when the CNC power is restarted. If you want to save changes,
press the [Reflect] key to reflect the changes in the CNC.
The number of bytes that can be entered is displayed.
The free space increases or decreases each time a character or line feed is entered.
Parameters
The maintenance information screen is associated with the following parameters.
3116 #7
MDC
[Input type]
[Data type]
Setting input
Bit path
Clearing maintenance information data is:
0: Not allowed.
1: Allowed.
3206 #1
92
MIF
B-64805EN/03
[Input type]
[Data type]
Maintenance information screen
Parameter input
Bit
Editing of the maintenance information screen is:
0: Not prohibited.
1: Prohibited.
8901 #7
MEN
[Input type]
[Data type]
Setting input
Bit path
The periodic maintenance screen and the maintenance information screen is:
0: Performed
1: Not performed
93
FSSB connection status screen
6.
B-64805EN/03
FSSB connection status screen
In the FSSB connection status screen, the connection state of the slave unit in the FSSB line can be easily checked.
When an FSSB communication error occurs, the unit where the problem occurs is displayed in red so that it can be
easily diagnosed.
6.1.
Displaying the FSSB connection status Screen
The FSSB connection status screen can be displayed in the following ways:
Display the Settings & Diagnosis screen by either of the following methods:
•
Press the <SYSTEM> key
•
Press the [Settings & Diagnosis] icon on the menu screen
A list of the Settings & Diagnosis screens is displayed.
If a screen other than the screen list appears, press the [Screen List] key or the <SYSTEM> key.
Select the FSSB Connection State icon in the screen list
The FSSB connection status screen is displayed.
94
B-64805EN/03
FSSB connection status screen
95
FSSB connection status screen
6.2.
B-64805EN/03
Names and Functions of Each Section of the FSSB connection
status Screen
Fig. 6.2-1 Names and functions of each section of the FSSB connection status screen
Table 6.2-1 Names and functions of each section of the FSSB connection status screen
Location
Control name
Description
A
Screen name display section
The name of the screen is displayed.
B
Connection state display section
C
Message display section
D
Guidance message display
section
The current connection state for each FSSB line is displayed in a tree
format.
The connection state of up to two lines is displayed in one screen.
The status of the spindle motor selected in the category selection
section is displayed.
Messages about the system alarm history is displayed.
6.2.1.
Soft Keys on the FSSB connection status screen
Vertical soft keys
The vertical soft key section displays soft keys for transitioning to other screens. Pressing each soft key switches to
the specified screen.
96
B-64805EN/03
FSSB connection status screen
Display
conditio
ns
Conditions under
which pressing is
possible
Screen List
None
None
A list of screens for setting up and diagnosing
the CNC is displayed.
Message
None
None
The message screen is displayed.
Set-up & Machining
None
None
The Set-up & Machining screen is displayed.
Menu
None
None
The menu screen is displayed.
Soft keys
Icon
Operation when pressed
Horizontal soft keys
The horizontal soft keys display the soft keys for using the functions available in the screen.
97
FSSB connection status screen
B-64805EN/03
Display
conditio
ns
Conditions under
which pressing is
possible
Status
None
- When a status other
than the connection
state is displayed
Alarm
None
- When a status other
than the alarm status
is displayed
System Alarm 1
At least
one
system
alarm
history
exists
At least
two
system
alarm
histories
exist
At least
three
system
alarm
histories
exist
At least
four
system
alarm
histories
exist
At least
five
system
alarm
histories
exist
When an alarm other
than the system
alarm 1 is displayed
Soft keys
System Alarm 2
System Alarm 3
System Alarm 4
System Alarm 5
6.2.2.
Icon
Operation when pressed
The current connection state is displayed.
When a connection error occurs, the node
where the error occurs is displayed in red.
When there is no connection error, a
message indicating that the FSSB connection
state is normal is displayed in the guidance
message display section.
When an alarm related to FSSB is currently
occurring, the FSSB connection state that has
been successfully started up in the past is
compared with the current FSSB connection
state, and the node with a difference is
displayed in red.
When there is currently no alarm related to
FSSB, a message indicating that no FSSB
communication error alarm has occurred is
displayed in the guidance message display
section.
The problematic area that caused the last
FSSB-related system alarm is displayed in
red.
A comment about the system alarm is
displayed in the message display section.
When an alarm other
than the system
alarm 2 is displayed
The problematic area that caused the second
last FSSB-related system alarm is displayed
in red.
Other operations are the same as for the
[System alarm 1] key.
When an alarm other
than the system
alarm 3 is displayed
The problematic area that caused the third
last FSSB-related system alarm is displayed
in red.
Other operations are the same as for the
[System alarm 1] key.
When an alarm other
than the system
alarm 4 is displayed
The problematic area that caused the fourth
last FSSB-related system alarm is displayed
in red.
Other operations are the same as for the
[System alarm 1] key.
When an alarm other
than the system
alarm 5 is displayed
The problematic area that caused the fifth last
FSSB-related system alarm is displayed in
red.
Other operations are the same as for the
[System alarm 1] key.
Information Displayed on the FSSB connection status screen
The FSSB connection status screen consists of the connection state display section and the message display
section. The following information is displayed in these sections.
Connection state display section
The current connection state for each FSSB line is displayed in a tree format with up to two lines shown in one
screen.
Each node in the tree is connected by a ruled line, indicating the connection state of the FSSB.
98
B-64805EN/03
Name
A
Header
B
Tree expanded/collapsed
icon
Node
Status
C
D
FSSB connection status screen
Contents
The header "FSSBx (status)" is displayed.
x represents the FSSB line number.
The status in parentheses shows "normal" or "abnormal" according to the current
status.
If an FSSB communication error has occurred, it is displayed in red.
Indicates whether the tree is expanded or collapsed. The tree expanded/collapsed
icon appears for a node with child elements.
The type and name of the connected device is displayed.
The order of slave units connected to the FSSB line is indicated.
■Nodes
The connection state information that can be checked on the FSSB connection status screen is as follows.
99
FSSB connection status screen
Displayed node
A
FSSB
Example:
FSSB1(HRV3)
B
Servo amplifier
Example: SV(A1
L/M/N) (PS1 control
axis)
C
Controlled axis
Example: (L)1-01
"X1"
D
I/F Unit
Example:
SDU(Unit1)
Connector
Example: Connector
1(X1)
Spindle amplifier
Example: SP(B1)
E
F
G
100
Spindle
B-64805EN/03
Contents
Indicates the type and HRV value of the FSSB line.
There are two types of FSSB lines, FSSB1 and FSSB2, and either of the names will be
displayed.
There are three HRV values ranging from 2 to 4.
Displays servo amplifier information.
The number following the letter A indicates the placing of the servo amplifier, as counted
from that nearest to the CNC.
After that, "L/M/N" is displayed for 3-axis amplifiers, "L/M" for 2-axis amplifiers, or "L" for 1axis amplifiers.
For amplifiers connected to the PS (power supply), "(PSx control axis)" is displayed. x
represents the PS number.
Information on a controlled axis connected to the servo amplifier is displayed.
"(L)" is displayed for the first axis, "(M)" for the second axis of 2-axis and 3-axis amplifiers,
or "(N)" for third axis of 3-axis amplifiers.
After that, the line number and slave number connected with a hyphen and the name of the
connected axis are displayed with up to three characters (if axis name expansion is
enabled).
I/F Unit information is displayed.
The number following "Unit" indicates the placing of the amplifier, as counted from that
nearest to the CNC.
The connector number and corresponding axis name are displayed.
If there is no corresponding axis, "No connection" is displayed.
Servo amplifier information is displayed.
The number following the letter B indicates the placing of the spindle amplifier, as counted
from that nearest to the CNC.
For amplifiers connected to the PS (power supply), "(PSx control axis)" is displayed. x
represents the PS number.
Information on the spindle connected to the spindle amplifier is displayed.
B-64805EN/03
FSSB connection status screen
Displayed node
Example: (1)1-05
"S1"
Contents
After (1), the line number and slave number connected with a hyphen and the name of the
connected spindle are displayed with up to three characters (if spindle name expansion is
enabled).
■Checking the FSSB connection state
In the FSSB connection status screen, slave units and connectors that have established FSSB communication are
displayed in blue and those that have not established FSSB communication due to error are displayed in red.
In the wiring diagram displayed in the connection state display section, the current connection state, current alarm
status, and previous system alarm status can be checked by pressing the corresponding soft keys.
This screen can easily check the part where the problem with FSSB occurs. There is the following kind of FSSB
communication error diagnosis displays.
Contents displayed
1
2
3
Current FSSB connection state
Current FSSB-related alarm
Previous FSSB-related system alarms
Corresponding soft keys
[Status]
[Alarm]
[System alarm 1]
[System alarm 2]
[System alarm 3]
[System alarm 4]
[System alarm 5]
The current FSSB-related alarm and previous FSSB-related system alarms can be displayed only when FSSB
settings have been configured successfully at least once in the past.
Status
Current display shows the FSSB connection state.
Alarm display
Use the alarm display section to diagnose current FSSB alarms.
The state of the FSSB connection that was normally established in the past is compare with the current FSSB
connection. And, the different part is displayed in red. It is displayed by pressing the [Alarm] key.
System alarm history
Use the system alarm history 1 to 5 sections to diagnose previous FSSB alarms.
System Alarm History 1 Display shows the latest alarm log. System Alarm History 2 Display shows the alarm log that
occurred before the latest one.
In the display section for system alarm history 1 to 5 display, the state of the FSSB connection that was normally
established in the past and
the problematic area is displayed in red based on the system alarm history information.
This section can be displayed by pressing the soft keys [SYSA HISTORY1] to [SYSA HISTORY5].
101
FSSB connection status screen
B-64805EN/03
Message display pane
Displays a message about the system alarm history that occurred in the past when a system alarm history is
displayed.
Location
A
102
Contents
The first line displays the date and time of the system alarm in the format of YYYYY/MM/DD HH:MM:SS.
The second line displays a message about the system alarm.
B-64805EN/03
7.
Maintenance Monitor Screen
Maintenance Monitor Screen
In the maintenance monitor screen, FAN abnormalities and insulation deterioration can be easily checked.
7.1.
Displaying the Maintenance Monitor Screen
The maintenance monitor screen can be displayed in the following ways:
Display the Settings & Diagnosis screen by either of the following methods:
•
Press the <SYSTEM> key
•
Press the [Settings & Diagnosis] icon on the menu screen
A list of the Settings & Diagnosis screens is displayed.
If a screen other than the screen list appears, press the [Screen List] key or the <SYSTEM> key.
Select the Maintenance Monitor icon in the screen list
The Maintenance Monitor screen is displayed.
103
Maintenance Monitor Screen
104
B-64805EN/03
B-64805EN/03
7.2.
Maintenance Monitor Screen
Names and Functions of Each Section of the Maintenance Monitor
Screen
Fig. 7.2-1 Names and functions of each section of the maintenance monitor screen
Table 7.2-1 Names and functions of each section of the maintenance monitor screen
Location
Control name
Description
A
Screen name display section
The screen name "Maintenance Monitor" is displayed.
B
CNC and PS status display
section
FSSB status display section
Displays the fan status of the CNC and power supply.
C
D
E
F
Displayed icon description
section
Status description display section
Guidance message display
section
Displays the fan status of the amplifier connected to the FSSB line.
The FSSB line status of up to two lines is displayed in one screen.
A legend of the icons is shown.
Displays a text describing the current status.
Guidance, warning, and informational messages are displayed in
response to the operation.
105
Maintenance Monitor Screen
7.2.1.
B-64805EN/03
Soft Keys on the Maintenance Monitor Screen
Vertical soft keys
The vertical soft key section displays soft keys for transitioning to other screens. Pressing each soft key switches to
the specified screen.
Display
conditio
ns
Conditions under
which pressing is
possible
Screen List
None
None
A list of screens for setting up and diagnosing
the CNC is displayed.
Message
None
None
The message screen is displayed.
Set-up & Machining
None
None
The Set-up & Machining screen is displayed.
Menu
None
None
The menu screen is displayed.
Soft keys
Icon
Operation when pressed
Horizontal soft keys
The horizontal soft keys display the soft keys for using the functions available in the screen.
106
B-64805EN/03
Maintenance Monitor Screen
(When the node "PS" is selected)
(When the node "connector" is selected)
Display
conditio
ns
Conditions under
which pressing is
possible
Jump to Error
Abnorma
lity has
occurred
None
The cursor moves to the node where the
abnormality has occurred.
PS Control
The
node
"PS" is
selected
The
node
"connect
or" is
selected
None
The cursor moves to the axis connected to PS
(power supply).
None
The cursor moves to the axis connected to I/F
Unit.
Soft keys
Connection Axis
7.2.2.
Icon
Operation when pressed
Information Displayed on the Maintenance Monitor Screen
The maintenance monitor screen consists of the CNC and PS status display section, FSSB connection status display
section, displayed icon description section, status description display section, and guidance message display section.
The following information is displayed in these sections.
CNC and PS status display section
The status of CNC and PS (power supply) is indicated in a tree format.
By selecting an item, a relevant description is displayed in the status description section.
107
Maintenance Monitor Screen
Locatio
n
Name
(A)
Header
(B)
Node
B-64805EN/03
Description
The header "CNC,PS(status)" is displayed.
The status in parentheses shows "normal" or "abnormal" according to the current status.
If a fan abnormality has occurred, it is displayed in yellow.
Displays the names of the items that can be viewed in the CNC and PS status display section.
Display item
CNC
PSn
Example: PS1
Description
Displays CNC information.
When a fan abnormality has occurred, an
icon appears after the category name.
Displays PS (power supply) information.
n represents the amplifier group number.
When a fan abnormality has occurred, an
icon appears after the category name.
If an abnormality has occurred, the node with the abnormality is displayed in yellow and an icon
indicating an abnormality is displayed.
Icon
Meaning
Replacement required
108
Description
Indicates that the fan of the
item corresponding to the
node with the icon is in need
of replacement.
B-64805EN/03
Locatio
n
Maintenance Monitor Screen
Name
Description
Insulation deterioration
Measurement failed
Not supported
Not measured
Indicates that the insulation
of the item corresponding to
the node with the icon is
deteriorated.
Indicates that the status
measurement of the item
corresponding to the node
with the icon has failed.
Indicates that the item
corresponding to the node
with the icon is not
supported for status
measurement.
Indicates that the
measurement of the item
corresponding to the node
with the icon is not yet
performed.
When no icon is displayed, no abnormality has occurred.
When an icon is displayed, a fan abnormality has occurred or the insulation has deteriorated.
Select a node and check the message in the status description display section.
FSSB status display section
The current connection state for each FSSB line is displayed in a tree format with up to two lines shown in one
screen.
By selecting an item, a relevant description is displayed in the status description section.
109
Maintenance Monitor Screen
Locatio
n
Name
A
Header
B
Node
B-64805EN/03
Description
The header "FSSBx (status)" is displayed.
x represents the FSSB line number.
The status in parentheses shows "normal" or "abnormal" according to the current status.
If a fan abnormality has occurred, it is displayed in yellow.
Displays the names of the items that can be viewed in the FSSB status display section.
Display item
FSSB
Example: FSSB1(HRV3)
Servo amplifier
Example: SV(A1 L/M/N) (PS1 control axis)
Description
Indicates the type and HRV value of the
FSSB line.
There are two types of FSSB lines, FSSB1
and FSSB2, and either of the names will be
displayed.
There are three HRV values ranging from 2
to 4.
Displays servo amplifier information.
The number following the letter A indicates
the placing of the servo amplifier, as
counted from that nearest to the CNC.
After that, "L/M/N" is displayed for 3-axis
amplifiers, "L/M" for 2-axis amplifiers, or "L"
for 1-axis amplifiers.
For amplifiers connected to the PS (power
supply), "(PSx control axis)" is displayed. x
represents the PS number.
A fan abnormality is indicated with an icon.
110
B-64805EN/03
Locatio
n
Maintenance Monitor Screen
Name
Description
Controlled axis
Example: (L)1-01 "X1"
I/F Unit
Example: SDU(Unit1)
Connector
Example: Connector 1(X1)
Spindle amplifier
Example: SP(B1)
Spindle
Example: (1)1-05 "S1"
Information on a controlled axis connected
to the servo amplifier is displayed.
"(L)" is displayed for the first axis, "(M)" for
the second axis of 2-axis and 3-axis
amplifiers, or "(N)" for third axis of 3-axis
amplifiers.
After that, the line number and slave number
connected with a hyphen and the name of
the connected axis are displayed with up to
three characters (if axis name expansion is
enabled).
Insulation deterioration information, if any, is
indicated with an icon.
I/F Unit information is displayed.
The number following "Unit" indicates the
placing of the amplifier, as counted from that
nearest to the CNC.
The connector number and corresponding
axis name are displayed.
If there is no corresponding axis, "No
connection" is displayed.
Servo amplifier information is displayed.
The number following the letter B indicates
the placing of the spindle amplifier, as
counted from that nearest to the CNC.
Fan abnormality or insulation deterioration
information, if any, is indicated with an icon.
Information on the spindle connected to the
spindle amplifier is displayed.
After (1), the line number and slave number
connected with a hyphen and the name of
the connected spindle are displayed with up
to three characters (if spindle name
expansion is enabled).
Insulation deterioration information, if any, is
indicated with an icon.
If an abnormality has occurred, the node with the abnormality is displayed in yellow and an icon
indicating an abnormality is displayed.
The icons are the same as those shown in the CNC and PS status display sections.
When no icon is displayed, no abnormality has occurred.
When an icon is displayed, a fan abnormality has occurred or the insulation has deteriorated.
Select a node and check the message in the status description display section.
Icon
Meaning
Replacement required
Insulation deterioration
Measurement failed
Description
Indicates that the fan of the
item corresponding to the
node with the icon is in need
of replacement.
Indicates that the insulation
of the item corresponding to
the node with the icon is
deteriorated.
Indicates that the status
measurement of the item
111
Maintenance Monitor Screen
Locatio
n
Name
B-64805EN/03
Description
corresponding to the node
with the icon has failed.
Indicates that the item
corresponding to the node
with the icon is not
supported for status
measurement.
Indicates that the
measurement of the item
corresponding to the node
with the icon is not yet
performed.
Not supported
Not measured
C
Status
The order of slave units connected to the FSSB line is indicated.
Displayed icon description section
The legend and descriptions of the icons that appear on the maintenance monitor screen are displayed.
Icon
112
Meaning
Description
Replacement
required
Indicates that the fan of the item corresponding to the node with the icon is in need of
replacement.
Insulation
deterioration
Indicates that the insulation of the item corresponding to the node with the icon is
deteriorated.
Measurement failed
Indicates that the status measurement of the item corresponding to the node with the
icon has failed.
B-64805EN/03
Icon
Maintenance Monitor Screen
Meaning
Description
Not supported
Indicates that the item corresponding to the node with the icon is not supported for
status measurement.
Not measured
Indicates that the measurement of the item corresponding to the node with the icon is
not yet performed.
Status description display section
The slave unit associated with the selected node and slave status messages are displayed in the status description
display section.
Status
Operation
In the normal state
When a fan error has occurred
Select the following nodes where an
abnormality has occurred
CNC
PS (power supply)
When a fan error has occurred
Select the following nodes where an
abnormality has occurred
Servo amplifier
Spindle amplifier
Message
Nothing is displayed.
A fan abnormality has occurred.
FAN1: (*2)
FAN2: (*2)
FAN3: (*2)
FAN4: (*2)
Displayed as blank if there is no fan.
A fan abnormality has occurred.
Internal FAN1: (*2)
Internal FAN2: (*2)
FIN FAN1: (*2)
FIN FAN2: (*2)
Displayed as blank if there is no fan
or heat sink.
113
Maintenance Monitor Screen
Status
When insulation deterioration
has occurred
When measurement is not yet
performed
B-64805EN/03
Operation
Message
Select the following nodes where an
abnormality has occurred
Servo amplifier
Spindle amplifier
Axis
One of the following will be
displayed:
Select the node where measurement has
not been performed
Axis
Leakage has occurred.
It does not support the leakage
function.
Leakage resistance value has not
been measured.
Failed to measure.
Leakage resistance value has not
been measured.
(*1) The name of the amplifier is displayed.
(*2) Descriptions and status displayed are as follows.
When the selected node is CNC
Status
In the normal state
Abnormal rotation speed (replacement required 1)
Fan sticking (replacement required 2)
Abnormal rotation speed and fan sticking
Message
No errors are detected.
The speed of the fan decreased.
The boot error is detected.
The boot error is detected.
When the selected node is PS (power supply), servo amplifier, or spindle amplifier
Status
In the normal state
Abnormal rotation speed (replacement required 1)
Fan sticking (replacement required 2)
Abnormal rotation speed and fan sticking
Energy saving mode
114
Message
No errors are detected.
The speed of the fan decreased.
The boot error is detected.
The boot error is detected.
Energy-saving mode is in operation.
B-64805EN/03
History screen
8.
History screen
8.1.
Message History
The Message History screen displays a list of alarm and other message history.
8.1.1.
Displaying the Message History screen
The Message History screen can be displayed by doing the following.
Press [History] in the Maintenance category of the Menu screen
Press the vertical soft key [Message History]
8.1.2.
Names and functions of each part of the Message History screen
Constitution
The figure below shows a layout of the Message History screen.
Fig. 8.1.2-1 Names and functions of each part of the Message History screen
Table 8.1.2-1 Names and functions of each part of the Message History screen
Symb
ol
Name
Contents
A
List display section
Displays the Message History screen
B
Detail display section
Displays the details of the Message History screen
115
History screen
B-64805EN/03
Symb
ol
Name
Contents
C
Guidance message display section
Displays a list of display guidance messages
List display section
The following information is displayed in the List display section.
• Date
• Time
• Type
• Number
• Message
The type and number format of the display target is as follows.
Type
Number format
Display example
Alarm type
<alarm type><alarm number>
SW0100
Operator message history
<message>(<message number> or EX<message number>)
Operator
message(EX0001)
Detail display section
The Detail display section displays detailed information about the history currently selected in the List display section.
The display content varies by type.
If no history data exists, the Detail display section is not displayed.
The Alarm history displays the following detailed information.
• Alarm type and number
• Path number
• Axis number (absolute axis number + 1000 for flexible axis switching)
• Date
• Time
• Message
If bit 7 (HAL) of parameter No. 3196 is 0 and bit 2 of No. 11354 is 0, the following additional information is also
displayed.
• Modal G code
• B,D,E,F,H,M,N,O,S,T code modal value
• Absolute coordinate value when an alarm occurs
• Machine coordinate value when an alarm occurs
The operator message history displays the following information.
• Message (message number if available for display)
• Date
• Time
Soft keys
The placement of the soft keys and their operation when pressed are as follows.
Caption
Display
conditio
ns
Gray-out conditions
Operation when pressed
Switch target
None
None
Toggles focus between List and Detail display sections
116
B-64805EN/03
Caption
Display
conditio
ns
History screen
Gray-out conditions
Operation when pressed
Delete All
No.3195
#7=1
None
Displays the Delete All popup screen
Top
None
None
Moves the cursor to the top of the table
Bottom
None
None
Moves the cursor to the end of the table
Filter
None
None
Displays the Filter popup screen
Refresh
None
None
Reloads and displays message history
All soft keys are displayed even if no history data exists.
8.1.3.
Operating the Message History screen
Filter function
You can filter the message history to be displayed by following the steps below.
Press the horizontal soft key [Filter] to display the filter popup screen
Enter the filter conditions in the input field of the filter popup screen
Press the [OK] horizontal soft key
If you do not wish to filter using the information entered in the filter popup screen, press the horizontal soft key
[Cancel].
8.2.
Operation history
The Operation History screen displays a list of the operator's operation history.
8.2.1.
Displaying the Operation History screen
The Operation History screen can be displayed only when bit 4 of parameter No. 3106 is set to 1.
The Operation History screen can be displayed by doing the following.
Press [History] in the Maintenance category of the Menu screen
Press the vertical soft key [Operation History]
History sampling is stopped while the Operation History screen is being displayed.
8.2.2.
Names and functions of each section of the Operation History Screen
Constitution
The figure below shows a layout of the Operation History screen.
117
History screen
B-64805EN/03
Fig. 8.2.2-1 Names and functions of each section of the Operation History screen
Table 8.2.2-1 Names and functions of each section of the Operation History screen
Sym
bol
A
B
C
Name
Contents
List display section
Detail display section
Guidance message display section
Displays the Message History screen
Displays the details of the Message History screen
Displays a list of display guidance messages
List display section
The List display section shows a list of operation history. The information displayed is as follows.
• Date
• Time
• Type
• Overview
The type and overview format of the display target is as follows.
Type
MDI key operation
Signal
Alarm
Date/time
Modify Macro common var
118
Number format
<MDI key name>
<signal name><signal number>: <bit string before change>><bit string after change>
<alarm type><alarm number>
<event type>
<custom macro advisor variable number>: <before change>><after change>
Display example
A
Operator
message(EX0001)
SW0100
Power Off
#123: 1.23 -> 2.34
B-64805EN/03
History screen
Type
Parameter transition
External operator message
Modify Tool offset
Work offset transition
Number format
No.<parameter number>[#bit]: <before change>-><after
change>
<message>(<message number> or EX<message number>)
<tool offset data type><tool offset number>: <before
change>-><after change>
<workpiece offset data type><workpiece offset number>:
<before change>-><after change>
Display example
No.3281: 0->1
Operator message
(EX0001)
ZW1: 0->1
Volume of workpiece
shift 1: 1.234->2.345
If no history data exists, the List display section, including the table header section, will not be displayed
Detail display section
The Detail display section displays detailed information about the history currently selected in the List display section.
The display content varies by type.
If no history data exists, the Detail display section is not displayed.
MDI key operation
The MDI key operation displays the following detailed information.
• Key code
•
Displays the virtual key code instead of the MDI key code
• Path number
• Date
• Time
Signal
Only signals registered from the Operation History Signal Selection screen are displayed.
The following detailed information is displayed in Signals.
• Signal name/number
• Bit pattern before change
• Bit pattern after change
• PMC number
• Date
• Time
Alarm
The following detailed information is displayed in Alarm.
• Alarm type and number
• Path number
• Axis number (absolute axis number + 1000 for flexible axis switching)
• Date
• Time
• Alarm message (not displayed for some alarms)
If bit 7 (HAL) of parameter No. 3196 is 0, the following additional information is also displayed.
• Modal G code
• B,D,E,F,H,M,N,O,S,T code modal value
• Absolute coordinate value when an alarm occurs
119
History screen
B-64805EN/03
• Machine coordinate value when an alarm occurs
Date/time
The following detailed information is displayed in Date/time.
• Event type (power off, power on, date change, time stamp, or data erase)
• Date
• Time
Modify Macro common var
Modify Macro common var displays the following detailed information.
• Macro Common Var Number
• Date
• Time
• Path number
• Common variable data before change
• Common variable data after change
Parameter transition
The following detailed information is displayed in Parameter transition.
• Parameter data type (axis type, spindle type, path type, or machine group type)
• (One of the following)
•
Absolute axis number (when the parameter data type is axis type)
•
Absolute spindle number (when the parameter data type is spindle type)
•
Path number (when the parameter data type is path type)
•
Machine group number (when the parameter data type is machine group type)
• Date
• Time
• Parameters number (0-99999)
• Data before change
• Data after change
External operator message
The external operator message displays the following detailed information.
• Operator message string and message number
• Date
• Time
Message numbers for external operator messages are displayed only up to the set value -1 for parameter No. 6310.
When bit 1 of parameter No. 6301 is 0, the message number is displayed with 2000 added to it. When bit 1 of
parameter No. 6301 is 1, the message number is displayed with the string "EX" prefixed to it.
Modify Tool offset
The following detailed information is displayed in Modify Tool offset.
• Data type (one of the following)
120
•
Tool offset
•
Geometry offset
•
Wear offset
•
Tool length offset (geometry)
B-64805EN/03
•
Tool length offset (wear)
•
Cutter compensation (geometry)
•
Cutter compensation (wear)
•
X-axis tool offset
•
Z-axis tool offset
•
X-axis tool offset (geometry)
•
X-axis tool offset (wear)
•
Z-axis tool offset (geometry)
•
Z-axis tool offset (wear)
•
Tool tip radius compensation
•
Tool tip radius compensation (geometry)
•
Tool tip radius compensation (wear)
•
Y-axis tool offset
•
Y-axis tool offset (geometry)
•
Y-axis tool offset (wear)
•
Cutting tool direction
•
X-axis second geometry offset
•
Z-axis second geometry offset
•
Y-axis second geometry offset
History screen
• Offset number
• Date
• Time
• Path number
• Data before change
• Data after change
Work offset transition
The following detailed information is displayed in Work offset transition.
• Data type
•
Workpiece offset
•
Workpiece offset extension
•
Volume of workpiece shift
• Offset number
• Date
• Time
• Path number
• Relative axis number in the path
• Data before change
• Data after change
Soft keys
The placement of the soft keys and their operation when pressed are as follows.
121
History screen
Caption
Switch target
Delete All
Top
End
Filter
Select Signal
Display
condition
s
None
No.3195#
7=1
None
None
None
None
B-64805EN/03
Gray-out conditions
Operation when pressed
None
None
Toggles focus between List and Detail display sections
Displays the Delete All popup screen
None
None
None
None
Moves the cursor to the top of the table
Moves the cursor to the end of the table
Displays the Filter popup screen
Displays the Operation History Signal Selection screen
All soft keys are displayed even if no history data exists.
8.2.3.
Operating the Operation History screen
Filter function
You can filter the operation history to be displayed by following the steps below.
Press the horizontal soft key [Filter] to display the filter popup screen
Enter the filter conditions in the input field of the filter popup screen
Press the [OK] horizontal soft key
If you do not wish to filter using the information entered in the filter popup screen, press the horizontal soft key
[Cancel].
Select Signal
The following procedure can be used to register signals to be recorded in the operation history. You can set up to 60
signals.
Press the horizontal soft key [Select Signal] to display the Operation History Signal Selection screen
Follow the guidance and enter the settings in the table cells. (The background color of the edited line
is yellow)
Press the soft key [Reflect] (the background color of the line whose settings are reflected in CNC will
change from yellow to white)
If the setting fails when the soft key [Reflect] is pressed, the background color of the failed line is displayed in red.
8.3.
System alarm history
The System Alarm History screen displays the system alarm history.
The five most recent system alarms that have occurred in the past are stored and displayed.
Log files for system alarms can be output from the Data I/O Screen. For details, see the description of the
Data I/O Screen.
8.3.1.
Displaying the System Alarm History screen
The System Alarm History screen can be displayed by doing the following.
Press [History] in the Maintenance category of the Menu screen
Press horizontal soft key [System Alarm His.]
122
B-64805EN/03
8.3.2.
History screen
Names and functions of each section of the System Alarm History
screen
Constitution
The figure below shows a layout of the System Alarm History screen.
Fig. 8.3.2-1 Names and functions of each section of the System Alarm History screen
Table 8.3.2-1 Names and functions of each section of the System Alarm History screen
Sym
bol
Name
A
Contents
System alarm overview display
section
System alarm data display section
B
Displays an overview of the system alarm
Displays binary data of the system alarm
Soft keys
The placement of the soft keys and their operation when pressed are as follows.
Caption
Display
conditio
ns
Gray-out conditions
Top
None
None
Bottom
None
None
Previous page
None
None
Operation when pressed
Goes to the top of the system alarm data display
section
Goes to the bottom of the system alarm data display
section
Goes to the previous page of the system alarm data
display section
123
History screen
Caption
B-64805EN/03
Display
conditio
ns
Gray-out conditions
Next page
None
None
System alarm 1
None
System alarm 2
None
System alarm 3
None
System alarm 4
None
System alarm 5
None
When the screen is displayed for
the first time or [System Alarm 1]
is pressed
When [System alarm 2] is
pressed
When [System alarm 3] is
pressed
When [System alarm 4] is
pressed
When [System alarm 5] is
pressed
All soft keys are displayed even if no history data exists.
124
Operation when pressed
Goes to the next page of the system alarm data
display section
Displays SYS_ALM1.BIN information on the screen
Displays SYS_ALM2.BIN information on the screen
Displays SYS_ALM3.BIN information on the screen
Displays SYS_ALM4.BIN information on the screen
Displays SYS_ALM5.BIN information on the screen
III Interface configuration
B-64805EN/03
1.
Interface between CNC and PMC
Interface between CNC and PMC
This section describes the function of PMC and the interfaces between CNC and PMC.
1.1.
What is PMC?
PMC (Programmable Machine Controller) is a PLC (Programmable Logic Controller) function built into FANUC's
CNCs.
This function controls the connection between the CNC and various components of the machine tool (such as
operator's panel) and the connection between the machine tool and peripheral devices (such as parts loader).
Fig. 1.1-1 Configuration of PMC function
A program executed by PMC is called the sequence program.
Sequence programs are created by the Ladder language or the ST (Structured Text) language.
NOTE
For details on the PMC function, see "Series 500i-A PMC PROGRAMMING MANUAL" (B-64803EN-3).
1.1.1.
Basic Configuration of PMC
In PMC, the PMC system software executes sequence programs stored in the program memory to process the
signals and the variables in the data memory.
127
Interface between CNC and PMC
B-64805EN/03
Fig. 1.1.1-1 Basic Configuration of PMC
1.1.2.
PMC Program Memory
The PMC program memory includes the program memory for editing and the program memory for execution.
At CNC startup or PMC data input/output, data is loaded first into the program memory for editing. In each PMC
screen and FANUC PMC Programmer, data in the program memory for editing is viewed and edited.
Then, the data necessary for sequence program execution is loaded into the program memory for execution.
The following is an example of loading a sequence program. Although sequence programs include title data and
variable data in addition to program codes written in the Ladder language or ST language, only program codes are
loaded into the program memory for execution.
128
B-64805EN/03
Interface between CNC and PMC
Fig. 1.1.2-1 Program memory for editing and execution
Program memory for editing
The program memory for editing is used to view and edit the following data.
Table 1.1.2-1 List of data stored in program memory for editing
Data type
Sequence program
PMC units
Remark
Main sequence program.
PMC1 to PMC5, DCSPMC
Sub-sequence program.
PMC1 to PMC5
DCSPMC is common to
DCSPMC1 and DCSPMC2
Sub-sequence numbers 01
to 99 for each PMC unit
PMC message data
I/O Link i assignment data
PMC1 to PMC5
(Common)
The total size of the above data must be less than or equal to the size of the program memory for editing.
The size of the program memory for editing can be specified with the PMC program memory option.
Table 1.1.2-2 Types of PMC program memory options
Types of PMC program memory options
Size of program memory for editing
Basic functions
1MB
"PMC program memory (3MB)" option
3MB
"PMC program memory (10MB)" option
10MB
If the total size of the data exceeds the size of the program memory for editing, the following alarms occur.
129
Interface between CNC and PMC
B-64805EN/03
• "PMC3002 SEQUENCE PROGRAM ERROR (TOO LARGE SIZE)"
• "PMC9041 PMC MESSAGE DATA ERROR (TOO LARGE SIZE)"
• "IOL2001 I/O LINK I ASSIGNMENT DATA ERROR (TOO LARGE SIZE)"
Program memory for execution
The program memory for execution is memory that stores data necessary for execution, such as program codes in
sequence programs.
The size of the program memory for execution is 4 MB per unit for PMC1 to PMC5 and 104 KB for DCSPMC.
Fig. 1.1.2-2 Data in program memory for execution
Create sequence programs so that the program code does not exceed the size limit. If the size limit is exceeded, the
following alarms are generated for each PMC unit.
• "PMC3007 PROGRAM EXECUTION MEMORY OVER"
1.1.3.
PMC data memory
PMC data memory includes PMC-addressed memory and PMC-unaddressed memory. In addition, each memory has
a retained area and a volatile area.
Fig. 1.1.3-1 Data memory configuration
NOTE
E addresses are placed in the retained area when the "nonvolatile extra relay function" option is added, and in the
volatile area when the option is not added.
130
B-64805EN/03
Interface between CNC and PMC
Since each memory has the following characteristics, it is recommended that the PMC-addressed memory be used to
interface with other functions and the PMC-unaddressed memory be used for other purposes.
PMC-addressed memory
The PMC-addressed memory is suitable for interfacing with other functions because the address at which data is
stored can be fixed.
PMC-unaddressed memory
The PMC-unaddressed memory is optimally allocated by the compiler so that memory can be used efficiently without
duplication.
1.1.3.1.
PMC Address
A PMC address consists of an address symbol, address number, and bit position as shown in the figure below.
However, when addressing in bytes, no "." (period) and bit position are required. In the example below, it is
represented as "%X127".
Fig. 1.1.3.1-1 Representation of PMC address
A
Address symbol
B
Address number
C
Bit position (0 to 7)
Each address symbol represents the following signal types.
Table 1.1.3.1-1 Address symbol type
Symbol
Attribute
Description
F
Volatile, non-writable
G
Volatile
X
Volatile, non-writable
Y
Volatile
M
Volatile, non-writable
N
Volatile
R
Volatile
E
Retained/Volatile
The F-address is an input signal from CNC to PMC.
See III.1.3.3. Signals from CNC to PMC(P.175) for details.
The G-address is an output signal from PMC to CNC.
See III.1.3.2. Signals from PMC to CNC(P.145) for details.
The X-address is an input signal to the PMC from an external device connected via
I/O Link i, etc.
The Y-address is an output signal from the PMC to external devices connected via
I/O Link i, etc.
The M-address is an input signal from another PMC unit when the multi-unit PMC
function or the dual check safety function is used.
The N-address is an output signal to another PMC unit when the multi-unit PMC
function or the dual check safety function is used.
The R-address is an internal relay used as a work in the sequence program.
Usually, the PMC-unaddressed memory for variables is used as a work for a
sequence program, but internal relays are more suitable when you want to fix
addresses, such as when interfacing with other applications.
As with an R-address, an E-address is a memory area used as a work in a
sequence program.
When the multi-unit PMC function is used, it can be used as shared memory
among PMC units.
It can also be used as an extended area for D-addresses by adding the
"nonvolatile extra relay function" option.
131
Interface between CNC and PMC
B-64805EN/03
Symbol
Attribute
Description
Z
Volatile, non-writable
A
Volatile, partially
writable
The Z-address is a system relay for referencing the status of the PMC system.
Writing to a Z-address is not possible.
The A-address is a signal used to display alarm messages and operator messages
on the CNC screen using the message display function.
The A-address has the following two areas.
T
Retained
Area
Range(*)
Display request signal
Display status signal
%A0 to %A749
%A9000 to %A9749
Range(*)
TMR (SUB 3) setting
values and work
TMR (SUB 3)
accuracy
Retained
%T9000 to %T9999
The C-address is a PMC parameter used in the functional instructions CTR (SUB
5) and CTRB (SUB 56).
The C-address has the following two areas.
Range(*)
Setting values and
current values of CTR
(SUB 5)
Current value of
CTRB (SUB 56)
Retained
Retained/Volatile
S
Volatile
L
Nonreadable/writable
P
Nonreadable/writable
Description
%C0 to %C1199
%C5000 to %C5599
The K-address is a boolean type PMC parameter.
The K address has the following two areas.
Area
D
Description
%T0 to %T999
Area
K
Non-writable
The T-address is a PMC parameter used to configure the functional instruction
TMR (SUB 3).
A T-address has the following two areas.
Area
C
Description
Range(*)
User area
%K0 to %K299
System area
%K9000 to %K9499
Description
This is a general-purpose
keep-relay that can be used
freely in sequence programs.
This is a keep-relay for setting
the PMC system software
operation.
The D-address is a general-purpose PMC parameter whose data type can be set
with data table control data.
The standard retained area is %D0 to %D19999. The "nonvolatile data table area
extension (40KB)" option is required to retain the entire area of %D0 to %D59999.
The S-address is a signal used in the step sequence function.
Do not use the step sequence function as it is not supported at this time.
The L-address is a label number used for the functional instructions LBL (SUB 69),
JMPB (SUB 68), and JMPC (SUB 73).
Since an L-address is not located in physical memory, the value cannot be read or
written.
The P-address is a subprogram number used for the functional instructions CALL
(SUB 65), CALLU (SUB 66), and CM (SUB 75).
Since a P-address is not located in physical memory, the value cannot be read or
written.
NOTE
The valid range of each type of PMC addresses depends on the PMC unit. For details, refer to " Table 1.1.5-2(P.137)".
132
B-64805EN/03
1.1.3.2.
Interface between CNC and PMC
Retained Data Memory
The following data is stored in the retained data memory of the PMC and is saved in the nonvolatile memory so that
the data is not lost even if the main power of the CNC is turned off.
• Variables with RETAIN attribute
• PMC parameters (T, K, C, D, and E(*)-addresses)
Retained data is stored in the nonvolatile memory besides the data memory that the sequence program references
during execution, and is copied every 200ms.
Therefore, it takes up to 200ms for the value to be retained after it is written to the retained data memory.
Be sure to turn off the CNC power at least 200ms after the value is written to the retained data memory.
NOTE
E-addresses are retained only when the "nonvolatile extra relay function" option is added.
1.1.4.
FANUC I/O LINK i CONNECTIONS
FANUC I/O Link i is a high-speed serial interface for connecting the machine operator's panel and sensors to the
CNC.
To connect to the CNC, set the I/O signal address of each I/O unit in the I/O Link i allocation data.
133
Interface between CNC and PMC
B-64805EN/03
Fig. 1.1.4-1 FANUC I/O LINK i CONNECTIONS
NOTE
1. This function is different from IO-Link specified in IEC61131-9.
2. FANUC I/O Link cannot be used. I/O units that are not compatible with FANUC I/O Link i cannot be connected.
3. Sequence program execution and I/O Link i signal transfer are handled asynchronously. Depending on the
execution timing of the sequence program, I/O signal transfer may be delayed or accelerated by one cycle.
1.1.4.1.
FANUC I/O LINK i Specifications
FANUC I/O Link i uses the following terminology.
Channel
Represents one line in a daisy chain connection.
Group
Represents the allocation unit of the I/O unit. Depending on the type of the I/O unit, an I/O unit is allocated in units of
one or two groups.
Slot
Represents the module connection position of the module type I/O unit.
Basic specifications
The maximum number of channels that can be used is 3. Up to 2048 input signals and 2048 output signals can be
used per channel.
In a multi-unit PMC, input and output signals of one channel are allocated to multiple PMC units.
With FANUC I/O Link i, two communication modes (normal mode and high-speed mode) can be set for each group. It
is also possible to mix groups in both the normal communication mode and high-speed mode for a single channel.
Table 1.1.4.1-1 Basic specifications of FANUC I/O LINK i
Edit mode
Item
Normal mode
Transfer rate
Transfer interval
134
High-speed mode
12Mbps
2ms
0.5ms
B-64805EN/03
Interface between CNC and PMC
Edit mode
Item
Normal mode
Maximum number of
channels
Maximum number of
groups
(per channel)
Maximum number of
I/O points
(per channel)
Maximum number of
I/O points
(per group)
High-speed mode
3
24
12 (safety I/O) (*1)
5
5 (safety I/O) (*1)
Input: 2048 / Output: 2048
Input: 512 / Output: 512
Input: 512 / Output: 512(*2)
Input: 224 / Output: 224 (safety I/O)
NOTE
1. Up to 12 groups of safety I/Os can be connected for DCSPMC1 and DCSPMC2, respectively, for a total of three
channels.
2. If groups in the normal mode and the high-speed mode are mixed for one channel, the maximum number of points
per group will be less than 512/512 points.
1.1.4.2.
FANUC I/O Link i allocation
FANUC I/O Link i allocates addresses and sizes of input signals (X-address) and output signals (Y-address) to
channels, groups, and slots to which I/O units are connected.
Table 1.1.4.2-1 Example of FANUC I/O Link i allocation
Channel
Group
Slot
X-address
X-address size
Y-address
Y-address size
1
0
1
%X0
2
%Y0
2
1
0
2
%X2
2
%Y2
2
1
1
1
:
Channel setting items
Group allocation selection function
Enable or disable the I/O Link i group allocation selection function.
Group setting items
High-speed mode
Set whether to use the high-speed mode or not.
Safety I/O
Set whether to use an I/O unit connected to the group as a safety I/O or not.
Manual pulse generator
Set whether to use the manual pulse generator used or not.
Slice I/O
Set whether to use FANUC Slice I/O or not.
Slot setting items
Slot number
Set the slot number.
In the case of a multi-unit PMC, a PMC unit and address are allocated to each slot. This allows addresses of multiple
PMC units to be used in a single channel.
135
Interface between CNC and PMC
B-64805EN/03
NOTE
If "manual pulse generator" is set to "enabled" in the group settings, "MPG" is displayed for the slot number.
PMC units
Set a PMC unit.
When "Safety I/O" is "disabled": set PMC1 to PMC5.
When "Safety I/O" is "enabled": Set DCSPMC1 or DCSPMC2 in the group settings.
X-address
Set the X-address to be allocated to input signals of the I/O unit.
X size
Set the transfer data length of the I/O unit's input signals in bytes.
Y-address
Set the Y-address to be allocated to output signals of the I/O unit.
Y size
Set the transfer data length of the I/O unit's output signals in bytes.
Slice I/O setting
Module type
Set the module type of FANUC Slice I/O.
Setting items
Set the setting items for each module set in Module type.
1.1.5.
Basic Specifications of the PMC
Table 1.1.5-1 Basic specifications for each PMC unit
Function
Multi-unit PMC function
Sub-sequence program function
The maximum number (including the main
sequence program)
File number
Program organization unit (POU)
Programming language
Number of program execution levels
1st level execution cycle
Basic instruction processing speed
Instruction type
Basic instruction
Functional instruction
Program memory
Program memory for editing
Program memory for execution
Data memory
Memory for variables (volatile area)
136
PMC1 to PMC5
Max. 5 units
DCSPMC1, DCSPMC2
2 paths (*1)
None
Max. 40 (for the entire PMC)
1 to 99 (for each PMC unit)
Function
Function block
Subprogram
Ladder
ST language
2 (for each sequence program)
1, 2, 4, 8ms (for the entire PMC)
Function
Function block
Subprogram
Ladder
4ns
2 (shared by DCSPMC1 and 2)
4, 8, 16ms (shared by DCSPMC1
and 2)
180ns
24
359
24
244
Max. 10MB (for the entire PMC)
(*2)
4MB (for each PMC unit)
(Included in the number in the left
column)
104KB (used by DCSPMC1 and 2
respectively)
128KB (for the entire PMC)
B-64805EN/03
Interface between CNC and PMC
Function
PMC1 to PMC5
Memory for variables (retained area)
PMC Address
DI/DO
Input (X)
Output (Y)
Variable definition
Variable name
Comment
DCSPMC1, DCSPMC2
64KB (for the entire PMC) (*3)
(See Table 1.1.5-2.)
10KB (used by DCSPMC1 and 2
respectively)
4KB (used by DCSPMC1 and 2
respectively)
(See Table 1.1.5-2.)
Max. 6.144 points (for the entire
PMC) (*4)
Max. 6.144 points (for the entire
PMC) (*4)
Max. 2,688 points (used by
DCSPMC1 and 2 respectively)
Max. 2,688 points (used by
DCSPMC1 and 2 respectively)
Max. 127 characters
Max. 511 bytes × 4 sets
Max. 127 characters
Max. 511 bytes × 4 sets
NOTE
1. In the case of DCSPMC, one sequence program is executed for two paths: DCSPMC1 and DCSPMC2.
2. This is the total size of the sequence programs for PMC1 to PMC5 and DCSPMC, I/O Link i allocation data, and
PMC message data.
3. The standard size of the retained data is 32KB. To retain the entire 64KB, the "required memory extension for
PMC variables (32KB)" option is required.
4. This number includes the points for DCSPMC1 and DCSPMC2.
Table 1.1.5-2 PMC address list
Memory type
Attribute
Input from CNC
Volatile, non-writable
Output to CNC
Volatile
Input from external
device
Volatile, non-writable
Output to external
device
Volatile
Input from other PMC
unit
Volatile, non-writable
Output to other PMC
unit
Volatile
PMC1
PMC2 to PMC5
DCSPMC1,
DCSPMC2
%F0 to %F999
%F0 to %F999
%F0 to %F127
:
:
%F1000 to %F1127
%F29000 to %F29999 %F29000 to %F29999 %F2000 to %F2255
%F3000 to %F3255
%F4000 to %F4767
%F5000 to %F5767
%F6000 to %F6511
%F7000 to %F7511
%G0 to %G999
%G0 to %G999
%G0 to %G127
:
:
%G1000 to %G1127
%G29000
%G29000
%G2000 to %G2255
to %G29999
to %G29999
%G3000 to %G3255
%G4000 to %G4767
%G5000 to %G5767
%G6000 to %G6511
%G7000 to %G7511
%X0 to %X127
%X0 to %X127
%X0 to %X127
%X200 to %X327
%X200 to %X327
%X200 to %X327
%X400 to %X527
%X400 to %X527
%X400 to %X527
%X600 to %X727
%X600 to %X727
%X600 to %X727
%X1000 to %X1127
%X1000 to %X1127
%X1000 to %X1127
%Y0 to %Y127
%Y0 to %Y127
%Y0 to %Y127
%Y200 to %Y327
%Y200 to %Y327
%Y200 to %Y327
%Y400 to %Y527
%Y400 to %Y527
%Y400 to %Y527
%Y600 to %Y727
%Y600 to %Y727
%Y600 to %Y727
%Y1000 to %Y1127
%Y1000 to %Y1127
%Y1000 to %Y1127
%M0 to %M767
%M0 to %M767
%M0 to %M127
%M1000 to %M1127
%M2000 to %M2127
%N0 to %N767
%N0 to %N767
%N0 to %N127
%N1000 to %N1127
%N2000 to %N2127
137
Interface between CNC and PMC
Memory type
B-64805EN/03
Attribute
PMC1
Internal relay
System relay
Extra relay
Volatile
Volatile, non-writable
Retained/Volatile (*1)
Message display
Display request
Display status
Timer
Setting value
Accuracy
Counter
Variable counter
Fixed counter
Keep relay
User area
System area
Data table
Label
Subprogram
Retained, partially
non-writable
DCSPMC1,
DCSPMC2
PMC2 to PMC5
%R0 to %R59999
%Z0 to %Z999
%E0 to %E9999
%R0 to %R15999
%Z0 to %Z999
(Shared with PMC1)
(*2)
%R0 to %R1499
%Z0 to %Z999
(None)
%A0 to %A749
%A9000 to %A9749
%A0 to %A499
%A9000 to %A9499
%T0 to %T999
%T9000 to %T9999
%T0 to %T999
%T9000 to %T9999
%T0 to %T79
%T9000 to %T9079
%C0 to %C1199
%C5000 to %C5599
%C0 to %C799
%C5000 to %C5399
%C0 to %C79
%C5000 to %C5039
%K0 to %K299
%K9000 to %K9499
%D0 to %D59999 (*3)
%L1 to %L9999
%P1 to %P5000
%K0 to %K199
%K9000 to %K9499
%D0 to %D19999
%L1 to %L9999
%P1 to %P5000
%K0 to %K99
%K9000 to %K9499
%D0 to %D2999
%L1 to %L9999
%P1 to %P2000
(None)
Retained
Retained
Retained
Retained
Non-readable/writable
Non-readable/writable
NOTE
1. Volatile by default, but can be changed to be nonvolatile with the option.
2. The same memory is shared by PMC1 to PMC5.
3. The standard area to be retained is %D0 to %D19999. The "nonvolatile data table area extension (40KB)" option
is required to retain the entire area of %D0 to %D59999.
Table 1.1.5-3 PMC parameter list
Parameters
Timer
Counter
Keep relay (user area)
Keep relay (system area)
Data table control group
Data table
Extra relay control group
Extra relay (*2)
PMC1
PMC2 to PMC5
1 to 500
1 to 300
%K0 to %K299
%K9000 to %K9499
1 to 100
%D0 to %D59999 (*1)
1 to 100
%E0 to %E9999
1 to 500
1 to 200
%K0 to %K199
%K9000 to %K9499
1 to 100
%D0 to %D19999
1 to 100
(Shared with PMC1)
(*3)
DCSPMC1,
DCSPMC2
1 to 40
1 to 20
%K0 to %K99
%K9000 to %K9499
1 to 100
%D0 to %D2999
(None)
(None)
NOTE
1. The standard area to be retained is %D0 to %D19999. The "nonvolatile data table area extension (40KB)" option
is required to retain the entire area of %D0 to %D59999.
2. Volatile by default, but can be changed to be nonvolatile with the option.
3. The same memory is shared by PMC1 to PMC5.
Table 1.1.5-4 List of functional instructions specifying a number
Functional instruction
Variable timer (TMR)
Fixed timer (TMRB/TMRBF)
Variable counter (CTR)
Fixed counter (CTRB)
138
PMC1
500
1500
300
300
DCSPMC1,
DCSPMC2
PMC2 to PMC5
500
1000
200
200
40
100
20
20
B-64805EN/03
Interface between CNC and PMC
Functional instruction
Rise/Fall detection (DIFU/DIFD)
Label (LBL)
Subprogram (SP)
1.2.
PMC1
3000
9999
5000
DCSPMC1,
DCSPMC2
PMC2 to PMC5
2000
9999
5000
256
9999
2000
Operating the PMC screen
In the PMC screen, various PMC data and programs can be displayed and operated.
PMC data can be checked and edited to start up and maintain the machine.
Fig. 1.2-1 PMC screen
The main features of the PMC screen are as follows.
1. Checking I/O signal status between the CNC and PMC
You can check the status of input/output signals between the CNC and PMC.
2. Checking I/O unit connection status
You can check if I/O units connected via I/O Link i are properly connected. I/O unit assignments can also be
edited.
3. Diagnosing sequence programs
You can check the execution status, processing time (scan time), and variable values of sequence programs.
4. Editing sequence programs
You can edit sequence programs and variables.
For the features above, the screen used to operate the PMC includes the following screens.
139
Interface between CNC and PMC
B-64805EN/03
Table 1.2-1 List of screens used for PMC operation
Screen
Contents
PMC status screen
Screen title
I/O Link i screen
PMC variables
screen
PMC parameter
screen
PMC signal status
screen
Message screen
Program screen
PMC trace screen
Data I/O screen
Message screen
Boot screen
You can view the PMC execution status and alarms.
You can view the title of each data file.
You can view the status of connection between the CNC and I/O units.
You can view variables defined in the PMC.
You can view and edit PMC parameters (timers, counters, keep relays, data tables, and extra
relays).
You can check the current values of all PMC signals.
You can check the message definitions used by the external alarm message function and the
message display status.
You can check programs that you have created according to the programming language.
Ladder diagram screen
ST monitor screen
You can check changes in the status of the PMC signal in chronological order.
You can input and output PMC data.
You can check PMC-related alarms.
You can maintain the following PMC data.
Clear the PMC permanent data memory
Stop the sequence program and start CNC
NOTE
1. For details on the PMC screen, see "Series 500i-A PMC PROGRAMMING MANUAL" (B-64803EN-3).
2. Use the data I/O screen to input and output PMC data. For details on the data I/O screen, see "Series 500i-A
OPERATOR'S MANUAL" (B-64804EN).
3. Use the message screen to view PMC-related alarms. For details on the message screen, see "Series 500i-A
OPERATOR'S MANUAL" (B-64804EN).
4. Use the BOOT screen to maintain PMC data. For details on the BOOT screen, see VII.3. CNC maintenance operation
(BOOT)(P.840).
1.3.
Input/output signal address table
Interface addresses among CNC and PMC are as follows:
[Example of controlling 1 path with 1 PMC]
[Example of controlling 3 paths using one PMC]
140
B-64805EN/03
Interface between CNC and PMC
[Example of controlling multi-path CNC using PMC system]
141
Interface between CNC and PMC
B-64805EN/03
NOTE
Each PMC of a multipath PMC system has an independent signal area. The F, G, X, and Y signal addresses of each
PMC begin with 0. In contrast, the F and G signal addresses from the CNC are fixed addresses in the order of path
number. Note that the F and G signal addresses programmed in each PMC sequence program are numbered
differently from the F and G signal addresses as viewed from the CNC.
Notation of signals
Fn000
Address
142
#7
OP#P
#6
SA#P
#5
STL#P
#4
SPL#P
#3
#2
Symbol (#0 to #7 indicates bit position. )
#1
#0
RWD#P
B-64805EN/03
Interface between CNC and PMC
If a signal is common to both lathe and machining center systems and it is valid only for one of the two models, it is
described as shown in the example below.
#7
Gn053
*CDZ#P
#6
SMZ#P
#5
#4
ROVLP#
#3
#2
#1
TMRON#
UINT#P
P
#0
P
[Example 1] *CDZ indicates that the signal is for the lathe system only while the other signals are common to both
lathe and machining center systems.
Gn515
#7
#6
#5
#4
#3
#2
#1
#0
PPK8#SV
PPK7#SV
PPK6#SV
PPK5#SV
PPK4#SV
PPK3#SV
PPK2#SV
PPK1#SV
[Example 2] PPK1 to PPK8 indicate that the signal is for the machining center system only.
NOTE
1. In X addresses in the table, the emergency stop signal for each machine group is *ESP<X0008.4>,
*ESP<X0008.0>, and *ESP<X008.1>, respectively.
2. For multi-path control, one of the following superscripts is attached to the top right of a symbol depending on the
signal type.
Path type (for path 1) : #1
Path type (for path 2) : #2
Path type (for path 3) : #3
#1 to #3 indicate that the signals are prepared exclusively for Path 1 to Path 3.
Path type : #P
Controlled axis type : #SV
Spindle type : #SP
In the G and F addresses in the table, #P, #SV, and #SP represent the signals provided for each path, each
controlled axis, and each spindle, respectively.
PMC axis control group type : #PX
#PX attached to a signal indicates the signal is provided for each PMC axis control group.
3. The signal consists of 8 bits (a signal with 8 different meanings) for one address.
4. The letter "n" in each address indicates the address position used in each path, as shown below.
Path 1
: n=0 (Nos. 0 to 999)
Path 2
: n=1 (Nos. 1000 to 1999)
:
:
Path 10
: n=9 (Nos. 9000 to 9999)
5. For a signal of controlled axis type, when the number of axes exceeds eight for each path, set parameter No. 3021
to address this situation.
1.3.1.
Signals from the Machine Tool to CNC
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
X0000
X0001
X0002
X0003
143
Interface between CNC and PMC
#7
X0004
SKIP#1
#7
#6
ESKIP
SKIP6#1
B-64805EN/03
#5
#4
#3
SKIP5#1
SKIP4#1
SKIP3#1
#2
#1
#0
SKIP2#1
SKIP8#1
SKIP7#1
#1
#0
#6
#5
#4
#3
#2
ESKIP
-MIT2#1
+MIT2#1
-MIT1#1
+MIT1#1
SKIP6#1
SKIP5#1
SKIP4#1
SKIP3#1
SKIP2#1
SKIP8#1
SKIP7#1
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
*DEC8#2
#6
*DEC7#2
#5
*DEC6#2
#4
*DEC5#2
#3
*DEC4#2
#2
*DEC3#2
#1
*DEC2#2
#0
*DEC1#2
#7
#6
#5
#4
*ESP
#3
#2
#1
(*ESP)
#0
(*ESP)
X0009
#7
*DEC8#1
#6
*DEC7#1
#5
*DEC6#1
#4
*DEC5#1
#3
*DEC4#1
#2
*DEC3#1
#1
*DEC2#1
#0
*DEC1#1
X0010
#7
*DEC8#3
#6
*DEC7#3
#5
*DEC6#3
#4
*DEC5#3
#3
*DEC4#3
#2
*DEC3#3
#1
*DEC2#3
#0
*DEC1#3
#6
#5
#4
#3
#2
#1
#0
SKIP5#3
SKIP4#3
SKIP3#3
SKIP2#3
SKIP8#3
SKIP7#3
#6
#5
#4
#3
#2
#1
#0
ESKIP#3
-MIT2#3
+MIT2#3
-MIT1#3
SKIP6#3
SKIP5#3
SKIP4#3
SKIP3#3
SKIP2#3
SKIP8#3
SKIP7#3
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
SKIP#2
ESKIP#2
SKIP5#5
SKIP4#2
SKIP3#2
SKIP2#2
SKIP8#2
SKIP7#2
#2
#1
#0
SKIP2#2
SKIP8#2
SKIP7#2
X0004
SKIP#1
X0005
X0006
X0007
X0008
#7
X0011
SKIP#3
#7
X0011
SKIP#3
ESKIP#3
SKIP6#3
X0012
X0013
SKIP6#2
#7
X0013
144
SKIP#2
#6
#5
#4
#3
ESKIP#2
-MIT2#2
+MIT2#2
-MIT1#2
SKIP6#2
SKIP5#2
SKIP4#2
SKIP3#2
B-64805EN/03
1.3.2.
Interface between CNC and PMC
Signals from PMC to CNC
Gn000
#7
ED7#P
#6
ED6#P
#5
ED5#P
#4
ED4#P
#3
ED3#P
#2
ED2#P
#1
ED1#P
#0
ED0#P
Gn001
#7
ED15#P
#6
ED14#P
#5
ED13#P
#4
ED12#P
#3
ED11#P
#2
ED10#P
#1
ED9#P
#0
ED8#P
Gn002
#7
ESTB#P
#6
EA6#P
#5
EA5#P
#4
EA4#P
#3
EA3#P
#2
EA2#P
#1
EA1#P
#0
EA0#P
#7
#6
#5
#4
#3
#2
#1
#0
#6
MFIN4#P
#5
MFIN3#P
#4
MFIN2#P
#3
FIN#P
#2
#1
#0
Gn004
#7
MFIN5#P
#7
BFIN#P
#6
AFL#P
#5
#4
#3
TFIN#P
#2
SFIN#P
#1
Gn005
#0
MFIN#P
#7
#6
SKIPP#P
#5
#4
OVC#P
#3
#2
*ABSM#P
#1
#0
SRN#P
#7
#6
#5
#4
#3
#2
#1
Gn003
Gn006
Gn007
RLSOT#P
EXLM#P
*FLWU#P
RLSOT3
Gn008
#7
ERS#P
#6
RRW#P
#5
*SP#P
#4
*ESP#P
#7
#6
#5
Gn010
#7
*JV7#P
#6
*JV6#P
Gn011
#7
*JV15#P
Gn012
Gn013
ST#P
STLK#P
#3
*BSL#P
#2
#1
*CSL#P
#0
*IT#P
#4
PN16#P
#3
PN8#P
#2
PN4#P
#1
PN2#P
#0
PN1#P
#5
*JV5#P
#4
*JV4#P
#3
*JV3#P
#2
*JV2#P
#1
*JV1#P
#0
*JV0#P
#6
*JV14#P
#5
*JV13#P
#4
*JV12#P
#3
*JV11#P
#2
*JV10#P
#1
*JV9#P
#0
*JV8#P
#7
*FV7#P
#6
*FV6#P
#5
*FV5#P
#4
*FV4#P
#3
*FV3#P
#2
*FV2#P
#1
*FV1#P
#0
*FV0#P
#7
*AFV7#P
#6
*AFV6#P
#5
*AFV5#P
#4
*AFV4#P
#3
*AFV3#P
#2
*AFV2#P
#1
*AFV1#P
#0
*AFV0#P
#7
#6
#5
#4
#3
#2
#1
ROV2#P
#0
ROV1#P
Gn009
Gn014
#0
RVS#P
#P
145
Interface between CNC and PMC
B-64805EN/03
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Gn018
#7
HS2D#P
#6
HS2C#P
#5
HS2B#P
#4
HS2A#P
#3
HS1D#P
#2
HS1C#P
#1
HS1B#P
#0
HS1A#P
Gn019
#7
RT#P
#6
MP4#P
#5
MP2#P
#4
MP1#P
#3
HS3D#P
#2
HS3C#P
#1
HS3B#P
#0
HS3A#P
#7
#6
#5
#4
#3
HS4D#P
#2
HS4C#P
#1
HS4B#P
#0
HS4A#P
#7
SVR08I#
#6
SVR07I#
#5
SVR06I#
#4
SVR05I#
#3
SVR04I#
#2
SVR03I#
#1
SVR02I#
#0
SVR01I#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
SVGN#P
DFSYC#P
#3
SVR12I#
#2
SVR11I#
#1
SVR10I#
#0
SVR09I#
P
P
P
P
#4
#3
#2
#1
#0
Gn015
Gn016
F1D#P
Gn017
Gn020
Gn021
Gn022
SVSP#P
#7
ALNGH#
#6
RGHTH#
#5
NOINPS#
P
P
P
HREV#P
HNDLF#P
Gn024
#7
EPN7#P
#6
EPN6#P
#5
EPN5#P
#4
EPN4#P
#3
EPN3#P
#2
EPN2#P
#1
EPN1#P
#0
EPN0#P
#7
EPNS#P
#6
Gn025
#5
EPN13#P
#4
EPN12#P
#3
EPN11#P
#2
EPN10#P
#1
EPN9#P
#0
EPN8#P
#7
#6
*SSTP4#
#5
#4
#3
#2
#1
PC4SLC
#0
PC3SLC
#P
#P
#2
#1
#0
Gn023
Gn026
#7
Gn027
Gn028
146
SWS4#P
SP
#6
CON#P
#5
*SSTP3#
#4
*SSTP2#
#3
*SSTP1#
SP
SP
SP
SWS3#P
SWS2#P
SWS1#P
#4
*SUCPF
A#SP
#3
#2
#1
#0
GR2#SP
GR1#SP
#7
PC2SLC
#6
SPSTPA
#5
*SCPFA#
#P
#SP
SP
B-64805EN/03
Interface between CNC and PMC
#7
#6
*SSTP#P
#5
SOR#P
#4
SAR#P
#3
GR32#SP
#2
GR31#SP
#1
GR22#SP
#0
GR21#SP
#7
SOV7#P
#6
SOV6#P
#5
SOV5#P
#4
SOV4#P
#3
SOV3#P
#2
SOV2#P
#1
SOV1#P
#0
SOV0#P
#7
PKESS2
#6
PKESS1
#5
#4
#3
#2
#1
#0
#P
#P
GR42#SP
GR41#SP
M3R#P
Gn032
#7
R08I#SP
#6
R07I#SP
#5
R06I#SP
#4
R05I#SP
#3
R04I#SP
#2
R03I#SP
#1
R02I#SP
#0
R01I#SP
#7
SIND#SP
#6
SSIN#SP
#5
SGN#SP
#4
Gn033
#3
R12I#SP
#2
R11I#SP
#1
R10I#SP
#0
R09I#SP
Gn034
#7
R08I2#SP
#6
R07I2#SP
#5
R06I2#SP
#4
R05I2#SP
#3
R04I2#SP
#2
R03I2#SP
#1
R02I2#SP
#0
R01I2#SP
#7
SIND2#SP
#6
SSIN2#SP
#5
SGN2#SP
#4
Gn035
#3
R12I2#SP
#2
R11I2#SP
#1
R10I2#SP
#0
R09I2#SP
Gn036
#7
R08I3#SP
#6
R07I3#SP
#5
R06I3#SP
#4
R05I3#SP
#3
R04I3#SP
#2
R03I3#SP
#1
R02I3#SP
#0
R01I3#SP
#6
SSIN3#SP
#5
SGN3#SP
#4
Gn037
#7
SIND3#SP
#3
R12I3#SP
#2
R11I3#SP
#1
R10I3#SP
#0
R09I3#SP
#7
*BECLP#
#6
*BEUCP
#5
#4
#3
#2
#1
#0
P
#P
SPPHS#P
SPSYC#P
SBRT#P
Gn029
Gn030
Gn031
Gn038
P
#7
P
#4
#3
#2
#1
#0
#P
OFN5#P
OFN4#P
OFN3#P
OFN2#P
OFN1#P
OFN0#P
#6
#5
#4
#3
#2
#1
#0
PRC#P
S2TLS#P
OFN9#P
OFN8#P
OFN7#P
OFN6#P
P
Gn041
#7
HS2ID#P
#6
HS2IC#P
#5
HS2IB#P
#4
HS2IA#P
#3
HS1ID#P
#2
HS1IC#P
#1
HS1IB#P
#0
HS1IA#P
#6
#5
#4
Gn042
#7
DMMC#P
#3
HS3ID#P
#2
HS3IC#P
#1
HS3IB#P
#0
HS3IA#P
#7
#6
#5
#4
#3
#2
#1
#0
Gn040
#6
WOQSM
*PLSST#
#5
Gn039
#7
GOQSM#
SDPC#P
WOSET#
147
Interface between CNC and PMC
Gn043
ZRN#P
B-64805EN/03
DNCI#P
MD4#P
MD2#P
MD1#P
#7
#6
#5
#4
#3
#2
#1
MLK#P
#0
BDT1#P
Gn045
#7
BDT9#P
#6
BDT8#P
#5
BDT7#P
#4
BDT6#P
#3
BDT5#P
#2
BDT4#P
#1
BDT3#P
#0
BDT2#P
#6
KEY4
#5
KEY3
#4
KEY2
#3
KEY1
#2
Gn046
#7
DRN#P
#1
SBK#P
#0
KEYP
Gn047
#7
TL128#P
#6
TL64#P
#5
TL32#P
#4
TL16#P
#3
TL08#P
#2
TL04#P
#1
TL02#P
#0
TL01#P
#7
#6
TLRSTI#
#5
#4
#3
#2
#1
#0
LFCIV#P
TL512#P
TL256#P
Gn044
Gn048
TLRST#P
P
TLSKP#P
#7
*TLV7#P
#6
*TLV6#P
#5
*TLV5#P
#4
*TLV4#P
#3
*TLV3#P
#2
*TLV2#P
#1
*TLV1#P
#0
*TLV0#P
Gn049
#7
#6
#5
#4
#3
#2
#1
*TLV9#P
#0
*TLV8#P
#7
#6
#2
#1
#0
CHPST#P
#4
CHPUP#
#3
*CHLD#P
#5
CHPDW
N#P
P
*CHP8#P
*CHP4#P
*CHP2#P
*CHP1#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Gn050
Gn051
Gn052
Gn053
148
*CDZ#P
SMZ#P
ROVLP#
TMRON#
UINT#P
P
P
Gn054
#7
UI007#P
#6
UI006#P
#5
UI005#P
#4
UI004#P
#3
UI003#P
#2
UI002#P
#1
UI001#P
#0
UI000#P
Gn055
#7
UI015#P
#6
UI014#P
#5
UI013#P
#4
UI012#P
#3
UI011#P
#2
UI010#P
#1
UI009#P
#0
UI008#P
Gn056
#7
UI023#P
#6
UI022#P
#5
UI021#P
#4
UI020#P
#3
UI019#P
#2
UI018#P
#1
UI017#P
#0
UI016#P
Gn057
#7
UI031#P
#6
UI030#P
#5
UI029#P
#4
UI028#P
#3
UI027#P
#2
UI026#P
#1
UI025#P
#0
UI024#P
#7
#6
#5
#4
#3
#2
#1
#0
B-64805EN/03
Interface between CNC and PMC
EXOUT#
Gn058
Gn059
Gn060
Gn061
Gn062
Gn063
Gn066
Gn067
Gn068
Gn069
#3
#2
#1
#0
TRRTN#P
TRESC#P
#7
*TSB#P
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
RGTSP4
RGTSP3
RGTSP2
RGTSP1
#SP
#SP
#SP
#SP
#7
HEAD2
#6
RTNT#P
#5
#4
#3
#2
#1
*CRTOF
#0
#7
#6
#5
#4
#3
#2
#1
#0
INFD#P
NOZAG
C#P
SLSPB#P
SLSPA#P
NOWT
HEAD
#6
ESRSYC
#5
#3
#2
#1
#0
SLPCB#P
SLPCA#P
#3
#2
#1
#0
#2
#1
#0
IGNVRY#
Gn064
Gn065
EXINP#P
#6
#7
#4
EXSTP#P
#7
NSYNC
A#P
NMWT#P
#5
P
#4
#P
#7
HCSKP4
#6
HCSKP3
#5
HCSKP2
#4
HCSKP1
#P
#P
#P
#P
HSRT#P
#7
#6
#5
#4
#3
RTRCT#P
EKSET
#7
#6
HCREQ
HCABT
#7
#6
MTLN07
#P
#5
RGTAP#
SYSS#P
P
ENBKY
#4
#3
#2
EGBS#P
MCHK#P
MMOD#P
#5
#4
#3
MTLN06
MTLN05
MTLN04
#P
#P
#P
#7
#6
#5
MTLN15
MTLN14
#P
#P
#1
CGREN#
P
#0
P
MTLC#P
#2
#1
#0
MTLN03
MTLN02
MTLN01
MTLN00
#P
#P
#P
#P
#4
#3
#2
#1
#0
MTLN13
MTLN12
MTLN11
MTLN10
MTLN09
MTLN08
#P
#P
#P
#P
#P
#P
149
Interface between CNC and PMC
Gn070
Gn071
Gn072
#7
MRDYA#
#6
ORCMA#
SP
SP
#7
#6
RCHA#SP
RSLA#SP
#7
RCHHG
A#SP
#7
B-64805EN/03
#5
#4
#3
CTH1A#S
#2
CTH2A#S
#1
TLMHA#
#0
TLMLA#S
SFRA#SP
SRVA#SP
P
P
SP
P
#5
INTGA#S
#4
SOCNA#
#3
MCFNA#
#2
SPSLA#S
#1
*ESPA#S
#0
ARSTA#
P
SP
SP
P
P
SP
#6
MFNHG
A#SP
#5
INCMDA
#4
OVRA#SP
#2
NRROA#
#1
ROTAA#
#0
INDXA#S
#SP
#3
DEFMD
A#SP
SP
SP
P
#6
#5
#4
#3
#1
DSCNA
SORSLA
#2
MPOFA#
#0
MORCM
A#SP
#5
#4
SFRB#SP
SRVB#SP
#5
INTGB#S
SP
SLVA#SP
#3
CTH1B#S
#2
CTH2B#S
#1
TLMHB#
#0
TLMLB#S
P
P
SP
P
#4
SOCNB#
#3
MCFNB#
#2
SPSLB#S
#1
*ESPB#S
#0
ARSTB#
P
SP
SP
P
P
SP
#4
#3
DEFMD
B#SP
#2
NRROB#
#1
ROTAB#
#0
INDXB#S
SP
SP
P
#2
MPOFB#
#1
#0
MORCM
B#SP
Gn073
Gn074
Gn075
Gn076
#7
MRDYB#
#6
ORCMB#
SP
SP
#7
#6
RCHB#SP
RSLB#SP
#7
RCHHG
B#SP
#6
MFNHG
B#SP
#5
INCMDB
#SP
OVRB#SP
#7
#6
#5
#4
#3
DSCNB
SORSLB
Gn077
Gn078
#6
SH06A#S
#5
SH05A#S
#4
SH04A#S
#3
SH03A#S
#2
SH02A#S
#1
SH01A#S
#0
SH00A#S
P
P
P
P
P
P
P
P
#7
#6
SH14A#S
#5
SH13A#S
#4
SH12A#S
#3
SH11A#S
#2
SH10A#S
#1
SH09A#S
#0
SH08A#S
P
P
P
P
P
P
P
#7
SH07B#S
#6
SH06B#S
#5
SH05B#S
#4
SH04B#S
#3
SH03B#S
#2
SH02B#S
#1
SH01B#S
#0
SH00B#S
P
P
P
P
P
P
P
P
#7
#6
SH14B#S
#5
SH13B#S
#4
SH12B#S
#3
SH11B#S
#2
SH10B#S
#1
SH09B#S
#0
SH08B#S
P
P
P
P
P
P
P
#6
EUI06#P
#5
EUI05#P
#4
EUI04#P
#3
EUI03#P
#2
EUI02#P
#1
EUI01#P
#0
EUI00#P
Gn081
Gn082
150
SLVB#SP
#7
SH07A#S
Gn079
Gn080
SP
#7
EUI07#P
B-64805EN/03
Gn083
Interface between CNC and PMC
#7
EUI15#P
#6
EUI14#P
#5
EUI13#P
#4
EUI12#P
#3
EUI11#P
#2
EUI10#P
#1
EUI09#P
#0
EUI08#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
-Ja#P
#2
+Ja#P
#1
-Jg#P
#0
+Jg#P
#7
MP42#P
#6
MP41#P
#5
#4
MP32#P
#3
MP31#P
#2
#1
MP22#P
#0
MP21#P
#7
#6
#5
#4
#2
#1
#0
HS4ID#P
HS4IC#P
HS4IB#P
HS4IA#P
#3
HNDMP#
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
G2SLC#P
G2Y#P
G2Z#P
G2X#P
G2RVY#P
G2RVZ#P
G2RVX#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
*HROV6#
#5
*HROV5#
#4
*HROV4#
#3
*HROV3#
#2
*HROV2#
#1
*HROV1#
#0
*HROV0#
P
P
P
P
P
P
P
#6
#5
#4
#3
#2
#1
#0
Gn084
Gn085
Gn086
Gn087
Gn088
P
Gn089
Gn090
Gn091
Gn092
Gn093
Gn094
Gn095
Gn096
HROV#P
#7
Gn097
151
Interface between CNC and PMC
B-64805EN/03
#7
EKC7
#6
EKC6
#5
EKC5
#4
EKC4
#3
EKC3
#2
EKC2
#1
EKC1
#0
EKC0
#7
#6
#5
#4
#3
#2
#1
#0
#7
+J8#SV
#6
+J7#SV
#5
+J6#SV
#4
+J5#SV
#3
+J4#SV
#2
+J3#SV
#1
+J2#SV
#0
+J1#SV
#7
*+ED28#
#6
*+ED27#
#5
*+ED26#
#4
*+ED25#
#3
*+ED24#
#2
*+ED23#
#1
*+ED22#
#0
*+ED21#
SV
SV
SV
SV
SV
SV
SV
SV
#7
-J8#SV
#6
-J7#SV
#5
-J6#SV
#4
-J5#SV
#3
-J4#SV
#2
-J3#SV
#1
-J2#SV
#0
-J1#SV
#7
*ED28#SV
#6
*ED27#SV
#5
*ED26#SV
#4
*ED25#SV
#3
*ED24#SV
#2
*ED23#SV
#1
*ED22#SV
#0
*ED21#SV
#7
+EXL8#S
#6
+EXL7#S
#5
+EXL6#S
#4
+EXL5#S
#3
+EXL4#S
#2
+EXL3#S
#1
+EXL2#S
#0
+EXL1#S
V
V
V
V
V
V
V
V
Gn105
#7
-EXL8#SV
#6
-EXL7#SV
#5
-EXL6#SV
#4
-EXL5#SV
#3
-EXL4#SV
#2
-EXL3#SV
#1
-EXL2#SV
#0
-EXL1#SV
Gn106
#7
MI8#SV
#6
MI7#SV
#5
MI6#SV
#4
MI5#SV
#3
MI4#SV
#2
MI3#SV
#1
MI2#SV
#0
MI1#SV
#7
*+ED38#
#6
*+ED37#
#5
*+ED36#
#4
*+ED35#
#3
*+ED34#
#2
*+ED33#
#1
*+ED32#
#0
*+ED31#
SV
SV
SV
SV
SV
SV
SV
SV
#7
MLK8#SV
#6
MLK7#SV
#5
MLK6#SV
#4
MLK5#SV
#3
MLK4#SV
#2
MLK3#SV
#1
MLK2#SV
#0
MLK1#SV
#7
*ED38#SV
#6
*ED37#SV
#5
*ED36#SV
#4
*ED35#SV
#3
*ED34#SV
#2
*ED33#SV
#1
*ED32#SV
#0
*ED31#SV
#7
+LM8#SV
#6
+LM7#SV
#5
+LM6#SV
#4
+LM5#SV
#3
+LM4#SV
#2
+LM3#SV
#1
+LM2#SV
#0
+LM1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
-LM8#SV
#6
-LM7#SV
#5
-LM6#SV
#4
-LM5#SV
#3
-LM4#SV
#2
-LM3#SV
#1
-LM2#SV
#0
-LM1#SV
Gn098
Gn099
Gn100
Gn101
Gn102
Gn103
Gn104
Gn107
Gn108
Gn109
Gn110
Gn111
Gn112
152
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
#3
#2
#1
#0
#7
*+L8#SV
#6
*+L7#SV
#5
*+L6#SV
#4
*+L5#SV
#3
*+L4#SV
#2
*+L3#SV
#1
*+L2#SV
#0
*+L1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
*-L8#SV
#6
*-L7#SV
#5
*-L6#SV
#4
*-L5#SV
#3
*-L4#SV
#2
*-L3#SV
#1
*-L2#SV
#0
*-L1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
*+ED8#SV
#6
*+ED7#SV
#5
*+ED6#SV
#4
*+ED5#SV
#3
*+ED4#SV
#2
*+ED3#SV
#1
*+ED2#SV
#0
*+ED1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
*-ED8#SV
#6
*-ED7#SV
#5
*-ED6#SV
#4
*-ED5#SV
#3
*-ED4#SV
#2
*-ED3#SV
#1
*-ED2#SV
#0
*-ED1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
PKESS2
PKESS1
#P
#P
PK8#SV
PK7#SV
PK6#SV
PK5#SV
PK4#SV
PK3#SV
PK2#SV
PK1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
DTCH8#S
#6
DTCH7#S
#5
DTCH6#S
#4
DTCH5#S
#3
DTCH4#S
#2
DTCH3#S
#1
DTCH2#S
#0
DTCH1#S
V
V
V
V
V
V
V
V
#7
IUDD8#S
#6
IUDD7#S
#5
IUDD6#S
#4
IUDD5#S
#3
IUDD4#S
#2
IUDD3#S
#1
IUDD2#S
#0
IUDD1#S
V
V
V
V
V
V
V
V
#7
SVF8#SV
#6
SVF7#SV
#5
SVF6#SV
#4
SVF5#SV
#3
SVF4#SV
#2
SVF3#SV
#1
SVF2#SV
#0
SVF1#SV
#7
#6
#5
#4
#3
#2
#1
#0
Gn113
Gn114
Gn115
Gn116
Gn117
Gn118
Gn119
Gn120
Gn121
Gn122
Gn123
Gn124
Gn125
Gn126
153
Interface between CNC and PMC
B-64805EN/03
Gn127
Gn128
#7
MIX8#SV
#6
MIX7#SV
#5
MIX6#SV
#4
MIX5#SV
#3
MIX4#SV
#2
MIX3#SV
#1
MIX2#SV
#0
MIX1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
*IT8#SV
#6
*IT7#SV
#5
*IT6#SV
#4
*IT5#SV
#3
*IT4#SV
#2
*IT3#SV
#1
*IT2#SV
#0
*IT1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
+MIT8#P
+MIT7#P
+MIT6#P
+MIT5#P
+MIT4#P
+MIT3#P
+MIT2#P
+MIT1#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
-MIT8#P
-MIT7#P
-MIT6#P
-MIT5#P
-MIT4#P
-MIT3#P
-MIT2#P
-MIT1#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
EAX8#SV
#6
EAX7#SV
#5
EAX6#SV
#4
EAX5#SV
#3
EAX4#SV
#2
EAX3#SV
#1
EAX2#SV
#0
EAX1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
SYNC8#S
#6
SYNC7#S
#5
SYNC6#S
#4
SYNC5#S
#3
SYNC4#S
#2
SYNC3#S
#1
SYNC2#S
#0
SYNC1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
#7
SYNCJ8
#6
SYNCJ7
#5
SYNCJ6
#4
SYNCJ5
#3
SYNCJ4
#2
SYNCJ3
#1
SYNCJ2
#0
SYNCJ1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
Gn129
Gn130
Gn131
Gn132
Gn133
Gn134
Gn135
Gn136
Gn137
Gn138
Gn139
Gn140
Gn141
154
B-64805EN/03
Gn142
Gn143
Gn144
Gn145
Gn146
Gn147
Gn148
Gn149
Gn150
Gn151
Interface between CNC and PMC
#7
EBUFA#
#6
ECLRA#
#5
ESTPA#P
#4
ESOFA#
#3
ESBKA#
#2
EMBUF
A#PX
#1
ELCKZA
#0
EFINA#P
PX
PX
X
PX
PX
#PX
X
#7
EMSBK
A#PX
#6
#5
#4
#3
#2
#1
#0
EC6A#PX
EC5A#PX
EC4A#PX
EC3A#PX
EC2A#PX
EC1A#PX
EC0A#PX
#7
EIF7A#PX
#6
EIF6A#PX
#5
EIF5A#PX
#4
EIF4A#PX
#3
EIF3A#PX
#2
EIF2A#PX
#1
EIF1A#PX
#0
EIF0A#PX
#7
EIF15A#P
#6
EIF14A#P
#5
EIF13A#P
#4
EIF12A#P
#3
EIF11A#P
#2
EIF10A#P
#1
#0
X
X
X
X
X
X
EIF9A#PX
EIF8A#PX
#7
EID7A#PX
#6
EID6A#PX
#5
EID5A#PX
#4
EID4A#PX
#3
EID3A#PX
#2
EID2A#PX
#1
EID1A#PX
#0
EID0A#PX
#7
EID15A#
#6
EID14A#
#5
EID13A#
#4
EID12A#
#3
EID11A#
#2
EID10A#
#1
#0
PX
PX
PX
PX
PX
PX
EID9A#PX
EID8A#PX
#7
EID23A#
#6
EID22A#
#5
EID21A#
#4
EID20A#
#3
EID19A#
#2
EID18A#
#1
EID17A#
#0
EID16A#
PX
PX
PX
PX
PX
PX
PX
PX
#7
EID31A#
#6
EID30A#
#5
EID29A#
#4
EID28A#
#3
EID27A#
#2
EID26A#
#1
EID25A#
#0
EID24A#
PX
PX
PX
PX
PX
PX
PX
PX
#7
EDRN#P
#6
ERT#P
#5
EOVC#P
#4
#3
#2
#1
EROV2#P
#0
EROV1#P
#7
*EFOV7#
#6
*EFOV6#
#5
*EFOV5#
#4
*EFOV4#
#3
*EFOV3#
#2
*EFOV2#
#1
*EFOV1#
#0
*EFOV0#
P
P
P
P
P
P
P
P
*EROV7#
*EROV6#
*EROV5#
*EROV4#
*EROV3#
*EROV2#
*EROV1#
*EROV0#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
EBUFB#
#6
ECLRB#
#5
ESTPB#P
#4
ESOFB#
#3
ESBKB#
#1
ELCKZB
#0
EFINB#P
PX
PX
X
PX
PX
#2
EMBUF
B#PX
#PX
X
#7
#6
#5
#4
#3
#2
#1
#0
Gn152
Gn153
Gn154
155
Interface between CNC and PMC
Gn155
Gn156
Gn157
Gn158
Gn159
Gn160
Gn161
EMSBK
B#PX
EC6B#PX
EC5B#PX
EC4B#PX
EC3B#PX
EC2B#PX
EC1B#PX
EC0B#PX
#7
EIF7B#PX
#6
EIF6B#PX
#5
EIF5B#PX
#4
EIF4B#PX
#3
EIF3B#PX
#2
EIF2B#PX
#1
EIF1B#PX
#0
EIF0B#PX
#7
EIF15B#P
#6
EIF14B#P
#5
EIF13B#P
#4
EIF12B#P
#3
EIF11B#P
#2
EIF10B#P
#1
#0
X
X
X
X
X
X
EIF9B#PX
EIF8B#PX
#7
EID7B#PX
#6
EID6B#PX
#5
EID5B#PX
#4
EID4B#PX
#3
EID3B#PX
#2
EID2B#PX
#1
EID1B#PX
#0
EID0B#PX
#7
EID15B#
#6
EID14B#
#5
EID13B#
#4
EID12B#
#3
EID11B#
#2
EID10B#
#1
#0
PX
PX
PX
PX
PX
PX
EID9B#PX
EID8B#PX
#7
EID23B#
#6
EID22B#
#5
EID21B#
#4
EID20B#
#3
EID19B#
#2
EID18B#
#1
EID17B#
#0
EID16B#
PX
PX
PX
PX
PX
PX
PX
PX
#7
EID31B#
#6
EID30B#
#5
EID29B#
#4
EID28B#
#3
EID27B#
#2
EID26B#
#1
EID25B#
#0
EID24B#
PX
PX
PX
PX
PX
PX
PX
PX
#7
#6
#5
EOVCB#
#4
#3
#2
#1
#0
Gn162
Gn163
B-64805EN/03
PX
#7
*EFOV7
B#PX
*EROV7
B#PX
#6
*EFOV6
B#PX
*EROV6
B#PX
#5
*EFOV5
B#PX
*EROV5
B#PX
#4
*EFOV4
B#PX
*EROV4
B#PX
#3
*EFOV3
B#PX
*EROV3
B#PX
#2
*EFOV2
B#PX
*EROV2
B#PX
#1
*EFOV1
B#PX
*EROV1
B#PX
#0
*EFOV0
B#PX
*EROV0
B#PX
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
EBUFC#
#6
ECLRC#
#5
ESTPC#P
#4
ESOFC#
#3
ESBKC#
#1
ELCKZC
#0
EFINC#P
PX
PX
X
PX
PX
#2
EMBUF
C#PX
#PX
X
#7
EMSBK
C#PX
#6
#5
#4
#3
#2
#1
#0
EC6C#PX
EC5C#PX
EC4C#PX
EC3C#PX
EC2C#PX
EC1C#PX
EC0C#PX
#6
EIF6C#PX
#5
EIF5C#PX
#4
EIF4C#PX
#3
EIF3C#PX
#2
EIF2C#PX
#1
EIF1C#PX
#0
EIF0C#PX
Gn164
Gn165
Gn166
Gn167
Gn168
156
#7
EIF7C#PX
B-64805EN/03
Gn169
Gn170
Gn171
Gn172
Gn173
Interface between CNC and PMC
#7
EIF15C#P
#6
EIF14C#P
#5
EIF13C#P
#4
EIF12C#P
#3
EIF11C#P
#2
EIF10C#P
#1
#0
X
X
X
X
X
X
EIF9C#PX
EIF8C#PX
#7
EID7C#PX
#6
EID6C#PX
#5
EID5C#PX
#4
EID4C#PX
#3
EID3C#PX
#2
EID2C#PX
#1
EID1C#PX
#0
EID0C#PX
#7
EID15C#
#6
EID14C#
#5
EID13C#
#4
EID12C#
#3
EID11C#
#2
EID10C#
#1
#0
PX
PX
PX
PX
PX
PX
EID9C#PX
EID8C#PX
#7
EID23C#
#6
EID22C#
#5
EID21C#
#4
EID20C#
#3
EID19C#
#2
EID18C#
#1
EID17C#
#0
EID16C#
PX
PX
PX
PX
PX
PX
PX
PX
#7
EID31C#
#6
EID30C#
#5
EID29C#
#4
EID28C#
#3
EID27C#
#2
EID26C#
#1
EID25C#
#0
EID24C#
PX
PX
PX
PX
PX
PX
PX
PX
#7
#6
#5
EOVCC#
#4
#3
#2
#1
#0
Gn174
Gn175
PX
#7
*EFOV7
C#PX
*EROV7
C#PX
#6
*EFOV6
C#PX
*EROV6
C#PX
#5
*EFOV5
C#PX
*EROV5
C#PX
#4
*EFOV4
C#PX
*EROV4
C#PX
#3
*EFOV3
C#PX
*EROV3
C#PX
#2
*EFOV2
C#PX
*EROV2
C#PX
#1
*EFOV1
C#PX
*EROV1
C#PX
#0
*EFOV0
C#PX
*EROV0
C#PX
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
EBUFD#
#6
ECLRD#
#5
ESTPD#P
#4
ESOFD#
#3
ESBKD#
#1
ELCKZD
#0
EFIND#P
PX
PX
X
PX
PX
#2
EMBUF
D#PX
#PX
X
#7
EMSBK
D#PX
#6
#5
#4
#3
#2
#1
#0
EC6D#PX
EC5D#PX
EC4D#PX
EC3D#PX
EC2D#PX
EC1D#PX
EC0D#PX
#7
EIF7D#PX
#6
EIF6D#PX
#5
EIF5D#PX
#4
EIF4D#PX
#3
EIF3D#PX
#2
EIF2D#PX
#1
EIF1D#PX
#0
EIF0D#PX
#7
EIF15D#P
#6
EIF14D#P
#5
EIF13D#P
#4
EIF12D#P
#3
EIF11D#P
#2
EIF10D#P
#1
#0
X
X
X
X
X
X
EIF9D#PX
EIF8D#PX
Gn176
Gn177
Gn178
Gn179
Gn180
Gn181
157
Interface between CNC and PMC
Gn182
Gn183
Gn184
Gn185
#7
EID7D#PX
#6
EID6D#PX
#5
EID5D#PX
#4
EID4D#PX
#3
EID3D#PX
#2
EID2D#PX
#1
EID1D#PX
#0
EID0D#PX
#7
EID15D#
#6
EID14D#
#5
EID13D#
#4
EID12D#
#3
EID11D#
#2
EID10D#
#1
#0
PX
PX
PX
PX
PX
PX
EID9D#PX
EID8D#PX
#7
EID23D#
#6
EID22D#
#5
EID21D#
#4
EID20D#
#3
EID19D#
#2
EID18D#
#1
EID17D#
#0
EID16D#
PX
PX
PX
PX
PX
PX
PX
PX
#7
EID31D#
#6
EID30D#
#5
EID29D#
#4
EID28D#
#3
EID27D#
#2
EID26D#
#1
EID25D#
#0
EID24D#
PX
PX
PX
PX
PX
PX
PX
PX
#7
#6
#5
EOVCD#
#4
#3
#2
#1
#0
Gn186
Gn187
B-64805EN/03
PX
#7
*EFOV7
D#PX
*EROV7
D#PX
#6
*EFOV6
D#PX
*EROV6
D#PX
#5
*EFOV5
D#PX
*EROV5
D#PX
#4
*EFOV4
D#PX
*EROV4
D#PX
#3
*EFOV3
D#PX
*EROV3
D#PX
#2
*EFOV2
D#PX
*EROV2
D#PX
#1
*EFOV1
D#PX
*EROV1
D#PX
#0
*EFOV0
D#PX
*EROV0
D#PX
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
OVLS8#S
#6
OVLS7#S
#5
OVLS6#S
#4
OVLS5#S
#3
OVLS4#S
#2
OVLS3#S
#1
OVLS2#S
#0
OVLS1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
#7
IGVRY8#
#6
IGVRY7#
#5
IGVRY6#
#4
IGVRY5#
#3
IGVRY4#
#2
IGVRY3#
#1
IGVRY2#
#0
IGVRY1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
#6
#5
#4
#3
HDSR#P
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Gn188
Gn189
Gn190
Gn191
Gn192
Gn193
Gn194
Gn195
158
B-64805EN/03
Gn196
Interface between CNC and PMC
#7
*DEC8#S
#6
*DEC7#S
#5
*DEC6#S
#4
*DEC5#S
#3
*DEC4#S
#2
*DEC3#S
#1
*DEC2#S
#0
*DEC1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
MTD#P
#2
MTC#P
#1
MTB#P
#0
MTA#P
#7
NPOS8#S
#6
NPOS7#S
#5
NPOS6#S
#4
NPOS5#S
#3
NPOS4#S
#2
NPOS3#S
#1
NPOS2#S
#0
NPOS1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
IOLBH2
#0
IOLBH1
#7
#6
#5
#4
#3
#2
#1
#0
#7
RSTRT#P
#6
#5
#4
#3
#2
#1
#0
#7
NDCAL8
#6
NDCAL7
#5
NDCAL6
#4
NDCAL5
#3
NDCAL4
#2
NDCAL3
#1
NDCAL2
#0
NDCAL1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#3
#2
#1
PWFL
AOFS2#P
AOFS1#P
#4
CHGAO#
ESTPR#P
FTCLR#P
FTCAL#P
#0
FTCMD#
#7
MRDYC#
#6
ORCMC#
#5
#4
#1
TLMHC#
#0
TLMLC#S
SP
SRVC#SP
#2
CTH2C#S
SP
SFRC#SP
#3
CTH1C#S
P
P
SP
P
#7
#6
RCHC#SP
RSLC#SP
#5
INTGC#S
#4
SOCNC#
#3
MCFNC#
#2
SPSLC#S
#1
*ESPC#S
#0
ARSTC#
P
SP
SP
P
P
SP
#7
RCHHG
C#SP
#6
MFNHG
C#SP
#5
INCMDC
#4
OVRC#SP
#2
NRROC#
#1
ROTAC#
#0
INDXC#S
#SP
#3
DEFMD
C#SP
SP
SP
P
#7
#6
#5
#4
#3
#1
DSCNC
SORSLC
#2
MPOFC#
#0
MORCM
C#SP
Gn197
Gn198
Gn199
Gn200
Gn201
Gn202
Gn203
Gn204
Gn205
Gn206
Gn207
Gn208
P
SP
SLVC#SP
P
#7
SH07C#S
#6
SH06C#S
#5
SH05C#S
#4
SH04C#S
#3
SH03C#S
#2
SH02C#S
#1
SH01C#S
#0
SH00C#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
159
Interface between CNC and PMC
Gn209
B-64805EN/03
SH14C#S
SH13C#S
SH12C#S
SH11C#S
SH10C#S
SH09C#S
SH08C#S
P
P
P
P
P
P
P
Gn210
#7
ED23#P
#6
ED22#P
#5
ED21#P
#4
ED20#P
#3
ED19#P
#2
ED18#P
#1
ED17#P
#0
ED16#P
Gn211
#7
ED31#P
#6
ED30#P
#5
ED29#P
#4
ED28#P
#3
ED27#P
#2
ED26#P
#1
ED25#P
#0
ED24#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
*CGROV
7#P
#6
*CGROV
6#P
#5
*CGROV
5#P
#4
*CGROV
4#P
#3
*CGROV
3#P
#2
*CGROV
2#P
#1
*CGROV
1#P
#0
*CGROV
0#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
ESSYC4
#2
ESSYC3
#1
ESSYC2
#0
ESSYC1
#SP
#SP
#SP
#SP
#3
PKESE4
#2
PKESE3
#1
PKESE2
#0
PKESE1
#SP
#SP
#SP
#SP
#3
CTH1D#S
#2
CTH2D#S
#1
TLMHD#
#0
TLMLD#S
P
P
SP
P
Gn212
Gn213
Gn214
Gn215
Gn216
Gn217
Gn220
Gn251
Gn263
Gn264
#7
#6
#5
#4
Gn265
Gn266
160
#7
MRDYD#
#6
ORCMD#
SP
SP
#5
#4
SFRD#SP
SRVD#SP
B-64805EN/03
Gn267
Gn268
Interface between CNC and PMC
#7
#6
#5
INTGD#S
#4
SOCND#
#3
MCFND#
#2
SPSLD#S
#1
*ESPD#S
#0
ARSTD#
RCHD#SP
RSLD#SP
P
SP
SP
P
P
SP
#7
RCHHG
D#SP
#6
MFNHG
D#SP
#5
INCMDD
#4
OVRD#SP
#2
NRROD#
#1
ROTAD#
#0
INDXD#S
#SP
#3
DEFMD
D#SP
SP
SP
P
#7
#6
#5
#4
#3
#1
DSCND
SORSLD
#2
MPOFD#
#0
MORCM
D#SP
Gn269
Gn270
SP
SLVD#SP
#7
SH07D#S
#6
SH06D#S
#5
SH05D#S
#4
SH04D#S
#3
SH03D#S
#2
SH02D#S
#1
SH01D#S
#0
SH00D#S
P
P
P
P
P
P
P
P
#7
#6
SH14D#S
#5
SH13D#S
#4
SH12D#S
#3
SH11D#S
#2
SH10D#S
#1
SH09D#S
#0
SH08D#S
P
P
P
P
P
P
P
Gn271
Gn272
#7
R08I4#SP
#6
R07I4#SP
#5
R06I4#SP
#4
R05I4#SP
#3
R04I4#SP
#2
R03I4#SP
#1
R02I4#SP
#0
R01I4#SP
#6
SSIN4#SP
#5
SGN4#SP
#4
Gn273
#7
SIND4#SP
#3
R12I4#SP
#2
R11I4#SP
#1
R10I4#SP
#0
R09I4#SP
#7
#6
#5
#4
CSFI4#SP
CSFI3#SP
CSFI2#SP
CSFI1#SP
#3
CONS4#
#2
CONS3#
#1
CONS2#
#0
CONS1#
SP
SP
SP
SP
#7
#6
#5
#4
#3
#2
#1
#0
Gn276
#7
UI107#P
#6
UI106#P
#5
UI105#P
#4
UI104#P
#3
UI103#P
#2
UI102#P
#1
UI101#P
#0
UI100#P
Gn277
#7
UI115#P
#6
UI114#P
#5
UI113#P
#4
UI112#P
#3
UI111#P
#2
UI110#P
#1
UI109#P
#0
UI108#P
Gn278
#7
UI123#P
#6
UI122#P
#5
UI121#P
#4
UI120#P
#3
UI119#P
#2
UI118#P
#1
UI117#P
#0
UI116#P
Gn279
#7
UI131#P
#6
UI130#P
#5
UI129#P
#4
UI128#P
#3
UI127#P
#2
UI126#P
#1
UI125#P
#0
UI124#P
Gn280
#7
UI207#P
#6
UI206#P
#5
UI205#P
#4
UI204#P
#3
UI203#P
#2
UI202#P
#1
UI201#P
#0
UI200#P
#7
#6
#5
#4
#3
#2
#1
#0
Gn274
Gn275
161
Interface between CNC and PMC
B-64805EN/03
Gn281
UI215#P
UI214#P
UI213#P
UI212#P
UI211#P
UI210#P
UI209#P
UI208#P
Gn282
#7
UI223#P
#6
UI222#P
#5
UI221#P
#4
UI220#P
#3
UI219#P
#2
UI218#P
#1
UI217#P
#0
UI216#P
Gn283
#7
UI231#P
#6
UI230#P
#5
UI229#P
#4
UI228#P
#3
UI227#P
#2
UI226#P
#1
UI225#P
#0
UI224#P
Gn284
#7
UI307#P
#6
UI306#P
#5
UI305#P
#4
UI304#P
#3
UI303#P
#2
UI302#P
#1
UI301#P
#0
UI300#P
Gn285
#7
UI315#P
#6
UI314#P
#5
UI313#P
#4
UI312#P
#3
UI311#P
#2
UI310#P
#1
UI309#P
#0
UI308#P
Gn286
#7
UI323#P
#6
UI322#P
#5
UI321#P
#4
UI320#P
#3
UI319#P
#2
UI318#P
#1
UI317#P
#0
UI316#P
Gn287
#7
UI331#P
#6
UI330#P
#5
UI329#P
#4
UI328#P
#3
UI327#P
#2
UI326#P
#1
UI325#P
#0
UI324#P
#7
#6
#5
#4
#3
SPSYC4
#2
SPSYC3
#1
SPSYC2
#0
SPSYC1
#SP
#SP
#SP
#SP
#3
SPPHS4
#2
SPPHS3
#1
SPPHS2
#0
SPPHS1
#SP
#SP
#SP
#SP
Gn288
#7
#6
#5
#4
Gn289
#7
IMMD#P
#6
#5
PGCK#P
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
ITCD
#6
ITCD3
#5
ITCD2
#4
ITCD1
#3
ITRC
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
CNCKY
#6
C2SEND
#5
#4
#3
#2
#1
#0
Gn295
Gn296
#7
DI8#SV
#6
DI7#SV
#5
DI6#SV
#4
DI5#SV
#3
DI4#SV
#2
DI3#SV
#1
DI2#SV
#0
DI1#SV
Gn290
Gn291
Gn292
Gn293
Gn294
162
B-64805EN/03
Interface between CNC and PMC
#7
Gn297
#7
#6
#5
AOFS2#P
AOFS1#P
#6
#5
#4
CHGAO#
#3
#2
#1
BCAN#P
P
#4
#0
#3
#2
#1
#0
TB_BAS
E#P
RNDH#P
Gn298
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
INESTR
A
#5
#4
#3
CSYCA#
#2
#1
#0
#7
#6
#5
#4
#3
HF4A
#2
HF3A
#1
HF2A
#0
HF1A
#7
#6
#5
#4
#3
#2
TDFCAN
A
#1
PWMSE
A
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
INESTR
B
#5
#4
#3
CSYCB#
#2
#1
#0
#7
#6
#5
#4
#3
HF4B
#2
HF3B
#1
HF2B
#0
HF1B
#7
#6
#5
#4
#3
#2
TDFCAN
B
#1
PWMSE
B
#0
#7
#6
#5
#4
#3
#2
#1
#0
Gn299
Gn300
Gn301
Gn302
Gn303
Gn304
FRFSMA
SP
Gn305
Gn306
Gn307
Gn308
FRFSMB
SP
Gn309
Gn310
163
Interface between CNC and PMC
B-64805EN/03
Gn311
#7
Gn312
#6
INESTR
C
#5
#2
#1
#0
#7
#6
#5
#4
#3
HF4C
#2
HF3C
#1
HF2C
#0
HF1C
#7
#6
#5
#4
#3
#2
TDFCAN
C
#1
PWMSE
C
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
INESTR
D
#5
#4
#3
CSYCD#
#2
#1
#0
#7
#6
#5
#4
#3
HF4D
#2
HF3D
#1
HF2D
#0
HF1D
#7
#6
#5
#4
#3
#2
TDFCAN
D
#1
PWMSE
D
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
FRFSMC
#4
#3
CSYCC#
SP
Gn313
Gn314
Gn315
Gn316
FRFSMD
SP
Gn317
Gn318
Gn319
Gn320
Gn321
Gn322
Gn323
Gn324
Gn325
164
B-64805EN/03
Interface between CNC and PMC
Gn326
#7
#6
#5
#4
#3
#2
#1
#0
#7
TLRSTI4
#6
TLRSTI3
#5
TLRSTI2
#4
TLRSTI1
#3
TLRST4#
#2
TLRST3#
#1
TLRST2#
#0
TLRST1#
#P
#P
#P
#P
P
P
P
P
#7
TLNCT4#
#6
TLNCT3#
#5
TLNCT2#
#4
TLNCT1#
#3
TLSKP4#
#2
TLSKP3#
#1
TLSKP2#
#0
TLSKP1#
P
P
P
P
P
P
P
P
#7
#6
#5
TKEY5
#4
TKEY4
#3
TKEY3
#2
TKEY2
#1
TKEY1
#0
TKEY0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
SLRER#P
#5
SLREF#P
#4
#3
#2
#1
#0
#7
*+ED48#
#6
*+ED47#
#5
*+ED46#
#4
*+ED45#
#3
*+ED44#
#2
*+ED43#
#1
*+ED42#
#0
*+ED41#
SV
SV
SV
SV
SV
SV
SV
SV
Gn327
Gn328
Gn329
Gn330
Gn331
Gn332
Gn333
Gn334
Gn335
Gn336
Gn337
Gn338
Gn339
Gn340
Gn341
165
Interface between CNC and PMC
Gn342
Gn343
Gn344
B-64805EN/03
#7
*ED48#SV
#6
*ED47#SV
#5
*ED46#SV
#4
*ED45#SV
#3
*ED44#SV
#2
*ED43#SV
#1
*ED42#SV
#0
*ED41#SV
#7
*+ED58#
#6
*+ED57#
#5
*+ED56#
#4
*+ED55#
#3
*+ED54#
#2
*+ED53#
#1
*+ED52#
#0
*+ED51#
SV
SV
SV
SV
SV
SV
SV
SV
#7
*ED58#SV
#6
*ED57#SV
#5
*ED56#SV
#4
*ED55#SV
#3
*ED54#SV
#2
*ED53#SV
#1
*ED52#SV
#0
*ED51#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
NOT3DM
#6
#5
#4
#3
#2
#1
#0
Gn345
Gn346
Gn347
HDN#P
#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
SSEGB4
#2
SSEGB3
#1
SSEGB2
#0
SSEGB1
#SP
#SP
#SP
#SP
Gn348
Gn349
Gn350
Gn351
Gn352
Gn353
166
#7
*FHRO7#
#6
*FHRO6#
#5
*FHRO5#
#4
*FHRO4#
#3
*FHRO3#
#2
*FHRO2#
#1
*FHRO1#
#0
*FHRO0#
P
P
P
P
P
P
P
P
#7
FHROV#
#6
#5
#4
#3
#2
#1
*FHRO9#
#0
*FHRO8#
P
P
P
Gn354
#7
THD07#P
#6
THD06#P
#5
THD05#P
#4
THD04#P
#3
THD03#P
#2
THD02#P
#1
THD01#P
#0
THD00#P
Gn355
#7
THD15#P
#6
THD14#P
#5
THD13#P
#4
THD12#P
#3
THD11#P
#2
THD10#P
#1
THD09#P
#0
THD08#P
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
#3
#2
#1
THSTB#P
#0
THML#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
WPRST8
#6
WPRST7
#5
WPRST6
#4
WPRST5
#3
WPRST4
#2
WPRST3
#1
WPRST2
#0
WPRST1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
Gn376
#7
SOV27#P
#6
SOV26#P
#5
SOV25#P
#4
SOV24#P
#3
SOV23#P
#2
SOV22#P
#1
SOV21#P
#0
SOV20#P
Gn377
#7
SOV37#P
#6
SOV36#P
#5
SOV35#P
#4
SOV34#P
#3
SOV33#P
#2
SOV32#P
#1
SOV31#P
#0
SOV30#P
Gn378
#7
SOV47#P
#6
SOV46#P
#5
SOV45#P
#4
SOV44#P
#3
SOV43#P
#2
SOV42#P
#1
SOV41#P
#0
SOV40#P
Gn379
#7
HS5ID#P
#6
HS5IC#P
#5
HS5IB#P
#4
HS5IA#P
#3
HS5D#P
#2
HS5C#P
#1
HS5B#P
#0
HS5A#P
#7
#6
#5
#4
#3
#2
#1
MP52#P
#0
MP51#P
#7
#6
#5
#4
#3
AUTPHD
#2
AUTPHC
#1
AUTPHB
#0
AUTPHA
#P
#P
#P
#P
Gn356
Gn357
Gn358
Gn375
Gn380
Gn381
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Gn382
Gn383
Gn384
Gn385
Gn386
167
Interface between CNC and PMC
B-64805EN/03
Gn387
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
*SUCPF
D#SP
#2
*SUCPF
C#SP
#1
*SUCPF
B#SP
#0
#7
#6
#5
#4
#3
*SCPFD#
#2
*SCPFC#
#1
*SCPFB#
#0
SP
SP
SP
#3
SPSTPD
#2
SPSTPC
#1
SPSTPB
#SP
#SP
#SP
Gn388
Gn389
Gn390
Gn391
Gn392
Gn393
Gn394
Gn395
Gn396
Gn397
Gn398
Gn399
Gn400
Gn401
#7
Gn402
168
#6
#5
#4
#0
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
SLPCD#P
#4
SLPCC#P
#3
#2
#1
SLSPD#P
#0
SLSPC#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
ITF08#P
ITF07#P
ITF06#P
ITF05#P
ITF04#P
ITF03#P
ITF02#P
ITF01#P
#7
#6
#5
#4
#3
#2
#1
#0
ITCD6
ITCD5
ITCD4
ITF10#P
ITF09#P
#4
#3
#2
#1
MDISL
HEAD4
HEAD3
#0
STCHK#
Gn403
Gn404
Gn405
Gn406
Gn407
#7
#6
#5
Gn408
P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
HS4IE#P
#6
HS3IE#P
#5
HS2IE#P
#4
HS1IE#P
#3
HS4E#P
#2
HS3E#S
#1
HS2E#P
#0
HS1E#P
#7
#6
#5
#4
HS5IE#P
#3
#2
#1
#0
HS5E#P
#7
MCST8#P
#6
MCST7#P
#5
MCST6#P
#4
MCST5#P
#3
MCST4#P
#2
MCST3#P
#1
MCST2#P
#0
MCST1#P
#7
MCST16
#6
MCST15
#5
MCST14
#4
MCST13
#3
MCST12
#2
MCST11
#1
MCST10
#0
#P
#P
#P
#P
#P
#P
#P
MCST9#P
#7
#6
#5
#4
HPMRS
V
#3
#2
#1
#0
Gn409
Gn410
Gn411
Gn412
Gn512
Gn513
Gn514
Gn515
MCFIN#P
#7
#6
#5
#4
#3
#2
#1
#0
PPK8#SV
PPK7#SV
PPK6#SV
PPK5#SV
PPK4#SV
PPK3#SV
PPK2#SV
PPK1#SV
169
Interface between CNC and PMC
Gn516
Gn517
B-64805EN/03
#7
SEMI8#S
#6
SEMI7#S
#5
SEMI6#S
#4
SEMI5#S
#3
SEMI4#S
#2
SEMI3#S
#1
SEMI2#S
#0
SEMI1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
GAE2#P
GAE1#P
SYPST#P
GAE3#P
QRSTD#
P
#7
#6
#5
#4
DNTCLR
#3
TDISD
#2
#1
#0
BOV#P
#7
#6
#5
#4
#3
#2
#1
#0
TDICHG
TDID
Gn518
TSE#P
Gn519
Gn522
Gn523
P
#7
#6
PTOV7
#5
PTOV6
#4
PTOV5
#3
PTOV4
#2
PTOV3
#1
PTOV2
#0
PTOV1
#7
SRVON8
#6
SRVON7
#5
SRVON6
#4
SRVON5
#3
SRVON4
#2
SRVON3
#1
SRVON2
#0
SRVON1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
PTSK8#P
#6
PTSK7#P
#5
PTSK6#P
#4
PTSK5#P
#3
PTSK4#P
#2
PTSK3#P
#1
PTSK2#P
#0
PTSK1#P
#7
SVRVS8
#6
SVRVS7
#5
SVRVS6
#4
SVRVS5
#3
SVRVS4
#2
SVRVS3
#1
SVRVS2
#0
SVRVS1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
MT8N07#
MT8N06#
MT8N05#
MT8N04#
MT8N03#
MT8N02#
MT8N01#
MT8N00#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
MT8N15#
MT8N14#
MT8N13#
MT8N12#
MT8N11#
MT8N10#
MT8N09#
MT8N08#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
MT8N23#
MT8N22#
MT8N21#
MT8N20#
MT8N19#
MT8N18#
MT8N17#
MT8N16#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
Gn520
Gn521
PTREQ#
Gn524
Gn525
Gn526
Gn527
170
B-64805EN/03
Gn528
Interface between CNC and PMC
MT8N31#
MT8N30#
MT8N29#
MT8N28#
MT8N27#
MT8N26#
MT8N25#
MT8N24#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
#7
EGBS8#S
#6
EGBS7#S
#5
EGBS6#S
#4
EGBS5#S
#3
EGBS4#S
#2
EGBS3#S
#1
EGBS2#S
#0
EGBS1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#2
#1
EXLM3#P
EXLM2#P
#3
HBTRN#
P
TCHG
MRVM#P
#0
FWSTP#
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
SSRS#P
#3
SSR4#SP
#2
SSR3#SP
#1
SSR2#SP
#0
SSR1#SP
#7
TDISAW
#6
#5
#4
#3
#2
AXC4#P
#1
AXC2#P
#0
AXC1#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#1
#0
DASN
EXCST#P
ASNST#P
#2
RMVST#
#5
#4
MHLC5#
#3
MHLC4#
#2
MHLC3#
#1
MHLC2#
#0
MHLC1#
P
P
P
P
P
#4
#3
#2
#1
#0
MHUS5#
MHUS4#
MHUS3#
MHUS2#
MHUS1#
P
P
P
P
P
#5
#4
#3
#2
#1
#0
OFNC5#P
OFNC4#P
OFNC3#P
OFNC2#P
OFNC1#P
OFNC0#P
#5
#4
Gn529
Gn530
Gn531
OVLN#P
P
Gn532
Gn533
Gn534
Gn535
Gn536
SPSP#P
#7
#6
Gn544
#7
#6
#5
Gn545
#7
GQSMC#
Gn546
#6
P
#7
Gn547
#6
P
#3
#2
#1
#0
OFNC9#P
OFNC8#P
OFNC7#P
OFNC6#P
#3
#2
#1
#0
ONSC#P
#7
#6
#5
#4
171
Interface between CNC and PMC
Gn548
*CL8#SV
*CL7#SV
*CL6#SV
*CL5#SV
*CL4#SV
*CL3#SV
*CL2#SV
*CL1#SV
#7
#6
#5
ASTC#P
RMTC#P
#4
GTMSR#
#3
CONH4#
#2
CONH3#
#1
CONH2#
#0
CONH1#
P
SP
SP
SP
SP
#7
#6
#5
#4
#3
#2
#1
#0
*KAV7#P
*KAV6#P
*KAV5#P
*KAV4#P
*KAV3#P
*KAV2#P
*KAV1#P
*KAV0#P
Gn549
Gn570
Gn571
Gn572
#7
#6
#5
#4
#3
#2
#1
#0
*KBV7#P
*KBV6#P
*KBV5#P
*KBV4#P
*KBV3#P
*KBV2#P
*KBV1#P
*KBV0#P
#7
#6
#5
#4
#3
#2
#1
#0
*KCV7#P
*KCV6#P
*KCV5#P
*KCV4#P
*KCV3#P
*KCV2#P
*KCV1#P
*KCV0#P
#7
#6
#5
#4
#3
#2
#1
#0
*KDV7#P
*KDV6#P
*KDV5#P
*KDV4#P
*KDV3#P
*KDV2#P
*KDV1#P
*KDV0#P
Gn574
#7
P1SI8#P
#6
P1SI7#P
#5
P1SI6#P
#4
P1SI5#P
#3
P1SI4#P
#2
P1SI3#P
#1
P1SI2#P
#0
P1SI1#P
Gn575
#7
P1SI16#P
#6
P1SI15#P
#5
P1SI14#P
#4
P1SI13#P
#3
P1SI12#P
#2
P1SI11#P
#1
P1SI10#P
#0
P1SI9#P
Gn576
#7
P2SI8#P
#6
P2SI7#P
#5
P2SI6#P
#4
P2SI5#P
#3
P2SI4#P
#2
P2SI3#P
#1
P2SI2#P
#0
P2SI1#P
Gn577
#7
P2SI16#P
#6
P2SI15#P
#5
P2SI14#P
#4
P2SI13#P
#3
P2SI12#P
#2
P2SI11#P
#1
P2SI10#P
#0
P2SI9#P
#7
PSIM#P
#6
#5
#4
#3
#2
Gn578
#1
PSI2#P
#0
PSI1#P
#7
#6
NHSW
#5
WBEND
#4
#3
#2
#1
#0
TDRCOF
#7
*ACTF8#
#6
*ACTF7#
#5
*ACTF6#
#4
*ACTF5#
#3
*ACTF4#
#2
*ACTF3#
#1
*ACTF2#
#0
*ACTF1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
SLANG
#6
LANG7
#5
LANG6
#4
LANG5
#3
LANG4
#2
LANG3
#1
LANG2
#0
LANG1
Gn573
Gn579
Gn580
Gn581
172
B-64805EN/03
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
#3
#2
#1
Gn582
#0
EADCJA
#PX
#7
#6
#5
#4
#3
#2
#1
Gn583
#0
EADCJB
#PX
#7
#6
#5
#4
#3
#2
#1
Gn584
#0
EADCJC
#PX
#7
#6
#5
#4
#3
#2
#1
Gn585
#0
EADCJD
#PX
#7
MDOFF4
#6
MDOFF3
#5
MDOFF2
#4
MDOFF1
#3
#2
#1
#0
#SP
#SP
#SP
#SP
Gn587
#7
SPAPH4
#6
SPAPH3
#5
SPAPH2
#4
SPAPH1
#3
SPMST4
#2
SPMST3
#1
SPMST2
#0
SPMST1
Gn588
#7
SMSL24
#6
SMSL23
#5
SMSL22
#4
SMSL21
#3
SMSL14
#2
SMSL13
#1
SMSL12
#0
SMSL11
#7
#6
#5
#4
HSST
#3
#2
#1
#0
#7
#6
TDIOLC
#5
#4
#3
#2
#1
#0
Gn594
#7
OTD7#P
#6
OTD6#P
#5
OTD5#P
#4
OTD4#P
#3
OTD3#P
#2
OTD2#P
#1
OTD1#P
#0
OTD0#P
Gn595
#7
OTD15#P
#6
OTD14#P
#5
OTD13#P
#4
OTD12#P
#3
OTD11#P
#2
OTD10#P
#1
OTD9#P
#0
OTD8#P
Gn596
#7
OTA8
#6
OTA7
#5
OTA6
#4
OTA5
#3
OTA4
#2
OTA3
#1
OTA2
#0
OTA1
Gn597
#7
-OT3#P
#6
+OT3#P
#5
-OT2#P
#4
+OT2#P
#3
-OT12#P
#2
+OT12#P
#1
-OT11#P
#0
+OT11#P
#7
#6
#5
#4
Gn598
-OT3C#P
+OT3C#P
-OT2C#P
+OT2C#P
#3
OT12C#P
#2
+OT12C#
#1
OT11C#P
#0
+OT11C#
#6
RTC2#P
#5
CTC3#P
#4
CTC2#P
#3
GIS#P
#2
#1
Gn599
#7
RTC3#P
#0
OTSW#P
Gn586
Gn589
Gn592
P
P
173
Interface between CNC and PMC
#7
SVMWC
8#SV
#6
SVMWC
7#SV
#5
SVMWC
6#SV
#4
SVMWC
5#SV
#3
SVMWC
4#SV
#2
SVMWC
3#SV
#1
SVMWC
2#SV
#0
SVMWC
1#SV
Gn708
#7
RE08I#SP
#6
RE07I#SP
#5
RE06I#SP
#4
RE05I#SP
#3
RE04I#SP
#2
RE03I#SP
#1
RE02I#SP
#0
RE01I#SP
Gn709
#7
RE16I#SP
#6
RE15I#SP
#5
RE14I#SP
#4
RE13I#SP
#3
RE12I#SP
#2
RE11I#SP
#1
RE10I#SP
#0
RE09I#SP
Gn710
#7
RE24I#SP
#6
RE23I#SP
#5
RE22I#SP
#4
RE21I#SP
#3
RE20I#SP
#2
RE19I#SP
#1
RE18I#SP
#0
RE17I#SP
Gn711
#7
RE32I#SP
#6
RE31I#SP
#5
RE30I#SP
#4
RE29I#SP
#3
RE28I#SP
#2
RE27I#SP
#1
RE26I#SP
#0
RE25I#SP
#7
RE08I2#S
#6
RE07I2#S
#5
RE06I2#S
#4
RE05I2#S
#3
RE04I2#S
#2
RE03I2#S
#1
RE02I2#S
#0
RE01I2#S
P
P
P
P
P
P
P
P
#7
RE16I2#S
#6
RE15I2#S
#5
RE14I2#S
#4
RE13I2#S
#3
RE12I2#S
#2
RE11I2#S
#1
RE10I2#S
#0
RE09I2#S
P
P
P
P
P
P
P
P
#7
RE24I2#S
#6
RE23I2#S
#5
RE22I2#S
#4
RE21I2#S
#3
RE20I2#S
#2
RE19I2#S
#1
RE18I2#S
#0
RE17I2#S
P
P
P
P
P
P
P
P
#7
RE32I2#S
#6
RE31I2#S
#5
RE30I2#S
#4
RE29I2#S
#3
RE28I2#S
#2
RE27I2#S
#1
RE26I2#S
#0
RE25I2#S
P
P
P
P
P
P
P
P
#7
RE08I3#S
#6
RE07I3#S
#5
RE06I3#S
#4
RE05I3#S
#3
RE04I3#S
#2
RE03I3#S
#1
RE02I3#S
#0
RE01I3#S
P
P
P
P
P
P
P
P
#7
RE16I3#S
#6
RE15I3#S
#5
RE14I3#S
#4
RE13I3#S
#3
RE12I3#S
#2
RE11I3#S
#1
RE10I3#S
#0
RE09I3#S
P
P
P
P
P
P
P
P
#7
RE24I3#S
#6
RE23I3#S
#5
RE22I3#S
#4
RE21I3#S
#3
RE20I3#S
#2
RE19I3#S
#1
RE18I3#S
#0
RE17I3#S
P
P
P
P
P
P
P
P
#7
RE32I3#S
#6
RE31I3#S
#5
RE30I3#S
#4
RE29I3#S
#3
RE28I3#S
#2
RE27I3#S
#1
RE26I3#S
#0
RE25I3#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
Gn687
Gn712
Gn713
Gn714
Gn715
Gn716
Gn717
Gn718
Gn719
174
B-64805EN/03
B-64805EN/03
Interface between CNC and PMC
RE08I4#S
RE07I4#S
RE06I4#S
RE05I4#S
RE04I4#S
RE03I4#S
RE02I4#S
RE01I4#S
P
P
P
P
P
P
P
P
#7
RE16I4#S
#6
RE15I4#S
#5
RE14I4#S
#4
RE13I4#S
#3
RE12I4#S
#2
RE11I4#S
#1
RE10I4#S
#0
RE09I4#S
P
P
P
P
P
P
P
P
#7
RE24I4#S
#6
RE23I4#S
#5
RE22I4#S
#4
RE21I4#S
#3
RE20I4#S
#2
RE19I4#S
#1
RE18I4#S
#0
RE17I4#S
P
P
P
P
P
P
P
P
#7
RE32I4#S
#6
RE31I4#S
#5
RE30I4#S
#4
RE29I4#S
#3
RE28I4#S
#2
RE27I4#S
#1
RE26I4#S
#0
RE25I4#S
P
P
P
P
P
P
P
P
#7
KPRS8#S
#6
KPRS7#S
#5
KPRS6#S
#4
KPRS5#S
#3
KPRS4#S
#2
KPRS3#S
#1
KPRS2#S
#0
KPRS1#S
V
V
V
V
V
V
V
V
Gn726
#7
TDC8#SV
#6
TDC7#SV
#5
TDC6#SV
#4
TDC5#SV
#3
TDC4#SV
#2
TDC3#SV
#1
TDC2#SV
#0
TDC1#SV
Gn765
#7
TPMG07
#6
TPMG06
#5
TPMG05
#4
TPMG04
#3
TPMG03
#2
TPMG02
#1
TPMG01
#0
TPMG00
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Gn720
Gn721
Gn722
Gn723
Gn724
Gn766
Gn767
1.3.3.
Signals from CNC to PMC
#7
OP#P
#6
SA#P
#5
STL#P
#4
SPL#P
#3
#2
#1
Fn000
#0
RWD#P
#7
MA#P
#6
Fn001
#5
TAP#P
#4
ENB#SP
#3
DEN#P
#2
BAL#P
#1
RST#P
#0
AL#P
#7
#6
#5
#2
#1
#0
CUT#P
#4
SRNMV#
#3
MDRN#P
P
THRD#P
CSS#P
RPDO#P
INCH#P
#7
#6
MEDT#P
#5
MMEM#P
#4
MRMT#P
#3
MMDI#P
#2
MJ#P
#1
MH#P
#0
MINC#P
#7
#6
#5
#4
#3
#1
MREF#P
MAFL#P
MSBK#P
#2
MABSM#
#0
MBDT1#
Fn002
Fn003
Fn004
P
MMLK#P
P
175
Interface between CNC and PMC
Fn005
B-64805EN/03
#7
MBDT9#
#6
MBDT8#
#5
MBDT7#
#4
MBDT6#
#3
MBDT5#
#2
MBDT4#
#1
MBDT3#
#0
MBDT2#
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
MDIRST#
#0
ERTVA#P
Fn006
P
TPPRS
#6
#5
#4
#3
TF#P
#2
SF#P
#1
Fn007
#7
BF#P
#0
MF#P
#7
MF5#P
#6
MF4#P
#5
MF3#P
#4
MF2#P
#3
#2
#1
#0
Fn008
#7
DM00#P
#6
DM01#P
#5
DM02#P
#4
DM30#P
#3
#2
#1
#0
Fn009
Fn010
#7
M07#P
#6
M06#P
#5
M05#P
#4
M04#P
#3
M03#P
#2
M02#P
#1
M01#P
#0
M00#P
Fn011
#7
M15#P
#6
M14#P
#5
M13#P
#4
M12#P
#3
M11#P
#2
M10#P
#1
M09#P
#0
M08#P
Fn012
#7
M23#P
#6
M22#P
#5
M21#P
#4
M20#P
#3
M19#P
#2
M18#P
#1
M17#P
#0
M16#P
Fn013
#7
M31#P
#6
M30#P
#5
M29#P
#4
M28#P
#3
M27#P
#2
M26#P
#1
M25#P
#0
M24#P
Fn014
#7
M207#P
#6
M206#P
#5
M205#P
#4
M204#P
#3
M203#P
#2
M202#P
#1
M201#P
#0
M200#P
Fn015
#7
M215#P
#6
M214#P
#5
M213#P
#4
M212#P
#3
M211#P
#2
M210#P
#1
M209#P
#0
M208#P
#7
M307#P
M223#P
#6
M306#P
M222#P
#5
M305#P
M221#P
#4
M304#P
M220#P
#3
M303#P
M219#P
#2
M302#P
M218#P
#1
M301#P
M217#P
#0
M300#P
M216#P
#7
M315#P
M231#P
#6
M314#P
M230#P
#5
M313#P
M229#P
#4
M312#P
M228#P
#3
M311#P
M227#P
#2
M310#P
M226#P
#1
M309#P
M225#P
#0
M308#P
M224#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn016
Fn017
Fn018
Fn019
176
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn022
#7
S07#P
#6
S06#P
#5
S05#P
#4
S04#P
#3
S03#P
#2
S02#P
#1
S01#P
#0
S00#P
Fn023
#7
S15#P
#6
S14#P
#5
S13#P
#4
S12#P
#3
S11#P
#2
S10#P
#1
S09#P
#0
S08#P
Fn024
#7
S23#P
#6
S22#P
#5
S21#P
#4
S20#P
#3
S19#P
#2
S18#P
#1
S17#P
#0
S16#P
Fn025
#7
S31#P
#6
S30#P
#5
S29#P
#4
S28#P
#3
S27#P
#2
S26#P
#1
S25#P
#0
S24#P
Fn026
#7
T07#P
#6
T06#P
#5
T05#P
#4
T04#P
#3
T03#P
#2
T02#P
#1
T01#P
#0
T00#P
Fn027
#7
T15#P
#6
T14#P
#5
T13#P
#4
T12#P
#3
T11#P
#2
T10#P
#1
T09#P
#0
T08#P
Fn028
#7
T23#P
#6
T22#P
#5
T21#P
#4
T20#P
#3
T19#P
#2
T18#P
#1
T17#P
#0
T16#P
Fn029
#7
T31#P
#6
T30#P
#5
T29#P
#4
T28#P
#3
T27#P
#2
T26#P
#1
T25#P
#0
T24#P
Fn030
#7
B07#P
#6
B06#P
#5
B05#P
#4
B04#P
#3
B03#P
#2
B02#P
#1
B01#P
#0
B00#P
Fn031
#7
B15#P
#6
B14#P
#5
B13#P
#4
B12#P
#3
B11#P
#2
B10#P
#1
B09#P
#0
B08#P
Fn032
#7
B23#P
#6
B22#P
#5
B21#P
#4
B20#P
#3
B19#P
#2
B18#P
#1
B17#P
#0
B16#P
Fn033
#7
B31#P
#6
B30#P
#5
B29#P
#4
B28#P
#3
B27#P
#2
B26#P
#1
B25#P
#0
B24#P
#7
#6
#5
#4
#3
#2
#1
#0
GR3O#P
GR2O#P
GR1O#P
Fn020
Fn021
Fn034
SRSRDY
SRSP1R
SRSP2R
SRSP3R
SRSP4R
#P
#SP
#SP
#SP
#SP
177
Interface between CNC and PMC
B-64805EN/03
#7
#6
#5
#4
#3
#2
#1
#0
SPAL#P
#7
R08O#SP
#6
R07O#SP
#5
R06O#SP
#4
R05O#SP
#3
R04O#SP
#2
R03O#SP
#1
R02O#SP
#0
R01O#SP
#7
#6
#5
#4
#3
R12O#SP
#2
R11O#SP
#1
R10O#SP
#0
R09O#SP
#7
#6
#5
#4
#3
#2
ENB3#SP
ENB2#SP
#1
SUCLPA
#0
SCLPA#S
#SP
P
#3
CHPCYL
#2
CHPMD#
#1
#P
P
ENB4#SP
#0
MSPOS
A#SP
Fn035
Fn036
Fn037
Fn038
#7
#6
#5
#4
Fn039
Fn040
#7
AR07#SP
#6
AR06#SP
#5
AR05#SP
#4
AR04#SP
#3
AR03#SP
#2
AR02#SP
#1
AR01#SP
#0
AR00#SP
Fn041
#7
AR15#SP
#6
AR14#SP
#5
AR13#SP
#4
AR12#SP
#3
AR11#SP
#2
AR10#SP
#1
AR09#SP
#0
AR08#SP
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
SYCAL4
#2
SYCAL3
#1
SYCAL2
#0
SYCAL1
#SP
#SP
#SP
#SP
Fn042
Fn043
#7
#6
#5
#4
SYCAL#P
#3
FSPPH#P
#2
FSPSY#P
#1
FSCSL#P
#0
#7
ORARA#
#6
#5
LDT2A#S
#4
LDT1A#S
#3
#2
#1
#0
P
P
SARA#SP
SDTA#SP
SSTA#SP
ALMA#SP
#0
Fn044
Fn045
Fn046
Fn047
SP
TLMA#SP
#7
MORA2
A#SP
#6
MORA1
A#SP
#5
PORA2A
#4
SLVSA#S
#3
RCFNA#
#2
RCHPA#
#1
CFINA#S
#SP
P
SP
SP
P
CHPA#SP
#7
CSYFNA
#6
CS1DTA
#5
#4
#2
#1
INCSTA#
#0
PC1DTA
#SP
#SP
#3
SOREN
A
SP
#SP
#7
#6
#3
#2
#1
#0
#3
#2
#1
#0
EXOFA
#5
Fn048
#SP
#7
178
#4
CSPENA
#6
#5
#4
B-64805EN/03
Fn049
Fn050
Fn051
Interface between CNC and PMC
ORARB#
LDT2B#S
LDT1B#S
P
P
SARB#SP
SDTB#SP
SSTB#SP
ALMB#SP
#6
MORA1
B#SP
#5
PORA2B
#4
SLVSB#S
#3
RCFNB#
#2
RCHPB#
#1
CFINB#S
#0
#SP
P
SP
SP
P
CHPB#SP
#7
CSYFNB
#6
CS1DTB
#5
#4
#2
#1
INCSTB#
#0
PC1DTB
#SP
#SP
#3
SOREN
B
SP
#SP
#7
#6
#3
#2
#1
#0
#3
#2
#1
#0
IOALM#P
IOBSY#P
PRGDPL
SP
TLMB#SP
#7
MORA2
B#SP
EXOFB
#5
Fn052
#4
CSPENB
#SP
#7
#6
#5
#4
BGEAC
T#P
Fn053
EKENB
Fn054
#7
UO007#P
#6
UO006#P
#5
UO005#P
#4
UO004#P
#3
UO003#P
#2
UO002#P
#1
UO001#P
#0
UO000#P
Fn055
#7
UO015#P
#6
UO014#P
#5
UO013#P
#4
UO012#P
#3
UO011#P
#2
UO010#P
#1
UO009#P
#0
UO008#P
Fn056
#7
UO107#P
#6
UO106#P
#5
UO105#P
#4
UO104#P
#3
UO103#P
#2
UO102#P
#1
UO101#P
#0
UO100#P
Fn057
#7
UO115#P
#6
UO114#P
#5
UO113#P
#4
UO112#P
#3
UO111#P
#2
UO110#P
#1
UO109#P
#0
UO108#P
Fn058
#7
UO123#P
#6
UO122#P
#5
UO121#P
#4
UO120#P
#3
UO119#P
#2
UO118#P
#1
UO117#P
#0
UO116#P
Fn059
#7
UO131#P
#6
UO130#P
#5
UO129#P
#4
UO128#P
#3
UO127#P
#2
UO126#P
#1
UO125#P
#0
UO124#P
#7
#6
#5
#4
#3
#2
ESCAN#
#1
ESEND#
#0
EREND#
P
P
P
#2
#1
#0
BUCLP#
Fn060
#7
#6
#5
#4
#3
BCLP#P
Fn061
Fn062
#7
#6
PRTSF#P
D3ROT#P
MTLA#P
MTLAN
G#P
#5
#4
HCEXE
#3
P
HCAB2
#2
HSRA#P
#1
#0
AICC#P
179
Interface between CNC and PMC
Fn063
Fn064
B-64805EN/03
S2MES#P
S1MES#P
#7
PSYN#P
#6
WATO#P
#5
#4
COSP2#P
#3
COSP1#P
#2
PSAR#P
#1
PSE2#P
#0
PSE1#P
#7
#6
#5
#4
#3
#2
#1
#0
TIALM#P
TICHK#P
TLCHB#P
TLCHI#P
TLNW#P
TLCH#P
#7
#6
SYNMO
D#P
#5
#3
#2
RSMAX#
#1
RGSPM#
#0
RGSPP#
P
P
P
#6
#5
#2
#1
#0
FEED0#P
RTPT#P
Fn065
#7
COSP#P
#4
RTRCTF
#P
#4
#3
PECK2#P
Fn066
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn070
#7
PSW08#P
#6
PSW07#P
#5
PSW06#P
#4
PSW05#P
#3
PSW04#P
#2
PSW03#P
#1
PSW02#P
#0
PSW01#P
Fn071
#7
PSW16#P
#6
PSW15#P
#5
PSW14#P
#4
PSW13#P
#3
PSW12#P
#2
PSW11#P
#1
PSW10#P
#0
PSW09#P
Fn072
#7
OUT7#P
#6
OUT6#P
#5
OUT5#P
#4
OUT4#P
#3
OUT3#P
#2
OUT2#P
#1
OUT1#P
#0
OUT0#P
#7
#6
#5
#4
ZRNO#P
#3
#2
MD4O#P
#1
MD2O#P
#0
MD1O#P
Fn074
#7
OUT15#P
#6
OUT14#P
#5
OUT13#P
#4
OUT12#P
#3
OUT11#P
#2
OUT10#P
#1
OUT9#P
#0
OUT8#P
#6
KEYO
#5
DRNO#P
#4
MLKO#P
#3
SBKO#P
#2
BDTO#P
#1
#0
Fn075
#7
SPO#P
#7
#6
#5
ROV2O#
#4
ROV1O#
#3
#2
#1
#0
P
P
MP2O#P
MP1O#P
Fn067
Fn068
Fn069
Fn073
Fn076
180
RTAP#P
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
RTO#P
Fn077
#3
HS1DO#
#2
HS1CO#
#1
HS1BO#
#0
HS1AO#
P
P
P
P
Fn078
#7
*FV7O#P
#6
*FV6O#P
#5
*FV5O#P
#4
*FV4O#P
#3
*FV3O#P
#2
*FV2O#P
#1
*FV1O#P
#0
*FV0O#P
Fn079
#7
*JV7O#P
#6
*JV6O#P
#5
*JV5O#P
#4
*JV4O#P
#3
*JV3O#P
#2
*JV2O#P
#1
*JV1O#P
#0
*JV0O#P
#7
*JV15O#
#6
*JV14O#
#5
*JV13O#
#4
*JV12O#
#3
*JV11O#
#2
*JV10O#
#1
#0
P
P
P
P
P
P
*JV9O#P
*JV8O#P
#7
-J4O#P
#6
+J4O#P
#5
-J3O#P
#4
+J3O#P
#3
-J2O#P
#2
+J2O#P
#1
-J1O#P
#0
+J1O#P
#7
#6
#5
#4
#3
#2
#1
CGRMD#
#0
Fn080
Fn081
RVSL#P
EGBSM#
Fn082
P
P
#7
#6
#5
#4
#3
#2
#1
#0
Fn084
#7
EUO07#P
#6
EUO06#P
#5
EUO05#P
#4
EUO04#P
#3
EUO03#P
#2
EUO02#P
#1
EUO01#P
#0
EUO00#P
Fn085
#7
EUO15#P
#6
EUO14#P
#5
EUO13#P
#4
EUO12#P
#3
EUO11#P
#2
EUO10#P
#1
EUO09#P
#0
EUO08#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#0
ABTSP3
ABTSP2
ABTQSV
P
SYAR#P
#1
ABTSP1
#SP
#SP
#SP
#P
#5
#4
#3
#2
#1
#0
Fn083
Fn086
Fn087
Fn088
Fn089
Fn090
SVSPM#
P
SVAR#P
#7
#6
SYSSM#
181
Interface between CNC and PMC
ADCO#P
Fn091
#7
Fn092
Fn093
Fn094
B-64805EN/03
#6
HSBIN#P
#5
TRSPS#P
ABTSP4
MMMOD
MRVSP#
MNCHG#
MRVMD#
#SP
#P
P
P
P
#4
TRMTN#
#3
#2
#1
#0
#3
#2
#1
WFAN#P
LFCIF#P
SFAN#P
#0
LIFOVR#
P
TRACT#P
#7
SVWRN
4#P
#6
SVWRN
3#P
#5
SVWRN
2#P
#4
SVWRN
1#P
#7
ZP8#SV
#6
ZP7#SV
#5
ZP6#SV
#4
ZP5#SV
#3
ZP4#SV
#2
ZP3#SV
#1
ZP2#SV
#0
ZP1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
ZP28#SV
#6
ZP27#SV
#5
ZP26#SV
#4
ZP25#SV
#3
ZP24#SV
#2
ZP23#SV
#1
ZP22#SV
#0
ZP21#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
ZP38#SV
#6
ZP37#SV
#5
ZP36#SV
#4
ZP35#SV
#3
ZP34#SV
#2
ZP33#SV
#1
ZP32#SV
#0
ZP31#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
ZP48#SV
#6
ZP47#SV
#5
ZP46#SV
#4
ZP45#SV
#3
ZP44#SV
#2
ZP43#SV
#1
ZP42#SV
#0
ZP41#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
MV8#SV
#6
MV7#SV
#5
MV6#SV
#4
MV5#SV
#3
MV4#SV
#2
MV3#SV
#1
MV2#SV
#0
MV1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
INP8#SV
#6
INP7#SV
#5
INP6#SV
#4
INP5#SV
#3
INP4#SV
#2
INP3#SV
#1
INP2#SV
#0
INP1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
MVD8#SV
#6
MVD7#SV
#5
MVD6#SV
#4
MVD5#SV
#3
MVD4#SV
#2
MVD3#SV
#1
MVD2#SV
#0
MVD1#SV
P
Fn095
Fn096
Fn097
Fn098
Fn099
Fn100
Fn101
Fn102
Fn103
Fn104
Fn105
Fn106
182
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
#3
#2
#1
#0
#7
MMI8#SV
#6
MMI7#SV
#5
MMI6#SV
#4
MMI5#SV
#3
MMI4#SV
#2
MMI3#SV
#1
MMI2#SV
#0
MMI1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
MDTCH8
#6
MDTCH7
#5
MDTCH6
#4
MDTCH5
#3
MDTCH4
#2
MDTCH3
#1
MDTCH2
#0
MDTCH1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
EADEN8
#6
EADEN7
#5
EADEN6
#4
EADEN5
#3
EADEN4
#2
EADEN3
#1
EADEN2
#0
EADEN1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
TRQL8#S
#6
TRQL7#S
#5
TRQL6#S
#4
TRQL5#S
#3
TRQL4#S
#2
TRQL3#S
#1
TRQL2#S
#0
TRQL1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
#7
FRP8#SV
#6
FRP7#SV
#5
FRP6#SV
#4
FRP5#SV
#3
FRP4#SV
#2
FRP3#SV
#1
FRP2#SV
#0
FRP1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
SYN8O#S
#6
SYN7O#S
#5
SYN6O#S
#4
SYN5O#S
#3
SYN4O#S
#2
SYN3O#S
#1
SYN2O#S
#0
SYN1O#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
#7
ZRF8#SV
#6
ZRF7#SV
#5
ZRF6#SV
#4
ZRF5#SV
#3
ZRF4#SV
#2
ZRF3#SV
#1
ZRF2#SV
#0
ZRF1#SV
#7
#6
#5
#4
#3
#2
#1
#0
Fn107
Fn108
Fn109
Fn110
Fn111
Fn112
Fn113
Fn114
Fn115
Fn116
Fn117
Fn118
Fn119
Fn120
Fn121
183
Interface between CNC and PMC
Fn122
B-64805EN/03
#7
HDO7#P
#6
HDO6#P
#5
HDO5#P
#4
HDO4#P
#3
HDO3#P
#2
HDO2#P
#1
HDO1#P
#0
HDO0#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
+OT8#SV
#6
+OT7#SV
#5
+OT6#SV
#4
+OT5#SV
#3
+OT4#SV
#2
+OT3#SV
#1
+OT2#SV
#0
+OT1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
-OT8#SV
#6
-OT7#SV
#5
-OT6#SV
#4
-OT5#SV
#3
-OT4#SV
#2
-OT3#SV
#1
-OT2#SV
#0
-OT1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
*EAXSL#
#6
#5
#4
#3
#2
#1
#0
Fn123
Fn124
Fn125
Fn126
Fn127
Fn128
Fn129
Fn130
EOV0#P
P
#7
EBSYA#
#6
EOTNA#
#5
EOTPA#
#4
EGENA#
#3
EDENA#
#2
EIALA#P
#1
ECKZA#
#0
EINPA#P
PX
PX
PX
PX
PX
X
PX
X
#7
#6
#5
#4
#3
EMF3A#P
#2
EMF2A#P
#1
EABUFA
#0
X
X
#PX
EMFA#PX
Fn131
Fn132
Fn133
#7
EM28A#P
#6
EM24A#P
#5
EM22A#P
#4
EM21A#P
#3
EM18A#P
#2
EM14A#P
#1
EM12A#P
#0
EM11A#P
X
X
X
X
X
X
X
X
#7
EBSYB#
#6
EOTNB#
#5
EOTPB#
#4
EGENB#
#3
EDENB#
#2
EIALB#P
#1
ECKZB#
#0
EINPB#P
PX
PX
PX
PX
PX
X
PX
X
#7
#6
#5
#4
#3
EMF3B#P
#2
EMF2B#P
#1
EABUFB
#0
X
X
#PX
EMFB#PX
Fn134
Fn135
184
#7
EM28B#P
#6
EM24B#P
#5
EM22B#P
#4
EM21B#P
#3
EM18B#P
#2
EM14B#P
#1
EM12B#P
#0
EM11B#P
X
X
X
X
X
X
X
X
B-64805EN/03
Fn136
Interface between CNC and PMC
#7
EBSYC#
#6
EOTNC#
#5
EOTPC#
#4
EGENC#
#3
EDENC#
#2
EIALC#P
#1
ECKZC#
#0
EINPC#P
PX
PX
PX
PX
PX
X
PX
X
#7
#6
#5
#4
#3
EMF3C#P
#2
EMF2C#P
#1
EABUFC
#0
X
X
#PX
EMFC#PX
Fn137
Fn138
Fn139
#7
EM28C#P
#6
EM24C#P
#5
EM22C#P
#4
EM21C#P
#3
EM18C#P
#2
EM14C#P
#1
EM12C#P
#0
EM11C#P
X
X
X
X
X
X
X
X
#7
EBSYD#
#6
EOTND#
#5
EOTPD#
#4
EGEND#
#3
EDEND#
#2
EIALD#P
#1
ECKZD#
#0
EINPD#P
PX
PX
PX
PX
PX
X
PX
X
#7
#6
#5
#4
#3
EMF3D#P
#2
EMF2D#P
#1
EABUFD
#0
X
X
#PX
EMFD#PX
Fn140
Fn141
Fn142
#7
EM28D#P
#6
EM24D#P
#5
EM22D#P
#4
EM21D#P
#3
EM18D#P
#2
EM14D#P
#1
EM12D#P
#0
EM11D#P
X
X
X
X
X
X
X
X
#7
EM48A#P
#6
EM44A#P
#5
EM42A#P
#4
EM41A#P
#3
EM38A#P
#2
EM34A#P
#1
EM32A#P
#0
EM31A#P
X
X
X
X
X
X
X
X
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
EM48B#P
#6
EM44B#P
#5
EM42B#P
#4
EM41B#P
#3
EM38B#P
#2
EM34B#P
#1
EM32B#P
#0
EM31B#P
X
X
X
X
X
X
X
X
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
EM48C#P
#6
EM44C#P
#5
EM42C#P
#4
EM41C#P
#3
EM38C#P
#2
EM34C#P
#1
EM32C#P
#0
EM31C#P
X
X
X
X
X
X
X
X
#7
#6
#5
#4
#3
#2
#1
#0
Fn143
Fn144
Fn145
Fn146
Fn147
Fn148
Fn149
185
Interface between CNC and PMC
B-64805EN/03
#7
#6
#5
#4
#3
#2
#1
#0
#7
EM48D#P
#6
EM44D#P
#5
EM42D#P
#4
EM41D#P
#3
EM38D#P
#2
EM34D#P
#1
EM32D#P
#0
EM31D#P
X
X
X
X
X
X
X
X
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn150
Fn151
Fn152
Fn153
TLAL#P
Fn154
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn160
#7
MSP07#P
#6
MSP06#P
#5
MSP05#P
#4
MSP04#P
#3
MSP03#P
#2
MSP02#P
#1
MSP01#P
#0
MSP00#P
Fn161
#7
MSP15#P
#6
MSP14#P
#5
MSP13#P
#4
MSP12#P
#3
MSP11#P
#2
MSP10#P
#1
MSP09#P
#0
MSP08#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn155
Fn156
Fn157
Fn158
Fn159
Fn162
Fn163
Fn164
186
B-64805EN/03
Interface between CNC and PMC
Fn165
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
ORARC#
#6
#5
LDT2C#S
#4
LDT1C#S
#3
#2
#1
#0
P
P
SARC#SP
SDTC#SP
SSTC#SP
ALMC#SP
#0
Fn166
Fn167
Fn168
Fn169
Fn170
SP
TLMC#SP
#7
MORA2
C#SP
#6
MORA1
C#SP
#5
PORA2C
#4
SLVSC#S
#3
RCFNC#
#2
RCHPC#
#1
CFINC#S
#SP
P
SP
SP
P
CHPC#SP
#7
CSYFNC
#6
CS1DTC
#5
#4
#2
#1
INCSTC#
#0
PC1DTC
#SP
#SP
#3
SOREN
C
SP
#SP
#7
#6
#3
#2
#1
#0
EXOFC
#5
Fn171
Fn172
#4
CSPENC
#SP
#7
PBATL#P
#6
PBATZ#P
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn173
Fn174
Fn175
Fn176
Fn177
Fn178
Fn179
187
Interface between CNC and PMC
Fn180
B-64805EN/03
CLRCH8
CLRCH7
CLRCH6
CLRCH5
CLRCH4
CLRCH3
CLRCH2
CLRCH1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
EACNT8
#6
EACNT7
#5
EACNT6
#4
EACNT5
#3
EACNT4
#2
EACNT3
#1
EACNT2
#0
EACNT1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
ABDT8#S
#6
ABDT7#S
#5
ABDT6#S
#4
ABDT5#S
#3
ABDT4#S
#2
ABDT3#S
#1
ABDT2#S
#0
ABDT1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
TRQM8#
#6
TRQM7#
#5
TRQM6#
#4
TRQM5#
#3
TRQM4#
#2
TRQM3#
#1
TRQM2#
#0
TRQM1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
PRS#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn181
Fn182
Fn183
Fn184
Fn185
Fn186
Fn187
Fn188
Fn189
Fn190
Fn191
Fn192
Fn193
Fn194
188
B-64805EN/03
Interface between CNC and PMC
Fn195
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
MFSYN
D#P
#2
MFSYN
C#P
#1
MFSYN
B#P
#0
MFSYN
A#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
MCHAO#
#4
#3
#2
#1
#0
Fn196
Fn197
Fn198
Fn199
Fn200
P
#7
R08O2#S
#6
R07O2#S
#5
R06O2#S
#4
R05O2#S
#3
R04O2#S
#2
R03O2#S
#1
R02O2#S
#0
R01O2#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
R12O2#S
#2
R11O2#S
#1
R10O2#S
#0
R09O2#S
P
P
P
P
Fn201
Fn202
Fn203
Fn204
#7
AR072#S
#6
AR062#S
#5
AR052#S
#4
AR042#S
#3
AR032#S
#2
AR022#S
#1
AR012#S
#0
AR002#S
P
P
P
P
P
P
P
P
#7
AR152#S
#6
AR142#S
#5
AR132#S
#4
AR122#S
#3
AR112#S
#2
AR102#S
#1
AR092#S
#0
AR082#S
P
P
P
P
P
P
P
P
#7
R08O3#S
#6
R07O3#S
#5
R06O3#S
#4
R05O3#S
#3
R04O3#S
#2
R03O3#S
#1
R02O3#S
#0
R01O3#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
R12O3#S
#2
R11O3#S
#1
R10O3#S
#0
R09O3#S
P
P
P
P
Fn205
Fn206
Fn207
Fn208
#7
AR073#S
#6
AR063#S
#5
AR053#S
#4
AR043#S
#3
AR033#S
#2
AR023#S
#1
AR013#S
#0
AR003#S
P
P
P
P
P
P
P
P
#7
AR153#S
#6
AR143#S
#5
AR133#S
#4
AR123#S
#3
AR113#S
#2
AR103#S
#1
AR093#S
#0
AR083#S
P
P
P
P
P
P
P
P
#7
EGBM8#
#6
EGBM7#
#5
EGBM6#
#4
EGBM5#
#3
EGBM4#
#2
EGBM3#
#1
EGBM2#
#0
EGBM1#
SV
SV
SV
SV
SV
SV
SV
SV
189
Interface between CNC and PMC
B-64805EN/03
#7
#6
#5
#4
#3
#2
#1
#0
#7
SYNMT8
#6
SYNMT7
#5
SYNMT6
#4
SYNMT5
#3
SYNMT4
#2
SYNMT3
#1
SYNMT2
#0
SYNMT1
#P
#P
#P
#P
#P
#P
#P
#P
#7
SYNOF8
#6
SYNOF7
#5
SYNOF6
#4
SYNOF5
#3
SYNOF4
#2
SYNOF3
#1
SYNOF2
#0
SYNOF1
#P
#P
#P
#P
#P
#P
#P
#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
SPWRN
8#P
#6
SPWRN
7#P
#5
SPWRN
6#P
#4
SPWRN
5#P
#3
SPWRN
4#P
#2
SPWRN
3#P
#1
SPWRN
2#P
#0
SPWRN
1#P
#7
#6
#5
#4
#3
#2
#1
#0
SPWRN
9#P
#7
ORARD#
#6
#5
LDT2D#S
#4
LDT1D#S
#3
#2
#1
#0
P
P
SARD#SP
SDTD#SP
SSTD#SP
ALMD#SP
#5
#4
#3
#2
#1
#0
Fn209
Fn210
Fn211
Fn212
Fn213
Fn214
Fn215
Fn216
Fn217
Fn218
Fn263
Fn264
Fn265
Fn266
190
SP
TLMD#SP
#7
#6
B-64805EN/03
Fn267
Fn268
Interface between CNC and PMC
MORA2
D#SP
MORA1
D#SP
PORA2D
SLVSD#S
RCFND#
RCHPD#
CFIND#S
#SP
P
SP
SP
P
CHPD#SP
#7
CSYFND
#6
CS1DTD
#5
#4
#2
#1
INCSTD#
#0
PC1DTD
#SP
#SP
#3
SOREN
D
SP
#SP
#7
#6
#3
#2
#1
#0
EXOFD
#5
Fn269
Fn270
#4
CSPEND
#SP
#7
R08O4#S
#6
R07O4#S
#5
R06O4#S
#4
R05O4#S
#3
R04O4#S
#2
R03O4#S
#1
R02O4#S
#0
R01O4#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
R12O4#S
#2
R11O4#S
#1
R10O4#S
#0
R09O4#S
P
P
P
P
Fn271
#7
AR074#S
#6
AR064#S
#5
AR054#S
#4
AR044#S
#3
AR034#S
#2
AR024#S
#1
AR014#S
#0
AR004#S
P
P
P
P
P
P
P
P
#7
AR154#S
#6
AR144#S
#5
AR134#S
#4
AR124#S
#3
AR114#S
#2
AR104#S
#1
AR094#S
#0
AR084#S
P
P
P
P
P
P
P
P
#7
CSFO4#S
#6
CSFO3#S
#5
CSFO2#S
#4
CSFO1#S
#3
FCSS4#S
#2
FCSS3#S
#1
FCSS2#S
#0
FCSS1#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
Fn276
#7
UO023#P
#6
UO022#P
#5
UO021#P
#4
UO020#P
#3
UO019#P
#2
UO018#P
#1
UO017#P
#0
UO016#P
Fn277
#7
UO031#P
#6
UO030#P
#5
UO029#P
#4
UO028#P
#3
UO027#P
#2
UO026#P
#1
UO025#P
#0
UO024#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
UO207#P
#6
UO206#P
#5
UO205#P
#4
UO204#P
#3
UO203#P
#2
UO202#P
#1
UO201#P
#0
UO200#P
#7
#6
#5
#4
#3
#2
#1
#0
Fn272
Fn273
Fn274
Fn275
Fn278
Fn279
Fn280
191
Interface between CNC and PMC
B-64805EN/03
Fn281
UO215#P
UO214#P
UO213#P
UO212#P
UO211#P
UO210#P
UO209#P
UO208#P
Fn282
#7
UO223#P
#6
UO222#P
#5
UO221#P
#4
UO220#P
#3
UO219#P
#2
UO218#P
#1
UO217#P
#0
UO216#P
Fn283
#7
UO231#P
#6
UO230#P
#5
UO229#P
#4
UO228#P
#3
UO227#P
#2
UO226#P
#1
UO225#P
#0
UO224#P
Fn284
#7
UO307#P
#6
UO306#P
#5
UO305#P
#4
UO304#P
#3
UO303#P
#2
UO302#P
#1
UO301#P
#0
UO300#P
Fn285
#7
UO315#P
#6
UO314#P
#5
UO313#P
#4
UO312#P
#3
UO311#P
#2
UO310#P
#1
UO309#P
#0
UO308#P
Fn286
#7
UO323#P
#6
UO322#P
#5
UO321#P
#4
UO320#P
#3
UO319#P
#2
UO318#P
#1
UO317#P
#0
UO316#P
Fn287
#7
UO331#P
#6
UO330#P
#5
UO329#P
#4
UO328#P
#3
UO327#P
#2
UO326#P
#1
UO325#P
#0
UO324#P
#7
#6
#5
#4
#3
FSPSY4#
#2
FSPSY3#
#1
FSPSY2#
#0
FSPSY1#
SP
SP
SP
SP
#3
FSPPH4
#2
FSPPH3
#1
FSPPH2
#0
FSPPH1
#SP
#SP
#SP
#SP
#3
#2
#1
#0
Fn288
#7
#6
#5
#4
Fn289
Fn290
#7
IMMDO#
#6
P
#5
PRGMD#
#4
PCKSV#
P
P
DNTCM
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
ITED
#2
#1
#0
Fn293
#7
HPS08#P
#6
HPS07#P
#5
HPS06#P
#4
HPS05#P
#3
HPS04#P
#2
HPS03#P
#1
HPS02#P
#0
HPS01#P
Fn294
#7
HPS16#P
#6
HPS15#P
#5
HPS14#P
#4
HPS13#P
#3
HPS12#P
#2
HPS11#P
#1
HPS10#P
#0
HPS09#P
#7
CNCKY
O
#6
#5
#4
#3
#2
#1
#0
#5
#4
#3
#2
#1
#0
Fn291
Fn292
Fn295
#7
192
C2SENO
#6
B-64805EN/03
Fn296
Interface between CNC and PMC
DM8#SV
DM7#SV
DM6#SV
DM5#SV
DM4#SV
DM3#SV
DM2#SV
DM1#SV
#7
#6
#5
MCHAO#
#4
#3
#2
#1
#0
MBCAN#
Fn297
Fn298
Fn299
P
P
#7
TDSML8
#6
TDSML7
#5
TDSML6
#4
TDSML5
#3
TDSML4
#2
TDSML3
#1
TDSML2
#0
TDSML1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
TDFTR8#
#6
TDFTR7#
#5
TDFTR6#
#4
TDFTR5#
#3
TDFTR4#
#2
TDFTR3#
#1
TDFTR2#
#0
TDFTR1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
VDCAB
A
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
INESFN
A
#1
#0
XPFLA
FRDTEA
Fn300
Fn301
Fn302
Fn303
Fn304
Fn305
Fn306
Fn307
#7
#6
#5
#4
VDCAB
B
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
INESFN
B
#1
#0
XPFLB
FRDTEB
#1
#0
Fn308
Fn309
#7
#6
#5
#4
#3
#2
193
Interface between CNC and PMC
B-64805EN/03
VDCAB
C
Fn310
#7
#6
#5
#4
#3
Fn311
#2
INESFN
C
#1
#0
XPFLC
FRDTEC
#7
#6
#5
#4
VDCAB
D
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
INESFN
D
#1
#0
XPFLD
FRDTED
Fn312
Fn313
#7
#6
#5
#4
#3
#2
#1
#0
#7
TLMEM#
#6
TMFNFD
#5
#4
TLMOT#
#3
#2
TLMG10
#1
TLMSRH
#0
P
#P
#P
#P
TLSKF#P
#7
SQMPE#
#6
SQMPR#
P
P
#7
Fn314
Fn315
Fn316
P
#5
#4
#3
#2
#1
#0
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn317
Fn318
Fn319
Fn320
Fn321
Fn322
Fn323
Fn324
194
B-64805EN/03
Interface between CNC and PMC
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
TLCHI4#
#6
TLCHI3#
#5
TLCHI2#
#4
TLCHI1#
#3
#2
#1
#0
P
P
P
P
TLCH4#P
TLCH3#P
TLCH2#P
TLCH1#P
#7
TLCHB4
#6
TLCHB3
#5
TLCHB2
#4
TLCHB1
#3
TLSKF4#
#2
TLSKF3#
#1
TLSKF2#
#0
TLSKF1#
#P
#P
#P
#P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn325
Fn326
Fn327
Fn328
Fn329
Fn330
Fn331
Fn332
Fn333
Fn334
Fn335
Fn336
Fn337
Fn338
Fn339
195
Interface between CNC and PMC
B-64805EN/03
Fn340
Fn341
Fn342
Fn343
Fn344
Fn345
Fn346
Fn347
#7
SYCM8#
#6
SYCM7#
#5
SYCM6#
#4
SYCM5#
#3
SYCM4#
#2
SYCM3#
#1
SYCM2#
#0
SYCM1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
SYCS8#S
#6
SYCS7#S
#5
SYCS6#S
#4
SYCS5#S
#3
SYCS4#S
#2
SYCS3#S
#1
SYCS2#S
#0
SYCS1#S
V
V
V
V
V
V
V
V
#7
MIXO8#S
#6
MIXO7#S
#5
MIXO6#S
#4
MIXO5#S
#3
MIXO4#S
#2
MIXO3#S
#1
MIXO2#S
#0
MIXO1#S
V
V
V
V
V
V
V
V
#7
OVMO8#
#6
OVMO7#
#5
OVMO6#
#4
OVMO5#
#3
OVMO4#
#2
OVMO3#
#1
OVMO2#
#0
OVMO1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
OVSO8#
#6
OVSO7#
#5
OVSO6#
#4
OVSO5#
#3
OVSO4#
#2
OVSO3#
#1
OVSO2#
#0
OVSO1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
SMPK8#
#6
SMPK7#
#5
SMPK6#
#4
SMPK5#
#3
SMPK4#
#2
SMPK3#
#1
SMPK2#
#0
SMPK1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
D3MI#P
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
SSEGB
M4#SP
#2
SSEGB
M3#SP
#1
SSEGB
M2#SP
#0
SSEGB
M1#SP
#7
#6
#5
#4
#3
#2
#1
THREND
#0
MTHML#
#P
P
Fn348
Fn349
Fn350
Fn351
Fn356
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn357
196
B-64805EN/03
Fn358
Fn376
Fn377
Interface between CNC and PMC
WPSF8#
WPSF7#
WPSF6#
WPSF5#
WPSF4#
WPSF3#
WPSF2#
WPSF1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
SVSST8#
#6
SVSST7#
#5
SVSST6#
#4
SVSST5#
#3
SVSST4#
#2
SVSST3#
#1
SVSST2#
#0
SVSST1#
SV
SV
SV
SV
SV
SV
SV
SV
#7
SVSAR8
#6
SVSAR7
#5
SVSAR6
#4
SVSAR5
#3
SVSAR4
#2
SVSAR3
#1
SVSAR2
#0
SVSAR1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
#6
#5
#4
#3
PHFIND#
#2
PHFINC#
#1
PHFINB#
#0
PHFINA#
P
P
P
P
Fn381
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
SUCLPD
#2
SUCLPC
#1
SUCLPB
#0
#SP
#SP
#SP
#3
SCLPD#S
#2
SCLPC#S
#1
SCLPB#S
P
P
P
Fn395
Fn396
Fn397
Fn398
Fn399
Fn400
#7
#6
#5
#4
Fn401
#0
#7
#6
#5
#4
#3
MSPOS
D#SP
#2
MSPOS
C#SP
#1
MSPOS
B#SP
#0
#7
#6
#5
#4
#3
#2
#1
#0
SYNER#
Fn402
Fn403
P
#7
#6
#5
#4
#3
#2
#1
COSP4#P
#0
COSP3#P
#7
#6
#5
#4
#3
#2
#1
#0
Fn404
197
Interface between CNC and PMC
B-64805EN/03
Fn405
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
MCSP#P
MCRQ#P
#0
MCEXE#
Fn406
Fn407
Fn408
Fn409
Fn410
Fn411
Fn412
Fn413
Fn414
Fn415
Fn416
Fn417
Fn418
Fn511
Fn512
198
P
B-64805EN/03
Interface between CNC and PMC
#7
ZRNR#P
#6
#5
DNCIR#P
#4
#3
#2
MD4R#P
#1
MD2R#P
#0
MD1R#P
#7
MCEX8#
#6
MCEX7#
#5
MCEX6#
#4
MCEX5#
#3
MCEX4#
#2
MCEX3#
#1
MCEX2#
#0
MCEX1#
P
P
P
P
P
P
P
P
#7
MCEX16
#6
MCEX15
#5
MCEX14
#4
MCEX13
#3
MCEX12
#2
MCEX11
#1
MCEX10
#0
MCEX9#
#P
#P
#P
#P
#P
#P
#P
P
#7
MSEMI8#
#6
MSEMI7#
#5
MSEMI6#
#4
MSEMI5#
#3
MSEMI4#
#2
MSEMI3#
#1
MSEMI2#
#0
MSEMI1#
SV
SV
SV
SV
SV
SV
SV
SV
Fn517
#7
RP18#SV
#6
RP17#SV
#5
RP16#SV
#4
RP15#SV
#3
RP14#SV
#2
RP13#SV
#1
RP12#SV
#0
RP11#SV
Fn518
#7
RP28#SV
#6
RP27#SV
#5
RP26#SV
#4
RP25#SV
#3
RP24#SV
#2
RP23#SV
#1
RP22#SV
#0
RP21#SV
#7
#6
#5
#4
#2
#1
#0
PTOFS#P
PTRDY#P
PTCVA#P
PTCNV#P
#3
PTMOD#
#7
#6
#5
#4
#3
#2
#1
#0
ATBK
#7
SVREV8
#6
SVREV7
#5
SVREV6
#4
SVREV5
#3
SVREV4
#2
SVREV3
#1
SVREV2
#0
SVREV1
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#SV
#7
SPP8#SV
#6
SPP7#SV
#5
SPP6#SV
#4
SPP5#SV
#3
SPP4#SV
#2
SPP3#SV
#1
SPP2#SV
#0
SPP1#SV
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
#7
SSYO4#S
#6
SSYO3#S
#5
SSYO2#S
#4
SSYO1#S
#3
SGNO4#
#2
SGNO3#
#1
SGNO2#
#0
SGNO1#
P
P
P
P
SP
SP
SP
SP
#7
#6
#5
DWL#P
#4
#3
#2
#1
#0
#7
SYPER#P
#6
SYPFN#P
#5
#4
#3
#2
#1
#0
Fn513
Fn514
Fn515
Fn516
Fn519
P
Fn520
Fn521
Fn522
Fn523
Fn524
Fn525
Fn526
Fn527
199
Interface between CNC and PMC
B-64805EN/03
#7
#6
P2ACC#P
#5
#4
#3
#2
#1
#0
#7
#6
DVCPR#
#5
#4
#3
#2
#1
#0
P
TDIACK
TDICHK
MMDISL
FTCHG
#7
SYNO8#S
#6
SYNO7#S
#5
SYNO6#S
#4
SYNO5#S
#3
SYNO4#S
#2
SYNO3#S
#1
SYNO2#S
#0
SYNO1#S
V
V
V
V
V
V
V
V
#7
#6
#5
#4
#3
#2
#1
#0
#7
PE3EX
#6
PE2EX
#5
PE1EX
#4
MBSO#P
#3
#2
#1
SRNEX
#0
Fn534
Fn535
#7
WFLN2
#6
WFLN1
#5
WETF
#4
WETE
#3
WECCS
#2
WIOCH3
#1
WIOCH2
#0
WIOCH1
#7
#6
#5
#4
EXCED#
#3
ASNED#
#2
RMVED#
#1
#0
P
P
P
Fn528
Fn531
Fn532
IOLBR
Fn533
Fn536
INIST#P
Fn540
#7
TDIH4FE
#6
TDIH3FE
#5
TDIH2FE
#4
TDIH1FE
#3
TDIT4FE
#2
TDIT3FE
#1
TDIT2FE
#0
TDIT1FE
#7
#6
#5
TDIO6F
E
#4
TDIO5F
E
#3
TDIO4F
E
#2
TDIO3F
E
#1
TDIO2F
E
#0
TDIO1F
E
#7
TDIH4A
E
#6
TDIH3A
E
#5
TDIH2A
E
#4
TDIH1A
E
#3
#2
#1
#0
TDIT4AE
TDIT3AE
TDIT2AE
TDIT1AE
#7
#6
#5
TDIO6A
E
#4
TDIO5A
E
#3
TDIO4A
E
#2
TDIO3A
E
#1
TDIO2A
E
#0
TDIO1A
E
#7
PSIMF#P
#6
#5
#4
#3
#2
#1
PSIF2#P
#0
PSIF1#P
#7
#6
#5
#4
#3
#2
#1
OVLNS#
#0
Fn541
Fn542
Fn543
Fn544
Fn545
DNTER
#7
Fn546
200
#6
#5
#4
GTME#P
GTMC#P
P
FLANG
#3
CSMC4#
#2
CSMC3#
#1
CSMC2#
#0
CSMC1#
SP
SP
SP
SP
B-64805EN/03
Interface between CNC and PMC
#7
HPMER
R
#6
HPMSV
N
#5
HPMNT
S
#4
#3
#2
#1
#0
#7
#6
#5
#4
FSYSD#P
FSYSC#P
FSYSB#P
FSYSA#P
#3
PHERD#
#2
PHERC#
#1
PHERB#
#0
PHERA#
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
Fn558
#7
CDLAD5
#6
CDLAD4
#5
CDPRM
#4
CDDCL
#3
CDLAD3
#2
CDLAD2
#1
CDLAD1
#0
CDCEX
Fn559
#7
SEO8#SV
#6
SEO7#SV
#5
SEO6#SV
#4
SEO5#SV
#3
SEO4#SV
#2
SEO3#SV
#1
SEO2#SV
#0
SEO1#SV
#7
#6
#5
TDITO6#
#4
TDITO5#
#3
TDITO4#
#2
TDITO3#
#1
TDITO2#
#0
TDITO1#
P
P
P
P
P
P
#5
TDIHO6#
#4
TDIHO5#
#3
TDIHO4#
#2
TDIHO3#
#1
TDIHO2#
#0
TDIHO1#
P
P
P
P
P
P
Fn547
Fn553
Fn554
Fn560
#7
#6
Fn561
#7
#6
#5
#4
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
#0
Fn564
#7
M307#P
#6
M306#P
#5
M305#P
#4
M304#P
#3
M303#P
#2
M302#P
#1
M301#P
#0
M300#P
Fn565
#7
M315#P
#6
M314#P
#5
M313#P
#4
M312#P
#3
M311#P
#2
M310#P
#1
M309#P
#0
M308#P
Fn566
#7
M323#P
#6
M322#P
#5
M321#P
#4
M320#P
#3
M319#P
#2
M318#P
#1
M317#P
#0
M316#P
Fn567
#7
M331#P
#6
M330#P
#5
M329#P
#4
M328#P
#3
M327#P
#2
M326#P
#1
M325#P
#0
M324#P
Fn568
#7
M407#P
#6
M406#P
#5
M405#P
#4
M404#P
#3
M403#P
#2
M402#P
#1
M401#P
#0
M400#P
Fn569
#7
M415#P
#6
M414#P
#5
M413#P
#4
M412#P
#3
M411#P
#2
M410#P
#1
M409#P
#0
M408#P
Fn562
Fn563
201
Interface between CNC and PMC
B-64805EN/03
Fn570
#7
M423#P
#6
M422#P
#5
M421#P
#4
M420#P
#3
M419#P
#2
M418#P
#1
M417#P
#0
M416#P
Fn571
#7
M431#P
#6
M430#P
#5
M429#P
#4
M428#P
#3
M427#P
#2
M426#P
#1
M425#P
#0
M424#P
Fn572
#7
M507#P
#6
M506#P
#5
M505#P
#4
M504#P
#3
M503#P
#2
M502#P
#1
M501#P
#0
M500#P
Fn573
#7
M515#P
#6
M514#P
#5
M513#P
#4
M512#P
#3
M511#P
#2
M510#P
#1
M509#P
#0
M508#P
Fn574
#7
M523#P
#6
M522#P
#5
M521#P
#4
M520#P
#3
M519#P
#2
M518#P
#1
M517#P
#0
M516#P
Fn575
#7
M531#P
#6
M530#P
#5
M529#P
#4
M528#P
#3
M527#P
#2
M526#P
#1
M525#P
#0
M524#P
#7
#6
#5
#4
#3
#2
#1
#0
#7
SPMER4
#6
SPMER3
#5
SPMER2
#4
SPMER1
#3
SPMFN4
#2
SPMFN3
#1
SPMFN2
#0
SPMFN1
#7
#6
#5
ALLO
#4
#3
#2
WBCNT
#1
#0
#7
PRSO8#S
#6
PRSO7#S
#5
PRSO6#S
#4
PRSO5#S
#3
PRSO4#S
#2
PRSO3#S
#1
PRSO2#S
#0
PRSO1#S
V
V
V
V
V
V
V
V
#7
ARE07#S
#6
ARE06#S
#5
ARE05#S
#4
ARE04#S
#3
ARE03#S
#2
ARE02#S
#1
ARE01#S
#0
ARE00#S
P
P
P
P
P
P
P
P
#7
ARE15#S
#6
ARE14#S
#5
ARE13#S
#4
ARE12#S
#3
ARE11#S
#2
ARE10#S
#1
ARE09#S
#0
ARE08#S
P
P
P
P
P
P
P
P
#7
ARE23#S
#6
ARE22#S
#5
ARE21#S
#4
ARE20#S
#3
ARE19#S
#2
ARE18#S
#1
ARE17#S
#0
ARE16#S
P
P
P
P
P
P
P
P
#7
ARE31#S
#6
ARE30#S
#5
ARE29#S
#4
ARE28#S
#3
ARE27#S
#2
ARE26#S
#1
ARE25#S
#0
ARE24#S
P
P
P
P
P
P
P
P
#7
#6
#5
#4
#3
#2
#1
#0
Fn576
Fn577
Fn578
Fn579
Fn580
Fn581
Fn582
Fn583
202
B-64805EN/03
Fn584
Fn585
Fn586
Fn587
Fn588
Fn589
Fn590
Fn591
Fn592
Fn593
Fn594
Fn595
Fn598
Interface between CNC and PMC
ARE072#
ARE062#
ARE052#
ARE042#
ARE032#
ARE022#
ARE012#
ARE002#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE152#
#6
ARE142#
#5
ARE132#
#4
ARE122#
#3
ARE112#
#2
ARE102#
#1
ARE092#
#0
ARE082#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE232#
#6
ARE222#
#5
ARE212#
#4
ARE202#
#3
ARE192#
#2
ARE182#
#1
ARE172#
#0
ARE162#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE312#
#6
ARE302#
#5
ARE292#
#4
ARE282#
#3
ARE272#
#2
ARE262#
#1
ARE252#
#0
ARE242#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE073#
#6
ARE063#
#5
ARE053#
#4
ARE043#
#3
ARE033#
#2
ARE023#
#1
ARE013#
#0
ARE003#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE153#
#6
ARE143#
#5
ARE133#
#4
ARE123#
#3
ARE113#
#2
ARE103#
#1
ARE093#
#0
ARE083#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE233#
#6
ARE223#
#5
ARE213#
#4
ARE203#
#3
ARE193#
#2
ARE183#
#1
ARE173#
#0
ARE163#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE313#
#6
ARE303#
#5
ARE293#
#4
ARE283#
#3
ARE273#
#2
ARE263#
#1
ARE253#
#0
ARE243#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE074#
#6
ARE064#
#5
ARE054#
#4
ARE044#
#3
ARE034#
#2
ARE024#
#1
ARE014#
#0
ARE004#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE154#
#6
ARE144#
#5
ARE134#
#4
ARE124#
#3
ARE114#
#2
ARE104#
#1
ARE094#
#0
ARE084#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE234#
#6
ARE224#
#5
ARE214#
#4
ARE204#
#3
ARE194#
#2
ARE184#
#1
ARE174#
#0
ARE164#
SP
SP
SP
SP
SP
SP
SP
SP
#7
ARE314#
#6
ARE304#
#5
ARE294#
#4
ARE284#
#3
ARE274#
#2
ARE264#
#1
ARE254#
#0
ARE244#
SP
SP
SP
SP
SP
SP
SP
SP
#7
#6
#5
#4
-OT3O#P
+OT3O#P
-OT2O#P
+OT2O#P
#3
OT12O#P
#2
+OT12O
#1
OT11O#P
#0
+OT11O
#P
#P
203
Interface between CNC and PMC
Fn599
Fn687
Fn708
Fn709
Fn710
Fn711
Fn712
Fn713
Fn714
Fn715
Fn716
Fn717
Fn718
204
B-64805EN/03
#7
#6
#5
#4
#3
#2
#1
#0
OTSWF
N#P
RTC3O#P
RTC2O#P
CTC3O#P
CTC2O#P
GISO#P
#7
SVMWS
8#SV
#6
SVMWS
7#SV
#5
SVMWS
6#SV
#4
SVMWS
5#SV
#3
SVMWS
4#SV
#2
SVMWS
3#SV
#1
SVMWS
2#SV
#0
SVMWS
1#SV
#7
RE08O#S
#6
RE07O#S
#5
RE06O#S
#4
RE05O#S
#3
RE04O#S
#2
RE03O#S
#1
RE02O#S
#0
RE01O#S
P
P
P
P
P
P
P
P
#7
RE16O#S
#6
RE15O#S
#5
RE14O#S
#4
RE13O#S
#3
RE12O#S
#2
RE11O#S
#1
RE10O#S
#0
RE09O#S
P
P
P
P
P
P
P
P
#7
RE24O#S
#6
RE23O#S
#5
RE22O#S
#4
RE21O#S
#3
RE20O#S
#2
RE19O#S
#1
RE18O#S
#0
RE17O#S
P
P
P
P
P
P
P
P
#7
RE32O#S
#6
RE31O#S
#5
RE30O#S
#4
RE29O#S
#3
RE28O#S
#2
RE27O#S
#1
RE26O#S
#0
RE25O#S
P
P
P
P
P
P
P
P
#7
RE08O2#
#6
RE07O2#
#5
RE06O2#
#4
RE05O2#
#3
RE04O2#
#2
RE03O2#
#1
RE02O2#
#0
RE01O2#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE16O2#
#6
RE15O2#
#5
RE14O2#
#4
RE13O2#
#3
RE12O2#
#2
RE11O2#
#1
RE10O2#
#0
RE09O2#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE24O2#
#6
RE23O2#
#5
RE22O2#
#4
RE21O2#
#3
RE20O2#
#2
RE19O2#
#1
RE18O2#
#0
RE17O2#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE32O2#
#6
RE31O2#
#5
RE30O2#
#4
RE29O2#
#3
RE28O2#
#2
RE27O2#
#1
RE26O2#
#0
RE25O2#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE08O3#
#6
RE07O3#
#5
RE06O3#
#4
RE05O3#
#3
RE04O3#
#2
RE03O3#
#1
RE02O3#
#0
RE01O3#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE16O3#
#6
RE15O3#
#5
RE14O3#
#4
RE13O3#
#3
RE12O3#
#2
RE11O3#
#1
RE10O3#
#0
RE09O3#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE24O3#
#6
RE23O3#
#5
RE22O3#
#4
RE21O3#
#3
RE20O3#
#2
RE19O3#
#1
RE18O3#
#0
RE17O3#
SP
SP
SP
SP
SP
SP
SP
SP
B-64805EN/03
Fn719
Fn720
Fn721
Fn722
Fn723
Fn730
Interface between CNC and PMC
#7
RE32O3#
#6
RE31O3#
#5
RE30O3#
#4
RE29O3#
#3
RE28O3#
#2
RE27O3#
#1
RE26O3#
#0
RE25O3#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE08O4#
#6
RE07O4#
#5
RE06O4#
#4
RE05O4#
#3
RE04O4#
#2
RE03O4#
#1
RE02O4#
#0
RE01O4#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE16O4#
#6
RE15O4#
#5
RE14O4#
#4
RE13O4#
#3
RE12O4#
#2
RE11O4#
#1
RE10O4#
#0
RE09O4#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE24O4#
#6
RE23O4#
#5
RE22O4#
#4
RE21O4#
#3
RE20O4#
#2
RE19O4#
#1
RE18O4#
#0
RE17O4#
SP
SP
SP
SP
SP
SP
SP
SP
#7
RE32O4#
#6
RE31O4#
#5
RE30O4#
#4
RE29O4#
#3
RE28O4#
#2
RE27O4#
#1
RE26O4#
#0
RE25O4#
SP
SP
SP
SP
SP
SP
SP
SP
#7
TDA8#SV
#6
TDA7#SV
#5
TDA6#SV
#4
TDA5#SV
#3
TDA4#SV
#2
TDA3#SV
#1
TDA2#SV
#0
TDA1#SV
#7
#6
#5
#4
#3
#2
#1
#0
Fn767
205
Embedded ethernet function
2.
B-64805EN/03
Embedded ethernet function
The Ethernet port of each control unit is shown in Fig. 2-1.
Fig. 2-1 Ethernet ports of embedded Ethernet
Position
NAME
A
Stand-alone type control unit
B
LCD-mounted type control unit
C
Ethernet expansion board B
C1
Ethernet port 3 (et3: CS01C)
C2
Ethernet port 4 (et4: CS01D)
D
Interface board A
D1
Ethernet port 2 (et2: CS01B)
E
Main board
E1
Ethernet port 1 (et1: CS01A)
The default settings for each Ethernet port are as follows.
Ethernet port
Default IP address/subnet mask
Default use
et1:CS01A
192.168.1.1 / 255.255.255.0
Mixed
et2:CS01B
192.168.123.1 / 255.255.255.0
Display
et3:CS01C
192.168.3.1 / 255.255.255.0
Mixed
et4:CS01D
192.168.4.1 / 255.255.255.0
Mixed
NOTE
When changing the IP address of an Ethernet port, set it so that the network address (the address obtained by taking
the logical AND of the IP address and subnet mask) of each Ethernet port is different.
Example: It is not possible to configure as follows.
If Ethernet port 1 (et1) has IP address (192.168.1.1) and subnet mask (255.255.255.0),
Even if you set IP address (192.168.1.3) and subnet mask (255.255.255.0) for Ethernet port 3 (et3), the configuration
cannot be completed because they are the same network address.
206
B-64805EN/03
Embedded ethernet function
Each Ethernet port can be assigned a use.
Use
Additional Information
Communication with the LCD control unit is established using FOCAS3 protocol.
Display
Information
Industrial
Mixed
Communication with external PCs connected to machine tools is established using FOCAS3 or SMB
protocols.
Communication with internal or external remote I/O (sensors and actuators) or PLCs of machine tools
is established using EtherNet/IP, PROFINET, or FL-net protocols.
Communication for both information and industrial purposes is established.
Fig. 2-2 Example of connection configuration and usage settings for each Ethernet port on a stand-alone type
control unit
Position
NAME
A
Machine tool
B
Remote I/O
C
Stand-alone type control unit
D
LCD control unit
E
External PC
F
Industrial
G
Display
H
Information
NOTE
The following settings are recommended for the each usage setting.
1. In cases where use is confirmed for either "Information" or "Industrial" purposes:
In the connection example above, et1 is designated for "Information" and et3 is designated for "Industrial".
2. In cases where it is not confirmed whether to use "Information" or "Industrial":
Specify "Mixed"
207
Embedded ethernet function
2.1.
Network settings screen
With this function, network settings can be configured to connect the CNC to external devices.
Displaying the Network Settings screen.
To display the Network Settings screen, follow these steps:
On the menu screen, press the [Network] icon.
The Network Settings screen is displayed.
208
B-64805EN/03
B-64805EN/03
Embedded ethernet function
NOTE
If an application other than the Network Settings screen is displayed, press the vertical soft key [Network Settings].
209
Embedded ethernet function
B-64805EN/03
Names and functions of each part of the Network Settings screen
Fig. 2.1-1 Names and functions of each part of the Network Settings screen
Table 2.1-1 Names and functions of each part of the Network Settings screen
Position
Name of controls
Description
A
Screen Name Display Pane
Displays the name of the screen.
B
Category Selection Pane
Displays communication-related settings in a tree format.
C
Network Settings Pane
D
Guidance Message Display Pane
Displays the screen corresponding to the item selected in the
Category Selection Pane.
Displays a message in response to an operation.
Soft keys on the Network Settings screen
Vertical soft keys
Vertical soft keys display soft keys for transitioning to other screens. Pressing each soft key switches to the
corresponding screen.
Soft keys
Network Settings
Network Log
Industrial network
Messages
Setup & Machining
Menu
210
Operation when selected
The Network Settings screen is displayed.
The Network Log screen is displayed.
The Industrial Network screen is displayed.
Information Center is displayed.
The Setup & Machining screen is displayed.
The iHMI2 menu screen is displayed.
B-64805EN/03
Embedded ethernet function
Information displayed on the Network Settings screen
The Network Settings screen consists of a Category Selection Pane and a Network Settings Pane. The information
displayed for each is as follows.
Category Selection Pane
The Category Selection Pane displays network-related settings.
By selecting a category, a list of settings will be displayed in the Network Settings Pane.
Table 2.1-2 Category Selection Pane
No.
Selected Category
1
Control unit: Host Name @
Domain Name
Basic
Ethernet
Name Settings display (control
unit)
Basic Settings display (control
unit)
3
(etN:XXXXX)
4
FOCAS3 Server
Ethernet Settings display (control
unit)
Port Settings display
5
Advanced
Advanced Settings display
6
DNS Server
7
Routing
DNS Server Settings display
(control unit)
Routing display
8
(etN:XXXXX)
Routing Settings display
9
SMB Server
10
SMB Client
11
Display unit: Host
Name@Workgroup Name
SMB Server Settings display
(control unit)
SMB Client Settings display
(control unit)
Name Settings display (display
unit)
12
Ethernet
Ethernet display (display unit)
13
(etN:XXXXX)
14
SMB Server
Ethernet Settings display (display
unit)
SMB Server Settings display
(display unit)
2
Displayed screen
Description
Set the CNC's Host Name and
Domain Name.
A list of setting values that are
essential for building a network
can be checked.
Set individual Ethernet ports.
Set the TCP port number for
FOCAS3 communication.
A list of optional setting values
related to the network can be
checked.
Set preferred and alternative
DNS servers.
A list of Ethernet gateways can
be checked.
Set routing for Ethernet ports
Set up the SMB Server for CNC.
Set up the SMB Client for CNC.
Set the Host Name and
Workgroup Name for the display
unit.
A list of Ethernet port settings for
the display unit can be checked.
Set individual Ethernet ports.
Set up the SMB Server for the
display unit.
Horizontal soft keys
Selecting categories 1 to 10 will display the following horizontal soft keys.
Table 2.1-3 Horizontal soft keys when selecting a category on the Category Selection Pane
Soft keys
Details
ping
Status
Reflect
Cancel
Update
Operation when selected
The Detailed Information window for the selected category is displayed.
The ping window is displayed.
The Status Confirmation window is displayed.
Reflects set values in the CNC.
Depending on the changed setting, a CNC restart may be required.
The change in the set value will be canceled.
Updates the contents displayed on the screen.
211
Embedded ethernet function
B-64805EN/03
Selecting categories 11 to 13 will display the following horizontal soft keys.
Table 2.1-4 Horizontal soft keys when selecting a category on the Category Selection Pane on the display unit
Soft keys
Details
Reflect
Cancel
Update
Operation when selected
The Detailed Information window for the selected category is displayed.
Reflects set values in the CNC.
Depending on the changed setting, a CNC restart may be required.
The change in the set value will be canceled.
Updates the contents displayed on the screen.
Selecting category 14 will display the following horizontal soft keys.
Table 2.1-5 Horizontal soft keys when selecting a category on the Category Selection Pane on the display unit
(display unit SMB server)
Soft keys
Details
Folder path
Settings
Access Setting
Unsharing
Add Shares
Update
Operation when selected
The Detailed Information window for the selected category is displayed.
The full path of the folder where the SMB server is set is displayed.
The Settings window is displayed.
The Access Setting window is displayed. Cannot be selected without administrator privileges.
The Unsharing window is displayed. Cannot be selected without administrator privileges.
The Add Shares window is displayed. Cannot be selected without administrator privileges.
Updates the contents displayed on the screen. Cannot be selected without administrator
privileges.
■Changing values
To reflect the values, press the [Reflect] key after editing the values on the various setting screens described below.
Switching categories without pressing the [Reflect] key will cancel the input operation.
The background color of the input field will change to the following colors depending on the operation status.
Fig. 2.1-2 Background color of input field
Table 2.1-6 Background color of input field
212
B-64805EN/03
Position
Embedded ethernet function
State
A
Normal
B
Not reflected
C
Reflect failed
Description
This is a state "other" than not yet reflected or input failed.
The background color of the input field will be displayed in white.
Displays the current value
The settings have been successfully reflected
After inputting the data, the [Reflect] key has not been pressed.
The background color of the input field will be displayed in yellow.
The value will not reflect in the CNC unless the [Reflect] key is pressed.
Pressing the [Cancel] key will return the value to what it was before the input.
To release the not reflected state, perform the following operation.
Press the [Reflect] key
Press the [Cancel] key
Change the selected category
The [Reflect] key operation has failed.
The background color of the input field will be displayed in red.
The reason for the failure to reflect the settings in the Guidance Message Display
Pane will be displayed.
To release the reflect failed state, perform the following operation.
Change the input value
Press the [Cancel] key
Change the selected category
If the settings prevent the screen from displaying properly, pressing the [Reflect] key will show a notice message
window.
After agreeing to the notice message, press the [OK] key to apply the settings.
Fig. 2.1-3 Notice window
Network Settings Pane
A list of the values belonging to the category selected in the Category Selection Pane is displayed.
213
Embedded ethernet function
B-64805EN/03
Changing the name setting of the CNC (Name Settings display (control unit))
Select "Control Unit: Host Name@Domain Name" in the Category Selection Pane to display the Name Settings
display.
Set the control unit's Host Name and Domain Name.
Fig. 2.1-4 Name Settings display (control unit)
Table 2.1-7 Name Settings display (control unit)
Position
NAME
A
Host Name
B
Domain Name
Description
Set the Host Name (name that identifies a computer on a network) of the CNC.
Specify the Host Name of 63 characters or less.
Set the Domain Name (name used to identify a network) to which the CNC
belongs. Specify the Host Name and Domain Name that together are 253
characters or less.
When selecting positions A or B, in addition to the Table 2.1-3, the following horizontal soft keys can be selected.
Soft keys
Clear
Operation when selected
When the soft key is pressed, the input field becomes blank and the background color
becomes the not reflected color.
Pressing the [Reflect] key in this state will clear (unset) the settings.
■Setting example
An example of the Host Name, Domain Name, and label are as follows.
214
B-64805EN/03
Embedded ethernet function
Note that only alphanumeric characters (A-Z, a-z, 0-9), hyphens (-) and periods (.) can be used, and there are some
inputs that cannot be set.
Position
Name
In reference figure
A
Host Name
www
B
Domain Name
example.co.jp
C
Label
example and, co, jp
Input that cannot be set
(-) hyphen at the beginning
or end
(.) period at the beginning or
end
Consecutive periods (.)
Number of characters
63 characters or less
Host Name and Domain
Name at 253 characters or
less
63 characters or less for
each label
Checking the basic settings (Basic Settings display (control unit))
This is displayed by selecting "Basic" and "Ethernet" in the control unit of the Category Selection Pane.
The following values can be checked in a list as basic settings for the network.
• Default gateway value for the control unit
• Usage on the control unit
• IP address of the Ethernet ports on the control unit
• Subnet mask of the Ethernet ports on the control unit
Fig. 2.1-5 Basic Settings display (control unit)
215
Embedded ethernet function
B-64805EN/03
Table 2.1-8 Basic Settings display (control unit)
Position
Name
Description
A
Default Gateway Destination Port
B
Default Gateway IP Address
Check the name of the Ethernet port for which the default gateway is
set.
If the Default Gateway has not been set, "No Set" will be displayed.
The control unit has one default gateway within the control unit.
Check the IP address value.
C
et1: CS01A Usage
D
et1: CS01A IP Address
E
et1: CS01A Subnet Mask
Check the use of the Ethernet port.
The number of Ethernet ports on the control unit will be displayed on
the screen.
Check the IP address value set for the Ethernet port.
The value of the IP address is displayed on the screen in the number
of Ethernet ports in the control unit.
Check the subnet mask value set for the Ethernet port.
The value of the subnet mask is displayed on the screen for the
number of Ethernet ports on the control unit.
Configuring Ethernet ports (Ethernet settings display (control unit))
Select "Ethernet / etN:XXXXX (Ethernet Port Number: Connector Name)" in the Category Selection Pane to display it.
Set the IP address and subnet mask for the selected Ethernet port.
Fig. 2.1-6 Ethernet Settings display (control unit)
Table 2.1-9 Ethernet Settings display (control unit)
Position
216
Name
Description
A
Ethernet Port Number
Check the number of the Ethernet port.
B
Connector Name
Check the Connector Name.
C
MAC Address
Check the MAC address set for the Ethernet port.
B-64805EN/03
Embedded ethernet function
Position
Name
Description
D
Usage
E
Comment
F
IP Auto allocate
G
IP Address
Set the use of the Ethernet port by entering a number between 0 and
3.
0: Not used
1: Info
2: Ind.
3: Info. and Ind.
Set any comment for each Ethernet port.
Set using an ASCII character string.
Set the method for obtaining the IP address by entering a number
between 0 and 1.
0: Manual
1: Auto
When "Manual" is selected, the "IP Address" and "Subnet Mask" can
be set on the screen.
When "Auto" is selected, the IP address value will be obtained from
the DHCP server. At this time, the input forms for "IP Address" and
"Subnet Mask" will be grayed out and will no longer accept input.
Check the IP Address.
H
Subnet Mask
Set the Subnet Mask.
I
Default Gateway
Set the Default Gateway.
When selecting position D, in addition to the Table 2.1-3, the following horizontal soft keys can be selected.
Soft keys
0: Not used
1: Info
2: Ind.
3: Info. and Ind.
Operation when selected
0 (Not used) is entered for [Usage].
1 (Info) is entered for [Usage].
2 (Ind.) is entered for [Usage].
3 (Info. and Ind.) is entered for [Usage].
When selecting position F, in addition to the Table 2.1-3, the following horizontal soft keys can be selected.
Soft keys
0: Manual
1: Auto
Operation when selected
0 (Manual) is entered in [IP Auto allocate].
1 (Auto) is entered in [IP Auto allocate].
NOTE
1. If the usage is "Info", IP Auto allocate can be set to "Auto".
2. If IP Auto allocate is set to "Auto", the usage cannot be changed from "Info" to "Ind." or "Info. and Ind.". Set IP
Auto allocate to "Manual" and the usage to "Ind." or "Info. and Ind.".
3. The default gateway cannot be set for each Ethernet port. One default gateway can be set for the CNC control
unit.
When setting the Default Gateway, the IP address of the Default Gateway must be on the same network address
as the IP Address of the Ethernet port being configured.
(Example)
Set the Default Gateway (192.168.1.100) for et1 (192.168.1.1/255.255.255.0).
Setting the Default Gateway (192.168.100.100) for et1 (192.168.1.1/255.255.255.0) is not possible.
4. Note the following points regarding the default gateway when IP Auto allocate is set to "Auto".
When the IP address of the default gateway is distributed from the DHCP server:
The Default Gateway that has been set will be updated with the contents distributed from the DHCP server
(this will not be reflected in the settings at startup).
If IP Auto allocate for a single Ethernet port is set to "Auto", the Ethernet port that is set to automatic will
become the Ethernet port of the default gateway.
Example 1: If the Default Gateway (192.168.1.100) is set for et1 (192.168.1.1/255.255.255.0) and IP
Auto allocate is enabled for et3, the IP address of the default gateway distributed from the DHCP server
will be set for et3.
217
Embedded ethernet function
B-64805EN/03
NOTE
If IP Auto allocate for multiple Ethernet ports is set to "Auto", it is not possible to specify which Ethernet
port should be the default gateway.
Example 2-1: If et1 and et3 are set to Auto, and communication occurs in the order of DHCP server,
et1, et3, then et3 will become the Ethernet port for the default gateway.
Example 2-2: If et1 and et3 are set to Auto, and communication occurs in the order of DHCP server,
et3, et1, then et1 will become the Ethernet port for the default gateway.
When the IP address of the default gateway is not distributed from the DHCP server:
The default gateway that has been set remains unchanged.
Setting the port number for the FOCAS3 server (Port Settings display)
Select "FOCAS3 Server" in the Category Selection Pane to display it.
Set the TCP port number used for FOCAS3 communication.
Fig. 2.1-7 Port Settings display
Table 2.1-10 Port Settings display
Position
A
Name
Port Number
Description
Set the TCP port number for the FOCAS3 server.
Checking the advanced settings (Advanced Settings display)
Select "Advanced" in the Category Selection Pane to display it.
Check the settings for the advanced settings for the network.
218
B-64805EN/03
Embedded ethernet function
Fig. 2.1-8 Advanced Settings display
Table 2.1-11 Advanced Settings display
Position
Name
A
Preferred DNS Server
Alternate DNS Server
CS01A: Destination 1 Destination
IP Address
B
C
CS01A: Destination 2 Destination
IP Address
Description
The IP addresses of the preferred and alternate DNS servers are
displayed.
The Destination IP Address of Destination 1 is displayed.
The Destination IP Address for Destination 1 is displayed on the
screen in the number of control unit Ethernet ports.
The Destination IP Address of Destination 2 is displayed.
The Destination IP Address for Destination 2 is displayed on the
screen in the number of control unit Ethernet ports.
Set the DNS server address (DNS Server Settings display (control unit))
Select "DNS Server" in the Category Selection Pane to display it.
With this display, set the IP addresses of the Preferred DNS Server and the Alternate DNS Server.
219
Embedded ethernet function
B-64805EN/03
Fig. 2.1-9 DNS Server Settings display (control unit)
Table 2.1-12 DNS Server Settings display (control unit)
Position
Name
A
Preferred DNS Server
B
Alternate DNS Server
Description
Set the IP address of the Preferred DNS Server.
Leave the input fields blank to leave the Preferred DNS Server unset.
Set the IP address of the Alternate DNS Server.
Leave the input fields blank to leave the Preferred DNS Server unset.
NOTE
Even if the IP address of the DNS server is distributed from the DHCP server, it will not be reflected in the CNC, so set
it according to your network environment.
Checking the communication path in a list (Routing display)
Select "Routing" in the Category Selection Pane to display it.
Check the Routing settings for all Ethernet ports on the control unit in a list.
220
B-64805EN/03
Embedded ethernet function
Fig. 2.1-10 Routing display
Table 2.1-13 Routing display
Position
Name
A
Destination IP Address (CSXXX:
Destination 1)
B
Destination IP Address (CSXXX:
Destination 2)
Description
Check the gateway settings for Destination 1 for each Ethernet port
(etN:XXXXX).
The Destination IP Address for Destination 1 is displayed on the
screen in the number of control unit Ethernet ports.
Check the gateway settings for Destination 2 for each Ethernet port
(etN:XXXXX).
The Destination IP Address for Destination 2 is displayed on the
screen in the number of control unit Ethernet ports.
Setting the communication path (Routing Settings display)
Select "Routing / etN:XXXXX (Ethernet Port Number: Connector Name)" in the Category Selection Pane to display it.
Set Routing (path) for the selected Ethernet port.
221
Embedded ethernet function
B-64805EN/03
Fig. 2.1-11 Routing Settings display
Table 2.1-14 Routing Settings display
Position
Name
Description
A
Destination N / Destination IP Address
B
Destination N / Subnet Mask
Set the destination network address or the destination
host address.
Set the Subnet Mask for the destination network.
C
Destination N / Gateway IP
Set the IP address of the forwarding gateway.
When selecting positions A to C, in addition to the Table 2.1-3, the following horizontal soft keys can be selected.
Soft keys
Clear
Operation when selected
When the soft key is pressed, the input field becomes blank and the background color
becomes the not reflected color.
Pressing the [Reflect] key in this state will clear (unset) the settings.
■Setting example
The following is an example of Routing settings for the following network configuration.
222
B-64805EN/03
Position
Embedded ethernet function
Name
Description
A
Office area
Office with network address 172.16.0.0
A1, A2
Office PC
PC for creating machining programs, etc.
B
Server area
Server room with network address 192.168.100.0
B1
DNS server
C
Machining area
Preferred DNS Server 192.168.100.120
Alternate DNS Server 192.168.100.121
Machining shop floor with network address 192.168.1.0
C1
CNC control unit
CNC control unit where IP address of Ethernet port 1 is 192.168.1.1
R1
Office area router
R2
Server area router
Router that relays between the office area with the network address
172.16.0.0 and the machining area with the network address
192.168.1.0
Router that relays between the server area with the network address
192.168.100.0 and the machining area with the network address
192.168.1.0
CNC control unit setting example 1:
• Default gateway: R2 is the default gateway
•
192.168.1.254 is set for et1
• Routing: Set the destination by network address
•
Destination IP Address of Destination 1 of et1: 172.16.0.0
223
Embedded ethernet function
B-64805EN/03
•
Subnet Mask of Destination 1 of et1: 255.255.0.0
•
Gateway IP of Destination 1 of et1: 192.168.1.253
Communication to the destination IP addresses 172.16.10.10 and 172.16.10.20 sent by the CNC control unit matches
the routing settings, so it is sent to the office PC (A1) and office PC (A2) via the relay of the gateway address (office
area router) of the destination.
CNC control unit setting example 2:
• Default gateway: R2 is the default gateway
•
192.168.1.254 is set for et1
• Routing: Set the destination by host address
•
Destination IP Address of Destination 1 of et1: 172.16.10.10
•
Subnet Mask of Destination 1 of et1: 255.255.255.255
•
Gateway IP of Destination 1 of et1: 192.168.1.253
Communication to the destination IP address 172.16.10.10 sent by the CNC control unit matches the routing settings,
so it is sent to the office PC (A1) via the relay of the gateway address (office area router) of the destination.
Communication to the destination IP address 172.16.10.20 sent by the CNC control unit does not match the Routing
settings, so it is sent to the default gateway. The default gateway is discarded because there is no destination.
Configuring the SMB Server (SMB Server Settings display (control unit))
Select "SMB Server" in the Category Selection Pane to display it.
Set up to five SMB Server information.
Fig. 2.1-12 SMB Server setting display (control unit)
Table 2.1-15 SMB Server setting display (control unit)
Position
A
224
Name
SMB Server N / Shared Folder
Description
Set the Shared Folder.
B-64805EN/03
Position
Embedded ethernet function
Name
Description
B
SMB Server N / Shared Name
Set the Shared Name.
C
SMB Server N / Encryption
Set to Hidden or Open.
When selecting positions A or B, in addition to the Table 2.1-3, the following horizontal soft keys can be selected.
Soft keys
Clear
Settings
Operation when selected
When the soft key is pressed, the input field becomes blank and the background color
becomes the not reflected color.
Pressing the [Reflect] key in this state will clear (unset) the settings.
The Settings window is displayed.
When selecting position C, in addition to the Settings and Table 2.1-3, the following horizontal soft keys can be
selected.
Soft keys
0: Open
1: Hidden
Operation when selected
0 (Open) is entered in [Encryption].
1 (Hidden) is entered in [Encryption].
Configuring the SMB Client (SMB Client Settings display (control unit))
Select "SMB Client" in the Category Selection Pane to display it.
Set up to three SMB Client information.
The SD card in the display unit is set to NET1 as the default setting.
Fig. 2.1-13 SMB Client Settings display (control unit)
225
Embedded ethernet function
B-64805EN/03
Table 2.1-16 SMB Client Settings display (control unit)
Position
Name
A
File Share Destination
B
User Name
C
Password
D
Domain Name
Description
Set the communication partner (SMB server) for the file sharing
function using either a host name or IP address and shared folder
address.
Set the User Name for logging in to the communication partner (SMB
server) of the file sharing function.
Set the password for logging in to the communication partner (SMB
server) of the file sharing function. The entered string will be displayed
with "・".
Set the domain information for the communication partner (SMB
server) of the file sharing function.
When selecting positions A, B, or D in addition to the Table 2.1-3, the following horizontal soft keys can be selected.
Soft keys
Clear
Operation when selected
When the soft key is pressed, the input field becomes blank and the background color
becomes the not reflected color.
Pressing the [Reflect] key in this state will clear (unset) the settings.
When selecting position C, the following horizontal soft keys can be selected in addition to the above.
Soft keys
Show Password (* 1)
Hide Password (* 1)
Operation when selected
The password is displayed.
The password is masked.
* 1 Press the key to switch.
Changing the name setting of the display unit (Name Settings display (display unit))
Select "Display Unit: Host Name@Domain Name, Workgroup Name" in the Category Selection Pane to display the
Name Settings display.
In this display, you can set the host name, domain name, and workgroup name of the display unit.
226
B-64805EN/03
Embedded ethernet function
Fig. 2.1-14 Name Settings display (display unit)
Table 2.1-17 Name Settings display (display unit)
Position
Name
A
Host Name
B
Workgroup Name
Description
Displays the host name (name that identifies a computer on a network)
of the display unit.
Displays the name of the workgroup to which the display unit belongs.
Checking Ethernet settings (Ethernet display (display unit))
Select "Ethernet" under "Display: " in the Category Selection Pane to display it.
This display allows checking the following values in a list.
• Default gateway of the display unit
• IP address of the Ethernet ports on the display unit
• Subnet mask of the Ethernet ports on the display unit
227
Embedded ethernet function
B-64805EN/03
Fig. 2.1-15 Ethernet display (display unit)
Table 2.1-18 Ethernet display (display unit)
Position
Name
Description
A
et1: Connector Name IP Address
B
et1: Connector Name Subnet
Mask
C
Default Gateway IP Address
Check the IP Address set for the port.
The value of the IP address is displayed on the screen in the number
of Ethernet ports in the control unit.
Check the Subnet Mask set for the port.
The value of the subnet mask is displayed on the screen for the
number of Ethernet ports on the control unit.
Check the Default Gateway IP address.
Configuring Ethernet ports (Ethernet settings display (display unit))
Select etN:XXXXX (Ethernet Port Number: Connector Name) in the Category Selection Pane to display it.
This display allows configuring the selected Ethernet port.
228
B-64805EN/03
Embedded ethernet function
Fig. 2.1-16 Ethernet Settings display (display unit)
Table 2.1-19 Ethernet Settings display (display unit)
Position
Name
Description
A
Ethernet Port Number
Check the Ethernet port number.
B
Connector Name
Check the name of the connected connector.
C
MAC Address
Check the MAC address set for the Ethernet port.
D
IP Auto allocate
Set the method for obtaining the IP address by entering a number
between 0 and 1.
0: Manual
1: Auto
E
IP Address
When "Manual" is selected, the "IP Address" and "Subnet Mask" can
be set on the screen.
When "Auto" is selected, the IP address value will be obtained from
the DHCP server. At this time, the input forms for "IP Address" and
"Subnet Mask" will be grayed out and will no longer accept input.
Check the IP Address.
F
Subnet Mask
Set the Subnet Mask.
G
Default Gateway
H
DNS Servers Auto Configuration
Set the Default Gateway.
In the display unit, set a separate default gateway for each Ethernet
port.
Set the method for obtaining the DNS server by entering a number
between 0 and 1.
0: Manual
1: Auto
The DNS server can be changed when "IP Auto allocate" is set to
"Auto".
229
Embedded ethernet function
Position
B-64805EN/03
Name
Description
If "IP Auto allocate" is set to "Manual", the DNS server will always be
set manually.
I
Preferred DNS Server
If "Auto" is selected, the DNS server address will be automatically
obtained from the DHCP server. At this time, the input forms for
"Preferred DNS Server" and "Alternate DNS Server" will be grayed out
and will no longer accept input.
When "Manual" is selected, the "IP Address" and "Subnet Mask" can
be set on the screen.
Set the Preferred DNS Server.
J
Alternate DNS Server
Set the Alternate DNS Server.
When selecting position D or H, in addition to the horizontal soft keys of Table 2.1-4, the following horizontal soft keys
can be selected.
Soft keys
0: Manual
1: Auto
Operation when selected
0: Manual is entered for "IP Auto allocate".
1: Auto is entered for "IP Auto allocate".
Configuring the SMB Server (SMB Server Settings display (display unit))
Select "SMB Server" of the display unit in the Category Selection Pane to display it.
In this display, create an SMB Server (shared folder) for a specific folder on the storage device (internal storage, SD
card, USB memory) connected to the display unit.
In addition, the SMB server created in the SMB Server Settings display can be deleted and configured.
Fig. 2.1-17 SMB Server setting display (control unit)
230
B-64805EN/03
Embedded ethernet function
Table 2.1-20 SMB Server setting display (control unit)
Position
Name
A
SMB Server
B
Folder path
C
Shared Name
D
Optional Description
Description
The SMB Server string and serial number are displayed.
The maximum number of SMB servers that can be handled on the network
settings screen is five, and if the number of registered SMB servers is less than
five, the string "Not used" will be displayed.
If six or more SMB servers are registered, up to five of them will be displayed on
the screen in order of recognition.
The path of the folder registered as an SMB Server is displayed.
If the character string does not fit, the folder location will be displayed with
backward omission.
The shared name for accessing the SMB Server is displayed.
The shared name must be registered as a unique name on the display unit.
The description of the SMB Server that the cursor is pointing to on the screen is
displayed.
The description can display the text of "message.txt" placed directly under the
SMB Server, and if message.txt does not exist, the message 'There is no
"message.txt" in the shared folder.' will be displayed.
Setting SMB functions
Sets the SMB client and SMB server functions of the CNC.
For the Setting screen of the control unit, see Fig. 2.1-13, Fig. 2.1-12. For the Setting screen of the display unit, see Fig.
2.1-21.
SMB client functions
Fig. 2.1-18 Example of SMB client functions
Position
Name
Description
A
Machine tool
Example of a machine tool with a stand-alone type control unit
B
Stand-alone type control unit
CNC control unit
C
LCD control unit
CNC display unit
D
External PC
External PC connected by the CNC control unit.
E
SMB client
SMB client function for the CNC control unit
F
SMB Server
SMB server connected by the CNC control unit
231
Embedded ethernet function
Position
B-64805EN/03
Name
G
Data output
H
Data input
Description
Data output from the CNC control unit
Example: Data output to LCD control unit
Data input to the CNC control unit
Example: Data input from an LCD control unit or external PC
By setting the file share destination, the storage media of an external PC can be used as extended program memory.
After setting, the NC program runs on the external PC.
By default, the SD card in the display unit is registered in NET1.
■Setting example
The following is an example of how to add a destination.
[CNC]
NET2 File Share Destination ://192.168.1.100/NCPROG
NET2 User Name :user_id
NET2 Password :password
NET2 Domain Name :WORKGROUP
* For user_id and password, specify the account set on the destination external PC.
[External PC]
Enter the following command from PowerShell.
$ net share NCPROG=E:\NCPROG /GRANT:everyone,FULL
* Set the shared folder for the external PC to the parent folder of the "EXT_MEM" and "NC_DATA" folders.
Set the shared name and folder path according to the environment.
Settings can be configured through Explorer. In this case, both read and write permissions are required.
Example: <NCPROG>: Target folder for shared folder settings
┠ <EXT_MEM>: NC program folder
┗ <NC_DATA>: Other than above
For information on how to input the NC program from an external PC into the extended program memory of the
external PC, refer to the "Data input/output" section of "Series 500i-A MAINTENANCE MANUAL" (B-64805EN).
SMB server functions
Fig. 2.1-19 Example of SMB server functions
232
B-64805EN/03
Position
Embedded ethernet function
Name
Description
A
Machine tool
Example of a machine tool with a stand-alone type control unit
B
Stand-alone type control unit
CNC control unit
C
LCD control unit
CNC display unit
D
External PC
External PC connected by the CNC control unit.
E
SMB Server
SMB server function of the CNC control unit
F
SMB client
SMB client function connecting to the CNC control unit
G
Data input
H
Data output
I
Drag & Drop
Data input to the CNC control unit
Example: Inputting NC programs from an external PC
Data output from the CNC control unit
Example: Inputting NC programs to an external PC
Example of file operations by an external PC
The SD card of the CNC can be used as extended program memory.
In addition, setting the CNC's SD card to a shared folder enables the transfer of NC programs created on an external
PC to the CNC. After the transfer, operate the program by selecting the main program on the Program Manager
screen.
For details on how to use the Program Manager screen, refer to the "MACHINING OPERATIONS" section of "Series
500i-A OPERATOR'S MANUAL" (B-64804EN).
For more information on NC programs, refer to the "Program structure" chapter in "Series 500i-A CNC
PROGRAMMING MANUAL" (B-64804EN-1).
■Setting example
The following shows a setting example.
[CNC]
SMB Server 1 Shared Folder ://EXT_MEM/USER/
SMB Server 1 Shared Name :USER
SMB Server 1 Encryption :Hidden
[External PC]
Enter the following command from PowerShell.
$ net use Z: \\192.168.1.1\USER password /user:user_id
* The password and user_id are the user ID and password set in the user authentication function.
Z: is optional. Specify a drive name that is not being used on the external PC.
■Operation example
The NC program on the external PC is transferred to the CNC (external PC → CNC).
$ copy O1000.TXT Z:\PATH1
In the above command example, the NC program is transferred to the PATH1 folder in the USER folder of the CNC.
Transfer is also possible using drag & drop operations in Explorer.
The NC program for the CNC is transferred to an external PC (CNC → external PC).
$ copy Z:\PATH1\O1000 .\O1000.TXT
In the above command example, the NC program will be obtained as O1000.TXT in the current location folder on the
external PC.
Transfer is also possible using drag & drop operations in Explorer.
Note that the following restrictions apply to file transfers.
233
Embedded ethernet function
B-64805EN/03
NOTE
1.
2.
3.
4.
5.
6.
7.
8.
9.
When executing commands, use PowerShell instead of the command prompt that comes with Windows OS.
Multibyte characters such as Japanese will cause an error in the file name.
The maximum file size that can be sent and received is 2GB per file.
If the NC program is write-protected (bit 2 of parameter No. 3201=0), an error will occur if there is an NC program
with the same name. Delete the NC program manually before transferring it.
It is not possible to transfer multiple files simultaneously. Execute file transfer operations one file at a time.
If an error occurs during file transfer, the NC program in the middle of transfer may remain in the CNC. In that
case, delete it manually.
Do not open the NC program in the CNC directly by double-clicking it in Explorer, etc.
When editing an NC program, transfer it to an external PC, edit and save it, and then transfer the file again.
After transferring the NC program for the CNC to an external PC, opening it will result in multiple blank characters
being inserted at the end of the file due to the difference in file format. However, this is not a problem.
It is possible to switch so that empty characters are not inserted at the end of files using SMB maintenance
settings, but this will slow down the transfer.
In addition, the security settings for the SMB server of the CNC can be changed by adjusting the settings in the
Settings window.
Displaying the Settings window
The Settings window can be displayed by executing the following operations.
■For the SMB Server of the control unit
Display the SMB Server Settings display
Press the [Settings] key in the SMB Server Settings display.
The Settings window is displayed.
234
B-64805EN/03
Embedded ethernet function
■For the SMB Server of the display unit
Display the SMB Server Settings display (display unit)
Press the [Settings] key in the SMB Server Settings display (display unit).
235
Embedded ethernet function
The Settings window is displayed.
236
B-64805EN/03
B-64805EN/03
Embedded ethernet function
Names and functions of each part of the Settings window
■For the SMB Server of the control unit
Fig. 2.1-20 Names and functions of each part of the Settings window
Table 2.1-21 Names and functions of each part of the Settings window
Position
Name
A
Message Signing Policies
B
Server Encryption Settings
C
SMB1 Protocol-Connectivity
D
SMB Maintenance Setting
Description
A message signing policy can be chosen(* 1). The default is
"Enabled".
Enabled: The presence or absence of SMB signing is determined
according to the SMB signing settings of the SMB client (* 2)
Required: SMB signing are applied regardless of the SMB signing
settings of the SMB client (* 2)
Disabled: Does not require SMB signing (* 2) (* 3)
Server Encryption Settings can be set as desired. The default is "Each
SMB Server".
Each SMB Server: Linked to encryption settings for each shared
folder
All SMB Server: Encrypted communication is executed
regardless of the encryption settings for each shared folder.
If Each SMB Server is selected, set it using the "Fig. 2.1-12".
Selection of SMB1 Protocol-Connectivity is possible. The default is
"Not Connectable".
Not Connectable: SMB1 connections are not allowed.
Permission: SMB1 connections are allowed.
The SMB Maintenance setting can be set by entering a value. The
default is "0".
0: When transferring the NC program for the CNC to an external
PC, multiple blank characters will be inserted at the end of the file
due to the difference in file format (this is not a problem)
32768: This will prevent blank characters from being inserted at
the end of the file, but it will also slow down the transfer speed.
237
Embedded ethernet function
B-64805EN/03
* 1 Data tampering is detected by attaching a signature generated using a session key to the SMB communication
content.
Additionally, depending on the SMB server options in the control unit, attention must be paid to the settings and
version of the SMB client on the external PC.
SMB server options for the control unit
SMB client settings and versions
Message Signing Policies
(※ 2)(※ 3)
Server Encryption Settings: Hidden
SMB1 Protocol-Connectivity: Not Connectable
Windows 10 or later is required (SMB 3.11 or later)
Cannot connect with Windows XP and earlier.
* 2 If the SMB client is Windows 7 or later, it will be as follows.
SMB server settings for the control unit
Setting SMB client
Enabled (default)
Required
Disabled
Connection:
Possible
Signature:
None
Connection:
Possible
Signature: Yes
Signature request: Not required
(default)
Connection: Possible
Signature: None
Connection:
Possible
Signature: Yes
Signature request: Required
Connection: Possible
Signature: Yes
Connection:
Possible
Signature: Yes
* 3 If the SMB client is Windows XP, it will be as follows.
SMB server settings for the control unit
Setting SMB client
Enabled (default)
Required
Signature: Disabled
Signature request: Not required
(default)
Connection: Possible
Signature: None
Connection:
Possible
Signature: Yes
Signature: Disabled
Signature request: Required
Connection: Possible
Signature: Yes
Signature: Enabled
Signature request: Not required
Connection: Possible
Signature: Yes
Connection:
Possible
Signature: Yes
Connection:
Possible
Signature: Yes
Signature: Enabled
Signature request: Required
Connection: Possible
Signature: Yes
Connection:
Possible
Signature: Yes
Disabled
Connection:
Possible
Signature:
None
Connection:
Not possible
Signature: Connection:
Possible
Signature:
None
Connection:
Not possible
Signature: -
Note: Depending on the combination of SMB client settings and SMB server settings, it may not be possible to
connect.
238
B-64805EN/03
Embedded ethernet function
■For the SMB Server of the display unit
Fig. 2.1-21 Names and functions of each part of the Settings window (display unit)
Table 2.1-22 Names and functions of each part of the Settings window (display unit)
Position
Name
A
Message Signing Policies
B
Server Encryption Settings
C
SMB Maintenance Setting
Description
A message signing policy can be chosen. The default is "Disabled".
(※ 1)
Enabled: The presence or absence of SMB signing is determined
according to the SMB signing settings of the SMB client
Required: SMB signing are applied regardless of the SMB signing
settings of the SMB client
Disabled: Does not require SMB signing
Server Encryption Settings can be set as desired. The default is
"Unencrypted".
If "Encryption" is selected, the SMB client being connected to must
support SMB encrypted communication.
The SMB Maintenance setting can be set by entering a value. The
default is "0".
Entering a value other than 0 will not change the function.
* 1 Depending on the settings of the connecting SMB client, it will be as follows.
SMB server settings for the display unit
Setting SMB client
Signature request: Not required
Signature request: Required
Enabled
Required
Disabled (default)
Connection:
Possible
Signature:
None
Connection:
Possible
Signature: Yes
Connection:
Possible
Signature: Yes
Connection: Possible
Signature: None
Connection:
Possible
Signature: Yes
Connection: Possible
Signature: Yes
The horizontal soft keys on the Settings window are as follows.
239
Embedded ethernet function
B-64805EN/03
Table 2.1-23 Soft keys on the Settings window
Soft keys
Cancel
OK
Operation performed when pressed
Closes the Settings window.
Reflects the settings.
Adding SMB servers
A new SMB server can be added by following operations.
■For the SMB Server of the control unit
Set directly from the input fields in "SMB Server Settings (control unit)".
■For the SMB Server of the display unit
Set from the Add Shares window. The Add Shares window is displayed by pressing the [Add Share] key in the "SMB
Server Settings display (display unit)".
Fig. 2.1-22 Names and functions of each part of the Add Shares window
Table 2.1-24 Names and functions of each part of the Add Shares window
Position
240
Name
A
Potential SMB server settings
B
Server description
Description
A list of potential SMB servers that can be created in the display unit is
displayed.
After selecting a list, register the selected folder as an SMB server by
pressing the [Add] key.
The folders that can be registered as SMB servers from the Add
Shares window are limited to the "shareData" folder placed in a
specified location, the USB or SD card drive directly below, or the
folder set by the machine tool builder (*1).
The description of the SMB Server that the cursor is pointing to on the
screen is displayed.
B-64805EN/03
Position
Embedded ethernet function
Name
Description
The description can display the text of "message.txt" placed directly
under the SMB Server, and if message.txt does not exist, the message
'There is no "message.txt" in the shared folder.' will be displayed.
For information on how to set the folders (* 1) set by the machine tool builder, refer to the "iHMI2 SETUP
MANUAL".
Table 2.1-25 Soft keys on the Add Shares window
Soft keys
Folder path
Update
Add
Cancel
Operation performed when pressed
The full path of the folder where the SMB server is created is displayed.
Updates the contents of the Add Shares window.
If a new external USB device is plugged in while the window is open, make it appear on the
window by pressing the [Update] key.
The folder path selected in the Add Shares window is set as an SMB server.
Pressing the [Add] key will display a new Shared Name Settings window, allowing entry of a
shared name.
By setting the shared name and pressing the [OK] key, the SMB server will be added.
The Add Shares window is closed without adding an SMB server.
Deleting SMB servers
SMB server sharing can be canceled by following operations.
■For the SMB Server of the control unit
Delete the settings directly from the input fields in "SMB Server Settings (control unit)".
■For the SMB Server of the display unit
To unshare an SMB server, select the SMB server you want to unshare in the "SMB Server Settings display (display
unit)" and then press the [Unsharing] key.
Pressing the [Unsharing] key will display the Unsharing window.
The Unsharing window displays whether access to the shared folder is available and includes a confirmation
message asking if unsharing is desired.
241
Embedded ethernet function
B-64805EN/03
In the Unsharing window, press the [OK] key to unshare the selected SMB server.
Changing SMB server access permissions
Access permissions for SMB servers can be set by following operations.
■For the SMB Server of the control unit
There are no settings related to access permissions.
■For the SMB Server of the display unit
Set from the Access Permission window. The Access Setting window is displayed by selecting the desired SMB
server in the "SMB Server Settings display (display unit)" and then pressing the [Reflect] key.
Fig. 2.1-23 Names and functions of each part of the Access Setting window
242
B-64805EN/03
Embedded ethernet function
Table 2.1-26 Names and functions of each part of the Access Setting window
Position
Name
A
User List
B
Access Privileges
C
Server description
Description
Displays a list of groups and users who can connect to the target SMB
server.
Groups and users can be registered up to a maximum of 10 per SMB
server.
Set access permissions for the user account selected in the user list.
Group name: Set the name of the group or user that will be
granted access.
Full Control: Allows all operations, such as viewing, editing, and
executing files placed on the SMB server.
Read: Allows editing of files stored on the SMB server.
Write: Allows viewing of files stored on the SMB server.
The description of the SMB Server that the cursor is pointing to on the
screen is displayed.
The description can display the text of "message.txt" placed directly
under the SMB Server, and if message.txt does not exist, the message
'There is no "message.txt" in the shared folder.' will be displayed.
When the SMB server is added from the Add Shares window, by default, the Administrator will be given full
control access privileges.
When a shared folder with full control privileges granted to the Administrator is set in the "SMB Client Settings
display (Control Unit)", the "EXT_MEM" and "NC_DATA" folders will be created automatically.
Table 2.1-27 Soft keys on the Access Setting window
Soft keys
Operation performed when pressed
Delete
Deletes the access privileges of the user selected in the user list.
Pressing the [Delete] key will display a confirmation window, and pressing the [OK] key in the
confirmation window will delete the user.
0: Disabled
1: Enabled
Reflect
For access permission settings (Full Control, Enabled, Disabled), enter "0: Disabled" or "1:
Enabled" in the settings field.
Cancel
Close
Reflects the change in access privileges. Selecting another list or closing the window without
pressing the [Reflect] key will result in the changes to the access privileges being discarded.
Cancels the change in access privileges.
Closes the Access Setting window.
Sending a ping
Ping packets can be sent to any destination from the Ethernet port of the control unit.
Displaying the ping window
The ping window is displayed by following operations.
243
Embedded ethernet function
Press the [ping] key on the Network Settings screen.
The ping window is displayed.
244
B-64805EN/03
B-64805EN/03
Embedded ethernet function
Names and functions of each part of the ping window
Fig. 2.1-24 Names and functions of each part of the ping window
Table 2.1-28 Names and functions of each part of the ping window
Position
Name
A
Destination
B
Times
C
Execution result
D
Guidance message
Description
The destination for sending pings can be entered/displayed.
Any IP address or host name (example: www.example.com) can be
specified as the destination.
Specify the number of times to send a ping.
Specify the number of times from 1 to 10.
The default number of times ping is sent is four times.
Displays the following as the result of executing ping.
Destination address
Bytes Transmitted (fixed at 32 bytes)
Transmission result
A message will be displayed in response to the window operation.
The horizontal soft keys on the ping window are as follows.
Table 2.1-29 Soft keys on the ping window
Soft keys
Stop ping
Ping transmission
Close
Operation performed when pressed
Cancels the ping being sent.
Ping is transmitted.
Closes the ping window.
245
Embedded ethernet function
Sending a ping
The following operations can be performed in the ping window.
■Sending a ping
Input the ping destination.
Input the number of times.
Press the [Send ping] key.
The ping is sent and the results are displayed.
■Canceling sending a ping
Press the "Stop ping" key while sending a ping.
The ping transmission is canceled.
■Closing the ping window
Press the [Close] key.
Checking the communication status
The network communication status, such as the number of sent packets, can be checked.
Displaying the Status window
The Status window is displayed by following operations.
Press the [Status] key on the Network Settings screen.
246
B-64805EN/03
B-64805EN/03
Embedded ethernet function
The Status window is displayed.
Names and functions of each part of the Status window
247
Embedded ethernet function
B-64805EN/03
Fig. 2.1-25 Names and functions of each part of the Status window
Table 2.1-30 Names and functions of each part of the Status window
Position
A
Name
Port Number
B
Setting Item Name
C
Status
Description
The Ethernet port number being checked for communication status is
displayed.
When a window is drawn, the Ethernet port with the lowest number
among the available Ethernet port numbers is displayed.
The communication status description (header) is displayed.
The following communication status for the selected Ethernet port can
be checked.
Communication Rate
Number of Octets Sent
Sent Packet(s)
Number of Sent Packets Discarded
Number of Sent Packets Discarded Due To Errors
Number of Unicast Packets Sent
Packets Sent Via Multicast
Number of Broadcast Packets Sent
Number of Transmitted Packets with An Underflow Error
Number of Transmitted Packets with A Single Collision
Number of Transmitted Packets with Multiple Collisions
Number of Packets Sent with Late Collision Errors
Number of Packets Sent with Excessive Collision Error
Number of Octets Received
Received Packet(s)
Number of Received Packets Discarded
Number of Received Packets Discarded Due to Errors
Number of Received Packets of Unsupported Protocol
Number of Unicast Packets Received
Packets Received Via Multicast
Number of Packets Received by Broadcast
CRC(FCS) Number of Packets with Error Reception
248
B-64805EN/03
Position
Embedded ethernet function
Name
Description
Number of Packets Received with Runt Error
Number of Alignment Error Received Packets
The horizontal soft keys on the Status window are as follows.
Table 2.1-31 Soft keys on the Status window
Soft keys
et1
et2
et3
et4
Close
Operation performed when pressed
Displays the communication status of et1.
Displays the communication status of et2.
Displays the communication status of et3.
Displays the communication status of et4.
Closes the Status window.
Checking the detailed name
If the adapter name or host name is long, it may not be displayed in full.
The full name can be checked by using the Detail window.
Displaying the Detail window
The Detail window is displayed by following operations.
Press the [Detail] key on the Network Settings screen.
The Detail window is displayed.
249
Embedded ethernet function
Names and functions of each part of the Detail window
250
B-64805EN/03
B-64805EN/03
Embedded ethernet function
Fig. 2.1-26 Names and functions of each part of the Detail window
Table 2.1-32 Names and functions of each part of the Detail window
Position
Name
Selected Category
A
Description
The full name of the selected category name is displayed.
The horizontal soft keys on the Detail window are as follows.
Table 2.1-33 Soft keys on the Detail window
Soft keys
Close
2.2.
Operation performed when pressed
Closes the Detail window.
Network Log screen
Using this function allows the communication status log between external equipment and the CNC to be checked.
Displaying the Network Log screen
The Network Log screen is displayed by following operations.
On the menu screen, press the [Network] icon.
The Network Settings screen is displayed.
251
Embedded ethernet function
Press the [Network Log] key on the vertical soft keys.
The Network Log screen is displayed.
252
B-64805EN/03
B-64805EN/03
Embedded ethernet function
Names and functions of each part of the Network Log screen
Fig. 2.2-1 Names and functions of each part of the Network Log screen
Table 2.2-1 Names and functions of each part of the Network Log screen
Position
Name
Description
A
Log List Display Unit
A list of the log information held by the CNC control unit is displayed.
B
Detailed Information display pane
The full text of the message selected in the log list display pane is
displayed.
Soft keys on the Network Log screen
Vertical soft keys
Vertical soft keys display soft keys for transitioning to other screens. Pressing each soft key switches to the
corresponding screen.
Soft keys
Network Settings
Network Log
Industrial network
Messages
Setup & Machining
Menu
Operation when selected
The Network Settings screen is displayed.
The Network Log screen is displayed.
The Industrial Network screen is displayed.
Displays the message screen.
The Setup & Machining screen is displayed.
Displays the menu screen.
Horizontal soft keys
The functions that the Network Settings screen has are displayed as horizontal soft keys.
Soft keys
Info Log
Operation when selected
The contents of the screen display will be changed to log data related to Information networks.
253
Embedded ethernet function
Soft keys
Industrial Log
Top
Bottom
Log Clear
Log Stop (*1)
Log Resume (*1)
B-64805EN/03
Operation when selected
The contents of the screen display will be changed to log data related to Industrial networks.
The cursor will move to the top of the log data.
The cursor will move to the bottom of the log data.
Clears the log data stored in the CNC.
Be careful when clearing the log data, as it cannot be restored.
When the Network Log screen is displayed, the display is updated every two seconds, but
pressing the [Log Stop] or [Log Resume] key will stop/restart the display update of the log data.
[Log Stop]/[Log Resume] can be specified for each of the Info Log and the Industrial Log.
Pressing [Log Stop] will stop the display screen from updating, but the CNC side will continue
to obtain log data. Therefore, pressing the [Log Resume] key may result in the old log data
being overwritten by the new log data that has accumulated, causing the old log data to
disappear from the display.
*1 Press the key to switch.
NOTE
Log Clear
The selected log is cleared by pressing the [Log Clear] key on the Network Log screen.
Note that cleared logs cannot be restored.
Information displayed on the Network Log screen
Log data related to the network is displayed in a list. The log data is updated every two seconds.
Log data is displayed up to a maximum of 120 entries, with new log data added to the top of the list.
If the number of log data entries exceeds 120, the oldest log data at the bottom of the list will be deleted and new log
data will be added to the top of the list.
Fig. 2.2-2 Log List Display Unit
254
B-64805EN/03
Embedded ethernet function
Table 2.2-2 Log List Display Unit
Position
A
Name
Severity
Description
The severity of the log data is displayed. The following are the levels of severity
displayed.
Information: When processing starts or ends (normal system)
Warning: If an event occurs that is not an error, such as a retry
Error: In abnormal situations
Deadly: In the case of an error that requires a restart
B
Function
The module classification of the log data is displayed.
C
Messages
An overview of the log data is displayed.
D
Date
The date of the log data is displayed.
E
Time
The time of the log data is displayed.
F
Full message
The full message of the log data is displayed.
2.3.
Industrial Network Screen
You can check the status of Industrial Network devices.
Displaying the Industrial Network screen
To display the Network Settings screen, follow these steps:
On the menu screen, press the [Network] icon
The Network Settings screen is displayed.
Press the [Industrial Network] key on the Network Settings screen.
255
Embedded ethernet function
B-64805EN/03
The Industrial Network screen is displayed.
Names and functions of each part of the Industrial Network screen
The Industrial Network screen is made up of the Display Range Selection pane, Status Display pane, Message
Display pane, and Guidance Message Display pane.
The information displayed for each is as follows.
256
B-64805EN/03
Embedded ethernet function
Fig. 2.3-1 Names and functions of each part of the Industrial Network screen
Table 2.3-1 Names and functions of each part of the Industrial Network screen
Position
Name
A
Display Range Selection pane
B
Status Display pane
Description
You can select the range that includes the device numbers you want
to check from the list.
By selecting the target to display, the contents of the devices
belonging to the selected range will be displayed in the Status Display
pane.
The Display Range Selection pane contains up to 10 devices and
displays a list of 20.
The status of the devices included in the list selected in the Display
Range Selection pane is displayed.
Name
Port
Device name
State
Type
Description
The Ethernet port number (et1
to et4) to which the device is
connected is displayed.
If a PROFIBUS-DP board is
inserted, the option slot number
(slot1 to slot4) is displayed.
Displays the device name.
Displays the device status.
The status displayed are as
follows.
Running
Stopped
Error
Displays the device type.
The types displayed are as
follows.
If the device type is unknown, [--] will be displayed.
PROFINET_IO_MASTER
PROFINET_IO_SLAVE
257
Embedded ethernet function
Position
B-64805EN/03
Name
Description
PROFINET_IO_MODULE
PROFINET_IO_DEVICE
PROFINET_IO_SUBMOD
ULE
ETHERNET_IP_SCANNE
R
ETHERNET_IP_REMOTE
_ADAPTER
ETHERNET_IP_MODULE
ETHERNET_IP_LOCAL_A
DAPTER
FLNET_DEVICE
FLNET_SELF_NODE
FLNET_PARTICIPATING_
NODE
PROFIBUS_MASTER
PROFIBUS_SLAVE
PROFIBUS_DEVICE
PROFIBUS_MODULE
NOTE
The types of devices that are
displayed may be added or
changed.
C
D
Message Display pane
Guidance Message Display Pane
The message/device name of the selected Industrial Network
Communication Status is displayed.
You can switch between Diagnosis Info/Device Name by pressing the
[Message Switch] key.
Diagnosis Info: The diagnosis information for the device the cursor is
on is displayed.
Device Name: The device name of the device the cursor is on is
displayed.
Descriptions and warning messages are displayed according to the
results of the on-screen operations.
■Displayed guidance messages
Messages
Updated
Device configuration has
been changed
Description
Displayed when you press the
[Refresh] key.
This is displayed when the device
configuration of the industrial
network device is changed.
This message is displayed when
the following operations are
performed.
When you switch the selected
display range
When you press the [Refresh]
key
When the update is complete, the
cursor will be on [1-10] at the
beginning of the Display Range
Selection pane.
■Displayed warning messages
Messages
258
Description
B-64805EN/03
Embedded ethernet function
Position
Name
Description
No register information
This is displayed when there are no
registered cases of industrial
network devices.
When this warning message is
displayed, the cursor will move to
the first number [1-10] in the
Display Range Selection pane, and
the Status Display pane will be
empty.
Soft keys on the Industrial Network screen
Vertical soft keys
By pressing the vertical soft keys, you can switch the display to the screen corresponding to the soft key.
Soft keys
Network Settings
Network Log
Industrial network
Messages
Setup & Machining
Menu
Operation performed when pressed
The Network Settings screen is displayed.
The Network Log screen is displayed.
The Industrial Network screen is displayed.
Displays the message screen.
The Setup & Machining screen is displayed.
Displays the menu screen.
Horizontal soft keys
The functions that the Industrial Network Communication Status screen has are displayed as horizontal soft keys.
The string displayed on the horizontal soft keys depends on the selected language.
Soft keys
Update
Change Message
Operation performed when pressed
The information in the Status Display pane will be updated.
When the device configuration changes, the information in the Display Range Selection pane is
also updated.
The information in the Message pane will be replaced with the device name. Pressing it again
will switch to the message.
259
IV Fault handling
B-64805EN/03
1.
Troubleshooting
Troubleshooting
This chapter describes how to perform troubleshooting on the CNC side.
1.1.
Corrective action for failures
When a failure occurs, it is important to correctly grasp what kind of failure occurred and take appropriate action, to
promptly recover the machine. Check for the failure according to the following procedure :
1.1.1.
Investigating the Conditions under which Failure Occurred
• When and how many times (frequency of occurrences)
• With what operation
• What failure occurred
Investigate the above.
When the alarm issued is a system alarm, refer to "IV.1.22. System alarms(P.309)" to obtain system alarm
information.
• When did the failure occur?
•
What is the date and time when the malfunction occurred?
•
Occurred during operation? (how long was the operation?)
•
Occurred when the power was turned on?
•
Was there any lightening surge, power failure, or other disturbances to the power supply?
• How many times has it occurred?
•
Only once?
•
Occurred many times? (How many times per hour, per day, or per month?)
• What king of operation was performed when the failure occurred?
•
What was the NC mode when the failure occurred?
(Jog mode/memory operation mode /MDI mode /reference position return mode)
•
If during program operation,
Where in the program?
Which program No. and sequence No.?
What program?
Occurred during axis movement?
Occurred during the execution of an M/S/T code?
Failure specific to the program?
•
Does the same operation cause the same failure?
(Check the reproducibility of the failure.)
•
Occurred during data input/output?
263
Troubleshooting
B-64805EN/03
<Feed axes and spindles>
•
•
For a failure related to feed axis servo
●
Occurred at both low feedrate and high feedrate?
●
Occurred only for a certain axis? (In the case of a cable disconnection)
For a failure related to spindles
When did the failure occur? (during power-on, acceleration, deceleration, or constant rotation)
• What failure occurred?
•
Which alarm was displayed on the alarm display screen?
(Check the axis for which the alarm has occurred in the case of SV, OT, or SP alarms.)
•
Is the screen correct?
•
If machining dimensions are incorrect
●
How large are the incorrect dimensions?
●
Is the position display on the CRT correct?
●
Are the offsets correct?
• Other information
•
Is there a noise origin around the machine?
If the failure has not occurred frequently, the cause may be external noise to the power supply or inductive
noise on machinery cables. Are other machines or welders connected to the same power line?
If so, check if the other machines are related to the failure. (Check if noise comes from the other machines.)
•
Is any countermeasure for noise taken on the machine side? See "I.1.6. Cautions related to grounding and
noise(P.46)".
•
Check the following for the input power supply voltage:
●
Is there variation in the voltage?
●
Are the voltages different depending on the phase?
●
Is the standard voltage supplied?
•
How high is the ambient temperature of the control unit?
•
Has excessive vibration been applied to the control unit?
• When you contact FANUC service center, specify the following items:
•
Name of the CNC unit
•
Name of the machine tool builder and type of machine
•
Software series/version of the CNC
•
Specifications of the servo amplifier and motor (for a failure related to the servo)
•
Specifications of the spindle amplifier and spindle motor (in the case of a failure related to a spindle)
See the drawing issued by the machine-tool builder showing the locations of the CNC unit and
servo/spindle amplifiers.
FANUC uses the following specification codes:
•
Servo/spindle amplifiers: A06B-xxxx-Hxxx
•
Servo/spindle motors: A06B-xxxx-Bxxx
NOTE
The mark 'x' represents a number.
264
B-64805EN/03
1.2.
Troubleshooting
No manual operation nor automatic operation can be executed
Points
• When neither manual nor automatic operation is functioning, investigation is conducted according to this
procedure.
• Check whether position display is operating.
• Check CNC status display.
• Check CNC internal status using diagnosis function.
Causes and Countermeasures
■The position display (relative, absolute, machine coordinates) does not change
■Check the CNC status display. (Refer to " II.4. CNC state display(P.82)" for details.)
• Emergency stop status (Emergency stop signal is turned on)
If the status display shows
screen for the following signals:
, emergency stop signal is input. In this case, check
the PMC's signal status
*ESP=0 indicates that emergency stop signal is input.
Xn008
#7
#6
#5
#4
*ESP
Gn008
*ESP
#3
#2
#1
#0
• It is in a reset status
When RESET is displayed, the machine is in a reset status. Check the following signals using the PMC's signal
status screen:
1. An input signal from the PMC is turned on
When ERS is 1, external reset signal is input
When RRW is 1, reset & rewind signal is input.
Gn008
#7
ERS
#6
RRW
#5
#4
#3
#2
#1
#0
2. <RESET> key on the MDI unit is functioning
If the signal in the previous section 1 is off, the <RESET> key may be functioning. Check the contact of the
<RESET> key using a tester.
When it is abnormal, change the MDI unit.
• Check the status of mode selection
The operation mode status is displayed on the lower part of screen as follows:
If nothing is displayed, mode select signal is not input. Check the mode selection signal using the PMC's signal
status screen. (For details, refer to "II.4. CNC state display(P.82)".)
Display example:
JOG : Manual operation (JOG) mode
HND : Manual handle (MPG) mode
MDI : Manual data input mode (MDI)
MEM : Automatic operation (Memory) mode
EDIT : EDIT (Memory edit) mode
<Mode selection signal>
265
Troubleshooting
B-64805EN/03
#7
#6
#5
#4
#3
Gn043
MODE
Manual operation (JOG) mode
Manual handle (MPG) mode
Manual data input (MDI) mode
Automatic operation (Memory) mode
EDIT (Memory edit) mode
MD4
1
1
0
0
0
#2
MD4
#1
MD2
MD2
0
0
0
0
1
#0
MD1
MD1
1
0
0
1
1
■Check CNC diagnosis data No. 0000 and 1010
Check the items for which 1 is displayed.
DGN 0
CNC internal state 1
[Data type]
Bit path
Internal state when "1" is displayed
NAME
#
INPOSITION CHECK
0
#
FEEDRATE OVERRIDE 0%
1
#
JOG FEED OVERRIDE 0%
2
#
Interlock/start lock
3
#
SPEED ARRIVAL ON
4
#
WAIT REVOLUTION
5
#
STOP POSITION CODER
6
The reset / feed hold state is displayed.
DGN 1010 #0
ESP
[Data type]
Bit path
266
Internal state when "1" is displayed
In-position check is being done.
Feedrate override is 0%.
Jog feedrate override is 0%.
Interlock/start lock is on.
The system is waiting for the speed arrival signal
to turn on.
The system is waiting for the spindle one-rotation
signal in threading.
The system is waiting for the rotation of the
position coder in spindle feed per revolution.
B-64805EN/03
Troubleshooting
During emergency stop.
DGN 1010 #1
RRW
[Data type]
Bit path
The reset and rewind signal is “1”.
DGN 1010 #2
ERS
[Data type]
Bit path
The external reset signal is “1”.
DGN 1010 #3
RST
[Data type]
Bit path
The reset key is being pressed.
The items (a) to (e) below are related to manual and automatic operation:
(a) In-position check (positioning check) is being performed (When DGN.0#0 is 1)
It indicates that positioning is not yet completed. Check the following diagnosis data. (The value is "1" in the following
condition.)
DGN.0300 (Position Error) > Parameter No.1826 (In-position width)
DGN 300
Amount of positional deviation for each servo axis
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
0 to ±99999999
Displays the amount of positional deviation for each servo axis in the detection unit.
1826
In-position width for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
2-word axis
Detection unit
0~99999999
The in-position width is set for each axis.
When the deviation of the machine position from the specified position (the absolute value of
the positional deviation) is smaller than the in-position width, the machine is assumed to have
reached the specified position. (The machine is in the in-position state.)
Check the parameters according to the parameter list.
The standard value of parameter No. 1825 is 3000.
267
Troubleshooting
B-64805EN/03
1825
Servo loop gain for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
Word axis
0.01/sec
1 to 32767
Set the loop gain for position control for each axis.
When the machine performs linear and circular interpolation (cutting), the same value must be
set for all axes. When the machine requires positioning only, the values set for the axes may
differ from one another. As the loop gain increases, the response by position control is
improved. A too large loop gain, however, makes the servo system unstable.
The relationship between the positional deviation (the number of pulses counted by the error
counter) and the feedrate is expressed as follows:
Positional deviation = Feedrate / (60 × Loop gain)
Unit:
Amount of positional deviation: mm, inch, or deg
Feedrate: mm/min, inch/min, or deg/min
Loop gain: 1/sec
NOTE
1. This parameter is an initial setting parameter. For details, refer to the appendix
"Automatic setting/Initial setting parameter" in CONNECTION MANUAL (FUNCTION)
or PARAMETER MANUAL.
2. If there is a Cs contouring control axis and a servo axis that performs interpolation, use
parameters No. 3900 to 3944 to ensure that the loop gains of the Cs contouring control
axis and the servo axis are the same during the Cs contouring control mode.
(b) Jog feedrate override is set to 0% (When DGN.0#2 is 1)
Check the signal using the PMC's signal status screen.
Gn010
Gn011
#7
*JV7
*JV15
#6
*JV6
*JV14
#5
*JV5
*JV13
#4
*JV4
*JV12
#3
*JV3
*JV11
#2
*JV2
*JV10
#1
*JV1
*JV9
#0
*JV0
*JV8
When override value is 0%, all bits of the above address is [1111 . . . . 1111] or [0000 . . . . 0000].
*JV15……………………*JV0
Override
1111 1111 1111 1111
1111 1111 1111 1110
:
1101 1000 1110 1111
:
0000 0000 0000 0001
0000 0000 0000 0000
0.00%
0.01%
:
100.00%
:
655.34%
0.00%
(c) Interlock (axis movement prohibited) or start lock signal is input (When DGN.0#3 is 1)
There are a plural interlock signals. Check at first which interlock signal is used by the machine-tool builder in the
parameters. Check the settings of the following parameters:
If the interlock signal *IT is enabled with bit 0 (ITL) of parameter No. 3003 set to 0, Go to 1.
If the interlock signal *ITn is enabled with bit 2 (ITX) of parameter No. 3003 set to 0, Go to 2.
3003 #0
ITL
[Input type]
[Data type]
Parameter input
Bit path
268
B-64805EN/03
Troubleshooting
Interlock signal for all axes is:
0: Enabled.
1: Disabled.
3003 #2
ITX
[Input type]
[Data type]
Parameter input
Bit path
The interlock signal for all axes is:
0: Enabled.
1: Disabled.
The signal corresponding to the bit set is enabled. Check the following signals using the PMC's signal status screen.
1. Interlock signals (*IT, *CSL, and *BSL) are input.
*IT=0, *CSL=0, and *BSL=0 indicate that interlock signal is input from the PMC.
#7
#6
#5
#4
Gn008
#3
*BSL
#2
#1
*CSL
#0
*IT
#3
*IT4
#2
*IT3
#1
*IT2
#0
*IT1
2. Interlock signal for each axis (*ITn) is input
When *ITn is set to 0, interlock signal is being input from the PMC.
#7
*IT8
Gn130
#6
*IT7
#5
*IT6
#4
*IT5
(d) CNC is in a reset state
In this state, "RESET" is also displayed on the state indication of MDI unit's <RESET> key is functioning. So, not only
manual operation but also all automatic operations are disabled. So, referring to IV.1.2. No manual operation nor
automatic operation can be executed(P.265), make an investigation.
(e) The address to which an axis signal is assigned is incorrect
The relationship between each CNC axis and PMC interface address is set in a parameter. Check the setting of the
following parameter:
3021
Address to which an axis signal is assigned
[Input type]
[Data type]
[Data range]
Parameter input
Byte axis
0~7、10~17、20~27、…、90~97
For each axis of the CNC, set a PMC interface address.
The setting values are shown in the table below for parameter (No. 3021) (the second digit)
and parameter (No. 3021) (the first digit).
Table 1.2-1 Value of parameter No. 3021 (the second digit)
Setting
value
0
1
Input signal address
Output signal address
G0000~G0767
F0000~F0767
G1000~G1767
F1000~F1767
:
9
G9000~G9767
F9000~F9767
Table 1.2-2 Value of parameter No. 3021 (the first digit)
Setting
value
0
1
Input signal address
Output signal address
#0
#1
#0
#1
269
Troubleshooting
B-64805EN/03
:
7
#7
#7
Setting example:
Axis
number
1
No.3021
Signal allocation
0
+J1 <G0100.0>、-J1 <G0102.0>、ZP1 <F0090.0>、...
2
1
+J2 <G0100.1>、-J2 <G0102.1>、ZP2 <F0090.1>、...
3
2
+J3 <G0100.2>、-J3 <G0102.2>、ZP3 <F0090.2>、...
4
10
+J4 <G1100.0>、-J4 <G1102.0>、ZP4 <F1090.0>、...
5
11
+J5 <G1100.1>、-J5 <G1102.1>、ZP5 <F1090.1>、...
If eight or less axes are used per path, the following signal allocation results when 0 is set for
all axes:
Axis 1 of path 1 = Setting equivalent to 0
Axis 2 of path 1 = Setting equivalent to 1
:
Axis 1 of path 2 = Setting equivalent to 10
:
NOTE
1. When this parameter is set, the power must be turned off before any operation is
continued.
2. Set this parameter when more than eight axes are used per path.
The valid data range varies, depending on the system software.
■When machine coordinate value does not update on position display
Machine lock signal (MLK) is input.
When the signal is 1, the corresponding machine lock signal is input.
#7
#6
#5
#4
#3
#2
#1
MLK
#0
MLK8
MLK7
MLK6
MLK5
MLK4
MLK3
MLK2
MLK1
Gn044
Gn108
MLK : All axes machine lock
MLKn : Each axis machine lock
1.3.
Jog operation cannot be done
Points
• Check whether position display is operating.
• Check CNC status display.
• Check internal status using CNC diagnostic function.
Causes and Countermeasures
■The position display (relative, absolute, machine coordinates) does not change
■Check the status of mode selection
When the status display shows JOG, it is normal.
When status display does not show JOG, the mode selection signal is not selected correctly. Check the mode
selection signal using the PMC's signal status screen.
270
B-64805EN/03
Troubleshooting
<Mode selection signal>
#7
#6
#5
#4
#3
#2
MD4
Gn043
#1
MD2
#0
MD1
MODE
MD4
MD2
MD1
Manual operation (JOG) mode
1
0
1
■Feed axis direction selection signal is not input
Check the signal using the PMC's signal status screen.
Gn100
#7
+J8
#6
+J7
#5
+J6
#4
+J5
#3
+J4
#2
+J3
#1
+J2
#0
+J1
Gn102
-J8
-J7
-J6
-J5
-J4
-J3
-J2
-J1
When a bit is "1", the corresponding feed axis direction selection signal has been entered.
+Jn
-Jn
+ : Feed in the + direction
- : Feed in the - direction
n (1 to 8) : Feed along the nth axis
Example:
In the normal state, pressing the "+X" button on the operator's panel causes the signal +Jn to be displayed as "1".
This signal becomes effective when the rise of the signal is detected. If, therefore, the direction selection signal has
been entered before jog mode selection, axis movement is not performed; Set the bit "0" and then re-check the
signal.
■Check CNC diagnosis data No. 0000 and 1010
Check the items for which 1 is displayed.
DGN 0
CNC internal state 1
[Data type]
Bit path
Internal state when "1" is displayed
NAME
Internal state when "1" is displayed
271
Troubleshooting
B-64805EN/03
#
0
#
1
#
2
#
3
#
4
#
5
#
6
INPOSITION CHECK
In-position check is being done.
FEEDRATE OVERRIDE 0%
Feedrate override is 0%.
JOG FEED OVERRIDE 0%
Jog feedrate override is 0%.
Interlock/start lock
Interlock/start lock is on.
SPEED ARRIVAL ON
The system is waiting for the speed arrival signal
to turn on.
The system is waiting for the spindle one-rotation
signal in threading.
The system is waiting for the rotation of the
position coder in spindle feed per revolution.
WAIT REVOLUTION
STOP POSITION CODER
The reset / feed hold state is displayed.
DGN 1010 #0
ESP
[Data type]
Bit path
During emergency stop.
DGN 1010 #1
RRW
[Data type]
Bit path
The reset and rewind signal is “1”.
DGN 1010 #2
ERS
[Data type]
Bit path
The external reset signal is “1”.
DGN 1010 #3
RST
[Data type]
Bit path
The reset key is being pressed.
The items (a) to (d) below are related to manual operation:
(a) In-position check (positioning check) is being performed (When DGN.0#0 is 1)
It indicates that positioning is not yet completed. Check the following diagnosis data. (The value is "1" in the following
condition.)
DGN.0300 (Position Error) > Parameter No.1826 (In-position width)
DGN 300
Amount of positional deviation for each servo axis
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
0 to ±99999999
272
B-64805EN/03
Troubleshooting
Displays the amount of positional deviation for each servo axis in the detection unit.
1826
In-position width for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
2-word axis
Detection unit
0~99999999
The in-position width is set for each axis.
When the deviation of the machine position from the specified position (the absolute value of
the positional deviation) is smaller than the in-position width, the machine is assumed to have
reached the specified position. (The machine is in the in-position state.)
Check the parameters according to the parameter list.
The standard value of parameter No. 1825 is 3000.
1825
Servo loop gain for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
Word axis
0.01/sec
1 to 32767
Set the loop gain for position control for each axis.
When the machine performs linear and circular interpolation (cutting), the same value must be
set for all axes. When the machine requires positioning only, the values set for the axes may
differ from one another. As the loop gain increases, the response by position control is
improved. A too large loop gain, however, makes the servo system unstable.
The relationship between the positional deviation (the number of pulses counted by the error
counter) and the feedrate is expressed as follows:
Positional deviation = Feedrate / (60 × Loop gain)
Unit:
Amount of positional deviation: mm, inch, or deg
Feedrate: mm/min, inch/min, or deg/min
Loop gain: 1/sec
NOTE
1. This parameter is an initial setting parameter. For details, refer to the appendix
"Automatic setting/Initial setting parameter" in CONNECTION MANUAL (FUNCTION)
or PARAMETER MANUAL.
2. If there is a Cs contouring control axis and a servo axis that performs interpolation, use
parameters No. 3900 to 3944 to ensure that the loop gains of the Cs contouring control
axis and the servo axis are the same during the Cs contouring control mode.
(b) Jog feedrate override is set to 0% (When DGN.0#2 is 1)
Check the signal using the PMC's signal status screen.
Gn010
Gn011
#7
*JV7
*JV15
#6
*JV6
*JV14
#5
*JV5
*JV13
#4
*JV4
*JV12
#3
*JV3
*JV11
#2
*JV2
*JV10
#1
*JV1
*JV9
#0
*JV0
*JV8
When override value is 0%, all bits of the above address is [1111 . . . . 1111] or [0000 . . . . 0000].
273
Troubleshooting
B-64805EN/03
*JV15……………………*JV0
Override
1111 1111 1111 1111
1111 1111 1111 1110
:
1101 1000 1110 1111
:
0000 0000 0000 0001
0000 0000 0000 0000
0.00%
0.01%
:
100.00%
:
655.34%
0.00%
(c) Interlock (axis movement prohibited) or start lock signal is input (When DGN.0#3 is 1)
There are a plural interlock signals. Check at first which interlock signal is used by the machine-tool builder in the
parameters. Check the settings of the following parameters:
If the interlock signal *IT is enabled with bit 0 (ITL) of parameter No. 3003 set to 0, Go to 1.
If the interlock signal *ITn is enabled with bit 2 (ITX) of parameter No. 3003 set to 0, Go to 2.
3003 #0
ITL
[Input type]
[Data type]
Parameter input
Bit path
Interlock signal for all axes is:
0: Enabled.
1: Disabled.
3003 #2
ITX
[Input type]
[Data type]
Parameter input
Bit path
The interlock signal for all axes is:
0: Enabled.
1: Disabled.
The signal corresponding to the bit set is enabled. Check the following signals using the PMC's signal status screen.
1. Interlock signal (*IT) is input.
When *IT is set to 0, interlock signal is being input from the PMC.
#7
#6
#5
#4
#3
#2
#1
#0
*IT
#3
*IT4
#2
*IT3
#1
*IT2
#0
*IT1
Gn008
2. Interlock signal for each axis (*ITn) is input
When *ITn is set to 0, interlock signal is being input from the PMC.
Gn130
#7
*IT8
#6
*IT7
#5
*IT6
#4
*IT5
(d) CNC is in a reset state
In this status, not only manual operation but also automatic operations are all disabled. So, referring to " IV.1.2. No
manual operation nor automatic operation can be executed(P.265)", make an investigation.
■Manual feedrate (Parameter) is not correct
1423
274
Jog feedrate for each axis
B-64805EN/03
[Input type]
[Data type]
[Data unit]
[Minimum data unit]
[Data range]
Troubleshooting
Parameter input
Real axis
mm/min, inch/min, degree/min (machine unit)
Depends on the increment system of the applied axis.
(See the Standard Parameter Setting Table (C))
(When the increment system is IS-B, 0.0 to +999000.0)
When bit 4 (JRV) of parameter No. 1402 is set to 0 (feed per minute), specify a jog
feedrate (feed per minute) for each axis under a manual feedrate override of 100%.
When bit 4 (JRV) of parameter No. 1402 is set to 1 (feed per revolution), specify a jog
feedrate (feed per revolution) for each axis under a manual feedrate override of 100%.
NOTE
This parameter is clamped to the axis-by-axis manual rapid traverse rate (parameter No.
1424).
■Manual feed per revolution is selected
This function feeds an axis synchronized with spindle rotation and whether this function is used or not is selected by
the following parameter:
1402 #4
JRV
[Input type]
[Data type]
Parameter input
Bit path
Jog feed or incremental feed is:
0: Performed at feed per minute.
1: Performed at feed per revolution.
NOTE
Specify a feedrate in parameter No. 1423.
• If "1" is set, the feedrate of the axis is calculated in synchronization with the rotation of the spindle, so please
proceed by rotating the spindle.
• If the axis does not move even when the spindle is rotated, check the detector of the spindle (position coder) and
the cable between the position coder and the CNC if it is short-circuited or ungrounded.
■The specified axis is the index table indexing axis. <machining center system only>
For the index table indexing axis (B-axis), jog feed, incremental feed, and manual handle feed cannot be performed.
1.4.
HANDLE OPERATION CANNOT BE DONE
Points
If manual handle operation cannot be performed, the probable causes include the following:
• The servo is not activated.
• Manual pulse generators are not connected properly to the I/O module.
• The I/O Link i of the I/O module is not allocated, or is not allocated properly.
• A related input signal is not input due to a parameter setting error.
Also use CNC diagnosis functions to check the internal status.
275
Troubleshooting
B-64805EN/03
Causes and Countermeasures
The servo is not activated
Check that the LED on the servo amplifier indicates "0". If a number other than "0" is indicated, the servo is not
activated. In this state, even JOG operation and automatic operation cannot be operated.
Check the servo-related parameters and the wiring.
■Checking the manual pulse generators
■Cable failures (such as breaks)
Examine the cables for faults such as breaks and short-circuits, referring to Fig. 1.4-1 and Fig. 1.4-2.
Fig. 1.4-1 Example of connection between manual pulse generator and CNC
Part
276
Name
[A]
Main board
[B]
Distributed I/O module or operator's panel I/O module
[C]
Manual pulse generator
B-64805EN/03
Troubleshooting
Fig. 1.4-2 Cable connection between manual pulse generator and CNC
Part
Name
[A]
Main board
[B]
Distributed I/O module or operator's panel I/O module
[C]
Manual pulse generator
■Manual pulse generator failures
Check for any abnormality in the signal output when the manual pulse generator is turned.
There is a terminal for signal measurement on the back of the manual pulse generator. See Fig. 1.4-3.
Fig. 1.4-3 Terminal block on back side of manual pulse generator
277
Troubleshooting
B-64805EN/03
Use an oscilloscope or similar device to measure whether the signal is being output. If the signal is not output,
measure if +5V voltage is output. Measurement can be made at the screw terminal block on the back of the manual
pulse generator.
Fig. 1.4-4 shows HA and HB signal waveforms. Check the on/off ratio of HA and HB, respectively, and the phase
difference between HA and HB for any abnormality.
Fig. 1.4-4 Manual pulse generator signal waveforms
Part
Condition
[A]
Signal when rotating in the positive direction
[B]
Signal when rotating in the negative direction
[C]
Phase difference between HA and HB: 1/4 cycle of HA (or HB)
■Checking the parameters and input signals
For details, see "II.4. CNC state display(P.82)".
■Check CNC status display at lower left corner of the screen
When the status display shows HND, mode selection is correct.
If it is not HND, mode select signal is not input correctly. Check the mode selection signal using the PMC's signal
status screen.
#7
#6
#5
#4
#3
Gn043
MODE
When in manual handle mode
#2
MD4
#1
MD2
#0
MD1
MD4
MD2
MD1
1
0
0
■Manual handle feed axis selection signal is not input
Check the signal using the PMC's signal status screen.
Gn018
Gn019
Gn020
#7
HS2D
#6
HS2C
#5
HS2B
#4
HS2A
Gn379
#7
Gn411
278
#6
#5
#4
#3
HS1D
HS3D
HS4D
#2
HS1C
HS3C
HS4C
#1
HS1B
HS3B
HS4B
#0
HS1A
HS3A
HS4A
HS5D
HS5C
HS5B
HS5A
#3
HS4E
#2
HS3E
#1
HS2E
#0
HS1E
B-64805EN/03
Troubleshooting
Gn412
HS5E
When axis select switch for manual handle feed is selected on the machine operator's panel, if the signals are input
as follows, it is normal.
Selected axis
HSnE
HSnD
HSnC
HSnB
HSnA
no selection
1st axis
2nd axis
3rd axis
4th axis
5th axis
6th axis
7th axis
8th axis
9th axis
10th axis
11th axis
12th axis
13th axis
14th axis
15th axis
16th axis
17th axis
18th axis
19th axis
20th axis
21st axis
22nd axis
23rd axis
24th axis
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
NOTE
In the above table, n is the number of the manual pulse generator (MPG) and up to 5 MPGs can be used. A feed
axis can be selected for each MPG.
■Manual handle feed multiplication is not correct
Check the signal using the PMC's signal status screen. Also confirm the following related parameters based on the
parameter list.
#7
#6
Gn019
#5
MP2
#4
MP1
#3
#2
#1
#0
In handle mode, the travel distance per step can be changed.
7100 #5
MP2
MP1
Step feed
Handle feed
0
0
1
1
0
1
0
1
x1
x 10
x 100
x 1000
x1
x 10
x Mn
x Nn
MPX
279
Troubleshooting
[Input type]
[Data type]
B-64805EN/03
Parameter input
Bit path
In manual handle feed, the manual handle feed travel distance selection signal is:
0:
Manual handle feed travel distance selection signals MP1 and MP2 <Gn019.4,
Gn019.5> for the first manual pulse generator are used as common signals for each
manual pulse generator.
1:
Manual handle feed travel distance selection signals differ depending on the manual
pulse generator as follows:
1st manual pulse generator: MP1, MP2 <Gn019.4, Gn019.5>
2nd manual pulse generator: MP21, MP22 <Gn087.0、Gn087.1>
3rd manual pulse generator: MP31, MP32 <Gn087.3, Gn087.4>
4th manual pulse generator: MP41, MP42 <Gn087.6, Gn087.7>
5th manual pulse generator: MP51, MP52 <Gn380.0, Gn380.1>
7102 #0
HNGx
[Input type]
[Data type]
Parameter input
Bit axis
Compared to the rotation direction of the manual pulse generator, the moving direction of each
axis is:
0: Same in direction.
1: Reverse in direction.
7113
Manual handle feed magnification m
[Input type]
[Data type]
[Data range]
Parameter input
Word path
7114
Manual handle feed magnification n
[Input type]
[Data type]
[Data range]
Parameter input
Word path
1~2000
This parameter sets the magnification n when the manual handle feed travel distance selection
signals MP1, MP2 <Gn019.4, Gn019.5> are set to "1", "1".
7131
Manual handle feed magnification m2/2nd manual pulse generator
7132
Manual handle feed magnification n2/2nd manual pulse generator
7133
Manual handle feed magnification m3/3rd manual pulse generator
7134
Manual handle feed magnification n3/3rd manual pulse generator
7135
Manual handle feed magnification m4/4th manual pulse generator
280
1~2000
This parameter sets the magnification m when the manual handle feed travel distance selection
signals MP1, MP2 <Gn019.4, Gn019.5> are set to "0", "1".
B-64805EN/03
Troubleshooting
7136
Manual handle feed magnification n4/4th manual pulse generator
7137
Manual handle feed magnification m5/5th manual pulse generator
7138
Manual handle feed magnification n5/5th manual pulse generator
[Input type]
[Data type]
[Data range]
Parameter input
Word path
1~2000
mx sets the magnification when the manual handle feed travel distance selection signal MPx1
is "0" and MPx2 is "1".
nx sets the magnification when the manual handle feed travel distance selection signal MPx1 is
"1" and MPx2 is "1".
■The specified axis is the index table indexing axis. <machining center system only>
For the index table indexing axis (B-axis), jog feed, incremental feed, and manual handle feed cannot be performed.
Checking the CNC diagnosis functions
■Check CNC diagnosis data No. 0000 and 1010
Check the items for which 1 is displayed.
DGN 0
CNC internal state 1
[Data type]
Bit path
Internal state when "1" is displayed
NAME
#
INPOSITION CHECK
0
#
FEEDRATE OVERRIDE 0%
1
#
JOG FEED OVERRIDE 0%
2
#
Interlock/start lock
3
#
SPEED ARRIVAL ON
4
#
WAIT REVOLUTION
5
Internal state when "1" is displayed
In-position check is being done.
Feedrate override is 0%.
Jog feedrate override is 0%.
Interlock/start lock is on.
The system is waiting for the speed arrival signal
to turn on.
The system is waiting for the spindle one-rotation
signal in threading.
281
Troubleshooting
B-64805EN/03
#
6
STOP POSITION CODER
The system is waiting for the rotation of the
position coder in spindle feed per revolution.
The reset / feed hold state is displayed.
DGN 1010 #0
ESP
[Data type]
Bit path
During emergency stop.
DGN 1010 #1
RRW
[Data type]
Bit path
The reset and rewind signal is “1”.
DGN 1010 #2
ERS
[Data type]
Bit path
The external reset signal is “1”.
DGN 1010 #3
RST
[Data type]
Bit path
The reset key is being pressed.
The items (a) to (c) below are related to manual operation:
(a) In-position check (positioning check) is being performed (When DGN.0#0 is 1)
It indicates that positioning is not yet completed. Check the following diagnosis data. (The value is "1" in the following
condition.)
DGN.0300 (Position Error) > Parameter No.1826 (In-position width)
DGN 300
Amount of positional deviation for each servo axis
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
0 to ±99999999
Displays the amount of positional deviation for each servo axis in the detection unit.
1826
In-position width for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
2-word axis
Detection unit
0~99999999
282
B-64805EN/03
Troubleshooting
The in-position width is set for each axis.
When the deviation of the machine position from the specified position (the absolute value of
the positional deviation) is smaller than the in-position width, the machine is assumed to have
reached the specified position. (The machine is in the in-position state.)
Check the parameters according to the parameter list.
The standard value of parameter No. 1825 is 3000.
1825
Servo loop gain for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
Word axis
0.01/sec
1 to 32767
Set the loop gain for position control for each axis.
When the machine performs linear and circular interpolation (cutting), the same value must be
set for all axes. When the machine requires positioning only, the values set for the axes may
differ from one another. As the loop gain increases, the response by position control is
improved. A too large loop gain, however, makes the servo system unstable.
The relationship between the positional deviation (the number of pulses counted by the error
counter) and the feedrate is expressed as follows:
Positional deviation = Feedrate / (60 × Loop gain)
Unit:
Amount of positional deviation: mm, inch, or deg
Feedrate: mm/min, inch/min, or deg/min
Loop gain: 1/sec
NOTE
1. This parameter is an initial setting parameter. For details, refer to the appendix
"Automatic setting/Initial setting parameter" in CONNECTION MANUAL (FUNCTION)
or PARAMETER MANUAL.
2. If there is a Cs contouring control axis and a servo axis that performs interpolation, use
parameters No. 3900 to 3944 to ensure that the loop gains of the Cs contouring control
axis and the servo axis are the same during the Cs contouring control mode.
(b) Interlock (axis movement prohibited) or start lock signal is input (When DGN.0#3 is 1)
There are a plural interlock signals. Check at first which interlock signal is used by the machine-tool builder in the
parameters. Check the settings of the following parameters:
If the interlock signal *IT is enabled with bit 0 (ITL) of parameter No. 3003 set to 0, Go to 1.
If the interlock signal *ITn is enabled with bit 2 (ITX) of parameter No. 3003 set to 0, Go to 2.
3003 #0
ITL
[Input type]
[Data type]
Parameter input
Bit path
Interlock signal for all axes is:
0: Enabled.
1: Disabled.
3003 #2
ITX
[Input type]
[Data type]
Parameter input
Bit path
283
Troubleshooting
B-64805EN/03
The interlock signal for all axes is:
0: Enabled.
1: Disabled.
The signal corresponding to the bit set is enabled. Check the following signals using the PMC's signal status screen.
1. Check the interlock signal (*IT) is input
*IT=0 indicates interlock signal is input.
#7
#6
#5
#4
#3
#2
#1
#0
*IT
#5
*IT6
#4
*IT5
#3
*IT4
#2
*IT3
#1
*IT2
#0
*IT1
Gn008
2. Check each axis interlock signal (*ITn) is input
*ITn=0 indicates interlock signal is input.
#7
*IT8
Gn130
#6
*IT7
(c) CNC is in a reset state
In this status, not only manual operation but also automatic operations are all disabled. So, referring to " IV.1.2. No
manual operation nor automatic operation can be executed(P.265)", make an investigation.
1.5.
Automatic operation cannot be done
Points
• Check manual operation is possible
• Check the status of cycle start LED on machine operator's manual
• Check status of CNC
Causes and Countermeasures
When manual operation is either impossible, perform countermeasure, based on the Section, " IV.1.3. Jog operation
cannot be done(P.270)".
Confirm that a correct mode is selected according to the mode select status of CNC status display. Also, by
confirming the automatic operation status it is possible to identify cycle operation, feed hold and cycle stop state.
When cycle operation is not started (Cycle start LED does not light)
"****" is displayed at CNC status display at the bottom of the screen.
■Mode select signal is not correct
When the mode select signal of the operator's panel is input correctly, following status display is done.
MDI : Manual data input mode (MDI)
MEM: Memory operation mode
RMT: Remote operation mode
When the display is not correct, check the following mode signals in the PMC's signal status screen.
#7
#6
Gn043
284
#5
DNCI
DNCI
MD4
MD2
MD1
0
0
0
0
0
0
1
#4
#3
#2
MD4
Mode select
Manual data input (MDI) mode
Automatic operation (MEM) mode
#1
MD2
#0
MD1
B-64805EN/03
Troubleshooting
DNCI
MD4
MD2
MD1
1
0
0
1
Mode select
Remote operation mode
■Cycle start signal is not input
Automatic operation actuates when the automatic operation start (cycle start) signal changes from "1" to "0".
Therefore, it is necessary to check on the PMC's signal status screen that the signal is being input correctly.
This signal turns "1" when cycle start button is pressed and turns "0" when it is released.
#7
#6
#5
#4
#3
Gn007
#2
ST
#1
#0
ST: Cycle (start) signal
■Feed hold signal is input
Under normal state, the feed hold signal is "1" when the feed hold button is not pressed. Check the signal state using
the PMC's signal status screen.
#7
#6
Gn008
#5
*SP
#4
#3
#2
#1
#0
*SP: Feed hold signal
■When an automatic operation is in progress (Cycle start LED is lit)
CNC's status display shows "STRT" on the screen.
■Check the content displayed for the CNC diagnostic data (No.0)
Check the items for which 1 is displayed at the right side.
DGN
DGN 0
CNC internal state 1
[Data type]
Bit path
Internal state when "1" is displayed
NAME
#
INPOSITION CHECK
0
#
FEEDRATE OVERRIDE 0%
1
#
JOG FEED OVERRIDE 0%
2
#
Interlock/start lock
3
#
SPEED ARRIVAL ON
4
#
WAIT REVOLUTION
5
#
STOP POSITION CODER
6
Internal state when "1" is displayed
In-position check is being done.
Feedrate override is 0%.
Jog feedrate override is 0%.
Interlock/start lock is on.
The system is waiting for the speed arrival signal
to turn on.
The system is waiting for the spindle one-rotation
signal in threading.
The system is waiting for the rotation of the
position coder in spindle feed per revolution.
The items (a) to (e) below are related to automatic operation:
285
Troubleshooting
B-64805EN/03
(a) In-position check (confirming positioning) is being done. (When DGN.0#0 is 1)
Positioning (G00) to a specified position of a specified axis is not completed.
Whether positioning is completed or not is checked as the servo position error amount. Check the following diagnosis
data:
DGN.0300 (Position Error) > Parameter No.1826 (In-position width)
DGN 300
Amount of positional deviation for each servo axis
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
0 to ±99999999
Displays the amount of positional deviation for each servo axis in the detection unit.
1826
In-position width for each axis
[Input type]
[Data type]
[Data unit]
[Data range]
Parameter input
2-word axis
Detection unit
0~99999999
The in-position width is set for each axis.
When the deviation of the machine position from the specified position (the absolute value of
the positional deviation) is smaller than the in-position width, the machine is assumed to have
reached the specified position. (The machine is in the in-position state.)
Position error amount almost becomes "0" when positioning of an axis completes. When the amount becomes within
the in-position width, it is assumed that positioning completes and the next block is executed.
(b) Feedrate override is at 0%. (When DGN.0#1 is 1)
Actual feedrate is overridden by the override signals to a programmed feedrate. Check the signal state using the
PMC's signal status screen.
Override signal
Gn012
#7
*FV7
#6
*FV6
#5
*FV5
#4
*FV4
#3
*FV3
#2
*FV2
#1
*FV1
#0
*FV0
*FV0 to *FV7: Feedrate override signal
<2nd feedrate override optional function>
In addition to the above override signals, more detailed overrides can be applied using the following signals. Refer to
the manual provided by the machine tool builder to find out whether this feature is equipped.
Gn013
#7
*AFV7
#6
*AFV6
#5
*AFV5
#4
*AFV4
*AFV0 to *AFV7: 2nd feedrate override signals
286
#3
*AFV3
#2
*AFV2
#1
*AFV1
#0
*AFV0
B-64805EN/03
Troubleshooting
Table 1.5-1 Override signal state
Signals (*FV7……*FV0)
Signals (*AFV7…*AFV0)
*FV7……*FV0
*AFV7…*AFV0
11111111
11111110
:
10011011
:
00000001
00000000
0%
1%
:
100%
:
254%
0%
11111111
11111110
:
10011011
:
00000001
00000000
0%
1%
:
100%
:
254%
0%
(c) Manual feedrate override is 0% (dry run) (When DGN.0#2 is 1)
Normally, manual feedrate override function is used for jog feed. But when DRN (dry run) signal turns on during an
automatic operation, override values set with these signals become valid to the following speed set by a parameter.
DRN=1 indicates dry run signal is input.
Gn046
#7
DRN
#6
#5
#4
#3
#2
#1
#0
1410
Dry run rate
[Input type]
[Data type]
[Data unit]
[Minimum data unit]
[Data range]
Parameter input
Real path
mm/min, inch/min, degree/min (machine unit)
Depends on the increment system of the reference axis.
(See the Standard Parameter Setting Table (C))
(When the increment system is IS-B, 0.0 to +999000.0)
Set the dry run rate at the 100% position on the jog feedrate specification dial. The data unit
depends on the increment system of the reference axis. When this parameter is set to 0, the
alarm PS5009 "PARAMETER ZERO(DRY RUN)" occurs.
The rate at 100% is set by the following override signal.
Gn010
Gn011
#7
*JV7
*JV15
#6
*JV6
*JV14
#5
*JV5
*JV13
#4
*JV4
*JV12
#3
*JV3
*JV11
#2
*JV2
*JV10
#1
*JV1
*JV9
#0
*JV0
*JV8
When override value is 0%, all bits of the above address is [1111 . . . . 1111] or [0000 . . . . 0000].
*JV15……………………*JV0
Override
1111 1111 1111 1111
1111 1111 1111 1110
:
1101 1000 1110 1111
:
0000 0000 0000 0001
0000 0000 0000 0000
0.00%
0.01%
:
100.00%
:
655.34%
0.00%
(d) Interlock signal (axis movement prohibited) is input. (When DGN.0#3 is 1)
There are a plural number of interlock functions. Parameters are set by machine tool builders for which interlock
(signal) is used. Therefore, confirm the following parameters at first:
If the interlock signal *IT is enabled with bit 0 (ITL) of parameter No. 3003 set to 0, Go to 1.
287
Troubleshooting
B-64805EN/03
If the interlock signal *ITn is enabled with bit 2 (ITX) of parameter No. 3003 set to 0, Go to 2.
3003 #0
ITL
[Input type]
[Data type]
Parameter input
Bit path
Interlock signal for all axes is:
0: Enabled.
1: Disabled.
3003 #2
ITX
[Input type]
[Data type]
Parameter input
Bit path
The interlock signal for all axes is:
0: Enabled.
1: Disabled.
The signal corresponding to the bit set is enabled. Check the following signals using the PMC's signal status screen.
1. Interlock signals (*IT, *CSL, and *BSL) are input.
*IT=0, *CSL=0, and *BSL=0 indicate that interlock signal is input from the PMC.
#7
#6
#5
#4
Gn008
#3
*BSL
#2
#1
*CSL
#0
*IT
#2
*IT3
#1
*IT2
#0
*IT1
2. Interlock signal for each axis (*ITn) is input
*ITn=0 indicates the corresponding axis's interlock signal is input from the PMC.
Gn130
#7
*IT8
#6
*IT7
#5
*IT6
#4
*IT5
#3
*IT4
3. Indicates that an axis movement command has been issued to a removed axis.
NOTE
This function is enabled only when bit 7 (RMBx) of CNC side parameter No. 1005 is set to 1.
For whether this function is running or not, check the following signal using the PMC's signal status
screen. Check the axis where "1" is displayed.
•
The control axis detach signal (DTCHx) is input from the PMC.
DTCHx=1 indicates the corresponding axis is detached.
Gn124
•
#7
DTCH8
#6
DTCH7
#5
DTCH6
#4
DTCH5
#3
DTCH4
#1
DTCH2
#0
DTCH1
The following parameters on the CNC side enable the axis removal function for the corresponding axis.
0012 #7
RMVx
[Input type]
[Data type]
Setting input
Bit axis
The axis that corresponds to this parameter is:
0 Set as a controlled axis.
:
1 Not set as a controlled axis.
:
288
#2
DTCH3
B-64805EN/03
Troubleshooting
The effect is equivalent to the controlled axis detach signals DTCH1, DTCH2, ...,
<Gn124>.
NOTE
1. The parameter RMVx is enabled when bit 7 (RMBx) of parameter No. 1005
is set to 1.
2. Change the parameter RMVx while the axis is stopped. When switching
while the axis is moving, controlled axis detach is performed after the
movement of the axis is completed.
(e) CNC is waiting for spindle speed arrival signal to be input
(When DGN.0#4 is 1)
Actual spindle speed does not arrive at a speed specified in a program.
Check the signal state using the PMC's signal status screen.
When this signal is 0, spindle speed does not arrive at the specified speed.
This function is enabled when the bit 0 (SAR) of parameter No. 3708 is set to 1.
#7
#6
#5
Gn029
#4
SAR
#3
#2
#1
#0
■When positioning (G00) does not operate only during rapid traverse, the following parameters
and signals from the PMC should be checked.
(a) Setting value of rapid traverse rate
1420
Rapid traverse rate for each axis
[Input type]
[Data type]
[Data unit]
[Minimum data unit]
[Data range]
Parameter input
Real axis
mm/min, inch/min, degree/min (machine unit)
Depends on the increment system of the applied axis.
(See the Standard Parameter Setting Table (C))
(When the increment system is IS-B, 0.0 to +999000.0)
Set the rapid traverse rate for each axis when the rapid traverse override is 100%.
(b) Rapid traverse override signals
#7
#6
#5
Xn008
#4
*ESP
Gn008
*ESP
#3
#2
#1
#0
#7
#6
#5
#4
#3
#2
#1
ROV2
#0
ROV1
HROV
*HROV6
*HROV5
*HROV4
*HROV3
*HROV2
*HROV1
*HROV0
Gn014
Gn096
HROV=0
HROV=1
ROV1
ROV2
Override
*HROV6……*HROV0
Override
0
1
0
1
0
1
1
1
100%
50%
25%
F0
1111111
1111110
:
0011011
0%
1%
:
100%
289
Troubleshooting
B-64805EN/03
1421
F0 rate of rapid traverse override for each axis
[Input type]
[Data type]
[Data unit]
[Minimum data unit]
[Data range]
Parameter input
Real axis
mm/min, inch/min, degree/min (machine unit)
Depends on the increment system of the applied axis.
(See the Standard Parameter Setting Table (C))
(When the increment system is IS-B, 0.0 to +999000.0)
Set the F0 rate of the rapid traverse override for each axis.
■Only feed (other than G00) does not function
(a) Maximum feedrate set by parameter is incorrect.
Feedrate (other than G00) is clamped at this upper feedrate.
1430
Maximum cutting feedrate for each axis
[Input type]
[Data type]
[Data unit]
[Minimum data unit]
[Data range]
Parameter input
Real axis
mm/min, inch/min, degree/min (machine unit)
Depends on the increment system of the applied axis.
(See the Standard Parameter Setting Table (C))
(When the increment system is IS-B, 0.0 to +999000.0)
Specify the maximum cutting feedrate for each axis.
(b) Feedrate is specified by feed per revolution (mm/rev)
1. (1) Position coder is not rotating.
Check the connection between spindle and position coder.
The following failure is considered:
Timing belt is broken
Key is removed
Coupling is loose
Connector of signal cable is loosened
2. Failure of position coder
(c) Thread cutting does not operate
1. Position coder does not rotate.
Check the connection between spindle and position coder.
The following failure is considered:
Timing belt is broken
Key is removed
Coupling is loose
Connector of signal cable is loosened
2. Failure of position coder
Position coder is connected to the spindle amplifier when serial interface spindle is used or connected to the CNC
when analog interface spindle is used.
For details of connection, refer to the following.
290
B-64805EN/03
Troubleshooting
Whether A/B phase signals from the position coder are read correctly, can be judged also by the spindle speed
display on the screen (current position display screen). (However, it is not displayed when bit 2 (DPS) of
parameter No. 3105 is set to 0).
•
In the case of αi series spindle amplifier
(d) A cutting feed block containing a feedrate command (F command) with a feedrate of 0 is specified.
If the bit 7 (FCO) of parameter No. 1404 is set to 1, alarm PS0011, "FEED ZERO (COMMAND)" is not issued even if
a feedrate command (F command) with a feedrate of 0 is issued.
1.6.
Cycle start led signal has turned off
Points
• After cycle operation is started, then stopped, check according to this procedure:
• Check the cycle start LED on the machine operator's panel.
• Check the CNC's diagnosis function.
Causes and Countermeasures
Check the states of the related signals on the signal status screen of PMC.
■Emergency stop signal is input
*ESP=0 indicates that emergency stop signal is input.
Xn008
#7
#6
#5
#4
*ESP
Gn008
*ESP
#3
#2
#1
#0
#3
#2
#1
#0
■External reset signal is input
When ERS is 1, external reset signal is input.
Gn008
#7
ERS
#6
#5
#4
This signal is usually used for a confirmation signal of M02 by the PMC when an M02 is specified in a program as the
end of a program. Therefore, when M02 is executed, this signal is input.
■<RESET> key is pressed
An automatic operation is put into a reset status when the <RESET> key is pressed.
291
Troubleshooting
B-64805EN/03
■Reset & rewind signal is input
RRW=1 indicates that reset & rewind signal is input.
#7
#6
RRW
Gn008
#5
#4
#3
#2
#1
#0
This signal is usually used for a confirmation signal of M30 by the PMC when an M30 is specified in a program as the
end of a program. Therefore, when M30 is executed, this signal is input.
■A servo alarm is generated
When any servo alarm has generated, cycle operation is put into the reset state and the operation stops.
■Cycle operation is in a feed hold state
The reasons for entering a temporary pause state include the following conditions.
• Modes are switched from an automatic operation mode to a manual operation mode.
• When automatic operation halt (Feed hold) signal is input
Mode selection signal
#7
#6
#5
#4
#3
Gn043
Automatic
operation/Manual
operation
Automatic operation
Manual operation
#2
MD4
#1
MD2
#0
MD1
Operation Mode
MD4
MD2
MD1
Memory edit (EDIT)
Automatic operation (AUTO)
Manual data input (MDI)
Jog feed (JOG)
Handle/step
TEACH IN HANDLE
TEACH IN JOG
0
0
0
1
1
1
1
1
0
0
0
0
1
1
1
1
0
1
0
1
0
Automatic operation halt signal
*SP=0 indicates that automatic operation stop signal is input.
#7
#6
Gn008
#5
*SP
#4
#3
#2
#1
#0
#3
#2
#1
SBK
#0
■It become single block stop during automatic operation
When the SBK signal is set to 1, the single block signal is input.
#7
#6
Gn046
1.7.
#5
#4
Nothing is displayed on the LCD, or the display disappears and is
not restored
Causes and Countermeasures
If nothing is displayed on the LCD when power is turned on, or if the LCD was displaying but then disappears and is
not restored, the following are possible causes:
292
B-64805EN/03
Troubleshooting
■For the LCD-mounted type control unit
See "I.1.3.2. LED Mounting Positions and LED Indications on LCD Unit (P.40)" to check the LED lighting status on the back
of the LCD unit.
• If any LED on the LCD unit is lit → Go to Action A
• If no LEDs on the LCD unit are lit → Go to Action B
■Action A
•
The control unit may not securely mate with the LCD unit. Ensure that these units are firmly mated. See
V.1.2.1. Replacing the LCD-mounted type control unit(P.669).
•
The FANUC iPC graphic board may have a poor connection or the board may be malfunctioning. Ensure
that the FANUC iPC graphic board securely mate with the control unit. If the issue still continues, replace
the FANUC iPC graphic board. See V.1.3.2. Replacement of non-main board(P.723).
•
The LCD unit may be faulty. Replace the LCD unit. See V.1.2.3. Replacing LCD units(P.680).
■Action B
•
The control unit may not securely mate with the LCD unit. Ensure that these units are firmly mated. See
V.1.2.1. Replacing the LCD-mounted type control unit(P.669).
•
Power may not be supplied to the control unit. Check the power connections, such as the power cable.
If the problem has not been resolved at this point, see " Fig. 1.2.4-2(P.19)" and check the power board LED lighting
status.
•
If any LED on the power supply board is lit → Go to Action C
•
If no LEDs on the power supply board are lit → Go to Action D
■Action C
•
The power supply board may be out of order. Replace the board or the fuse that corresponds to the faulty
location listed in "Fig. 1.2.4-2(P.19)". See V.1.3. Replacement of various printed circuit board(P.718) or V.1.6.1.
Replace fuses on power board(P.736) for details.
■Action D
•
The fan may have failed and cut off the power supply for protection.
If the fan has stopped, replace the fan. See V.1.4. Replacement of fan unit and fan(P.725).
Even if the fan has not stopped, it is possible that the fan has stopped once and been restored for some
reason. Turn the power off and on, check the system alarm history, and if there is any history related to low
fan speed, replace the fan. For instructions on displaying the system alarm history, see II.8.3.1. Displaying the
System Alarm History screen(P.122).
•
The LCD unit may be faulty. Replace the LCD unit.
■For the stand-alone type control unit
See "I.1.3.2. LED Mounting Positions and LED Indications on LCD Unit (P.40)" to check the LED lighting status on the back
of the LCD unit.
• If any LED on the LCD unit is lit → Go to Action E
• If no LEDs on the LCD unit are lit → Go to Action F
■Action E
•
The LCD control unit may not securely mate with the LCD unit. Ensure that these units are firmly mated.
•
The LCD control unit may be faulty. Refer to the LCD control unit manual and take appropriate action.
•
The LCD unit may be faulty. Replace the LCD unit. See V.1.2.3. Replacing LCD units(P.680).
■Action F
•
The LCD control unit may not securely mate with the LCD unit. Ensure that these units are firmly mated.
293
Troubleshooting
1.8.
B-64805EN/03
•
Power may not be supplied to the LCD control unit. Check the power connections, such as the power cable.
•
The LCD control unit may be faulty. Refer to the LCD control unit manual and take appropriate action.
•
The LCD unit may be faulty. Replace the LCD unit. See V.1.2.3. Replacing LCD units(P.680).
The displayed content is distorted or does not fit within the screen
Causes and Countermeasures
Changing the text size or zoom settings in the OS or browser settings may cause the displayed content to be
distorted or appear to extend outside the screen.
If the settings are changed, please check that the screen displays correctly.
If it does not display correctly, restore the settings.
1.9.
Input from and output to i/o devices cannot be performed,
input/output cannot be performed properly
Causes and Countermeasures
If the I/O Link i is not established, if the input signals from an I/O unit are not input normally to the CNC, or if the
output signals from the CNC are not output to an I/O device, the probable causes include the following:
• The I/O unit is not powered or not at proper voltage.
• I/O Link i connection cable is not connected properly or is incorrectly wired.
• The grounding is not proper.
• The input/output signal terminals are not connected correctly.
• I/O Link i allocation data is not set correctly.
■Checking alarms
Press the <Message> key to display the message screen and check for PMC or IOL alarms.
NOTE
For details on PMC alarms, see "IV.2.1.13. PMC Alarms (PMC Alarm)(P.452)".
For details on IOL alarms, see "IV.2.1.14. I/O Link i Alarms (IOL Alarm)(P.457)".
■Checking connected units and allocation data on the I/O Link i screen
Check the I/O units connected to the CNC and I/O Link i allocation data on the I/O Link i screen.
The I/O Link i screen is displayed by launching the PMC screen from the Maintenance category of the menu screen
and selecting [I/O Link i] > [ChannelX (X=1-3)] in the tree of the PMC screen.
294
B-64805EN/03
Troubleshooting
Fig. 1.9-1 I/O Link i connection check screen
Fig. 1.9-2 I/O Link i allocation data screen
295
Troubleshooting
B-64805EN/03
NOTE
For details on the I/O Link i screen, see "Series 500i-A PMC PROGRAMMING MANUAL" (B-64803EN-3).
■Checking I/O unit power supply
Check that the connected I/O units are connected properly to the power supplies and that the voltages are as
prescribed.
Check that the power-on sequence is correct.
Time at which an I/O unit is to be turned on:
Before the CNC is turned on or within 500 ms after the CNC is turned on
When turning off the CNC, the I/O unit must also be turned off (for details, see the chapter "TURNING ON AND OFF
THE POWER TO THE CONTROL UNIT" in "Series 500i-A CONNECTION MANUAL (HARDWARE)" (B-64803EN)).
■Checking connection cables
I/O Link i cables are used to connect JD1A (JD51A) and JD1B. JD1A (JD51A) represents an upper unit while JD1B
represents a lower unit.
Check that the cables are connected correctly.
■Check grounding
Check that the ground wires are connected and are not loose.
■Checking input/output signals
Check that the input/output signal terminals are connected to I/O units correctly.
For I/O units with common setting pins, check that 0V or +24V is connected to the common setting pins and that
+24V is connected to the DO common pins for output signals.
296
B-64805EN/03
1.10.
Troubleshooting
ALARM SR0085 TO 87 (RELATED TO RS-232C INTERFACE)
Causes and Countermeasures
■Parameter setting on RS-232C interface are incorrect
Check the following setting data and parameters.
Setting
PUNCH CODE=0 OR 1 (0: EIA,1:ISO)
Select ISO or EIA according to the type of I/O device.
If punch code does not match, alarm SR0086, "DR OFF" will generate.
297
Troubleshooting
B-64805EN/03
Parameters
Setting value of parameter 020
Function
Feed
Data input code
Stop bit
Type of I/O device
Baud rate
0
1
2
0101#7
0101#3
0101#0
102
103
0111#7
0111#3
0111#0
112
113
Main board
0121#7
0121#3
0121#0
122
123
Connector
JD56A
NOTE
Numbers in the table indicate parameters and bit numbers.
Example: 101#7 indicates bit 7 of parameter 101.
0101 #7
0111 #7
NFD
0121 #7
For data output, the feed before and after data is:
0: Output (FANUC PPR)
1: Not output (standard)
0101 #3
0111 #3
ASI
0121 #3
For data input, the code used is:
0: EIA or ISO code (auto-detected)
1: ASCII code
0101 #0
0111 #0
SB2
0121 #0
The number of stop bits is:
6.9444444444444404E-4
4.30555555555555E-2
0102
0112
0122
298
Type of I/O device
JD36A
B-64805EN/03
Setting value
0
4
Troubleshooting
TYPE OF I/O DEVICE
RS-232C (when using control codes DC1 to DC4)
RS-232C (when not using control codes DC1 to DC4)
0103
0113
Baud rate
0123
Setting value
Baud rate
7
8
9
10
11
12
600
1200
2400
4800
9600
19200
■External I/O device or Host computer is in trouble
(a) Check whether the setting on communication of external I/O device or host computer is the same as that of the
CNC side (baud rate, stop bits, etc.). If they are not the same, change the setting.
(b) When spare I/O device presents, check whether it is possible to realize communication using the spare I/O device.
■Main board or serial communication board is faulty
(a) When parameter No.0020 is "0", "1", or "2" (JD70A and JD70B of Main board), replace the module as the main
board may be faulty.
■Cable between CNC and RS-232C-compatible device is faulty
Check the cable between CNC and RS-232C-compatible device for disconnection or wrong connection.
The cable connection between the control unit and the RS-232C compatible device is described in Fig. 1.10-1, and the
cable wiring are shown in the Fig. 1.10-2.
299
Troubleshooting
B-64805EN/03
Fig. 1.10-1 Cable connection with the RS-232C compatible devices
Part
Name
[A]
Control unit
[B]
RS-232C interface connector (connector number JD70A)
[C]
RS-232C interface connector (connector number JD70B)
[D]
RS-232C compatible devices
NOTE
1CH (connector number JD70A) and 2CH (connector number JD70B) are both RS-232C compliant interfaces.
However, their detailed specifications are different as the circuit inside the printed circuit board are different.
Do not connect anything with the pin of (N. C).
Do not wire with the pins 18 and 20 (+5 V).
300
B-64805EN/03
Troubleshooting
Fig. 1.10-2 RS-232C compatible device cable wiring
Part
[A]
Name
Shield
1.11.
ALARM PS0090 (REFERENCE POSITION RETURN IS ABNORMAL)
Contents
Reference position return was executed when the following condition is not satisfied: The CNC received one rotation
signal at least one time when the axis is moving to the reference position at a speed higher than a speed equivalent
to 128 pulses of position error amount (DGN300).
301
Troubleshooting
Action
302
B-64805EN/03
B-64805EN/03
Troubleshooting
After the Pulsecoder or motor is exchanged, reference position or machine's standard point may be different from
former one. Please set it correctly.
NOTE
A speed more than 128 pulses is required because if speed is lower that this, one-rotation signal does not function
stably, causing improper position detection.
If bit 0 of parameter No. 2000 is set to 1, a speed corresponding to a positional deviation of 1280 pulses or more is
required.
Parameter No. 1836 can be set to 128 or less, as the minimum positional deviation with which reference position
return is possible. (If the parameter is set to "0", 128 is assumed as the minimum positional deviation. If bit 0 of
parameter No. 2000 is set to 1, a value equal to ten times the set value is used for checking).
1.12.
ALARM DS0300 (REQUEST FOR REFERENCE POSITION RETURN)
Contents
Absolute position data in the serial Pulsecoder was lost.
(This alarm will be generated when serial Pulsecoder is exchanged or position feedback signal cable of the serial
Pulsecoder is disconnected. )
Action
Machine position must be memorized using the following method:
303
Troubleshooting
B-64805EN/03
■When reference position return function is present
1. Execute manual reference position return only for an axis for which this alarm was generated.
When manual reference position return cannot be executed because of an another alarm, set bit 5 (APCx) of
parameter No. 1815 to 0 and release the alarm and perform manual operation.
2. Press the <RESET> key at the end of reference position return to release the alarm.
■When reference position return function is not present
Execute reference position setting without DOG to memorize the reference position.
■When serial Pulsecoder is changed
Since the stop position of the reference position is different from the former one, change the grid shift value
(parameter No. 1850) to correct the stop position.
Related parameters
1815 #4
APZx
When an absolute position detector is used as a position detector, the position correspondence between the machine
position and the absolute position detector is:
0: Not completed
1: Completed
When an absolute position detector is used, after primary adjustment is performed or after the absolute position
detector is replaced, this parameter must be set to 0, power must be turned off and on, then manual reference position
return must be performed. This completes the positional correspondence between the machine position and the
position on the absolute position detector, and sets this parameter to 1 automatically.
1815 #5
APCx
The position detector is:
0: Other than absolute position detector
1: Absolute position detector (absolute pulsecoder).
1.13.
ALARM SV0401 (V READY OFF)
Causes and Countermeasures
This alarm is issued if the servo ready signal VRDY of a servo amplifier does not turn on or if the signal turns off
during operation.
There are cases in which this alarm is issued because another servo alarm is issued. If this occurs, first take the
action to the first alarm.
Check the power magnetic circuit around the amplifier. The servo amplifier or the main board on the CNC side also
may be defective.
304
B-64805EN/03
Troubleshooting
■VRDY
The exchange of this information is performed via the FSSB (optical cable).
■Example of connection around the amplifier (schematic diagram)
Check items
• Is the Common Power Supply on?
• Has an emergency stop been canceled?
• Is MCC on? If there is an external MCC sequence in addition to the MCC contact of the Common Power Supply,
also check that sequence.
• Is the power for driving MCC supplied?
• Is the breaker on?
• Has some alarm been issued in the Common Power Supply or spindle amplifier? Check the diagnosis data No.
358, (V ready-off information). For details, see "IV.3.1. Diagnosis list(P.534)".
■Replacing the servo amplifier
If there is no problem with the strong electric circuit around the amplifier, replace the servo amplifier.
■Replacing the main board on the CNC side
If the above action does not solve the problem, replace the main board on the CNC side.
305
Troubleshooting
1.14.
B-64805EN/03
ALARM SV0404 (V READY ON)
Causes and Countermeasures
This alarm is issued if the servo ready signal (VRDY) of a servo amplifier remains on.
The servo amplifier or the main board on the CNC side may be defective.
■VRDY
The exchange of this information is performed via the FSSB (optical cable).
This alarm is issued if VRDY remains on when the CNC turns MCON off or if VRDY turns on before the CNC turns
MCON on.
■Replacing the servo amplifier
The servo amplifier may be defective. Replace the servo amplifier.
■Replacing the main board on the CNC side
If replacing the servo amplifier does not solve the problem, replace the main board on the CNC side.
1.15.
ALARM SV0462 (SEND CNC DATA FAILED), ALARM SV0463 (SEND
SLAVE DATA FAILED)
Causes and Countermeasures
Alarm SV0462 is issued if a slave (servo amplifier) cannot receive correct data due to an FSSB communication error.
Alarm SV0463 is issued if the CNC cannot receive correct data due to an FSSB communication error.
If these alarms are issued, the alarm message indicates the number of the defective axis (axis name).
■Servo amplifier or optical cable
Any of the optical cables between the CNC control unit and the amplifier corresponding to the axis number indicated
in the alarm message may be defective.
Or, any of the first amplifier to the amplifier corresponding to that axis number may be defective.
■Main board on the CNC side
The main board on the CNC side may be faulty.
1.16.
ALARM SV0417 (DIGITAL SERVO SYSTEM IS ABNORMAL)
Digital servo parameters are abnormal.
Digital servo parameters are set incorrectly. After checking the diagnostic data (No. 203#4, 280, 352), please change
the settings for the relevant servo parameters. For details, see " IV.3.1. Diagnosis list(P.534)".
306
B-64805EN/03
Troubleshooting
Cause
• Check bit 4 of diagnosis data No. 203 to see where the alarm was detected.
If bit 4 of diagnosis data No. 203 = 0: CNC detection parameter is incorrect. Check diagnosis data No. 280 for
details.
If bit 4 of diagnosis data No. 203 = 1: Servo detection parameter is incorrect. Check diagnosis data No. 352 for
details.
• If a CNC detection parameter is invalid, check diagnosis data No. 280 and the settings of the following
parameters.
Parameter No. 2020 : Motor format number
Parameter No. 2022 : Motor rotation direction
Parameter No. 2023 : Number of pulses of velocity feedbacks
Parameter No. 2024 : Number of pulses of position feedback
Parameter No. 1023 : Servo axis number
Parameter No. 2084 : Flexible feed gear ratio
Parameter No. 2085 : Flexible feed gear ratio
Parameter No. 2211#6 : 2-winding motor is used.
Parameter No. 2211#7 : 4-winding motor is used.
• In the case of incorrect servo detection parameters, please check the cause using diagnosis data No. 352 and
correct the relevant servo parameters accordingly. Refer to "AC SERVO MOTOR αi-B/αi series, AC SERVO
MOTOR βi-B/βi series, LINEAR MOTOR LiS-B/LiS series, DD MOTOR DiS-B/DiS series PARAMETER MANUAL"
(B-65270EN) for explanations about the value of diagnosis data No. 352 and how to correct the invalid parameter
setting.
1.17.
ALARMS OH10000 TO OH10003 (OVERHEAT)
Causes and Countermeasures
This alarm is issued if the ambient temperature of the CNC control unit is abnormally high. As an installation
condition, the ambient temperature of the CNC must not exceed the following temperatures.
• LCD-mounted type control unit: 58°C
• Stand-alone type control unit: 55°C
■Ambient temperature
A temperature monitoring circuit is installed on the main board and CPU board, and issues this alarm if the ambient
temperature is abnormally high.
• OH10000, OH10001, OH10002: Temperature anomaly is detected on the main board
• OH10003: Temperature anomaly is detected on the CPU board
Take appropriate action to the cabinet that houses the CNC control unit so that the temperature falls within the proper
temperature range (0 to 58°C (for LCD-mounted type) or 0 to 55°C (for stand-alone type)).
If it is obvious that the ambient temperature is not abnormal, the main board or CPU board may be defective.
1.18.
ALARM SV5134 (FSSB: OPEN READY TIME OUT) ALARM SV5137
(FSSB: CONFIGURATION ERROR) ALARM SV5197 (FSSB: OPEN
TIME OUT)
Causes and Countermeasures
These alarms are issued due to a failure in the optical cable, the main board on the CNC side, or a slave such as a
servo amplifier connected to the FSSB. They are also issued if the setting of a parameter related to the FSSB is
incorrect. After checking the diagnostic data (No. 3510, 3511, 3513), please change the settings for the relevant
parameters. For details, see "IV.3.1. Diagnosis list(P.534)".
307
Troubleshooting
Number
B-64805EN/03
Message
5134
FSSB:OPEN READY TIME OUT
5137
FSSB:CONFIGURATION ERROR
5197
FSSB:OPEN TIME OUT
Contents
In the initialization, the FSSB could not be in an open ready sate.
The main board on the CNC side may be faulty.
An FSSB configuration error occurred. /
The connecting amplifier type is incompatible with the FSSB
setting value.
The initialization of the FSSB was completed, but it could not be
opened. /
Or, the connection between the CNC and the amplifier in is
incorrect.
■Check parameter settings.
Check that the FSSB-related parameters are set correctly.
■Power supplies of the servo amplifiers
Check the power supplies of the servo amplifiers connected to the FSSB.
■Replacing the main board on the CNC side, optical cables, and servo amplifiers
Replace the main board on the CNC.
Replace the optical cables and servo amplifiers connected to the FSSB, one at a time, to identify the defective item.
1.19.
Alarm SV1067 (Diagnosis No. 3511=481) (FSSB: Configuration
Error (Software))
Causes and Countermeasures
The connecting amplifier type is incompatible with the FSSB setting value.
■FSSB setting screen
If this alarm is issued, display the amplifier setting screen from the FSSB setting screen. Only the servo amplifiers
recognized on the FSSB are displayed.
■Optical cable or servo amplifier
The optical cable that connects together the last recognized amplifier and the next one may be defective.
Or, either of the amplifiers connected together with that optical cable may be defective. Check the power supplies of
the amplifiers.
■Power failure of servo amplifier
This alarm may be issued if a power fault occurs in a servo amplifier. A power fault occurs if the amplifier control
power supply voltage drops, if the +5 V conductor of the Pulsecoder cable is ground, or for other reasons.
■Main board on the CNC side
The main board on the CNC side may be faulty.
1.20.
Servo alarms
The servo alarms are listed in Appendix, "IV.2.1.5. Servo Alarms (SV Alarm)(P.393)". For explanations about the alarms
related to servo amps and servo motors, refer to "SERVO MOTOR αi-D series, SPINDLE MOTOR αi-D series,
SERVO AMPLIFIER αi-D series MAINTENANCE MANUAL" (B-65555EN).
If the hardware on the CNC is suspected to be defective as a result of examination, replace the main board.
1.21.
Spindle alarms
For an explanation of the following spindle alarms, refer to "SERVO MOTOR αi-D series, SPINDLE MOTOR αi-D
series, SERVO AMPLIFIER αi-D series MAINTENANCE MANUAL" (B-65555EN).
308
B-64805EN/03
Troubleshooting
Number
SP9001 to later: Spindle_n
Contents
n-th spindle alarm (Spindle alarm display 01 or larger)
1.22.
System alarms
1.22.1.
Overview
A system alarm state is entered when a state that prevents the continuation of normal system operation is detected.
When a system alarm state is entered, actions including the following are performed.
• Servo and spindle amplifier excitation is turned OFF
• I/O Link i communication is disconnected
• The system alarm screen is displayed
System alarms can be caused by a variety of factors, ranging from issues occurring in the CNC system software to
those occurring in hardware.
Typical causes are as follows:
• Conflict in processing/data detected by the internal state monitoring software
• Access to outside of the valid data/instruction ranges
• Division by zero
• Stack overflow
• Parity error (DRAM, SRAM, cache)
• FSSB cable disconnection
• Servo software (such as watchdog)
• PMC software (such as an I/O link communication error)
For causes and solutions of each system alarm, see IV.2.4. System alarm(P.482).
1.22.2.
System Alarm Screen
When a system alarm state is entered with CNCBOOT residing in the task tray, the display switches to the system
alarm screen as shown below.
In the system alarm screen, you can view and edit information on currently occurring system alarms and perform
various operations.
309
Troubleshooting
B-64805EN/03
Fig. 1.22.2-1 System Alarm Screen
Number
Description
1
Series and edition of CNC system software
2
System alarm number
3
Message
4
Parts to replace
5
Location of error (may not displayed depending on the system alarm number)
6
Time of occurrence
7
Binary data of system alarm information
8
9
Displays the path of the display unit storage used for output/input.
When selected, the File Location screen is displayed.
Displays the About screen, which shows the edition number of CNCBOOT.
10
Updates the currently displayed information.
11
12
Used to schedule to start CNCBOOT for the next startup.
If a CNCBOOT schedule has been already made, the [Cancel Schedule] button is displayed for canceling
the schedule.
Exports information on the system alarm as a binary file.
13
Closes the system alarm screen.
1.23.
LEDs ON UNITS SUPPORTING I/O LINK I
See "FANUC I/O unit MAINTENANCE MANUAL" (B-64795EN) for details on the LEDs on I/O Link i-compatible units.
310
B-64805EN/03
Alarm list
2.
Alarm list
2.1.
Alarm list (CNC and PMC)
2.1.1.
Program Operation Alarms (PS Alarm)
These alarm may also occur for the shared alarm numbers in " (2) Background editing alarms (BG Alarm)(P.382)", and "(3)
Communication alarms (SR Alarm)(P.387)".
Also refer to the above mentioned sections depending on the alarm type.
Number
Message
Contents
PS0003
TOO MANY DIGIT
Data entered with more digits than permitted in the NC instruction word. The number of
permissible digits varies according to the function and the address.
Number
Message
Contents
PS0004
INVALID BREAK POINT OF WORDS
NC word(s) address + numerical value not in word format.
This alarm is also generated when a custom macro does not contain a reserved word, or does
not conform to the syntax.
Number
Message
Contents
PS0005
NO DATA AFTER ADDRESS
NC word(s) address + numerical value not in word format.
This alarm is also generated when a custom macro does not contain a reserved word, or does
not conform to the syntax.
Number
Message
Contents
PS0006
ILLEGAL USE OF MINUS SIGN
A minus sign (-) was specified at an NC instruction word or system variable where no minus
signal may be specified.
Number
Message
Contents
PS0007
ILLEGAL USE OF DECIMAL POINT
A decimal point (.) was specified at an address where a decimal point is not allowed.
Or two decimal points or more were specified.
Number
Message
Contents
PS0009
IMPROPER NC-ADDRESS
An illegal address was specified,
or parameter 1020 is not set.
Number
Message
Contents
PS0010
IMPROPER G-CODE
An unusable G code is specified.
The commanded optional function is invalid.
Number
Message
Contents
PS0011
FEED ZERO(COMMAND)
The cutting feedrate instructed by an F code has been set to "0".
311
Alarm list
B-64805EN/03
This alarm is also generated if the F code instructed for the S code is set extremely small
in a rigid tapping instruction as the tool cannot cut at the programmed lead.
During groove cutting by continuous circle motion, correct Q or F value is not specified or
the acceleration clamp value for continuous circle motion in parameter No. 3490 is invalid.
Number
Message
Contents
PS0015
TOO MANY SIMULTANEOUS AXES
More movement commands have been given than the number of contouring control axes.
Divide the movement axis of the program command into two blocks.
Number
Message
Contents
PS0020
OVER TOLERANCE OF RADIUS
An arc was specified for which the difference in the radius at the start and end points exceeds
the value set in parameter No. 3410. Check arc center codes I, J and K in the program.
The tool path when parameter No. 3410 is set to a large value is spiral.
Number
Message
Contents
PS0021
ILLEGAL PLANE SELECT
The plane selection instructions G17 to G19 are in error.
Reprogram so that same 3 basic parallel axes are not specified simultaneously.
This alarm is also generated when an axis that should not be specified for plane machining is
specified, for example, for circular interpolation or involute interpolation.
To allow more than three axes to be commanded, a corresponding helical interpolation is
required for each of the axis.
Number
Message
Contents
PS0022
R OR I,J,K COMMAND NOT FOUND
The command for circular interpolation lacks arc radius R or coordinate I, J, or K of the
distance between the start point to the center of the arc.
Number
Message
Contents
PS0025
CIRCLE CUT IN RAPID(F0)
F0 (one-digit F code feed or rapid traverse in inverse feed) was specified during circular
interpolation (G02, G03) or involute interpolation (G02.2, G03.2).
Number
Message
Contents
PS0027
NO AXES COMMANDED IN G43/G44
No axis is specified in G43 and G44 blocks for the tool length compensation type C. Offset is
not canceled but another axis is offset for the tool length compensation type C. Multiple axes
were specified for the same block when the tool length compensation type is C.
Number
Message
Contents
PS0029
ILLEGAL OFFSET VALUE
The offset number is incorrect.
Number
Message
Contents
PS0030
ILLEGAL OFFSET NUMBER
An illegal offset No. was specified.
This alarm is also generated when the tool shape offset No. exceeds the maximum number of
tool offset sets in the case of tool offset memory B.
In cutting point command, this alarm is also generated when the corner R offset No. ( [H code
+ 2] or [H code + 2 * (parameter No. 11419)] ) exceeds the maximum number of tool offset sets
in the case of tool offset memory A and B.
Number
PS0031
312
B-64805EN/03
Alarm list
Message
Contents
ILLEGAL P COMMAND IN G10
The G10 L No. contains no relevant data input or corresponding option.
Data setting address P or R is not specified.
An address not relating to the data setting is specified. Which address to specify varies
according to the L No.
The sign, decimal point or range of the specified address are in error.
Number
Message
Contents
PS0032
ILLEGAL OFFSET VALUE IN G10
In writing an offset amount by programmable data G10 or system variables, the offset amount
was excessive.
Number
Message
Contents
PS0033
NO INTERSECTION AT CUTTER COMPENSATION
The intersection cannot be obtained by the intersection calculation in tool radius - tool nose
radius compensation. Please correct the program.
Number
Message
Contents
PS0034
ONLY G00/G01 ALLOWED IN STUP/EXT BLK
In tool radius - tool nose radius compensation, a startup or cancellation is performed in the
following mode. Please correct the program.
G02/G03: Circular interpolation/Helical interpolation
G35/G36: Circular threading
G02.2/G03.2: Involute interpolation
Number
Message
Contents
PS0035
CAN NOT COMMANDED G31
G31 cannot be specified. This alarm is generated when a G code (such as for tool radius tool nose radius compensation) of group 07 is not canceled.
A torque limit skip was not specified in a torque limit skip command (G31P98 or P99).
Specify the torque limit skip in the PMC window or the like. Or, specify the torque limit
override by address Q.
G31 cannot be specified. The function that cannot be used when bit 7 (SOR) of parameter
No. 6216 is set to 1 is enabled.
Number
Message
Contents
PS0037
CAN NOT CHANGE PLANE IN G41/G42
The compensation plane G17/G18/G19 was changed during tool radius - tool nose radius
compensation. Modify the program.
Number
Message
Contents
PS0041
INTERFERENCE IN G41/G42
Tool radius - tool nose radius compensation may cause excessive depth of cut. Please correct
the program or offset value.
Number
Message
Contents
PS0042
G45/G48 NOT ALLOWED IN CRC
Tool offset (G45 to G48) is commanded in tool radius compensation or 3-dimensional tool
compensation. Please correct the program.
Number
Message
PS0044
G27-G30 NOT ALLOWED IN FIXED CYC
313
Alarm list
B-64805EN/03
Contents
The command which relates to the reference position return is commanded in canned cycle
mode. Please correct the program.
Number
Message
Contents
PS0045
ADDRESS Q NOT FOUND (G73/G83)
In a peck drilling cycle (G73) or peck drilling cycle (G83), the amount of each-time cutting is not
specified by address Q, or Q0 is specified. Please correct the program.
Number
Message
Contents
PS0046
ILLEGAL REFERENCE RETURN COMMAND
The second, third, and fourth reference position return command is illegal (error in address P
specification).
Number
Message
Contents
PS0047
ILLEGAL AXIS SELECT
Two or more parallel axes (in parallel with a basic axis) have been specified upon start-up of 3dimensional coordinate conversion.
Number
Message
Contents
PS0048
BASIC AXIS NOT FOUND
Start-up of 3-dimensional coordinate conversion has been attempted, but the three basic axes
used when Xp, Yp, or Zp is omitted are not set in parameter No. 1022.
Number
Message
Contents
PS0049
ILLEGAL COMMAND(G68,G69)
When 3-dimensional coordinate conversion (G68 or G69) was specified, the tool length
compensation was not canceled. Or, programs of 3-dimensional coordinate conversion (G68,
G69) and tool length compensation (G43, G44 or G49) were not nested. Or, the 3-dimensional
coordinate conversion was specified during the tool length compensation and another tool
length compensation was specified.
Number
Message
Contents
PS0050
CHF/CNR NOT ALLOWED IN THRD BLK
Chamfering/corner R is commanded in the thread cutting block. Please correct the program.
Number
Message
Contents
PS0051
MISSING MOVE AFTER CNR/CHF
Improper movement or the move distance was specified in the block next to the
chamfering/corner R block.
Modify the program.
Number
Message
Contents
PS0052
CODE IS NOT G01 AFTER CHF/CNR
The block next to the chamfering/corner R block is not G01 (or vertical line).
Please correct the program.
Number
Message
Contents
PS0053
TOO MANY ADDRESS COMMANDS
In the chamfering/corner R commands, two or more of I, J, K and R are specified.
Number
Message
Contents
PS0054
NO TAPER ALLOWED AFTER CHF/CNR
A block in which chamfering/corner R was specified is executing a taper command. Please
correct the program.
314
B-64805EN/03
Alarm list
Number
Message
Contents
PS0055
MISSING MOVE VALUE IN CHF/CNR
In the block where chamfering/corner R was specified, the move distance is less than the
chamfering/corner R amount. Please correct the program.
Number
Message
Contents
PS0056
NO END POINT & ANGLE IN CHF/CNR
In direct drawing dimension programming, both an end point and an angle were specified in the
block next to the block in which only an angle was specified (Aa). Please correct the program.
Number
Message
Contents
PS0057
NO SOLUTION OF BLOCK END
Block end point is not calculated correctly in direct drawing dimension programming. Please
correct the program.
Number
Message
Contents
PS0058
END POINT NOT FOUND
Block end point is not found in direct drawing dimension programming. Please correct the
program.
Number
Message
Contents
PS0060
SEQUENCE NUMBER NOT FOUND
[External Data I/O]
In program number and sequence number search, the specified number cannot be found.
There was an I/O request issued for a pot No. or offset (tool data), but either no tool numbers
have been input since power ON Or there is no data for the entered tool No.
[External workpiece number search]
The program corresponding to the specified workpiece No. could not be found.
[Program restart]
In the program restart sequence number specification, the specified sequence number cannot
be found.
Re-check the restarting block.
Number
Message
Contents
PS0061
P OR Q COMMAND IS NOT IN THE MULTIPLE REPETIVE CYCLES BLOCK
Address P or Q is not specified in multiple repetitive cycle (G70, G71, G72, or G73) command.
Number
Message
Contents
PS0062
THE CUTTING AMOUNT IS ILLEGAL IN THE ROUGH CUTTING CYCLE
In a rough-cutting cycle of a multiple repetitive cycle (G71 or G72), a zero or a negative value
was specified as the depth of cut.
Number
Message
Contents
PS0063
THE BLOCK OF A SPECIFIED SEQUENCE NUMBER IS NOT FOUND
The block of the sequence number specified by addresses P or Q in a multiple repetitive cycle
(G70, G71, G72, or G73) command cannot be found.
Number
Message
Contents
PS0064
THE FINISHING SHAPE IS NOT A MONOTONOUS CHANGE(FIRST AXES)
In a shape program for a rough-cutting cycle of a multiple repetitive cycle (G71 or G72), the
command for the first plane axis was not a monotonous increase or decrease.
Number
PS0065
315
Alarm list
B-64805EN/03
Message
Contents
G00/G01 IS NOT IN THE FIRST BLOCK OF SHAPE PROGRAM
In the first block of the shape program specified by P of the multiple repetitive cycle (G70, G71,
G72, or G73), G00 or G01 was not specified.
Number
Message
Contents
PS0066
UNAVAILABLE COMMAND IS IN THE MULTIPLE REPETIVE CYCLES BLOCK
An unavailable command was found in a multiple repetitive cycle (G70, G71, G72, or G73)
command block.
Number
Message
Contents
PS0067
THE MULTIPLE REPETIVE CYCLES IS NOT IN THE PART PROGRAM STORAGE
A multiple repetitive cycle (G70, G71, G72, or G73) command is not registered in a tape
memory area.
Number
Message
Contents
PS0069
LAST BLOCK OF SHAPE PROGRAM IS AN ILLEGAL COMMAND
In a shape program in the multiple repetitive cycle (G70, G71, G72, or G73), a command for
the chamfering/corner R in the last block is terminated in the middle.
Number
Message
Contents
PS0070
NO PROGRAM SPACE IN MEMORY
The memory area is insufficient. Delete any unnecessary programs, then retry.
Number
Message
Contents
PS0072
TOO MANY PROGRAMS
The number of registered programs has exceeded the limit. Delete unnecessary programs and
execute program registration again.
Number
Message
Contents
PS0073
PROGRAM NUMBER ALREADY IN USE
The commanded program number has already been used. Change the program number or
delete unnecessary programs and execute program registration again.
Number
Message
Contents
PS0074
ILLEGAL PROGRAM NUMBER
The program number is other than 1 to 9999. Modify the program number.
Number
Message
Contents
PS0075
PROTECT
An attempt was made to register a program whose number was protected.
In program matching, the password for the encoded program was not correct.
A program in background editing was selected as the main program.
A program in background editing was called as a subprogram.
Number
Message
Contents
PS0076
PROGRAM NOT FOUND
The specified program is not found in the subprogram call, macro call, or figure copy.
The M, G, T or S codes are called by a P instruction other than that in an M98, G65, G66,
G66.1 or interruption type custom macro, and a program is called by a second auxiliary
function code.
This alarm is also generated when a program is not found by these calls.
Number
PS0077
316
B-64805EN/03
Alarm list
Message
Contents
TOO MANY SUB,MACRO NESTING
The total number of subprogram and custom macro calls exceeded the permissible range.
Another subprogram call was executed during an external memory subprogram call.
Number
Message
Contents
PS0078
SEQUENCE NUMBER NOT FOUND
The specified sequence number cannot be found in sequence number search.
The sequence number of the jump destination specified in GOTO-- and M99P-- cannot be not
be found.
Number
Message
Contents
PS0079
PROGRAM NOT MATCH
The program in memory does not match the program stored on tape.
Multiple programs cannot be matched continuously when bit 6 (NPE) of parameter No. 3201 is
set to "1". Set bit 6 (NPE) of parameter No. 3201 to "0" before executing a match.
Number
Message
Contents
PS0080
G37 MEASURING POSITION REACHED SIGNAL IS NOT PROPERLY INPUT
For machining center systems
When the automatic tool length measurement function (G37) is performed, a measuring
position reached signal goes 1 in front of the area determined by the ε value specified in
parameter No.6254. Alternatively, the signal does not go 1.
For lathe systems
When the automatic tool offset function (G36, G37) is used, a measuring position reached
signals (XAE1, XAE2) does not go 1 within the range determined by the ε value specified
in parameters Nos. 6254 and 6255.
Number
Message
Contents
PS0081
G37 TOOL OFFSET NO. UNASSIGNED
For machining center systems
The automatic tool length measurement (G37) was specified by the automatic tool length
measurement function without specifying an H code.
Please correct the program.
For lathe systems
The automatic tool offset (G36, G37) was specified by the automatic tool offset function
without specifying a T code.
Please correct the program.
Number
Message
Contents
PS0082
G37 SPECIFIED WITH TOOL OFFSET NO.
For machining center systems
The automatic tool length measurement function (G37) is specified together with an H
code in the same block.
Please correct the program.
For lathe systems
The automatic tool offset function (G36, G37) is specified together with an T code in the
same block.
Please correct the program.
Number
Message
Contents
PS0083
G37 IMPROPER AXIS COMMAND
For machining center systems
An error has been found in axis specification of the automatic tool length measurement
function (G37). Alternatively, a move command is specified as an incremental command.
Please correct the program.
For lathe systems
An error has been found in axis specification of the automatic tool offset (G36, G37).
Alternatively, a command is specified as an incremental command.
Please correct the program.
317
Alarm list
B-64805EN/03
Number
Message
Contents
PS0090
REFERENCE RETURN INCOMPLETE
The reference position return cannot be performed normally because the reference
position return start point is too close to the reference position or the speed is too slow.
Separate the start point far enough from the reference position, or specify a sufficiently
fast speed for reference position return.
An attempt was made to set the zero position for the absolute position detection by
reference position return when it was impossible to set the zero point.
Rotate the motor manually at least one turn, and set the zero position of the absolute
position detection after turning the CNC and servo amplifier off and then on again.
Number
Message
Contents
PS0091
MANUAL REFERENCE POSITION RETURN IS NOT PERFORMED IN FEED HOLD
Manual reference position return cannot be performed when automatic operation is stopped.
Perform the manual return to the reference position when automatic operation is stopped or
reset.
Number
Message
Contents
PS0092
ZERO RETURN CHECK (G27) ERROR
The axis specified in G27 has not returned to zero.
Reprogram so that the axis returns to zero.
Number
Message
Contents
PS0109
FORMAT ERROR IN G08
A value other than 0 or 1 was specified after P in the G08 code, or no value was specified.
Number
Message
Contents
PS0110
TOO MANY DIGIT
An integer went out of range during arithmetic calculations.
Number
Message
Contents
PS0111
OVERFLOW :FLOATING
A decimal point (floating point number format data) went out of range during arithmetic
calculations.
Number
Message
Contents
PS0112
ZERO DIVIDE
An attempt was made to divide by zero in a custom macro.
Number
Message
Contents
PS0114
ILLEGAL EXPRESSION FORMAT
The format used in an expression in a custom macro statement is in error.
The parameter tape format is in error.
Number
Message
Contents
PS0115
VARIABLE NO. OUT OF RANGE
A number that cannot be used for a local variable, common variable, or system variable in a
custom macro is specified.
In the skip function for EGB axis (G31.8) or skip function for flexible synchronization control, a
non-existent custom macro variable number is specified. Or, the number of custom macro
variables used to store skip positions is not sufficient.
Alternatively, the header data in high-speed cycle cutting is improper. This alarm is issued in
the following cases.
The header corresponding to the specified call machining cycle number is absent.
318
B-64805EN/03
Alarm list
The value of cycle connection information falls outside the allowable range (0 to 999).
The number of data items in the header falls outside the allowable range (1 to 65535).
The storage start data variable number of executable data falls outside the allowable
ranges (#20000 to #85535, #200000 to #986431, #2000000 to #3999999).
The storage end data variable number of executable data falls outside the allowable
ranges (#85535, #986431, #3999999).
The storage start data variable number of executable data is the same as the variable
number used by the header.
Number
Message
Contents
PS0116
WRITE PROTECTED VARIABLE
An attempt was made in a custom macro to use on the left side of an expression a variable that
can only be used on the right side of an expression.
Number
Message
Contents
PS0118
TOO MANY BRACKET NESTING
Too many brackets "[ ]" were nested in a custom macro.
The nesting level including function brackets is 5.
Number
Message
Contents
PS0119
ARGUMENT VALUE OUT OF RANGE
The value of an argument in a custom macro function is out of range.
Number
Message
Contents
PS0122
TOO MANY MACRO NESTING
Too many macro calls were nested in a custom macro.
Number
Message
Contents
PS0123
ILLEGAL MODE FOR GOTO/WHILE/DO
A GOTO statement or WHILE-DO statement was found in the main program in the MDI or DNC
mode.
Number
Message
Contents
PS0124
MISSING END STATEMENT
The END instruction corresponding to the DO instruction was missing in a custom macro.
Number
Message
Contents
PS0125
MACRO STATEMENT FORMAT ERROR
The format used in a macro statement in a custom macro is in error.
Number
Message
Contents
PS0126
ILLEGAL LOOP NUMBER
DO and END Nos. in a custom macro are in error, or exceed the permissible range (valid
range: 1 to 3).
Number
Message
Contents
PS0127
DUPLICATE NC,MACRO STATEMENT
An NC statement and macro statement were specified in the same block.
Number
Message
Contents
PS0128
ILLEGAL MACRO SEQUENCE NUMBER
The specified sequence number cannot be found in sequence number search.
The sequence number of the jump destination specified in GOTO-- and M99P-- cannot be
found.
319
Alarm list
B-64805EN/03
Number
Message
Contents
PS0129
USE 'G' AS ARGUMENT
Illegal address is commanded in a custom macro call. Please confirm whether the address is
valid in the macro call. When using the axis name expansion, please confirm the setting of the
parameter (No.11647).
Number
Message
Contents
PS0130
NC AND PMC AXIS ARE CONFLICTED
The NC command and the PMC axis control command were conflicted. Correct the
program or PMC sequence program.
A PMC axis control auxiliary function was specified for the group used by the Motion
Script auxiliary function.
Number
Message
Contents
PS0136
SPOS AXIS - OTHER AXIS SAME TIME
The spindle positioning axis and another axis are specified in the same block.
Number
Message
Contents
PS0137
M-CODE & MOVE CMD IN SAME BLK.
The spindle positioning axis and another axis are specified in the same block.
Number
Message
Contents
PS0139
CANNOT CHANGE PMC CONTROL AXIS
The PMC axis was selected for the axis for which the PMC axis is being controlled.
Number
Message
Contents
PS0140
PROGRAM NUMBER ALREADY IN USE
In the background, an attempt was made to select or delete the program being selected in the
foreground. Operate properly for the background editing.
Number
Message
Contents
PS0142
ILLEGAL SCALE RATE
The scaling rate is 0 times or 10000 times or more. Correct the scaling rate setting value (G51
P_ …, G51 I_ J_ K_ …, or parameters (No.5411, 5421))
Number
Message
Contents
PS0143
COMMAND DATA OVERFLOW
An overflow occurred in the storage length of the CNC internal data.
This alarm is also generated when the result of internal calculation of scaling, coordinate
system rotation and cylindrical interpolation overflows the data storage.
It also is generated during input of the manual intervention amount.
Number
Message
Contents
PS0144
ILLEGAL PLANE SELECTED
The coordinate system rotation plane and arc or tool radius - tool nose radius compensation
plane must be the same. Please correct the program.
Number
Message
Contents
PS0145
ILLEGAL USE OF G12.1/G13.1
The axis No. of plane selection parameter No. 5460 (linear axis) and No. 5461(axis of rotation)
in the polar coordinate interpolation mode is out of range (1 to number of controlled axes).
Number
PS0146
320
B-64805EN/03
Alarm list
Message
Contents
ILLEGAL USE OF G-CODE
The modal G code group contains an illegal G code in the polar coordinate interpolation mode
or when a mode was canceled.
Use the following G codes.
G40, G50.1, G69.1
An illegal G code was specified while in the polar coordinate interpolation mode.
The following G codes are not allowed:
G27, G28, G30, G30.1, G31 to G31.4, G37 to G37.3, G52, G92, G53, G17 to G19, G81 to
G89, G68
In the 01 group, G codes other than G01, G02, G03, G02.2 and G03.2 cannot be specified.
Number
Message
Contents
PS0149
FORMAT ERROR IN G10L3
In registration (G10 L3 to G11) of tool life management data, an address other than Q1, Q2,
P1, and P2 or an unusable address was specified.
Number
Message
Contents
PS0150
ILLEGAL LIFE GROUP NUMBER
The tool group number exceeded the maximum allowable value. The tool group number (P
after specification of G10 L3;) or the group number given by the tool life management T code in
a machining program.
Number
Message
Contents
PS0151
GROUP NOT FOUND AT LIFE DATA
The tool group specified in a machining program is not set in tool life management data.
Number
Message
Contents
PS0152
OVER MAXIMUM TOOL NUMBER
The number of tools registered in one group exceeded the maximum allowable registration tool
number.
Number
Message
Contents
PS0153
T-CODE NOT FOUND
In registration of tool life data, a block in which the T code needs to be specified does not
include the T code. Or the M06 is specified independently using tool change method D. Please
correct the program.
Number
Message
Contents
PS0154
NOT USING TOOL IN LIFE GROUP
When using tool management function
H99 or D99 was specified when no tool management data number is assigned to the
spindle position. Please correct the program.
When using tool life management
The H99 command, D99 command, or the H/D code set by parameters Nos. 13265 and
13266 was specified when no tool belonging to a group is used.
Number
Message
Contents
PS0155
ILLEGAL T-CODE COMMAND
In the machining program, the T code that is present in the block containing M06 does not
correspond to the group currently being used. Please correct the program.
Number
Message
Contents
PS0156
P/L COMMAND NOT FOUND
The P and L commands are not specified in the beginning of a program for setting a tool group.
Please correct the program.
321
Alarm list
B-64805EN/03
Number
Message
Contents
PS0157
TOO MANY TOOL GROUPS
In registration of tool life management data, the group setting command block counts of P
(group number) and L (tool life) exceeded the maximum group count.
Number
Message
Contents
PS0158
TOOL LIFE VALUE OUT OF RANGE
The specified life time value is too large. Change the setting.
Number
Message
Contents
PS0159
ILLEGAL TOOL LIFE DATA
Tool life management data is corrupted for some reason. Register the tool data in the tool
group or the tool data in the group again by “G10 L3 ;” or MDI input.
Number
Message
Contents
PS0160
MISMATCH WAITING M-CODE
A waiting M-code is in error.
When different M codes are specified for path 1 and path 2 as waiting M codes without a
P command
When the waiting M codes are not identical even though the P commands are identical
When the waiting M codes are identical and the P commands are not identical (This
occurs when a P command is specified with binary value)
When the number lists in the P commands contain a different number even though the
waiting M codes are identical (this occurs when a P command is specified by combining
path numbers)
When a waiting M code without a P command (2-path waiting) and a waiting M code with
a P command (3-or-more-path waiting) were specified at the same time
When a waiting M code without a P command was specified for 3 or more paths
When a high-speed type waiting M code is not a single command
Number
Message
Contents
PS0161
ILLEGAL P OF WAITING M-CODE
P in a waiting M-code is incorrect.
When address P is negative
When a P value inappropriate for the system configuration was specified
When a waiting M code without a P command (2-path waiting) was specified in the system
having 3 or more paths.
When P7 and L0 were specified at the same time
Number
Message
Contents
PS0163
ILLEGAL COMMAND IN G68/G69
G68 and G69 are not independently commanded in balance cut.
An illegal value is commanded in a balance cut combination (address P).
Number
Message
Contents
PS0169
ILLEGAL TOOL GEOMETRY DATA
Incorrect tool figure data in interference check. Set correct data, or select correct tool figure
data.
Number
Message
Contents
PS0175
ILLEGAL G07.1 AXIS
An axis which cannot perform cylindrical interpolation was specified.
More than one axis was specified in a G07.1 block.
An attempt was made to cancel cylindrical interpolation for an axis that was not in the
cylindrical interpolation mode.
322
B-64805EN/03
Alarm list
For the cylindrical interpolation axis, to specify the arc with a rotary axis (by setting bit 0 (ROT)
of parameter No. 1006 to 1 and then setting parameter No. 1260), set parameter No. 1022 to
either 5, 6, or 7 (parallel axis specification) rather than 0 (rotary axis specification).
Number
Message
Contents
PS0176
ILLEGAL USE OF G-CODE
A G code was specified that cannot be specified in the cylindrical interpolation mode.
This alarm also is generated when an 01 group G code was in the G00 mode or code G00 was
instructed.
Cancel the cylindrical interpolation mode before instructing code G00.
Number
Message
Contents
PS0179
PARAM.(NO.7510)SETTING ERROR
The number of controlled axes set by the parameter No. 7510 exceeds the maximum number.
Modify the parameter setting value.
The distribution of high-speed cycle cutting or high-speed binary program operation stopped.
Number
Message
Contents
PS0190
ILLEGAL AXIS SELECT
An illegal value was specified in P in a G96 block or parameter No. 3770.
When spindle selection by address P of multi spindle or by spindle name expansion is enabled,
selection of axis as the calculation reference in constant surface speed control "G96 P_ ;"
cannot be commanded.
Number
Message
Contents
PS0194
SPINDLE COMMAND IN SYNCHRO-MODE
A Cs contouring control mode, spindle positioning command, or rigid tapping mode has been
specified in the spindle synchronous control mode or spindle command synchronous control
mode.
Number
Message
Contents
PS0197
C-AXIS COMMANDED IN SPINDLE MODE
The program specified a movement along the Cs-axis when the Cs contouring control
switching signal was off.
Number
Message
Contents
PS0200
ILLEGAL S CODE COMMAND
1. In the rigid tap, an S value was out of range or was not specified. The parameters Nos.
5241 to 5243 setting is an S value which can be specified for the rigid tap. Correct the
parameters or modify the program.
2. If rigid tap was specified during constant surface speed control: Specify rigid tap after
cancelling constant surface speed control.
Number
Message
Contents
PS0201
FEEDRATE NOT FOUND IN RIGID TAP
The cutting feedrate instructed by an F code has been set to "0".
This alarm is also generated if the F code instructed for the S code is set extremely small in a
rigid tapping instruction as the tool cannot cut at the programmed lead.
Number
Message
Contents
PS0202
POSITION LSI OVERFLOW
In the rigid tapping, spindle distribution value is too large (system error). Lower the spindle
speed.
Number
PS0203
323
Alarm list
B-64805EN/03
Message
Contents
PROGRAM MISS AT RIGID TAPPING
In the rigid tap, position for a rigid M code (M29) or an S command is incorrect. Please
correct the program.
If bit 3 (MSE) of parameter No. 5206 is set to 1, multiple spindles via spindle command
synchronous control and rigid tapping via 1 servo axis cannot be used with FSSB highspeed rigid tapping
The bit 1 of parameter No. 2429, bit 2 of parameter No. 2429, bit 1 of parameter No. 4549,
and bit 2 of parameter No. 4549 settings in the FSSB high-speed rigid tapping are
erroneous.
In the FSSB high-speed rigid tapping, bit 1 (FHRSV) of parameter No. 2429 is incorrectly
set.
For 3-dimensional rigid tapping, set parameter FHRSV to 1 for all 3 axes.
For flexible path axis assignment or composite control, set parameter FHRSV of
the switched servo axis to 1.
In axis synchronous control, set parameter FHRSV to 1 for both the master and
slave axes.
If performing smart rigid tapping while synchronizing multiple spindles by spindle
command synchronous control
Smart rigid tapping cannot be used with a 1 drilling axis and multiple spindle
configuration.
The drilling axis cannot be positioned across multiple paths.
Smart rigid tapping cannot be specified in the parking or machine lock for each
axis state.
3-dimensional rigid tapping cannot be specified if there are no three feed axes for
each spindle.
3-dimensional rigid tap cannot be specified if bit 4 (M3S) of parameter No. 5206 is
set to 0.
Number
Message
Contents
PS0204
ILLEGAL AXIS OPERATION
In the rigid tap, an axis movement is specified between the rigid M code (M29) block and G84
(or G74) block. Please correct the program.
Number
Message
Contents
PS0205
RIGID MODE DI SIGNAL OFF
1. Although a rigid M code (M29) is specified in rigid tapping, the rigid mode DI signal
(RGTAP<G061.0>) is not ON during execution of the G84 (or G74) block. Check the PMC
sequence program to find the reason why the DI signal is not turned ON.
2. When rigid tapping is performed, a spindle that selects a command for that path is not
found. Or, the spindles in multiple paths select the commands in the same path. Check
the spindle command select signal.
3. The spindle specified for rigid tapping is already being executed in a different path.
4. In the device with multi spindle control, the spindle for rigid tapping is not selected when
performing rigid tapping.
5. The rigid tapping command was specified for the rotary tool axis by a servo motor in
another path.
Number
Message
Contents
PS0206
CAN NOT CHANGE PLANE (RIGID TAP)
Plane changeover was specified in rigid tap mode. Please correct the program.
Number
Message
Contents
PS0207
RIGID DATA MISMATCH
RIGID DATA MISMATCH
The specified distance was too short or too long in rigid tapping.
Number
Message
PS0210
CAN NOT COMMAND M198/M99
324
B-64805EN/03
Contents
Alarm list
An M198 or M99 command was executed during schedule operation. Alternatively, the
execution of an M198 command was attempted during DNC operation. Please correct the
program.
The execution of an M99 command was attempted by an interrupt macro during pocket
machining in a multiple repetitive cycle.
Number
Message
Contents
PS0213
ILLEGAL COMMAND IN SYNCHRO-MODE
In axis synchronous control, the following errors occurred during the synchronous operation.
The program issued the move command to the slave axis.
The program issued the manual operation (jog feed or incremental feed) to the slave axis.
The program issued the automatic reference position return command without specifying
the manual reference position return after the power was turned on.
While bit 1 (SFS) of parameter No. 7180 is set to 0, reference point setting with
mechanical stopper was attempted for the axis synchronous control. Set bit 1 (SFS) of
parameter No. 7180 to 1.
An attempt was made to select the slave axis manual handle feed axis selection signal for
the axis synchronous control and perform reference point setting with mechanical stopper.
Select the manual handle feed axis selection signal for the master axis in axis
synchronous control.
Number
Message
Contents
PS0217
DUPLICATE G51.2(COMMANDS)
G51.2 is further commanded in the G51.2 mode. Please correct the program.
Number
Message
Contents
PS0218
NOT FOUND P/Q COMMAND
P or Q is not commanded in the G51.2 block, or the command value is out of the range. Please
correct the program. For polygon machining with two spindles, more information as to why this
alarm occurred is indicated in diagnosis data No. 471.
Number
Message
Contents
PS0219
ILLEGAL COMMAND IN G96.1/G96.2/G96.3/G96.4
G51.2 and 50.2 were specified in the same block for other commands. Modify the program in
another block.
Number
Message
Contents
PS0220
ILLEGAL COMMAND IN SYNCHR-MODE
In the synchronous operation, movement is commanded by the NC program or PMC axis
control interface for the synchronous axis. Correct the program or check the PMC sequence
program.
Number
Message
Contents
PS0221
ILLEGAL COMMAND IN SYNCHR-MODE
An attempt was made to execute polygon turning synchronous operation at the same time with
Cs contouring control or balance cut. Please correct the program.
Number
Message
Contents
PS0224
ZERO RETURN NOT FINISHED
Reference return is not performed before automatic operation starts (only when bit 0
(ZRNx) of parameter No. 1005 = 0). Perform a reference position return.
Spindle positioning command was specified during spindle rotation mode. Switch to
spindle positioning mode and specify spindle positioning commands.
Number
Message
PS0230
R CODE NOT FOUND
325
Alarm list
B-64805EN/03
Contents
Cut depth R is not specified in the block including G161. Alternatively, the value specified for R
is negative.
Please correct the program.
Number
Message
Contents
PS0231
ILLEGAL FORMAT IN G10 L52
Errors occurred in the specified format at the programmable-parameter input.
Number
Message
Contents
PS0232
TOO MANY HELICAL AXIS COMMAND
Three or more axes were specified as helical axes in the helical interpolation mode. Four or
more axes (Series 502iS-A), or five or more axes (Series 501iS-A), were specified as helical
axes in the helical interpolation B mode.
Number
Message
Contents
PS0233
DEVICE BUSY
When an attempt was made to use a unit such as that connected via the RS-232C interface,
other users were using it.
Number
Message
Contents
PS0241
ILLEGAL FORMAT IN G02.2/G03.2
The end point of an involute curve on the currently selected plane, or the center coordinate
instruction I, J or K of the corresponding basic circle, or basic circle radius R was not specified.
Number
Message
Contents
PS0242
ILLEGAL COMMAND IN G02.2/G03.2
An illegal value was specified in the involute curve.
The coordinate instruction I, J or K of the basic circle on the currently selected plane or the
basic circle radius R is "0", or the start and end points are not inside the basic circle.
Number
Message
Contents
PS0243
OVER TOLERANCE OF END POINT
The end point is not positioned on the involute curve that passes through the start point, and
this error exceeds the permissible error limit (parameter No. 5610).
Number
Message
Contents
PS0245
T-CODE NOT ALLOWED IN THIS BLOCK
One of the G codes, G50, G10, G04, G28, G28.2, G29, G30, and G30.2,G30.1,G53, which
cannot be specified in the same block as a T code, was specified with a T code.
Number
Message
Contents
PS0247
THE MISTAKE IS FOUND IN THE OUTPUT CODE OF DATA.
When an encrypted program is output, EIA is set for the output code.
Specify ISO.
Number
Message
Contents
PS0250
TOOL CHANGE ILLEGAL Z AXIS COMMAND
A Z-axis move command was performed in the same block for M06 command.
Number
Message
Contents
PS0251
TOOL CHANGE ILLEGAL T COMMAND
An unusable T code was specified in M06T.
326
B-64805EN/03
Alarm list
Number
Message
Contents
PS0300
ILLEGAL COMMAND IN SCALING
An illegal G code was specified during scaling. Please correct the program.
For the T system, if one of the following functions is specified during scaling, this alarm is
generated (specify G codes for systems B and C in that order).
Finishing cycle (G70 or G72)
Outer surface or inner surface rough-cutting cycle (G71 or G73)
End side rough-cutting cycle (G72 or G74)
Closed loop cutting cycle (G73 or G75)
End side cutting-off cycle (G74 or G76)
Outer surface or inner surface cutting-off cycle (G75 or G77)
Multiple repetitive threading cycle (G76 or G78)
Face drill cycle (G83)
Face tapping cycle (G84)
Face boring cycle (G85)
Side drill cycle (G87)
Side tapping cycle (G88)
Side boring cycle (G89)
Outer surface turning cycle or inner surface boring cycle (G77 or G20)
Threading cycle (G78 or G21)
End side turning cycle (G79 or G24)
Number
Message
Contents
PS0301
RESETTING OF REFERENCE RETURN IS INHIBITED
For the reference position setting without DOG, an attempt was made to perform manual
reference position return although bit 0 (IDGx) of parameter No. 1012 was set to 1 to inhibit the
reference position from being set again.
Number
Message
Contents
PS0302
SETTING THE REFERENCE POSITION WITHOUT DOG IS NOT PERFORMED
The reference position could not be set with the reference position setting without DOG.
Causes of the alarm are as follows.
The axis was not moved in the direction of reference position return in jog feed.
The axis was moved in the direction opposite to the direction of manual reference position
return.
The manual reference position return grid was not established because the position
detector single rotation signal was not captured (requires bit 6 of diagnosis data No. 0201
to be “1”).
Number
Message
Contents
PS0303
REFERENCE RETURN INCOMPLETE
When the arbitrary position reference setting for CS axis is enabled (bit 0 (CRF) of parameter
No. 3700 = 1), a G00 command was specified for the Cs contour axis without reference
position return after the spindle was switched to Cs contouring control mode.
Perform an automatic reference position return with a G28 command before issuing a G00
command.
Number
Message
Contents
PS0304
G28 IS COMMANDED WITHOUT ZERO RETURN
Although a reference position was not established, reference position return (G28) was
commanded.
Number
Message
Contents
PS0305
INTERMEDIATE POSITION IS NOT ASSIGNED
Although a G28 (automatic return to the reference position), G30 (return to the second, third, or
fourth reference position), or G30.1 (floating reference position return) command was not
issued after power-up, G29 (move from the reference position) was specified.
327
Alarm list
B-64805EN/03
Number
Message
Contents
PS0306
MISMATCH AXIS WITH CNR/CHF
The correspondence between the moving axis and the I, J, or K command is incorrect in a
block in which chamfering is specified.
Number
Message
Contents
PS0307
CAN NOT START REFERENCE RETURN WITH MECHANICAL STOPPER SETTING
Reference position setting with mechanical stopper is being attempted for an axis which uses
the reference position setting without DOG function.
Number
Message
Contents
PS0310
FILE NOT FOUND
The specified file could not be found during a subprogram or macro call.
Number
Message
Contents
PS0311
CALLED BY FILE NAME FORMAT ERROR
1. An invalid format was specified to call a subprogram or macro using a file name.
2. An invalid format was specified to call a subprogram or macro using a file name via a
macro variable. Possible causes are:
Format is not “#MACRO VARIABLE NO.”
The macro variable number does not exist
The generated file name is longer than 32 characters
Number
Message
Contents
PS0312
ILLEGAL COMMAND IN DIRECT DRAWING DIMENSIONS PROGRAMMING
Direct drawing dimension programming was commanded in an invalid format.
An attempt was made to specify an invalid G code during direct drawing dimension
programming.
Two or more blocks not to be moved exist in consecutive commands that specify direct drawing
dimension programming.
Although non-use of commas (,) (bit 4 (CCR) of parameter No. 3405 = 1) was specified for
direct drawing dimension programming, a comma was specified.
Number
Message
Contents
PS0313
ILLEGAL LEAD COMMAND
In the variable-lead thread cutting, the increment specified in address K has exceeded the
specified max. programmable dimension. Or, a negative lead value was specified.
Number
Message
Contents
PS0314
ILLEGAL SETTING OF POLYGONAL AXIS
An axis was specified invalidly in polygon turning.
For polygon turning:
In parameter No. 7610, the tool rotation axes are not set.
When bit 2 (PDC) or bit 4 (PLP) of parameter No. 7600 is set to 1, exponential
acceleration/deceleration is set for the tool rotation axis acceleration/deceleration
type (bits 0 (CTLx) and 1 (CTBx) and of parameter No. 1610)
When bit 4 (PLP) of parameter No. 7600 is set to 1, bit 3 (PLROT) of parameter
No. 7603 is set to 1.
The tool rotation axis must be set as the rotary axis (type A). (Parameters
ROTx,ROSx (No.1006#0,#1))
For polygon machining with two spindles:
In parameters No. 7640 to 7643, valid axes are not set.
A spindle other than the spindle is specified.
A spindle is not connected.
For concurrent use of polygon turning and polygon turning with two spindles:
In the polygon turning mode, the value of parameter No. 7605 (selecting the type of
polygon turning) was changed.
328
B-64805EN/03
Alarm list
An attempt is made to use a spindle used for polygon turning also for polygon
machining with two spindles.
Number
Message
Contents
PS0315
ILLEGAL NOSE ANGLE COMMAND IS IN THE THREAD CUTTING CYCLE
An invalid tool tip angle is specified in a threading cycle of a multiple repetitive cycle (G76).
Number
Message
Contents
PS0316
MOVEMENT AMOUNT/CUTTING AMOUNT IN THE DRILLING CYCLE IS ZERO
The Δi or Δk (travel distance/cut depth) is set to 0 in a rough-cutting cycle of a multiple
repetitive cycle (G74 or G75) despite a value other than 0 being specified for U or W.
Number
Message
Contents
PS0317
ILLEGAL THREAD COMMAND IS IN THE THREAD CUTTING CYCLE
A zero or a negative value is specified in a threading cycle of a multiple repetitive cycle (G76)
as the thread height or the depth of cut.
Number
Message
Contents
PS0318
ILLEGAL RELIEF AMOUNT IS IN THE DRILLING CYCLE
Although an escape directions is set in a rough-cutting cycle of a multiple repetitive cycle (G74
or G75), a negative value is specified for Δd.
Number
Message
Contents
PS0319
MOVEMENT AMOUNT/CUTTING AMOUNT IN THE DRILLING CYCLE IS ZERO
The Δi or Δk (travel distance/cut depth) is set to 0 in a rough-cutting cycle of a multiple
repetitive cycle (G74 or G75) despite a value other than 0 being specified for U or W.
Number
Message
Contents
PS0320
ILLEGAL MOVEMENT AMOUNT/CUTTING AMOUNT IS IN THE DRILLING CYCLE
The Δi or Δk (travel distance/cut depth) is specified as a negative value in a rough-cutting cycle
of a multiple repetitive cycle (G74 or G75).
Number
Message
Contents
PS0321
ILLEGAL REPEATED TIME IS IN THE PATTERN REPEATING CYCLE
A zero or a negative value is specified in a closed loop cutting cycle of a multiple repetitive
cycle (G73) as a repeated time.
Number
Message
Contents
PS0322
FINISHING SHAPE WHICH OVER OF STARTING POINT
An invalid shape which is over the cycle starting point is specified in a shape program for a
rough-cutting cycle of a multiple repetitive cycle (G71 or G72).
Number
Message
Contents
PS0323
THE FIRST BLOCK OF SHAPE PROGRAM IS A COMMAND OF TYPE II
Type II is specified in the first block of the shape program specified by P in a rough-cutting
cycle of a multiple repetitive cycle (G71 or G72).
Z (W) command is for G71.
X (U) command is for G72.
Number
Message
Contents
PS0324
THE INTERRUPTION TYPE MACRO WAS DONE IN THE MULTIPLE REPETIVE CYCLES
An interruption type macro was issued during the multiple repetitive cycle (G70, G71, G72, or
G73).
329
Alarm list
B-64805EN/03
Number
Message
Contents
PS0325
UNAVAILABLE COMMAND IS IN SHAPE PROGRAM
An unusable command was issued in a shape program for a multiple repetitive cycle
(G70, G71, G72, or G73).
In the multiple repetitive cycle (G70), when the tool nose radius compensation can be
commanded in the target figure program (parameter NT2(No.5106#3)=1), G41 or G42 is
commanded at the target figure program other than the first block.
Number
Message
Contents
PS0326
LAST BLOCK OF SHAPE PROGRAM IS A DIRECT DRAWING DIMENSIONS
In a shape program in the multiple repetitive cycle (G70, G71, G72, or G73), a command for
direct drawing dimension programming in the last block is terminated in the middle.
Number
Message
Contents
PS0327
MODAL THAT MULTIPLE REPETIVE CYCLES CANNOT BE DONE
A multiple repetitive canned cycle (G70, G71, G72, or G73) was commanded in a modal state
in which a multiple repetitive cycle could not be commanded.
Number
Message
Contents
PS0328
ILLEGAL WORK POSITION IS IN THE TOOL NOSE RADIUS COMPENSATION
The specification for the blank side for a tool nose radius compensation (G41 or G42) is
incorrect in a multiple repetitive cycle (G71 or G72).
Number
Message
Contents
PS0329
THE FINISHING SHAPE IS NOT A MONOTONOUS CHANGE(SECOND AXES)
In a shape program for a rough-cutting cycle of a multiple repetitive cycle (G71 or G72), the
command of the second plane axis was not a monotonous increase or decrease.
Number
Message
Contents
PS0330
ILLEGAL AXIS COMMAND IS IN THE TURNING CANNED CYCLE
An axis other than the plane is specified in a canned cycle (G90, G92, or G94).
Number
Message
Contents
PS0331
ILLEGAL AXIS NUMBER IN AX[]
An illegal value is specified for an AX [ ] axis number.
Number
Message
Contents
PS0332
ILLEGAL AXIS ADDRESS IN AXNUM FUNCTION
An illegal axis address is specified for an AXNUM function.
Number
Message
Contents
PS0333
TOO MANY SPINDLE COMMANDS
Multiple spindle commands exist in the same block when using spindle name expansion.
Only one spindle could be commanded in the same block.
Number
Message
Contents
PS0334
INPUT VALUE OUT OF EFFECTIVE RANGE
An offset data which was out of the effective range was specified (wrong operation prevention).
Number
Message
Contents
PS0335
PLURAL M CODE
Multiple M codes are commanded simultaneously in a block for a wait function with peripheral
devices by an M code.
330
B-64805EN/03
Alarm list
Number
Message
Contents
PS0336
TOOL COMPENSATION COMMANDED MORE TWO AXES
For a tool length compensation C, an attempt was made to command the offset to other axes
without canceling the offset. Or, for a tool length compensation C, multiple axes are specified in
G43 or G44 block.
Number
Message
Contents
PS0337
EXCESS MAXIMUM INCREMENTAL VALUE
The command value exceeded the maximum amount of incremental (wrong operation
prevention).
Number
Message
Contents
PS0345
TOOL CHANGE ILLEGAL Z AXIS POS
TOOL CHANGE ILLEGAL Z AXIS POS
Number
Message
Contents
PS0346
TOOL CHANGE ILLEGAL TOOL NUM
A tool change position is not set.
Number
Message
Contents
PS0347
TOOL CHANGE ILLEGAL COMMAND IN SAME BLK.
TOOL CHANGE ILLEGAL COMMAND IN SAME BLK.
Number
Message
Contents
PS0348
TOOL CHANGE Z AXIS POS NOT ESTABLISHED
TOOL CHANGE Z AXIS POS NOT ESTABLISHED
Number
Message
Contents
PS0349
TOOL CHANGE SPINDLE NOT STOP
TOOL CHANGE SPINDLE NOT STOP
Number
Message
Contents
PS0365
TOO MANY MAXIMUM SV/SP AXIS NUMBER PER PATH
The maximum designation of spindle axes usable in one path, or the maximum designation of
spindle axes was exceeded (in case of a loader path, when the number of axes for 1 path is set
to more than 5, this alarm is generated).
Number
Message
Contents
PS0366
IMPROPER G-CODE IN TURRET METHOD
When the turret change tools method was selected (bit 3 (TCT) of parameter No. 5040 = 0),
G43, G43.1, G43.4, G43.5, or G43.7 was commanded.
Number
Message
PS0367
3-D CONV. WAS COMMANDED IN SYNC MODE AS THE PARAMETER PKUx(NO.8162#2)
IS 0.
3-dimensional coordinate conversion was commanded during synchronization control when the
bit 2 (PKUx) of parameter No. 8162 was 0.
Contents
Number
Message
PS0368
OFFSET REMAIN AT OFFSET COMMAND
331
Alarm list
Contents
B-64805EN/03
When the ATC change tools method was selected (bit 3 (TCT) of parameter No. 5040 = 1)
during G43, G43.1, G43.4, or G43.5 mode, G43.7 was commanded. Or, G43, G43.1,
G43.4, or G43.5 was commanded during G43.7 mode.
After bit 3 (TCT) of parameter No. 5040 was changed in the state in which a tool offset
remained, another tool offset was specified.
Number
Message
Contents
PS0369
G31 FORMAT ERROR
No axis is specified or two or more axes are specified in the torque limit skip command
(G31 P98/P99).
The specified address Q value in the torque limit skip command is out of range. The
torque Q range is 1 to 254.
The continuous high-speed skip function is not available.
Number
Message
Contents
PS0370
G31P/G04Q ERROR
The specified address P value for G31 is out of range. Address P ranges from 1 to 4 in the
multi-step skip function.
The specified address Q value for G04 is out of range. Address Q ranges from 1 to 4 in
the multi-step skip function.
P1-4 at G31 and Q1-4 at G04 were commanded even though there is no multi-step skip
function.
<T series > The specified value of address P of G72 or G74 falls outside the range.
Address P ranges from 1 to 4 in the multi-step skip function. P1-4 was specified in G72 or
G74 even though the multi-step skip function is not available.
Number
Message
Contents
PS0371
ILLEGAL FORMAT IN G10 OR L50
In a command format for a programmable parameter input, parameters for an encryption (No.
3220), a key (No. 3221), or a protection range (No. 3222 or No. 3223) ("key and program
encryption function") were changed. Please correct the program.
Number
Message
Contents
PS0372
REFERENCE RETURN INCOMPLETE
When an automatic reference position return was attempted while a manual reference position
return during angular axis control or reference position return after power-up is not performed,
an attempt was made to perform an automatic reference position return on the perpendicular
axis before the completion of a reference position return on the angular axis. First, complete
reference position return on the angular axis, then perform reference position return on the
perpendicular axis.
Number
Message
Contents
PS0373
ILLEGAL HIGH-SPEED SKIP SIGNAL SELECTED
In the skip commands (G31, G31P1 to G31P4) and dwell commands (G04, G04Q1 to G04Q4),
the same high-speed skip signal is selected in different paths.
Number
Message
Contents
PS0374
ILLEGAL REGISTRATION OF TOOL MANAGER(G10)
G10 L75 or G10 L76 data was registered during the following data registration:
From the PMC window.
From the FOCAS3.
By G10 L75/L76 in another path.
Command G10 L75 or G10 L76 again after the above operation is completed.
Number
Message
Contents
PS0375
CAN NOT ANGULAR CONTROL(SYNC:MIX:OVL)
Angular axis control is disabled for this axis configuration.
332
B-64805EN/03
Alarm list
When axes relevant to angular axis control are not in the synchronous control mode or
when one angular axis is not paired with the other angular axis or one Cartesian axis is
not paired with the other Cartesian axis in synchronous control.
When axes relevant to angular axis control are not in the composite control mode or when
one angular axis is not paired with the other angular axis or one Cartesian axis is not
paired with the other Cartesian axis in composite control.
When related axes under angular axis control is switched to superimposed control mode.
Number
Message
Contents
PS0376
SERIAL DCL: ILLEGAL PARAMETER
When bit 1 (OPTx) of parameter No. 1815 of the separate position detector is enabled, the
bit 3 of parameter No. 2002 is disabled.
Bit 5 (APCx) of parameter No. 1815 of the absolute position detector is enabled.
Number
Message
Contents
PS0377
ILLEGAL MODE FOR GOTO/WHILE/DO
GOTO, WHILE, and DO statements cannot be executed with the program created in MDI
mode. When executing a program that includes these, register that program in the program
memory and execute the program via a call.
Number
Message
Contents
PS0387
ILLEGAL RTM DI/DO VAR
There is no DI/DO variable that has a specified signal address (alphabet, number).
Number
Message
Contents
PS0388
CANNOT GET MACRO VAR
Motion Script cannot obtain information about the specified macro variable.
Number
Message
Contents
PS0389
ILLEGAL RTM SIGNAL BIT
Bits other than bits 0 to 7 cannot be specified with a DI/DO signal.
Number
Message
Contents
PS0390
MACRO VAR. NOT SUPPORTED
A macro variable which was not supported by the Motion Script was used.
Number
Message
Contents
PS0391
RTM BRANCH OVER
The number of branches supported with real time custom macros was exceeded.
Number
Message
Contents
PS0392
TOO MANY SENTENCE CONTROL
Many reserved words (ZONCE, ZEDGE, ZWHILE, ZDO, ZEND, G65, M99) for RTM control
were used in a real time macro command.
Number
Message
Contents
PS0393
NO SENTENCE CONTROL
In a real time macro command, there is no data to be assigned.
Number
Message
Contents
PS0394
ILLEGAL SENTENCE CONTROL
The correspondence of the reserved words controlling RTM
(ZONCE, ZEDGE, ZWHILE, ZDO, ZEND, G65, M99) is erroneous.
333
Alarm list
B-64805EN/03
Number
Message
Contents
PS0395
ILLEGAL NC WORD CONTROL
G65 and M99 of a subprogram call or return control from a subprogram are not correctly
described (Motion Script).
Number
Message
Contents
PS0396
ILLEGAL RTM SENTENCE CONTROL
In other than a real time macro command, a reserved word (ZONCE, ZEDGE, ZWHILE, ZDO,
or ZEND) for RTM control is used.
Number
Message
Contents
PS0397
RTM BUFFER OVER
There is no buffer available for real time macro commands. Too many blocks read in advance
are buffered as triggers used by real time macro commands.
Number
Message
Contents
PS0398
ID EXCEEDED
In blocks read in advance, there are too many Motion Script commands with the same ID.
Number
Message
Contents
PS0399
ID EXECUTION IN SAME TIME
An attempt was made to execute Motion Script commands with the same ID by using the same
NC statement as a trigger.
Number
Message
Contents
PS0400
ONE SHOT COMMAND OVER
Too many one-shot Motion Script commands are specified.
Number
Message
Contents
PS0401
EXEC CMD NUM OVER IN SAME TIME
The number of Motion Script commands that can be executed simultaneously was exceeded.
Number
Message
Contents
PS0402
ILLEGAL TOKEN FOR RTM
A token, variable, or function that is not supported by the real time custom macro function was
detected.
Number
Message
Contents
PS0403
ACCESS TO RTM PROTECT VAR
An attempt was made to access a protected variable.
Number
Message
Contents
PS0404
MotionScript CMD ERROR
An error related to a Motion Script command occurred.
Number
Message
Contents
PS0406
CODE AREA SHORTAGE
The storage size of the Motion Script command is insufficient.
Number
Message
Contents
PS0407
DOULE SLASH IN RTM MODE
In the compile mode, an attempt was made to set the compile mode again.
334
B-64805EN/03
Alarm list
Number
Message
Contents
PS0408
CANNOT SPECIFY ABSOLUTE COMMAND
Absolute commands cannot be specified (Motion Script).
Number
Message
Contents
PS0409
ILLEGAL AXIS NO
Axis number is incorrect (Motion Script).
Number
Message
Contents
PS0410
MIDDLE POINT IS NOT ZERO
The intermediate position of G28 is specified to a value other than "0" (Motion Script).
Number
Message
Contents
PS0411
Motion Script has exceeded the number of axes that can be commanded in one block
Motion Script has exceeded the number of axes that can be commanded in one block
Number
Message
Contents
PS0412
ILLEGAL G CODE
An unusable G code was used.
Number
Message
Contents
PS0413
ILLEGAL ADDRESS
An unusable address was used.
Number
Message
Contents
PS0415
GROUP IS IN USE
The group to which the specified axis belongs is already in used.
Number
Message
Contents
PS0416
UNABLE TO USE THE AXIS
The specified axis cannot be used.
Number
Message
Contents
PS0417
AXIS IS UNABLE TO MOVE
The axis control Motion Script was executed in the following states. Resolve the alarm and
abnormal load states. When alarm signal EIALg is “1”, enter reset signal ECLRg to set it to “0”.
The target axis is in a PMC axis control alarm state (alarm signal EIALg is “1”)
Emergency stop
Servo motor, spindle motor, overtravel, and power off alarm state (SV, SP, OT, and PW
alarms)
The target axis is detecting an abnormal load in the unexpected disturbance torque
detection function.
Number
Message
Contents
PS0418
ILLEGAL FEED SETTING
An incorrect feedrate is set.
Number
Message
Contents
PS0419
ILLEGAL DISTANCE SETTING
A travel distance beyond the specifiable range is specified.
335
Alarm list
B-64805EN/03
Number
Message
Contents
PS0420
CONSTANT NUMBER P
A subprogram is specified not by using a constant.
Number
Message
Contents
PS0421
ILLEGAL ARGUMENT G65
With G65, an invalid argument, L, is used.
Number
Message
Contents
PS0422
ILLEGAL ARGUMENT G65
With G65, an invalid argument is used.
Number
Message
Contents
PS0423
NO PMC AXIS CONTROL OPTION
The option for PMC axis control is missing.
Number
Message
Contents
PS0424
MULTIPLE AXES IN ONE GROUP
Multiple axes are using one group.
Number
Message
Contents
PS0426
M FUNCTION IS UNABLE TO USE
An auxiliary function was specified with a one-shot Motion Script command.
The group number usable for the modal Motion Script command ID is not set.
Number
Message
Contents
PS0427
ILLEGAL M CODE
An M code above M00, M01, M02, M30, M98, M198, M65536 was specified.
Multiple M codes were specified in a single block. (Motion Script)
Number
Message
Contents
PS0428
AUX FUNCTION IS IN USE
The auxiliary function is used by the Motion Script or PMC axis control.
Number
Message
Contents
PS0430
TOOL LIFE PAIRS ZERO
Tool life management group number parameter No.6813 is 0.
Number
Message
Contents
PS0431
ILLEGAL T/R DATA OF TOOL LIFE
The arbitrary group number (T) or remaining amount setting (R) is invalid.
Number
Message
Contents
PS0436
ILLEGAL PARAMETER IN WSC
An incorrect parameter was specified in workpiece setting error compensation.
In parameter No. 1022, the basic three axes are not set.
Number
Message
Contents
PS0437
ILLEGAL COMMAND IN WSC
An invalid command related to workpiece setting error compensation was specified.
An illegal G code was specified in the workpiece setting error compensation mode.
336
B-64805EN/03
Alarm list
There is an error in the modal setting used when the workpiece setting error
compensation is started.
G54.4 was not specified independently.
There is not the P command in the block including the G54.4 command. Alternatively, the
value following P is out of the range.
Workpiece setting error compensation was specified redundantly.
Number
Message
Contents
PS0438
ILLEGAL PARAMETER IN TOOL DIRC CMP
If, on a 5-axis machine, either of the two cases below applies, a parameter is illegal.
The setting is such that tool direction compensation is performed if workpiece setting error
compensation is performed (bit 0 (RCM) of parameter No. 11200 = 1).
Tool center point retention type tool axis direction control (G53.6) is performed.
Acceleration/deceleration before interpolation is disabled. Set parameter No.
1660.
Rapid traverse acceleration/deceleration before interpolation is disabled. Set bit 1
(LRP) of parameter No. 1401, bit 5 (FRP) of parameter No. 19501, and
parameters No. 1671.
One of parameters Nos.19680 to 19714 used to configure the machine contains
an error.
The axis specified with parameter No. 19681 or No. 19686 is not a rotary axis.
In parameter No. 1022, the basic three axes are not set.
When applying tool length compensation during workpiece setting error
compensation, bit 6 (TOS) of parameter No. 5006 is 0 and bit 2 (TOP) of
parameter No. 11400 is 0. Set either parameter to 1.
Number
Message
Contents
PS0439
ILLEGAL COMMAND IN TOOL DIRC CMP
When workpiece setting error compensation was applied in a 5-axis machine tool (setting to
apply compensation in the tool direction (bit 0 (RCM) of parameter No. 11200 is 1)), an illegal
command was issued.
An unspecifiable G code was specified.
There is an error in the modal setting used during startup.
An axis not related to 5-axis machining was specified.
The absolute coordinates of a rotation axis could not be obtained in the startup block of
workpiece setting error compensation or tool center point control.
Number
Message
Contents
PS0441
DUPLICATE PATH TABLE
Multiple path tables exist that correspond to the executed table number.
Ex.
<AXIS_TABLE_1234_X1> and <TIME_TABLE_1234_X1> exist.
<AXIS_TABLE_0001_M> and <TIME_TABLE_0001_M> exist.
Number
Message
Contents
PS0442
PATH TABLE COMMAND EXCES ERR
At the start of the Path Table Operation, the difference between the actual axis position
and the start command at the Path Table exceeds the parameter No.11101.
At the start of the Path Table Operation, the difference between the actual spindle speed
and the start command of spindle speed at the Path Table exceeds the parameter
No.11102.
Number
Message
Contents
PS0443
PTRDY SIGNAL IS OFF
Even though the Path Table Ready signal PTRDY <Fn519.6> is "0", the Path Table Operation
is started. Retry Path Table Operation after Path Table conversion.
Number
PS0444
337
Alarm list
B-64805EN/03
Message
Contents
ILLEGAL PATH TABLE M-CODE
M/P/Q code for starting the Path Table operation is not correct There in an error in the address
P or Q commands. Please correct the program.
Number
Message
Contents
PS0445
ILLEGAL AXIS OPERATION
The positioning command was issued in the speed control mode. Check the SV speed control
mode in-progress signal.
Number
Message
Contents
PS0446
ILLEGAL COMMAND IN G96.1/G96.2/G96.3/G96.4
G96.1, G96.2, G96.3, and G96.4 are specified in the block that includes other commands.
Please correct the program.
Number
Message
Contents
PS0447
ILLEGAL SETTING DATA
The live tool axis is incorrectly set. Check the parameters of the spindle control function by
servo motor or the spindle control by Cs contouring control.
Number
Message
Contents
PS0451
ILLEGAL AUXILIARY FUNCTION TABLE COMMAND
When M code is output in the auxiliary function table, the PMC sequence program does not
execute the completion processing of the previous M code.
Number
Message
Contents
PS0452
ILLEGAL PATH TABLE OPERATION
In Path Table Operation, the following problems occurred.
Skip command is not correct.
The connection of the Path Table is not correct.
Path Table Operation is not correct for other reason, etc.
Detailed alarm numbers cannot be read by the cnc_rdptexedistalm function in FOCAS3.
Number
Message
Contents
PS0453
TOO MANY AXES ARE COMMANDED IN PATH TABLE OPERATION
A movement command that is greater than the number of contouring control axes was issued
during path table operation.
Number
Message
Contents
PS0455
ILLEGAL COMMAND IN GRINDING
In the canned grinding cycle:
<M series> The signs of the I, J, and K commands do not match.
<M series/T series > The amount of travel of the grinding axis is not specified.
Number
Message
Contents
PS0456
ILLEGAL PARAMETER IN GRINDING
Parameters related to canned grinding cycles are incorrectly set. Causes of the alarm are as
follows.
<M series/T series> The axis number of the grinding axis is incorrectly set (parameters
Nos. 5176 to 5179).
<M series> The axis number of the dressing axis is incorrectly set (parameters Nos. 5180
to 5183).
<M series/T series> The axis numbers of the cut axis, grinding axis, and dressing axis
(only for the M series) overlap.
Number
PS0459
338
B-64805EN/03
Alarm list
Message
Contents
ALL PARALLEL AXES IN PARKING
All the axes specified during automatic operation are parking.
Number
Message
Contents
PS0460
ILLEGAL TORCH AXIS NUMBER
The axis number set in parameter No. 5490 (torch control axis) exceeds the number of
controlled axes.
Number
Message
Contents
PS0461
ILLEGAL SETTING OF ROTATE AXIS OF TORCH
The parameter setting (bit 0 (ROTx) of parameter No. 1006 = 1) of the rotation axis is not
applied to the torch turning axis.
Number
Message
Contents
PS0492
3DCHK FIG. ILLEGAL: [Target name]
The figure data of [Target name] specified for the built-in 3D interference check is invalid.
For tool holder: the holder number of the tool geometry size data is not set.
For tool: the tool tip direction is not set in the tool holder figure setting screen.
Number
Message
Contents
PS0493
3DCHK AXIS ILLEGAL: [Target name]
The move axis data of [Target name] specified for the built-in 3D interference check is invalid.
Number
Message
Contents
PS0494
3DCHK FUNCTION INVALID
The built-in 3D interference check function is disabled by bit 0 (ICE) of parameter No. 10930.
Number
Message
Contents
PS0495
3DCHK TOO MANY FIGURE
The total number of figures included in all interference check targets except the tool exceeds
23.
Number
Message
Contents
PS0496
ILLEGAL P,Q COMMAND IN G22.2
For G22.2 command, parameter P or Q is out of range or not specified. Modify the program.
Number
Message
Contents
PS0497
CANNOT MAKE TOOL FIGURE BY TOOL MANAGEMENT
According to bit 2 (ICT) of parameter No.10930, though the tool figure should be automatically
made by using the tool management function, the option for the tool management function is
not available.
Number
Message
Contents
PS0501
THE COMMANDED M-CODE CAN NOT BE EXECUTED.
The M code specified in parameter No. 11631 to 11646 was specified in other than an
execution macro, macro interrupt, macro call using a G or M code, or subprogram call using a
T, S, or second auxiliary function code.
Number
Message
Contents
PS0507
ILLEGAL PARAMETER(NO.7526)
The address of the R signal for the high-speed cycle cutting operation information output
function is invalid.
The specified R signal address is invalid.
The start address is not a multiple of 4 (0, 4, 8, ...).
339
Alarm list
B-64805EN/03
A 36-byte area is not allocated.
Number
Message
Contents
PS0508
G code to need G90(PAC)
In parallel axis control, a G code requiring an absolute command (G90) in the block
immediately before was specified.
Number
Message
Contents
PS0509
TOOL OFFSET COMMAND IS NOT AVAILABLE
Tool offset (for the lathe system) was specified in the thread cutting block.
Tool offset was specified (lathe system) in the scaling mode, coordinate system rotation
mode, or programmable mirror image mode.
Number
Message
Contents
PS0511
CS HI-SPEED SWITCHING FORMAT ERROR
The format of Cs contouring control high speed switching is invalid.
Number
Message
Contents
PS0512
IMPOSSIBLE COMMAND FOR CS HI-SPEED SWITCHING
The following commands cannot be specified in Cs contouring control high speed switching:
Move command not for high-speed cycle cutting
Synchronous/composite control, superimposed control
Spindle command synchronous control
Simple spindle electronic gear box
Manual reference position return
Number
Message
Contents
PS0513
CS HI-SPEED SWITCHING SETTING ERROR
The setting for Cs contouring control high speed switching is invalid. Causes of the alarm are
as follows.
An M code value for Cs contouring control high speed switching is used for multiple Cs
contour control axes.
FIN is returned for the M code for high-speed switching of Cs contouring control when the
Cs contouring control high speed switching completion signal CSMCx does not become 1.
The spindle software does not support the spindle control switching function for highspeed cycle cutting.
Number
Message
Contents
PS0517
SETTING ERROR AMOUNT IS OUT OF RANGE
An attempt was made to start workpiece setting error compensation when a rotation direction
setting error was outside the range set in the corresponding parameter No. 11753 to 11758.
Number
Message
Contents
PS0518
CODE OF CONTROL-IN DOES NOT EXIST
No code of control-in ")" acting as a comment end symbol exists in the inputted program.
Number
Message
Contents
PS0519
PROGRAM FILES ARE BROKEN AND CLEARED
The program was completely cleared due to being broken.
The power to the CNC may have been disconnected during program batch writing to the
nonvolatile memory.
Number
Message
Contents
PS0522
ILLEGAL CMD. IN RATE FEED(G93.2)
Interpolation other than linear or circular interpolation is commanded in rate feed.
340
B-64805EN/03
Alarm list
Number
Message
Contents
PS0524
PARAMETER CHANGE ERROR
In the hypothetical linear axis control, parameter No. 13281 or No. 13284 had been changed.
However the hypothetical coordinate system setting was not executed because of the following
cause.
Automatic operation is stopped.
Number
Message
Contents
PS0525
SUB PROGRAM/MACRO CALLING
The mode was changed and cycle start was executed during subprogram/macro calling.
Perform cycle start again after resetting.
Number
Message
Contents
PS0526
ILLEGAL PARAMETER IN HLAC
The setting of the parameter of hypothetical linear axis control function is illegal. Check the
following parameters and set to be 2 hypothetical axes, a real rotary axis and a real linear axis
in the hypothetical plane.
(No.1006#0)
(No.1023)
(No.11802#4)
(No.13280)
Number
Message
Contents
PS0527
ILLEGAL DATA IN PITCH ERROR
In the pitch error compensation points that have been decided by the setting of the parameters
to require checking, there is data whose difference between two consecutive compensation
points is outside the range of -128 to +127.
Please correct the pitch error compensation data or change the parameter.
Number
Message
Contents
PS0528
THREADING FORMAT ERROR
The format of arbitrary speed threading is invalid.
Number
Message
Contents
PS0529
THREADING COMMAND IMPOSSIBLE
The following commands cannot be specified in arbitrary speed threading mode.
Threading command except for threading (G32), threading cycle (G92), and
multiple threading cycle (G76, G76.7).
Taper angle is smaller than that of the last block (continuous threading).
Chamfering angle is smaller than the taper angle (thread cutting cycle).
Infeed axis cannot be decelerated to 0 with acceleration which is calculated
automatically in continuous threading.
Synchronous/composite control, superimposed control
Manual reference position return
Spindle command synchronous control
Simple spindle electronic gear box
Arbitrary speed threading is specified in Cs contouring control.
Spindle software does not support arbitrary speed threading.
Cs contouring control change signal is not set to "0" after resetting CNC in arbitrary speed
threading mode.
Number
Message
Contents
PS0530
EXCESS VELOCITY IN THREADING
In arbitrary speed threading, the axis feedrate exceeded the maximum cutting feedrate.
Number
PS0531
341
Alarm list
B-64805EN/03
Message
Contents
THREADING PARAMETER ERROR
Parameter setting for arbitrary speed threading is invalid.
Causes of the alarm are as follows.
An M code value to start arbitrary speed threading is used for multiple Cs contouring
control axes.
An M code value to cancel arbitrary speed threading is used for multiple Cs contouring
control axes.
Acceleration of feed axis (parameter No.11492) is smaller than that of spindle (Cs
contouring control axis) (parameter No.11030 to No.11032, No.25710 to No.25712).
Number
Message
Contents
PS0532
RE-MACHINING OF THREAD CUTTING IMPOSSIBLE
Re-machining thread cutting cannot be executed.
Causes of the alarm are as follows.
Groove of thread is not measured.
Measured data is outside of threading path.
Mirror image is applied to the first axis on the plane or the second axis on the plane.
Number
Message
Contents
PS0533
ILL. PARAM IN HIGH-SPEED S-TCP
A parameter related to smooth control (G43.4 P3, G43.5 P3, G43.8 P3, G43.9 P3) is illegal.
When setting the following, smooth control was commanded.
Reference angle RA, RB (parameter No.19698, 19699)
Number
Message
Contents
PS0535
TL OFS CONVERSION SETTING ERROR
In the following cases, this alarm will be generated when G44.1 has been specified.
The rotary axis is not set to the swivel head axis (bit 0 of parameter No. 19640).
The same rotary axis is set to both the tool nose rotation axis and the swivel head axis.
The axis direction of the tool nose rotation axis is not X-axis or Z-axis.
The axis direction of the swivel head axis is not Y-axis.
The number of axis for converted offset is short (No.1022).
Bit 7 (TTD) of parameter No. 19640 is 1, and the swivel head axis direction and the
reference tool axis direction are the same.
Number
Message
Contents
PS0536
ILLEGAL COMMAND IN G44.1
An illegal command is specified in the tool offset conversion function.
An offset number is not commanded in G44.1 block.
Even if the imaginary tool nose direction is commanded in G44.1 block, the commanded
value is not in range of 1 to 8.
The offset number is specified by D code that is different from the offset number specified
by H code in G44.1 mode (M series only).
A G code which is not allowed is specified at G44.1 block.
The rotation of the tool nose rotation axis or the swivel head axis is specified in G44.1
block.
The rotation of the tool nose rotation axis or the swivel head axis is specified in the block
in which basic three axes movement are commanded.
In G44.1 mode, even if the rotary axis that is used in calculation of the tool offset
conversion function is moved, G44.1 was not commanded again before offset axis is
moved.
G44.1 was specified in the following modes:
Tool center point control
Workpiece setting error compensation
Because the X axis is a program coordinate system switching axis, it cannot be used
together with program coordinate system switching.
Number
Message
PS0537
ILLEGAL COMMAND IN G91.2
342
B-64805EN/03
Alarm list
Contents
An invalid command was issued in a one-shot incremental command (G91.2).
A G code that cannot be commanded at the same time as G91.2 was commanded.
Number
Message
Contents
PS0538
OFFSET IS NOT CANCELED
When the tool nose radius compensation can be commanded in the figure program of the
finishing cycle of the multiple repetitive cycle (G70) (bit 3 (NT2) of parameter No. 5106 = 1),
G40 is not commanded at the end block in the figure program.
Number
Message
Contents
PS0539
MAX SP SPEED CLAMP COMMAND ERROR
Clamp of maximum spindle speed is illegal. Clamp of maximum spindle speed cannot be
specified for spindle name expansion.
Number
Message
Contents
PS0542
ILLEGAL PATH BY MANUAL ABSOLUTE
Tool path might become incorrect by manual absolute ON.
Please insert the absolute command before G02/G03.
Number
Message
Contents
PS0543
FSC PARAMETER SETTING ERROR
The slave axis specified with G81 is not set as a rotary axis. (bit 0 (ROTx) of parameter
No. 1006)
Number of pulses per rotation (parameter No. 7782 or 7783) is not set.
The group number of flexible synchronization control to which slave axis used with feed
per revolution belongs to is not correctly set.
Number
Message
Contents
PS0545
PRESSURE AND POSITION CONTROL COMMAND IS ILLEGAL
The pressure and position control commands (G14.1, G14.2, and G14.4) have not been
specified correctly.
Causes of the alarm are as follows.
The format is invalid.
This modal G code is not possible when specifying pressure and position control mode.
An illegal axis was specified.
Number
Message
Contents
PS0546
PRESSURE AND POSITION CONTROL MODE OFF
The pressure and position control command (G14.2) was specified during pressure and
position control mode OFF.
Number
Message
Contents
PS0547
IMPROPER G-CODE (PRESSURE AND POSITION CONTROL)
An illegal G code was specified during pressure and position control mode.
Number
Message
Contents
PS0549
CANNOT CHANGE PLANE(DRILL MODE)
A plane selection command is specified during drilling mode of canned cycle for drilling. Modify
the program.
Number
Message
Contents
PS0550
CANNOT DRILL CYCLE IN PLANE CONV
Canned cycle for drilling was specified during plane conversion by the plane conversion
function. Modify the program.
343
Alarm list
B-64805EN/03
Number
Message
Contents
PS0552
SP-MODE CHANGE COMMAND ERROR
The spindle control mode changing command is illegal. Causes of the alarm are as follows.
Spindle control mode changing is commanded for an invalid spindle.
Multiple M commands are commanded in spindle orientation ON/OFF command or Cs
contouring control ON/OFF command.
Illegal G code (G53, G54) is commanded at the spindle control mode changing block.
Number
Message
Contents
PS0553
SP-MODE CHANGE IMPOSSIBLE
Cannot execute spindle control mode changing command. Causes of the alarm are as follows.
Spindle control mode changing by program command is commanded during spindle
orientation or Cs contouring control by DI signal.
During spindle control mode changing, spindle control mode changing is commanded
from other paths.
Spindle control mode changing is commanded when spindle control mode off signal
MDOFF1 to MDOFF4<Gn586.4 to Gn586.7> is "1".
Number
Message
Contents
PS0554
S-CODE IS NOT COMMANDED
M03/M04 was commanded independently without S code.
Number
Message
Contents
PS0555
P2ACC MODE ON ERROR
The format of the cross rail axis control command is incorrect.
The parameter setting during cross rail axis control mode ON is incorrect.
The modal G code cannot specify cross rail axis control.
The reference point of the master or slave axis is not established.
Number
Message
Contents
PS0556
P2ACC ILLEGAL COMMAND
An illegal G code was specified during cross rail axis control mode.
A command to the master or slave axis was specified during cross rail axis control mode.
A command to a hypothetical axis was specified during cross rail axis control mode OFF.
Number
Message
Contents
PS0557
ILLEGAL FEEDRATE IN THREADING
Feedrate fluctuation was detected during thread cutting.
Alarm
Message
Contents
PS0563
CANNOT USE PMC AXIS (ADFF)
When using PMC axis control (advanced preview feedforward is enabled) for axes relevant to
the following functions, set the relevant paths to superimposed-ahead mode.
Composite control
Superimposed control
Number
Message
Contents
PS0564
ILLEGAL COMMAND OF SMART RTAP
The command for smart rigid tapping is illegal. Causes of the alarm are as follows.
The moving distance of the feed axis is larger than 4096 times of the screw pitch.
The used spindle software does not support smart rigid tapping.
Number
Message
Contents
PS0566
DRILLING AXIS IS NOT COMMANDED
Although bit 6 (DNC) of parameter No. 5160 is 1, the drilling axis is not specified in the drilling
canned cycle command block. Modify the program.
344
B-64805EN/03
Alarm list
Number
Message
Contents
PS0568
NO WORK COORDINATE SYSTEM PRESET
The axis controlled by the PMC axis was issued an NC command without workpiece coordinate
system preset (G92.1) or each-axis workpiece coordinate system preset signals WPRST1 to
WPRST8<Gn358>.
Insert the workpiece coordinate system preset command before the NC command.
Number
Message
Contents
PS0569
ILLEGAL G28 AFTER PMC AXIS
G28 after PMC axis control should be incremental and commanded with no intermediate point
(0 stroke).
Number
Message
Contents
PS0570
FEEDRATE NOT FOUND IN P-TAPPING
The command F code for the cutting feedrate is 0.
If the value of the F command is much smaller than that of the S command, when a punch
tapping command is specified, this alarm is generated. This is because cutting is not possible
by the lead specified by the program.
Number
Message
Contents
PS0571
PROGRAM MISS AT P-TAPPING
1. In punch tapping, the position for a punch tapping command M code or an S command is
incorrect. Modify the program.
2. In punch tapping, the value for an I command is incorrect. Modify the program.
3. Punch tapping command with punch tapping G84.5,6,8 were commanded without
command of M code. Modify the program.
4. Rigid tapping command was issued while using punch tapping, or punch tapping
command was issued while using rigid tapping. Modify the program.
5. Canned cycle command for drilling was issued while using punch tapping, or punch
tapping command was issued while using canned cycle for drilling. Modify the program.
Number
Message
Contents
PS0572
ILLEGAL AXIS OPERATION
In punch tapping, an axis movement is specified between the punch tapping command M code
block and G84.5, 6, or 8 block. Modify the program.
Number
Message
Contents
PS0573
P-TAPPING MODE DI SIGNAL OFF
1. Although the punch tapping command M code is specified in the punch tapping, the
punch tapping mode DI signal (PNTAP) is not ON when executing the G84.5, 6, and 8
blocks. Check the PMC sequence program to find the reason why the DI signal is not
turned ON.
2. In the device with multi-spindle control, the spindle for punch tapping is not selected when
performing punch tapping.
Number
Message
Contents
PS0574
CAN NOT CHANGE PLANE (P-TAPPING)
Plane changeover was instructed during punch tapping. Modify the program.
Number
Message
Contents
PS0575
P-TAPPING DATA MISMATCH
P-TAPPING DATA MISMATCH
The specified distance was too short or too long in punch tapping.
Number
PS0580
345
Alarm list
B-64805EN/03
Message
Contents
P TYPE NOT ALLOWED(G53,G28,G30)
Program restart was performed in a block where P type program restart is not allowed.
Program restart cannot be performed after G53, G28, or G30 in a block without an absolute
command.
Specify a different block, or set bit 4 (MPE) of parameter No. 7333 to 1.
Number
Message
Contents
PS0581
SPINDLE INDEXING ILLEGAL COMMAND
G96.1 or G96.2 was specified during spindle indexing via a G96.2 command.
Number
Message
Contents
PS0601
ILLEGAL AXIS COMMAND FOR SERVO MOTOR SPINDLE
A move command has been given to the dedicated servo axis for spindle control by a servo
motor.
Modify the program.
Number
Message
Contents
PS1001
AXIS CONTROL MODE ILLEGAL
Axis control mode is illegal.
Number
Message
Contents
PS1013
ILLEGAL POS. OF PROGRAM NO.
Address O or N is specified in an illegal location (e.g. after a macro statement).
Number
Message
Contents
PS1014
ILLEGAL FORMAT OF PROGRAM NO.
Address O or N is not followed by a number.
Number
Message
Contents
PS1016
EOB NOT FOUND
EOB (End of Block) code is missing at the end of a program input in the MDI mode.
Number
Message
Contents
PS1059
COMMAND IN BUFFERING MODE
The manual intervention compensation request signal MIGET became "1" when an advanced
block was found during automatic operation.
To input the manual intervention compensation during automatic operation, a sequence for
manipulating the manual intervention compensation request signal MIGET is required in an M
code instruction without buffering.
Number
Message
Contents
PS1077
PROGRAM IN USE
An attempt was made in the foreground to execute a program being edited in the background.
The currently edited program cannot be executed, so end editing and restart program
execution.
Number
Message
Contents
PS1079
PROGRAM FILE NOT FOUND
The program of the specified file No. is not registered in an external device (external device
subprogram calling).
Number
Message
PS1080
DUPLICATE DEVICE SUB PROGRAM CALL
346
B-64805EN/03
Alarm list
Contents
Another external device subprogram call was made from a subprogram after the subprogram
called by the external device subprogram call.
Number
Message
Contents
PS1081
EXT DEVICE SUB PROGRAM CALL MODE ERROR
The external device subprogram call is not possible in this mode.
An M198 or M99 command was executed during schedule operation. Alternatively, the
execution of an M198 command was attempted during DNC operation. Modify the
program.
The execution of an M99 command was attempted by an interrupt macro during pocket
machining in a multiple repetitive cycle.
Number
Message
Contents
PS1090
PROGRAM FORMAT ERROR
A lowercase alphabetic character is found in other than an NC program statement comment
section, program name, or folder name.
Number
Message
Contents
PS1091
DUPLICATE SUB-CALL WORD
More than one subprogram call command was specified in the same block.
Number
Message
Contents
PS1092
DUPLICATE MACRO-CALL WORD
More than one macro call command was specified in the same block.
Number
Message
Contents
PS1093
DUPLICATE NC-WORD & M99
An address other than O, N, P or L was specified in the same block as M99 during the macro
modal call state.
Number
Message
Contents
PS1095
TOO MANY TYPE-2 ARGUMENT
More than ten sets of I, J and K arguments were specified in the type-II arguments (A, B, C, I,
J, K, I, J, K, ...) for custom macros.
Number
Message
Contents
PS1096
ILLEGAL VARIABLE NAME
An illegal variable name was specified.
A code that cannot be commanded as a variable name was commanded. The command of
[#_OFSxx] does not match the functional configuration of the tool offset memory.
Number
Message
Contents
PS1097
TOO LONG VARIABLE NAME
The specified variable name is too long.
Number
Message
Contents
PS1098
NO VARIABLE NAME
The specified variable name cannot be used as it is not registered.
Number
Message
Contents
PS1099
ILLLEGAL SUFFIX [ ]
A suffix was not specified to a variable name that required a suffix enclosed by [ ].
A suffix was specified to a variable name that did not require a suffix enclosed by [ ].
The value enclosed by the specified [ ] was out of range.
347
Alarm list
B-64805EN/03
Number
Message
Contents
PS1100
CANCEL WITHOUT MODAL CALL
Call mode cancel (G67) was specified even though macro continuous-state call mode (G66)
was not in effect.
Number
Message
Contents
PS1101
ILLEGAL CNC STATEMENT IRT.
An interrupt was made in a state where a custom macro interrupt containing a move instruction
could not be executed.
Number
Message
Contents
PS1115
READ PROTECTED VARIABLE
An attempt was made in a custom macro to use on the right side of an expression a variable
that can only be used on the left side of an expression.
Number
Message
Contents
PS1120
ILLEGAL ARGUMENT FORMAT
The specified argument in the argument function (ATAN, POW) is in error.
Number
Message
Contents
PS1124
MISSING DO STATEMENT
The DO instruction corresponding to the END instruction was missing in a custom macro.
Number
Message
Contents
PS1128
SEQUENCE NUMBER OUT OF RANGE
The sequence number of the jump destination in a GOTO instruction of custom macro
statement is out of the valid range (1 to 99999999).
Number
Message
Contents
PS1129
MISSING IF STATEMENT
There is no IF statement corresponding to ELSE and/or ENDIF.
Number
Message
Contents
PS1130
TOO MANY IF STATEMENT NESTING
The maximum IF statement nesting level (10 folds nested) was exceeded in the custom macro.
Number
Message
Contents
PS1131
MISSING OPEN BRACKET
The number of left brackets ([) is less than the number of right brackets (]) in a custom macro
statement.
Number
Message
Contents
PS1132
MISSING CLOSE BRACKET
The number of right brackets (]) is less than the number of left brackets ([) in a custom macro
statement.
Number
Message
Contents
PS1133
MISSING '='
An equal sign (=) is missing in the arithmetic calculation instruction in a custom macro
statement.
348
B-64805EN/03
Alarm list
Number
Message
Contents
PS1135
SPECIFIED LABEL IS NOT FOUND
The label specified for LGOTO [Label] in the custom macro was not found in the program.
Number
Message
Contents
PS1137
IF STATEMENT FORMAT ERROR
The format used in the IF statement in the custom macro is invalid.
Number
Message
Contents
PS1138
WHILE STATEMENT FORMAT ERROR
The format used in the WHILE statement in the custom macro is invalid.
Number
Message
Contents
PS1139
SETVN STATEMENT FORMAT ERROR
The format used in the SETVN statement in the custom macro is invalid.
Number
Message
Contents
PS1140
TOO MANY VARIABLE NAMES
The number of variable names specified in a SETVN or DEF statement exceeds the limit.
Number
Message
Contents
PS1141
ILLEGAL CHARACTER IN VAR. NAME
The SETVN statement in a custom macro contacts a character that cannot be used in a
variable name.
Number
Message
Contents
PS1142
TOO LONG V-NAME (SETVN)
The variable name used in a SETVN statement in a custom macro exceeds 8 characters.
Number
Message
Contents
PS1143
BPRNT/DPRNT STATEMENT FORMAT ERROR
The format used in the BPRINT statement or DPRINT statement is invalid.
Number
Message
Contents
PS1144
G10 FORMAT ERROR
The G10 L No. contains no relevant data input or corresponding option.
Data setting address P or R is not specified.
An address not relating to the data setting is specified. Which address to specify varies
according to the L No. The sign, decimal point or range of the specified address are in
error.
Number
Message
Contents
PS1145
G10.1 TIME OUT
The response to a G10.1 instruction was not received from the PMC within the specified time
limit.
Number
Message
Contents
PS1146
G10.1 FORMAT ERROR
The G10.1 instruction format is in error.
Number
Message
PS1147
DUPLICATE VARIABLE NAME
349
Alarm list
B-64805EN/03
Contents
The same name was specified in a SETVN or DEF statement for different variables.
Number
Message
Contents
PS1148
SWITCH STATEMENT ERROR
A SWITCH statement in the custom macro is erroneous. Possible causes are:
Improper format.
Not in the form of SWITCH[<Formula>].
EOB, CASE, or DEFAULT is not specified after SWITCH[<Formula>].
The value from evaluating <Formula> is outside the range of -2147483648 to 2147483647
(<Empty> is an out-of-range value).
Number
Message
Contents
PS1149
CASE STATEMENT ERROR
A CASE statement in the custom macro is erroneous. Possible causes are:
A CASE statement was specified while a SWITCH statement was not executed.
Improper format.
Not in the form of CASE[<Formula>].
GOTO is not specified after CASE[<Formula>]. However, if the value saved in the
SWITCH statement and <Formula> do not match, the alarm will not be generated.
The value from evaluating <Formula> is outside the range of -2147483648 to 2147483647
(<Empty> is an out-of-range value).
Number
Message
Contents
PS1150
DEFAULT STATEMENT ERROR
A DEFAULT statement in the custom macro is erroneous. Possible causes are:
A DEFAULT statements was specified while a SWITCH statement was not executed.
Improper format.
Not in the form of DEFAULT [ ].
EOB or GOTO is not specified after DEFAULT [ ].
Number
Message
Contents
PS1151
LABEL FORMAT ERROR
The format of LBL [Label] is erroneous.
Number
Message
Contents
PS1152
G31.9/G31.8 FORMAT ERROR
The format of the G31.9 (continuous high-speed skip function) or G31.8 (EGB skip function for
EGB axis/skip function for flexible synchronization control) block is erroneous in the following
cases:
The axis address was not specified in the G31.9 or G31.8 block.
Multiple axis addresses were specified in the G31.9 or G31.8 block.
P was not specified in the G31.9 or G31.8 block.
In the G31.8 block, an axis except slave axis was commanded in flexible synchronous
control mode.
The Q command in the G31.8 block was out of range in flexible synchronous mode.
Number
Message
Contents
PS1153
CANNOT USE G31.9
G31.9 cannot be specified in this modal state. This alarm is also generated when G31.9 is
specified when a group 07 G code (e.g. tool radius compensation) is not canceled.
Number
Message
Contents
PS1155
CMPPRG FORMAT ERROR
One of the CMPAPRG, CMPBPRG, CMPIPRG, CMPMPMPRG command format is invalid.
Please correct the program.
350
B-64805EN/03
Alarm list
Number
Message
Contents
PS1156
MACRO PROGRAM ERROR
The macro program is not specified correctly. Either of the following program corrections are
required.
- Tool diameter and tool nose radius compensation
- AI contour control II+
- Smooth tolerance + control
- Smooth interpolation
- Nano smoothing
- Smooth TCP and high-speed smooth TCP
- Continuous rapid traverse
(1) Specify it outside the mode
(2) Insert a non-buffering command
- NURBUS interpolation
- 3-dimensional circular interpolation
- Optional chamfering/corner R
- Direct drawing dimension programming
- Multiple repetitive cycle (G70 to G73)
(1) Specify it outside the mode
Number
Message
Contents
PS1161
DEF STATEMENT FORMAT ERROR
The format used in the DEF statement in a custom macro is in error.
Number
Message
Contents
PS1162
VAR NO. OF ARRAY IS OUT OF RANGE
The variable number specified for an array variable is out of range. The array variable number
needs to be between #0 to #4294967294. In case of a local variable, the variable number
needs to be in the range of #1 to #33.
Number
Message
Contents
PS1163
VARIABLE NO. OVERLAPPED
In a SETVN or DEF statement, a variable name was specified for a variable number that
already has a name.
Number
Message
Contents
PS1164
VAR SET BY THE SETVN STATEMENT
The variable name and number set in a SETVN statement cannot be changed with a DEF
statement.
Number
Message
Contents
PS1165
VAR SET BY THE DEF STATEMENT
The variable name and number set in a DEF statement cannot be changed with a SETVN
statement.
Number
Message
Contents
PS1166
1ST SUBSCRIPT IS OUT OF RANGE
The value specified for the first subscript of the array variable is out of range.
Number
Message
Contents
PS1167
2ND SUBSCRIPT IS OUT OF RANGE
The value specified for the second subscript of the array variable is out of range.
Number
Message
PS1168
3RD SUBSCRIPT IS OUT OF RANGE
351
Alarm list
B-64805EN/03
Contents
The value specified for the third subscript of the array variable is out of range.
Number
Message
Contents
PS1169
ILLEGAL NUMBER OF SUBSCRIPTS
The number of subscripts specified for the array variable is erroneous. This alarm is also
generated if a subscript was set for a variable that is not an array variable or if a subscript was
not specified for an array variable.
Number
Message
Contents
PS1171
ILLEGAL DATA NUMBER
System variables #3963 to #3965 were read or written while the system variable #3962
setting value was illegal.
A value other than 0 to 65535 was set for system variable #3962.
Due to bit 5 (SRW) of parameter No. 6023, reading/writing of system variables #3962 to
#3965 is prohibited.
Number
Message
Contents
PS1172
SHIFT VALUE SETTING ERROR
An attempt was made to set a value outside the valid range (-999999999 to +999999999) for
system variables #118551 to #118600.
Number
Message
Contents
PS1173
POPEN FORMAT ERROR
Causes of the alarm are as follows.
The format is invalid
A non-existent device symbol is specified
The folder or file name exceeds the number of characters allowed
File name specified with RS-232C
When using a macro variable, variable name, array variable, <expression>, or
<conditional expression> in a folder or file name, an unusable variable number or variable
name was used, or the value was outside the valid range
Number
Message
Contents
PS1174
ILLEGAL PMC PATH
The setting value of system variable #3968 is illegal.
Number
Message
Contents
PS1175
READ-ONLY PMC ADDRESS
A write command was specified for a read-only PMC address in the custom macro
(reading/writing of PMC address R via G310 command or system variables #3963 to #3965).
Number
Message
Contents
PS1196
ILLEGAL DRILLING AXIS SELECTED
An illegal axis was specified for drilling in a canned cycle for drilling.
If the zero point of the drilling axis is not specified or parallel axes are specified in a block
containing a G code in a canned cycle, simultaneously specify the parallel axes for the drilling
axis.
Number
Message
Contents
PS1200
PULSCODER INVALID ZERO RETURN
The grid position could not be calculated during grid reference position return using the grid
system as the one-revolution signal was not received before leaving the deceleration dog.
This alarm is also generated when the tool does not reach a feedrate that exceeds the servo
error amount preset to parameter No. 1841 before the deceleration limit switch is left
(deceleration signal *DEC returns to "1").
352
B-64805EN/03
Alarm list
Number
Message
Contents
PS1202
NO F COMMAND AT G93
F codes in the inverse time feed mode (G93) are not handled as modal, and must be specified
for each block.
Number
Message
Contents
PS1223
ILLEGAL SPINDLE SELECT
An attempt was made to execute an instruction that uses the spindle although the spindle
to be controlled has not been set correctly.
Interpolation type rigid tapping was specified in a path in which the Cs contouring control
function is not enabled.
Number
Message
Contents
PS1298
ILLEGAL INCH/METRIC CONVERSION
An error occurred during inch/metric switching.
Number
Message
Contents
PS1300
ILLEGAL ADDRESS
1. When a parameter is entered using an external equipment or G10, an axis number
address is commanded for parameters that are not in axis form.
2. L1 is incorrect when pitch error compensation data is entered using an external device or
G10.
3. When multi-point compensation data is input using an external equipment, addresses
other than N and P are commanded.
Number
Message
Contents
PS1301
MISSING ADDRESS
1. When a parameter is entered using an external equipment or G10, an axis number
address is not commanded for parameters that are in axis form.
2. There is no data number address N, setting data address P, or R command when pitch
error compensation data is input using an external equipment or G10.
3. When multi-point compensation is input using an external equipment, a value without an
address is commanded.
Number
Message
Contents
PS1302
ILLEGAL DATA NUMBER
1. When entering a parameter using an external equipment or G10, the number of the
entered parameter is incorrect.
2. Compensation point number N is incorrect when entering pitch error compensation data
using an external equipment or G10.
3. When multi-point compensation is entered using an external equipment, the
compensation point number N is incorrect.
4. An invalid address R value is specified in a pattern program for each machining purpose
on the high-speed high-precision setting screen.
This alarm also occurs if the value of the other word is incorrect.
Number
Message
Contents
PS1303
ILLEGAL AXIS NUMBER
An axis No. address exceeding the maximum number of controlled axes was found while
loading parameters from a tape or by entry of the G10 parameter.
Number
Message
Contents
PS1304
TOO MANY DIGIT
Data with too many digits was found while loading parameters or pitch error compensation data
from a tape.
353
Alarm list
B-64805EN/03
Number
Message
Contents
PS1305
DATA OUT OF RANGE
Data is out of range when parameters, pitch error compensation data, or multi-point
compensation data is entered using an external equipment.
When data is entered using G10, the value of the respective data setting address for the
number of L is out of range.
This alarm occurs when CNC programming words contain out-of-range values.
Number
Message
Contents
PS1306
MISSING AXIS NUMBER
A parameter which requires an axis to be specified was found without an axis No. (address A)
while loading parameters from a tape.
Number
Message
Contents
PS1307
ILLEGAL USE OF MINUS SIGN
The sign is commanded for addresses where the sign cannot be used.
There is an error in the use of the sign when entering parameter or pitch error compensation
data using an external equipment or G10.
When multi-point compensation is entered using an external equipment, there is an error in the
use of the sign.
Number
Message
Contents
PS1308
MISSING DATA
When parameters, pitch error compensation data, or multi-point compensation is entered using
an external equipment, the value is not commanded following the address.
Number
Message
Contents
PS1332
DATA WRITE LOCK ERROR
Parameters, pitch error compensation data, and workpiece coordinate system data could not
be registered from external.
Number
Message
Contents
PS1333
DATA WRITE ERROR
Could not write data while loading data from tape.
Number
Message
Contents
PS1370
PARAMETER SETTING ERROR (DM3H-1)
Out-of-range data was set during setting of the three-dimensional handle feed parameter.
Number
Message
Contents
PS1371
PARAMETER SETTING ERROR (DM3H-2)
An illegal axis of rotation was set during setting of the three-dimensional handle feed
parameter.
Number
Message
Contents
PS1372
PARAMETAR SETTING ERROR (DM3H-3)
An illegal master axis was set during setting of the three-dimensional handle feed parameter.
Number
Message
Contents
PS1470
G40.1-G42.1 PARAMETER MISS
A parameter setting related to normal direction control is illegal. The axis number of a normal
direction control axis is set in parameter No. 5480, but that axis number is in the range of the
number of controlled axes. The axis set as a normal direction control axis is not set as a
rotation axis (bit 0 (ROTx) of parameter No. 1006 = 1 and No.1022=0).
354
B-64805EN/03
Alarm list
Number
Message
Contents
PS1471
ILLEGAL COMMAND IN G40.1-G42.1
A G code which cannot be specified in the normal direction control mode was specified.
Number
Message
Contents
PS1508
DUPLICATE M-CODE(INDEX TABLE REVERSING)
A function for which the same code as this M code is set exists (index table indexing).
Number
Message
Contents
PS1509
DUPLICATE M-CODE (SPOS AXIS ORIENTATION)
A function for which the same code as this M code is set exists (spindle positioning orientation).
Number
Message
Contents
PS1510
DUPLICATE M-CODE (SPOS AXIS POSITIONING)
A function for which the same code as this M code is set exists (spindle positioning).
Number
Message
Contents
PS1511
DUPLICATE M-CODE(SPOS AXIS RELEASE)
A function for which the same code as this M code is set exists (spindle positioning mode
cancel).
Number
Message
Contents
PS1537
ADDRESS F UNDERFLOW (OVERRIDE)
The speed obtained by applying override to the F instruction is too slow.
Number
Message
Contents
PS1538
ADDRESS F OVERFLOW(OVERRIDE)
The speed obtained by applying override to the F instruction is too fast.
Number
Message
Contents
PS1543
ILLEGAL GEAR SETTING
The gear ratio between the spindle and position coder, or the set position coder number of
pulses is illegal in the spindle positioning function.
Number
Message
Contents
PS1561
ILLEGAL INDEXING ANGLE
The specified angle of rotation is not an integer multiple of the minimum indexing angle.
Number
Message
Contents
PS1564
INDEX TABLE AXIS - OTHER AXIS SAME TIME
The index table indexing axis and another axis have been specified in the same block.
Number
Message
Contents
PS1567
INDEX TABLE AXIS DUPLICATE AXIS COMMAND
Index table indexing was specified during axis movement or on an axis for which the index
table indexing sequence was not completed.
Number
Message
Contents
PS1580
ENCODE ALARM (PSWD&KEY)
When an attempt was made to read a program, the specified password did not match the
password on the tape and the password on tape was not equal to "0".
355
Alarm list
B-64805EN/03
When an attempt was made to punch an encrypted tape, the password was not in the range 1
to 99999999. The password parameter is No. 3220.
Number
Message
Contents
PS1581
ENCODE ALARM (PARAMETER)
When an attempt was made to punch an encrypted tape, the punch code parameter was set to
EIA. Set parameter ISO (No.0000#1) to 1.
An incorrect instruction was specified for program encryption or protection. This alarm is
generated if an attempt is made to perform part program editing, deletion, or range-specified
output in the protected range in the lock state. Or, a program outside the protected range is
specified in rage specification output in the unlock state.
The protected range is defined from the program No. preset by parameter No. 3222 up to the
program No. preset to parameter No. 3223. When both parameters are set to "0", the protected
range becomes O9000 to O9999.
Number
Message
Contents
PS1590
TH ERROR
A TH error was detected during reading from an input device. The read code that caused the
TH error and how many statements it is from the block can be verified in the diagnostics
screen.
Number
Message
Contents
PS1591
TV ERROR
An error was detected during the single-block TV error. The TV check can be suppressed by
setting bit 0 (TVC) of parameter No. 0000 to "0".
Number
Message
Contents
PS1593
EGB PARAMETER SETTING ERROR
Error in setting a parameter related to the EGB
The setting of SYN, bit 0 of parameter No. 2011, is not correct.
The slave axis specified with G81 is not set as a rotation axis (bit 0 (ROT) of parameter
No. 1006).
Number of pulses per rotation (Parameter (No. 7772 or No. 7773) or (No. 7782 or 7783))
is not set.
For a hobbing-machine-compatible command, parameter No. 7710 is not specified.
The slave axis commanded by the G81 is the slave axis of simple spindle EGB.
No signal-based servo EGB synchronization ratio (parameters Nos. 7784 and 7785) has
been set.
Number
Message
Contents
PS1594
EGB FORMAT ERROR
Error in the format of the block of an EGB command
T (number of teeth) is not specified in the G81 block.
In the G81 block, the data specified for one of T, L, P, and Q is out of its valid range.
In the G81 block, only one of P and Q is specified.
In the G81.5 block, there is no command for the master or slave axis.
In the G81.5 block, data out of the specified range is specified for the master or slave axis.
Number
Message
Contents
PS1595
ILL-COMMAND IN EGB MODE
An illegal command was specified during synchronization via EGB.
Slave axis command using G27, G28, G29, G30, G30.1, G33, G53, etc.
Inch/metric conversion command using G20, G21, etc.
Synchronization start command using G81 or G81.5 when bit 3 (ECN) of parameter No.
7731 is 0
For the slave axis of the spindle EGB, the Cs contouring control mode is not selected.
Inch/metric conversion command during helical gear compensation (settings screen, G10,
system variable, PMC window).
356
B-64805EN/03
Alarm list
Number
Message
Contents
PS1596
EGB OVERFLOW
An overflow occurred in the calculation of the synchronization coefficient.
Number
Message
Contents
PS1597
EGB AUTO PHASE FORMAT ERROR
Format error in the G80 or G81 block in EGB automatic phase synchronization
R is outside the permissible range.
In spindle EGB, before the G81R2 command, reference position return is not executed on
the master spindle.
Number
Message
Contents
PS1598
EGB AUTO PHASE PARAMETER SETTING ERROR
Error in the setting of a parameter related to EGB automatic phase synchronization
The acceleration/deceleration parameter is not correct.
The automatic phase synchronization parameter is not correct.
Number
Message
Contents
PS1720
ECCENTRIC TURNING FORMAT ERROR
The format of eccentric turning is incorrect.
Causes of the alarm are as follows.
An axis other than the selected plane is specified.
Addresses R, L, or S are not specified.
Number
Message
Contents
PS1721
ECCNTRC TRNNG COMMAND ILLEGAL
Eccentric turning is not specified correctly.
Causes of the alarm are as follows.
The modal G code is illegal.
The auxiliary function is specified.
A one-shot G code is specified.
Number
Message
Contents
PS1722
ECCNTRC TRNNG PARAMETER ERROR
The setting of the eccentric turning parameter is incorrect.
Number
Message
Contents
PS1723
ECCENTRIC TURNING ILLEGAL SHAPE
The command format of eccentric turning is incorrect.
Number
Message
Contents
PS1740
ORBIT CUT ILLEGAL SETTING
Parameter No. 1022 is not set correctly.
0 is set for all axes in parameter No. 12723.
Orbit cutting mode is turned on with orbit cut axes 1 to 3 and orbit cut spindle working as
slave axes for flexible synchronization control.
A function that cannot be used together with orbit cutting is being executing.
Flexible synchronization between paths
Superimposed control
Angular axis control
Parallel axis control
Synchronous composite control
Mirror image
Controlled axis removal
Servo off
357
Alarm list
B-64805EN/03
PMC axis control
Number
Message
Contents
PS1742
ORBIT CUT ILLEGAL COMMAND
The Q value specified with G8.6 is incorrect.
G8.6 was not specified in a single block.
G8.6Q1/Q2 command was specified while orbit cutting mode was ON.
G8.6Q0 command was specified while orbit cutting mode was OFF.
G8.6Q1/Q2 command was specified while SV rotation control mode was ON for the
spindle control by the servo motor.
Bit 0 of parameter No. 11000 of the orbit cutting spindle is set to 1.
Number
Message
Contents
PS1743
ORBIT CUT ILLEGAL AXIS COMMAND
A travel command was performed for the second orbit cutting axis during orbit cutting mode.
Number
Message
Contents
PS1744
ORBIT CUT ILLEGAL SP COMMAND
A P command with an illegal value was specified with G8.6 command.
A spindle of a different path was selected with G8.6 command.
When the orbit cutting spindle is the spindle axis, the orbit cutting spindle is not in the Cs
contouring control mode.
The parameter for the orbit cutting spindle control is not set correctly.
Number
Message
Contents
PS1745
IMPROPER G-CODE(ORBIT CUT)
An illegal G code was specified in the orbit cutting mode.
Number
Message
Contents
PS1805
ILLEGAL COMMAND
[I/O Device]
An attempt was made to specify an illegal command during I/O processing on an I/O device.
[G30 reference position return]
The P address numbers for instructing No. 2 to No. 4 reference position return are each out of
the range 2 to 4.
[Single Rotation Dwell]
The specified spindle rotation is "0" when single rotation dwell is specified.
Number
Message
Contents
PS1806
DEVICE TYPE MISS MATCH
An operation not possible on the I/O device that is currently selected in the setting was
specified.
This alarm is also generated when file rewind is instructed even though the I/O device is not a
FANUC Cassette.
Number
Message
Contents
PS1807
PARAMETER SETTING ERROR
An I/O interface option that has not yet been added on was specified.
The external I/O device and baud rate, stop bit and protocol selection settings are erroneous.
Number
Message
Contents
PS1808
DEVICE DOUBLE OPENED
An attempt was made to open a device that is being accessed.
Number
PS1809
358
B-64805EN/03
Alarm list
Message
Contents
ILLEGAL COMMAND IN G41/G42
Specified direction tool length compensation parameters are incorrect.
A move instruction for an axis of rotation was specified in the specified direction tool length
compensation mode.
Number
Message
Contents
PS1820
TOO MANY DI ON
Each-axis workpiece coordinate system preset signals were turned on in the state in
which all axes on the path including the axis on which to perform preset with the each axis
workpiece coordinate system were not stopped or in which a command was in execution.
When an M code for performing preset with an each-axis workpiece coordinate system
preset signal was specified, each axis workpiece coordinate system preset signals were
not turned on.
The auxiliary function lock is enabled.
When the M, S, T, and B codes are not output in the high-speed program check mode (bit
6 (PGS) of parameter No. 3001 was set to 0), an M code for turning each-axis workpiece
coordinate system preset signals on in the high-speed program check mode was
specified.
Number
Message
Contents
PS1822
ILLEGAL G31 COMMAND
Number
Message
Contents
PS1889
ILLEGAL COMMAND IN G54.3
An illegal command was issued in G54.3 block.
An attempt was made to command G54.3 in a mode in which it cannot be accepted.
The command was not issued in a single block.
Number
Message
Contents
PS1892
ILLEGAL PARAMETER IN G43.3
A parameter related to nutating rotary head tool length compensation is incorrect.
Number
Message
Contents
PS1893
ILLEGAL PARAMETER IN G44.9
A parameter related to spindle unit compensation is incorrect.
Number
Message
Contents
PS1898
ILLEGAL PARAMETER IN G54.2
An illegal parameter (Nos. 7580 to 7588) was specified for fixture offset.
Number
Message
Contents
PS1912
V-DEVICE DRIVER ERROR (OPEN)
An error occurred during device driver control.
Number
Message
Contents
PS2060
ILLEGAL PARAMETER IN G43.4/G43.5
The parameter for the pivot tool length compensation is incorrect.
Number
Message
Contents
PS2061
ILLEGAL COMMAND IN G43.4/G43.5
An illegal command was specified in tool center point control.
A rotation axis command was specified in tool center point control (type 2) mode.
With a table rotary type or mixed-type machine, a I, J, or K command was specified in the
tool center point control (type 2) (G43.5) block.
359
Alarm list
B-64805EN/03
A command that does not move the tool center point (only a rotation axis is moved) was
specified for the workpiece in the G02 mode.
G43.4 or G43.5 was specified in the tool center point control mode.
When the workpiece coordinate system is set as the programming coordinate system (bit
5 (WKP) of parameter No. 19696 is 1), G02 or G03 was specified while the rotation axis
was not perpendicular to the plane.
Number
Message
Contents
PS2070
G02.1/G03.1 FORMAT ERROR
The format is invalid.
The specified arc exceeds the interpolation enable range.
Number
Message
Contents
PS2085
G04.1 FORMAT ERROR
The G04.1 block was not independently specified.
Number
Message
Contents
PS2095
ILLEGAL REGISTER OF PEAX PROGRAM
The peripheral axis control program cannot be registered because of the following factors.
G100 was not commanded after the G101 (or G102, G103) was commanded.
There is not Q command in the same block as the registration start command (G101,
G102, and G103) of the peripheral axis control program (only when an axis of a certain a
path is allocated as the peripheral axis of multiple peripheral axis controls).
Number
Message
Contents
PS4010
ILLEGAL REAL VALUE OF OBUF :
The real value for a output buffer is in error.
Number
Message
Contents
PS4531
U/V MACRO FORMAT ERROR
An attempt was made to store a macro while storing another macro using a U or V macro.
A V macro was specified although the processing to store a macro was not in progress.
A U macro number and V macro number do not correspond with each other.
Number
Message
Contents
PS4532
INPROPER U/V MACRO NUMBER
The number of an inhibited macro number (other than 01 to 99) was specified in a U or V
macro command.
Number
Message
Contents
PS4533
U/V MACRO MEMORY OVERFLOW
An attempt was made to store too many macros with a U or V macro command.
Number
Message
Contents
PS4534
W MACRO NUMBER NOT FOUND
Macro number W specified in a U or V macro command is not stored.
Number
Message
Contents
PS4536
NO W,Q COMMAND IN MULTI-PIECE
W or Q was not specified in the command for taking multiple workpieces (G73, G74).
Number
Message
PS4537
ILLEGAL Q VALUE IN MULTI-PIECE
360
B-64805EN/03
Alarm list
Contents
In the command for taking multiple workpieces (G73, G74), Q is set to a value beyond the
range from 1 to 4.
Number
Message
Contents
PS4538
W NO. NOT FOUND IN MULTI-PIECE
Macro number W specified in the multi-piece machining command (G73, G74) is not stored.
Number
Message
Contents
PS4539
MULTI-PIECE SETTING IS ZERO
The command for multi-piece machining (G73, G74) was specified although zero is set for
multi-piece machining (parameter No. 16206 or signals MLP1 and MLP2 <Gn231.0 and
Gn231.1>).
Number
Message
Contents
PS4540
MULTI-PIECE COMMAND WITHIN MACRO
The multi-piece machining command (G73, G74) was specified when a U or V macro was
being stored.
Number
Message
Contents
PS4542
MULTI-PIECE COMMAND ERROR
Although G98 P0 was specified, the G73 command was issued.
Although G98 K0 was specified, the G74 command was issued.
Number
Message
Contents
PS4543
MULTI-PIECE Q COMMAND ERROR
Although G98 P0 was specified, the Q value for the G74 command was not 1 or 3.
Although G98 K0 was specified, the Q value for the G73 command was not 1 or 2.
Number
Message
Contents
PS4544
MULTI-PIECE P/R COMMAND ERROR
In the command for restarting multi-piece machining, the resume position (P) is set to a value
beyond the range from "1 to total number of workpieces to be machined".
Number
Message
Contents
PS4600
T,C COMMAND IN INTERPOLATION
In the linear interpolation (G01) mode or circular interpolation (G02, G03) mode, a T command
or C-axis command was specified.
Number
Message
Contents
PS4630
ILLEGAL COMMAND IN LASER MODE
In the laser mode, a nibbling command or pattern command was specified.
Number
Message
Contents
PS4872
AUTO SETTING COMMAND ERROR
M code, S code or T code is specified with safety zone auto setting command (G32).
An automatic setting command was specified is specified in the nibbling mode,
An automatic setting command was specified in the cutter compensation, coordinate
system rotation or scaling mode.
Number
Message
Contents
PS5006
TOO MANY WORD IN ONE BLOCK
The number of words in a block exceeds the maximum. The maximum is 26 words. However,
this figure varies according to CNC options.
Divide the instruction word into two blocks.
361
Alarm list
B-64805EN/03
Number
Message
Contents
PS5007
TOO LARGE DISTANCE
Due to compensation, point of intersection calculation, or interpolation, a movement
distance has exceeded the max. programmable dimension. Check the programmed
coordinates or compensation amounts.
When incremental commands are given to a rotary axis with rollover function disabled and
parameter (No.11270) set to a value other than 0 for rotary axis A type, the command
should be given so that the travel of one block does not exceed parameter (No.11270).
Number
Message
Contents
PS5009
PARAMETER ZERO(DRY RUN)
The dry run rate parameter No. 1410 or the parameter for the maximum cutting feedrate for
each axis is 0.
The parameter for the maximum cutting feedrate for each axis is No. 1432 if
acceleration/deceleration before look-ahead interpolation is enabled and No. 1430 otherwise.
Functions that cause acceleration/deceleration before look-ahead interpolation include AI
contour control, tool center point control, and workpiece setting error compensation.
Number
Message
Contents
PS5010
END OF RECORD
The EOR (End of Record) code is specified in the middle of a block.
This alarm is also generated when the percentage at the end of the NC program is read.
Number
Message
Contents
PS5011
PARAMETER ZERO (CUT MAX)
The setting of the parameter for the maximum cutting feedrate is 0. The parameter is No. 1432
if acceleration/deceleration before look-ahead interpolation is enabled and No. 1430 otherwise.
Functions that cause acceleration/deceleration before look-ahead interpolation include AI
contour control, tool center point control, and workpiece setting error compensation.
Number
Message
Contents
PS5016
ILLEGAL COMBINATION OF M CODES
M codes which belonged to the same group were specified in a block. Alternatively, an M code
which must be specified without other M codes in the block was specified in a block with other
M codes.
Number
Message
Contents
PS5018
POLYGON SPINDLE SPEED ERROR
In G51.2 mode, the speed of the spindle or polygon synchronous axis either exceeds the clamp
value or is too small. The specified rotation speed ratio thus cannot be maintained.
For polygon turning with two spindles, more information as to why this alarm occurred is
indicated in diagnosis data No. 0471.
Number
Message
Contents
PS5030
ILLEGAL COMMAND (G100)
The end command (G100) was specified (peripheral axis control) before the registration start
command (G101, G102, or G103) was specified.
Number
Message
Contents
PS5031
ILLEGAL COMMAND (G101,G102,G103)
While a registration start command was being executed, another registration start command
(G101, G102, or G103) was specified (peripheral axis control).
Number
Message
PS5032
NEW PRG REGISTERED IN PEAX MOVE
362
B-64805EN/03
Alarm list
Contents
While the peripheral axis control is being executed, an attempt to register another move
command was made.
Number
Message
Contents
PS5033
NO PROG SPACE IN MEMORY PEAX
The program of the peripheral axis control was not registered because of insufficient program
memory.
Number
Message
Contents
PS5034
PLURAL COMMAND IN G110
Multiple motions were specified in G110 (peripheral axis control).
Number
Message
Contents
PS5038
TOO MANY START M-CODE COMMAND
More than six M codes to start the peripheral axis control were specified.
Number
Message
Contents
PS5039
START UNREGISTERED PEAX PROG
An attempt was made to execute a program for the peripheral axis control which had not been
registered.
Number
Message
Contents
PS5040
CAN NOT COMMANDED PEAX MOVE
The machine could not start the peripheral axis control.
The parameters Nos. 11884 to 11891 were incorrectly specified. Therefore, peripheral
axis control cannot be executed.
The data, which is required to be deleted, was not deleted after setting the parameters
Nos.11884 to 11891.
The system type of the path which operates peripheral axis control is different from the
parameter No.0983 of the path which is set by parameters No.3040 to No.3042 when
peripheral axis control is operated by the path which is not set by the parameters No.3040
to No.3042.
Command mode of the path which uses peripheral axis control has been switched by
lathe/machining center G-code system switching function.
Peripheral axis control cannot be started when the feed hold signal *SP<Gn008#5> for the
peripheral axis control is set to 0.
Number
Message
Contents
PS5043
TOO MANY G68 NESTING
3-dimensional coordinate conversion has been specified three or more times.
To perform another coordinate conversion, perform cancellation, then specify the coordinate
conversion.
Number
Message
Contents
PS5044
G68 FORMAT ERROR
The block specified with 3-dimensional coordinate conversion command exists the following
errors.
All of I, J, or K commands were not specified in the 3-dimensional coordinate conversion
command block (when the coordinate system rotation optional function is not available).
All of I, J, or K command were 0 in the block specified with 3-dimensional coordinate
conversion command.
No rotation angle R was not commanded in the block specified with 3-dimensional
coordinate conversion command.
Number
Message
PS5050
ILL-COMMAND IN G81.1 MODE
363
Alarm list
Contents
B-64805EN/03
During chopping/oscillation, a move command was issued for the chopping/oscillation
axis.
A chopping/oscillation command was issued for the Cs contouring control axis.
Machine lock was performed for the axis for which oscillation was being performed.
An oscillation command was issued for the slave axis for superimposed control.
Number
Message
Contents
PS5058
G35/G36 FORMAT ERROR
A command for switching the major axis has been specified for circular threading.
Alternatively, a command for setting the length of the major axis to 0 has been specified for
circular threading.
Number
Message
Contents
PS5065
DIFFERRENT AXIS UNIT
Axes having different increment systems have been specified in the same DI/DO group for
PMC axis control. Modify the setting of parameter No. 8010.
Number
Message
Contents
PS5068
FORMAT ERROR IN G31P90
A travel axis is not specified.
Two or more travel axes were specified.
Number
Message
Contents
PS5073
NO DECIMAL POINT
No decimal point has been specified for an address requiring a decimal point.
Number
Message
Contents
PS5074
ADDRESS DUPLICATION ERROR
The same address has been specified two or more times in a single block. Alternatively, two or
more G codes in the same group have been specified in a single block.
Number
Message
Contents
PS5085
SMOOTH IPL ERROR 1
A block for specifying smooth interpolation contains a syntax error.
Number
Message
Contents
PS5110
IMPROPER G-CODE(AICC MODE)
An unspecifiable G code was specified in the AI contour control mode.
Number
Message
Contents
PS5122
ILLEGAL COMMAND IN SPIRAL
A spiral interpolation or conical interpolation command has an error. Specifically, this error is
caused by one of the following:
L = 0 is specified.
Q = 0 is specified.
R, R, C is specified.
Zero is specified as height increment.
Zero is specified as height difference.
Three or more axes are specified as the height axes.
A height increment is specified when there are two height axes.
Q is specified when radius difference = 0.
Q < 0 is specified when radius difference > 0.
Q > 0 is specified when radius difference < 0.
A height increment is specified when no height axis is specified.
364
B-64805EN/03
Alarm list
Number
Message
Contents
PS5123
OVER TOLERANCE OF END POINT IN SPIRAL
The difference between a specified end point and the calculated end point exceeds the
allowable range (parameter 3471).
Number
Message
Contents
PS5124
CAN NOT COMMAND SPIRAL
A spiral interpolation or conical interpolation was specified in any of the following modes:
Scaling
Polar coordinate interpolation
In the tool radius - tool nose radius compensation mode, the center is set as the end point.
Number
Message
Contents
PS5130
NC AND SUPERIMPOSE AXIS CONFLICT
In the PMC superposition axis control, the NC command and The PMC axis control command
were conflicted. Correct the program or PMC sequence program.
Number
Message
Contents
PS5131
NC COMMAND IS NOT COMPATIBLE
The PMC axis control and 3-dimensional coordinate conversion or a polar coordinate
interpolation were specified simultaneously. Correct the program or PMC sequence program.
Number
Message
Contents
PS5132
CANNOT CHANGE SUPERIMPOSED AXIS
The superposition axis was selected for the axis for which the PMC superposition axis is being
controlled.
Number
Message
Contents
PS5195
NOT FOUND DIRECTION
Measurement is invalid in the tool compensation measurement value direct input B function.
[For 1-contact input]
The recorded pulse direction is not constant.
The machine is at a stop in the offset write mode.
The servo power is off.
Pulse directions are diverse.
The tool is moving along the two axes (X-axis and Z-axis).
[For the movement direction discrimination specification]
The recorded pulse direction is not constant.
The machine is at a stop in the offset write mode.
The servo power is off.
Pulse directions are diverse.
The tool is moving along the two axes (X-axis and Z-axis).
The direction indicated by the tool compensation write signal does not match the
movement direction of the axis.
Number
Message
Contents
PS5196
ILLEGAL AXIS OPERATION
During HPCC or during the execution of a 5-axis-related function, an unavailable function was
used.
Number
Message
Contents
PS5199
ILLEGAL FINE TORQUE SENSING PARAMETER
A parameter for fine torque sensing is incorrectly set.
The control axis number of the target axis is invalid.
365
Alarm list
B-64805EN/03
Number
Message
Contents
PS5211
ILLEGAL AXIS OPERATION
In servo spindle synchronization mode, a servo axis command was executed from the
CNC. Modify the program.
A travel command was specified from the CNC for the servo motor during
acceleration/deceleration in servo motor spindle synchronous control mode.
A travel command was specified from the CNC for the servo motor in servo motor spindle
synchronous control mode when the differential speed synchronization command signal
DFSYC and servo motor spindle switch signal SVSP are set to "1".
Number
Message
Contents
PS5219
CAN NOT RETURN
Manual intervention and return cannot be performed during execution of 3-dimensional
coordinate conversion, tilted working plane indexing command, tool center point control, or
workpiece setting error compensation.
Number
Message
Contents
PS5220
REFERENCE POINT ADJUSTMENT MODE
Parameter DATx (No.1819#2) = 1 is set to automatically set the reference point
position.Position the machine at the reference point in manual operation and perform a manual
reference position return.
Number
Message
Contents
PS5242
ILLEGAL AXIS NUMBER
A master axis number or a slave axis number was not set correctly when the flexible
synchronization control mode was turned from off to on during automatic operation.
Automatic phase matching is enabled, and the units of the master axis and slave axis are
different.
Automatic phase matching is enabled, and rotary axis settings for the master axis and
slave axis are invalid.
The error occurs in inter-path flexible synchronization control at either of the conditions
below (occurs when starting inter-path flexible synchronization control).
The axis number of the master or slave axis is incorrect.
The master and slave axis settings make a loop.
Number
Message
Contents
PS5243
DATA OUT OF RANGE
A gear ratio was not set correctly when the flexible synchronization control mode was
turned from off to on during automatic operation.
An overflow occurred in the calculation of the synchronization coefficient for the hob
command of flexible synchronization control.
Number
Message
Contents
PS5244
TOO MANY DI ON
When an attempt was made to change the flexible synchronization control status, the
select signal was not turned on or off after the execution of the M code.
Flexible synchronization control was turned ON/OFF without stopping the axis (except
when using automatic phase matching for flexible synchronization control).
Flexible synchronization control was turned off in any of the following function modes:
Tool center point control
Tilted working plane indexing
3-dimensional cutter compensation
Workpiece setting error compensation
In the program containing the hob command of flexible synchronization control (G81,
G81.4, G80, G80.4), program restart or quick program restart were executed, and the
synchronous mode was not switched successfully.
Number
Message
PS5245
OTHER AXIS ARE COMMANDED
366
B-64805EN/03
Contents
Alarm list
For a flexible synchronization control group for which a PMC axis or spindle control with
servo motor was a master axis, an attempt was made to turn on the synchronous mode
during time other than automatic operation.
An attempt was made to turn on a synchronization group for which a PMC axis or spindle
control with servo motor was a master axis or a synchronization group for the hob
command when there existed a flexible synchronization control group for which a normal
axis (not a PMC axis or spindle control with servo motor) was a master axis.
The master and slave axes as synchronous axes overlap the EGB dummy axis.
The master and slave axes as synchronous axes overlap the chopping axis.
The master and slave axes as synchronous axes overlap the axis related to angular axis
control.
The master and slave axes as synchronous axes overlap the axis related to composite
control.
The master and slave axes as synchronous axes overlap the axis related to
superimposed control.
The slave axis as a synchronous axis overlaps the axis related to synchronization control.
The reference position return mode is turned on (was turned on).
A servo alarm occurred in a path in inter-path flexible synchronization control.
An emergency stop was applied in another path in inter-path flexible synchronization
control.
When an attempt was made to execute flexible synchronization between different paths
during automatic operation, the inter-path flexible synchronous mode was not enabled.
When the overtravel alarm is issued for the slave axis:
Flexible synchronization control on/off during orbit cutting mode.
Number
Message
Contents
PS5253
T/M MODE CAN NOT BE SWITCHED
Although a command mode switching M code is specified, the mode cannot be switched.
When a command mode switching M code is specified, a modal G code is not canceled.
The same value is set in parameters Nos. 13020 and 13021.
The high-speed program check function is performing check operation.
Program restart function is performing search operation.
An interruption type custom macro is performing interrupt operation.
Number
Message
Contents
PS5255
G12.4/G13.4 FORMAT ERROR
The specified P, I, and K are incorrect or I is less than K.
Number
Message
Contents
PS5256
G12.4/G13.4 EXECUTION ERROR
In groove cutting by continuous circle motion mode, a command other than G01, G02,
G03, G04, G90, G91, and auxiliary functions is specified.
In a mode that cannot be used, the groove cutting by continuous circle motion command
is specified.
Number
Message
Contents
PS5257
G41/G42 NOT ALLOWED IN MDI MODE
Tool radius - tool nose radius compensation was specified in MDI mode (via the setting of bit 4
(MCR) of parameter No. 5008).
Number
Message
Contents
PS5305
ILLEGAL SPINDLE NUMBER
In a spindle select function by address P in multi-spindle control,
Address P is not specified.
Parameter No.3781 is not specified to the spindle to be selected.
An illegal G code which cannot be commanded with an S_ P_ ; command is specified.
A multi spindle cannot be used because the bit 1 (EMS) of parameter No. 3702 is 1.
The spindle amplifier number of each spindle is not set in parameter No. 3717.
A prohibited command for a spindle was issued (parameter No. 11090).
367
Alarm list
B-64805EN/03
An invalid value is set in parameter No. 11090.
Alarm
Message
Contents
PS5306
MODE CHANGE ERROR
Mode switch at start is not performed correctly.
When not in a reset state, one-touch macro was started during reset and emergency stop.
Number
Message
Contents
PS5312
ILLEGAL COMMAND IN G10 L75/76/77
One of formats in G10 L75, G10 L76, or G10 L77 to G11 commands is in error, or the
command value is out of data range. Modify the program.
Number
Message
Contents
PS5316
TOOL TYPE NUMBER NOT FOUND
A tool with the specified tool-type number could not be found.
Modify the program or register the tool.
Number
Message
Contents
PS5317
ALL TOOL LIFE IS OVER
The lives of all tools with the specified tool-type number have expired. Replace the tool.
Number
Message
Contents
PS5320
DIA./RAD. MODE CAN'T BE SWITCHED
In any of the following states, diameter/radius programming was switched.
When a buffered program is being executed
When a movement is being made on the axis
Diameter/radius setting switching function is specified to the axis for which bit 0 (TMDx) of
parameter No. 10730 is set to 1.
Number
Message
Contents
PS5324
REFERENCE RETURN INCOMPLETE
Manual reference position return cannot be performed during 3-dimensional coordinate
conversion, tilted working plane indexing, or workpiece setting error compensation.
Number
Message
Contents
PS5329
M98 AND NC COMMAND IN SAME BLOCK
A subprogram call which is not a single block was commanded during canned cycle mode.
Modify the program.
Number
Message
Contents
PS5330
G50.9 FORMAT ERROR
There is not coordinates value specification in G50.9 block.
There is not M code, B code command in the G50.9 block.
G50.9 is commanded in canned cycle mode.
3 blocks of G50.9 block are commanded consecutively.
Number
Message
Contents
PS5331
ILLEGAL COMMANDED POSITION
It didn't reach a commanded absolute coordinate value. The movement command or absolute
coordinates at G50.9 block are wrong.
Number
Message
PS5334
Cs CONTOUR CONTROL AXIS REF. RETURN INCOMPLETE
368
B-64805EN/03
Alarm list
Contents
Reference position return of the Cs contouring control axis has not been completed for linear
interpolation type positioning that includes the Cs contouring control axis. Perform return to
origin.
Number
Message
Contents
PS5346
RETURN TO REFERENCE POINT
Due to the following reason, coordinates of the Cs contouring control axis cannot be
established. Perform manual reference position return.
Cs-axis coordinate establishment was made for the Cs axis for which the Cs-axis
reference position status signal CSPENs was 0
Positional information was not sent from the spindle amplifier
The servo off state is entered during the start of Cs-axis coordinate establishment
The Cs axis is subjected to synchronization control or superimposed control
The emergency stop state is entered during coordinate establishment
An attempt was made to release composite control for the Cs axis being subjected to
coordinate establishment
An attempt was made to start synchronous, composite, or superimposed control for the
Cs axis being subjected to coordinate establishment
Number
Message
Contents
PS5355
S CODE IS NOT COMMANDED AT G96
Surface speed S is not specified in constant surface speed control (G96). Command S code at
G96 block.
Number
Message
Contents
PS5356
IMPROPER G-CODE
Illegal G code was commanded in the hypothetical axis command mode or in the real axis
command mode.
Number
Message
Contents
PS5357
ILLEGAL AXIS SELECT
The real axis is commanded in the hypothetical axis commanded mode. The hypothetical axis
is commanded in the real axis command mode.
Number
Message
Contents
PS5359
MODE CHANGE ERROR
This alarm is generated in the following cases.
Mode switching was executed without using non-buffering M code in automatic operation.
Mode was switched to the hypothetical axis command mode in case that any axis in the
hypothetical plane loses the reference position.
During the hypothetical axis command mode, any axis in the hypothetical plane loses the
reference position.
Mode switching was performed when bit 1 (LRP) of parameter No. 1401 (non-linear
interpolation positioning) is set to 0.
Mode switching was executed during the following mode.
Cutter radius compensation mode
Tool length compensation mode
Tool offset mode
Scaling mode
Programmable mirror image mode
Coordinate system rotation mode
Canned cycle mode
Mode switching was executed when real axis in the hypothetical plane is moving.
Number
Message
PS5360
TOOL INTERFERENCE CHECK ERROR
369
Alarm list
B-64805EN/03
Contents
This alarm is issued when interference with another tool is caused by a data modification
based on G10 data input or file input or when an attempt is made to modify the tool figure data
of a tool registered in the cartridge.
Number
Message
Contents
PS5361
ILLEGAL MAGAZINE DATA
Tools stored in the cartridge are interfering with each other. Reregister the tools in the
cartridge, or modify the tool management data or tool figure data. If this alarm is issued, no tool
interference check is made when tools are registered in the cartridge management table.
Moreover, empty pot search operation does not operate normally. If this alarm is issued, the
power must be turned off before operation is continued.
Number
Message
Contents
PS5362
CONVERT INCH/MM AT REF-POS.
When bit 1 (INAx) of parameter No. 14000 was set to 1, inch/metric conversion was
performed at a machine coordinate position other than 0. Perform an inch/metric
conversion after returning to a position where the machine coordinate is 0.
When bit 3 (IMRx) of parameter No. 14000 was set to 1 or when bit 2 (IRFx) of parameter
No. 14000 was set to 1, inch/metric conversion was performed at a position other than a
reference position (parameter No. 1240). Perform an inch/metric conversion after
returning to the reference position.
When bit 0 (NIM) of parameter No.11222 was set to 1, programmable parameter input or
inch/metric conversion for #3005 (setting data) was performed at a machine coordinate
position other than 0. Issue the command at a position where the machine coordinate is 0.
Number
Message
Contents
PS5365
CANNOT CHANGE OF PROGRAM CHECK MODE
Switching of high-speed program check input signal PGCK <Gn290.5> was performed during
execution of the program.
Number
Message
Contents
PS5374
FSC MODE MISMATCH IN RESTART
The current flexible synchronous mode differs from the flexible synchronous mode specified in
a programmed command in the program restart block.
Re-check the restarting block.
Number
Message
Contents
PS5375
FSC MODE CAN NOT CHANGED
The flexible synchronous mode was changed during the execution of program restart.
Re-check the restarting block.
Number
Message
Contents
PS5376
FSC SLAVE AXIS CAN NOT COMMANDED
In the flexible synchronous mode, a command was specified for the slave axis.
Number
Message
Contents
PS5377
INVALID COMMAND AFTER FSC OFF
After the flexible synchronous mode was canceled, an incremental command was specified
before an absolute command for the axis specified as the slave axis.
Number
Message
Contents
PS5379
WRITE PROTECTED TO SLAVE AXIS
It is not possible to directly set the parameters for the slave axis under axis synchronous
control.
Number
PS5381
370
B-64805EN/03
Alarm list
Message
Contents
INVALID COMMAND IN FSC MODE
An attempt was made to issue the following commands:
When the reference position for the master axis under flexible synchronization control has
not been established, G28 command for the master axis.
G27/G28/G29/G30/G30.1/G53 command for a slave axis.
Inch/metric switch command via G20, G21.
Inch/metric conversion command during helical gear compensation (settings screen, G10,
system variable, PMC window).
Number
Message
Contents
PS5384
RETRACT FOR RIGID CANNOT BE CMD.
In retraction for 3-dimensional rigid tapping by the G30 command, the program coordinate
system used when rigid tapping is stopped and that used for retraction for rigid tapping are
different.
This program coordinate system is a coordinate system for a program after conversion that is
determined by the rotation center, rotation direction, and rotation angle specified in the G68 or
G68.2 arguments. In short, since the G68 or G68.2 command argument differs between when
stopped and resumed, correct the program.
Number
Message
Contents
PS5391
CAN NOT USE G92
Workpiece coordinate system setting (G92, or G50 for the lathe system G-code system A)
cannot be specified.
After tool length compensation was changed by tool length compensation shift type, G92
was specified when no absolute command is present.
G92 was specified in the block in which G49 is present.
Number
Message
Contents
PS5406
G41.3/G40 FORMAT ERROR
The G41.3 or G40 block contains a move command.
The G41.3 block contains a G or M code that suppresses buffering.
Number
Message
Contents
PS5407
ILLEGAL COMMAND IN G41.3
In the G41.3 mode, a G code of group 01 other than G00 and G01 is specified.
In the G41.3 mode, an offset command (a G code of group 07) is specified.
The block next to G41.3 (startup) specifies no movement.
Number
Message
Contents
PS5408
G41.3 ILLEGAL START_UP
In a mode of group 01 other than G00 and G01, G41.3 (startup) is specified.
The included angle between the tool vector and move vector is 0 or 180 degrees at the
time of startup.
Number
Message
Contents
PS5420
ILLEGAL PARAMETER IN G43.4/G43.5
A parameter related to tool center point control is illegal.
Acceleration/deceleration before interpolation is disabled. Set parameter No. 1660.
Rapid traverse acceleration/deceleration before interpolation is disabled. Set bit 1 (LRP)
of parameter No. 1401, bit 5 (FRP) of parameter No. 19501, and parameters Nos.
No.1671 and 1672.
The AI contour control function is unavailable.
Set bit 2 (AAI) of parameter No. 11260 to 0.
Number
Message
Contents
PS5421
ILLEGAL COMMAND IN G43.4/G43.5
An illegal command was specified in tool center point control.
371
Alarm list
B-64805EN/03
A rotation axis command was specified in tool center point control (type 2) mode.
With a table rotary type or mixed-type machine, a I, J, or K command was specified in the
tool center point control (type 2) (G43.5) block.
A command that does not move the tool center point (only a rotation axis is moved) was
specified for the workpiece in the G02/G03 mode.
When the workpiece coordinate system is set as the programming coordinate system (bit
5 (WKP) of parameter No. 19696 is 1), G02 or G03 was specified while the rotation axis
was not perpendicular to the plane.
A G code not specifiable during the tool center point control mode was specified.
The modal code used to specify tool center point control is incorrect.
If, in tool center point control mode, any of the following conditions is met, an axis not
related to tool center point control (non 5-axis machining control axis) is specified:
The tool center point control command axis extension function is not available
The number of non 5-axis machining control axes exceeds the maximum number
of axes that can be specified.
Nano smoothing or NURBS interpolation is performed.
When bit 0 (RCM) of parameter No. 11200 is set to 0 to disable tool direction
compensation, tool center point control is specified during the workpiece setting error
compensation/tilted working plane indexing command mode.
When tool posture control is enabled in tool center point control (type 2), a command that
results in a near-singular point tool posture was issued (it is possible to not display the
alarm by setting bit 3 (NPC) of parameter No. 19696). Review the machine configuration
and command.
When tool posture control is enabled under tool center point control (type 1), a rotary axis
angular displacement that disables tool posture control is specified. Review the machine
configuration and command.
During tool center point control (type 2) or tool posture control, nano smoothing or NURBS
interpolation is specified. Check the specification.
For nano smoothing in tool center point control (type 1), only linear axes are specified as
axes for nano smoothing. Specify rotation axes.
In a state in which the shift of a mirror image remains, tool center point control, tool
posture control, or the cutting point command is specified.
Intervened with a MDI command while a single block was stopped in high-speed smooth
TCP mode.
Either of the following conditions were met in the "table rotation type" or "mixed type"
machine.
Manual intervention was performed on the rotary axis during tool center point
control mode.
Tool center point control was specified while the manual intervention amount for
the rotary axis is not 0.
When the tool management function is enabled, H/D and P commands were
simultaneously specified in the tool center point control start block (G43.4/G43.5).
An illegal command was issued in the ",L3" command in the tool center point control (type
2) start block.
Address P is illegal.
Illegal Q address in Roll-Pitch-Yaw command "P1".
In the order of commands for tool center point control and tilted working plane indexing
commands, the one commanded first is canceled first. Cancel the one commanded later
first.
Number
Message
Contents
PS5422
EXCESS VELOCITY IN G43.4/G43.5
An attempt was made to make a movement at an axis feedrate exceeding the maximum cutting
feedrate by tool center point control.
Number
Message
Contents
PS5424
ILLEGAL TOOL DIRECTION
The rotation axis position for specifying the tool axis direction is not ±90° × n (n = 0, 1, 2,…).
Number
Message
Contents
PS5425
ILLEGAL OFFSET VALUE
The offset number is incorrect.
372
B-64805EN/03
Alarm list
Number
Message
Contents
PS5432
G02.4/G03.4 FORMAT ERROR
The 3-dimensional circular interpolation (G02.4/G03.4) has a format error.
Number
Message
Contents
PS5435
PARAMETER OUT OF RANGE (TLAC)
The parameter setting is incorrect (set value range).
Check parameters Nos. 19655, 19656, 19657, and 1022.
Number
Message
Contents
PS5436
ILLEGAL PARAMETER SETTING OF ROTARY AXIS
The parameter setting is incorrect (rotary axis setting).
Check parameter No. 19655.
Number
Message
Contents
PS5437
ILLEGAL PARAMETER SETTING OF MASTER ROTARY AXIS
The parameter setting is incorrect (master rotary axis setting).
Check parameter No. 19657.
Number
Message
Contents
PS5445
CAN NOT COMMAND MOTION IN G39
Corner circular interpolation (G39) of tool radius - tool nose radius compensation is not
specified alone but is specified with a move command. Modify the program.
Number
Message
Contents
PS5446
NO AVOIDANCE AT G41/G42
Because there is no interference avoidance vector, the interference check avoidance function
of tool radius - tool nose radius compensation does not work.
Number
Message
Contents
PS5447
DANGEROUS AVOIDANCE AT G41/G42
The interference check avoidance function of tool radius - tool nose radius compensation
operation will lead to danger.
Number
Message
Contents
PS5448
INTERFERENCE TO AVD. AT G41/G42
In the interference check avoidance function of tool radius - tool nose radius compensation, a
further interference occurs for an already created interference avoidance vector.
Number
Message
Contents
PS5456
TOO MANY G68.2 NESTING
The tilted working plane indexing command (G68.2) was specified twice or more.
To perform another coordinate conversion, perform cancellation, then specify the coordinate
conversion.
Number
Message
Contents
PS5457
G68.2 FORMAT ERROR
A G68.2 format error occurred.
Number
Message
Contents
PS5458
ILLEGAL USE OF G53.1/G53.6
G53.1 or G53.6 was specified preceding G68.2.
373
Alarm list
B-64805EN/03
G53.1 or G53.6 was not specified independently.
There is no angle solution for the rotation axis that controls the tool axis direction in the
+Z-axis direction of the feature coordinate system.
In the setting by which compensation in the tool direction is not performed (when bit 0
(PCM) of parameter No. 11200 is 0), G53.1 was specified in the workpiece placement
error compensation mode.
No tool is specified with a G53.6 command.
Number
Message
Contents
PS5459
MACHINE PARAMETER INCORRECT
One of parameters Nos. 19665 to 19667, Nos.19680 to 19714 and No. 12321 used to
configure the machine contains an error.
The axis specified with parameter No. 19681 or No. 19686 is not a rotary axis.
In parameter No. 1022, the basic three axes are not set.
A rotary axis end point found by the CNC with tool center point control type 2, 3dimensional cutter compensation type 2, cutting point command type 2, or the tilted
working plane indexing is not within the range set by parameter No. 19741 to No. 19744.
The rotary axis end point was not found with tool center point control type 2, 3dimensional cutter compensation type 2, or cutting point command type 2 . Review the
machine configuration and command.
On a machine whose rotary axis is a virtual axis, tool center point control type 2, 3dimensional cutter compensation type 2, or cutting point command type 2 was specified.
When programming is configured to be performed in the workpiece coordinate system,
tool center point control type 2, 3-dimensional cutter compensation type 2, or cutting point
command type 2 is specified.
If a parameter for setting a 5-axis function, the reference rotation axis position, is to be set
in the machine coordinate system (bit 7 (SPM) of parameter No. 19754 = 1), an inclined
rotary axis is used.
The same value is set for parameters No. 19681 and No. 19686 (the controlled axis
number of the rotary axis) in tool center point control.
The tool rotation axis rotating around the vertical axis in the plane performing tool nose
radius compensation does not exist when tool nose radius compensation for imaginary
tool noses No. 1 to 8 is used together with tool center point control.
If bit 7 (AIR) of parameter No. 11221 is set to 1, tool direction control (G53.1/G53.6) is
specified in the following illegal parameter settings.
Rotary axis motion range is set for the axis with roll-over enabled.
Roll-over is enabled for the axis set as a rotary axis (B type).
Number
Message
Contents
PS5460
ILLEGAL USE OF 3-DIMENSIONAL CUTTER COMPENSATION
In the 3-dimensional cutter compensation mode (except the tool side offset function for a
tool rotation type machine), a move command other than G00/G01 is specified.
With a table rotation type machine, when bit 1 (PTD) of parameter No. 19746 is set to 1, a
plane selection is made with an axis other than the basic three axes at the start of 3dimensional cutter compensation.
When bit 1 (SPG) of parameter No. 19607 is set to 1, there is a discrepancy between the
machine type set in parameter No. 19680 and a G code specifying 3-dimensional cutter
compensation (G41.2, G42.2, G41.4, G42.4, G41.5, or G42.5).
With a machine that is not of the tool rotation type, G41.3 is specified.
When bit 5 (WKP) of parameter No. 19696 is set to 0, and bit 4 (TBP) of parameter No.
19746 is set to 0, 3-dimensional cutter compensation and tool center point control are
used at the same time.
A rotation axis command is specified in the 3-dimensional cutter compensation mode
(type 2).
With a table rotation type or mixed type machine, IJK is specified in a block that specifies
3-dimensional cutter compensation (type 2) (G41.6/G42.6).
An illegal G code is specified in the 3-dimensional cutter compensation mode.
When 3-dimensional cutter compensation is specified, the modal state is illegal.
When the table coordinate system is set as the programming coordinate system, table
rotate and 3-dimensional cutter compensation are specified after the start of tool center
point control.
There is a difference in type1/type 2 specification between 3-dimensional cutter
compensation and tool center point control.
374
B-64805EN/03
Alarm list
When 3-dimensional cutter compensation and tool center point control are used at the
same time, one of these functions that is specified earlier than the other is canceled
earlier.
A value other than 0 or 9 is specified as an imaginary tool nose number.
Number
Message
Contents
PS5461
ILLEGAL USE OF G41.2/G42.2/G41.5/G42.5
A move command other than G00 or G01 was performed during 3-dimensional cutter
compensation (G41.2/G42.2, or G41.5/G42.5) in a mixed-type machine.
Number
Message
Contents
PS5462
ILLEGAL COMMAND (G68.2/G69)
The modal setting used when G68.2 or G69 is specified is incorrect.
An unspecifiable G code was specified in the G68.2 mode.
The offset vector of tool radius - tool nose radius compensation is not canceled when
G68.2 or G69 is specified.
Number
Message
Contents
PS5463
ILLEGAL PARAMETER IN 3-DIMENSIONAL CUTTER COMPENSATION
A parameter related to 3-dimensional cutter compensation is illegal.
Acceleration/deceleration before interpolation is disabled. Set parameter No. 1660.
Rapid traverse acceleration/deceleration before interpolation is disabled. Set bit 1 (LRP)
of parameter No. 1401, bit 5 (FRP) of parameter No. 19501, and parameters Nos.
No.1671 and 1672.
Number
Message
Contents
PS5464
ILLEGAL COMMAND IN G43.8/G43.9
An illegal value is specified with the cutting point command of tool center point control.
A negative value is set to the parameter (No.11419).
In case of tool offset memory A and B of machining center system, D code is specified in
G43.8/G43.9 block.
In case of tool offset memory C and bit 3 (ON1) of parameter No. 11269 is 1 in machining
center system, D code is specified in G43.8/G43.9 block.
All of (I, J, K) following ",L2" are specified as 0.
A value is specified that causes the angle formed by the tool length compensation
direction and the direction perpendicular to the cutting surface to exceed 90 degrees.
The tool radius offset is less than the corner-R offset.
On a tool rotation type machine, manual intervention is performed on the rotation axis.
An illegal G code was specified in cutting point command mode.
Number
Message
Contents
PS5523
WAITING THE OPTION CERTIFICATION
CNC is under the option certification waiting state.
This alarm can be cleared by the reset operation before the expiration date (30 days after
generating the alarm).
As for the certification operation to clear this alarm permanently, please contact the
FANUC service division by the above date.
When the certification operation is not executed by the expiration date, the alarm PS5524
occurs. This alarm cannot be cleared by the reset operation.
Number
Message
Contents
PS5524
OPTION CERTIFICATION (EXPIRE)
The option certification waiting state was expired.
This alarm cannot be cleared by the reset operation.
As for the certification operation to clear this alarm permanently, please contact the
FANUC service division.
Number
PS5557
375
Alarm list
B-64805EN/03
Message
Contents
NO MAX SP SPEED CLAMP COMMAND
No command for maximum spindle speed clamping (M series: G92S_; T series: G50 S_ ; ) was
not executed before the constant surface speed control command (G96 S_ ; ) was started.
Execute a command for maximum spindle speed clamping.
Number
Message
Contents
PS5558
ILLEGAL ESCAPING/RETURN AMOUNT
Please correct the program.
Number
Message
Contents
PS5559
ILL. AXIS OPERATION (COORD SYS)
When the parameter MSC(No.11501#2)=1, and the workpiece coordinate system is shifted
from the machine coordinate system by the movement command in the machine lock state, the
axis movement was commanded. Please operate "reference position return" or "workpiece
coordinate system preset" etc. This alarm is enabled when bit 2 (MSC) of parameter No. 11501
is set to 1.
Furthermore, the machine lock shift amount check in the 5-axis machining function is enabled
when bit 6 (M5D) of parameter No. 11224 is 0.
Number
Message
Contents
PS5560
ILLEGAL DEPTH OF CUT
On the peck rigid tapping, a value where the depth of cut (Q) is smaller than the cutting start
distance was specified.
Number
Message
Contents
PS5561
CANCEL CANNED GRINDING CYCLE
A multiple repetitive cycle was specified without cancelling the canned grinding cycle.
Specify the 01 group G code to cancel the canned grinding cycle.
Number
Message
Contents
PS5577
ILLEGAL AXIS SELECTED (G05)
The number of controlled axes set in bit 0 (HAS) of parameter No. 7506 is "0" or the maximum
number of controlled axes of high-speed cycle cutting or high-speed binary program operation
is exceeded.
Number
Message
Contents
PS5579
ILLEGAL COMMAND OF OSCILLATION
The format of the servo learning oscillation program command is illegal.
The value range of oscillation frequency I and oscillation amplitude K in the program
command is illegal.
The non-oscillation axis (bit 1 (SVOSCI) of parameter No. 2439 = 0) is set as a one-axis
oscillation-specified axis.
The one-axis oscillation-specified axis was set for multiple axes.
Number
Message
Contents
PS5580
CANNOT GET SYSTEM VARIABLE
System variables #180801 to #180850T cannot be loaded because the value of parameter No.
8311 is illegal.
Check the settings of parameter No. 8311.
Number
Message
Contents
PS5582
ILLEGAL COMMAND OF CS CONTROL
A command to travel to Cs axis and S code were simultaneously specified.
Number
PS5583
376
B-64805EN/03
Alarm list
Message
Contents
EXPIRING, AUTOMATIC OPERATION WILL BE IMPOSSIBLE (CNC LOCK)
In the CNC lock function, the remaining days until expiration date is within seven days (or the
setting value of parameter No. 24749). Refer to the CNC lock screen.
If it expires, automatic operation of the CNC will not be possible. Make sure to attend to it
before the expiration date.
The expiration date cannot be changed by Fanuc. Contact the machine dealer or leaser to
extend the expiration date.
Automatic operation does not stop even if this alarm is generated.
This alarm can be cleared by a reset. Even if this alarm is cleared, it will be generated again
when the CNC date changes.
Number
Message
Contents
PS5585
EXCESS OSCILLATION FREQ MULTIPLE
The applied oscillation frequency has exceeded its upper limit. Check the following.
The I command value of the G8.5 block.
Parameter No. 25692:
Parameter No. 25694 and the setting value of its address.
Parameter No. 25697:
Number
Message
Contents
PS5586
EXCESS OSCILLATION AMP MULTIPLE
The applied oscillation amplitude has exceeded its upper limit. Check the following.
The K command value of the G8.5 block.
Parameter No. 25693:
Parameter No. 25695 and the setting value of its address.
Parameter No. 25698:
Number
Message
Contents
PS5587
ILLEGAL COMMAND SETTING OF SP
Bit 1 (CSD) and bit 2 (SPC) of parameter No. 3791 are 1.
Bit 0 (SPC) of parameter No. 11000 and bit 2 (SPC) of parameter No. 3791 are 1.
Number
Message
Contents
PS5588
ILLEGAL COMMAND OF SP (S-CODE)
Both an S code and axis address were specified for the same spindle.
Number
Message
Contents
PS5589
ILLEGAL COMMAND OF SP (MULTI-SP)
Mode switching was specified for multiple spindles in one block.
Number
Message
Contents
PS5590
ILLEGAL SVREV MODE SWITCHING
Control mode switching was executed via a signal during a control mode switch command.
Number
Message
Contents
PS5591
RAPID TRAVERSE RATE COMMAND IS 0
The rapid traverse rate command is 0.
0 cannot be specified for the rapid traverse rate.
Number
Message
Contents
PS5592
ILLEGAL COMMAND OF SP (G-CODE)
A one-shot G code was specified in the block switching to position control mode with a G00
command, and the block switching to SV rotation control mode with an S code.
377
Alarm list
B-64805EN/03
Number
Message
Contents
PS5593
ILLEGAL COMMAND OF SP (P-CODE)
A P code was specified in the block switching to position control mode with a G00 command,
and the block switching to SV rotation control mode with a spindle name expansion.
Number
Message
Contents
PS5594
ILLEGAL COMMAND OF SP (R-CODE)
An R code was specified in the block switching to position control mode with G00 command.
Number
Message
Contents
PS10000
ILLEGAL FOR STATEMENT FORMAT
There is an error in the format of the FOR statement. Possible causes are as follows.
1. Format error
- Not FOR (<initialization of counter variable>, <end value>,<tick width>)
- Not FOR (<initialization of counter variable>, <end value>)
2. Brace "{" is missing
Number
Message
Contents
PS10001
ILLEGAL ARGUMENT IN FOR STATEMENT
In the FOR statement, the counter variable has an initial value, an end value, and a tick width
value that are not in the range of -2147483648 to 2147483647. (An <empty> or a tick width of 0
is also considered out of range.)
Number
Message
Contents
PS10002
PROGRAM BLOCK LENGTH OVER
The string of one block string is too long.
Number
Message
Contents
PS10003
PROGRAM FILE CHECK SUM ERROR
A checksum error occurred in the NC program.
Number
Message
Contents
PS10004
TOO MANY BRACKET NEST IN EXPRESSION
The multiplicity of parentheses in the formula exceeded the upper limit.
Review the program to avoid it from be too complicated, e.g., using variables to divide the
calculation into two blocks.
Number
Message
Contents
PS10005
TOO MANY MULTI BLOCK NESTING
Nest multiplicity for repeated syntax (WHILE/FOR) surrounding multiple blocks has exceeded
the upper limit. Up to 51 levels can be used per path.
Number
Message
Contents
PS10006
CANNOT JUMP INTO WHILE/FOR/SWITCH NEST
An attempt has been made to branch within the range of the repeated syntax (WHILE/FOR)
using commands such as GOTO. It cannot be branched that way.
Number
Message
Contents
PS10007
ELSE WITHOUT IF STATEMENT
There is no IF statement corresponding to ELSE
378
B-64805EN/03
Alarm list
Number
Message
Contents
PS10008
OPEN CURLY BRACKET NOT FOUND
No beginning of multi-block nesting
Number
Message
Contents
PS10009
MISSING EXPECTED OPEN BRACKET
Where parentheses are required, the rest of the content is written
Number
Message
Contents
PS10010
MISSING EXPECTED CLOSE BRACKET
Where the corresponding closing parentheses should be is written with something else.
Number
Message
Contents
PS10011
SWITCH STATEMENT FORMAT ERROR
The format of SWITCH statement is incorrect. Possible causes are as follows.
Not in the form of SWITCH(<expression>).
SWITCH(<expression>) is followed by an NC statement or a statement that cannot be
parsed
Number
Message
Contents
PS10012
SWITCH STATEMENT ERROR
There is an error in the execution of the SWITCH statement. Possible causes are as follows.
1. SWITCH statement cannot be executed correctly
- Execute the SWITCH statement again in the middle of processing the SWITCH
statement.
- SWITCH(<expression>) is not followed by EOB, CASE, or DEFAULT.
2. The value of the result of <expression> evaluation is out of range (-2147483648 to
2147483647)
3. The branch destination of GOTO is within the nesting range of the SWITCH statement.
Number
Message
Contents
PS10013
CASE STATEMENT ERROR
CASE statement error. Possible causes are as follows.
1. A CASE statement is commanded while the SWITCH statement is not executed.
2. Improper format.
- Not in the form of CASE[<expression>].
- CASE(<expression>) is not followed by a GOTO
3. The value of the result of <expression> evaluation is out of range (-2147483648 to
2147483647)
Number
Message
Contents
PS10014
DEFAULT STATEMENT ERROR
DEFAULT statement error. Possible causes are as follows.
1. A DEFAULT statement is commanded while the SWITCH statement is not executed.
2. Improper format.
- DEFAULT is not followed by EOB or GOTO
Number
Message
Contents
PS10015
STRING VARIABLE LENGTH OVER
Assigning a string that exceeds the length of the string that can be assigned to a string type
variable.
Number
Message
Contents
PS10016
WAITMU COMMAND ERROR
Possible causes are as follows.
379
Alarm list
B-64805EN/03
When different standby numbers are commanded for different paths in the standby
command WAITMU
In WAITMU, if the standby number matches but the designated path does not match
Number
Message
Contents
PS10017
NOTIFY COMMAND ERROR
The wait number specified for the wait release command NOTIFY is already specified for a
different NOTIFY.
Number
Message
Contents
PS10018
ARRAY VARIABLE LENGTH MISMATCH
There is an error in the array variable assignment. The lengths of the arrays on the two sides
are different.
Number
Message
Contents
PS10019
UNAVAILABLE PMC ADDRESS BY SYSTEM VARIABLE
The signal address to be read or written cannot be used in the system variables for signals.
Signal addresses M and N are not readable when the PMC inter-path interface function is not
used (parameter No. 11932 = 0).
Number
Message
Contents
PS10020
CONTROL COMMAND NEST OVER
The multiplicity of Motion Script control commands has exceeded the limit
Number
Message
Contents
PS10021
ILLEGAL COMMAND ORDER
There is an error in the order of commands in Motion Script.
G65 or CANCEL is not commanded alone
Incorrect IF-ELSE nesting
M99 was commanded when not during a call
Number
Message
Contents
PS10022
ILLEGAL WORD FOR CUSTOM MACRO
Commands specific to Motion Script were used in custom macros. (ONCE, EDGE, etc.)
Number
Message
Contents
PS10023
ILLEGAL WORD FOR MOTION SCRIPT
Commands that cannot be used in the Motion Script function were used (GOTO, SETVN,
SWITCH, FOR, etc.)
Number
Message
Contents
PS10024
MOTION SCRIPT NUMBER ILLEGAL
In Motion Script, an integer value such as a number is out of range.
Number
Message
Contents
PS10025
MOTION SCRIPT START DUPLICATE
An attempt has been made to start a command with "&" again during a Motion Script
command.
Number
Message
Contents
PS10031
DEVICE NOT FOUND(SD CARD)
The SD card (NC_DATA) on the control unit side is not found.
Check that the SD card is properly inserted into the slot on the CNC control unit side.
380
B-64805EN/03
Alarm list
Number
Message
Contents
PS10032
FILE NOT FOUND(SD CARD)
The specified file cannot be found on the SD card (NC_DATA).
Verify that the specified file exists.
Number
Message
Contents
PS10033
FOLDER/FILE EXIST(SD CARD)
The specified folder or file exists on the SD card (NC_DATA).
Delete the specified folder or file in advance.
Number
Message
Contents
PS10034
DEVICE FULL(SD CARD)
Insufficient free capacity on the control unit-side SD card.
Please increase the free space and try again.
Number
Message
Contents
PS10101
CURRENTLY SAFETY PARAMETERS CANNOT BE CHANGED
Safety parameters cannot be changed except in the Setup Mode.
Number
Message
Contents
PS10107
CANNOT CHANGE SAFETY PARAMETER BY EXECUTED METHOD
Parameters (No.1946, No.13918, No.41087, No.41088, No.41089, No.41090, No.41091,
No.41092) cannot be changed by the following methods during the acceptance test mode.
Parameter file input
Programmable parameter input (G10L52)
Macro executor (G314)
Number
Message
PS10203
CAN NOT COMMAND 3-D OFFSET IN SCALING WITH DIFFERENT MAGNIFICATIONS FOR
EACH AXIS
3-dimensional tool compensation cannot be commanded while scaling with different
magnifications for each axis.
Contents
Number
Message
Contents
Number
Message
Contents
PS10204
CAN NOT COMMAND CIRCULAR/INVOLUTE INTERPOLATION OR CORNER R IN
SCALING WITH DIFFERENT MAGNIFICATIONS FOR EACH AXIS
Circular/involute interpolation or corner R cannot be commanded while scaling with different
magnifications for each axis.
Set bit 1 (CIS) of parameter No. 41603 to 1 to ensure these can be commanded in the FS500i
specifications, which applies to the end point coordinate values and the intermediate path.
PS10205
CAN NOT COMMAND HELICAL INTERPOLATION OR HELICAL INVOLUTE
INTERPOLATION IN SCALING
Helical interpolation or helical involute interpolation cannot be commanded during scaling.
Modify the program.
Number
Message
Contents
PS10400
WRITE PROTECT VALUE (#_LSW)
A write command was given to #_LSW.
Number
Message
PS10401
INVALID OPTION (STORED STROKE LIMIT RANGE SWITCHING FUNCTION BY SIGNAL)
381
Alarm list
B-64805EN/03
Contents
There is no option for the stored stroke limit range switching function by signal.
Number
Message
Contents
PS10404
ILLEGAL COMMAND IN G72.1/G72.2
Command format is wrong in the figure copy.
In the case of rotational copy, the coordinates of rotation center were commanded to an axis
other than the plane selection axes.
In the case of linear copy, the shift amount was commanded to an axis other than the plane
selection axes.
2.1.2.
Background Edit Alarms (BG Alarm)
Number
Message
Contents
BG0070
NO PROGRAM SPACE IN MEMORY
The memory area is insufficient. Delete any unnecessary programs, then retry.
Number
Message
Contents
BG0072
TOO MANY PROGRAMS
The number of registered programs has exceeded 63 or 125, 200, 400, or 1000.
Delete unnecessary programs and execute program registration again.
Number
Message
Contents
BG0073
PROGRAM NUMBER ALREADY IN USE
The commanded program number has already been used. Change the program number or
delete unnecessary programs and execute program registration again.
Number
Message
Contents
BG0075
PROTECT
An attempt was made to register a program whose number was protected.
In program matching, the password for the encoded program was not correct.
Number
Message
Contents
BG0085
OVERRUN ERROR
The next character was received from the I/O device connected to RS232C interface 1 before it
could read a previously received character.
The cause may be a defective I/O device or a defective print plate.
Number
Message
Contents
BG0086
DR OFF
For data input/output by RS-232C interface 1, the I/O device operation reparation signal (DR) is
turned OFF. Possible causes are an I/O device not turned on, a broken cable, and a defective
printed circuit board.
Number
Message
Contents
BG0087
BUFFER OVERFLOW
The buffer received from the I/O device connected to the RS232C interface 1 has overflowed.
This may be due to a defective I/O device or print plate, or the fact that data was sent despite
the fact that CNC reception was stopped during flow control.
Number
Message
BG0140
PROGRAM NUMBER ALREADY IN USE
382
B-64805EN/03
Alarm list
Contents
In the background, an attempt was made to select or delete the program being selected in the
foreground. Operate properly for the background editing.
Number
Message
Contents
BG0233
DEVICE BUSY
When an attempt was made to use a unit such as that connected via the RS-232-C interface,
other users were using it.
Number
Message
Contents
BG0434
WRITE PROTECT
Program registration operation is prohibited.
Number
Message
Contents
BG0435
ILLEGAL FORMAT
The format is illegal.
Re-check the program number and the file name format set in the program.
Number
Message
Contents
BG1590
TH ERROR
A TH error was detected during reading from an input device. The read code that caused the
TH error and how many statements it is from the block can be verified in the diagnostics
screen.
Number
Message
Contents
BG1591
TV ERROR
An error was detected during the single-block TV error. The TV check can be suppressed by
setting bit 0 (TVC) of parameter No. 0000 to "0".
Number
Message
Contents
BG1805
ILLEGAL COMMAND
[I/O Device]
An attempt was made to specify an illegal command during I/O processing on an I/O device.
[G30 reference position return]
The P address numbers for instructing No. 2 to No. 4 reference position return are each out of
the range 2 to 4.
[Single Rotation Dwell]
The specified spindle rotation is "0" when single rotation dwell is specified.
Number
Message
Contents
BG1806
DEVICE TYPE MISS MATCH
An operation not possible on the I/O device that is currently selected in the setting was
specified.
This alarm is also generated when file rewind is instructed even though the I/O device is not a
FANUC Cassette.
Number
Message
Contents
BG1807
PARAMETER SETTING ERROR
An I/O interface option that has not yet been added on was specified.
The external I/O device and baud rate, stop bit and protocol selection settings are erroneous.
Number
Message
Contents
BG1808
DEVICE DOUBLE OPENED
An attempt was made to open a device that is being accessed.
383
Alarm list
B-64805EN/03
Number
Message
Contents
BG1823
FRAMING ERROR(1)
The stop bit of the character received from the I/O device connected to RS-232C interface 1
was not detected.
Number
Message
Contents
BG1830
DR OFF(2)
For data input/output by RS-232C interface 2, the I/O device operation reparation signal (DR) is
turned OFF. Possible causes are an I/O device not turned on, a broken cable, and a defective
printed circuit board.
Number
Message
Contents
BG1832
OVERRUN ERROR(2)
The next character was received from the I/O device connected to RS232C interface 2 before it
could read a previously received character.
The cause may be a defective I/O device or a defective print plate.
Number
Message
Contents
BG1833
FRAMING ERROR(2)
The stop bit of the character received from the I/O device connected to RS-232C interface 2
was not detected.
Number
Message
Contents
BG1834
BUFFER OVERFLOW(2)
The buffer received from the I/O device connected to the RS232C interface 2 has overflowed.
This may be due to a defective I/O device or print plate, or the fact that data was sent despite
the fact that CNC reception was stopped during flow control.
Number
Message
Contents
BG1912
V-DEVICE DRIVER ERROR(OPEN)
An error occurred during device driver control.
Number
Message
Contents
BG1919
FATAL ERROR(USB MEMORY)
A fatal error occurred in the USB file system. To restore the file system, turn the power off.
Number
Message
Contents
BG1924
UNEXPECTED ERROR(USB MEMORY)
An unexpected error occurred in the USB file system.
Number
Message
Contents
BG1925
ILLEGAL PATH/FILE(USB MEMORY)
An invalid path or file name was specified.
Number
Message
Contents
BG1926
ACCESS DENIED(USB MEMORY)
The USB memory could not be accessed.
Number
Message
Contents
BG1927
DEVICE IN FORMATTING(USB MEMORY)
The USB memory is being formatted.
384
B-64805EN/03
Alarm list
Number
Message
Contents
BG1928
DEVICE NOT FOUND(USB MEMORY)
No USB memory is inserted. Check the connection.
Number
Message
Contents
BG1932
DEVICE IS FULL(USB MEMORY)
The capacity of the USB memory is insufficient.
Number
Message
Contents
BG1937
RECOGNITION ERROR(USB MEMORY)
The format of the USB memory is invalid. Format the USB memory in FAT or FAT32 format. If
the alarm is still issued, replace the USB memory.
Number
Message
Contents
BG1938
END OF FILE FOUND(USB MEMORY)
The end of file was detected before EOR(%) was read. The file may be corrupted.
Number
Message
Contents
BG1939
UNDEFINED ERROR(USB MEMORY)
An undefined error occurred.
Number
Message
Contents
BG1951
DEVICE IS BUSY(USB MEMORY)
The USB memory is busy.
Number
Message
Contents
BG1952
TOO MANY FILES(USB MEMORY)
The maximum number of files that can be opened concurrently is exceeded.
Number
Message
Contents
BG1953
REMOVED IN ACCESSING(USB MEMORY)
The USB memory was removed while being accessed.
Number
Message
Contents
BG1954
PATH/FILE EXIST(USB MEMORY)
The specified path or file already exists.
Number
Message
Contents
BG1955
PATH/FILE NOT FOUND(USB MEMORY)
The specified path or file is not found.
Number
Message
Contents
BG1956
DEVICE OVERCURRENT(USB MEMORY)
Overcurrent was detected in the USB memory. Replace the USB memory.
Number
Message
Contents
BG1957
PARITY ERROR(USB MEMORY)
A parity error occurred in the USB memory. Turn the power to the CNC off.
Number
Message
BG1960
ACCESS ERROR(SD CARD ON THE CONTROL UNIT)
385
Alarm list
B-64805EN/03
Contents
Illegal SD card access on the control unit side.
This alarm is also generated during reading when reading is executed up to the end of the file
without detection of the EOR code.
Number
Message
Contents
BG1961
NOT READY(SD CARD ON THE CONTROL UNIT)
SD card on the control unit side is not ready.
Number
Message
Contents
BG1962
CARD FULL(SD CARD ON THE CONTROL UNIT)
Insufficient space on the SD card at the control unit side.
Number
Message
Contents
BG1963
CARD FULL(SD CARD ON THE CONTROL UNIT)
SD card on the control unit side is write-protected.
Number
Message
Contents
BG1964
NOT MOUNTED(SD CARD ON THE CONTROL UNIT)
The SD card on the control unit side cannot be recognized.
Number
Message
Contents
BG1965
DIRECTORY FULL(SD CARD ON THE CONTROL UNIT)
The file could not be generated in the root directory for the SD card on the control unit side.
Number
Message
Contents
BG1966
FILE NOT FOUND(SD CARD ON THE CONTROL UNIT)
The specified file could not be found on the SD card on the control unit side.
Number
Message
Contents
BG1967
FILE FULL(SD CARD ON THE CONTROL UNIT)
SD card on the control unit side is write-protected.
Number
Message
Contents
BG1968
ILLEGAL FILE NAME(SD CARD ON THE CONTROL UNIT)
Illegal file name on the SD card on the control unit side.
Number
Message
Contents
BG1969
ILLEGAL FORMAT(SD CARD ON THE CONTROL UNIT)
Check the SD card on the control unit side.
Number
Message
Contents
BG1970
ILLEGAL CARD(SD CARD ON THE CONTROL UNIT)
The SD card on the control unit side cannot be recognized.
Number
Message
Contents
BG1971
ERASE ERROR(SD CARD ON THE CONTROL UNIT)
An error occurred during the SD card on the control unit side erase.
Number
Message
Contents
BG1972
BATTERY LOW(SD CARD ON THE CONTROL UNIT)
The battery voltage of the SD card on the control unit side is low.
386
B-64805EN/03
Alarm list
Number
Message
Contents
BG1973
FILE ALREADY EXIST
A file having the same name already exists on the SD card on the control unit side. Check the
file name. When overwriting a file, performing it after deleting the file.
Number
Message
Contents
BG5583
EXPIRING, AUTOMATIC OPERATION WILL BE IMPOSSIBLE (CNC LOCK)
In the CNC lock function, the remaining days until expiration date is within seven days (or
parameter No. 24749 setting value). Refer to the CNC lock screen.
If it expires, automatic operation of the CNC will not be possible. Make sure to attend to it
before the expiration date.
The expiration date cannot be changed by Fanuc. Contact the machine dealer or leaser to
extend the expiration date.
Automatic operation does not stop even if this alarm is generated.
This alarm can be cleared by a reset. Even if this alarm is cleared, it will be generated again
when the CNC date changes.
2.1.3.
Communication Alarms (SR Alarm)
Number
Message
Contents
SR0001
TH ERROR
A TH error was detected during reading from an input device.
The read code that caused the TH error and how many statements it is from the block can be
verified in the diagnostics screen.
Number
Message
Contents
SR0002
TV ERROR
An error was detected during the single-block TV error.
The TV check can be suppressed by setting bit 0 (TVC) of parameter No. 0000 to "0".
Number
Message
Contents
SR0075
PROTECT
An attempt was made to register a program whose number was protected.
In program matching, the password for the encoded program was not correct.
A program in background editing was selected as the main program.
A program in background editing was called as a subprogram.
Number
Message
Contents
SR0085
OVERRUN ERROR
The next character was received from the I/O device connected to RS232C interface 1 before it
could read a previously received character.
The cause may be a defective I/O device or a defective print plate.
Number
Message
Contents
SR0087
BUFFER OVERFLOW
The buffer received from the I/O device connected to the RS232C interface 1 has overflowed.
This may be due to a defective I/O device or print plate, or the fact that data was sent despite
the fact that CNC reception was stopped during flow control.
Number
Message
SR0114
ILLEGAL EXPRESSION FORMAT
387
Alarm list
B-64805EN/03
Contents
The format used in an expression in a custom macro statement is in error.
The parameter tape format is in error.
Number
Message
Contents
SR0177
CHECK SUM ERROR(G05)
A checksum error occurred.
Number
Message
Contents
SR0178
ILLEGAL COMMAND G05
This alarm is issued in the following cases.
The settings of bits 4 to 6 of parameter No.7501 are invalid.
G05 was specified during the following modes:
Hypothetical axis interpolation (G07)
Cylindrical interpolation (G07.1)
Polar coordinate interpolation mode (G12.1)
Polar coordinate command (G16)
Spindle speed fluctuation detection (G26)
Tool radius - tool nose radius compensation (G41/G42)
Normal direction control (G41.1/G42.1)
Scaling (G51)
Programmable mirror image (G51.1)
Coordinate system rotation (G68)
Canned cycle (G81 to G89)
Constant surface speed control (G96)
Macro interruption (M96)
G05 was specified while the Servo invalidation function and the pole position
detection function are effective at the same time.
Number
Message
Contents
SR1090
PROGRAM FORMAT ERROR
A lowercase alphabetic character is found in other than an NC program statement comment
section, program name, or folder name.
Number
Message
Contents
SR1160
COMMAND DATA OVERFLOW
An overflow occurred in the position data within the CNC.
This alarm is also generated if the target position of a command exceeds the maximum stroke
as a result of calculation such as coordinate conversion, offset, or introduction of a manual
intervention amount.
Number
Message
Contents
SR1170
LOCAL VAR NAME CANNOT BE INPUT
The name of the local variable cannot be input as a file.
Modify the input file so that names are not set to local variables.
Number
Message
Contents
SR1300
ILLEGAL ADDRESS
An unusable address or the same address was specified two times or more when entering the
settings data for the CNC-integrated 3-dimensional interference check. (the Xn(xxx.xxx) format
assumes that values up to Xn are addresses)
Number
Message
Contents
SR1301
MISSING ADDRESS
There is a lack of specified addresses when entering the settings data for the CNC-integrated
3-dimensional interference check. Make sure to specify all specified addresses.
388
B-64805EN/03
Alarm list
Number
Message
Contents
SR1302
ILLEGAL DATA NUMBER
An out-of-range value is specified in "n" with "Xn(xxx.xxx)" format when entering the settings
data for the CNC-integrated 3-dimensional interference check.
Number
Message
Contents
SR1304
TOO MANY DIGIT
The specified data is exceeding the maximum digit number (9 digits) when entering the settings
data for the CNC-integrated 3-dimensional interference check.
Number
Message
Contents
SR1305
DATA OUT OF RANGE
The data with a specified range is exceeding the range when entering the settings data for the
CNC-integrated 3-dimensional interference check.
Number
Message
Contents
SR1307
ILLEGAL USE OF MINUS SIGN
A sign was specified for an address that cannot use signs when entering the settings data for
the CNC-integrated 3-dimensional interference check.
Number
Message
Contents
SR1580
ENCODE ALARM (PSWD&KEY)
When an attempt was made to read a program, the specified password did not match the
password on the tape and the password on tape was not equal to "0".
When an attempt was made to punch an encrypted tape, the password was not in the range 1
to 99999999. The password parameter is No. 3220.
Number
Message
Contents
SR1581
ENCODE ALARM (PARAMETER)
When an attempt was made to punch an encrypted tape, the punch code parameter was set to
EIA. Set parameter ISO (No.0000#1) to 1.
An incorrect instruction was specified for program encryption or protection. This alarm is
generated if an attempt is made to perform part program editing, deletion, or range-specified
output in the protected range in the lock state. Or, a program outside the protected range is
specified in rage specification output in the unlock state.
The protected range is defined from the program No. preset by parameter No. 3222 up to the
program No. preset to parameter No. 3223. When both parameters are set to "0", the protected
range becomes O9000 to O9999.
Number
Message
Contents
SR1805
ILLEGAL COMMAND
[I/O Device]
An attempt was made to specify an illegal command during I/O processing on an I/O device.
[G30 reference position return]
The P address numbers for instructing No. 2 to No. 4 reference position return are each out of
the range 2 to 4.
[Single Rotation Dwell]
The specified spindle rotation is "0" when single rotation dwell is specified.
Number
Message
Contents
SR1806
DEVICE TYPE MISS MATCH
An operation not possible on the I/O device that is currently selected in the setting was
specified.
This alarm is also generated when file rewind is instructed even though the I/O device is not a
FANUC Cassette.
389
Alarm list
B-64805EN/03
Number
Message
Contents
SR1807
PARAMETER SETTING ERROR
An input/output interface with no options is specified.
The external I/O device and baud rate, stop bit and protocol selection settings are erroneous.
Number
Message
Contents
SR1808
DEVICE DOUBLE OPENED
An attempt was made to open a device that is being accessed.
Number
Message
Contents
SR1823
FRAMING ERROR(1)
The stop bit of the character received from the I/O device connected to RS-232C interface 1
was not detected.
Number
Message
Contents
SR1830
DR OFF(2)
For data input/output by RS-232C interface 2, the I/O device operation reparation signal (DR) is
turned OFF. Possible causes are an I/O device not turned on, a broken cable, and a defective
printed circuit board.
Number
Message
Contents
SR1832
OVERRUN ERROR(2)
The next character was received from the I/O device connected to RS232C interface 2 before it
could read a previously received character.
The cause may be a defective I/O device or a defective print plate.
Number
Message
Contents
SR1833
FRAMING ERROR(2)
The stop bit of the character received from the I/O device connected to RS-232C interface 2
was not detected.
Number
Message
Contents
SR1834
BUFFER OVERFLOW(2)
The buffer received from the I/O device connected to the RS232C interface 2 has overflowed.
This may be due to a defective I/O device or print plate, or the fact that data was sent despite
the fact that CNC reception was stopped during flow control.
Number
Message
Contents
SR1912
V-DEVICE DRIVER ERROR (OPEN)
An error occurred during device driver control.
Number
Message
Contents
SR1919
FATAL ERROR(USB MEMORY)
A fatal error occurred in the USB file system. To restore the file system, turn the power off.
Number
Message
Contents
SR1924
UNEXPECTED ERROR(USB MEMORY)
An unexpected error occurred in the USB file system.
Number
Message
Contents
SR1925
ILLEGAL PATH/FILE(USB MEMORY)
An invalid path or file name was specified.
390
B-64805EN/03
Alarm list
Number
Message
Contents
SR1926
ACCESS DENIED(USB MEMORY)
The USB memory could not be accessed.
Number
Message
Contents
SR1927
DEVICE IN FORMATTING(USB MEMORY)
The USB memory is being formatted.
Number
Message
Contents
SR1928
DEVICE NOT FOUND(USB MEMORY)
No USB memory is inserted. Check the connection.
Number
Message
Contents
SR1932
DEVICE FULL(USB MEMORY)
The capacity of the USB memory is insufficient.
Number
Message
Contents
SR1937
DEVICE IS BROKEN(USB MEMORY)
The format of the USB memory is invalid. Format the USB memory in FAT or FAT32 format. If
the alarm is still issued, replace the USB memory.
Number
Message
Contents
SR1938
END OF FILE FOUND(USB MEMORY)
The end of file was detected before EOR(%) was read. The file may be corrupted.
Number
Message
Contents
SR1939
UNDEFINED ERROR(USB MEMORY)
An undefined error occurred.
Number
Message
Contents
SR1951
DEVICE IS BUSY(USB MEMORY)
The USB memory is busy.
Number
Message
Contents
SR1952
TOO MANY FILES(USB MEMORY)
The maximum number of files that can be opened concurrently is exceeded.
Number
Message
Contents
SR1953
REMOVED IN ACCESSING(USB MEMORY)
The USB memory was removed while being accessed.
Number
Message
Contents
SR1954
PATH/FILE EXIST(USB MEMORY)
The specified path or file already exists.
Number
Message
Contents
SR1955
PATH/FILE NOT FOUND(USB MEMORY)
The specified path or file is not found.
Number
SR1956
391
Alarm list
B-64805EN/03
Message
Contents
DEVICE OVERCURRENT(USB MEMORY)
Overcurrent was detected in the USB memory. Replace the USB memory.
Number
Message
Contents
SR1957
PARITY ERROR(USB MEMORY)
A parity error occurred in the USB memory. Turn the power to the CNC off.
Number
Message
Contents
SR1960
ACCESS ERROR (SD CARD ON THE CONTROL UNIT)
Illegal SD card access on the control unit side
The specified file name is not found.
This alarm is also generated during reading when reading is executed up to the end of the file
without detection of the EOR code.
Number
Message
Contents
SR1961
NOT READY (SD CARD ON THE CONTROL UNIT)
SD card on the control unit side is not ready.
Set the SD card on the control unit side.
Number
Message
Contents
SR1962
CARD FULL (SD CARD ON THE CONTROL UNIT)
Insufficient space on the SD card at the control unit side. Delete unnecessary files to increase
the free space on the SD card on the control unit side.
Number
Message
Contents
SR1963
CARD PROTECTED (SD CARD ON THE CONTROL UNIT)
SD card on the control unit side is write-protected.
Number
Message
Contents
SR1964
NOT MOUNTED (SD CARD ON THE CONTROL UNIT)
The SD card on the control unit side cannot be recognized.
Number
Message
Contents
SR1965
DIRECTORY FULL (SD CARD ON THE CONTROL UNIT)
The file could not be generated in the root directory for the SD card on the control unit side.
Number
Message
Contents
SR1966
FILE NOT FOUND (SD CARD ON THE CONTROL UNIT)
The specified file could not be found on the SD card on the control unit side.
Number
Message
Contents
SR1967
FILE PROTECTED (SD CARD ON THE CONTROL UNIT)
SD card on the control unit side is write-protected.
Number
Message
Contents
SR1968
ILLEGAL FILE NAME (SD CARD ON THE CONTROL UNIT)
Illegal file name on the SD card on the control unit side.
Number
Message
Contents
SR1969
ILLEGAL FORMAT (SD CARD ON THE CONTROL UNIT)
Check the SD card on the control unit side.
392
B-64805EN/03
Alarm list
Number
Message
Contents
SR1970
ILLEGAL CARD (SD CARD ON THE CONTROL UNIT)
The SD card on the control unit side cannot be recognized.
Number
Message
Contents
SR1971
ERASE ERROR (SD CARD ON THE CONTROL UNIT)
An error occurred during erasing the SD card on the control unit side.
Number
Message
Contents
SR1972
BATTERY LOW (SD CARD ON THE CONTROL UNIT)
The battery voltage of the SD card on the control unit side is low.
Number
Message
Contents
SR1973
FILE ALREADY EXIST
A file having the same name already exists on the SD card on the control unit side. Check the
file name. When overwriting a file, performing it after deleting the file.
Number
Message
Contents
SR1975
NC DATA OUTPUT ERROR
An error occurred while outputting data in NC data output function.
Number
Message
Contents
SR2050
#200-#999ILLEGAL INPUT(UNMATCHED P-CODE MACRO COMMON)
The settings of parameters MV0 to MVA (No.8503#0 to 8504#3) do not match the common
variable data to be input.
Number
Message
Contents
SR2052
#500-#549P-CODE MACRO COMMON SELECT(CANNOT USE SETVN)
The variable name cannot be entered.
The SETVN command cannot be used with the P-CODE macro common variables #500 to
#549.
Number
Message
Contents
SR2053
P-CODE VARIABLE NUMBER IS OUTSIDE OF RANGE
An attempt was made to enter a P-CODE-only variable not existing in the system.
Number
Message
Contents
SR2054
EXTENDED P-CODE VARIABLE NUMBER IS OUTSIDE OF RANGE
An attempt was made to enter an extended P-CODE-only variable not existing in the system.
2.1.4.
Number
Message
Contents
Parameter Writing Alarm (SW Alarm)
SW0100
PARAMETER ENABLE SWITCH ON
The parameter can be set (bit 0 (PWE) of setting parameter No. 8900 = 1).
To set the parameter, turn this parameter ON. Otherwise, set to OFF.
2.1.5.
Servo Alarms (SV Alarm)
Number
Message
SV0001
SYNC ALIGNMENT ERROR
393
Alarm list
B-64805EN/03
Contents
In axis synchronous control, the amount of compensation for synchronization exceeded the
parameter No. 8325 setting value.
This alarm occurs for the master or slave axis.
Number
Message
Contents
SV0002
SYNC EXCESS ERR ALARM 2
In axis synchronous control, the amount of synchronization error exceeded the parameter No.
8332 setting value. When the synchronization is not completed after power-up, the
determination is made by the parameter value No. 8332 multiplied by the parameter No. 8330
multiplier.
This alarm occurs only for the slave axis.
Number
Message
Contents
SV0004
EXCESS ERROR(G31)
The amount of positional deviation during torque limit skip command operation exceeded the
limit value of the parameter No.6287.
Number
Message
Contents
SV0005
SYNC EXCESS ERR (MCN)
In axis synchronous control, for synchronization, the difference value of the machine coordinate
between a master and slave axes exceeded the parameter No. 8314 setting value.
This alarm occurs for the master or slave axis.
Number
Message
Contents
SV0006
ILLEGAL TANDEM AXIS
For the slave axis under tandem control, absolute position detection is set (parameter bit 5
(APC) of parameter No. 1815 = 1).
Number
Message
Contents
SV0007
SV ALM ANOTHER PATH(MULTI AMP.)
When a multi-axis amplifier was used in a multi-path system across paths, a servo alarm
occurred on an axis belonging to another path.
When a system with two or more paths and multiple servo axes between paths are controlled
by a multi-axis amplifier, if a servo alarm occurs on an axis belonging to another path of the
same amplifier, the MCC of the amplifier goes down. Consequently, SV0401 V-READY OFF
occurs on an axis belonging to the local path in the same amplifier. Since SV0401 is caused by
a servo alarm occurred on an axis in another path, SV0007 is caused together to clearly
indicate the fact.
The axis belonging to another path in the same amplifier resolves the cause of the servo alarm.
Number
Message
Contents
SV0010
SV OVERHEAT
Amplifier internal overheat
Number
Message
Contents
SV0011
SV MOTOR OVER CURRENT (SOFTWARE)
The servo control software detected an abnormal command. Possible causes include an
unconnected power cable, cable disconnection (open phase), and short-circuit.
Number
Message
Contents
SV0012
SV DRIVE OFF CIRCUIT FAILURE
The two drive off inputs are not in the same status or a drive off circuit error occurred.
Number
Message
SV0013
SV AMP MCU FAILURE
394
B-64805EN/03
Alarm list
Contents
An error was found in CPU bus data in the amplifier.
Number
Message
Contents
SV0014
SV AMP WATCH DOG (CTRL)
An error occurred in CPU operation in the amplifier.
Number
Message
Contents
SV0015
SV LOW VOLT DRIVER
The driver power supply voltage has dropped in the amplifier.
Possible causes include improper insertion of the control PC board and amplifier failure.
Number
Message
Contents
SV0016
SV CURRENT DETECT ERROR
An error was found in motor current detection data in the amplifier. Possible causes include
improper insertion of the control PC board and amplifier failure.
Number
Message
Contents
SV0017
SV AMP INTERNAL COMMUNICATION FAILURE
An error occurred in serial bus communication in the amplifier. Possible causes include
improper insertion of the control PC board and amplifier failure.
Number
Message
Contents
SV0018
SV AMP ROM DATA FAILURE
An error was found in ROM data in the amplifier.
Number
Message
Contents
SV0019
SV MOTOR OVER CURRENT(GND FAULT)
A ground fault occurred in the motor, power cable, or amplifier.
Number
Message
Contents
SV0021
PS AC INPUT WRONG WIRING
Power supply CX48 is wired incorrectly.
Number
Message
Contents
SV0022
PS INPUT POWER OFF
Input power is not being supplied.
Number
Message
Contents
SV0024
PS SOFT THERMAL
A load higher than the rating was applied.
Number
Message
Contents
SV0025
PS PRE-CHARGE CIRCUIT FAILURE1
Abnormal overheating of the pre-charging circuit inside the PS.
Number
Message
Contents
SV0026
PS PRE-CHARGE CIRCUIT FAILURE2
Abnormal overheating of the pre-charging resistor inside the PS.
Number
Message
SV0027
PS PRE-CHARGE CIRCUIT FAILURE3
395
Alarm list
B-64805EN/03
Contents
An overcurrent was detected during pre-charging.
Number
Message
Contents
SV0031
PS ILLEGAL PARAMETER
An invalid value is set for a PS control parameter.
Number
Message
Contents
SV0032
PS CONTROL AXIS ERROR 1
An invalid value is set in parameter No. 2557. Set parameter APS (No.11549#0) to 1 and
execute automatic setting.
Number
Message
Contents
SV0033
PS CONTROL AXIS ERROR 2
An invalid value is set in parameter No. 2557. Set parameter APS (No.11549#0) to 1 and
execute automatic setting.
Number
Message
Contents
SV0034
PS HARDWARE ERROR
A PS hardware error was detected.
Number
Message
Contents
SV0035
SV NO FAILURE
There is no error with the servo amplifier.
Number
Message
Contents
SV0036
PHASE OPEN
The power line is open.
Number
Message
Contents
SV0037
FAILURE OF SV(OPEN)
An open circuit failure occurred in the servo amplifier output.
Number
Message
Contents
SV0038
SV FAILURE OF CURRENT CTL.
The current detection circuit in the servo amplifier is faulty.
Number
Message
Contents
SV0039
FAILURE OF SV(SHORT)
A short circuit failure occurred in the servo amplifier output.
Number
Message
Contents
SV0040
PS EXTERNAL INPUT COMPONENT ERROR
Failure of PS, PS External input device (AC Reactor, Input filter, or Power supply transformer)
or cable.
Number
Message
Contents
SV0041
PS PFB-R ERROR
PFB-R detected the alarm.
Number
Message
SV0042
PS PFB-C ERROR
396
B-64805EN/03
Alarm list
Contents
PFB-C detected the alarm.
Number
Message
Contents
SV0043
PS SUB MODULE ERROR
Wrong combination or connection of POWER FAILURE BACKUP MODULE.
Number
Message
Contents
SV0046
DIDN'T ARRIVE AT SPECIFIED VALUE(PRESSURE AND POSITION CONTROL)
The specified value was not reached at the end point of the block that specified the pressure
reach check mode (G14.2 P1) or position reach check mode (G14.2 P2) by pressure or
position feedback.
Number
Message
Contents
SV0047
REFERENCE POINT SETTING WITH MECHANICAL STOPPER IS BROKEN OFF
The reference point setting with mechanical stopper is broken off. Set the reference point again
after resetting.
Number
Message
Contents
SV0048
SMART RIGID TAPPING STOP
The excitation of servo motors is turned off because smart rigid tapping is stopped. This alarm
is accompanied by spindle alarm.
Number
Message
Contents
SV0049
SYNC EXCESS ERR (POS DEV)
In pressure/position control mode, the difference in the amount of positional deviation between
the master and slave axes in axis synchronous control exceeded the parameter No. 10416
setting value.
This alarm occurs for the master or slave axis.
Number
Message
Contents
SV0050
CAN NOT CHANGE AXIS SYNCHRONOUS
Illegally switched between synchronous operation and normal operation in axis synchronous
control.
This alarm occurs for the master or slave axis.
Number
Message
Contents
SV0301
APC ALARM: COMMUNICATION ERROR
Since the absolute position detector of the phase A/B caused a communication error, the
correct machine position could not be obtained (data transfer error).
The absolute position detector, cable, or SERVO INTERFACE MODULAR is thought to be
defective.
Number
Message
Contents
SV0302
APC ALARM: OVER TIME ERROR
Since the absolute position detector of the phase A/B caused an overtime error, the correct
machine position could not be obtained (data transfer error).
The absolute position detector, cable, or SERVO INTERFACE MODULAR is thought to be
defective.
Number
Message
Contents
SV0303
APC ALARM: FRAMING ERROR
Since the absolute position detector of the phase A/B caused a framing error, the correct
machine position could not be obtained.
The absolute position detector, cable, or SERVO INTERFACE MODULAR is thought to be
defective.
397
Alarm list
B-64805EN/03
Number
Message
Contents
SV0304
APC ALARM: PARITY ERROR
Since the absolute position detector of the phase A/B caused a parity error, the correct
machine position could not be obtained.
The absolute position detector, cable, or separate detector I/F unit is considered to be
defective.
Number
Message
Contents
SV0305
APC ALARM: PULSE ERROR
Since the absolute position detector of the phase A/B caused a pulse error, the correct
machine position could not be obtained.
The absolute position detector, or cable is thought to be defective.
Number
Message
Contents
SV0306
APC ALARM: OVER FLOW ERROR
Since the amount of positional deviation overflowed, the correct machine position could not be
obtained.
Check parameters Nos. 2084 and 2085.
Number
Message
Contents
SV0307
APC ALARM: MOVEMENT EXCESS ERROR
Since the machine moved excessively, the correct machine position could not be obtained.
Number
Message
Contents
SV0360
ABNORMAL CHECKSUM(INT)
The checksum alarm occurred on the built-in Pulsecoder.
Number
Message
Contents
SV0361
ABNORMAL PHASE DATA(INT)
The phase data abnormal alarm occurred on the built-in Pulsecoder.
Number
Message
Contents
SV0363
ABNORMAL CLOCK(INT)
The clock alarm occurred on the built-in Pulsecoder.
Number
Message
Contents
SV0364
SOFT PHASE ALARM(INT)
A servo control software detected an abnormality on the built-in Pulsecoder.
Number
Message
Contents
SV0365
ABNORMAL ENCODER1(INT)
LED of the built-in Pulsecoder is abnormal.
Number
Message
Contents
SV0366
PULSE MISS(INT)
A pulse error occurred on the built-in Pulsecoder.
Number
Message
Contents
SV0367
COUNT MISS(INT)
A count error occurred on the built-in Pulsecoder.
398
B-64805EN/03
Alarm list
Number
Message
Contents
SV0368
SERIAL DATA ERROR(INT)
The communications data could not be received from the built-in Pulsecoder.
Number
Message
Contents
SV0369
DATA TRANS. ERROR(INT)
A CRC error or stop bit error occurred in the communications data from the built-in Pulsecoder.
Number
Message
Contents
SV0380
ABNORMAL ENCODER1(EXT)
Separate detector error
Number
Message
Contents
SV0381
ABNORMAL PHASE(EXT)
An abnormal alarm in the position data occurred on the separate detector.
Number
Message
Contents
SV0382
COUNT MISS(EXT)
A count error occurred on the separate detector.
Number
Message
Contents
SV0383
PULSE MISS(EXT)
A pulse error occurred on the separate detector.
Number
Message
Contents
SV0384
SOFT PHASE ALARM(EXT)
The servo control software detected abnormal data on the separate detector.
Number
Message
Contents
SV0385
SERIAL DATA ERROR(EXT)
The communications data could not be received from the separate detector.
Number
Message
Contents
SV0386
DATA TRANS. ERROR(EXT)
A CRC error or stop bit error occurred in the communications data from the separate detector.
Number
Message
Contents
SV0387
ABNORMAL ENCODER2(EXT)
Separate detector error
Number
Message
Contents
SV0388
SV BREAK FAILURE
Brake cable, servo amplifier, or servo motor may be faulty.
Number
Message
Contents
SV0401
IMPROPER V_READY OFF
Although the ready signal (PRDY) of the position control was ON, the ready signal (VRDY) of
the velocity control was OFF.
Number
Message
SV0403
CARD/SOFT MISMATCH
399
Alarm list
B-64805EN/03
Contents
The combination of the main board and the servo software is incorrect.
Probable causes are given below.
The correct main board is not attached.
The correct servo software is not installed in flash memory.
Number
Message
Contents
SV0404
IMPROPER V_READY ON
Although the ready signal (PRDY) of the position control was OFF, the ready signal (VRDY) of
the velocity control was ON.
Number
Message
Contents
SV0407
EXCESS ERROR
The difference value of the amount of positional deviation for the synchronization axis
exceeded the setting value (for synchronous control only).
Number
Message
Contents
SV0409
ABNORMAL LOAD TORQUE
An abnormal load was detected on the servo motor, or during Cs axis or spindle positioning.
The alarm can be canceled by RESET.
Number
Message
Contents
SV0410
EXCESS ERROR (STOP)
The amount of positional deviation during stopping exceeded the parameter No. 1829 setting
value.
Number
Message
Contents
SV0411
EXCESS ERROR ( MOVING )
The amount of positional deviation during traveling became excessive than the parameter
setting value.
Number
Message
Contents
SV0413
LSI OVERFLOW
The counter for the amount of positional deviation overflowed
Number
Message
Contents
SV0415
MOTION VALUE OVERFLOW
The velocity exceeding the travel velocity limit was commanded.
Number
Message
Contents
SV0417
ILL DGTL SERVO PARAMETER
A servo parameter setting is incorrect.
When bit 4 of diagnosis data No. 0203 is 1, an illegal parameter was detected by the servo
control software. Identify the cause with reference to diagnosis data No. 0352.
When bit 4 of diagnosis data No. 203 is 0, the CNC software detected an illegal parameter.
This may be due to the following reasons (see diagnosis data No. 0280).
The value specified in parameter No. 2020 as the motor model falls outside the specified
range.
The motor rotation direction in parameter No. 2022 is not set to a correct value (111 or 111).
The speed feedback pulse count per motor rotation in parameter Nos. 2023 and 42296 is
set to a negative or other incorrect value.
The position feedback pulse count per motor rotation in parameter No. 2024 is set to a
negative or other incorrect value.
Number
SV0420
400
B-64805EN/03
Alarm list
Message
Contents
TORQUE DIFFERENCE EXCESS
In axis synchronous control, for synchronization, the difference value of torque between a
master and slave axes exceeded the parameter No. 2031 setting value.
This alarm occurs for a master axis.
Number
Message
Contents
SV0421
EXCESS ERROR (SEMI-FULL)
The difference between the feedback from the semi and full sides exceeded the setting of
parameter No.2118.
Number
Message
Contents
SV0422
OVER SPEED (TRQ CTRL)
In torque control, the commanded permissible velocity was exceeded.
Number
Message
Contents
SV0423
EXCESS ERROR IN TORQUE
In torque control, the total permissible move value specified as a parameter was exceeded.
Number
Message
Contents
SV0430
SV MOTOR OVERHEAT
The servo motor has overheated.
Number
Message
Contents
SV0431
PS OVERLOAD
Overheat When an analog servo adapter is used, the connected unit may have an error.
Number
Message
Contents
SV0432
PS IMPROPER CONTROL VOLTAGE
The control power supply voltage of the PS is abnormal.
Replace the control power supply, cable or PS.
The voltage of the 24V control power supply is abnormal.
Check the voltage and if there is no problem, replace the control power supply, cable or PS.
Action
Number
Message
Contents
SV0433
PS LOW VOLT. DC LINK
Low DC link voltage
Number
Message
Contents
Action
SV0434
SV IMPROPER CONTROL VOLTAGE
The control power supply voltage of the SV is abnormal.
The voltage of the 24V control power supply is abnormal.
Check the voltage and if there is no problem,
replace the control power supply, cable or SV.
Number
Message
Contents
SV0435
SV LOW VOLT DC LINK
Low DC link voltage
Number
Message
Contents
SV0436
SOFTTHERMAL(OVC)
The servo control software detected a software thermal (OVC).
401
Alarm list
B-64805EN/03
Number
Message
Contents
SV0437
PS OVERCURRENT
Overcurrent on input circuit section.
Number
Message
Contents
SV0438
SV OUTPUT OVER CURRENT
Motor overcurrent
Number
Message
Contents
SV0439
PS OVER VOLT. DC LINK
The DC link voltage is too high.
Number
Message
Contents
SV0440
PS EXCESS-REGENERATION2
The amount of regenerative discharge is excessive.
Number
Message
Contents
SV0441
ABNORMAL CURRENT OFFSET
The servo control software detected an abnormality in the motor current detection circuit.
Number
Message
Contents
SV0442
PS PRE-CHARGE FAILURE
The pre-charge circuit for the DC link is abnormal.
Number
Message
Contents
SV0443
SV INTERNAL FAN FAILURE
Internal cooling fan failure.
Number
Message
Contents
SV0444
SV INTERNAL FAN FAILURE
Internal cooling fan failure.
Number
Message
Contents
SV0445
SOFT DISCONNECT ALARM
The servo control software detected a disconnected Pulsecoder.
Number
Message
Contents
SV0447
HARD DISCONNECT(EXT)
The hardware detected a disconnected separate detector.
Number
Message
Contents
SV0448
FEEDBACK DIRECTION MISMATCH
The sign of the feedback signal from the separate detector is opposite to that from the
feedback signal from the built-in Pulsecoder.
Number
Message
Contents
SV0449
SV IPM ALARM
The IPM (Intelligent Power Module) detected an alarm.
Number
Message
SV0453
SPC SOFTWARE DISCONNECTION
402
B-64805EN/03
Alarm list
Contents
Software disconnection alarm of the built-in Pulsecoder.
Turn off the power to the CNC, then remove and insert the Pulsecoder cable. If this alarm is
issued again, replace the Pulsecoder.
Number
Message
Contents
SV0454
ILLEGAL POLE DETECT
The pole position detection function terminated abnormally.
The pole position cannot be detected because the motor did not run.
Number
Message
Contents
SV0455
SERVO SOFTWARE NOT FOUND
The specified servo control software is not found.
The setting value of parameter No. 1024 is incorrect or the required servo software is not
found.
Number
Message
Contents
SV0456
ILLEGAL CURRENT CTRL PERIOD
An attempt was made to set the current loop that could not be set.
The amplifier or pulse module in use do not comply with HIGH SPEED HRV. Or, requirements
to control are not satisfied in the system.
Number
Message
Contents
SV0458
CURRENT CTRL PERIOD MISMATCH
The specified current loop differs from the actual current loop.
Number
Message
Contents
SV0459
HI HRV SETTING ERROR
For two axes whose servo axis numbers (parameter No. 1023) are consecutively even and odd
numbers, HIGH SPEED HRV control is possible for one axis and impossible for the other.
Number
Message
Contents
SV0460
FSSB DISCONNECT
The FSSB connection was discontinued. Possible causes are:
The FSSB connection cable was disconnected or broken.
The amplifier was turned off .
In the amplifier, the low-voltage alarm occurred.
Number
Message
Contents
SV0462
SEND CNC DATA FAILED
The correct data could not be received on a slave side because of the FSSB communication
error.
Number
Message
Contents
SV0463
SEND SLAVE DATA FAILED
The correct data could not be received in the servo software because of the FSSB
communication error.
Number
Message
Contents
SV0465
READ ID DATA FAILED
A read of the ID information for the amplifier has failed at power-on.
Number
Message
SV0466
MOTOR/AMP. COMBINATION
403
Alarm list
B-64805EN/03
Contents
The maximum current of an amplifier is different to that of a motor.
Possible causes are:
The connection command for an amplifier is incorrect.
The parameter No.2165 setting is incorrect
Number
Message
Contents
SV0468
HI HRV SETTING ERROR(AMP)
An attempt was made to set up HIGH SPEED HRV control for use when the controlled axis of
an amplifier for which HIGH SPEED HRV control could not be used.
Number
Message
Contents
SV0476
ILLEGAL SPEED (SV)
For axis n, the servo control software detected that the speed exceeded the setting
(parameters No. 13821 to No. 13824 and No. 41019 to No. 41022 in case of position control, or
No. 13826 to No. 13829 and No. 41023 to No.41026 in case of velocity control) during safety
monitoring (the safety check request signal (*VLDVx) is 0).Keep the safety speed.
Please confirm the safety speed and actual speed on Safe Reduced Speed Check of DCS
screen.
No.13821 to 13824, No.41019 to No.41022 in case of position control
No.13826 to 13829, No.41023 to No.41026 in case of velocity control
Action
Number
Message
Contents
Action
SV0477
ILLEGAL MACHINE POS.(SV)
For axis n, the servo control software detected that the machine position fell outside the safety
area (setting by parameters Nos. 13831 to 13838) during safety monitoring (when safety
monitoring request signal *VLDVx is 0). Drive within the safety area.
A machine position check is performed only on the axis for which the reference position has
been established. The axis for which the reference position is not established is not subjected
to a machine position check.
Please confirm the safety position and machine position on Safe Machine Position Monitoring
of DCS screen.
The safety machine position is set by parameters (No.13831 to 13838, No.41011 to No.41018).
Number
Message
Contents
SV0478
ILLEGAL AXIS DATA (SV)
For axis n, the servo control software detected that an error occurred during transfer of axis
data.
When an alarm occurred because the configuration of the servo amplifier was changed, set the
axis number for the servo amplifier (set bit 4 of parameter No. 2212 of the corresponding axis
to 1 and 0 again and turn off the power of the entire system). When using a multi-axis amplifier,
this operation may not clear the alarm. In this case, repeat this operation for the axes on which
the alarm persists.
If an alarm occurs due to a cause other than the above, replace the servo amplifier.
Number
Message
Contents
Action
SV0481
SAFETY PARAM ERROR (SV)
Error detected for safety parameter check function by the servo control software for axis n.
Re-input the safety parameters.
Number
Message
Contents
SV0488
SELF TEST OVER TIME
An MCC off test was not complete within the set period of time (parameter No. 1946).Check
the MCC contact.
Number
Message
SV0490
SAFETY FUNCTION ERROR(DCS_S1)
404
B-64805EN/03
Alarm list
Contents
A DCS_S1 safety function error occurred in the n-axis.
The servo control software detected that the safety function was not executed in the CNC.
The result of a CNC safety function check did not match the result of a servo motor safety
function check.
Number
Message
Contents
SV0494
ILLEGAL SPEED (DCS_S1)
For axis n, the DCS_S1 detected that the specified speed exceeded the setting (parameter No.
13821 to No. 13824 and No. 41019 to No. 41022 in case of position control, or No. 13826 to
No. 13829 and No. 41023 to No. 41026 in case of velocity control) during safety monitoring
(the safety check request signal (*VLDVx) is 0).Keep the safety speed.
Please confirm the safety speed and actual speed on Safe Reduced Speed Check of DCS
screen.
No.13821 to 13824, No.41019 to No.41022 in case of position control
No.13826 to 13829, No.41023 to No.41026 in case of velocity control
Action
Number
Message
Contents
SV0495
ILLEGAL MACHINE POS.(DCS_S1)
The DCS_S1 detected that the machine position on the axis is not in the safety area
(parameter Nos. 13831 to 13838 and Nos. 41011 to 41018) during safety monitoring (the
safety check request signal (*VLDVx) is 0) in the n-th axis. Keep the safety area.
A machine position check is performed only on the axis for which the safety position has been
established.
Number
Message
Contents
SV0496
ILLEGAL AXIS DATA(CNC)
The CNC detected that an error occurred during transfer to axis data.
When an alarm occurred because the configuration of the servo amplifier was changed, set the
axis number for the servo amplifier (set bit 4 of parameter No. 2212 of the corresponding axis
to 1 and 0 again and turn off the power of the entire system). When using a multi-axis amplifier,
this operation may not clear the alarm. In this case, repeat this operation for the axes on which
the alarm persists.
If an alarm occurs due to a cause other than the above, replace the servo amplifier.
Number
Message
Contents
SV0498
AXIS NUMBER NOT SET(CNC)
CNC detected that the axis number of axis n is not set in the servo amplifier.The axis numbers
are set automatically and the entire system should be turned off.
Number
Message
Contents
SV0600
SV DC LINK OVER CURRENT
DC link overcurrent.
Number
Message
Contents
SV0601
SV EXTERNAL FAN FAILURE
Radiator cooling fan failure.
Number
Message
Contents
SV0602
SV RADIATOR OVERHEAT
The servo amplifier radiator has overheated.
Number
Message
Contents
SV0603
SV IPM ALARM(OH)
The IPM (Intelligent Power Module) detected an overheat alarm.
405
Alarm list
B-64805EN/03
Number
Message
Contents
SV0604
AMP COMMUNICATION ERROR
The communication between Servo Amplifier (SV) and Common Power Supply (PS) is in error.
Number
Message
Contents
SV0605
PS EXCESS-REGENERATION1
The motor regenerative power is excessive.
Number
Message
Contents
SV0606
PS EXTERNAL FAN FAILURE
External radiator cooling fan failure.
Number
Message
Contents
SV0607
PS IMPROPER INPUT POWER
Input power supply fault
Number
Message
Contents
SV0642
OVER PRESSURE
The pressure feedback value exceeded the allowed value.
Number
Message
Contents
SV0643
TOO SMALL PRESSURE COMMAND
The pressure command value is too small.
Number
Message
Contents
SV0644
IMPROPER INITIAL PRESSURE
Initial pressure is not proper.
Number
Message
Contents
SV0645
EXCESS ERROR (CHANGING INTO POS. CTRL)
The amount of positional deviation when switching from pressure control to position control is
larger than the setting value.
Number
Message
Contents
SV0646
ABNORMAL ANALOG SIGNAL(EXT)
An error occurred in the analog 1Vp-p output of the separate detector.
The separate detector, cable, or separate detector I/F unit is considered to be defective.
Number
Message
Contents
SV0649
MOTOR OVER SPEED
Motor speed exceeded the allowable speed on n-axis.
Number
Message
Contents
SV0652
TEMP. ERROR
Communication between the separate detector interface unit and temperature sensor was
disconnected.
Number
Message
Contents
SV0653
EXCESS ERROR(SV)
The difference between the estimated positional deviation and the actual positional deviation
exceeded the value set in parameter (No.2458).
406
B-64805EN/03
Alarm list
Number
Message
Contents
SV0654
DB RELAY FAILURE
A failure occurs in the dynamic brake relay of the servo amplifier. Replace the amplifier or the
dynamic brake module.
Number
Message
Contents
SV0659
ILLEGAL SSM SETTING
Setting parameters of SSM are not correct.
This alarm may occur in the following case:
The servo amplifier does not support SSM.
Number
Message
Contents
SV1025
V_READY ON (INITIALIZING )
The ready signal (VRDY) of the velocity control which should be OFF is ON while the servo
control is ON.
Number
Message
Contents
SV1026
ILLEGAL AXIS ARRANGE
The parameter for servo motor axis arrange is not set correctly.
Parameter No. 1023 (servo axis number of each axis) is set to a negative value or a
duplicate value.
The settings for parameter No. 1023 (servo axis number of each axis) were made with a
certain setting skipped among 1 to 18, 19 to 36, 37 to 54 or 55 to 72.
Number
Message
Contents
SV1051
ILLEGAL SYNCHRONOUS AXIS
The parameter setting of the axis using a linear scale with an absolute address reference mark
during axis synchronous control is illegal. For the following parameters, set the same value for
the master and slave axes.
Parameter No. 1821 (mark 1 interval)
Parameter No. 1882 (mark 2 interval)
Bits 2 and 1 (DC2x, DC4x) of parameter No. 1802 (number of marks to detect)
Number
Message
Contents
SV1055
ILLEGAL TANDEM AXIS
In tandem control, the setting of the parameter No. 1023 is incorrect.
In tandem control, the setting of the bit 6 (TDM) of parameter No. 1817 is incorrect.
Number
Message
Contents
SV1067
FSSB:CONFIGURATION ERROR(SOFT)
An FSSB configuration error occurred (detected by software).
The connecting amplifier type is incompatible with the FSSB setting value.
Number
Message
Contents
SV1068
DUAL CHECK SAFETY ALARM
The alarm which shut off the entire system occurred in the dual check safety function.
Number
Message
Contents
SV1073
SAFETY SPEED ZERO ERROR(DCS_S1)
The DCS_S1 detected that the n-th axis position exceeded the safety speed zero monitoring
width (parameter No.13844).
Number
Message
SV1074
SAFETY SPEED ZERO ERROR(SV)
407
Alarm list
B-64805EN/03
Contents
For axis n, the servo control software detected that the axis position has moved outside the
range of the safety speed zero monitoring width (parameter No. 13844).
Number
Message
Contents
SV1075
ILLEGAL SPEED (DETACH:DCS_S1)
In the detached axis, the DCS_S1 detected that the specified speed exceeded the setting
(parameter No.13821 to No.13824 and No.41019 to No.41022 in case of position control,
No.13826 to No.13829 and No.41023 to No.41026 in case of velocity control) during safety
monitoring (the safety check request signal (*VLDVx) is 0).
Number
Message
Contents
SV1076
ILLEGAL SPEED (DETACH:SV)
For the axis being detached, the servo control software detected that the speed exceeded the
setting (parameter No. 13821 to No. 13824 and No. 41019 to No. 41022 in case of position
control, or No. 13826 to No. 13829 and No. 41023 to No. 41026 in case of velocity control)
during safety monitoring (the safety check request signal (*VLDVx) is 0).
Number
Message
Contents
SV1093
AXIS STOP(INTERFERENCE CHECK)
The feed axis was stopped immediately because interference was detected in the CNCintegrated 3-dimensional interference check.
Number
Message
Contents
SV1094
STOP DISTANCE REDUCTION ENABLE
An axis stop was executed with the power failure quick stop function.
Number
Message
Contents
SV1100
S-COMP. VALUE OVERFLOW
The straightness compensation amount exceeded the maximum value of 32767.
Number
Message
Contents
SV5134
FSSB:OPEN READY TIME OUT
In the initialization, the FSSB could not be in an open ready sate. The main board may be
faulty.
Number
Message
Contents
SV5137
FSSB:CONFIGURATION ERROR
An FSSB configuration error occurred.
The connecting amplifier type is incompatible with the FSSB setting value.
Number
Message
Contents
SV5139
FSSB:ERROR
Servo motor initialization has not completed successfully. It is probable that an optical cable
failed or a connection between the amplifier and another module failed.
Number
Message
Contents
SV5197
FSSB:OPEN TIME OUT
The initialization of the FSSB was completed, but it could not be opened.
Or, the connection between the CNC and the amplifier in is incorrect.
Number
Message
Contents
SV10000
SERVO COMMUNICATION TIME OUT(1)
Communication with the servo software has timed out.
408
B-64805EN/03
Alarm list
Number
Message
Contents
SV10001
SERVO COMMUNICATION TIME OUT(2)
Communication with the servo software has timed out.
Number
Message
Contents
SV10002
SERVO COMMUNICATION TIME OUT(3)
Communication with the servo software has timed out.
Number
Message
Contents
SV10003
SERVO COMMUNICATION TIME OUT(4)
Communication with the servo software has timed out.
Number
Message
Contents
SV10004
SERVO COMMUNICATION TIME OUT(5)
Communication with the servo software has timed out.
Number
Message
Contents
SV10005
SERVO COMMUNICATION ERROR(1)
An error occurred in communication with the servo software.
Number
Message
Contents
SV10006
SERVO COMMUNICATION ERROR(2)
An error occurred in communication with the servo software.
Number
Message
Contents
SV10007
SERVO CONTROL HARDWARE ERROR(1)
An error has occurred in the hardware for servo control.
Number
Message
Contents
SV10008
SERVO CONTROL HARDWARE ERROR(2)
An error has occurred in the hardware for servo control.
Number
Message
Contents
SV10009
SERVO SOFT ERROR(1)
An error occurred in the servo software.
Number
Message
Contents
SV10010
NUMBER OF AXES OVER(HRV2)
The number of axes controllable by the HRV2 setting has been exceeded. Please check the
setting of No.1023.
Action
Servo axis No.1023 exceeds the maximum number of controlled axes in the servo axis group
.
Please check the setting of No.1023.
Number
Message
Contents
SV10011
NUMBER OF AXES OVER(HRV3)
The number of axes controllable by the HRV3 setting has been exceeded. Please check the
setting of No.1023.
Servo axis No.1023 exceeds the maximum number of controlled axes in the servo axis group
.
Action
409
Alarm list
B-64805EN/03
Please check the setting of No.1023.
Number
Message
Contents
Action
SV10012
NUMBER OF AXES OVER(HRV4)
The number of axes controllable by the HRV4 setting has been exceeded. Please check the
setting of No.1023.
Servo axis No.1023 exceeds the maximum number of controlled axes in the servo axis group
.
Please check the setting of No.1023.
Number
Message
Contents
SV10100
INEXECUTION OF SAFETY FUNCTIONS (SV)
The DCS_S1 detected abnormal condition in the execution of servo safety functions.
Number
Message
Contents
SV10109
SV SAFETY COMMUNICATION ERROR(DCS_S1)
DCS_S1 detected a communication error between DCS_S1 and servo control software.
Number
Message
Contents
SV10110
SV SAFETY COMMUNICATION ERROR(DCS_S2)
DCS_S2 detected a communication error between DCS_S2 and servo control software.
Number
Message
Contents
SV10115
SAFETY POSITION ERROR MONITORING ERROR(DCS_S1)
The DCS_S1 detected that the positional deviation exceeded in the n-th axis.
Number
Message
Contents
SV10116
SAFETY POSITION ERROR MONITORING ERROR (SV)
The servo control software detected that the positional deviation exceeded in the n-th axis.
Number
Message
Contents
SV10117
CROSS CHECK ERROR BETWEEN DCS_S1 AND SV_SOFT(DCS_S1)
DCS_S1 detected that the safety function check results between DCS_S1 and servo control
software did not match.
Number
Message
Contents
SV10118
CROSS CHECK ERROR BETWEEN DCS_S1 AND SV_SOFT (SV)
Servo control software detected that the safety function check results between DCS_S1 and
servo control software did not match.
Number
Message
Contents
SV10120
POSITION FEEDBACK DATA ERROR(DCS)
The difference between the position feedback data of the two systems has exceeded a certain
value. (Detected by DCS)
Number
Message
Contents
SV10121
FSSB COMMUNICATION ERROR BETWEEN DCS_S1 AND SV AMP
A data error was detected in the FSSB communication between DCS_S1 and the servo
amplifier.
Number
Message
SV10123
DCS_S1 SAFETY COMMUNICATION ERROR (SV)
410
B-64805EN/03
Alarm list
Contents
The servo control software detected a communication error between servo control software
and DCS_S1.
Number
Message
Contents
SV10124
DCS_S2 SAFETY COMMUNICATION ERROR (SV)
The servo control software detected a communication error between servo control software
and DCS_S2.
Number
Message
Contents
SV10125
INEXECUTION OF SAFETY FUNCTIONS (SV)
The servo control software detected abnormal condition in the execution of safety functions.
Number
Message
Contents
SV10126
POSITION FEEDBACK DATA ERROR (SV)
The difference between the position feedback data of the two systems has exceeded a certain
value. (Detected by servo control software)
Number
Message
Contents
SV10127
FSSB COMMUNICATION ERROR BETWEEN SV SOFTWARE AND SV AMP
The servo control Software detected FSSB communication error on the servo amplifier.
Number
Message
Contents
SV10128
SAFETY SPEED ERROR MONITORING ERROR(DCS_S1)
The DCS_S1 detected the speed deviation between velocity command and feedback has
exceeded the specified value.
Number
Message
Contents
SV10129
SAFETY SPEED ERROR MONITORING ERROR (SV)
The servo control software detected the speed deviation between velocity command and
feedback has exceeded the specified value.
Number
Message
Contents
SV10130
SAFETY ERROR MONITORING IS DISABLED (DCS_S1)
The DCS_S1 detected safety position error monitoring and safety speed error monitoring are
both disabled.
Number
Message
Contents
SV10131
SAFETY ERROR MONITORING IS DISABLED (SV)
The servo control software detected safety position error monitoring and safety speed error
monitoring are both disabled.
Number
Message
Contents
SV10132
STO STATUS CHECK ERROR(DCS1)
Abnormality detected in STO status check. (DCS1)
Number
Message
Contents
SV10133
STO STATUS CHECK ERROR(DCS2)
Abnormality detected in STO status check. (DCS2)
Number
Message
SV10136
SAFETY POSITION SWITCH CROSS CHECK ERROR BETWEEN DCS_S1 AND
DCS_S2(DCS_S1)
411
Alarm list
B-64805EN/03
Contents
DCS_S1 detected that the safety position switch check results between DCS_S1 and DCS_S2
did not match.
Number
Message
SV10137
SAFETY POSITION SWITCH CROSS CHECK ERROR BETWEEN DCS_S1 AND
DCS_S2(DCS_S2)
DCS_S2 detected that the safety position switch check results between DCS_S1 and DCS_S2
did not match.
Contents
Number
Message
Contents
2.1.6.
SV10138
FSSB SAFETY COMMUNICATION ERROR (SV)
The SV amplifier detected an anomaly in the FSSB safety communication.
Overtravel Alarms (OT Alarm)
Number
Message
Contents
OT0500
+ OVERTRAVEL(SOFT 1)
Exceeded the + side stored stroke check 1.
Number
Message
Contents
OT0501
- OVERTRAVEL(SOFT 1)
Exceeded the - side stored stroke check 1.
Number
Message
Contents
OT0502
+ OVERTRAVEL(SOFT 2)
Exceeded the + side stored stroke check 2. Or, in the chuck and tail stock barrier, an entry to
the inhibited area was made during movement in the positive direction.
Number
Message
Contents
OT0503
- OVERTRAVEL(SOFT 2)
Exceeded the - side stored stroke check 2. Or, in the chuck and tail stock barrier, an entry to
the inhibited area was made during movement in the negative direction.
Number
Message
Contents
OT0504
+ OVERTRAVEL(SOFT 3)
Exceeded the + side stored stroke check 3.
Number
Message
Contents
OT0505
- OVERTRAVEL(SOFT 3)
Exceeded the - side stored stroke check 3.
Number
Message
Contents
OT0506
+ OVERTRAVEL(HARD)
The stroke limit switch in the positive direction was triggered.
This alarm is generated when the machine reaches the stroke end. When this alarm is
generated, feed of all axes in the path is stopped during automatic operation. During manual
operation, only the feed of the axis on which the alarm occurred is stopped.
Number
Message
Contents
OT0507
- OVERTRAVEL(HARD)
The stroke limit switch in the negative direction was triggered.
412
B-64805EN/03
Alarm list
This alarm is generated when the machine reaches the stroke end. When this alarm is
generated, feed of all axes in the path is stopped during automatic operation. During manual
operation, only the feed of the axis on which the alarm occurred is stopped.
Number
Message
Contents
OT0508
INTERFERENCE:+
A tool moving in the positive direction along the n axis has fouled another tool post.
Number
Message
Contents
OT0509
INTERFERENCE:A tool moving in the negative direction along the n axis has fouled another tool post.
Number
Message
Contents
OT0510
+ OVERTRAVEL(PRE-CHECK)
The tool exceeded the limit in the positive direction during the stroke limit check before move.
Modify the program.
Number
Message
Contents
OT0511
- OVERTRAVEL(PRE-CHECK)
The tool exceeded the limit in the negative direction during the stroke limit check before move.
Modify the program.
Number
Message
Contents
OT0514
(n) INTERFERENCE:+
An interference occurred on the positive side of the n-axis in the interference check for rotary
area.
Number
Message
Contents
OT0515
(n) INTERFERENCE:An interference occurred on the negative side of the n-axis in the interference check for rotary
area.
Number
Message
Contents
OT0518
(n)+: INTERFERE([Target name 1],[Target name 2])
A check made for interference between [Target name1] and [Target name2] detected
interference on the positive side of axis n. n represents the name of the axis with which an
alarm is issued.
Number
Message
Contents
OT0519
(n)-: INTERFERE ([Target name 1],[ Target name 2])
A check made for interference between [Target name1] and [Target name2] detected
interference on the negative side of axis n. n represents the name of the axis with which an
alarm is issued.
Number
Message
Contents
OT0520
+ OVERTRAVEL(CHUCK TAIL BARRIER)
Or, in the chuck and tail stock barrier, an entry to the inhibited area was made during
movement in the positive direction.
Number
Message
Contents
OT0521
- OVERTRAVEL(CHUCK TAIL BARRIER)
In the chuck and tail stock barrier, an entry to the inhibited area was made during movement in
the negative direction.
413
Alarm list
B-64805EN/03
Number
Message
Contents
OT0522
+ MOVE INTO PROHIBITED AREA
Moved into the prohibited area on the + side specified by parameter Nos. 1362 and 1363.
Number
Message
Contents
OT0523
- MOVE INTO PROHIBITED AREA
Moved into the prohibited area on the - side specified by parameter Nos. 1362 and 1363.
Number
Message
Contents
OT1710
ILLEGAL ACC. PARAMETER(OPTIMUM TORQUE ACC/DEC)
There are errors in the parameters of permissible acceleration for Optimum Torque
Acceleration/Deceleration. The possible causes are:
The ratio of the acceleration for deceleration to the acceleration for the acceleration is
lower than the limited value.
The time required to slow down to a speed of 0 exceeds the maximum.
2.1.7.
Memory File Alarms (IO Alarm)
Number
Message
Contents
IO1001
FILE ACCESS ERROR
The resident-type file system could not be accessed as an error occurred in the resident-type
file system.
Number
Message
Contents
IO1002
FILE SYSTEM ERROR
The file could not be accessed as an error occurred in the CNC file system.
Number
Message
Contents
IO1030
CHECK SUM ERROR
The checksum of the CNC part program storage memory is incorrect.
Number
Message
Contents
IO1032
MEMORY ACCESS OVER RANGE
Accessing of data occurred outside the CNC part program storage memory range.
Number
Message
Contents
IO1034
PROG-FOLDER FILE IS BROKEN
Abnormality of data was detected in the program folder file. It is necessary to initialize the
program file to recover.
Number
Message
Contents
IO1035
PROG-MANAGEMENT FILE IS BROKEN
Abnormality of data was detected in the program management file. It is necessary to initialize
the program file to recover.
Number
Message
Contents
IO1104
OVER MAXIMUM TOOL LIFE PAIRS
The maximum number of tool life management pairs is exceeded. Modify the setting of the
maximum number of tool life management pairs in parameter No. 6813.
414
B-64805EN/03
2.1.8.
Alarm list
Alarms Requiring Power To Be Turned Off (PW Alarm)
Number
Message
Contents
PW0000
POWER MUST BE OFF
A parameter was set for which the power must be turned OFF then ON again.
Number
Message
Contents
PW0001
X-ADDRESS(*DEC) IS NOT ASSIGNED.
The X address of PMC could not be assigned correctly.
Possible causes are:
During the setting of parameter No. 3013, the X address could not be assigned correctly
for the deceleration dog (*DEC) for reference position return.
If there are four or more paths or there are nine or more axes for every one path, signals
need to be assigned via setting bit 2 (XSG) of parameter No. 3008 and parameters No.
3013 and 3014.
Number
Message
Contents
PW0002
PMC address is not correct(AXIS).
The address to assign the axis signal is incorrect. Possible causes are:
The setting for parameter No. 3025 is incorrect.
Number
Message
Contents
PW0003
PMC address is not correct(SPINDLE).
The address to assign the spindle signal is incorrect. Possible causes are:
The setting for parameter No. 3026 is incorrect.
Number
Message
Contents
PW0006
POWER MUST BE OFF (ILL-EXEC-CHK)
The malfunction prevent function detected an alarm to require the power off.
Number
Message
Contents
PW0007
X-ADDRESS(SKIP) IS NOT ASSIGNED
The X address of PMC could not be assigned correctly.
Possible causes are:
During the set of parameter No. 3012, the skip signal of the X address was not assigned
correctly.
During the set of parameter No. 3019, the address other than the skip signal of the X
address was not assigned correctly.
Number
Message
Contents
PW0010
SAFE I/O CROSS CHECK ERROR(DCSPMC1)
The I/O cross-check function of DCSPMC1 detected the discrepancy in a system-defined
safety related I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
PW0011
SAFE I/O CROSS CHECK ERROR(DCSPMC2)
The I/O cross-check function of DCSPMC2 detected the discrepancy in a system-defined
safety related I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
PW0012
USER I/O CROSS CHECK ERROR(DCSPMC1)
The I/O cross-check function of DCSPMC1 detected the discrepancy in a programmable safe
I/O signal.
415
Alarm list
B-64805EN/03
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
PW0013
USER I/O CROSS CHECK ERROR(DCSPMC2)
The I/O cross-check function of DCSPMC2 detected the discrepancy in a programmable safe
I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
PW0014
CPU SELF TEST ERROR(DCS_S1)
An error occurred in a DCS_S1 CPU Self-Test function.
Number
Message
Contents
PW0016
RAM SELF TEST ERROR (DCS_S1)
The DCS_S1 detected error in RAM Self-Test function.
Number
Message
Contents
PW0017
INEXECUTION OF SAFETY FUNCTIONS(DCS_S1)
The DCS_S1 detected abnormal condition in the execution of DCS_S1 safety functions.
Number
Message
Contents
PW0018
ROM SELF TEST ERROR(DCS_S1)
The DCS_S1 detected the ROM Self-Test error.
Number
Message
Contents
PW0020
HSP PARAMETER ERROR(MPATH)
The total value specified for all paths in parameter No. 11604 exceeds 600 (1000).
Number
Message
Contents
PW0024
CPU SELF TEST ERROR(DCS_S2)
An error occurred in a DCS_S2 CPU Self-Test.
Number
Message
Contents
PW0028
RAM SELF TEST ERROR (DCS_S2)
The DCS_S2 detected error in RAM Self-Test function.
Number
Message
Contents
PW0031
ITP SYSTEM ERROR(DCS_S1)
DCS_S1 detected a critical error in ITP.
Number
Message
Contents
PW0032
ROM SELF TEST ERROR(DCS_S2)
The DCS_S2 detected the ROM Self-Test error.
Number
Message
Contents
PW0033
ITP SYSTEM ERROR(DCS_S1)
DCS_S2 detected a critical error in ITP.
Number
Message
PW0036
ILLEGAL SETTING FOR SERVO MOTOR SPINDLE
416
B-64805EN/03
Alarm list
Contents
The parameter setting for the servo axes for spindle use of the spindle control with servo motor
is illegal.
The servo axes number for spindle use has exceeded 4 axes.
Servo axes number for spindle use are fewer than the axes number of designation of
servo axes for spindle use.
The servo axes for spindle use is not set as a spindle control with servo motor axis.
The servo axes for spindle use is not set as a rotation axis.
The servo axis number (parameter No.1023) is a negative value.
Number
Message
Contents
PW0037
SV/SP COMBINATION ERROR
The servo axis might be a setting of the dummy axis.
Check to see the parameter (No.1023), DMYx (No.2009#0), and KSVx (No.11802#4).
The index number of spindle axis that synchronizes servo axis might be illegal. Check to
see the parameter A/Ss No.3716#0, No.3717, and No.24204.
Number
Message
Contents
PW0041
DATA TABLE(D)SETTING IS ILLEGAL
The address of the PMC data table (D) calculated from parameter No. 1313, the stored
stroke limit range switching data selection signal (OTD0 to OTD15), and the switching
data area is illegal.
The specified start address is illegal.
Not a multiple of 4.
The range of the specified data table is illegal.
The address of the PMC data table (D) set by parameters No. 25694 and 25695 is invalid.
Number
Message
Contents
PW0053
SP-MODE CHANGE SETTING ERROR
Setting of parameter Nos. 25800 to 25806 is invalid. Causes of the alarm are as follows.
A value outside the allowable range is set.
The same value is set when spindle selection by address P is not used.
The same value is not set to all spindles when spindle selection by address P is used.
The value except for 0 is set when the spindle orientation or Cs contouring control function
is not available.
One of M code of spindle orientation ON/OFF is set.
One of M code of Cs contouring control ON/OFF is set.
Number
Message
Contents
PW0060
PS CONTROL AXIS ERROR 3
Amplifier group number duplication. Set parameter APS (No.11549#0) to 1 and execute
automatic setting.
Number
Message
Contents
PW0070
ILLEGAL SETTING OF SV LEARNING
A function that cannot be used together with servo learning oscillation was set for the
oscillation axis.
High precision learning control A (No.2019#5)
High precision learning control B (No.2019#6)
High precision learning control C (No.2019#2)
Learning control for parts cutting A (No.2227#0)
Learning control for parts cutting B (No.2019#0)
Learning helical interpolation (No.2439#0)
Number
Message
Contents
PW0071
ILLEGAL SETTING OF OSCILLATION
Bit 1 (SVOSCIx) of parameter No. 2439 was set to 1 for an axis to which servo learning
oscillation cannot be applied.
Cs axis
417
Alarm list
B-64805EN/03
Spindle positioning axis
Dummy axis (bit 0 (DMY) of parameter No. 2009 is set to 1, bit 4 (KSV) of parameter No.
11802 is set to 1)
Number
Message
Contents
PW1104
ILLEGAL PARAMETER(3-D MACHINE POSITION COMPENSATION.)
The setting of the 3-dimensional machine position compensation parameter is incorrect.
Number
Message
Description
PW1106
ILLEGAL PARAMETER (EXECUTION MACRO)
The axis number setting (parameter No. 9076) for the execution macro is incorrect.
Number
Message
Contents
PW4549
ILLEGAL TOOL DATA FORMAT
The size of the registered tool data patterns has exceeded the upper limit of 32KB.
Number
Message
Description
PW5046
ILLEGAL PARAMETER (S-COMP.)
The setting of a parameter related to straightness compensation contains an error. Causes of
the alarm include the following.
The number of pitch error compensation points between the most negative side and most
positive side has exceeded 1536.
The setting of the compensation point number for interpolation type straightness
compensation is 6000 or lower. (Parameters No. 13381 to 13390, 5795, 5796)
Number
Message
Contents
PW5390
R-ADDRESS SETTING IS ILLEGAL
The start address or the set range of the PMC R addresses set by parameters Nos. 3773,
13541 and 13542 is invalid.
Number
Message
Contents
PW10100
SAFETY PARAM ERROR(DCS_S1)
The DCS_S1 detected an error for safety parameter check function.
Number
Message
Contents
PW10101
SAFETY PARAM ERROR(DCS_S2)
The DCS_S2 detected an error for safety parameter check function.
Number
Message
Contents
PW10102
DCS OPTION ERROR
The CNC detected that the Dual Check Safety function is enabled while the Dual Check Safety
option is disabled.
Number
Message
Contents
PW10103
SOFTWARE COMBINATION ERROR(SAFETY AND OTHER)
The combination of safety software and other software is incorrect.
Number
Message
Contents
PW10104
FSSB SAFETY COMMUNICATION ERROR(HARD)
Hardware detected that the safety communication error on FSSB.
Number
Message
PW10105
CROSS CHECK ERROR BETWEEN DCS_S1 AND DCS_S2(DCS_S1)
418
B-64805EN/03
Alarm list
Contents
DCS_S1 detected that the safety function check results between DCS_S1 and DCS_S2 did not
match.
Number
Message
Contents
PW10106
CROSS CHECK ERROR BETWEEN DCS_S1 AND DCS_S2(DCS_S2)
DCS_S2 detected that the safety function check results between DCS_S1 and DCS_S2 did not
match.
Number
Message
Contents
PW10108
DCS SAFETY COMMUNICATION ERROR(DCS_S2)
DCS_S2 detected a communication error between DCS_S1 and DCS_S2.
Number
Message
Contents
PW10109
DCS SAFETY COMMUNICATION ERROR(DCS_S1)
DCS_S1 detected a communication error between DCS_S1 and DCS_S2.
Number
Message
Contents
PW10110
DCS SOFTWARE VERSION ERROR
DCS Software Version Error is detected.
Number
Message
Contents
PW10111
SAFETY SIGNAL CHANNEL CONFIGURATION ERROR
The value of No.41030 or 41031 is invalid.
Number
Message
Contents
PW10112
IPL CRITICAL ERROR(DCS_S1)
DCS_S1 detected a critical error in IPL.
Number
Message
Contents
PW10113
IPL CRITICAL ERROR(DCS_S2)
DCS_S2 detected a critical error in IPL.
Number
Message
Contents
PW10114
ITP CRITICAL ERROR(DCS_S1)
DCS_S1 detected a critical error in ITP.
Number
Message
Contents
PW10115
ITP CRITICAL ERROR(DCS_S2)
DCS_S2 detected a critical error in ITP.
Number
Message
Contents
PW10116
VOLTAGE MONITORING ERROR
Voltage monitoring function detected an error.
Number
Message
Contents
PW10119
INEXECUTION OF SAFETY FUNCTIONS(DCS_S2)
The DCS_S2 detected abnormal condition in the execution of DCS_S2 safety functions.
Number
Message
Contents
PW10120
INEXECUTION OF SAFETY FUNCTIONS(DCS_S1)
The DCS_S2 detected abnormal condition in the execution of DCS_S1 safety functions.
419
Alarm list
B-64805EN/03
Number
Message
Contents
PW10121
INEXECUTION OF SAFETY FUNCTIONS(DCS_S2)
The DCS_S1 detected abnormal condition in the execution of DCS_S2 safety functions.
Number
Message
Contents
PW10140
CPU SELF TEST ERROR (SV)
An error occurred in a Servo CPU Self-Test.
Number
Message
Contents
PW10141
ROM SELF TEST ERROR (SV)
The servo control software detected the ROM Self-Test error.
Number
Message
Contents
PW10142
RAM SELF TEST ERROR (SV)
The servo control software detected error in RAM Self-Test function.
Number
Message
Contents
PW10160
VARIABLE INITIAL DATA FOR DCS DIFFERS FROM THE REGISTERED DATA(DCSPMC1)
The DCSPMC1 detected that the loaded variable initialization data is different from the
registered data.
Number
Message
Contents
PW10161
VARIABLE INITIAL DATA FOR DCS DIFFERS FROM THE REGISTERED DATA(DCSPMC2)
The DCSPMC2 detected that the loaded variable initialization data is different from the
registered data.
Number
Message
Contents
PW10170
DCS TRANSFER ERROR(DCSPMC1)
The DCSPMC1 detected the communication error between DCSPMC1 and DCSPMC2.
Number
Message
Contents
PW10171
DCS TRANSFER ERROR(DCSPMC2)
The DCSPMC2 detected the communication error between DCSPMC1 and DCSPMC2.
Number
Message
Contents
PW10172
FLOW MONITORING ERROR(DCSPMC1)
The DCSPMC1 detected abnormal condition in the execution of the safety functions.
Number
Message
Contents
PW10173
FLOW MONITORING ERROR(DCSPMC2)
The DCSPMC2 detected abnormal condition in the execution of the safety functions.
Number
Message
Contents
PW10174
FLOW MONITORING CROSS CHECK ERROR(DCSPMC1)
The DCSPMC1 detected abnormal condition in the execution of DCSPMC2 safety functions.
Number
Message
Contents
PW10175
FLOW MONITORING CROSS CHECK ERROR(DCSPMC2)
The DCSPMC2 detected abnormal condition in the execution of DCSPMC1 safety functions.
420
B-64805EN/03
Alarm list
Number
Message
Contents
PW10176
SAFETY PARAM SETTING ERROR(DCSPMC1)
The DCSPMC1 detected an error in safety parameter.
Number
Message
Contents
PW10177
SAFETY PARAM SETTING ERROR(DCSPMC2)
The DCSPMC2 detected an error in safety parameter.
Number
Message
Contents
PW10178
PROGRAM FOR DCS CRC ERROR(DCSPMC1)
The DCSPMC1 detected that the CRC of the sequence program is invalid.
Number
Message
Contents
PW10179
PROGRAM FOR DCS CRC ERROR(DCSPMC2)
The DCSPMC2 detected that the CRC of the sequence program is invalid.
Number
Message
Contents
PW10180
PROGRAM FOR DCS DIFFERS FROM REGISTERED PROGRAM(DCSPMC1)
The DCSPMC1 detected that the loaded sequence program is different from the registered
sequence program.
Number
Message
Contents
PW10181
PROGRAM FOR DCS DIFFERS FROM REGISTERED PROGRAM(DCSPMC2)
The DCSPMC2 detected that the loaded sequence program is different from the registered
sequence program.
Number
Message
Contents
PW10182
VARIABLE INITIAL DATA FOR DCS CRC ERROR(DCSPMC1)
The DCSPMC1 detected that the CRC of the variable number initialization data for DCS is
invalid.
Number
Message
Contents
PW10183
VARIABLE INITIAL DATA FOR DCS CRC ERROR(DCSPMC2)
The DCSPMC2 detected that the CRC of the variable number initialization data for DCS is
invalid.
Number
Message
Contents
PW10184
DO SELF TEST ERROR(DCSPMC1)
The DCSPMC1 detected an error in the DO self test function.
Number
Message
Contents
PW10185
DO SELF TEST ERROR(DCSPMC2)
The DCSPMC2 detected an error in the DO self test function.
Number
Message
Contents
PW10186
DCS PMC EXEC TIME ERROR(DCSPMC1)
Processing time for safe ladder execution could not be secured at the DCSPMC1.
Number
Message
Contents
PW10187
DCS PMC EXEC TIME ERROR(DCSPMC2)
Processing time for safe ladder execution could not be secured at the DCSPMC2.
421
Alarm list
B-64805EN/03
Number
Message
Contents
PW10188
SYSTEM ERROR(DCSPMC1)
The DCSPMC1 detected a critical error.
Number
Message
Contents
PW10189
SYSTEM ERROR(DCSPMC2)
The DCSPMC2 detected a critical error.
Number
Message
Contents
PW10190
SAFETY I/O LINK I ASSIGNMENT DATA CRC ERROR(DCSPMC1)
The DCSPMC1 detected that the CRC of the safety I/O Link i assignment data is invalid.
Number
Message
Contents
PW10191
SAFETY I/O LINK I ASSIGNMENT DATA CRC ERROR(DCSPMC2)
The DCSPMC2 detected that the CRC of the safety I/O Link i assignment data is invalid.
Number
Message
PW10192
SAFETY I/O LINK I ASSIGNMENT DATA DIFFERS FROM THE REGISTERED
DATA(DCSPMC1)
The DCSPMC1 detected that the loaded safety I/O Link i assignment data is different from the
registered data.
Contents
Number
Message
Contents
PW10193
SAFETY I/O LINK I ASSIGNMENT DATA DIFFERS FROM THE REGISTERED
DATA(DCSPMC2)
The DCSPMC2 detected that the loaded safety I/O Link i assignment data is different from the
registered data.
Number
Message
Contents
PW10194
REGISTERED DATA IS BROKEN(DCSPMC1)
The DCSPMC1 detected that the registered data is broken.
Number
Message
Contents
PW10195
REGISTERED DATA IS BROKEN(DCSPMC2)
The DCSPMC2 detected that the registered data is broken.
Number
Message
Contents
PW10196
I/O UNIT FOR DCS DIFFERS FROM THE REGISTERED DATA (DCSPMC1)
The DCSPMC1 detected that the connection of safety I/O unit is changed.
Number
Message
Contents
PW10197
I/O UNIT FOR DCS DIFFERS FROM THE REGISTERED DATA (DCSPMC2)
The DCSPMC2 detected that the connection of safety I/O unit is changed.
Number
Message
Contents
PW10198
VARIABLE INITIAL DATA FOR DCS SIZE OVER(DCSPMC1)
The DCSPMC1 detected that the size of the variable initial data exceeds the maximum size.
Number
Message
Contents
PW10199
VARIABLE INITIAL DATA FOR DCS SIZE OVER(DCSPMC2)
The DCSPMC2 detected that the size of the variable initial data exceeds the maximum size.
422
B-64805EN/03
Alarm list
Number
Message
Contents
PW10200
POSITION ERROR BETWEEN CNC TO SURVO
Reference point establishment by G28 was improperly interrupted
Alarm
Message
Description
PW10201
MEXE PROGRAM TOTAL SIZE OVER
MEXE PROGRAM TOTAL SIZE OVER
Alarm
Message
Contents
PW10202
MEXE PROGRAM PARITY ERROR
MEXE PROGRAM PARITY ERROR
Alarm
Message
Contents
PW10203
ILLEGAL PARAMETER (INCREMENT SYSTEM)
Multiple bits are set to 1 in bits 0 to 3 (ISA to ISE) of parameter No. 1013.
Alarm
Message
Contents
PW10204
USER FILE AREA INVALID
The relationship between the user file area size and the number of files is invalid.
Alarm
Message
Contents
PW10205
USER FILE AREA TOO LARGE
The user file area size has exceeded the maximum settable value.
2.1.9.
Spindle Alarms (SP Alarm)
Number
Message
Contents
SP0740
RIGID TAP ALARM : EXCESS ERROR
The amount of positional deviation for the stopped spindle during rigid tapping has exceeded
the setting value of parameter No. 5313.
Number
Message
Contents
SP0741
RIGID TAP ALARM : EXCESS ERROR
1. The amount of positional deviation for the stopped spindle during rigid tapping has
exceeded the setting value of parameter No. 5311.
2. In rigid tapping, the amount of synchronization error exceeded the setting value of
parameter No. 5214.
Number
Message
Contents
SP0742
RIGID TAP ALARM : LSI OVERFLOW
An LSI overflow has occurred for the spindle during rigid tapping.
Number
Message
Contents
SP0752
SPINDLE MODE CHANGE ERROR
Switching to Cs contour mode, spindle positioning, rigid tap mode, or spindle control mode
did not terminate properly in spindle control. The alarm is activated if the spindle control
unit does not respond correctly to the mode change command issued by the CNC.
When rigid tapping with a spindle in another path is specified, the spindle is in a mode
other than spindle control (e.g., Cs contour control or spindle synchronous control).
Switch the mode of the spindle for which to perform rigid tapping to the spindle control
mode before start of the rigid tapping.
423
Alarm list
B-64805EN/03
Number
Message
Contents
SP0754
ABNORMAL TORQUE
An abnormal load was detected in a spindle motor.
The alarm can be canceled by RESET.
Number
Message
Contents
SP0755
SAFETY FUNCTION ERROR(SP)
An error occurred in safety functions of the n-th spindle: The CNC CPU detected that the safely
function of the n-th spindle was not executed. Alternatively, the result of a CNC safety function
check did not match the result of a spindle safety function check.
Number
Message
Contents
SP0756
ILLEGAL AXIS DATA
The CNC detected an error during transfer of spindle data in the n-th spindle. When this alarm
is issued because the configuration of the spindle amplifiers was changed, set the spindle
number for the spindle amplifier (set bit 7 of parameter No. 4541 to 1 and then 0, and turn the
power to the entire system off).
Number
Message
Contents
SP0757
SAFETY SPEED OVER(DCS_S1)
The DCS_S1 detected that during safety monitoring (the safety check request signal
(*VLDPs) is 0), the spindle motor speed was greater than the safety limit speed on the n-th
spindle. Operate within the safety speed.
Number
Message
Contents
SP1202
SPINDLE SELECT ERROR
In a multi-spindle control, the spindle number other than the valid spindle number was selected
by a position coder select signal. An attempt was made to select the spindle number of the
system having no valid spindle.
Number
Message
Contents
SP1210
TOOL CHANGE SP MOTION OVERFLOW
The distribution amount for the spindle is excessive (FANUC ROBODRILL-specific).
Number
Message
Contents
SP1211
TOOL CHANGE SP ORTN EXCESS ERROR
Excess orientation error was detected for the spindle during tool change (FANUC
ROBODRILL-specific).
Number
Message
Contents
SP1212
TOOL CHANGE SP MOVE EXCESS ERROR
Excess travel error was detected for the spindle during tool change (FANUC ROBODRILLspecific).
Number
Message
Contents
SP1213
TOOL CHANGE SP STOP EXCESS ERROR
Excess stop error was detected for the spindle during tool change (FANUC ROBODRILLspecific).
Number
Message
Contents
SP1214
TOOL CHANGE SP ILLEGAL SEQUENCE
Spindle sequence abnormality was detected for the spindle during tool change (FANUC
ROBODRILL-specific).
424
B-64805EN/03
Alarm list
Number
Message
Contents
SP1220
SPINDLE AMPLIFIER NOT DETECTED
Either the cable connected to a spindle amplifier is broken, or the spindle amplifier is not
connected.
Number
Message
Contents
SP1221
ILLEGAL MOTOR NUMBER
The spindle No. and the motor No. are incorrectly matched.
Number
Message
Contents
SP1224
ILLEGAL SPINDLE-POSITION CODER GEAR RATIO
The spindle-position coder gear ratio was incorrect.
Number
Message
Contents
SP1227
RECEIVING ERROR(SERIAL SPINDLE)
A receive error occurred in communications between the CNC and the spindle amplifier.
Number
Message
Contents
SP1228
COMMUNICATION ERROR(SERIAL SPINDLE)
A communications error occurred between the CNC and the spindle amplifier.
Number
Message
Contents
SP1229
COMMUNICATION ERROR SERIAL SPINDLE AMP.
A communications error occurred between spindle amplifiers (motor Nos. 1 and 2, or motor
Nos. 3-4).
Number
Message
Contents
SP1231
SPINDLE EXCESS ERROR (MOVING)
The position deviation during spindle rotation was greater than the value set in parameters.
Number
Message
Contents
SP1232
SPINDLE EXCESS ERROR (STOP)
The position deviation during spindle stop was greater than the value set in parameters.
Number
Message
Contents
SP1233
POSITION CODER OVERFLOW
The error counter/speed instruction value of the position coder overflowed.
Number
Message
Contents
SP1234
GRID SHIFT OVERFLOW
Grid shift overflowed.
Number
Message
Contents
SP1240
DISCONNECT POSITION CODER
The analog spindle position coder is broken.
Number
Message
Contents
SP1241
D/A CONVERTER ERROR
The D/A converter for controlling analog spindles is erroneous. There is a possibility of cable
earth or noise fault.
425
Alarm list
B-64805EN/03
Number
Message
Contents
SP1243
ILLEGAL SPINDLE PARAMETER SETTING(GAIN)
The setting for the spindle position gain is incorrect.
Number
Message
Contents
SP1244
MOTION VALUE OVERFLOW
The amount of distribution to a spindle is too much.
Number
Message
Contents
SP1245
COMMUNICATION DATA ERROR
A communication data error was detected on the CNC.
Number
Message
Contents
SP1246
COMMUNICATION DATA ERROR
A communication data error was detected on the CNC.
Number
Message
Contents
SP1247
COMMUNICATION DATA ERROR
A communication data error was detected on the CNC.
Number
Message
Contents
SP1252
ILLEGAL SPINDLE PARAMETER SETTING(TANDEM)
Setting of parameter No.4597 is invalid. Causes of the alarm are as follows.
A value that is larger than the maximum designation of spindle axes is set in parameter
No. 4597.
A negative value except for -1 is set in parameter No.4597.
Relationship of master axis and slave axis that is set in parameter No.4597 is illegal.
When the spindle amplifier that is not applicable the function is used, a value except for 0
is set in parameter No.4597.
Number
Message
Contents
SP1255
CAN NOT CHANGE SPINDLE MODE
In the analog spindle control, rigid tapping and spindle positioning can not be used except
when the number of pulses output from the position coder of the spindle is 4096pulse/rev.
Number
Message
Contents
SP1256
SPINDLE PHASE-SYNC IMPOSSIBLE
Arbitrary spindle position phase synchronous control cannot be executed. Save the spindle
position.
Number
Message
Contents
SP1257
ILLEGAL PARAMETER (No.3791#0)
The parameter SSE(No.3791#0) is illegal setting.
Causes of the alarm are as follows.
The bit 0 (SSE) of parameter No. 3791 setting differs between the master and slave.
Please use the same setting for the following functions.
Spindle synchronous control
Spindle command synchronous control
Polygon turning with two spindles
Parameter SSE is set to 1 in spindle control software that does not support this function.
Set parameter SSE to 0.
Number
Message
SP1258
ILLEGAL SPINDLE PARAMETER SETTING(SOFT)
426
B-64805EN/03
Alarm list
Contents
The parameter setting is illegal. Check the following.
The bit 0 (ORPUNT) of parameter No. 4542 is set to 1 in spindle control software that
does not support this function. Change bit 0 (ORPUNT) of parameter No. 4542 to 0.
Number
Message
Contents
SP1701
SAFETY SPEED ZERO ERROR(DCS_S1)
The DCS_S1 detected that the spindle motor position exceeded the safety speed zero
monitoring width (parameter No.4460) in the n-th axis.
Number
Message
Contents
SP1740
P-TAPPING EXCESS ERROR (STOP)
The positional deviation of the stopped spindle has exceeded the set value of parameter
No.5313 or No.12659 during punch tapping.
Number
Message
Contents
SP1741
P-TAPPING EXCESS ERROR (MOVE)
1. The positional deviation of the moving spindle has exceeded the set value of parameter
No.5311 or No.12654 during punch tapping.
2. Punch tapping synchronization error has exceeded the set value of parameter No. 12644.
Number
Message
Contents
SP1969
SPINDLE CONTROL ERROR
An error occurred in the spindle control on the CNC. Report the conditions (the system
configuration, the operation, the frequency of error occurrence and so on) to FANUC.
Number
Message
Contents
SP1970
SPINDLE CONTROL ERROR
An initialization of a spindle didn't complete in the spindle control on the CNC. Check a state of
the connection between CNC and the spindle amplifier. If this alarm still occurs even after the
check of the connection, report the conditions (the system configuration, the operation, the
frequency of error occurrence and so on) to FANUC.
Number
Message
Contents
SP1971
SPINDLE CONTROL ERROR
An error occurred in the spindle control on the CNC. Report the conditions (the system
configuration, the operation, the frequency of error occurrence and so on) to FANUC.
Number
Message
Contents
SP1972
SPINDLE CONTROL ERROR
An error occurred in the spindle control on the CNC.
Confirm whether or not it isn't selecting the 4th gear in the rigid tapping.
If this alarm occurred in other case, report the conditions (the system configuration, the
operation, the frequency of error occurrence and so on) to FANUC.
Report the conditions (the system configuration, the operation, the frequency of error
occurrence and so on) to FANUC.
Number
Message
Contents
SP1975
ANALOG SPINDLE CONTROL ERROR
A position coder error was detected on the analog spindle.
427
Alarm list
B-64805EN/03
Number
Message
Contents
SP1976
SERIAL SPINDLE COMMUNICATION ERROR
The amplifier No. could not be set to the spindle amplifier.
Number
Message
Contents
SP1977
SERIAL SPINDLE COMMUNICATION ERROR
An error occurred with spindle communication (the reason for the error might be a malfunction
of the spindle control hardware or noise).
Number
Message
Contents
SP1978
SERIAL SPINDLE COMMUNICATION ERROR
A time-out was detected during communications with the spindle amplifier.
Number
Message
Contents
SP1979
SERIAL SPINDLE COMMUNICATION ERROR
The communications sequence was no longer correct during communications with the spindle
amplifier.
Number
Message
Contents
SP1980
SERIAL SPINDLE AMP. ERROR
Defective SIC-LSI on spindle amplifier
Number
Message
Contents
SP1981
SERIAL SPINDLE AMP. ERROR
An error occurred during reading of the data from SIC-LSI on the analog spindle amplifier side.
Number
Message
Contents
SP1982
SERIAL SPINDLE AMP. ERROR
An error occurred during reading of the data from SIC-LSI on the spindle amplifier side.
Number
Message
Contents
SP1983
SERIAL SPINDLE AMP. ERROR
Could not clear on the spindle amplifier side.
Number
Message
Contents
SP1984
SERIAL SPINDLE AMP. ERROR
An error occurred during spindle amplifier reformatting (the reason for the error might be a
malfunction of the spindle control hardware or noise).
Number
Message
Contents
SP1985
SERIAL SPINDLE CONTROL ERROR
Failed to automatically set parameters
Number
Message
Contents
SP1986
SERIAL SPINDLE CONTROL ERROR
An error occurred during spindle parameter reading (the reason for the error might be a
malfunction of the spindle control hardware or noise).
Number
Message
Contents
SP1987
SERIAL SPINDLE CONTROL ERROR
Defective SIC-LSI on the CNC
428
B-64805EN/03
Alarm list
Number
Message
Contents
SP1988
SPINDLE CONTROL ERROR
An error occurred in the spindle control on the CNC. Report the conditions (the system
configuration, the operation, the frequency of error occurrence and so on) to FANUC.
Number
Message
Contents
SP1989
SPINDLE CONTROL ERROR
An error occurred with spindle communication (the reason for the error might be a malfunction
of the spindle control hardware or noise).
Number
Message
Contents
SP1996
ILLEGAL SPINDLE PARAMETER SETTING
The spindle was assigned incorrectly. Check to see the following parameter.
Parameters Nos. 3716 and 3717
Number
Message
Contents
SP1999
SPINDLE CONTROL ERROR
An error occurred in the spindle control on the CNC. Report the conditions (the system
configuration, the operation, the frequency of error occurrence and so on) to FANUC.
Number
Message
Contents
SP10100
INEXECUTION OF SAFETY FUNCTIONS(SP)
The DCS_S1 detected abnormal condition in the execution of spindle safety functions.
Number
Message
Contents
SP10108
SP SAFETY COMMUNICATION ERROR(DCS_S1)
DCS_S1 detected a communication error between DCS_S1 and spindle control software.
Number
Message
Contents
SP10109
SP SAFETY COMMUNICATION ERROR(DCS_S2)
DCS_S2 detected a communication error between DCS_S2 and spindle control software.
Number
Message
Contents
SP10112
CROSS CHECK ERROR BETWEEN DCS_S1 AND SP_SOFT(DCS_S1)
DCS_S1 detected that the safety function check results between DCS_S1 and spindle Control
Software did not match.
Number
Message
Contents
SP10114
FSSB COMMUNICATION ERROR BETWEEN DCS_S1 AND SP AMP
DCS_S1 detected abnormal data in FSSB communication between DCS_S1 and spindle
amplifier.
Number
Message
Contents
SP10115
MOTOR SENSOR DATA ERROR (DCS_S1)
DCS_S1 failed to get the data from spindle motor sensor.
Number
Message
Contents
SP10116
SPINDLE SENSOR DATA ERROR (DCS_S1)
DCS_S1 failed to get the data from spindle sensor.
429
Alarm list
2.1.10.
B-64805EN/03
Overheat Alarms (OH Alarm)
Number
Message
Contents
OH0704
OVERHEAT
Spindle overheat due to spindle speed fluctuation detection.
When the cutting load is large, offload the cutting conditions.
Check if the cutting tool became dull.
Check if the spindle amplifier malfunctions.
Number
Message
Contents
OH10000
CNC UNIT OVERHEATED (MAIN BOARD)
The following board in the CNC unit has reached an abnormal temperature.
Main board
Number
Message
Contents
OH10001
CNC UNIT OVERHEATED (MAIN BOARD)
The following board in the CNC unit has reached an abnormal temperature.
Main board
Number
Message
Contents
OH10002
CNC UNIT OVERHEATED (MAIN BOARD)
The following board in the CNC unit has reached an abnormal temperature.
Main board
Number
Message
Contents
OH10003
CNC UNIT OVERHEATED (CPU BOARD)
The following board in the CNC unit has reached an abnormal temperature.
CPU board
2.1.11.
Other Alarms (DS Alarm)
Number
Message
Contents
DS0001
SYNC EXCESS ERR (POS DEV)
In axis synchronous control, the difference in the amount of positional deviation between the
master and slave axes exceeded the parameter No. 8323 setting value.
This alarm occurs for the master or slave axis.
Number
Message
Contents
DS0002
SYNC EXCESS ERROR ALARM 1
In axis synchronous control, the difference in the amount of synchronization between the
master and slave axes exceeded the parameter No. 8331 setting value.
This alarm occurs only for the slave axis.
Number
Message
Contents
DS0003
SYNCHRONIZE ADJUST MODE
The system is in the adjust mode with axis synchronous control.
Number
Message
Contents
DS0004
EXCESS MAXIMUM FEEDRATE
The malfunction prevent function detected the command in which a value exceeding the
maximum speed was specified.
430
B-64805EN/03
Alarm list
Number
Message
Contents
DS0005
EXCESS MAXIMUM ACCELERATION
The malfunction prevent function detected the command in which a value exceeding the
maximum acceleration was specified.
Number
Message
Contents
DS0006
ILLEGAL EXECUTION SEQUENCE
The malfunction prevent function detected an illegal execution sequence.
Number
Message
Contents
DS0007
ILLEGAL EXECUTION SEQUENCE
The malfunction prevent function detected an illegal execution sequence.
Number
Message
Contents
DS0008
ILLEGAL EXECUTION SEQUENCE
The malfunction prevent function detected an illegal execution sequence.
Number
Message
Contents
DS0009
ILLEGAL EXECUTION SEQUENCE
The malfunction prevent function detected an illegal execution sequence.
Number
Message
Contents
DS0010
ILLEGAL REFERENCE AREA
The malfunction prevent function detected an illegal reference area.
Number
Message
Contents
DS0011
ILLEGAL REFERENCE AREA
The malfunction prevent function detected an illegal reference area.
Number
Message
Contents
DS0012
ILLEGAL REFERENCE AREA
The malfunction prevent function detected an illegal reference area.
Number
Message
Contents
DS0013
ILLEGAL REFERENCE AREA
The malfunction prevent function detected an illegal reference area.
Number
Message
Contents
DS0014
TOOL CHANGE DETECT MACHINE LOCK
A machine lock is turned on for the Z axis for which the tool is being changed.
Number
Message
Contents
DS0015
TOOL CHANGE DETECT MIRROR IMAGE
A mirror image is turned on for the Z axis for which the tool is being changed.
Number
Message
Contents
DS0016
SERIAL DCL:FOLLOW-UP ERROR
Setting of parameter Nos. 1883 and 1884 is invalid.
The current position at establishment of the origin subtracted by the distance between the
reference positions (detection unit) exceeded ±2147483647. Change the current position
or reference position to prevent this situation.
431
Alarm list
B-64805EN/03
Number
Message
Contents
DS0017
SERIAL DCL:REF-POS ESTABLISH ERR
The travel amount at the FL speed at establishment of the origin exceeded the setting of
parameter No. 14010.
Number
Message
Contents
DS0018
SERIAL DCL:MISMATCH(SSYNC CTRL)
Of the master and slave axes in axis synchronous control, one axis is a linear scale with the
origin and the other is not a linear scale with the origin. In such a configuration, the feed axis
synchronous control selection signal (SYNC<Gn138> or SYNCJ <Gn140>) needs to be set to
0 to establish the origin.
Number
Message
Contents
DS0019
SERIAL DCL:MISMATCH(ANGL-AXIS)
In angular axis control, one of the angular axis and the Cartesian axis is a linear scale with an
origin, while the other is not a linear scale with an origin. This kind of configuration is not
allowed.
Number
Message
Contents
DS0020
REFERENCE RETURN INCOMPLETE
Upon an automatic reference position return while a reference position return after power-up
has never been performed after a manual reference position return during angular axis control
was performed and power was turned on, an attempt was made to perform an automatic
reference position return on the perpendicular axis before the completion of a reference
position return on the angular axis. First, complete reference position return on the angular
axis, then perform reference position return on the perpendicular axis.
Alarm
Message
Contents
DS0021
START ERROR(ONE-TOUCH MACRO)
The macro program cannot be started.
The feed hold signal *SP is 0.
Alarm is being generated.
The SRN signal is turned on.
Number
Message
Contents
DS0022
DUAL CHECK SAFETY IS NOT WORKED
The Dual Check Safety function is unavailable by setting bit 6 (DCE) of parameter No. 1902 to
0.
Number
Message
Contents
DS0025
G60 CANNOT BE EXECUTED
The state of a mirror image is different between the time when look-ahead of a block for single
direction positioning was performed and the time when execution of the block was started, so
single direction positioning cannot be performed. Modify the program.
Number
Message
Contents
DS0026
MISMATCH OF ANGULAR AXIS(D.C.S)
On angular axis control, one of the angular/perpendicular axes is the scale with ref-pos, and
the other of them is not the scale with ref-pos. This kind of configuration is not allowed.
Number
Message
Contents
DS0027
MISMATCH OF SYNCHRONOUS AXIS(D.C.S)
Of the master and slave axes in axis synchronous control, one of them is the linear scale
with distance-coded reference marks, and the other of them is not the linear scale with
distance-coded reference marks. In such a configuration, the axis synchronous control
432
B-64805EN/03
Alarm list
selection signal (SYNC<Gn138> or SYNCJ <Gn140>) needs to be set to 1 to establish
the origin.
Multiple slave axes are specified for axis synchronous control. Such system is not
admired.
Number
Message
Contents
DS0030
TOOL DIRC CMP IMPOSSIBLE
When workpiece setting error compensation is performed in a 5-axis cutting machine or tool
center point control is performed in the tilted working plane indexing command mode, if settings
are made to make compensation in the tool direction (bit 0 (RCM) of parameter No. 11200 is
1), the position of the rotation axis could not be obtained.
Number
Message
Contents
DS0031
ILLEGAL ADRS CHAR IN INDRCT CMD
Correct the sub-command address character code.
Number
Message
Contents
DS0032
ILLEGAL ADRS TOP IN INDRCT CMD
Specify the correct sub-command top address.
Number
Message
Contents
DS0033
OUT OF DATA RANGE IN SUB CMD
Allocate a sub-command data zone.
Number
Message
Contents
DS0034
ILLEGAL SUB CMD NUMBER
Specify the correct sub-command number.
Number
Message
Contents
DS0035
ILLEGAL DATA LENGTH IN SUB CMD
Specify the correct sub-command data length.
Number
Message
Contents
DS0039
BRAKE TEST ERROR
A brake test did not terminate normally. For the cause of this alarm, check the number
displayed for diagnosis No.3701.
Number
Message
Contents
DS0040
BRAKE TEST ERROR
An error was detected in the n axis during a brake test, and the brake test did not terminate
normally. For the cause of this alarm, check the number displayed for diagnosis No.3701.
Number
Message
Contents
DS0050
TOO MANY SIMULTANEOUS AXES
A movement was performed along more axes than can be controlled by simultaneous axis
control. Check whether a command in the program is specified for more axes than can be
controlled by simultaneous axis control.
Number
Message
Contents
DS0057
CAN NOT COMMAND MOVING AXIS
A travelling axis was specified in smart feed axis acceleration/deceleration.
Specify after stopping the axis.
433
Alarm list
B-64805EN/03
Number
Message
Contents
DS0059
SPECIFIED NUMBER NOT FOUND
[External Data I/O]
In program number and sequence number search, the specified number cannot be found.
There was an I/O request issued for a pot No. or offset (tool data), but either no tool numbers
have been input since power ON.
Or there is no data for the entered tool No.
[External workpiece number search]
The program corresponding to the specified workpiece No. could not be found.
Number
Message
Contents
DS0060
SD CARD ON THE CONTROL UNIT ACCESS ERROR DETECT
The error occurred while accessing the SD card on the control unit side. Check if the SD card
is faulty or if a non-recommended SD card is being used.
Number
Message
Contents
DS0069
MISSING THE MOVE COMMAND
A move command is not specified in the next block to the synchronous start block.
Number
Message
Contents
DS0070
SUPERIMPOSE FOR HIGH-SPEED CYCLE CANNOT BE USED
Superimposed control for high-speed cycle cutting is not enabled. Alternatively, the status is
not the advanced superimposition state.
Number
Message
Contents
DS0071
START OR RELEASE CANNOT BE DONE
To start or cancel the inter-path flexible synchronous mode, the tool must be stopped
along all axes.
To start or cancel advanced superimposition, movement along axes must stop.
Number
Message
Contents
DS0083
THREADING SIGNAL ERROR
Signal setting is invalid.
Causes of the alarm are as follows.
Reference position establishment starting signal CSYC is set to "1" before the Cs
contouring control high speed switching completion signal CSMCx becomes "1".
FIN for start of arbitrary speed threading is returned before the reference position
establishment completion signal becomes "1".
FIN for cancel of arbitrary speed threading is returned before the Cs contouring control
high speed switching completion signal CSMCx becomes "0".
Spindle which is commanded M code for arbitrary speed threading is not specified to get
the feedback pulse from position coder.
State of signal (the Cs contouring control high speed switching completion signal CSMCx
and the reference position establishment completion signal) is not corresponding to
arbitrary speed threading mode.
Number
Message
Contents
DS0087
ILLEGAL OPERATION IN P2ACC MODE
Related parameters were changed during cross rail axis control mode.
A non-executable axis control mode was entered during cross rail axis control mode.
The reference points for the master or slave axis became unestablished during cross rail
axis control mode.
Number
Message
DS0093
EXTERNAL REF RETURN INCOMPLETE
434
B-64805EN/03
Alarm list
Contents
In the reference position external setting function, the reference position cannot be set because
the signal for reference position external setting (ZPEXTx) is set from "0" to "1" in the following
state.
(1) Manual reference position return mode is not selected.
(2) The machine is in emergency stop state.
(3) Reset state.
(4) The axis has not stopped.
(5) Automatic operation.
(6) When the reference position is established and resetting is disabled (bit 1 (ZEAx) of
parameter No.1009 is set to 0).
In addition, a reset or a mode change while executing the reference position external setting
will also result in this alarm.
Number
Message
Contents
DS0094
OVERTRAVEL ( SOFT 3 )
The tool is in the forbidden area of stored stroke check 3.
Number
Message
Contents
DS0095
ABNORMAL SPINDLE LOAD
Spindle load exceeds Abnormal spindle load (parameter No.24755).
Number
Message
Contents
DS0096
SSLC PARAMETER ERROR
There is a wrong setting in the parameters concerning the smart spindle-load control.
The magnitude relation of minimum effective spindle load (parameter No.24752), aiming
spindle load of Constant spindle load control (parameter No.24753, No.24770) and abnormal
spindle load (parameter No.24755) is wrong.
Number
Message
Contents
DS0099
STOP DISTANCE REDUCTION ENABLE
An axis stop was executed with the power failure quick stop function.
Number
Message
Contents
DS0100
OVERTRAVEL ( SOFT 2 )
The tool is in the forbidden area of stored stroke check 2.
Number
Message
Contents
DS0131
TOO MANY MESSAGE
An attempt was made to display an external operator message or external alarm message, but
17 or more displays were required simultaneously.
Number
Message
Contents
DS0132
MESSAGE NUMBER NOT FOUND
An attempt to cancel an external operator message or external alarm message failed because
the specified message number was not found.
Number
Message
Contents
DS0133
TOO LARGE NUMBER
A value other than 0 to 4095 was specified as the external operator message or the external
alarm message number.
Number
Message
DS0139
CAN NOT CHANGE PMC CONTROL AXIS
435
Alarm list
B-64805EN/03
Contents
Modify the program so that axis selection is not performed during PMC axis control commands.
Number
Message
Contents
DS0141
OVERTRAVEL (ILL-EXEC-CHK)
The malfunction prevention function detected an entry into the inner forbidden area of stored
stroke check 2 or the forbidden area of stored stroke check 3.
Number
Message
Contents
DS0143
CNC LOCK FUNCTION IS NOT VALID
The CNC cannot be used since the system data of the CNC lock function was erased. Restore
the system data in case it was erased.
This alarm cannot be cleared by a reset.
Number
Message
Contents
DS0144
EXPIRED, AUTOMATIC OPERATION IS IMPOSSIBLE (CNC LOCK)
The CNC lock function has expired. The CNC automatic operation cannot be used while
expired. Refer to the CNC lock screen.
This alarm cannot be cleared by FANUC. Contact the machine dealer or leaser to extend the
expiration date.
This alarm cannot be cleared by a reset.
Number
Message
Contents
DS0145
CNC ID NUM NOT MATCH (CNC LOCK)
The CNC ID number did not match in the CNC lock function. The CNC hardware might have
been replaced. Restore it to its original system configuration.
This alarm cannot be cleared by a reset.
Number
Message
Contents
DS0146
EXPIRING, AUTOMATIC OPERATION WILL BE IMPOSSIBLE (CNC LOCK)
In the CNC lock function, the remaining days until expiration date is within seven days (or the
setting value of parameter No. 24749). Refer to the CNC lock screen.
If it expires, automatic operation of the CNC will not be possible. Make sure to attend to it
before the expiration date.
The expiration date cannot be changed by Fanuc. Contact the machine dealer or leaser to
extend the expiration date.
This alarm can be cleared by a reset. Even if this alarm is cleared, it will be generated again
when the CNC date changes or when CNC power is turned on again.
Number
Message
Contents
DS0147
REFER TO CNC LOCK SCREEN, CONTACT DEALER OF MACHINE (CNC LOCK)
The CNC lock function is about to expire or has expired. Check the CNC lock screen and
contact the machine dealer or leaser.
Number
Message
Contents
DS0148
ILLEGAL SET WHILE OT PREVENTION
The following was executed while the machine lock was enabled by the OT prevention
function.
Disable the OT prevention function (bit 0 (OPE) of parameter No. 10338 = 0).
Change the range of stored stroke limit 1.
Number
Message
Contents
DS0300
APC ALARM: NEED REF RETURN
A setting to zero position for the absolute position detection (association with reference position
and the position data of the absolute position detector) is required. Perform reference position
return.
436
B-64805EN/03
Alarm list
This alarm may occur with other alarms simultaneously. In this case, other alarms must be
handled first.
Number
Message
Contents
DS0306
APC ALARM: BATTERY VOLTAGE 0
The battery voltage of the absolute position detector has dropped to a level at which data can
no longer be held. Or, the power was supplied to the Pulsecoder for the first time.
The battery or cable is thought to be defective. Replace the battery with the machine turned on.
Number
Message
Contents
DS0307
APC ALARM: BATTERY LOW 1
The battery voltage of the absolute position detector has dropped to a level at which a
replacement is required.
Replace the battery with the machine turned on.
Number
Message
Contents
DS0308
APC ALARM: BATTERY LOW 2
The battery voltage of the absolute position detector dropped to a level at which a replacement
was required in the past (including during power off).
Replace the battery with the machine turned on.
Number
Message
Contents
DS0309
APC ALARM: REF RETURN IMPOSSIBLE
An attempt was made to set the zero point for the absolute position detection by MDI operation
when it was impossible to set the zero point.
Rotate the motor manually at least one turn, and set the zero position of the absolute position
detection after turning the CNC and servo amplifier off and then on again.
Number
Message
Contents
DS0311
APZ OF UNSELECTED FEEDBACK SIDE CAN NOT SET
The alarm will be generated when changing the APZ of the A axis (semi-closed side) in fullclosed mode or changing the APZ of the C axis (full-closed side) in semi-closed mode.
Cannot be changed.
This alarm can be cleared by a reset.
Number
Message
Contents
DS0340
BRAKE TORQUE SHORTAGE
The gravity load torque ratio measured by the brake check has exceeded the threshold value
(parameter No. 11592). The servomotor brake may be broken. Please replace the servo motor
promptly.
Number
Message
Contents
DS0341
BRAKE RELEASE FAILURE
The machine friction torque ratio measured by the brake check has exceeded the threshold
value (parameter No. 11594). Please check if the brake is energized. If it is normally energized,
replace the servo motor promptly.
Number
Message
Contents
DS0342
BRAKE ACTUATION DELAY
The brake actuation time measured by the brake check has exceeded the threshold value
(parameter No. 11596). The servomotor brake may be broken. Please replace the servo motor
promptly.
Number
Message
DS0343
BRAKE CHECK INTERRUPTION
437
Alarm list
B-64805EN/03
Contents
The brake check is not started, or the brake check has been canceled. Please check the
reason with diagnosis data No. 1859.
Number
Message
Contents
DS0405
ZERO RETURN END NOT ON REF
The axis specified in automatic reference position return was not at the correct reference
position when positioning was completed.
Perform return from the position where the distance between the reference position return start
position and the reference position is two or more revolutions of the motor.
Other probable causes are: the positional deviation after triggering the deceleration dog is less
than 128, insufficient voltage or malfunctioning of Pulsecoder, and a failure in the main card.
Number
Message
Contents
DS0582
ILLEGAL TORQUE LIMIT OVERRIDE
Torque limit value is smaller than the torque required to support the axis. Review the override
value for torque limit skip.
Number
Message
Contents
DS0608
SV INTERNAL FAN FAILURE
Internal agitating fan failure.
Number
Message
Contents
DS0609
SV EXTERNAL FAN FAILURE
Radiator cooling fan failure.
Number
Message
Contents
DS0610
SV INTERNAL FAN FAILURE
Internal agitating fan failure.
Number
Message
Contents
DS0611
PS EXTERNAL FAN FAILURE
External radiator cooling fan failure.
Number
Message
Contents
DS0612
PS OVERLOAD
Overheat
Number
Message
Contents
DS0613
PS IMPROPER INPUT POWER
Input power supply fault
Number
Message
Contents
DS0614
PS EXTERNAL INPUT COMPONENT ERROR
There is an error with PS control parameter, cable, or external input devices including PS,
transformer, and input filter.
Number
Message
Contents
DS0650
POLE DETECTION REQUEST
Pole position detection is incomplete (RPFIN1 to RPFIN8 <Fn159> = 0) for the absolute
detection axis (bit 5 (APCx) of parameter No. 1815 = 1).
After completing pole position detection for the non-absolute detection axis (bit 5 (APCx) of
parameter No. 1815 = 0), pole position detection became incomplete (RPFIN1 to RPFIN8
<Fn159> = 0).
438
B-64805EN/03
Alarm list
Number
Message
Contents
DS0651
ACC. ERROR
Communication between the separate detector interface unit and acceleration sensor was
disconnected.
Number
Message
Contents
DS0653
SSM FAILURE
An abnormality occurred in the SSM drive of the servo amplifier.
This alarm may occur in the following case:
The SSM-related parameter settings are illegal.
The SSM or SSM connection cable is defective.
Number
Message
Contents
DS1105
ILLEGAL PARAMETER (3DR-COMP)
Parameter setting for 3-dimensional rotary error compensation is wrong. Causes of the alarm
are as follows.
The setting for rotation axis is wrong.
The number for the total compensation points is larger than 7812.
The setting for compensation axis is wrong.
The setting for machine type is wrong.
The setting for compensation number of reference point is wrong.
The setting for compensation interval is wrong.
Number
Message
Contents
DS1120
UNASSIGNED ADDRESS (HIGH)
The values of the high-order 3 bits (EA4 to EA6) of the external data input interface address
are illegal. Check the PMC sequence program.
Number
Message
Contents
DS1121
UNASSIGNED ADDRESS (LOW)
The values of the low-order 4 bits (EA0 to EA3) of the external data input interface address are
illegal. Check the PMC sequence program.
Number
Message
Contents
DS1128
DI.EIDLL OUT OF RANGE
The numerical value input by external data input signals ED0 to ED31 has exceeded the
permissible range.
Number
Message
Contents
DS1130
SEARCH REQUEST NOT ACCEPTED
The CNC cannot perform program number or sequence number search.
Change to memory mode or reset state.
Number
Message
Contents
DS1131
EXT-DATA ERROR(OTHER)
[External Data I/O]
An attempt was made to input tool data for tool offset by a tool No. during loading by the G10
code.
Number
Message
Contents
DS1150
A/D CONVERT ALARM
A/D converter malfunction
439
Alarm list
B-64805EN/03
Number
Message
Contents
DS1184
PARAMETER ERROR IN TORQUE
An invalid parameter was set for torque control.
The torque constant parameter is set to "0".
Number
Message
Contents
DS1185
OVER MAXIMUM FEED
The max. feedrate or rapid traverse rate was exceeded in G54.3.
Number
Message
Contents
DS1448
ILLEGAL PARAMETER (D.C.S.)
The setting value of parameter for linear scale with absolute address reference marks is
satisfied the following any conditions.
The absolute position detection function is enabled.
Either parameter 1821 (mark-1 interval) or parameter 1882 (mark-2 interval) is set to 0.
Parameters 1821 and 1882 have identical settings.
The difference between the settings made for parameters 1821 and 1882 is greater than
or equal to twice either setting.
The setting value of parameters 1883 and 1884 are over the valid data range.
The bit 0 (RVSx) of parameter No. 1815 = 1 and parameters No. 1868 and 1869 are set to
a value other than 0 for the B type rotary axis.
Number
Message
Contents
DS1449
REFERENCE MARKS ARE DIFFERENT FROM PARAMETER
In case of distance coded linear scale I/F, the actual interval of linear scale with absolute
address reference marks is different from parameters Nos. 1821 and 1882 setting value.
Number
Message
Contents
DS1450
RETURN TO REFERENCE POINT
1st reference position return (CDxX7 to CDxX0: 17h (Hex)) was specified when the manual
reference position return was not executed with the reference position return function enabled
(bit 0 (ZRN) of parameter No. 1005 set to "0").
Number
Message
Contents
DS1451
IMPROPER PMC AXIS COMMAND
The PMC axes cannot be controlled in this state.
Number
Message
Contents
DS1512
EXCESS VELOCITY
The feedrate of the linear axis during polar coordinate interpolation exceeded the maximum
cutting feedrate.
Number
Message
Contents
DS1514
ILLEGAL MOTION IN G12.1 MODE
In a hypothetical axis direction compensation during the polar coordinate interpolation mode,
an attempt is made to travel to the area in which the travel cannot be made.
Number
Message
Contents
DS1553
EXCESS VELOCITY IN G43.4/G43.5
A travel at an axis rate exceeding the maximum cutting feedrate was attempted by the pivot
tool length compensation.
Number
Message
DS1710
ILLEGAL ACC. PARAMETER(OPTIMUM TORQUE ACC/DEC)
440
B-64805EN/03
Alarm list
Contents
There are errors in the parameters of permissible acceleration for Optimum Torque
Acceleration/Deceleration.
The possible causes are:
The ratio of the acceleration for deceleration to the acceleration for the acceleration is
lower than the limited value.
The time required to slow down to a speed of 0 exceeds the maximum.
Number
Message
Contents
DS1711
ILLEGAL ACC. PARAMETER(RIGID TAPPING OPTIMUM ACC/DEC)
The permissible acceleration parameter for optimum torque acceleration/deceleration for rigid
tapping contains an error.
The possible causes are:
The ratio of the deceleration to the acceleration is less than 1/3.
The time required to slow down to a speed of 0 exceeds the maximum.
The maximum acceleration (parameters Nos. 11421 to 11424) is 0.
Number
Message
Contents
DS1931
MACHINE PARAMETER INCORRECT
One of parameters Nos. 19665 to 19667 and Nos.19680 to 19744 used to configure the
machine contains an error.
A 5-axis machining function not supporting the 2-linear axis machine (bit 6 (HAL) of
parameter No. 11269 = 1) was enabled.
Travelling occurred for a non-existent linear axis in the 2-linear axis machine (bit 6 (HAL)
of parameter No. 11269 = 1).
Number
Message
Contents
DS1932
DI.THML SIGNAL ON
One of the parameters used to configure the machine is rewritten while the thermal growth
compensation along tool vector function is enabled.
Number
Message
Contents
DS2015
MANUAL OPRT IN TORQUE CTRL MODE
Manual operation was performed on the axis under torque control.
Number
Message
Contents
DS2016
ILLEGAL OPERATION IN TORQUE MODE
The machine lock status was switched during torque control mode.
Number
Message
Contents
DS2003
ILLEGAL USE FOR SERVO MOTOR SPINDLE
The servo axes for spindle use of the spindle control with servo motor was used by the
following functions.
PMC axis control
Chopping
Number
Message
Contents
DS2091
CAN NOT RETURN TO BREAKPOINT
It was not possible to return to the machine position of the interruption point because of
machine lock.
Number
Message
Contents
DS2092
REVERSE START ERROR(RMFR)
Reverse motion function for cutting restart could not be begun.
This alarm may occur in the following case:
When reverse motion function for cutting restart begins, CNC is not reset status.
441
Alarm list
B-64805EN/03
Interruption block is in a mode that cannot begin reverse motion function for cutting
restart.
The program has never executed before.
The program has never executed after the reverse motion is done until becoming the
reverse end (RVED) by reverse motion function for cutting restart.
Number
Message
Contents
DS2096
ALARM OCCURRED IN MAIN PATH
The alarm occurred in the path that used the peripheral axis control.
Number
Message
Contents
DS2097
ALARM OCCURRED IN PERIPHERAL
The alarm occurred in the peripheral axis control.
Number
Message
Contents
DS2100
SAFE I/O CROSS CHECK ERROR(DCSPMC1)
The I/O cross-check function of DCSPMC1 detected the discrepancy in a system-defined
safety related I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
DS2101
SAFE I/O CROSS CHECK ERROR(DCSPMC2)
The I/O cross-check function of DCSPMC2 detected the discrepancy in a system-defined
safety related I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
DS2102
USER I/O CROSS CHECK ERROR(DCSPMC1)
The I/O cross-check function of DCSPMC1 detected the discrepancy in a programmable safe
I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
DS2103
USER I/O CROSS CHECK ERROR(DCSPMC2)
The I/O cross-check function of DCSPMC2 detected the discrepancy in a programmable safe
I/O signal.
See details on the diagnosis screen of I/O cross-check function.
Number
Message
Contents
DS4603
C AXIS SYNCHRONOUS ERROR
The difference between the position deviation value of C1 axis and C2 axis exceeds the
parameter value (No. 16364, 16365) with the C axis synchronous control function.
Number
Message
Contents
DS4605
NEED ZRN
The C axis synchronization is not done normally.
Number
Message
Contents
DS4610
RAM AXIS POSITION IS WRONG
Ram-axis is not located on the press start position.
Number
Message
DS4800
ZONE : PUNCHING INHIBITED 1
442
B-64805EN/03
Alarm list
Contents
When a safety zone check was executed, a punch command was specified in area 1 where
punching is inhibited.
Number
Message
Contents
DS4801
ZONE : PUNCHING INHIBITED 2
When a safety zone check was executed, a punch command was specified in area 2 where
punching is inhibited.
Number
Message
Contents
DS4802
ZONE : PUNCHING INHIBITED 3
When a safety zone check was executed, a punch command was specified in area 3 where
punching is inhibited.
Number
Message
Contents
DS4803
ZONE : PUNCHING INHIBITED 4
When a safety zone check was executed, a punch command was specified in area 4 where
punching is inhibited.
Number
Message
Contents
DS4804
ZONE : PUNCHING INHIBITED 5
When a safety zone check was executed, a punch command was specified in area 5 where
punching is inhibited.
Number
Message
Contents
DS4805
ZONE : PUNCHING INHIBITED 6
When a safety zone check was executed, a punch command was specified in area 6 where
punching is inhibited.
Number
Message
Contents
DS4806
ZONE : PUNCHING INHIBITED 7
When a safety zone check was executed, a punch command was specified in area 7 where
punching is inhibited.
Number
Message
Contents
DS4807
ZONE : PUNCHING INHIBITED 8
When a safety zone check was executed, a punch command was specified in area 8 where
punching is inhibited.
Number
Message
Contents
DS4810
ZONE : ENTERING INHIBITED 1 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 1 into which entry is inhibited.
Number
Message
Contents
DS4811
ZONE : ENTERING INHIBITED 1 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 1 into which entry is inhibited.
Number
Message
Contents
DS4812
ZONE : ENTERING INHIBITED 2 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 2 into which entry is inhibited.
443
Alarm list
B-64805EN/03
Number
Message
Contents
DS4813
ZONE : ENTERING INHIBITED 2 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 2 into which entry is inhibited.
Number
Message
Contents
DS4814
ZONE : ENTERING INHIBITED 3 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 3 into which entry is inhibited.
Number
Message
Contents
DS4815
ZONE : ENTERING INHIBITED 3 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 3 into which entry is inhibited.
Number
Message
Contents
DS4816
ZONE : ENTERING INHIBITED 4 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 4 into which entry is inhibited.
Number
Message
Contents
DS4817
ZONE : ENTERING INHIBITED 4 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 4 into which entry is inhibited.
Number
Message
Contents
DS4818
ZONE : ENTERING INHIBITED 5 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 5 into which entry is inhibited.
Number
Message
Contents
DS4819
ZONE : ENTERING INHIBITED 5 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 5 into which entry is inhibited.
Number
Message
Contents
DS4820
ZONE : ENTERING INHIBITED 6 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 6 into which entry is inhibited.
Number
Message
Contents
DS4821
ZONE : ENTERING INHIBITED 6 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 6 into which entry is inhibited.
Number
Message
Contents
DS4822
ZONE : ENTERING INHIBITED 7 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 7 into which entry is inhibited.
Number
Message
DS4823
ZONE : ENTERING INHIBITED 7 -X
444
B-64805EN/03
Alarm list
Contents
When a safety zone check was executed, the machine moving in the negative X direction
entered area 7 into which entry is inhibited.
Number
Message
Contents
DS4824
ZONE : ENTERING INHIBITED 8 +X
When a safety zone check was executed, the machine moving in the positive X direction
entered area 8 into which entry is inhibited.
Number
Message
Contents
DS4825
ZONE : ENTERING INHIBITED 8 -X
When a safety zone check was executed, the machine moving in the negative X direction
entered area 8 into which entry is inhibited.
Number
Message
Contents
DS4830
ZONE : ENTERING INHIBITED 1 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 1 into which entry is inhibited.
Number
Message
Contents
DS4831
ZONE : ENTERING INHIBITED 1 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 1 into which entry is inhibited.
Number
Message
Contents
DS4832
ZONE : ENTERING INHIBITED 2 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 2 into which entry is inhibited.
Number
Message
Contents
DS4833
ZONE : ENTERING INHIBITED 2 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 2 into which entry is inhibited.
Number
Message
Contents
DS4834
ZONE : ENTERING INHIBITED 3 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 3 into which entry is inhibited.
Number
Message
Contents
DS4835
ZONE : ENTERING INHIBITED 3 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 3 into which entry is inhibited.
Number
Message
Contents
DS4836
ZONE : ENTERING INHIBITED 4 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 4 into which entry is inhibited.
Number
Message
Contents
DS4837
ZONE : ENTERING INHIBITED 4 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 4 into which entry is inhibited.
445
Alarm list
B-64805EN/03
Number
Message
Contents
DS4838
ZONE : ENTERING INHIBITED 5 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 5 into which entry is inhibited.
Number
Message
Contents
DS4839
ZONE : ENTERING INHIBITED 5 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 5 into which entry is inhibited.
Number
Message
Contents
DS4840
ZONE : ENTERING INHIBITED 6 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 6 into which entry is inhibited.
Number
Message
Contents
DS4841
ZONE : ENTERING INHIBITED 6 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 6 into which entry is inhibited.
Number
Message
Contents
DS4842
ZONE : ENTERING INHIBITED 7 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 7 into which entry is inhibited.
Number
Message
Contents
DS4843
ZONE : ENTERING INHIBITED 7 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 7 into which entry is inhibited.
Number
Message
Contents
DS4844
ZONE : ENTERING INHIBITED 8 +Y
When a safety zone check was executed, the machine moving in the positive Y direction
entered area 8 into which entry is inhibited.
Number
Message
Contents
DS4845
ZONE : ENTERING INHIBITED 8 -Y
When a safety zone check was executed, the machine moving in the negative Y direction
entered area 8 into which entry is inhibited.
Number
Message
Contents
DS4870
AUTO SETTING FEED ERROR
The feed rate of safety zone auto setting is other than the parameter value (No. 16538, No.
16539).
Number
Message
Contents
DS4871
AUTO SETTING PIECES ERROR
In safety zone auto setting, the safety zone pieces are not correct. Or the position detector has
gone wrong, please tell your machine tool builder.
Number
Message
Contents
DS5258
FEED HOLD IN RESTART
When reverse motion function for cutting restart is interrupted by feed hold, this alarm occurs.
446
B-64805EN/03
Alarm list
Number
Message
Contents
DS5259
INTERRUPTED POSITION NOT FOUND
The interrupted machining position (restart point) was not found (the temporarily executed
coordinate value and the coordinate value of the stored interrupted machining point are
different).
This alarm may occur in the following case:
During feed hold state or single block stop, manual intervention was executed.
Number
Message
Contents
DS5340
PARAMETER CHECK SUM ERROR
Because parameters have been modified, the parameter check sum and the standard check
sum do not match.
Restore the original parameter state, or set a standard check sum again.
Number
Message
Contents
DS5346
Sequence program collation error (PMC1)
The PMC1 sequence program has been changed. Return to the registered sequence program
or register the changed sequence program.
Number
Message
Contents
DS5347
Sequence program collation error (PMC2)
The PMC2 sequence program has been changed. Return to the registered sequence program
or register the changed sequence program.
Number
Message
Contents
DS5348
Sequence program collation error (PMC3)
The PMC3 sequence program has been changed. Return to the registered sequence program
or register the changed sequence program.
Number
Message
Contents
DS5349
Sequence program collation error (DCSPMC)
The sequence program of DCSPMC has been changed. Return to the registered sequence
program or register the changed sequence program.
Number
Message
Contents
DS5350
PARAMETER VERIFY ERROR
The parameter is not applied. Apply the changes by resetting.
Number
Message
Contents
DS5352
Sequence program collation error (PMC4)
The PMC4 sequence program has been changed. Return to the registered sequence program
or register the changed sequence program.
Number
Message
Contents
DS5353
Sequence program collation error (PMC5)
The PMC5 sequence program has been changed. Return to the registered sequence program
or register the changed sequence program.
Number
Message
Contents
DS5387
ILLEGAL SET FOR REF. RETURN WITH MECHANICAL STOPPER SETTING
The slave axis is not within the in-position width, for example, when the distance between the
mechanical stoppers for the master and slave axes is larger than the withdrawal distance
specified in parameter No. 7181 or 7182 for the master axis.
447
Alarm list
B-64805EN/03
Adjust the position of the mechanical stoppers or the setting of parameter No. 7181 or 7182.
Number
Message
Contents
DS5550
AXIS IMMEDIATE STOP
The movement along an axis was stopped immediately by the axis immediate stop function.
Number
Message
Contents
DS5579
ILLEGAL COMMAND OF OSCILLATION
The multi-path system contains oscillation axes that cannot be specified at the same time.
This alarm is generated when all of the following conditions are met.
The same spindle is referred to in multiple paths.
The one-axis oscillation-specified axis of each path is non-parallel.
The one-axis oscillation-specified axis of each path is oscillated at the same time.
The mode is turned on by the servo learning oscillation switching signal OSISS<Gn592.7>
in one of the following conditions.
Parameter No. 2439#1 is 0 for the axis specified by parameter No. 25792
The axis specified by parameter No. 25792 exceeds the maximum number of
control axes.
Number
Message
Contents
DS5591
EXCESS VELOCITY IN ORBIT CUT
The arc motion feedrate of each axis by orbit cutting has exceeded the value set in parameter
No. 12725.
Number
Message
Contents
DS5592
EXCESS ACCELERATION IN ORBIT CUT
The arc motion acceleration of each axis by orbit cutting has exceeded the value set in
parameter No. 12723.
Number
Message
Contents
DS10000
PITCH ERROR DATA IS CLEARED IN RESTART OF CNC SYSTEM
Bit 0 (APE) of parameter No. 3602 has been changed.
In the restart of the CNC, the data of the interpolation type pitch error compensation and the
interpolation type straightness compensation are initialized.
If necessary, take the following actions.
- In the case of operation mistake, restore bit 0 (APE) of parameter No. 3602. The initialization
is canceled by this action.
- To save data, back up the pitch error compensation data or SRAM.
Number
Message
Contents
DS10001
MOTION SCRIPT PROCESSING TIME EXCEEDED
The volume of the Motion Script commands that can be processed has exceeded the limit.
Review the program to reduce the amount of the Motion Script commands that are performed
at the same time.
Number
Message
Contents
DS10002
P-CODE VARIABLE CAPACITY EXCEEDED
The P-CODE variable/extended P-CODE variable capacity has exceeded the upper limit.
Number
Message
Contents
DS10003
USER FILE AREA CAPACITY EXCEEDED
The user file area capacity has exceeded the upper limit.
Number
Message
DS10004
HPM OVERHEAT
448
B-64805EN/03
Alarm list
Contents
HPM is overheating.
Number
Message
Contents
DS10100
DCS SETUP MODE IS SELECTED
The Setup Mode is selected.
Number
Message
Contents
DS10101
CURRENTLY SAFETY PARAMETERS CANNOT BE CHANGED
Safety parameters cannot be changed except in the Setup Mode.
Number
Message
Contents
DS10102
ACCEPTANCE TEST MODE TIME OVER
Since 24 hours have passed after the ACT Mode is selected, the setting of No.41580#0 was
set to 0 and switched to the Safety Mode.
Number
Message
Contents
DS10103
SETTING OF THE DETECTOR IS UNCONFIRMED
Setting of the detector is unconfirmed.
Set DCS to the Setup Mode and check the detector settings in the safe position establishment
screen.
Number
Message
Contents
DS10104
SAFETY POSITION ESTABLISHMENT IS UNCONFIRMED
Safety position establishment is unconfirmed. Confirm the safety position on the safe position
establishment screen.
Number
Message
Contents
DS10105
DCS MODE IS CHANGED
The DCS mode is changed.
Number
Message
Contents
DS10106
ACCEPTANCE TEST HAS NOT BEEN DONE
The acceptance test has not been done.
It is necessary to execute the acceptance test and verify the result. If the result is fine, set
No.41027#0 to 1.
Number
Message
Contents
DS10107
CANNOT CHANGE SAFETY PARAMETER BY EXECUTED METHOD
Parameters (No.1946, No.13918, No.41087, No.41088, No.41089, No.41090, No.41091,
No.41092) cannot be changed by the following methods during the acceptance test mode.
Parameter file input
Programmable parameter input (G10L52)
Custom macros, macro executors
Number
Message
Contents
DS10182
DI SELF TEST ERROR(DCSPMC1)
The DCSPMC1 detected an error in the safe DI self-test function.
Number
Message
Contents
DS10183
DI SELF TEST ERROR(DCSPMC2)
The DCSPMC2 detected an error in the safe DI self-test function.
449
Alarm list
B-64805EN/03
Number
Message
Contents
DS10184
DI SELF TEST EVEN BIT DRIVER ERROR(DCSPMC1)
The DCSPMC1 detected an error in the safe DI self-test even bit driver.
Number
Message
Contents
DS10185
DI SELF TEST EVEN BIT DRIVER ERROR(DCSPMC2)
The DCSPMC2 detected an error in the safe DI self-test even bit driver.
Number
Message
Contents
DS10186
DI SELF TEST ODD BIT DRIVER ERROR(DCSPMC1)
The DCSPMC1 detected an error in the safe DI self-test odd bit driver.
Number
Message
Contents
DS10187
DI SELF TEST ODD BIT DRIVER ERROR(DCSPMC2)
The DCSPMC2 detected an error in the safe DI self-test odd bit driver.
Number
Message
Contents
DS10188
SAFETY LADDER SCAN TIME OVER(DCSPMC1)
At the DCSPMC1, the level 2 scan time of the safety ladder program exceeded the upper limit
(parameter No.41032).
Number
Message
Contents
DS10189
SAFETY LADDER SCAN TIME OVER(DCSPMC2)
At the DCSPMC2, the level 2 scan time of the safety ladder program exceeded the upper limit
(parameter No.41032).
Number
Message
Contents
DS10400
IDROM DATA IS BROKEN (CPU BOARD)
The data in the nonvolatile memory on the CPU board is partially corrupted.
Number
Message
Contents
DS10401
IDROM DATA IS BROKEN (MEMORY BOARD)
The data in the nonvolatile memory on the memory board is partially corrupted.
Number
Message
Contents
DS10403
IDROM DATA IS BROKEN (INTERFACE BOARD)
The data in the nonvolatile memory on the interface board has been partially corrupted.
Number
Message
Contents
DS10404
IDROM DATA IS BROKEN (MAIN BOARD)
The data in the nonvolatile memory on the main board is partially corrupted.
Number
Message
Contents
DS10405
IDROM DATA IS BROKEN (POWER SUPPLY BOARD)
The data in the nonvolatile memory on the power supply board has been corrupted.
Number
Message
Contents
DS10407
IDROM DATA IS BROKEN (BACK BOARD)
The data in the nonvolatile memory on the back board is partially corrupted.
Number
DS10408
450
B-64805EN/03
Alarm list
Message
Contents
IDROM DATA IS BROKEN (EXPANSION BOARD)
The data in the nonvolatile memory on the expansion board is partially corrupted.
Number
Message
Contents
DS10409
IDROM DATA IS BROKEN (OPTION BOARD1)
The data in the nonvolatile memory on the optional board is partially corrupted.
Number
Message
Contents
DS10410
IDROM DATA IS BROKEN (OPTION BOARD2)
The data in the nonvolatile memory on the optional board is partially corrupted.
Number
Message
Contents
DS10411
IDROM DATA IS BROKEN (OPTION BOARD3)
The data in the nonvolatile memory on the optional board is partially corrupted.
Number
Message
Contents
DS10412
IDROM DATA IS BROKEN (OPTION BOARD4)
The data in the nonvolatile memory on the optional board is partially corrupted.
Number
Message
DS10414
ILLEGAL SETTING OF STORED STROKE LIMIT RANGE SWITCHING FUNCTION BY
SIGNAL
The setting of the stored stroke limit range switching by the signal is incorrect.
Contents
Number
Message
Contents
DS10420
AUTOMATIC DATA BACKUP FAILED(BACKUP DATA1 CANNOT BE BACKED UP)
Backup to backup data 1 in automatic data backup is prohibited. (Bit 0 of parameter 10343 is
set to 1.)
Number
Message
Contents
DS10421
AUTOMATIC DATA BACKUP FAILED(FAILED TO BACKUP A NEW BACKUP FILE)
There is not enough free space in internal storage and a new backup file cannot be backed up
in automatic data backup.
Number
Message
Contents
DS10422
AUTOMATIC DATA BACKUP FAILED(FAILED TO OVERWRITE)
There is not enough free space in internal storage and overwrite backup cannot be performed
in automatic data backup.
Number
Message
Contents
DS10423
AUTOMATIC DATA BACKUP FAILED(NOT IN EMERGENCY STOP STATE)
CNC is not in emergency stop state at the start of automatic data backup.
Number
Message
Contents
DS10424
AUTOMATIC DATA BACKUP FAILED(FILE ACCESS INTERNAL ERROR)
An internal error occurred in accessing the file during automatic data backup.
Number
Message
Contents
DS10430
CLOCK TIME HAS BEEN RESET
The set time has been reset due to a drop in the voltage used for time keeping.
451
Alarm list
Number
Message
Contents
2.1.12.
B-64805EN/03
DS10440
BOOT SOFT IS BROKEN
Boot software update failure or main board damage.
Malfunction Prevention Function Alarms (IE Alarm)
Number
Message
Contents
IE0001
+ OVERTRAVEL(SOFT 1)
The malfunction prevent function detected that stored stroke check 1 on the positive side was
exceeded.
Number
Message
Contents
IE0002
- OVERTRAVEL(SOFT 1)
The malfunction prevent function detected that stored stroke check 1 on the negative side was
exceeded.
Number
Message
Contents
IE0003
+ OVERTRAVEL(SOFT 2)
The malfunction prevent function detected that stored stroke check 2 on the positive side was
exceeded.
Number
Message
Contents
IE0004
- OVERTRAVEL(SOFT 2)
The malfunction prevent function detected that stored stroke check 2 on the negative side was
exceeded.
Number
Message
Contents
IE0005
+ OVERTRAVEL(SOFT 3)
The malfunction prevent function detected that stored stroke check 3 on the positive side was
exceeded.
Number
Message
Contents
IE0006
- OVERTRAVEL(SOFT 3)
The malfunction prevent function detected that stored stroke check 3 on the negative side was
exceeded.
Number
Message
Contents
IE0007
EXCESS MAXIMUM REV. DATA
The malfunction prevent function detected the command in which a value exceeding the
maximum speed was specified.
Number
Message
Contents
IE0008
ILLEGAL ACC/DEC
The malfunction prevent function detected the acceleration/deceleration error.
2.1.13.
Number
Message
452
PMC Alarms (PMC Alarm)
PMC0001
SEQUENCE PROGRAM IS NOT RUNNING
B-64805EN/03
Alarm list
Contents
Action
The sequence program is stopped.
Start the sequence program.
Number
Message
Contents
Action
PMC1001
NON-VOLATILE DATA ERROR (INVALID DATA)
PMC retention data must be initialized.
Clear the PMC retentive memory on the BOOT screen.
Number
Message
Contents
Action
PMC1002
PT/NT INITIALIZATION ERROR
There are too many rising edge detection contact instructions (PT) and falling edge detection
contact instructions (NT).
Reduce the number of instructions.
Number
Message
Contents
Action
PMC1003
VARIABLE DEFINITION ERROR (TOO LARGE SIZE)
Too many variable definitions.
Reduce the number of variable definitions.
Number
Message
Contents
Action
PMC1004
VARIABLE DEFINITION ERROR(NON-VOLATILE DATA)
The variable definition differs from the definition stored in the CNC.
Check the variable definitions. Or, clear the nonvolatile data.
For information on how to clear it, see "Initializing the stored variables" in "Series 500i-A PMC
Programming Manual" (B-64803EN-3).
Number
Message
Contents
Action
PMC1005
VARIABLE DEFINITION ERROR (SHARED VARIABLES)
The definition of shared variables or common user-defined data types does not match.
Check each definition in the sequence program.
Number
Message
Contents
Action
PMC1006
DATA MANAGEMENT FILE ERROR (VERSION MISMATCH)
The PMC nonvolatile data and PMC data management file must be initialized.
Clear the PMC retentive memory on the BOOT screen.
Number
Message
Contents
Action
PMC2001
SETTING ERROR (EXECUTION CYCLE)
The execution cycle setting of the sequence program is illegal.
Check parameter No. 11930.
Number
Message
Contents
Action
PMC2002
SETTING ERROR (EXECUTION ORDER)
The execution order setting of the multi-PMC function is invalid.
Check to see the parameter Nos. 11900 to 11904.
Number
Message
Contents
Action
PMC2003
SETTING ERROR (EXECUTION TIME RATIO)
The execution time ratio setting of the multi-path PMC function is invalid.
Check to see the parameter Nos. 11905 to 11909.
Number
PMC2004
453
Alarm list
B-64805EN/03
Message
Contents
Action
SETTING ERROR (CNC-PMC I/F)
The interface setting between CNC and PMC is invalid.
Check parameters No. 11920 to 11929 and No. 45000 to 45019.
Number
Message
Contents
Action
PMC2005
SETTING ERROR (MULTI-PMC I/F)
The interface setting between PMC paths is illegal.
Check parameter No. 11932.
Number
Message
Contents
Action
PMC3001
SEQUENCE PROGRAM ERROR (NO PROGRAM)
The sequence program is not found.
Enter the sequence program.
Number
Message
Contents
Action
PMC3002
SEQUENCE PROGRAM ERROR (TOO LARGE SIZE)
The sequence program could not load because the total PMC data size exceeded the program
memory capacity.
Reduce PMC data or request additional PMC program memory options.
Number
Message
Contents
Action
PMC3003
SEQUENCE PROGRAM ERROR (INVALID DATA)
The sequence program is not recognized.
Enter a correct sequence program.
Number
Message
Contents
Action
PMC3004
SEQUENCE PROGRAM ERROR (CORRUPTION)
The sequence program is corrupted.
Enter a correct sequence program.
Number
Message
Contents
Action
PMC3005
SEQUENCE PROGRAM ERROR (UNSUPPORTED)
An unsupported function is used in the sequence program.
Do not use the function that is not supported or request CNC software version upgrade.
Number
Message
Contents
Action
PMC3006
SEQUENCE PROGRAM ERROR (MODEL MISMATCH)
This is a sequence program that cannot be handled by this PMC.
Use FANUC PMC Programmer to convert the PMC model in the sequence program.
Number
Message
Contents
Action
PMC3007
PROGRAM EXECUTION MEMORY OVER
Program code is too large.
Reduce the program.
Number
Message
Contents
Action
PMC3008
SEQUENCE PROGRAM ERROR (UNKNOWN INSTRUCTION)
An unknown functional instruction is used in the sequence program.
Substitute it with a different instruction or request a CNC software update.
Number
Message
PMC3101
PMC MESSAGE DATA EXECUTION MEMORY OVER
454
B-64805EN/03
Alarm list
Contents
Action
The PMC message data is too large.
Reduce the message data.
Number
Message
Contents
Action
PMC9001
UNSUPPORTED INSTRUCTION
An unsupported functional instruction is used in the sequence program.
Substitute it with a different instruction or request a CNC software update.
Number
Message
Contents
Action
PMC9002
WINDR/W INSTRUCTION IS DEACTIVATED
The sequence program was stopped while functional instruction WINDR or WINDW was
running.
Because the function instructions can no longer run, reset the CNC.
Number
Message
Contents
Action
PMC9003
EXIN INSTRUCTION IS DEACTIVATED
The sequence program was stopped while functional instruction EXIN was running.
Because the function instruction can no longer run, reset the CNC.
Number
Message
Contents
Action
PMC9004
AXCTL INSTRUCTION IS DEACTIVATED
The sequence program was stopped while functional instruction AXCTL was running.
Because the function instruction can no longer run, reset the CNC.
Number
Message
Contents
Action
PMC9005
RS-232C INSTRUCTION IS DEACTIVATED
The sequence program was stopped while RS-232C-related functional instruction was running.
Because the function instructions can no longer run, reset the CNC.
Number
Message
Contents
Action
PMC9007
SEQUENCE PROGRAM ERROR (UNKNOWN DATA)
The sequence program contains unknown data.
Do not use the function that is not supported or request CNC software version upgrade.
Number
Message
Contents
Action
PMC9008
MAIN SEQUENCE PROGRAM IS NOT FOUND
There is no main sequence program.
Enter the main sequence program.
Number
Message
Contents
Action
PMC9011
POU STACK OVERFLOW
Stack overflow occurred in the POU.
Reduce the size of the temporary variables used in the sequence program.
For details, see "Temporary variable memory" in "Series 500i-A PMC Programming Manual"
(B-64803EN-3).
Number
Message
Contents
Action
PMC9012
POU CALL DEPTH OVERFLOW
The function or function block call depth has exceeded 16.
Correct the sequence program so that the call depth is 16 or less.
Number
PMC9013
455
Alarm list
B-64805EN/03
Message
Contents
Action
SUB-PROGRAM CALL DEPTH OVERFLOW
The subprogram call depth exceeds 16 depths.
Correct the sequence program so that the call depth is 16 or less.
Number
Message
Contents
Action
PMC9041
PMC MESSAGE DATA ERROR (TOO LARGE SIZE)
The PMC message data could not load because the total PMC data size exceeded the
program memory capacity.
Reduce PMC data or request additional PMC program memory options.
Number
Message
Contents
Action
PMC9042
PMC MESSAGE DATA ERROR (INVALID DATA)
The PMC message data cannot be recognized.
Enter the correct PMC message data.
Number
Message
Contents
Action
PMC9043
PMC MESSAGE DATA ERROR (CORRUPTION)
The PMC message data is corrupted.
Enter the correct PMC message data.
Number
Message
Contents
Action
PMC9044
PMC MESSAGE DATA ERROR (UNSUPPORTED)
The PMC message data is using an unsupported function.
Do not use the function that is not supported or request CNC software version upgrade.
Number
Message
Contents
Action
PMC9045
PMC MESSAGE DATA ERROR (VARIABLE UNDEFINED)
An undefined variable is used in the PMC message data.
Correct the sequence program or PMC message data.
Number
Message
Contents
Action
PMC9046
PMC MESSAGE DATA ERROR (VARIABLE INVALID)
In the PMC message data, a variable is used that was assigned an address other than A
address.
Correct the sequence program or PMC message data.
Number
Message
Contents
Action
PMC9047
PMC MESSAGE DATA ERROR (DUPLICATE DEFINITION)
Multiple messages are defined for one A address.
Correct the PMC message data or sequence program variable definitions.
Number
Message
Contents
Action
PMC9048
PMC MESSAGE DATA ERROR (UNKNOWN DATA)
The PMC message data contains unknown data.
Do not use the function that is not supported or request CNC software version upgrade.
Number
Message
Description
Action
PMC9051
RESTART CNC IS REQUIRED FOR UPDATING THE PMC DATA
Changes requiring rebooting the CNC have been made to PMC data.
Restart the CNC.
This alarm is not cleared by PMC data change cancellation such as cancellation of deletion
reservation.
456
B-64805EN/03
Number
Message
Contents
Action
2.1.14.
Number
Message
Contents
Action
Number
Message
Contents
Action
Alarm list
PMC9053
AUTOMATIC TRACE RESULT SAVING FAILED
The trace result could not be saved at the end of trace function.
Check that destination storage is properly connected.
Additionally, check there is enough space on the storage.
I/O Link i Alarms (IOL Alarm)
IOL0001
WRONGNUMBEROFI/OUNITS (CHn GRxx)
The number of units set by the I/O unit allocation and I/O Link i allocation selection function
parameters differs from the number of I/O units actually connected to the CNC. I/O units
connected to all channels are not linked. The sequence program is executed regardless of this
alarm.
See details on the I/O Link i screen.
When this alarm occurs on a well-worked machine, the cause may be the following.
The failure of the cable or contact from group ("xx" - 1) to "xx".
The power of an I/O device of group "xx" or later is turned off. Or the power on is delayed.
The failure of an I/O device of group "xx" (or "xx" - 1).
There are I/O units whose power is still ON when turning the CNC power from OFF to ON
(make sure to turn all I/O units OFF once when switching CNC power from OFF to ON.)
If this alarm occurs during a debugging of sequence program, the following causes also come
up.
The group number of I/O unit is invalid.
There is an error in the I/O unit allocation setting.
There is an error in the parameter setting of the I/O Link i assignment data selection
function.
There is an error in the machine signal interface setting.
IOL0002
WRONG CONFIGURATION OF I/O UNITS (CHn)
The I/O unit connected to the CNC is different from the I/O unit configuration registered on the
I/O Link i screen. I/O units connected to all channels are not linked. The sequence program is
executed regardless of this alarm.
See details on the I/O Link i screen.
When this alarm occurs on a well-worked machine, the cause may be the following.
Disconnection of communication cable or contact fault.
The power of some I/O units is turned off. Or the power on is delayed.
The failure of some I/O units.
There are I/O units whose power is still ON when turning the CNC power from OFF to ON.
(Make sure to turn all I/O units OFF once when switching CNC power from OFF to ON.)
If this alarm occurs during a debugging of sequence program, the following causes also come
up.
The configuration (type, order or number) of the I/O unit is wrong.
Invalid I/O unit configuration data is registered.
Number
Message
Contents
Action
IOL0003
TOO MANY MEASURING I/O UNITS
Five or more Measurement I/O Units are connected.
Reduce the number of measurement I/O units connected to four or less.
Number
Message
Contents
IOL0004
WRONG CONFIGURATION OF SLICE I/O (CHn GRxx)
There are two patterns.
457
Alarm list
B-64805EN/03
For the groups set by the I/O unit assignment and I/O Link i assignment selection function
Action
Number
Message
Contents
Action
Number
Message
Contents
parameters, I/O units other than Slice I/O are connected to the CNC for the Slice I/O
group.
For the groups set by the I/O unit assignment and I/O Link i assignment selection function
parameters, Slice I/O units are connected to the CNC for the I/O unit groups other than
the Slice I/O group.
I/O units connected to all channels are not linked. The sequence program is executed
regardless of this alarm.
See details on the I/O Link i screen.
If this alarm occurs during a debugging of sequence program, the following causes also come
up.
Slice I/O allocation is set for I/O units other than the connected Slice I/O.
Allocations other than Slice I/O are set for the connected Slice I/O.
There is an error in the parameter setting of the I/O Link i assignment data selection
function.
IOL0005
WRONG NUMBER OF I/O MODULES (SLOTS) (CHn GRxx SLyy)
The number of slots in the Slice I/O group set by the Slice I/O allocation and I/O Link i
allocation selection function parameters is different from the number of connected modules in
the Slice I/O group that are actually connected to the CNC. I/O units connected to all channels
are not linked. The sequence program is executed regardless of this alarm.
See details on the I/O Link i screen.
When this alarm occurs on a well-worked machine, the cause may be the following.
Poor contact from (yy-1) slot to yy slot
Failure of module in yy slot or module in (yy-1) slot
If this alarm occurs during a debugging of sequence program, the following causes also come
up.
Wrong number of Slice I/O modules connected
Slice I/O allocation setting (number of slots) is incorrect
There is an error in the parameter setting of the I/O Link i assignment data selection
function.
Action
IOL0006
WRONG CONFIGURATION OF I/O MODULE (SLOT ID) (CHn GRxx SLyy)
The module type of the Slice I/O group set by the Slice I/O allocation and I/O Link i allocation
selection function parameters is different from the module type of the Slice I/O group actually
connected to the CNC. I/O units connected to all channels are not linked. The sequence
program is executed regardless of this alarm.
See details on the I/O Link i screen.
If this alarm occurs during a debugging of sequence program, the following causes also come
up.
Incorrect Slice I/O configuration (type, order) connected.
Slice I/O allocation settings (type, order) are incorrect.
There is an error in the parameter setting of the I/O Link i assignment data selection
function.
Number
Message
Contents
Action
IOL0101
I/O LINK I COMMUNICATION ERROR (CNC) (CHn)
The LSI for I/O Link i control is faulty.
Request hardware replacement.
Number
Message
Contents
Action
IOL0102
I/O LINK I COMMUNICATION ERROR (I/O UNIT) (CHn GRxx)
An I/O unit communication error occurred in the group xx of channel n.
Check the following.
Check the cable connections to the devices in group xx.
Check whether the power to each I/O unit has been turned on before the CNC.
Replace any device in group xx in which the PMC control module is embedded.
458
B-64805EN/03
Alarm list
If the group xx is a handy machine operator's panel, is there any error in the I/O Link i
allocation data?
Number
Message
Contents
Action
IOL0103
I/O LINK I COMMUNICATION ERROR (DCS)
The LSI for I/O Link i control for DCS is faulty.
Request hardware replacement.
Number
Message
Contents
Action
IOL0105
I/O LINK I TOO MANY CONNECTED GROUPS (CHn)
More than 25 I/O devices are connected.
The number of I/O devices to be connected should be 24 or less.
Number
Message
Contents
Action
IOL0106
I/O Link i TOO MANY SLOTS (CHn)
The number of I/O module slots to be connected is 257 or more.
Reduce the number of connected slots to 256 or less.
Number
Message
Contents
Action
IOL0107
I/O Link i STATUS ALARM LENGTH OVER IN GROUP (CHn GRxx)
The total status alarms of the I/O modules connected to the relevant group exceeds the 64byte limit.
Change the I/O configuration so that the total size of status alarms is 64 bytes or less.
Number
Message
Contents
Action
IOL1001
I/O LINK I ASSIGNMENT ERROR (DO SIZE) (CHn GRxx)
The number of output signals is exceeding the maximum value.
Reduce the number of output signals.
Number
Message
Contents
Action
IOL1002
I/O LINK I ASSIGNMENT ERROR (DI SIZE) (CHn GRxx)
The number of input signals is exceeding the maximum value.
Reduce the number of input signals.
Number
Message
Contents
Action
IOL1003
I/O LINK I ASSIGNMENT ERROR (SAFETY I/O GROUPS)
The number of safety I/O groups of DCSPMC1 or DCSPMC2 is exceeding 12 groups across all
channels in total.
Reduce the number of safety I/O groups.
Number
Message
Contents
Action
IOL1004
I/O LINK I ASSIGNMENT ERROR (HIGH SPEED MODE) (CHn GRxx)
The number of I/O points per one high-speed mode cycle (0.5 ms) exceeds the limit.
Reduce the number of I/O points per cycle.
Number
Message
Contents
Action
IOL1005
I/O LINK I ASSIGNMENT ERROR (ASSIGNED ADDRESS) (CHn GRxx)
I/O Link i assignment data is assigned an invalid PMC path address.
Modify I/O Link i assignment data.
Number
Message
IOL2001
I/O Link i ASSIGNMENT DATA ERROR (TOO LARGE SIZE)
459
Alarm list
B-64805EN/03
Contents
Action
I/O Link i assignment data is too large.
Reduce I/O Link i allocation data or request additional PMC program memory options.
Number
Message
Contents
Action
IOL2002
I/O LINK I ASSIGNMENT DATA ERROR (INVALID DATA)
Cannot recognize I/O Link i assignment data.
Input the correct I/O Link i assignment data.
Number
Message
Contents
Action
IOL2003
I/O Link i ASSIGNMENT DATA ERROR (CORRUPTION)
I/O Link i assignment data is broken.
Input the correct I/O Link i assignment data.
Number
Message
Contents
Action
IOL2004
I/O Link i ASSIGNMENT DATA ERROR (UNSUPPORTED)
The I/O Link i assignment data is using an unsupported function.
Do not use the function that is not supported or request CNC software version upgrade.
Number
Message
IOL3001
NETWORK DEVICE ASSIGNMENT AND I/O LINK I ASSIGNMENT OVERLAP
(PMCm %X/Ybbbb)
The X address or Y address assigned to the network device overlaps with the assigned data of
I/O Link i.
Change the assignment so that the assigned addresses of the network device and I/O Link i do
not overlap.
Contents
Action
Number
Message
Contents
Action
Number
Message
Description
Action
Number
Message
Description
Action
460
IOL9001
I/O LINK I UNIT ERROR (ABNORMAL OUTPUT) (CHn GRxx SLyy OFzz :
PMCm %Ybbbb=**H)
A status alarm (output error) has occurred in byte zz of slot yy of group xx of channel n. The
PMC address where DO was assigned and an alarm has occurred is indicated in
"PMCm %Ybbbb." "DCSPMC %Ybbbb" is displayed in the case of DCSPMC address. If an
error occurs at a DO that is not assigned, "PMC0 %Y0000" is displayed. **H indicates the bit
where the alarm is occurring in hexadecimal. The bit generating the alarm is 1.
(Example: "PMC1 Y115=28H" indicates that the DO alarm occurs at %Y115.3 and %Y115.5 in
PMC1. ("28H" means "00101000" in binary))
Check the DO for the relevant device. For details on alarm information for I/O units, refer to the
connection manual (hardware) or the connection manual of I/O units.
IOL9002
I/O LINK I UNIT ERROR (STATUS ALARM) (CHn GRxx SLyy OFzz=**H)
A status alarm has occurred at byte zz of slot yy of group xx of channel n. "**H" represents a
hexadecimal number that indicates the bit at which the alarm has occurred. The bit generating
the alarm is 1.
Check the alarm information for the relevant I/O unit. For details on alarm information for I/O
units, refer to the connection manual (hardware) or the connection manual of I/O units.
IOL9003
I/O LINK I UNIT ERROR (STATUS ALARM) (CHn GRxx SLyy OFzz=****H)
A status alarm has occurred at byte zz of slot yy of group xx of channel n. "**H" represents a
hexadecimal number that indicates the bit at which the alarm has occurred. The bit generating
the alarm is 1.
Check the alarm information for the relevant I/O unit. For details on alarm information for I/O
units, refer to the connection manual (hardware) or the connection manual of I/O units.
B-64805EN/03
Number
Message
Contents
Action
2.1.15.
Alarm list
IOL9011
I/O Link i ASSIGNMENT DATA ERROR (UNKNOWN DATA)
The I/O Link i assignment data contains unknown data.
Do not use the function that is not supported or request CNC software version upgrade.
Warning Alarms (WNG Alarm)
Number
Message
Contents
WNG10001
START FROM MIDDLE OF PROG (START/RESET)
Attempted to start automatic operation from the middle of the program.
To execute automatic operation from the middle of the program, turn the automatic
operation start signal on and then turn it off.
To perform automatic operation from the beginning of the program, rewind the program.
Number
Message
Contents
WNG10002
EXECUTING THIS BLOCK OK?(START/RESET)
Operation started with the start check signal set to "1".
Number
Message
Contents
WNG10003
START REJECTED (ALARM EXISTED)
Number
Message
Contents
WNG10004
START REJECTED (FEED HOLD ON)
Number
Message
Contents
WNG10005
START REJECTED (ALREADY EXECUTING)
Number
Message
Contents
WNG10006
THIS COMMAND CAN NOT EXECUTE
Number
Message
Contents
WNG10007
MODAL DATA IS CHANGED BY BLOCK STOP
Modal information has returned to the state before block execution by a reset.
Number
Message
Contents
WNG10008
MODE MISMATCH IN RESTART (START/RESET)
After operation was stopped, operation was resumed in a different mode.
Number
Message
Contents
WNG10010
CLOCK BATTERY IS LOW
The clock battery voltage is low.
Battery is not installed and bit 0 (BTC) of parameter No. 41700 is set to 0.
Number
Message
Contents
WNG10011
SV INTERNAL FAN ANOMALY
The rotation speed of the internal fan motor of the servo amplifier decreased.
461
Alarm list
B-64805EN/03
Action
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Number
Message
Contents
Action
WNG10012
SV EXTERNAL FAN ANOMALY
The rotation speed of the fan motor cooling the heat sink of the servo amplifier decreased.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Number
Message
Contents
WNG10013
PS INTERNAL FAN ANOMALY(SV)
A decrease in the speed of the internal fan motor of the common power supply was detected
on the servo axis.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Action
Number
Message
Contents
Action
WNG10014
PS EXTERNAL FAN ANOMALY(SV)
A decrease in the speed of the fan motor cooling the heat sink of the common power supply
was detected on the servo axis.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Number
Message
Contents
Action
WNG10015
SP INTERNAL FAN ANOMALY
The rotation speed of the internal fan motor of the spindle amplifier decreased.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Number
Message
Contents
Action
WNG10016
SP EXTERNAL FAN ANOMALY
The rotation speed of the fan motor cooling the heat sink of the spindle amplifier decreased.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Number
Message
Contents
WNG10017
PS INTERNAL FAN ANOMALY(SP)
A decrease in the speed of the internal fan motor of the common power supply was detected
on the spindle axis.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
462
WNG10018
PS EXTERNAL FAN ANOMALY(SP)
A decrease in the speed of the fan motor cooling the heat sink of the common power supply
was detected on the spindle axis.
The rotation speed of the fan motor has decreased, so replacement is recommended. Check
the Fan Monitor screen for details.
WNG10019
ABNORMAL INSULATION RESISTANCE(SV)
Insulation resistance of SV motor/power line has dropped.
Insulation resistance of SV motor/power line has dropped, so replacement is recommended.
Check Leakage detection monitor screen.
B-64805EN/03
Alarm list
Number
Message
Contents
Action
WNG10020
ABNORMAL INSULATION RESISTANCE(SP)
Insulation resistance of SP motor/power line has dropped.
Insulation resistance of SP motor/power line has dropped, so replacement is recommended.
Check Leakage detection monitor screen.
Number
Message
Contents
WNG10021
BRAKE TORQUE SHORTAGE
The gravity load torque ratio measured by the brake check has not reached the threshold value
(parameter No. 11591). The servomotor brake may be broken.
The servomotor brake may be broken.
Please check diagnosis No. 1850#0 and consider replacing the servo motor.
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
WNG10022
BRAKE RELEASE FAILURE
The machine friction torque ratio measured by the brake check has exceeded the threshold
value (parameter No. 11593).
Please check if the brake is energized.
If the power is turned on normally, check diagnosis No. 1850#2 and consider replacing the
servo motor.
WNG10023
BRAKE ACTUATION DELAY
The brake actuation time measured by the brake check has exceeded the threshold value
(parameter No. 11595).
The servomotor brake may be broken.
Please check diagnosis No.1850#4 and consider replacing the servo motor.
Number
Message
Contents
Action
WNG10024
AUX. MCR ABNORMAL END
Fatal error has occurred in the auxiliary macro that prevents execution from continuing.
The auxiliary macro program failure is detected.
After memorize the situation, please contact the machine tool builder.
Number
Message
Description
Action
WNG10029
START REJECTED (ALREADY EXECUTING MANUAL NUMERIC COMMAND)
An attempt was made to start automatic operation while executing a manual numeric
command.
Automatic operation cannot be started while executing a manual numeric command.
Number
Message
Description
Action
WNG10190
FAN ROTATION WARNING(FAN1)
The rotation speed of the fan is out of the normal range.
Replace FAN1.
Number
Message
Description
Action
WNG10191
FAN STARTUP WARNING(FAN1)
The rotation speed of the fan at start-up is out of the normal range.
Replace FAN1.
Number
Message
WNG10192
PLEASE PERFORM MCC SELF-TEST
463
Alarm list
B-64805EN/03
Contents
Action
PLEASE PERFORM MCC SELF-TEST
PLEASE PERFORM MCC SELF-TEST
Number
Message
Contents
Action
WNG10193
PLEASE PERFORM SAFE BRAKE TEST
PLEASE PERFORM SAFE BRAKE TEST
PLEASE PERFORM SAFE BRAKE TEST
Number
Message
Contents
Action
WNG10194
BRAKE TEST CANNOT BE PERFORMED
The brake test execution condition is not satisfied.
Please satisfy the brake test execution condition.
Number
Message
Contents
Action
WNG10195
PLEASE PERFORM SAFE DI UNIT TEST
PLEASE PERFORM SAFE DI UNIT TEST
PLEASE PERFORM SAFE DI UNIT TEST
Number
Message
Description
Action
WNG10196
FAN ROTATION WARNING(FAN2)
The rotation speed of the fan is out of the normal range.
Replace FAN2.
Number
Message
Description
Action
WNG10197
FAN STARTUP WARNING(FAN2)
The rotation speed of the fan at start-up is out of the normal range.
Replace FAN2.
Number
Message
Description
Action
WNG10198
FAN ROTATION WARNING(FAN3)
The rotation speed of the fan is out of the normal range.
Replace FAN3.
Number
Message
Description
Action
WNG10199
FAN STARTUP WARNING(FAN3)
The rotation speed of the fan at start-up is out of the normal range.
Replace FAN3.
Number
Message
Description
Action
WNG10200
FAN ROTATION WARNING(FAN4)
The rotation speed of the fan is out of the normal range.
Replace FAN4.
Number
Message
Description
Action
WNG10201
FAN STARTUP WARNING(FAN4)
The rotation speed of the fan at start-up is out of the normal range.
Replace FAN4.
464
B-64805EN/03
2.2.
Alarm list
Alarm List (Spindle)
When a spindle alarm occurs, it is displayed with the following number on the CNC.
NOTE
For information about spindle alarm numbers that are not listed below, refer to the following documents according
to the actual spindle motor to be connected.
"SERVO MOTOR αi-D series, SPINDLE MOTOR αi-D series, SERVO AMPLIFIER αi-D series
MAINTENANCE MANUAL" (B-65555EN)
Technical reports, etc.
Number
Message
SP
Displ
ay*1
Check the ambient
MOTOR OVERHEAT
MOTOR OVERHEAT
SP9001
01
SP9003
SP9004
SP9006
02
DC-LINK FUSE IS
BROKEN
DC-LINK FUSE IS
BROKEN
PS IMPROPER INPUT
POWER
PS IMPROPER INPUT
POWER
THERMAL SENSOR
DISCONNECT
THERMAL SENSOR
DISCONNECT
OVER SPEED
OVER SPEED
SP9007
SP9009
SP9010
SP IMPROPER
CONTROL VOLTAGE
SP IMPROPER
CONTROL VOLTAGE
cutting conditions to lower
the load.
Modify the setting of
parameter No. 4082.
Replace the spindle
amplifier (SP).
Check the insulation of the
03
-
motor.
Check the input power to the
power supply (PS).
Check and modify the
06
07
OVERHEAT MAIN
CIRCUIT
OVERHEAT MAIN
CIRCUIT
temperature and load
conditions.
If the cooling fan has
stopped, replace it.
Check and correct the
EX DEVIATION SPEED
EX DEVIATION SPEED
SP9002
Faulty location / corrective
action
parameter settings.
Replace the feedback
cable.
Check for errors in the sequence
(such as spindle synchronization
commanded when the spindle
cannot rotate).
Improve the heat sink
cooling status.
09
10
If the heat sink cooling fan
has stopped, replace the
spindle amplifier (SP).
Check the output voltage of
the control power supply
(24 VDC).
Check the cable
connections.
Contents
The inside of the motor is above the
specified temperature.
The internal temperature of the
motor exceeds the continuous rating
or a cooling anomaly occurs.
The motor speed cannot follow a
specified speed.
An excessive motor load torque is
detected.
The acceleration/deceleration time
in parameter No. 4082 is
insufficient.
The power supply (PS) becomes
ready (with "0" displayed), but the
DC link voltage is too low in the
spindle amplifier (SP).
The fuse in the DC link section
inside the SP is blown (due to
power device damage or motor
ground fault).
Power abnormality is detected by
the power supply (PS) (power
supply alarm indication of "14").
The temperature sensor of the
motor is disconnected.
The motor speed has exceeded
115% of its rated speed.
When the spindle axis was in
position control mode, position error
were accumulated excessively (for
example, SFR and SRV were
turned off during spindle
synchronization.)
The temperature in the power
semiconductor cooling radiator is
abnormally high.
Abnormality is detected in the
control power supply (24 VDC) of
the spindle amplifier (SP).
465
Alarm list
Number
B-64805EN/03
Message
SP
Displ
ay*1
Faulty location / corrective
action
Contents
Replace the spindle
amplifier (SP).
Check if a proper power
PS OVER VOLT. DC
LINK
PS OVER VOLT. DC
LINK
SP9011
SP9012
-
OVERCURRENT
POWER CIRCUIT
OVERCURRENT
POWER CIRCUIT
12
CPU DATA MEMORY
FAULT
SP9013
SP9014
SP9015
SP9016
SP9017
SP9018
SP9019
SP9020
SP9021
466
13
SOFTWARE SERIES
MISMATCH
SOFTWARE SERIES
MISMATCH
SPINDLE SWITCHING
FAULT
SPINDLE SWITCHING
FAULT
RAM ERROR
RAM ERROR
ID NUMBER PARITY
ERROR
ID NUMBER PARITY
ERROR
SUMCHECK ERROR
PROGRAM ROM
SUMCHECK ERROR
PROGRAM ROM
EXCESS OFFSET
CURRENT U
EXCESS OFFSET
CURRENT U
EXCESS OFFSET
CURRENT V
EXCESS OFFSET
CURRENT V
POS SENSOR
POLARITY ERROR
POS SENSOR
POLARITY ERROR
14
supply (PS) is selected.
Check the input power
voltage and change in
power during motor
deceleration. If the voltage
exceeds 253 VAC (for the
200-V system) or 530 VAC
(for the 400-V system),
improve the power supply
impedance.
Check the insulation of the
motor.
Check the spindle
parameters.
Replace the spindle
amplifier (SP).
Replace the spindle amplifier
(SP) control printed circuit
board.
Replace the spindle amplifier
(SP).
Check and correct the
15
16
17
18
19
20
21
ladder sequence.
Replace the switching
MCC.
Replace the spindle amplifier
(SP) control printed circuit
board.
Replace the spindle amplifier
(SP).
Overcurrent is detected in the DC
link section of the power supply
(PS) (power supply alarm indication
of "07").
Improper PS is selected. (The
maximum PS output specification is
exceeded.)
The motor current is abnormally
high.
A motor-specific parameter does not
match the motor model.
Poor motor insulation
Abnormality in a spindle amplifier
(SP) control circuit component is
detected. (Abnormality in the RAM
within the spindle amplifier (SP) is
detected.)
The mismatch of the spindle
software and a spindle amplifier
(SP) is detected.
The switch sequence in spindle
switching/speed range switching
operation is abnormal.
The switching MCC contact status
check signal and command do not
match.
Abnormality in a spindle amplifier
(SP) control circuit component is
detected. (Abnormality in the RAM
for data is detected.)
Abnormality in spindle amplifier (SP)
ID data is detected.
Replace the spindle amplifier
(SP) control printed circuit
board.
Abnormality in a spindle amplifier
(SP) control circuit component is
detected. (Abnormality in the
program ROM data is detected.)
Replace the spindle amplifier
(SP).
Abnormality in a spindle amplifier
(SP) component is detected. (The
initial value for the U phase current
detection circuit is abnormal.)
Replace the spindle amplifier
(SP).
Abnormality in a Spindle Amplifier
(SP) component is detected. (The
initial value of the V phase current
detection circuit is abnormal.)
Check and correct the settings
of parameters No. 4000#0 and
4001#4.
The polarity parameter setting of the
position sensor is wrong.
B-64805EN/03
Number
SP9022
SP9024
SP9027
Alarm list
Message
SP AMP OVER
CURRENT
SP AMP OVER
CURRENT
SERIAL TRANSFER
ERROR
SERIAL TRANSFER
ERROR
DISCONNECT
POSITION CODER
DISCONNECT
POSITION CODER
OVERLOAD
OVERLOAD
SP9029
SP
Displ
ay*1
Review operation
22
24
27
Check and correct the load
condition.
29
SP9030
Check and correct the power
supply voltage.
-
MOTOR LOCK
MOTOR LOCK
Check and correct the load
31
SIC-LSI RAM FAULT
SIC-LSI RAM FAULT
SP9032
SP9033
32
PS PRE-CHARGE
FAILURE
PS PRE-CHARGE
FAILURE
SP9034
cable (JYA2).
Replace the spindle amplifier
(SP) control printed circuit
board.
power supply voltage.
Replace the power supply
-
34
OVERFLOW ERROR
COUNTER
OVERFLOW ERROR
COUNTER
condition.
Replace the motor sensor
Check and correct the
ILLEGAL PARAMETER
ILLEGAL PARAMETER
SP9036
conditions (acceleration/
deceleration and cutting) to
reduce the load.
Check and modify the
parameter settings.
Place the CNC-to-spindle
cable away from the power
cable.
Replace the cable.
Replace the cable.
OVERCURRENT
PS OVERCURRENT
SP9031
Faulty location / corrective
action
36
(PS).
See "SPINDLE MOTOR αi-D/αiB/αi series, AC SPINDLE
MOTOR βi-B/βi series, BUILTIN SPINDLE MOTOR Bi-B/Bi
series SPINDLE PARAMETER
MANUAL" (B-65280EN) to
correct the parameter value.
If the parameter number is
unknown, connect the spindle
check board, and check the
indicated parameter.
Check whether the position gain
value is too large, and correct
the value.
Contents
A spindle amplifier (SP) overload
current is detected.
The CNC power is turned off
(normal power-off or broken cable).
An error is detected in
communication data transferred to
the CNC.
The spindle position coder
(connector JYA3) signal is
abnormal.
Excessive load is continuously
applied for a certain period of time.
(This alarm also occurs when the
motor shaft is restrained in the
excited state.)
Overcurrent is detected in the power
supply (PS) main circuit input
(power supply alarm indication of
"01").
Unbalanced power supply.
Improper PS is selected. (The
maximum PS output specification is
exceeded.)
The motor cannot rotate at the
commanded speed. (The motor is
rotating at speeds below the SST
level).
Abnormality in a spindle amplifier
(SP) control circuit component is
detected. (Abnormality in the LSI
device for serial transfer is
detected.)
The DC power supply voltage of the
power circuit section is not
sufficiently charged when the
magnetic contactor is turned on
(power supply alarm indication of
"05") (due to missing phase, poor
charging resistance, etc.).
Parameter data exceeding the
allowable limit is set.
An error counter overflow occurred.
467
Alarm list
Number
SP9037
SP9041
SP9042
SP9043
SP9046
SP9047
SP9049
SP9050
SP9051
B-64805EN/03
Message
ILLEGAL SETTING
VELOCITY
DETECTOR
ILLEGAL SETTING
VELOCITY
DETECTOR
ILLEGAL 1REV SIGN
OF POSITION CODER
ILLEGAL 1REV SIGN
OF POSITION CODER
NO 1REV SIGN OF
POSITION CODER
NO 1REV SIGN OF
POSITION CODER
DISCONNECT
POSITION CODER
DEF. SPEED
DISCONNECT
POSITION CODER
DEF. SPEED
ILLEGAL 1REV SIGN
OF SCREW CUT
ILLEGAL 1REV SIGN
OF SCREW CUT
ILLEGAL SIGNAL OF
POSITION CODER
ILLEGAL SIGNAL OF
POSITION CODER
DEF. SPEED IS OVER
VALUE
DEF. SPEED IS OVER
VALUE
SYNCRONOUS
VALUE IS OVER
SPEED
SYNCRONOUS
VALUE IS OVER
SPEED
PS LOW VOLT. DC
LINK
PS LOW VOLT. DC
LINK
SP
Displ
ay*1
37
41
42
Replace the cable.
43
Check and modify the
46
SP9053
468
47
49
50
parameter settings.
Replace the cable.
Readjust the BZ sensor
signal.
Replace the cable.
Correct the cable layout
(vicinity to the power line).
Check that the calculated value
of the differential speed does not
exceed the maximum rotation
speed of the motor.
Check that the calculated value
does not exceed the maximum
rotation speed of the motor.
Check and correct the
-
power supply voltage.
Replace the MC.
Replace the spindle
52
ITP FAULT 2
ITP FAULT 2
See "SPINDLE MOTOR αi-D/αiB/αi series, AC SPINDLE
MOTOR βi-B/βi series, BUILTIN SPINDLE MOTOR Bi-B/Bi
series SPINDLE PARAMETER
MANUAL" (B-65280EN) to
correct the parameter value.
Check and modify the
parameter settings.
Replace the cable.
Replace the cable.
ITP FAULT 1
ITP FAULT 1
SP9052
Faulty location / corrective
action
53
amplifier (SP) control
printed circuit board.
Replace the main board or
additional spindle board on
the CNC.
Replace the spindle
amplifier (SP) control
printed circuit board.
Contents
The setting of the parameter for the
number of pulses in the speed
detector is incorrect.
The 1-rotation signal of the
spindle position coder
(connector JYA3) is abnormal.
A parameter setting error is
detected.
The 1-rotation signal of the spindle
position coder (connector JYA3) is
disconnected.
The position coder signal (connector
JYA3S) for differential speed in the
submodule SW is abnormal.
The 1-rotation signal in threading is
abnormal.
The A/B phase signal of the spindle
position coder (connector JYA3) is
abnormal.
The relationship between the A/B
phase and 1-rotation signal is
incorrect (Pulse count mismatch).
In differential speed mode, the value
obtained by converting the pair's
speed into your speed exceeds the
allowable value (the differential
speed is calculated by multiplying
the pair's speed by the gear ratio).
In spindle synchronous control, the
calculated value of the speed
command exceeded the allowable
value (the motor speed is calculated
by multiplying the spindle rotation
command by the gear ratio).
Input voltage drop is detected
(power supply (PS) alarm indication
of "04").
(Momentary power failure or poor
MCC contact)
An abnormality is detected in the
interface between the CNC and
spindle amplifier (the ITP signal
stopped).
An abnormality is detected in the
interface between the CNC and
spindle amplifier (the ITP signal
stopped).
B-64805EN/03
Number
Alarm list
Message
SP
Displ
ay*1
Faulty location / corrective
action
Contents
Replace the main board or
SP9054
SP9055
SP9056
OVERCURRENT
OVERCURRENT
ILLEGAL POWER LINE
ILLEGAL POWER LINE
COOLING FAN
FAILURE
COOLING FAN
FAILURE
PS EXCESSREGENERATION2
PS EXCESSREGENERATION2
SP9057
SP9058
SP9059
SP9061
SP9065
SP9066
SP9067
SP9068
SP9069
54
Replace the magnetic
55
56
PS INTERNAL FAN
FAILURE
PS INTERNAL FAN
FAILURE
SEMI-FULL ERROR
EXCESS
SEMI-FULL ERROR
EXCESS
SERIAL SPINDLE
ALARM
SERIAL SPINDLE
ALARM
COM. ERROR
BETWEEN SP AMPS
COM. ERROR
BETWEEN SP AMPS
FSC/EGB COMMAND
ERROR
FSC/EGB COMMAND
ERROR
INCORRECT
PARAMETER
INCORRECT
PARAMETER
SAFETY SPEED OVER
SAFETY SPEED OVER
contactor.
Check and correct the
sequence.
Replace the internal agitating
fan.
Decrease the
-
PS OVERLOAD
PS OVERLOAD
additional spindle board on
the CNC.
Check the load conditions.
-
acceleration/deceleration
duty.
Check the cooling
conditions (ambient
temperature).
If the cooling fan stops,
replace the resistor.
If the resistance value is
abnormal, replace the
resistor.
Check the power supply
(PS) cooling status.
Replace the power supply
(PS).
Replace the power supply (PS).
-
67
68
The temperature of the radiator of
the power supply (PS) has
increased abnormally (power supply
alarm indication of "03").
The internal cooling fan of the
power supply (PS) has stopped
(power supply alarm indication of
"02").
Check the parameter
The move distance is too long when
the magnetic pole is confirmed.
(synchronous spindle motor)
settings.
Check the sensor
connections and signals.
Check the power line
connection.
Replace the cable.
Check and correct the
connection.
An error is detected in
communication (via connector JX4)
between spindle amplifiers (SPs).
Check the sequence (reference
position return command).
In the spindle EGB mode, reference
position return was specified.
Check the spindle state error
number (Diagnosis No.710) and
correct the corresponding
parameter.
An incorrect parameter setting is
found.
Check the commanded
69
An overload is detected in the
regenerative resistance (power
supply alarm indication of "16").
Thermostat operation or short-time
overload is detected.
The regenerative resistor is
disconnected, or an abnormal
resistance is detected.
The error between the semi-closed
and full-closed sides when the dual
position feedback function is used is
too large.
66
The power line state signal of the
magnetic contactor for spindle
switching/speed range switching is
abnormal.
The internal agitating fan has
stopped.
Check the parameter settings.
61
65
An overload current is detected.
speed.
Check the parameter
settings.
Check the sequence.
In the state in which safety speed
monitoring was enabled, the system
detected that the motor speed
exceeded the safety speed or
469
Alarm list
Number
B-64805EN/03
Message
SP
Displ
ay*1
ILLEGAL AXIS DATA
ILLEGAL AXIS DATA
SP9070
SP9071
SP9072
SP9073
70
SAFETY PARAMETER
ERROR
SAFETY PARAMETER
ERROR
MISMATCH RESULT
OF MOTOR SPEED
CHECK
MOTOR SENSOR
DISCONNECTED
MOTOR SENSOR
DISCONNECTED
71
72
73
SP9074
CPU TEST ERROR
CPU TEST ERROR
74
SP9075
CRC ERROR
CRC ERROR
75
SP9076
INEXECUTION OF
SAFETY FUNCTIONS
76
SP9077
SP9078
MISMATCH RESULT
OF AXIS NUMBER
CHECK
MISMATCH RESULT
OF SAFETY
PARAMETER CHECK
77
78
INITIAL TEST ERROR
SP9079
SP9080
470
79
ALARM AT THE
OTHER SP AMP.
80
Faulty location / corrective
action
Contents
When this alarm is issued
detected an error during a free-run
stop.
An error was detected during
transmission of axis data of a
spindle.
because the configuration
of the spindle amplifiers
(SPs) was changed, set the
spindle number for the
spindle amplifier (bit 7 of
parameter No. 4541 to 1
and then 0, and turn the
power to the entire system
off).
Replace the spindle
amplifier.
Input the safety parameter
again.
Replace the spindle
amplifier (SP) control
printed circuit board.
Replace the spindle
amplifier (SP) control
printed circuit board.
Replace the main board or
additional spindle board on
the CNC.
Replace the feedback
cable.
Check the shielding.
Check and correct the
connection.
Adjust the sensor.
Replace the spindle amplifier
(SP) control printed circuit
board.
Replace the spindle amplifier
(SP) control printed circuit
board.
Replace the spindle amplifier
(SP) control printed circuit
board.
Replace the spindle
amplifier (SP) control
printed circuit board.
Replace the main board or
additional spindle board on
the CNC.
Replace the spindle
amplifier (SP) control
printed circuit board.
Replace the main board or
additional spindle board on
the CNC.
Replace the spindle amplifier
(SP) control printed circuit
board.
Remove the cause of the alarm
of the remote spindle amplifier
(SP).
An error was detected during safety
parameter check.
A mismatch was detected between
the safety speed check results of
the spindle amplifier (SP) and those
of the CNC.
The motor sensor feedback signal is
not present (connector JYA2).
An error was detected in a CPU
test.
An error was detected in a ROM
CRC test.
The spindle amplifier (SP) detected
that the safety function was not
executed.
A mismatch was detected between
the axis number check results of the
spindle amplifier (SP) and those of
the CNC.
The result of a safety parameter
check by the spindle amplifier (SP)
conflicts with that of a safety
parameter check by the CNC.
An error was detected in an initial
test operation for the spindle
amplifier (SP).
During inter-spindle amplifier (SP)
communication, an alarm was
generated on the remote spindle
amplifier (SP).
B-64805EN/03
Alarm list
Number
Message
SP9081
1-ROT MOTOR
SENSOR ERROR
1-ROT MOTOR
SENSOR ERROR
SP9082
SP9083
SP9084
NO 1-ROT MOTOR
SENSOR
NO 1-ROT MOTOR
SENSOR
MOTOR SENSOR
SIGNAL ERROR
MOTOR SENSOR
SIGNAL ERROR
SPNDL SENSOR
DISCONNECTED
SPNDL SENSOR
DISCONNECTED
SP
Displ
ay*1
Faulty location / corrective
action
Check and modify the
81
82
Replace the feedback
83
cable.
Adjust the sensor.
Replace the feedback
84
SP9085
SP9086
SP9087
SP9088
1-ROT SPNDL
SENSOR ERROR
1-ROT SPNDL
SENSOR ERROR
NO 1-ROT SPNDL
SENSOR
NO 1-ROT SPNDL
SENSOR
SPNDL SENSOR
SIGNAL ERROR
SPNDL SENSOR
SIGNAL ERROR
COOLING RADI FAN
FAILURE
COOLING RADI FAN
FAILURE
SUB MODULE SM
(SSM) ERROR
SUB MODULE
SM(SSM)ERROR
SP9089
SP9090
SP9091
SP9092
85
POLE POSITION
COUNT MISS
POLE POSITION
COUNT MISS
OVER SPEED TO
VELOCITY COMMAND
86
cable.
Check the shielding.
Check and correct the
connection.
Check and modify the
parameter settings.
Adjust the sensor.
Check and modify the
parameter settings.
Replace the feedback
cable.
Adjust the sensor.
Replace the feedback
cable.
Adjust the sensor.
Replace the feedback
87
88
89
UNEXPECTED
ROTATION
UNEXPECTED
ROTATION
parameter settings.
Replace the feedback
cable.
Adjust the sensor.
Replace the feedback
cable.
Adjust the sensor.
90
cable.
Adjust the sensor.
The one-rotation signal of the motor
sensor cannot be correctly detected.
(connector JYA2)
The one-rotation signal of the motor
sensor is not generated. (connector
JYA2)
An irregularity was detected in a
motor sensor feedback signal.
(connector JYA2)
The spindle sensor feedback signal
is not present. (connector JYA4)
The one-rotation signal of the
spindle sensor cannot be correctly
detected. (connector JYA4)
The one-rotation signal of the
spindle sensor is not generated.
(connector JYA4)
An irregularity was detected in a
spindle sensor feedback signal.
(connector JYA4)
Replace the spindle amplifier
(SP) radiator cooling fan.
The radiator cooling fan has
stopped.
Check the connection
Submodule SM (SSM) error
(synchronous spindle motor).
between the spindle
amplifier (SP) and the
submodule SM (SSM).
Replace the submodule SM
(SSM).
Replace the spindle
amplifier (SP) control
printed circuit board.
Check the magnetic pole
detection operation.
Check that the rotor and
sensor are aligned
correctly.
Replace the motor sensor cable.
91
Check and correct the
92
Contents
parameter (the number of
Unexpected rotation of the
synchronous spindle motor was
detected.
Count error of the magnetic pole
position of the synchronous spindle
motor.
The motor speed exceeds the
overspeed level corresponding to
the velocity command.
471
Alarm list
Number
B-64805EN/03
Message
SP
Displ
ay*1
Faulty location / corrective
action
OVER SPEED TO
VELOCITY COMMAND
SP9093
SP9110
SP9111
SP9112
SP9113
SP9114
SP9115
SPINDLE SENSOR
ERROR
SPINDLE SENSOR
ERROR
AMP
COMMUNICATION
ERROR
AMP
COMMUNICATION
ERROR
PS IMPROPER
CONTROL VOLTAGE
PS IMPROPER
CONTROL VOLTAGE
PS EXCESSREGENERATION1
PS EXCESSREGENERATION1
PS EXTERNAL FAN
FAILURE
PS EXTERNAL FAN
FAILURE
PS CONTROL AXIS
ERROR 1
PS CONTROL AXIS
ERROR 1
PS CONTROL AXIS
ERROR 2
PS CONTROL AXIS
ERROR 2
COMMUNICATION
DATA ERROR
COMMUNICATION
DATA ERROR
SP9120
93
Replace the
b0
-
-
-
communication cable
between the amplifiers.
Replace the spindle
amplifier (SP) or power
supply (PS) control printed
circuit board.
Check the output voltage of
the control power supply
(24 VDC).
Check the cable
connections.
Replace the power supply
(PS).
Check the regenerative
resistor connection.
Check if a proper motor is
selected.
Replace the power supply
(PS).
Replace the external radiator
cooling fan for power supply
(PS).
Set parameter No. 4657 to 0.
b5
Set parameter No. 4657 to a
value other than 0.
Replace the
SP9121
472
The rate of change in the amplitude
of the phase A signal / phase B
signal (sine wave) of the spindle
sensor output exceeds the
evaluation level set in the
parameter.
Communication error between
spindle amplifier (SP) and power
supply (PS).
Abnormality is detected in the
control power supply (24 VDC) of
the power supply (PS) (power
supply alarm indication of "06").
Excessive converter regenerative
power (power supply alarm
indication of "08").
Stopped the external radiator
cooling fan for Power Supply (PS)
(power supply alarm indication of
"10")
Invalid parameter
b4
C0
COMMUNICATION
DATA ERROR
COMMUNICATION
DATA ERROR
motor sensor teeth and
poles).
Take measures against
noise.
Replace the sensor.
Adjust the sensor.
Check and correct the
setting of parameter No.
4574.
Replace the sensor.
Contents
C1
communication cable
between the CNC and
spindle amplifier (SP).
Replace the spindle
amplifier (SP) control
printed circuit board.
Replace the main board or
additional spindle board on
the CNC.
Replace the
communication cable
between the CNC and
spindle amplifier (SP).
Replace the SP control
printed circuit board.
Invalid parameter
Communication data alarm.
Communication data alarm.
B-64805EN/03
Number
Alarm list
Message
SP
Displ
ay*1
Faulty location / corrective
action
Contents
Replace the main board or
COMMUNICATION
DATA ERROR
COMMUNICATION
DATA ERROR
SP9122
C2
SP9128
SPINDLE SWITCH
CIRCUIT ERROR
SPINDLE SWITCH
CIRCUIT ERROR
LEARNING CTRL
ROTATION CMD
ERROR
LEARNING CTRL
ROTATION CMD
ERROR
LEARNING CTRL
COMP ORDER
ERROR
LEARNING CTRL
COMP ORDER
ERROR
LEARNING CTRL
PERIOD ERROR
LEARNING CTRL
PERIOD ERROR
SP SYNC VELOCITY
ERROR EXCESS
SP SYNC VELOCITY
ERROR EXCESS
SP9129
SP SYNC POSITION
ERROR EXCESS
SP SYNC POSITION
ERROR EXCESS
SP9123
SP9124
SP9125
SP9127
SP9130
SP9131
SP9132
TORQUE TANDEM
POLARITY ERROR
TORQUE TANDEM
POLARITY ERROR
SPINDLE TUNING
FUNCTION ALARM
SPINDLE TUNING
FUNCTION ALARM
SER.SENSOR DATA
ERROR
C3
additional spindle board on
the CNC.
Replace the
communication cable
between the CNC and
spindle amplifier (SP).
Replace the spindle
amplifier (SP) control
printed circuit board.
Replace the main board or
additional spindle board on
the CNC.
Replace the submodule SW
(SSW).
Correct the speed
Communication data alarm.
Submodule SW (SSW) error
(spindle switching).
A velocity that could not be used for
learning control was specified in
time-based learning control.
C4
command.
Correct the setting of the
learning period parameter
(No. 4425).
C5
Correct the settings of the
parameters for the maximum
and minimum orders of dynamic
characteristic compensation
elements for learning control
(Nos. 4427 and 4428).
An order outside the allowable
range was specified for dynamic
characteristic compensation
elements.
C7
Correct the setting of the
parameter for the number of
divisions per period for learning
control (No. 4425).
In angle-based learning control, the
reference angle period is invalid.
Check the sequence
C8
C9
d0
d1
(whether SFR or SRV is
turned off or on during
position control).
Check and correct the load
condition.
Check the parameter
settings.
Check the sequence
(whether SFR or SRV is
turned off or on during
position control). )
Check and correct the load
condition.
Check the parameter
settings.
Check the setting of the
parameter for the rotation
direction (bit 2 of No. 4353).
Check the message displayed
by SERVO GUIDE.
Replace the feedback
d2
cable.
Replace the sensor.
In spindle synchronous control,
velocity error exceeded the setting.
In spindle synchronous control,
position error exceeded the setting.
In tandem control, the rotation
directions of the master and slave
motors are invalid.
Spindle tuning function alarm.
Serial data error between a serial
sensor and spindle amplifier (SP).
473
Alarm list
Number
SP9133
SP9134
SP9135
SP9136
SP9137
SP9138
SP9139
SP9140
SP9141
SP9142
SP9143
SP9144
SP9145
474
B-64805EN/03
Message
SER.SENSOR DATA
ERROR
SER.SENSOR
TRANSFER ERROR
SER.SENSOR
TRANSFER ERROR
SER.SENSOR SOFT
PHASE ERROR
SER.SENSOR SOFT
PHASE ERROR
SAFETY SPEED ZERO
ERROR(SP)
MISMATCH RESULT
OF SAFETY SPEED
ZERO CHECK(SP)
MISMATCH RESULT
OF SAFETY SPEED
ZERO CHECK(SP)
SP DEVICE
COMMUNICATION
ERROR
SP DEVICE
COMMUNICATION
ERROR
CURRENT LIMIT
SETTING ERROR
CURRENT LIMIT
SETTING ERROR
SER.SENSOR PULSE
MISS
SER.SENSOR PULSE
MISS
SER.SENSOR COUNT
MISS
SER.SENSOR COUNT
MISS
SER.SENSOR NO 1ROT SIGNAL
SER.SENSOR NO 1ROT SIGNAL
SER.SENSOR
ABNORMAL
SER.SENSOR
ABNORMAL
CS HIGH SPEED
CHANGE CMD
ERROR
CS HIGH SPEED
CHANGE CMD
ERROR
CURRENT DETECT
CIRCUIT ERROR
CURRENT DETECT
CIRCUIT ERROR
LOW VOLTAGE
DRIVER
SP
Displ
ay*1
Faulty location / corrective
action
Contents
Replace the spindle
amplifier (SP).
Replace the feedback
d3
d4
d5
d6
d7
cable.
Replace the sensor.
Replace the spindle
amplifier (SP).
Check and correct the
sensor parameter setting.
Take measures against
noise.
Replace the sensor.
Perform operation within the
safety speed zero range.
Replace the spindle amplifier
(SP) control printed circuit
board.
The motor position exceeded the
safety speed zero monitoring range.
The spindle amplifier (SP) speed
zero determination result did not
match the CNC speed zero
determination result.
Device communication error in the
spindle amplifier (SP).
Check the parameters.
The current limit level setting is out
of the specified range.
Replace the sensor.
An error occurred in the serial
sensor interpolation circuit.
d9
Take measures against
noise.
Replace the sensor.
Check and correct the
E1
The change in serial sensor
positional data is too large.
Replace the spindle amplifier
(SP) control printed circuit
board.
d8
E0
Serial data error between a serial
sensor and spindle amplifier (SP).
sensor parameter setting.
Replace the sensor.
The number of feedback pulses per
one-rotation signal of the serial
sensor is outside the specified
range.
The serial sensor is not placed in
the status in which the one-rotation
signal has been detected.
Replace the sensor.
A serial sensor error occurred.
Check the sequence.
A command was issued though the
one-rotation signal had not been
detected.
Replace the spindle amplifier
(SP).
An error was found in the current
detection circuit.
Replace the spindle amplifier
(SP).
The driver circuit voltage has
dropped.
E2
E3
E4
E5
B-64805EN/03
Number
SP9148
SP9149
SP9150
SP9151
SP9152
SP9153
Alarm list
Message
LOW VOLTAGE
DRIVER
AXIS NUMBER NOT
SET
AXIS NUMBER NOT
SET
EXT. CURRENT FB UOFFST
EXT.CURRENT FB UOFFSET
EXT. CURRENT FB VOFFST
EXT.CURRENT FB VOFFSET
FILTER MODULE
ERROR
FILTER MODULE
ERROR
EXT.CUR.FB
DISCONNECT
EXT.CUR.FB
DISCONNECT
SP NO FAILURE
SP NO FAILURE
SP
Displ
ay*1
E8
Faulty location / corrective
action
Contents
Power off and on the CNC and
amplifiers.
The axis number of the spindle (SP)
is not set.
Replace the external
E9
current sensor.
Replace the spindle
amplifier (SP).
Replace the external
F0
current sensor.
Replace the spindle
amplifier (SP).
Replace the filter module.
External current sensor error.
Spindle amplifier (SP) error.
External current sensor error.
Spindle amplifier (SP) error.
A filter module error is detected.
F1
Replace the feedback
F2
F3
cable.
Replace the external
current sensor.
Check the machine.
Check and replace the
External current sensor error.
Failure of feedback cable
Control error
MCC.
Check and correct the
PHASE OPEN
PHASE OPEN
SP9154
SP9155
SP9156
SP9157
SP9158
SP9159
SP9160
SP9161
F4
FAILURE OF
SP(OPEN)
FAILURE OF
SP(OPEN)
Failure of current
control.
FAILURE OF
CURRENT CTRL.
FAILURE OF SP
(SHORT)
FAILURE OF SP
(SHORT)
MODE
DETERMINATION
MISMATCH
MISMATCHED
FUNCTION CODE
MISMATCHED
FUNCTION CODE
THERMISTOR
DISCONNECTION
THERMISTOR
DISCONNECTION
MOTOR POWER LINE
SHORT-CIRCUITED
POW. CABLE SHORT
CIRCUIT
F5
F6
F7
F8
power line connection.
Check and replace the
MCC.
Replace the motor.
Replace the spindle amplifier
(SP).
Failure of current control.
Replace the spindle amplifier
(SP).
Spindle amplifier (SP) failure.
Replace the CPU card on the
NC or the spindle amplifier (SP).
Mismatch of acceptance mode
setting of NC and mode state of
spindle amplifier (SP).
CNC, SV, SP, or PS software has
been updated.
F9
Replace the spindle amplifier
(SP).
Check and correct the
G1
Abnormality in spindle amplifier (SP)
is detected.
Make a service call after
memorizing the operation during
which the alarm occurred and
saving parameters.
Power off and restart the CNC.
G0
Disconnection of power cable.
Failure of MCC.
Disconnection of Motor windings.
power line connection.
Check and replace the
MCC.
Replace the motor.
Disconnection of thermistor wire for
temperature detection of spindle
amplifier (SP)
Short of power cable.
Failure of MCC.
Short of Motor windings.
475
Alarm list
Number
SP9162
SP9163
SP9164
SP9165
B-64805EN/03
Message
DELAY OFSP
POSITION DATA
TRANSMISSION
DELAY OF SP POS.
DATA
SP POSITION DATA
ERROR
ILLEGAL SP POS.
DATA
SENSOR SIGNAL
ERROR OF MASTER
AXIS
FAILURE OF MASTER
SENSOR
CHANGE OF
CONTROL SYSTEM
CONTROL METHOD
CHANGED
EXCESS ERROR
(GUIDE BUSH)
SP9166
SP9167
SP9168
G2
G3
G4
G5
FAILURE OF SP
CONTROL
SEQUENCE
FAILURE OF SP
CONTROL
SEQUENCE
COUPLING FAILURE
BETWEEN SPINDLE
AND SPINDLE MOTOR
INTERCEPTION
CIRCUIT FAILURE
(STO)
G7
G8
G9
EXCESS ERROR AT
STOP (SMART RIGID
TAPPING)
H0
SP9171
COOLING FAN
MOTOR STOP
COOLING FAN
MOTOR STOP
H1
SP9176
HPM OVERHEAT
HPM OVERHEAT
H6
SERIAL SENSOR
PHASE ALARM (PHAL)
SERIAL SENSOR
PHASE ALARM (PHAL)
H7
SP9177
476
Faulty location / corrective
action
Contents
Make a service call after
memorizing the operation during
which the alarm occurred and
saving parameters.
Failure of spindle position data
transmission.
Make a service call after
memorizing the operation during
which the alarm occurred and
saving parameters.
Failure of spindle position data
update.
Refer to the faulty location and
remedy of SP9083 for the input
(JYA4) of sensor signal of
master axis.
Failure of sensor signal of master
axis into slave axis.
Power off and on the CNC and
amplifiers.
Change of No.4000#7 setting.
Check the operating
G6
SP9169
SP9170
SP
Displ
ay*1
conditions.
Replace the spindle
amplifier (SP).
Replace the power line or
spindle motor.
Check the spindle state error
number (Diagnosis No.710) and
correct the corresponding ladder
sequence.
Check the combination between
the spindle and the spindle
motor.
Check the setting switch
and parameter settings.
Check the STO input cable.
Correct the STO input
timing.
Replace the spindle
amplifier (SP).
Check external equipment.
Make a service call after
memorizing the operation during
which the alarm occurred and
saving parameters.
Check the cooling fan and
the connection of the power
cable for the cooling fan.
If the alarm persists,
replace the cooling fan.
Allow time for cooling before
operation.
Replace the motor or serial
sensor.
Overload.
Spindle amplifier (SP) failure.
Failure of power cable or spindle
motor.
Failure of ladder sequence.
Failure of combination between the
spindle and the spindle motor
(looseness, rupture)
Mismatch of setting switch and
setting parameter.
Disconnect of input cable.
Lags more than 10 seconds of the
timing.
Abnormality in spindle amplifier
(SP).
Failure of external equipment.
Excess in the bottom or reference
point return.
Abnormality is detected in the
cooling fan of the spindle motor.
HPM thyristor exceeded the
reference temperature.
Spindle sensor detected a phase
alarm.
B-64805EN/03
Alarm list
SP
Displ
ay*1
Faulty location / corrective
action
Contents
J7
Replace the CNC printed circuit
board or spindle amplifier control
printed circuit board.
Spindle control software detected
an FSSB communication data error
between DCS and spindle amplifier.
J8
Replace the CNC printed circuit
board or spindle amplifier control
printed circuit board.
Spindle control software detected
an error in communication between
spindle control software and
DCS_S1.
J9
Replace the CNC printed circuit
board or spindle amplifier control
printed circuit board.
Spindle control software detected
an error in communication between
spindle control software and
DCS_S2.
Check the wiring of power
supply (PS) CX48.
Mis-wiring of power supply CX48
(power supply alarm indication of
"11").
Check the breaker, MCC, or
other equipment or cables
installed in the PS input section.
Input power is not supplied to the
power supply (PS) (power supply
alarm indication of "12").
Check the cutting conditions.
An overload is detected in the
power supply (PS) (power supply
alarm indication of "15").
Power supply (PS) failure (power
supply alarm indication of "17").
Number
Message
SP9197
FSSB
COMMUNICATION
ERROR FROM DCS
TO SP
FSSB
COMMUNICATION
ERROR FROM DCS
TO SP
SAFETY
COMMUNICATION
ERROR FROM
DCS_S1 TO SP
SAFETY
COMMUNICATION
ERROR FROM
DCS_S1 TO SP
SAFETY
COMMUNICATION
ERROR FROM
DCS_S2 TO SP
SAFETY
COMMUNICATION
ERROR FROM
DCS_S2 TO SP
PS AC INPUT WRONG
WIRING
PS AC INPUT WRONG
WIRING
PS INPUT POWER
OFF
PS INPUT POWER
OFF
PS SOFT THERMAL
PS SOFT THERMAL
PS PRE-CHARGE
CIRCUIT FAILURE1
PS PRE-CHARGE
CIRCUIT FAILURE1
PS PRE-CHARGE
CIRCUIT FAILURE2
PS PRE-CHARGE
CIRCUIT FAILURE2
PS PRE-CHARGE
CIRCUIT FAILURE3
PS PRE-CHARGE
CIRCUIT FAILURE3
-
Replace the power supply (PS).
-
Replace the power supply (PS).
Power supply (PS) failure (power
supply alarm indication of "18").
-
Check for ground faults in
Ground fault or power supply (PS)
failure (power supply alarm
indication of "19").
SP9198
SP9199
SP9201
SP9202
SP9204
SP9205
SP9206
SP9207
SP9211
SP9212
SP9213
PS ILLEGAL
PARAMETER
PS ILLEGAL
PARAMETER
PS HARDWARE
ERROR
PS HARDWARE
ERROR
PS EXTCOMP.ERROR
-
-
-
motor power cables,
motors, amplifiers, etc.
If the alarm persists,
replace the power supply
(PS).
Change the parameter to an
appropriate value.
Replace the power supply (PS).
Hardware abnormality is detected in
the power supply (PS) (power
supply alarm indication of "24").
Check and replace the
Failure of external input device (AC
reactor, input filter, or power
-
-
An invalid value is set in the power
supply (PS) control parameter
(power supply alarm indication of
"23").
cable.
477
Alarm list
Number
B-64805EN/03
SP
Displ
ay*1
Message
Replace the external input
PS EXTCOMP.ERROR
PS PFB-R ERROR
PS PFB-R ERROR
SP9214
-
PS PFB-C ERROR
PS PFB-C ERROR
SP9215
SP9216
SP9223
-
PS SUB MODULE
ERROR
PS SUB MODULE
ERROR
CLOCK FAILURE
CLOCK FAILURE
Faulty location / corrective
action
-
M3
device.
Replace the power supply
(PS).
Check and replace the
cable.
Replace PFB-R.
Check the regenerative
energy.
Check and replace the
cable.
Replace PFB-C.
Check the capacitor
module.
Check the connection order
and number of power
supply (PS) submodules.
Check the specifications of
the power supply (PS)
submodules.
Replace the spindle amplifier
control printed circuit board.
Contents
transformer), power supply (PS), or
cable (power supply alarm
indication of "25").
Failure of PFB-R or cable, poor
connection, or overload (power
supply alarm indication of "26").
Failure of PFB-C or cable, poor
connection, or overload (power
supply alarm indication of "27").
Wrong order or excessive number
of power failure backup modules
(power supply alarm indication of
"28").
Clock oscillator frequency is
abnormal.
*1: Note that the meanings of the spindle amplifier (SP) indications differ depending on which LED (the red or yellow
LED) is on. When the red LED is on, the spindle amplifier (SP) indicates a 2-digit alarm number.
When the yellow LED is on, the SP indicates an error number that designates a sequence problem (for example, a
rotation command is issued before the emergency stop state is released).
See also "IV.2.3. Error code list (spindle)(P.478)".
2.3.
SP
indicatio
n
*1
01
03
04
05
478
Error code list (spindle)
Contents
Faulty location / corrective action
Although neither *ESP (emergency stop signal;
there are two types of signals including the
input signal and Power Supply (PS) contact
signal) nor MRDY (machine ready signal) is
input, SFR (forward rotation signal)/SRV
(reverse rotation signal)/ORCM (orientation
command) is input.
The parameter settings are such that a position
sensor is not used (position control not
performed) (bits 3, 2, 1, and 0 of parameter No.
4002 are all set to 0), but a Cs contouring
control command is input.
In this case, the motor is not excited.
The parameter settings are such that a position
sensor is not used (position control not
performed) (bits 3, 2, 1, and 0 of parameter
No.4002 are all set to 0), but a servo mode
(rigid tapping, spindle positioning, etc.) or
spindle synchronous control command is input.
In this case, the motor is not excited.
The optional function parameter for the
orientation function is not set, but ORCM
(orientation command) is input.
Check the *ESP and MRDY sequence.
For MRDY, pay attention to the parameter setting
regarding the use of the MRDY signal (bit 0 of parameter
No. 4001).
Check the parameter settings.
Check the parameter settings.
Check the orientation function parameter settings.
B-64805EN/03
SP
indicatio
n
*1
06
07
08
09
10
11
12
13
14
16
17
18
19
21
22
23
Alarm list
Contents
Faulty location / corrective action
The optional function parameter for the speed
range switching control function is not set, but
low-speed characteristic winding is selected
(RCH = 1).
A Cs contouring control command is input, but
SFR (forward rotation command)/SRV (reverse
rotation command) is not input.
A servo mode (rigid tapping, spindle
positioning, etc.) control command is input, but
SFR (forward rotation command)/SRV (reverse
rotation command) is not input.
A spindle synchronous control command is
input, but SFR (forward rotation
command)/SRV (reverse rotation command) is
not input.
A Cs contouring control command is input, but
another mode (servo mode, spindle
synchronous control, or orientation) is
specified.
Check the speed range switching control function
parameter settings and the power line state check signal
(RCH).
A servo mode (rigid tapping, spindle
positioning, etc.) command is input, but
another mode (Cs contouring control, spindle
synchronous control, or orientation) is
specified.
A spindle synchronous control command is
input, but another mode (Cs contouring control,
servo mode or orientation) is specified.
An orientation command is input, but another
mode (Cs contouring control, servo mode, or
spindle synchronous control) is specified.
Both SFR (forward rotation command) and
SRV (reverse rotation command) are input at
the same time.
The parameter settings are such that the
differential speed control function is not used
(bit 5 of parameter No. 4000 = 0), but DEFMD
(differential speed mode command) is input.
The speed detector parameter settings (bits 2,
1, and 0 of parameter No. 4011) are not valid.
There is no corresponding speed detector.
The parameter settings are such that a position
sensor is not used (position control not
performed) (bits 3, 2, 1, and 0 of parameter No.
4002 are all set to 0), but position coder
system orientation is commanded.
The magnetic sensor orientation command is
input, but another mode (Cs contouring control,
servo mode, or spindle synchronous control) is
specified.
The tandem operation command was input
with spindle synchronous control enabled.
Spindle synchronous control was specified in
the tandem operation enable state.
A tandem operation command is input without
the required option.
Check the sequence.
Check the sequence.
Check the sequence.
Do not switch to another mode during a Cs contouring
control command.
Before moving to another mode, cancel the Cs
contouring control command.
Do not switch to another mode during a servo mode
command.
Before moving to another mode, cancel the servo mode
command.
Do not switch to another mode during a spindle
synchronous control command.
Before moving to another mode, cancel the spindle
synchronous control command.
Do not switch to another mode during an orientation
command.
Before moving to another mode, cancel the orientation
command.
Issue either of them.
Check the parameter settings and differential speed
mode command.
Check the parameter settings.
Check the parameter settings and the input signal.
Do not switch to another mode during an orientation
command.
Before moving to another mode, cancel the orientation
command.
Input the tandem operation command when spindle
synchronous control is canceled.
Specify spindle synchronous control when torque
tandem operation is canceled.
Torque tandem control requires an optional function of
CNC software. Check the optional function.
479
Alarm list
SP
indicatio
n
*1
24
26
29
B-64805EN/03
Contents
Faulty location / corrective action
While indexing is performed continuously in
position coder method orientation, an
incremental operation is performed first
(INCMD = 1), and then an absolute position
command (INCMD = 0) is input.
The parameter settings are such that both
spindle switch and three-stage speed range
switch are used.
The parameter settings are such that the
shortest-time orientation function is used (bit 6
of parameter No. 4018 = 0, Nos. 4320 to 4323
≠0).
The magnetic pole has not been detected, but
a command is input.
Check INCMD (incremental command).
If an absolute position command is to follow, be sure to
perform absolute position command orientation first.
30
31
32
33
34
35
The hardware configuration is such that the
spindle FAD function cannot be used.
In this case, the motor is not activated.
S0 is not specified in the velocity mode, but the
disturbance input function is enabled (bit 7 of
parameter No. 4395 is set to 1).
The hardware configuration is such that the
spindle EGB function cannot be used.
In this case, the motor is not activated.
Both the spindle FAD function and the spindle
EGB function are enabled.
In this case, the motor is not activated.
Spindle Amplifier (SP) ID information cannot be
obtained.
The submodule SM (SSM) is faulty.
36
37
38
39
43
44
45
480
The current loop setting (No. 4012) has been
changed.
A parameter related to communication
between spindle amplifiers is specified
incorrectly. Alternatively, a function unavailable
with the torque tandem function is set.
Although SFR (forward rotation command),
SRV (reverse rotation command), or ORCM
(orientation command) is input, DSCN
(disconnection detection disable signal) is
input.
A setting which does not support the αi CZ
sensor (serial) is used.
The spindle amplifier does not support the
control period setting.
The setting does not correspond to the
maximum output control setting cutting.
Check the parameter settings and the input signal.
In the αi series spindle amplifiers, the shortest-time
orientation function cannot be used. The use of the
optimum orientation function is recommended.
In the magnetic pole undetected state (EPFIXA = 0), the
motor cannot be driven even when a command is input.
Input a command in the magnetic pole detected state
(EPFIXA = 1). When EPFSTR is set to 1, any command
is ignored and this error is displayed even in the
magnetic pole detected state. After the completion of
magnetic pole detection, set EPFSTR to 0.
Check the CNC model. With the FS30i series, the
spindle FAD function is not used.
Specify S0 in the velocity mode before enabling the
disturbance input function (bit 7 of parameter No. 4395 to
1).
Check the CNC model.
The two functions cannot be used at the same time.
Enable either function only.
Replace the spindle amplifier (SP) with one with correct
ID information.
For the remedy, refer to the FANUC AC SPINDLE
MOTOR αi/βi series BUILT-IN SPINDLE MOTOR Bi
series PARAMETER MANUAL (B-65280EN).
Check the setting of parameter No. 4012, and turn the
power off, then on again.
Check the parameters.
Check the sequence. Do not input DSCN (disconnection
detection disable signal) during the input of a command
which excites the motor.
Check the parameter settings.
Check the setting of parameter No. 4012.
This is a state error related to the function that performs
output control for cutting. The function cannot be used
for the system in which this state error occurs. Set bit 6
of parameter No.4011 to 0, and disable the function.
B-64805EN/03
SP
indicatio
n
*1
46
48
Alarm list
Contents
Faulty location / corrective action
CNC system software does not support spindle
synchronous control using the nano directive.
CNC system software does not support the nano
directive. Check the series and edition of CNC system
software.
Do not use the spindle EGB when the integral copy via
NC is enabled.
This cannot be used with the following functions.
Conventional control (No.4012#7) =0
Synchronous motor drive (No.4012#6) =1
Spindle interchange (No.4014#0) =1
Low-speed winding selection
Position coder signal output function
After changing the sine wave filter function bit (bit 6 of
parameter No. 4540), and power off the CNC, then on
again.
Check bit 1 of parameter No. 4002 and parameters Nos.
4136, 4137, 4138 and 4139.
In the setting unit IS-D (bits 1 and 0 of parameter No.
4005 are set to 1, 0), the following functions cannot be
used.
Spindle orientation
Servo mode control such as rigid tapping
Spindle synchronous control
Repetition control
Spindle tandem control
Synchronous spindle motor control or non-spindle
HRV control (bits 7 and 6 of parameter No. 4012 ≠
0)
Inter-spindle amplifier communication (bits 7 and 6
of parameter No. 4352 ≠ 0)
Spindle backlash acceleration (bit 0 of parameter
No. 4402 = 1)
Cs contouring control by customer's board
Either disable FSSB high-speed rigid tapping (bit 1 of
parameter No. 4549 = 0) or disable the servo EGB
(FSSB method) (bit 2 of parameter No. 4549 = 0).
The maximum current determined by the current
limitation value exceeds the maximum current for the
amplifier. Check the settings of parameters No. 4619 and
4620.
The base speed for the synchronous spindle motor is
exceeded. Check the use conditions.
Set a value other than 0 in the parameter No. 4074 for
the reference position return speed on servo mode.
A setting is made to use both the integral copy
via NC and the spindle EGB.
The sine wave filter relationship is not set
correctly.
49
Sine wave filter function error.
50
51
The position coder parameters for the βiIc
spindle motor are not set correctly.
Setting unit IS-D: incorrectly set function
52
54
55
56
57
58
FSSB high-speed rigid tapping and the servo
EGB (FSSB method) cannot be used at the
same time.
The current limitation value setting for the
PWM cycle switching function is incorrect.
The speed is too high when the PWM cycle
switching function is used.
The parameter is not set correctly when
optimum orientation and reference position
return on servo mode are used.
The parameter settings unavailable with safety
speed monitoring by the spindle speed are
made.
The setting is incorrect when the least input
increment of 360/32768° is used for the spindle
orientation stop position.
59
60
The sequence in which spindle phase
synchronous control is used is incorrect.
Check the settings of bits 3 to 0 of parameter No. 4002.
CNC system software does not support the least
input increment of 360/32768° for the spindle
orientation stop position. Check the series and
edition of CNC system software.
This cannot be used together with the orientation
function during spindle synchronous control (bit 6 of
parameter No. 4014 = 1).
Check the sequence related to phase alignment for
phase matching in spindle synchronous control. When
the setting is made not to automatically detect the onerotation signal (bit 3 of parameter No. 4006 = 1), this
481
Alarm list
SP
indicatio
n
*1
B-64805EN/03
Contents
63
The DC-link stabilizer at a power failure is not
supported.
64
The sequence is incorrect in the servo EGB
(FSSB method).
Faulty location / corrective action
error occurs if the spindle phase synchronization
command is entered with the one-rotation signal not
detected.
Spindle control software does not support the DC-link
stabilizer at a power failure. Check the series and edition
of spindle control software.
In the setting where both the serve EGB (FSSB method)
and the arbitrary gear ratio function are used, do not
perform gear switching for the serve EGB.
*1: Note that the meanings of the Spindle Amplifier (SP) indications differ depending on which LED, the red or yellow
LED, is on. When the yellow LED is on, an error code is indicated with a 2-digit number. An error code is indicated in
the diagnosis data No. 0710.
When the red LED is on, the Spindle Amplifier (SP) indicates the number of an alarm generated in the serial spindle.
See also "IV.2.2. Alarm List (Spindle)(P.465)".
2.4.
System alarm
The following table lists the alarm messages that may be displayed on the system alarm screen.
Number
Message
Contents
Action
SYS_ALM1
DATA ACCESS EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM2
INSTRUCTION ACCESS EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM3
ALIGNMENT EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM4
PROGRAM EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM5
FLOATING-POINT UNAVAILABLE
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM7
SYSTEM CALL EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
482
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM9
INSTRUCTION TRANSLATION MISS
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM10
DATA LOAD TRANSLATION MISS
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM14
FPU-INVALID OPERATION EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM15
FPU-ZERO DIVIDE EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM16
FPU-OVERFLOW EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM17
FPU-INEXACT EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM18
UNASSIGNED EXCEPTION
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM29
I-CACHE TAG OR DATA ARRAY PARITH ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM30
D-CACHE DATA OR TAG PARITY ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM31
TLB0 ARRAY PARITY ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
SYS_ALM32
483
Alarm list
B-64805EN/03
Message
Contents
Action
L2 MMU MULTI-WAY HIT
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM33
NON MASKABLE INTERRUPT
An abnormality was detected on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM34
LRAT TRANSRATION INTERRUPT
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35
CPU CORE ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36
L2 TAG MULTI-BIT ECC ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM37
L2 DATA MULTI-BIT ECC ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38
L2 cache error
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM39
DDR ADDRESS PARITY ERROR
An error was detected in the memory communication on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM40
DDR CALIBRATION ERROR
An error was detected in the memory communication on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM41
DDR CORRUPTED DATA ERROR
An error was detected in the memory communication on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
SYS_ALM42
DDR ECC MULTI-BIT ERROR
484
B-64805EN/03
Alarm list
Contents
Action
An error was detected in the memory communication on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM43
DDR ERROR
An error was detected in the memory communication on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM44
L3 TAG OR STATUS MULTI-BIT ECC ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM45
L3 DATA MULTI-BIT ECC ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM46
L3 CACHE ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM47
CPU INTERNAL RAM MULTI-BIT ECC ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48
CPU ON-CHIP INTERCONNECT ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49
CPU INTERNAL ERROR
An abnormality was detected inside the CPU on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM50
CPU PCIE3 ERROR
An abnormality was detected in the communication between the CPU board and the main
board.
Replace the CPU board. If it does not recover after replacement, replace the main board. In
addition, please obtain the system alarm log and contact FANUC.
Action
Number
Message
Contents
Action
SYS_ALM51
CPU PCIE4 ERROR
An abnormality was detected in the communication between the CPU board and the main
board.
Replace the CPU board. If it does not recover after replacement, replace the main board. In
addition, please obtain the system alarm log and contact FANUC.
485
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM53
CPU INTERFACE ERROR
An abnormality was detected on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54
SOC OTHER ERROR
An abnormality was detected on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM55
DOUBLE FAULT
An abnormality was detected on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM56
NON MASKABLE INTERRUPT
An abnormality was detected on the CPU board.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM109
ZERO DIVIDE ERROR(INTEGER)
A zero division has occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM110
STACK OVERFLOW(TASK)
A stack overflow occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM111
STACK UNDERFLOW(TASK)
A stack underflow occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM112
STACK OVERFLOW(IRT)
A stack overflow occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM113
STACK UNDERFLOW(IRT)
A stack underflow occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM188
SYSTEM SOFTWARE MISMATCH (TYPE)
The CNC software combination (type) is incorrect.
Please contact FANUC after obtaining the system alarm log.
Number
SYS_ALM189
486
B-64805EN/03
Alarm list
Message
Contents
Action
SYSTEM SOFTWARE MISMATCH (MODEL)
The combination of CPU card and CNC BOOT software or CNC software is incorrect.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM190
SYSTEM SOFTWARE MISMATCH (SERIES)
The combination of the CNC software series is incorrect.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM191
SYSTEM SOFTWARE MISMATCH (EDITION)
The combination of the CNC software edition is incorrect.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM198
SOFTWARE SYSTEM ERROR
An internal error has occurred in the CNC software.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM199
NON MASK INTERRUPT
A hardware exception (NON MASK INTERRUPT) occurred.
Replace the CPU BOARD. In addition, please contact FANUC after obtaining the system alarm
log.
Number
Message
Contents
Action
SYS_ALM600
STACK OVERFLOW(DCS1)
A stack overflow occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM601
STACK UNDERFLOW(DCS1)
A stack underflow occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM602
TIMEOUT(DCS1)
Software processing was not completed in time.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM10100
DDR ECC UNCOLLECTABLE ERROR
A memory communication error has occurred.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM10200
DDR DFI PARITY ERROR
A memory communication error has occurred.
Replace the main board.
Number
Message
SYS_ALM11000
LSI INTERNAL RAM ERROR
487
Alarm list
B-64805EN/03
Contents
Action
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM11900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
SYS_ALM12000
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
488
B-64805EN/03
Alarm list
Action
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM12800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM13200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM13400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
489
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM14400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM14500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM14600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM14700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM14800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM14900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM15000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM15100
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM15200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM15900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
490
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM16000
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM16900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
SYS_ALM17000
491
Alarm list
B-64805EN/03
Message
Contents
Action
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM17900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
SYS_ALM18000
LSI INTERNAL RAM ERROR
492
B-64805EN/03
Alarm list
Contents
Action
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM18900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
SYS_ALM19000
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
493
Alarm list
B-64805EN/03
Action
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM19900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM22100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM22200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM22300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
494
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM22400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM22500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM22600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM22700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM22800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM22900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24700
ECC UNCOLLECTABLE ERROR : PMC IOSRAM (P1)
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24800
CODE ERROR : UNEXPECTED
An abnormality was detected in the ASIC.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24801
CODE ERROR : PMC PROGRAM
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24802
PARITY CHECK ERROR : PMC PROGRAM BUFFER MEMORY
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
495
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM24803
BUS ERROR : PMC PROGRAM CODE TRANSFER PATH
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24804
PMC REGISTER RESTORATION ERROR : DETECTED AT MOVN INST.
An abnormality was detected in the ASIC.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24900
BUS ERROR : UNEXPECTED (P1)
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24901
BUS ERROR : UNEXPECTED ACCESS IN PMC GLOBAL BUS (P1)
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24902
BUS ERROR : UNEXPECTED ACCESS IN PMC CPU BUS (P1)
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM24903
ITP WATCHDOG ERROR : DETECTED BY PMC (P1)
An abnormality was detected in the ASIC.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM25000
I/O LINK I SLAVE #1 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM25500
TICKCON TIMEOUT
Cycle processing was not completed within the time limit.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM25600
SYNCCON TIMEOUT
Cycle processing was not completed within the time limit.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM25700
TMRCON TIMEOUT
Cycle processing was not completed within the time limit.
Please obtain the system alarm log and contact FANUC.
Number
SYS_ALM25800
496
B-64805EN/03
Alarm list
Message
Contents
Action
ITPCON TIMEOUT
Cycle processing was not completed within the time limit.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM26000
ITP SYNCHRONIZATION UNLOCKED
Synchronization between units has been lost.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM26100
CNC ASIC BOOT RAM ECC ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM26200
CNC CPU BOOT BUS ERROR
An error was detected in data transfer between the CPU and ASIC.
Replace the CPU board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM26300
CNC ASIC ON-CHIP BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM26400
SYSTEM EMERGENCY
An abnormality was detected.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM27500
PERIPHERAL ACCESS ERROR
Abnormal access was detected in the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM27600
MEMORY DATA ERROR
A data error was detected in the RAM on the memory board.
Replace the memory board. If it does not recover after replacement, replace the main board.
Number
Message
Contents
Action
SYS_ALM27700
I/O LINK I : RAM ECC/PARITY ALARM(HOST)
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM27800
I/O LINK I : TIMEOUT ALARM
An error was detected in I/O Link i communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
SYS_ALM27900
I/O LINK I : RAM ECC/PARITY ALARM(GROUP)
497
Alarm list
B-64805EN/03
Contents
Action
An error was detected in the memory on the I/O unit.
Replace the relevant I/O unit. In addition, please obtain the system alarm log and contact
FANUC.
Number
Message
Contents
Action
SYS_ALM28000
I/O LINK I : WATCHDOG TIMER ALARM
An error was detected in I/O Link i communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM28100
I/O LINK I : GROUP EXTERNAL ALARM
An error was detected in the I/O unit.
Replace the relevant I/O unit.
Number
Message
Contents
Action
SYS_ALM28200
I/O LINK I : MULTIPLE LSI UNIT ALARM
An error was detected in the I/O unit.
Replace the relevant I/O unit. In addition, please obtain the system alarm log and contact
FANUC.
Number
Message
Contents
SYS_ALM28300
I/O LINK I : DISTRIBUTED LINK ALARM
A communication failure occurred in the connection of I/O Unit-MODEL B or the connection
between the handy machine operation panel interface unit and the handy machine operation
panel.
Confirm that there are no noise sources nearby and that the relevant I/O unit is properly
grounded. Check to see if there is any disconnection or contact failure between the units. If
there is no problem, replace the relevant I/O unit.
Action
Number
Message
Contents
Action
SYS_ALM28400
I/O LINK I : GROUP POWER FAILURE
An I/O unit power failure was detected.
Check the power supply of the relevant I/O unit. If there is no problem, replace the relevant I/O
unit.
Number
Message
Contents
Action
SYS_ALM28500
I/O LINK I : DISCONNECTION
A disconnection was detected in I/O Link i communication.
Check to see if there is any disconnection or contact failure at the location displayed on the
screen. If there is no problem, replace the relevant I/O unit.
Number
Message
Contents
Action
SYS_ALM28600
I/O LINK I MASTER CH.4 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM28800
I/O LINK I : GROUP DCS ALARM
An error was detected in the control function of the I/O Link i communication main board or
CPU board.
Replace the main board or CPU board. In addition, please obtain the system alarm log and
contact FANUC.
Action
Number
498
SYS_ALM28900
B-64805EN/03
Alarm list
Message
Contents
Action
I/O LINK I : DATA TRANSMISSION FAILURE
An error was detected in I/O Link i communication.
Confirm that there are no noise sources nearby and that the relevant I/O unit is properly
grounded at the location displayed on the screen. In addition, check to see if there is a contact
failure in the relevant cable.
Number
Message
Contents
Action
SYS_ALM29000
I/O LINK I : UNIDEFINED FAILURE
An error was detected in I/O Link i communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM29700
I/O LINK I MASTER CH.2 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM29900
MODULE LINK I : ANALYSIS FAILURE
An error was detected in Slice I/O.
Replace the Slice I/O interface module housing. In addition, please obtain the system alarm log
and contact FANUC.
Number
Message
Contents
Action
SYS_ALM30000
MODULE LINK I : RAM ECCALARM (SLOT)
A memory error was detected in the Slice I/O slot.
Replace the housing of the relevant slot of Slice I/O.
Number
Message
Contents
Action
SYS_ALM30100
MODULE LINK I : I/O CONTROL FAILURE
An error was detected in the Slice I/O slot.
Replace the housing of the relevant slot of Slice I/O.
Number
Message
Contents
Action
SYS_ALM30200
MODULE LINK I : SLOT EXTERNAL ALARM
A temperature abnormality was detected in the Slice I/O slot.
Replace the housing of the relevant slot of Slice I/O.
Number
Message
Contents
Action
SYS_ALM30300
MODULE LINK I : SLOT POWER FAILURE
A power failure was detected in the Slice I/O slot.
Replace the housing of the relevant slot of Slice I/O.
Number
Message
Contents
Action
SYS_ALM30400
MODULE LINK I : DISCONNECTION
A disconnection was detected in communication between Slice I/O modules.
Check to see if there is a contact failure at the location displayed on the screen.
Number
Message
Contents
Action
SYS_ALM30500
MODULE LINK I : TIMEOUT ALARM
A communication error was detected between Slice I/O modules.
Replace the Slice I/O interface module housing. In addition, please obtain the system alarm log
and contact FANUC.
499
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM30600
MODULE LINK I : DCS ALARM
A communication error was detected between Slice I/O modules.
Replace the affected Slice I/O interface module or slot housing. In addition, please obtain the
system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM30700
MODULE LINK I : WATCHDOG TIMER ALARM
A communication error was detected between Slice I/O modules.
Replace the affected Slice I/O interface module or slot housing. In addition, please obtain the
system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM30800
I/O LINK I MASTER CH.3 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM31000
MODULE LINK I : DATA TRANSMISSION FAILURE
A communication error was detected between Slice I/O modules.
Confirm that there are no noise sources nearby and that the relevant I/O unit is properly
grounded and that there is no contact failure at the location displayed on the screen.
Number
Message
Contents
Action
SYS_ALM31100
MODULE LINK I : UNDEFINED FAILURE
A communication error was detected between Slice I/O modules.
Replace the Slice I/O interface module housing. In addition, please obtain the system alarm log
and contact FANUC.
Number
Message
Contents
Action
SYS_ALM31900
I/O LINK I MASTER CH.1 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
SYS_ALM32500
DMA DATA TRANSFER ERROR
500
B-64805EN/03
Alarm list
Contents
Action
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM32900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM33000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM33100
PCIE GENERAL ERROR
An error was detected in the data transfer between the main board and the CPU board.
Replace the main board or CPU board. In addition, please obtain the system alarm log and
contact FANUC.
Number
Message
Contents
Action
SYS_ALM33300
PCIE GENERAL ERROR/SLOT1: 2 SLOT TYPE/SLOT4: 4 SLOT TYPE
An error was detected in the data transfer between the main board and the optional board.
Replace the main board or the optional board in slot 1. In addition, please obtain the system
alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM33400
PCIE GENERAL ERROR (SLOT2)
An error was detected in the data transfer between the main board and the optional board.
Replace the main board or the optional board in slot 2. In addition, please obtain the system
alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM33500
PCIE GENERAL ERROR (SLOT3)
An error was detected in the data transfer between the main board and the optional board.
Replace the main board or the optional board in slot 3. In addition, please obtain the system
alarm log and contact FANUC.
501
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM35200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM35900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36100
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
SYS_ALM36200
502
B-64805EN/03
Alarm list
Message
Contents
Action
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM36700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM37500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM37800
SPI TRANSFER ERROR
An error occurred in intra-board communication.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM37900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
SYS_ALM38100
DMA DATA TRANSFER ERROR
503
Alarm list
B-64805EN/03
Contents
Action
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM38700
INTERNAL FLASH TRANSFER ERROR
An error occurred in the main storage communication.
Replace the memory board.
Number
Message
Contents
Action
SYS_ALM39200
INTERNAL FLASH AXI WRITE ERROR
An error occurred in the main storage communication.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM39300
SD TRANSFER ERROR
An error occurred in the SD card communication.
Replace the SD card inserted into the memory board.
Number
Message
Contents
Action
SYS_ALM39800
SD AXI WRITE ERROR
An error occurred in the SD card communication.
Replace the main board.
Number
Message
Contents
SYS_ALM40000
USB HOST SYSTEM ERROR
An error occurred in USB communication.
504
B-64805EN/03
Alarm list
Action
Replace the main board.
Number
Message
Contents
Action
SYS_ALM40100
UART TIMEOUT
An error occurred in serial communication.
Check the serial port for broken wires or poor contact.
Number
Message
Contents
Action
SYS_ALM40200
UART TIMEOUT
An error occurred in serial communication.
Check the serial port for broken wires or poor contact.
Number
Message
Contents
Action
SYS_ALM40300
I2C BUS ERROR
An error occurred in intra-board communication.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM40400
I2C BUS ERROR
An error occurred in intra-board communication.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM40500
I2C BUS ERROR
An error occurred in intra-board communication.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM43000
DSP CORE VOLTAGE ERROR
A power supply error has occurred on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM43100
LSI CORE VOLTAGE ERROR
A power supply error has occurred on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM43900
EXPANSION SLOT ERROR
A hardware defect has occurred on the expansion board.
Replace the expansion board.
Number
Message
Contents
Action
SYS_ALM44400
200V POWER OFF
A power supply error has occurred.
Check that the 24V power supply connector and pin assignments are correct. If it does not
recover, replace the power supply board.
Number
Message
Contents
Action
SYS_ALM44600
CPU CORE VOLTAGE ERROR
A power supply error has occurred on the CPU board.
Replace the CPU board.
505
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM44700
CPU ERROR
A hardware defect has occurred on the CPU board.
Replace the CPU board.
Number
Message
Contents
Action
SYS_ALM44800
OPTION ERROR
A hardware defect has occurred on the optional board.
Replace the optional board in the corresponding slot.
Number
Message
Contents
Action
SYS_ALM44900
OPTION ERROR
A hardware defect has occurred on the optional board.
Replace the optional board in the corresponding slot.
Number
Message
Contents
Action
SYS_ALM45000
OPTION ERROR
A hardware defect has occurred on the optional board.
Replace the optional board in the corresponding slot.
Number
Message
Contents
Action
SYS_ALM45100
OPTION ERROR
A hardware defect has occurred on the optional board.
Replace the optional board in the corresponding slot.
Number
Message
Contents
Action
SYS_ALM47200
LSI CORE VOLTAGE ERROR
A power supply error has occurred on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM48600
STO SUPPORT MACRO CH.1 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM48701
FSSB HOST : DISCONNECTION (MAIN <- YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. FSSB communication between the units
indicated in parentheses in the message is not possible.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
Action
Number
Message
Contents
Action
Number
Message
506
SYS_ALM48702
FSSB DEVICE : DISCONNECTION (XXXn -> YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. FSSB communication between the units
indicated in parentheses in the message is not possible.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
SYS_ALM48703
FSSB DEVICE : INTERNAL DISCONNECTION (AMPn ->) /LINEx
B-64805EN/03
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Alarm list
An alarm was detected at LINEx of the FSSB. A communication data error was detected inside
the amplifier indicated in parentheses in the message.
Replace the corresponding amplifier.
SYS_ALM48704
FSSB DEVICE : DISCONNECTION (XXXn <- YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. FSSB communication between the units
indicated in parentheses in the message is not possible.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
SYS_ALM48705
FSSB DEVICE : INTERNAL DISCONNECTION (AMPn <-) /LINEx
An alarm was detected at LINEx of the FSSB. A communication data error was detected inside
the amplifier indicated in parentheses in the message.
Replace the corresponding amplifier.
SYS_ALM48706
FSSB HOST : ECC ERROR (XXXn <- YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
SYS_ALM48707
FSSB HOST : SP. DATA ECC ERROR (XXXn <- YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
Number
Message
Contents
Action
SYS_ALM48708
FSSB HOST : ECC ERROR /LINEx
An alarm was detected at LINEx of the FSSB. A communication data error occurred.
Please obtain the system alarm log and contact FANUC. In addition, replace the main board.
Number
Message
Contents
Action
SYS_ALM48709
FSSB HOST : SPINDLE DATA ECC ERROR /LINEx
An alarm was detected at LINEx of the FSSB. A communication data error occurred.
Please obtain the system alarm log and contact FANUC. In addition, replace the main board.
Number
Message
Contents
SYS_ALM48710
FSSB DEVICE : ECC ERROR (XXXn -> YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
Action
Number
Message
Contents
Action
SYS_ALM48711
FSSB DEVICE : SP. DATA ECC ERROR (XXXn -> YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
507
Alarm list
Number
Message
Contents
Action
B-64805EN/03
SYS_ALM48712
FSSB DEVICE : SDU DATA ECC ERROR (XXXn -> YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections.
Number
Message
Contents
Action
SYS_ALM48713
FSSB DEVICE : ECC ERROR /LINEx
An alarm was detected at LINEx of the FSSB. A communication data error occurred.
Please obtain the system alarm log and contact FANUC. In addition, replace the main board.
Number
Message
Contents
Action
SYS_ALM48714
FSSB DEVICE : SPINDLE DATA ECC ERROR /LINEx
An alarm was detected at LINEx of the FSSB. A communication data error occurred.
Please obtain the system alarm log and contact FANUC. In addition, replace one of the spindle
amplifiers.
Number
Message
Contents
Action
SYS_ALM48715
FSSB DEVICE : SDU DATA ECC ERROR /LINEx
An alarm was detected at LINEx of the FSSB. A communication data error occurred.
Please obtain the system alarm log and contact FANUC. In addition, replace one of the
separate detector interface units.
Number
Message
Contents
Action
SYS_ALM48730
FSSB HOST : UNDEFINED ERR CODE WW
An alarm was detected in the FSSB.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48731
FSSB HOST : UNDEFINED ERR
An alarm was detected in the FSSB.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM48732
FSSB HOST : ILLEGAL ERROR CODE (XXXn <- YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections. If the error still occurs, obtain the system alarm log and contact FANUC.
Action
Number
Message
Contents
Action
SYS_ALM48733
FSSB HOST : RECEIVE ILLEGAL ERROR CODE /LINEx
An alarm was detected at LINEx of the FSSB.
Please obtain the system alarm log and contact FANUC. In addition, replace one of the FSSB
units.
Number
Message
Contents
SYS_ALM48734
FSSB DEVICE : UNDEFINED ERROR CODE VV (XXXn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit. If the error still occurs, obtain the system alarm log and contact
FANUC.
Action
508
B-64805EN/03
Number
Message
Contents
Action
Alarm list
SYS_ALM48735
FSSB DEVICE : ILLEGAL ERROR CODE (XXXn -> YYYm) /LINEx
An alarm was detected at LINEx of the FSSB. An error occurred in the communication data
between the units indicated in parentheses in the message.
Replace either the corresponding main board, the unit, or the optical cable between the
relevant connections. If the error still occurs, obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48736
FSSB DEVICE : RECEIVE ILLEGAL ERROR CODE /LINEx
An alarm was detected at LINEx of the FSSB.
Please obtain the system alarm log and contact FANUC. In addition, replace one of the FSSB
units.
Number
Message
Contents
Action
SYS_ALM48740
FSSB HOST : BUS PARITY ERROR
An abnormality was detected in the ASIC.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM48741
FSSB HOST : SPINDLE RAM PARITY ERROR
An abnormality was detected in the ASIC.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM48742
AXIS CONTROL : RAM ECC ERROR
An abnormality was detected in the ASIC.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM48743
AXIS CONTROL : DMA UNFINISHED : DSP
An error was detected in the servo control.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48744
AXIS CONTROL : DMA UNFINISHED : ASIC
An error was detected in the CNC processing or data.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48745
AXIS CONTROL : ACCESS ERROR : WRITE PROTECT
An error was detected in the CNC processing.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48746
AXIS CONTROL : ACCESS ERROR : ABNORMAL RESPONSE
An error was detected in the CNC processing.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM48747
AXIS CONTROL : ACCESS ERROR : ILLEGAL TIMING
An error was detected in the CNC processing.
509
Alarm list
B-64805EN/03
Action
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48748
AXIS CONTROL : ACCESS ERROR : TIMEOUT
An error was detected in the CNC processing.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48749
AXIS CONTROL : ACCESS ERROR : ILLEGAL FORMAT
An error was detected in the CNC processing.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48750
AXIS CONTROL : ACCESS ERROR : ILLEGAL ADDRESS
An error was detected in the CNC processing.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM48751
FSSB DEVICE : SPINDLE SOFT ACCESS ERROR (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit. In addition, please obtain the system alarm log and contact FANUC.
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
SYS_ALM48752
FSSB DEVICE : SPINDLE RAM PARITY ERROR (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48753
FSSB DEVICE : BUS PARITY ERROR (XXXn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48754
FSSB DEVICE : AMP LSI BUS PARITY ERROR (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
Action
SYS_ALM48755
FSSB DEVICE : SDU LSI BUS PARITY ERROR (SDUn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
Number
Message
Contents
Action
SYS_ALM48770
FSSB HOST : ITP SYNC ERROR
An error was detected in the servo control.
Please obtain the system alarm log and contact FANUC. In addition, replace the main board.
510
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM48771
AXIS CONTROL : ITP WATCH DOG
An error was detected in the servo control.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM48772
AXIS CONTROL : SERVO WATCH DOG ALARM
An error was detected in the servo control.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM48773
AXIS CONTROL : DSP DETECT ERROR
An error was detected in the servo control.
Please obtain the system alarm log and contact FANUC. In addition, replace the main board.
Number
Message
Contents
SYS_ALM48774
FSSB DEVICE : ABNORMAL POWER SUPPLY (XXXn) /LINEx
An alarm was detected at LINEx of the FSSB. An power supply error was detected in the unit
indicated in parentheses in the message.
A drop in the power supply voltage input to the affected unit has been detected. Check for
abnormalities in the power supply or power cable, and check for voltage drops in the input
power supply.
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
SYS_ALM48775
AMP LOCAL ERROR NO.0 (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An power supply error was detected in the unit
indicated in parentheses in the message.
Check for shorts in the encoder cable connected to the unit. If there is no problem, replace the
relevant unit.
SYS_ALM48776
SDU LOCAL ERROR NO.0 (SDUn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48777
AMP LOCAL ERROR NO.1 (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48778
AMP LOCAL ERROR NO.2 (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48779
FSSB DEVICE : SERVO AMP SOFT WATCH DOG (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
511
Alarm list
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
B-64805EN/03
SYS_ALM48780
SDU LOCAL ERROR NO.2 (SDUn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48781
AMP LOCAL ERROR NO.3 (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit.
SYS_ALM48782
FSSB DEVICE : ABNORMAL POWER SUPPLY 5V (SDUn) /LINEx
An alarm was detected at LINEx of the FSSB. An power supply error was detected in the unit
indicated in parentheses in the message.
Check for shorts in the encoder cable connected to the unit. If there is no problem, replace the
relevant unit.
Action
SYS_ALM48783
FSSB DEVICE : SPINDLE SOFT WATCH DOG (AMPn) /LINEx
An alarm was detected at LINEx of the FSSB. An error was detected in the unit indicated in
parentheses in the message.
Replace the relevant unit. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
SYS_ALM49800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
512
B-64805EN/03
Alarm list
Action
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM49900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50100
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM50800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
513
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM50900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51100
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM51800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM51900
PCIE GENERAL ERROR
An error was detected in the data transfer between the main board and the CPU board.
Replace the main board or CPU board. In addition, please obtain the system alarm log and
contact FANUC.
514
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM52000
PCIE GENERAL ERROR
An error was detected in the data transfer on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM52100
PCIE GENERAL ERROR
An error was detected in the data transfer on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM52200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM52900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
SYS_ALM53000
515
Alarm list
B-64805EN/03
Message
Contents
Action
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM53700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM53800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM53900
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54000
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54100
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM54600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
SYS_ALM54800
LSI INTERNAL RAM ERROR
516
B-64805EN/03
Alarm list
Contents
Action
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM55100
DCS SUPPORT MACRO #2 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM55200
I/O LINK I SLAVE #2 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM55300
STO SUPPORT MACRO CH.2 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM55900
ECC UNCOLLECTABLE ERROR : PMC IOSRAM (P2)
An error was detected in the ASIC memory on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM56100
BUS ERROR : UNEXPECTED (P2)
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM56101
BUS ERROR : UNEXPECTED ACCESS IN PMC GLOBAL BUS (P2)
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM56102
BUS ERROR : UNEXPECTED ACCESS IN PMC CPU BUS (P2)
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM56103
ITP WATCHDOG ERROR : DETECTED BY PMC (P2)
An abnormality was detected in the ASIC.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM56500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
SYS_ALM56700
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
517
Alarm list
B-64805EN/03
Action
Replace the main board.
Number
Message
Contents
Action
SYS_ALM56900
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM57100
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM57300
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM59000
DCS SUPPORT MACRO #1 BUS ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59100
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59200
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59300
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59400
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59500
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59600
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
518
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM59700
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM59800
DMA DATA TRANSFER ERROR
An error was detected in data transfer within the ASIC on the main board.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM60000
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM60200
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM60400
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Description
Action
SYS_ALM60500
CPU EXECPTION (H1)
An error was detected in the CNC software. A CPU exception occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Description
Action
SYS_ALM60501
IDROM DATA IS BROKEN
IDROM data is broken. (CPU board)
The data in the nonvolatile memory on the CPU board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60502
IDROM DATA IS BROKEN
IDROM data is broken. (Memory board)
The data in the nonvolatile memory on the memory board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60503
IDROM DATA IS BROKEN
IDROM data is broken. (Interface board)
The data in the nonvolatile memory on the interface board has been partially corrupted. Please
contact FANUC for replacement.
Number
Message
Description
SYS_ALM60504
IDROM DATA IS BROKEN
IDROM data is broken. (Main board)
519
Alarm list
B-64805EN/03
Action
The data in the nonvolatile memory on the main board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60505
IDROM DATA IS BROKEN
IDROM data is broken. (Power supply board)
The data in the nonvolatile memory on the power supply board has been corrupted. Please
contact FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60506
IDROM DATA IS BROKEN
IDROM data is broken. (Back board)
The data in the nonvolatile memory on the back board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60507
IDROM DATA IS BROKEN
IDROM data is broken. (Expansion board)
The data in the nonvolatile memory on the expansion board is partially corrupted. Please
contact FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60508
IDROM DATA IS BROKEN
IDROM data is broken. (Option board 1)
The data in the nonvolatile memory on the option board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60509
IDROM DATA IS BROKEN
IDROM data is broken. (Option board 2)
The data in the nonvolatile memory on the option board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60510
IDROM DATA IS BROKEN
IDROM data is broken. (Option board 3)
The data in the nonvolatile memory on the option board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
Action
SYS_ALM60511
IDROM DATA IS BROKEN
IDROM data is broken. (Option board 4)
The data in the nonvolatile memory on the option board is partially corrupted. Please contact
FANUC for replacement.
Number
Message
Description
SYS_ALM60521
CNC UNIT OVERHEATED (MAIN BOARD)
The following board in the CNC unit has reached an abnormal temperature.
- Main board
The main board in the CNC unit has reached an abnormally high temperature. Take measures
to reduce the ambient temperature of the area where the CNC unit is installed.
If there is no apparent abnormality in the ambient temperature, the main board may be
defective.
Action
520
B-64805EN/03
Number
Message
Description
Action
Number
Message
Description
Action
Number
Message
Description
Action
Alarm list
SYS_ALM60522
CNC UNIT OVERHEATED (MAIN BOARD)
The following board in the CNC unit has reached an abnormal temperature.
- Main board
The main board in the CNC unit has reached an abnormally high temperature. Take measures
to reduce the ambient temperature of the area where the CNC unit is installed.
If there is no apparent abnormality in the ambient temperature, the main board may be
defective.
SYS_ALM60523
CNC UNIT OVERHEATED (MAIN BOARD)
The following board in the CNC unit has reached an abnormal temperature.
- Main board
The main board in the CNC unit has reached an abnormally high temperature. Take measures
to reduce the ambient temperature of the area where the CNC unit is installed.
If there is no apparent abnormality in the ambient temperature, the main board may be
defective.
SYS_ALM60524
CNC UNIT OVERHEATED (CPU BOARD)
The following board in the CNC unit has reached an abnormal temperature.
- CPU board
The CPU board in the CNC unit has reached an abnormally high temperature. Take measures
to reduce the ambient temperature of the area where the CNC unit is installed.
If there is no apparent abnormality in the ambient temperature, the CPU board may be
defective.
Number
Message
Contents
Action
SYS_ALM60600
FAN STOP
A low RPM of the fan motor of the control unit was detected.
Replace the fan motor of the control unit.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60601
FAN ID
Failed to acquire fan unit configuration information.
Replace the main board.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60602
VOLTAGE ERROR
The DCS2 software detected abnormal voltage values.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60603
FSSB FREQUENCY SETTING CONFIRMATION ERROR
The clock monitoring FSSB clock type is invalid.
Replace the main board.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60604
MAIN ASIC TEMPERATURE SENSOR ERROR
Failed to initialize the main board temperature sensor.
Replace the main board.
521
Alarm list
B-64805EN/03
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60605
CPU BOARD TEMPERATURE SENSOR ERROR
Failed to initialize the CPU board temperature sensor.
Replace the CPU board.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Description
Action
SYS_ALM60606
IDROM INFO ERROR
The data in the nonvolatile memory on the memory board is partially corrupted.
Replace the memory board.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60611
FAN 1 STOP
A low RPM of fan motor 1 of the control unit was detected.
Replace fan motor 1 of the control unit.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60612
FAN 2 STOP
A low RPM of fan motor 2 of the control unit was detected.
Replace fan motor 2 of the control unit.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60620
S1 VERSION ERROR
An error was detected in the DCS software. A mismatch in S1 version was detected.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60621
P1 VERSION ERROR
An error was detected in the DCS software. A mismatch in P1 version was detected.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60630
SYSTEM RESOURCE ERROR (TYPE:FLAG)
An error was detected in the DCS software. Failed to initialize event flag system resources.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60631
SYSTEM RESOURCE ERROR (TYPE:TASK)
An error was detected in the DCS software. Failed to initialize task system resources.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
SYS_ALM60632
SYSTEM RESOURCE ERROR (TYPE:INTERRUPT)
An error was detected in the DCS software. Failed to initialize interrupt handler system
resources.
Please contact FANUC after obtaining the system alarm log.
Action
522
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM60633
MEMORY TEST ERROR (STACK)
An error was detected in the DCS software. A stack area RAM check error occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60634
DEVICE INIT ERROR
An error was detected in the DCS software. Device driver initialization failed.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60635
CPU EXCEPTION
An error was detected in the DCS software. A CPU exception occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60636
SYSTEM RESOURCE ERROR (TYPE:EXCEPTION)
An error was detected in the DCS software. Failed to initialize exception handler system
resources.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60660
DCSPMC2 INTERNAL ERROR
An error was detected in the DCS software. A DCSPMC2 internal error occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60661
DCSPMC2 PROGRAM UPDATE FAIL
An error was detected in the DCS software. Failed to update DCSPMC2 program data.
Please reboot and retry updating the program.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
SYS_ALM60662
DCSPMC2 ILLEGAL PROGRAM SPE
An error was detected in the DCS software. A stack error occurred in the SPE instruction of the
DCSPMC2 program.
Please contact FANUC after obtaining the system alarm log.
Action
Number
Message
Contents
Action
SYS_ALM60663
DCSPMC2 ILLEGAL PROGRAM FBE
An error was detected in the DCS software. A stack error occurred in the FBE instruction of the
DCSPMC2 program.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60664
DCSPMC2 SAFETY I/O ALARM
A safety I/O communication error was detected.
An error in I/O communication for DCSPMC was detected.
Replace the I/O unit for DCSPMC.
If replacing the I/O unit for DCSPMC does not restore the system, replace the main board.
Number
Message
SYS_ALM60665
DCSPMC2 PROGRAM CRC ERROR
523
Alarm list
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
B-64805EN/03
An error was detected in the DCS software. A DCSPMC2 program data RAM check error
occurred.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM60666
DCSPMC2 PROGRAM STACK ERROR
An error was detected in the DCS software. A stack error (OVER) occurred during DCSPMC2
program execution.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM60667
DCSPMC2 PROGRAM STACK ERROR
An error was detected in the DCS software. A stack error (UNDER) occurred during DCSPMC2
program execution.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM60668
DCSPMC2 PROGRAM NEST ERROR
An error was detected in the DCS software. A nesting error detected during DCSPMC2
program execution.
Please contact FANUC after obtaining the system alarm log.
Action
SYS_ALM60669
DCSPMC2 ILLEGAL PROGRAM FCST(STACK)
An error was detected in the DCS software. A stack error occurred in the FCST instruction of
the DCSPMC2 program.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60699
P2 ILLEGAL
An error was detected in the DCS software.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60800
S2 VERSION ERROR
An error was detected in the DCS software. A mismatch in S2 version was detected.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60801
CNC VERSION ERROR
An error was detected in the DCS software. A mismatch in CNC version was detected.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60860
DCSPMC1 INTERNAL ERROR
An error was detected in the DCS software. A DCSPMC1 internal error occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60861
DCSPMC1 PROGRAM UPDATE FAIL
An error was detected in the DCS software. Failed to update DCSPMC1 program data.
Please reboot and retry updating the program.
In addition, please contact FANUC after obtaining the system alarm log.
524
B-64805EN/03
Number
Message
Contents
Action
Number
Message
Contents
Action
Alarm list
SYS_ALM60862
DCSPMC1 ILLEGAL PROGRAM SPE
An error was detected in the DCS software. A stack error occurred in the SPE instruction of the
DCSPMC1 program.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM60863
DCSPMC1 ILLEGAL PROGRAM FBE
An error was detected in the DCS software. A stack error occurred in the FBE instruction of the
DCSPMC1 program.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM60864
DCSPMC1 SAFETY I/O ALARM
A safety I/O communication error was detected.
An error in I/O communication for DCSPMC was detected.
Replace the I/O unit for DCSPMC.
If replacing the I/O unit for DCSPMC does not restore the system, replace the main board.
Number
Message
Contents
SYS_ALM60865
DCSPMC1 PROGRAM CRC ERROR
An error was detected in the DCS software. A DCSPMC1 program data RAM check error
occurred.
Please contact FANUC after obtaining the system alarm log.
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
SYS_ALM60866
DCSPMC1 PROGRAM STACK ERROR
An error was detected in the DCS software. A stack error (OVER) occurred during DCSPMC1
program execution.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM60867
DCSPMC1 PROGRAM STACK ERROR
An error was detected in the DCS software. A stack error (UNDER) occurred during DCSPMC1
program execution.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM60868
DCSPMC1 PROGRAM NEST ERROR
An error was detected in the DCS software. A nesting error detected during DCSPMC1
program execution.
Please contact FANUC after obtaining the system alarm log.
Action
SYS_ALM60869
DCSPMC1 ILLEGAL PROGRAM FCST(STACK)
An error was detected in the DCS software. A stack error occurred in the FCST instruction of
the DCSPMC1 program.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
SYS_ALM60899
S1 ILLEGAL
An error was detected in the DCS software.
525
Alarm list
B-64805EN/03
Action
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61200
DEVICE INIT ERROR (P1)
An error was detected in the CNC software. Device driver initialization failed.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61201
CPU EXCEPTION (P1)
An error was detected in the CNC software. A CPU exception occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61220
PMC INTERNAL ERROR
An error was detected in the PMC software. An internal error occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61221
PMC MESSAGE CRC ERROR
An error was detected in the PMC software. A message data RAM check error occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61222
PMC PROGRAM CRC ERROR
An error was detected in the PMC software. A program data RAM check error occurred.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61223
PMC TRANSFER SYNCHRONIZATION BUFFER
An error was detected in the PMC software. Failed to synchronize I/O signals.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61225
PMC PROGRAM UPDATE FAIL
An error was detected in the PMC software. Failed to update the program.
Please reboot and retry updating the program.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61226
PMC MESSAGE UPDATE FAIL
An error was detected in the PMC software. Failed to update the message data.
Please reboot and retry updating the message.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61227
PMC EXTENDED MESSAGE UPDATE FAIL
An error was detected in the PMC software. Failed to update the message data.
Please reboot and retry updating the message.
In addition, please contact FANUC after obtaining the system alarm log.
Number
Message
SYS_ALM61240
PMC ILLEGAL PROGRAM SPE
526
B-64805EN/03
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Action
Number
Message
Contents
Alarm list
An error was detected in the PMC software. A stack error occurred in the SPE instruction of the
program.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM61241
PMC ILLEGAL PROGRAM FBE
An error was detected in the PMC software. A stack error occurred in the FBE instruction of the
program.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM61242
PMC PROGRAM STACK ERROR (OVER)
An error was detected in the PMC software. A stack error (OVER) occurred during program
execution.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM61243
PMC PROGRAM STACK ERROR (UNDER)
An error was detected in the PMC software. A stack error (UNDER) occurred during program
execution.
Please contact FANUC after obtaining the system alarm log.
SYS_ALM61244
PMC PROGRAM NEST ERROR
An error was detected in the PMC software. A nesting error detected during program
execution.
Please contact FANUC after obtaining the system alarm log.
Action
SYS_ALM61245
PMC ILLEGAL PROGRAM FCST(STACK)
An error was detected in the PMC software. A stack error occurred in the FCST instruction of
the program.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61299
P1 ILLEGAL
An error was detected in the PMC/network software.
Please contact FANUC after obtaining the system alarm log.
Number
Message
Contents
Action
SYS_ALM61500
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM61600
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM61800
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
527
Alarm list
B-64805EN/03
Number
Message
Contents
Action
SYS_ALM62000
LSI INTERNAL RAM ERROR
An error was detected in the ASIC memory on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM62100
ETHERNET H1 DATA TRANSFER ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM63100
ETHERNET H1 WATCH DOG TIMEOUT
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM63300
ETHERNET H1 ECC ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM63400
ETHERNET H2 DATA TRANSFER ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM64400
ETHERNET H2 WATCH DOG TIMEOUT
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM64600
ETHERNET H2 ECC ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM64700
ETHERNET P1 DATA TRANSFER ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM65700
ETHERNET P1 WATCH DOG TIMEOUT
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM65900
ETHERNET P1 ECC ERROR
An error was detected in Ethernet communication.
Replace the Ethernet expansion board. If it does not recover after replacement, replace the
main board. In addition, please obtain the system alarm log and contact FANUC.
528
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM66000
ETHERNET P2 DATA TRANSFER ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM67000
ETHERNET P2 WATCH DOG TIMEOUT
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM67200
ETHERNET P2 ECC ERROR
An error was detected in Ethernet communication.
Replace the Ethernet expansion board. If it does not recover after replacement, replace the
main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM67300
ETHERNET P3 DATA TRANSFER ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM68300
ETHERNET P3 WATCH DOG TIMEOUT
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM68600
ETHERNET P4 DATA TRANSFER ERROR
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM69600
ETHERNET P4 WATCH DOG TIMEOUT
An error was detected in Ethernet communication.
Replace the main board. In addition, please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM70000
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70100
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70200
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
SYS_ALM70300
529
Alarm list
B-64805EN/03
Message
Contents
Action
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70400
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70500
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70600
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70700
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70800
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM70900
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM71000
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71100
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71200
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
530
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM71300
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71400
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71500
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71600
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71700
CLOCK FREQUENCY ERROR(PCIE CLOCK)
An error was detected in the clock on the back board.
Replace the back board or case unit. If it does not recover after replacement, replace the main
board.
Number
Message
Contents
Action
SYS_ALM71800
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM71900
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72000
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72100
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
SYS_ALM72200
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
531
Alarm list
B-64805EN/03
Action
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72300
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72400
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72500
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72600
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72700
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72800
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM72900
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM73000
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM73100
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM73200
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
532
B-64805EN/03
Alarm list
Number
Message
Contents
Action
SYS_ALM73300
CLOCK FREQUENCY ERROR
An error was detected in the clock on the main board.
Replace the main board.
Number
Message
Contents
Action
SYS_ALM73400
TICKCON OUT OF TIME WINDOW
Processing time exceeded the specified range.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM73500
SYNCCON OUT OF TIME WINDOW
Processing time exceeded the specified range.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM73600
TMRCON OUT OF TIME WINDOW
Processing time exceeded the specified range.
Please obtain the system alarm log and contact FANUC.
Number
Message
Contents
Action
SYS_ALM73700
ITPCON OUT OF TIME WINDOW
Processing time exceeded the specified range.
Please obtain the system alarm log and contact FANUC.
533
Diagnosis list
B-64805EN/03
3.
Diagnosis list
3.1.
Diagnosis list
Causes when the machine does not travel in spite of giving a command
DGN 0
CNC internal state 1
[Data type]
Bit path
Internal state when "1" is displayed
NAME
#
INPOSITION CHECK
0
#
FEEDRATE OVERRIDE 0%
1
#
JOG FEED OVERRIDE 0%
2
#
Interlock/start lock
3
#
SPEED ARRIVAL ON
4
#
WAIT REVOLUTION
5
#
STOP POSITION CODER
6
DGN 2
Dwell execution state
[Data type]
Bit path
Internal state when "1" is displayed
In-position check is being done.
Feedrate override is 0%.
Jog feedrate override is 0%.
Interlock/start lock is on.
The system is waiting for the speed arrival signal
to turn on.
The system is waiting for the spindle one-rotation
signal in threading.
The system is waiting for the rotation of the
position coder in spindle feed per revolution.
When a dwell is being executed, “1” is displayed.
When it is not executed, “0” is displayed.
Diagnosis data related to servo motors
DGN 8
CNC internal state 2
[Data type]
Bit path
NAME
FOREGROUND READING
BACKGROUND READING
Internal state when “1” is displayed
Data is being input in the foreground.
Data is being input in the background.
RS232C interface output state
DGN 10
RS-232C interface output state
[Data type]
Bit
When data is being output through the RS-232C interface, "1" is indicated.
DGN 30
534
TH alarm character count (foreground edit)
B-64805EN/03
[Data type]
Diagnosis list
2-word
The position where the TH alarm occurred in foreground input is indicated by the number of
characters from the beginning of the block.
DGN 31
TH alarm character code (foreground edit)
[Data type]
Bit
The character code of the character at which the TH alarm occurred in foreground input is
indicated.
DGN 32
TH alarm character count (background edit)
[Data type]
2-word
The position where the TH alarm occurred in background input is indicated by the number of
characters from the beginning of the block.
DGN 33
TH alarm character code (background edit)
[Data type]
Bit
The character code of the character at which the TH alarm occurred in background input is
indicated.
Display language of the CNC screen
DGN 43
Number of the current display language of the CNC screen
[Data type]
Byte
The number of the current display language of the CNC screen is indicated.
The correspondence between languages and numbers is show below.
0 : English
1 : Japanese
2 : German
3 : French
4 : Chinese (Traditional)
5 : Italian
6 : Korean
7 : Spanish
8 : Dutch
9 : Danish
10 : Portuguese
11 : Polish
12 : Hungarian
13 : Swedish
14 : Czech
15 : Chinese (Simplified)
16 : Russian
17 : Turkish
18 : Bulgarian
19 : Romanian
535
Diagnosis list
B-64805EN/03
20 : Slovak
21 : Finnish
22 : Hindi
23 : Vietnamese
24 : Indonesian
25 : Slovenian
26 : Tamil
Details of serial Pulsecoder
DGN 200 #0
OFA
[Data type]
Bit axis
Overflow alarm
DGN 200 #1
FBA
[Data type]
Bit axis
Disconnection alarm
DGN 200 #2
DCA
[Data type]
Bit axis
Discharge alarm
DGN 200 #3
HVA
[Data type]
Bit axis
Overvoltage alarm
DGN 200 #4
HCA
[Data type]
Bit axis
Abnormal current alarm
DGN 200 #5
OVC
[Data type]
Bit axis
Over current alarm
DGN 200 #6
LV
[Data type]
Bit axis
Insufficient voltage alarm
DGN 200 #7
OVL
[Data type]
Bit axis
Overload alarm
DGN 201 #6
PCR
536
B-64805EN/03
[Data type]
Diagnosis list
Bit axis
The one-rotation signal of the position detector was caught before a manual reference position
return is performed. Since the manual reference position return grid was established, a manual
reference position return is enabled.
NOTE
This bit is valid only when the operation of the manual reference position return mode is
started.
DGN 201 #4
EXP
DGN 201 #7
ALD
[Data type]
Bit path
Overload alarm
Disconnection alarm
ALD
EXP
0
-
Amplifier overheat
1
-
Motor overheat
1
0
1
1
0
0
Disconnection of Built-in Pulsecoder
(hard)
Disconnection of separated type
Pulsecoder (hard)
Disconnection of Pulsecoder (software)
DGN 202 #0
SPH
[Data type]
Bit axis
Pulsecoder or feedback cable is faulty.
Counting of feedback cable is erroneous.
DGN 202 #1
CKA
[Data type]
Bit axis
Pulsecoder is faulty.
Internal block stopped.
DGN 202 #2
BZA
[Data type]
Bit axis
Battery voltage became 0.
Replace the battery and set the reference position.
DGN 202 #3
RCA
[Data type]
Bit axis
Pulsecoder is faulty.
The speed was incorrectly counted.
DGN 202 #4
PHA
Description
537
Diagnosis list
B-64805EN/03
[Data type]
Bit axis
Pulsecoder or feedback cable is faulty.
Counting of feedback cable is erroneous.
DGN 202 #5
BLA
[Data type]
Bit axis
Battery voltage is low (warning)
DGN 202 #6
CSA
[Data type]
Bit axis
Hardware of Pulsecoder is abnormal.
DGN 203 #4
PRM
[Data type]
Bit axis
A parameter failure was detected on the digital servo side. See the cause and measure
described in diagnosis No. 352.
DGN 203 #5
STB
[Data type]
Bit axis
Communication failure of Pulsecoder.
Transferred data is erroneous.
DGN 203 #6
CRC
[Data type]
Bit axis
Communication failure of Pulsecoder.
Transferred data is erroneous.
DGN 203 #7
DTE
[Data type]
Bit axis
Communication failure of Pulsecoder.
There is no response for communication.
DGN 204 #3
PMS
[Data type]
Bit axis
Feedback is not correct due to faulty Pulsecoder C or feedback cable.
DGN 204 #4
LDA
[Data type]
Bit axis
The digital servo software detected abnormal data on the
DGN 204 #5
538
MCC
Pulsecoder.
B-64805EN/03
Diagnosis list
[Data type]
Bit axis
Contacts of MCC of servo amplifier is melted.
DGN 204 #6
OFS
[Data type]
Bit axis
Abnormal current value result of A/D conversion of digital servo
Details of separate serial Pulsecoder alarms
DGN 205 #0
SPH
[Data type]
Bit axis
A soft phase data error occurred in the separate Pulsecoder.
DGN 205 #1
PMA
[Data type]
Bit axis
A pulse error occurred in the separate Pulsecoder.
DGN 205 #2
BZA
[Data type]
Bit axis
The battery voltage for the separate Pulsecoder is zero.
DGN 205 #3
CMA
[Data type]
Bit axis
A count error occurred in the separate Pulsecoder.
DGN 205 #4
PHA
[Data type]
Bit axis
A phase data error occurred in the separate linear scale.
DGN 205 #5
BLA
[Data type]
Bit axis
A low battery voltage occurred in the separate Pulsecoder.
DGN 205 #6
LDA
[Data type]
Bit axis
An LED error occurred in the separate Pulsecoder.
DGN 205 #7
OHA
[Data type]
Bit axis
Overheat occurred in the separate Pulsecoder.
539
Diagnosis list
B-64805EN/03
DGN 206 #5
STB
[Data type]
Bit axis
A stop bit error occurred in the separate Pulsecoder.
DGN 206 #6
CRC
[Data type]
Bit axis
A CRC error occurred in the separate Pulsecoder.
DGN 206 #7
DTE
[Data type]
Bit axis
A data error occurred in the separate Pulsecoder.
Connection system of scale
DGN 202 #7
SEM
Separate position detector is not used (semi-closed loop)
DGN 206 #0
LIN
Separate position detector is serial interface linear scale
DGN 206 #1
ROT
Separate position detector is serial interface rotary scale
[Data type]
Bit axis
SEM
ROT
LIN
Separate position detector (serial) (linear scale)
0
0
1
Separate position detector (serial) (rotary scale)
0
1
0
Separate position detector (AB phase)
0
0
0
Semi-closed mode
1
0
0
Details of illegal servo parameter setting alarms (on the CNC side)
DGN 280 #0
MOT
[Data type]
Bit axis
The motor type specified in parameter No. 2020 falls outside the predetermined range.
DGN 280 #2
PLC
[Data type]
Bit axis
The number of velocity feedback pulses per motor revolution, specified in parameter No. 2023,
No.42296 is zero or less. The value is invalid.
DGN 280 #3
PLS
540
B-64805EN/03
Diagnosis list
[Data type]
Bit axis
The number of position feedback pulses per motor revolution, specified in parameter No. 2024,
is zero or less. The value is invalid.
DGN 280 #4
DIR
[Data type]
Bit axis
The wrong direction of rotation for the motor is specified in parameter No. 2022 (the value is
other than 111 or -111).
DGN 281 #0
TDM
[Data type]
Bit axis
Four-winding motor drive (bit 7 of parameter No. 2211) or two-winding motor drive (bit 6 of
parameter No. 2211) is enabled when no option for tandem control is present.
Amount of positional deviation
DGN 300
Amount of positional deviation for each servo axis
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
0 to ±99999999
Displays the amount of positional deviation for each servo axis in the detection unit.
Machine position
DGN 301
Distance from reference position of an axis in detection unit
[Data type]
Real axis
Distance from the end of the deceleration dog to the first grid point
DGN 302
Distance from the end of the deceleration dog to the first grid point
[Data type]
[Unit of data]
[Valid data range]
Real axis
Machine unit
0 to ±99999999
NOTE
For the reference position setting without a dog, the distance from the beginning of the
reference position setting without a dog to the first grid point is assumed.
Reference counter
DGN 304
Reference counter amount for individual axis
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
–99999999 to 99999999
DGN 306
Machine coordinate value in the rectangular coordinate system of an angular axis
541
Diagnosis list
B-64805EN/03
DGN 307
Machine coordinate value in the rectangular coordinate system of an orthogonal axis
[Data type]
[Unit of data]
Real path
Machine unit
Displays the machine coordinate value in the rectangular coordinate system during angular
axis control.
You can change the display order with bit 7 (ADG) of parameter No. 8201.
Motor temperature information
DGN 308
Servo motor temperature (°C)
[Data type]
[Unit of data]
[Data range]
Byte axis
°C
0 to 255
The temperature of the coil of the servo motor is indicated. When the temperature reaches
140℃, a motor overheat alarm is issued.
DGN 309
Pulsecoder temperature (°C)
[Data type]
[Unit of data]
[Data range]
Byte axis
°C
0 to 255
The temperature of the printed circuit board in the Pulsecoder is indicated. When the
temperature reaches 100°C (approximately 85°C for the temperature of atmosphere in the
Pulsecoder), a motor overheat alarm is issued.
NOTE
1. Temperature information has the following error:
50°C~160°C ±5°C
160°C~180°C ±10°C
2. The temperature at which an overheat alarm is issued has an error of up to 5°C.
Cause that sets bit 4 (APZ) of parameter No. 1815 to 0
DGN 310 #0
PR1
[Data type]
Bit axis
One of the following parameters was changed:
No.1815#0, No.1815#1, No.1815#6, No.1817#3, No.1820, No.1821, No.1822, No.1823,
No.1850, No.1868, No.1869, No.1874, No.1875, No.1876, No.1878, No.1883, No.1884,
No.2022, No.2084, No.2085, No.2179, increment system for a rotary axis A type, No.11802#6,
No.11810
DGN 310 #1
PR2
[Data type]
Bit axis
Bit 1 (ATS) of parameter No. 8303 was changed. Alternatively, when bit 7 (SMA) of parameter
No. 8302 was set to 1, APZ of the axis to be synchronized together was set to 0.
DGN 310 #2
542
BZ1
B-64805EN/03
[Data type]
Diagnosis list
Bit axis
A battery voltage of 0 V was detected. (Inductosyn)
DGN 310 #3
BZ2
[Data type]
Bit axis
A battery voltage of 0 V was detected. (Separate position detector)
DGN 310 #5
ALP
[Data type]
Bit axis
The zero point was set by MDI when the α pulse coder had not rotate one or more turns.
Alternatively, the CNC could not obtain a correct value from the absolute pulse coder.
DGN 310 #6
DTH
[Data type]
Bit axis
An axis detach operation was performed by the controlled axis detach signal DTCH (G124) or
by setting bit 7 (RMV) of parameter No. 0012.
DGN 311 #0
AL1
[Data type]
Bit axis
An SV alarm (SV0301 to SV0305) was issued.
DGN 311 #1
AL2
[Data type]
Bit axis
When bit 1 (CRF) of parameter No. 1819 was set to 1, alarm SV0445, "SOFT DISCONNECT
ALARM", SV0447, "HARD DISCONNECT(EXT)", or SV0646, "ABNORMAL ANALOG
SIGNAL(EXT)", was detected.
DGN 311 #2
AL3
[Data type]
Bit axis
A battery voltage of 0 V was detected. (Built-in pulsecoder)
DGN 311 #3
AL4
[Data type]
Bit axis
543
Diagnosis list
B-64805EN/03
Alarm SV0367, "COUNT MISS(INT)", was detected.
DGN 311 #4
GSG
[Data type]
Bit axis
The status of broken-wire alarm ignore signal NDCAL (G202) changed from 1 to 0.
DGN 311 #5
XBZ
[Data type]
Bit axis
A battery voltage of 0 V or alarm SV0382, "COUNT MISS(EXT)", was detected. (Separate
serial position detector)
DGN 311 #6
DUA
[Data type]
Bit axis
When bit 1 (CRF) of parameter No. 1819 was set to 1, alarm SV0421, "EXCESS
ERROR(SEMI-FULL)", was detected.
DGN 311#7
BTL
[Data type]
Bit axis
A reference position return request occurred in the battery-less pulsecoder due to the following
cause.
In the case of pulsecoder serial number mismatch
When the control axis detach is enabled
When the machine coordinates move outside of the pulsecoder movable range
DGN 350 #0
PM1POS
[Data type]
Bit axis
Counting from the one closest to the CNC, the position detector is to the first SDU:
0:
Not connected
1:
Connected
DGN 350 #1
PM1ACC
[Data type]
Bit axis
Counting from the one closest to the CNC, the acceleration sensor is to the first SDU:
0:
Not connected
1:
Connected
DGN 350 #2
544
PM1TMP
B-64805EN/03
[Data type]
Diagnosis list
Bit axis
Counting from the one closest to the CNC, the temperature detection circuit is to the first SDU:
0:
Not connected
1:
Connected
DGN 350 #3
PM1CHK
[Data type]
Bit axis
Counting from the one closest to the CNC, the servo check interface unit is to the first SDU:
0:
Not connected
1:
Connected
DGN 350 #4
A_PHAL
[Data type]
Bit axis
An error occurred in the EEPROM of the αi pulsecoder (this is not an alarm)
DGN 350 #5
ALMACC
[Data type]
Bit axis
An alarm was generated by the acceleration sensor
DGN 350 #6
ALMTMP
[Data type]
Bit axis
An alarm was generated by the temperature detection circuit
DGN 351 #0
PM2POS
[Data type]
Bit axis
Counting from the one closest to the CNC, the position detector is to the second SDU:
0:
Not connected
1:
Connected
DGN 351 #1
PM2ACC
[Data type]
Bit axis
Counting from the one closest to the CNC, the acceleration sensor is to the second SDU:
0:
Not connected
1:
Connected
545
Diagnosis list
B-64805EN/03
DGN 351 #2
PM2TMP
[Data type]
Bit axis
Counting from the one closest to the CNC, the temperature detection circuit is to the second
SDU:
0:
Not connected
1:
Connected
DGN 351 #3
PM2CHK
[Data type]
Bit axis
Counting from the one closest to the CNC, the servo check interface unit is to the second SDU:
0:
Not connected
1:
Connected
Details of invalid servo parameter setting alarms (on the servo side)
DGN 352
Detail number for illegal servo parameter setting alarm
[Data type]
Word axis
Indicates information that can be used to identify the location (parameter) and cause of an
illegal servo parameter setting alarm (servo alarm No. 417).
This diagnosis information is valid when the following conditions are satisfied.
Servo alarm No. 417 has occurred.
Bit 4 of diagnosis No. 203 (PRM) = 1
For the displayed detail numbers and corresponding causes and actions, see the table below.
In addition, refer to "AC SERVO MOTOR αi-B/αi series, AC SERVO MOTOR βi-B/βi series,
LINEAR MOTOR LiS-B/LiS series, DD MOTOR DiS-B/DiS series PARAMETER MANUAL" (B65270EN) for more detailed information on measures.
Detailed descriptions about invalid servo parameter setting alarms
Detail
numb
er
Parameter
number
0092
2009#2
0233
2023
0234
2023
0243
2024
546
Cause
A function which is not supported by the 500iA Series is used.
When bit 0 of No.2000 is set to 1, the number
of velocity pulses exceeds 13100.
When a DD motor is used, a value smaller
than 512 is set as the number of velocity
pulses.
When bit 0 of No.2000 is set to 1, the number
of position pulses exceeds 13100.
Action
Set bit 2 of parameter No. 2009 to 0.
Use number of velocity pulses (extended) No.
42296. Even if bit 0 of No.2000 is set to 1, the
value of No.42296 is not multiplied by 10
internally.
Set 512 or a greater number as the number of
velocity pulses.
Correct the number of position pulses so that
it is within 13100. Use the position feedback
pulses conversion coefficient (parameter No.
2185).
B-64805EN/03
Diagnosis list
Detail
numb
er
Parameter
number
0346
2034
An overflow occurred in the vibration
suppression control setting.
0434
0435
2043
The internal value of the velocity loop integral
gain overflowed.
0443
0444
0445
2044
The internal value of the velocity loop
proportional gain overflowed.
0474
0475
2047
The internal value of the observer parameter
(POA1) overflowed.
0523
2052
0524
2006#3
2052
42064
0534
0535
2053
The excess speed alarm detection speed
(No.2052) is not set.
This alarm occurs when all of the following
conditions are met:
- Multiple winding motor drive (No.42064) or
bit 3 of No. 2006 is set to 1
- Over-speed alarm level (No. 2052) is set to
0
The internal value of a parameter related to
dead band compensation overflowed.
0544
0545
2054
The internal value of a parameter related to
dead band compensation overflowed.
0686
0687
0688
2068
The internal value of the feedforward
coefficient overflowed.
0694
0695
0696
0699
2069
The internal value of the velocity feedforward
coefficient overflowed.
Alternatively, bit 3 of parameter No. 2282 is
set to 1 and the number of position pulses is
set to a value less than or equal to 256.
Decrease the velocity feedforward coefficient
(No.2069). Alternatively, set bit 3 of parameter
No. 2203 to 0. If the alarm is not canceled
after the velocity feedforward coefficient is set
to 0, set bit 3 of parameter No. 2282 to 0.
0754
0755
2075
The setting for this parameter has overflowed.
This parameter is not used at present. Set 0.
0764
0765
2076
The setting for this parameter has overflowed.
This parameter is not used at present. Set 0.
0843
2084
A positive value is not set as the flexible feed
gear numerator. Alternatively, the following
condition exists: Feed gear numerator >
denominator × 16
0853
2085
0883
2088
A positive value is not set as the flexible feed
gear denominator.
For an axis with a serial type separate
detector, a value exceeding 100 is set as the
machine velocity feedback coefficient.
0884
0885
0886
2088
The internal value of the machine velocity
feedback coefficient has overflowed.
Set a positive value as the flexible feed gear
numerator.
Alternatively, satisfy the following condition:
Feed gear numerator ≤ denominator × 16
(except for phase A-/B-specific separate
detector).
Set a positive value as the flexible feed gear
denominator.
For an axis with a serial type separate
detector, the upper limit of the machine
velocity feedback coefficient is 100. Correct
the coefficient so that it does not exceed 100.
Decrease the machine velocity feedback
coefficient. Alternatively, use the vibration
damping control function that has an
equivalent effect.
Cause
Action
Check whether correct values are set for the
number of velocity pulses, number of position
pulses, and FFG.
Decrease the value of the velocity loop
integral gain parameter.
Use the function for changing the internal
format of the velocity loop proportional gain
(bit 6 of parameter No. 2200). Alternatively,
decrease the parameter setting.
Correct the setting to
(-1) × (desired absolute value)/10
.
Set the excess speed alarm detection speed
(No.2052).
When multiple winding motor drive
(No.42064) or bit 3 of No. 2006 is set to 1,
also set the over-speed alarm level (No.
2052).
Decrease the setting to the extent that the
illegal servo parameter setting alarm is not
caused.
Decrease the setting to the extent that the
illegal servo parameter setting alarm is not
caused.
Decrease the feedforward coefficient
(No.2068), or set No.2000#4 (expansion of
position gain range) to 1.
547
Diagnosis list
Detail
numb
er
Parameter
number
B-64805EN/03
Cause
Action
0926
0927
0928
2092
The internal value of the advanced preview
feedforward coefficient overflowed.
Decrease the advanced preview feedforward
coefficient (No.2092), or set No.2000#4
(expansion of position gain range) to 1.
0994
0995
0996
2099
The internal value for N pulse suppression
overflowed.
Disable the N pulse suppression function.
Alternatively, decrease the parameter setting
so that no overflow will occur.
1033
2103
Set the same value.
1123
2112
1182
2118
2078
2079
There is a difference in retract distance under
unexpected disturbance torque between the
position tandem master and slave axes. (If the
same-axis retract function is in use)
Although a linear motor is used, the AMR
conversion coefficient parameter is not input.
The dual position feedback conversion
coefficient has not been specified.
1183
2118
Although an analog SDU is used, the function
for monitoring the difference in error between
the semi-closed and full-closed modes is
disabled.
1284
1285
2128
1294
1295
2129
1393
2139
When a small value is set as the number of
velocity pulses, the internal value of a
parameter related to current control overflows.
When a large value is set as the number of
velocity pulses, the internal value of a
parameter related to current control overflows.
The AMR offset setting value of a linear motor
exceeds ±45.
Set the level at which the difference in error
between the semi-closed and full-closed
modes becomes too large (parameter
No.2118).
If the monitoring function cannot be enabled
due to the machine configuration, set the bit
for disabling the semi-full error monitor (bit 0
of parameter No.2565) to 1.
Decrease the value in this parameter to the
extent that the alarm is not caused.
1446
1447
1448
2144
Feed-forward coefficient for cutting
overflowed.
1454
1455
1456
1459
2145
Velocity feed-forward coefficient for cutting
overflowed.
Decrease the velocity feed-forward coefficient
(No.2145). Alternatively, set bit 3 of parameter
No. 2203 to 0. If the alarm is not canceled
after the velocity feedforward coefficient is set
to 0, set bit 3 of parameter No. 2282 to 0.
1493
2149
A value greater than 6 is specified in this
parameter.
1503
2150
A value equal to or greater than 10 is set.
Only 6 or less can be specified in this
parameter. Change the setting to 6 or below
6.
Set a value less than 10.
1786
2212#6
2213#6
2178
Bit 6 of No. 2212 or bit 6 of No. 2213 is set to
1, and No. 2178=0 is set.
Set bit 6 of No. 2212 or bit 6 of No. 2213 to 0,
or set No.2178 to value other than 0.
1793
2179
1853
2185
A negative value or a value greater than the
setting of parameter No. 1821 is set.
A negative value or a value greater than onefourth of velocity pulses is set.
Set a positive value less than the setting of
parameter No. 1821.
Set a positive value that is smaller than onefourth of velocity pulses.
548
Set the AMR conversion coefficient.
Specify the dual position feedback conversion
coefficient.
When the value set in this parameter is
resolved to the form a × 256 + b, set a smaller
value in a again.
Keep the setting of this parameter within ±45.
Alternatively, set bit 0 of parameter No. 2270
to 1 to increase the setting range of the AMR
offset, and then specify the parameter
anywhere within ±60.
Decrease the feed-forward coefficient for
cutting (No.2144), or set No.2000#4
(expansion of position gain range) to 1.
B-64805EN/03
Diagnosis list
Detail
numb
er
Parameter
number
2203
2220#0
2233
2223#6
2235
2223#5
2632
2263
The setting of the detection unit (No. 2263) is
disabled.
2731
2273#1
42248
The setting of the velocity loop integrator copy
(bit 1 of No.2273,No.42248) is incorrect.
2765
2276#4,5
2780
2277#5,6,7
2278#0,2,4
40148
2781
2277#5,6,7
2278#1,3,4
40149
2782
2277#5,6,7
2278#0,4
40148
2783
2277#5,6,7
2278#1,4
40149
A setting is made to connect two analog
monitor units (current input, Type-C) (bits 4
and 5 of parameter No. 2276 are both set to
1).
When the first SDU unit is not used
(No.40148=0), a setting is made to connect a
detector (acceleration sensor, temperature
detection circuit, or analog check interface
unit) to the first SDU unit.
When the second SDU unit is not used
(No.40149=0), a setting is made to connect a
detector (acceleration sensor, temperature
detection circuit, or analog check interface
unit) to the second SDU unit.
Any of the following settings is made:
For use with the first SDU unit, both of
an acceleration sensor and temperature
detection circuit are enabled.
Settings are made to use the first SDU
unit (No.40148>0), disable an
acceleration sensor (bits 5, 6, 7 of No.
2277=0,0,0), and read acceleration data
from the second unit (bit 1 of No.
2278=1).
Any of the following settings is made:
For use with the second SDU unit, both
of an acceleration sensor and
temperature detection circuit are
enabled.
Settings are made to use the second
SDU unit (No.40149>0), disable an
acceleration sensor (bits 5, 6, 7 of No.
Cause
Action
If pole detection is enabled (bit 7 of No.
2213=1) and a non-binary detector is enabled
(bit 0 of No. 2220=1), an illegal servo
parameter setting alarm is issued when any of
the following is set:
AMR conversion coefficient 1 ≤ 0
AMR conversion coefficient 2 ≤ 0
AMR conversion coefficient 2 > 512
(The settable range is 1 (2 poles) to 512
(1024 poles).)
This alarm is issued when parameter No.
1023 is not set to 16n + 1 for the master axis
of multi-axis tandem.
Multi-axis tandems cannot be used.
Set the AMR conversion coefficients correctly.
Set bit 6 of parameter No. 2223 to 0.
Set bit 5 of parameter No. 2223 to 0. Use No.
42248 for integrator copy and No. 42249 for
synchronized alarm monitoring to enable the
function on multiple axes.
Take one of the following actions:
1. Set a value in parameter No. 2263.
2. Disable the lifting function against gravity
and the post-servo-off travel distance
monitor function.
3. Use CNC software that supports the
function for enabling the detection unit to
be posted to the servo software.
Check the odd and even axes for bit 1 of
No.2273 and the servo axis group for
No.42248 to specify the axes that can be set.
Eliminate the causes shown at left.
Check the FSSB setting (No.40148) or the
detector setting (bits 0, 2, and 4 of No. 2278).
Check the FSSB setting (No.40149) or the
detector setting (bits 1, 3, and 4 of No. 2278).
Check the settings of the acceleration sensor
and temperature detection circuit.
Check the settings of the acceleration sensor
and temperature detection circuit.
549
Diagnosis list
Detail
numb
er
B-64805EN/03
Parameter
number
Cause
2784
1815#1
2277#5,6,7
2278#0,1,4
2785
1815#1
2277#5,6,7
2278#0,4
2277=0,0,0), and read acceleration data
from the second unit (bit 1 of No.
2278=1).
At the time of full-closed system setting, a
detector other than a separate position
detector is connected (with the first/second
SDU unit).
At the time of full-closed system setting, a
detector other than a separate position
detector is connected (with the first SDU unit).
2786
1815#1
2277#5,6,7
2278#1,4
2787
2278#0,#1
2788
1815#1
2277#5,6,7
2278#4
2278#0,1
40148
40149
A setting is made to connect multiple sensors
to a single SDU.
2815
2281#5
2014#5
2292#7
2606
2843
2284#3
3002
2300#3,#7
Any of the following functions, which cannot
be used with the energy charge unit
(Mechanical), is used:
Torque characteristic switching (bit 5 of
No. 2014 = 1)
Interactive force compensation (bit 7 of
No. 2292 = 1)
Alternatively, the parameter for specifying
the drive axis (No. 2606) is set incorrectly.
Any of the following settings is made:
1. Pressure and position control (bit 3 of
No. 2284) is enabled for the evennumbered axis.
2. When pressure and position control is
enabled for the odd-numbered axis, the
even-numbered axis is not any of the
following:
Multi-winding sub-axis
Torque tandem sub-axis
Dummy axis
The αiCZ detection circuit and linear motor
position detection circuit do not support
overheat signal connection.
3012
2301#2,#7
3553
2355
550
At the time of full-closed system setting, a
detector other than a separate position
detector is connected (with the second SDU
unit).
A setting is made to connect two temperature
detection circuits.
Hardware (PS, SV) that does not support DC
link voltage information output is connected,
but bit 2 of No. 2301 is set to 1.
Alternatively, when bit 7 of No. 2301=1, the
CNC software does not support the torque
control setting range extension function.
The value 4 or a smaller number is set.
Action
Modify the setting of the detector.
Modify the setting of the detector.
Modify the setting of the detector.
Only one temperature detection circuit can be
connected. Modify the setting so that data is
read from one of the first and second SDU
units.
Check the settings of the parameters related
to sensor connection.
Disable these functions.
Alternatively, set parameter No. 2606
correctly.
1. For the even-numbered axis, set bit 3 of
parameter No. 2284 to 0.
2. Set the even-numbered axis to any of
these axes.
Replace the αiCZ detection circuit and linear
motor position detection circuit with those
circuits that support overheat signal
connection. Alternatively, modify the setting
so that the overheat signal is read from a DI
signal (bit 3 of parameter No. 2300=0).
Set bit 2 of No. 2301 to 0. Alternatively, use
CNC software that supports the torque control
setting range extension function.
Set the value 5 or a greater number.
B-64805EN/03
Detail
numb
er
Parameter
number
Diagnosis list
Cause
Action
3603
2113
2360
2363
2366
The value 95 or a smaller number is set.
* Parameter No. 2366 is used only when
resonance elimination filter L is disabled.
Set a value of 96 or greater. Alternatively, if
no resonance elimination filter is used, set all
of the center frequency, band width, and
dumping to 0.
3663
2366
When using resonance elimination filter L, set
5 or a larger value for parameter No. 2366.
3722
2372
Resonance elimination filter L is enabled and
(bit 1 of parameter No. 2221 is set to 1) and
the value set for parameter No. 2366 is 4 or
smaller.
The EGB exponent setting is made.
4024
4025
4029
2402
The internal value of the torsion torque
compensation coefficient overflowed.
4224
40164
2422#4
2590
2591
Disable servo HRV+ control (set bit 4 of
parameter No. 2422 to 0), or set the current
gain.
4291
2429#1
4374
2437#4
4436
2443#6
4553
2455
When servo HRV+ control is enabled (bit 4 of
parameter No. 2422 is set to 1), the current
gain is set to 0 (parameter Nos. 2590 and
2591). Alternatively, HRV+ control is enabled
(bit 4 of parameter No. 2422 is set to 1) for an
axis for which HRV2 control is enabled.
An attempt was made to use FSSB highspeed rigid tapping with either of the following
functions. Bit 1 of parameter No. 2429 is set
to 1.
EGB (FSSB method)
Servo/spindle synchronous control
(FSSB method)
The linear scale supporting the αi interface
cannot be used. The possible causes are:
In semi-closed mode, the αi interface is
not used on the semi-closed side.
Alternatively, a linear motor is not used.
In full-closed mode, the αi interface is not
used on the full-closed side.
The 2048-magnification interpolation
circuit (bit 0 of parameter No. 2274) is
enabled.
Compensation data mode is enabled (bit 6 of
parameter No. 2443 is set to 1) when servo
learning oscillation is applied.
A negative value is set.
4563
2456
A value not within 0 to 12 is set.
Set a value within 0 to 12.
4643
2464
Set a value within the valid data range for the
insulation resistance alarm level (parameter
No. 2464).
4793
2281#5
2479
5123
2512
The set insulation resistance alarm level
(parameter No. 2464) is not within the valid
data range.
[Valid data range] 6 to 1000, 32767
When parameter No. 2464 is set to 32767,
the level is not detected.
When the energy charge unit (Mechanical) is
enabled (bit 5 of parameter No. 2281 is set to
1), the power threshold value (No. 2479) is
set to a negative value.
The learning bandwidth (No. 2512) is outside
the setting range.
Set 0 for the EGB exponent setting
(parameter No. 2372).
Decrease the torsion torque compensation
coefficient.
FSSB high-speed rigid tapping cannot be
used together with these functions. Eliminate
the causes shown at left.
Eliminate the causes shown at left.
When applying servo learning oscillation,
disable the compensation data mode (set bit 6
of parameter No. 2443 to 0).
Set the value 0 or a greater number.
Set a positive value.
Set the value within the following range for
each velocity control cycle.
Velocity control cycle 1 ms: 25, 50, 75, ..., 350
Hz (in 25 increments)
551
Diagnosis list
Detail
numb
er
Parameter
number
B-64805EN/03
Cause
Action
Velocity control cycle 0.5 ms: 50, 100, 150, ...,
700 Hz (in 50 increments)
Velocity control cycle 0.25 ms: 100, 200,
300, ..., 1400 Hz (in 100 increments)
To disable learning control, set to 0
regardless of the velocity control cycle.
Correct the value within the valid data range
(between 0 and 255).
For details on PS control axis setting, refer to
"FANUC AC SERVO MOTOR αi series,
FANUC AC SPINDLE MOTOR αi series,
FANUC SERVO AMPLIFIER αi series
MAINTENANCE MANUAL".
Set bit 0 of parameter No. 2568 is set to "0".
5573
2557
The value specified for parameter No. 2557
(PS control axis specification) is not within the
valid data range.
5680
2568#0
5681
2568#1
5720
5721
5722
5723
5724
5725
5726
5727
2572
Bit 0 of parameter No. 2568 is set to "1" for
the axis that is set to connect a separate
detector I/F unit (SDU) and servo check
interface unit (SVCK).
Bit 1 of parameter No. 2568 is set to "1" for
the axis that is set to connect a separate
detector I/F unit (SDU) and servo check
interface unit (SVCK).
A setting for a PS control axis is made for a
non-PS control axis. (No.2572)
5730
5731
5732
5733
5734
5735
5736
5737
2573
A setting for a PS control axis is made for a
non-PS control axis. (No.2573)
For other axes, set this parameter to 0.
5740
2574
2560#4
The settings of parameter No. 2574 and bit 4
of parameter No. 2560 are invalid.
Set the motor-specific standard parameters.
5953
2595
Set a value within the valid data range for
parameter No. 2595.
6063
2606
6114
6115
6116
6119
2611
The value of parameter No. 2595 is not within
the valid data range.
[Valid data range] 0 to 9999
The interactive force compensation parameter
(No. 2606) is not within the valid data range.
The internal value of the velocity feed-forward
coefficient for FSSB high-speed rigid tapping
overflowed.
6402
1815#1
2640
2641
2642
Resonance elimination filter 5 (Nos. 2640 to
2642) is applied to the axes that cannot be
used.
Resonance elimination filter 5 is available only
for semi-closed loop, HRV3 (velocity control
cycle speedup) or HRV4. If none of these
apply, set all parameters of resonance
elimination filter 5 to 0.
552
Set bit 1 of parameter No. 2568 is set to "0".
For other axes, set this parameter to 0.
Set a value within the valid data range.
Decrease the velocity feed-forward coefficient
for FSSB high-speed rigid tapping.
B-64805EN/03
Diagnosis list
Detail
numb
er
Parameter
number
6713
6723
6733
6743
6753
6763
6773
6783
6793
6803
6813
6823
6833
6843
6853
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
A setting for a PS control axis is made for a
non-PS control axis. (No.2671 to No.2685)
For other axes, set this parameter to 0.
6977
2697#7
The servo amplifier with built-in brake in use
is αi-B, βi-B or earlier.
6978
2697#7
6996
2699#6
2427#7
7351
2735#1,2,3
7355
2735#5
8213
1821
8254
8255
8256
1825
The brake mode command to the amplifier
does not match the brake mode command
from the amplifier.
A function that cannot be used in combination
with the feedrate command limit function has
been set.
Unavailable combination or servo amplifier
does not support overheat/temperature
monitoring via amplifier.
For the emergency stop timer extension
function, non-compliant servo amplifier
software is used.
A positive value is not set in the reference
counter capacity parameter.
A position gain of 0 is set, or the internal
position gain value has overflowed.
Change the servo amplifier to αi-D or later.
Or set bit 7 of No. 2697 to 0.
If the servo amplifier supports the use of the
built-in brake, the servo amplifier is
malfunctioning. Replace the servo amplifier.
Set 2699#6 to 0.
9053
1815#1
2016#4
40148
40149
At the time of full-closed system setting, no
separate detector interface unit is set.
Set a separate detector interface unit.
10010
10016
10019
2200#0
The internal value of a parameter used to
detect "unmatched feedback alarm" has
overflowed.
10033
2004
10053
2018#0
10062
2209#4
Illegal control cycle setting
This error occurs if automatic modification is
carried out for the control cycle.
When a linear motor is used, the scale
reverse connection bit is set.
The amplifier used does not support the HC
alarm prevention function.
Check the parameter (flexible feed gear, the
number of position pulse and the number of
velocity pulse) and the direction of position
feedback. If both of them are correct, set
unmatched feedback alarm to disable.
(No.2200#0=1)
Correct this parameter related to interrupt
cycle setting.
Cause
Action
Set up the correct combination.
Prepare the supported servo amplifier
software or set bit 5 of parameter No. 2735 to
0.
Set a positive value in this parameter.
Set a value other than 0 (when setting = 0).
When the linear motor is used, the scale
reverse connection bit cannot be used.
When you use the current amplifier
continuously, set the function bit shown to the
left to 0.
553
Diagnosis list
Detail
numb
er
10092
10093
B-64805EN/03
Parameter
number
2004
40164
Cause
This alarm is issued when an invalid control
cycle is set.
Different control cycles are set within one
servo CPU.
When HRV4 is enabled, a detector that does
not support HRV4 is used.
When HRV4 is enabled, a servo amplifier that
does not support HRV4 is connected.
Action
When using the HC alarm prevention function,
use an appropriate amplifier that supports the
function.
Change the control cycle setting to HRV2,
HRV3 or HRV4.
Set the same control cycle for axes controlled
by one servo CPU.
Replace the detector with a detector
supporting HRV4. Alternatively, disable
HRV4.
Replace the servo amplifier with a servo
amplifier supporting HRV4. Alternatively,
disable HRV4.
The Series-500i does not allow HRV1 setting.
Set HRV2, HRV3 or HRV4.
10103
2004
40164
HRV1 is set.
10113
40164
An axis for which HRV3 is specified exists on
the same optical cable. Review the placement
of the amplifier, or disable HRV3.
10123
40164
10123
40164
10133
40164
10202
2277#5,6,7
2278#0,2,4
Current cycle mismatch alarm.
This alarm is issued if the specified current
cycle does not match the actual setting.
Alarm for indicating the disability of HRV3
setting.
This alarm is issued when the axis supports
HRV3 but the other axis of the pair does not
support HRV3.
When HRV4 is set, this alarm is issued if any
of the following conditions is met.
Servo software not supporting HRV4 is
used.
The same FSSB system includes axes
with HRV4 setting and axes with HRV2
or HRV3 setting.
The limitation in the number of axes is
not observed. (In HRV4 control, four
axes/servo CPU is set .)
This alarm is issued when HRV3 or HRV4 is
set, but the amplifier does not support these
control types.
The ID of the detector connected to the first
SDU unit differs from the parameter setting.
10212
2277#5,6,7
2278#1,3,4
Check the detector-related parameter or the
state of detector connection.
10221
2292#6,7
2293#6
The ID of the detector connected to the
second SDU unit differs from the parameter
setting.
The interactive force compensation function is
used, but the CNC does not support detection
unit information.
When using the SERVO HRV3 Control as a
5-axis/servo CPU, only 3 axes can be fully
closed.
A combination of software that does not
support improving the response of gap control
is set to improve the response of gap control.
Bit 6 (FSSBSTO) of parameter No.41085 set
to 1 and bit 1 (STO) of parameter No.2436 set
to 1. Or, there is hardware connected that
FSSBSTO cannot use.
Bit 7 (SBC) of parameter No.41085 set to 1
and bit 7 (amplifier brake circuit) of parameter
10300
10400
29704#0
10856
2436#1
41085#6
10857
2697#7
41085#7
554
Eliminate the cause of the disability in setting
the other axis. Alternatively, cancel the HRV3
setting.
Eliminate the causes listed on the left.
Alternatively, cancel the HRV4 setting.
HRV3 or HRV4 is unusable for the axis on
which the alarm was issued.
Check the detector-related parameter or the
state of detector connection.
Set the detection unit.
Keep fully-closed axes to 3.
Check the version number of the servo control
software and CNC system software. (A41273)
Check the hardware configuration and set 0 to
the unused function.
Check the hardware configuration and set 0 to
the unused function.
B-64805EN/03
Detail
numb
er
Diagnosis list
Parameter
number
20643
2020
42064
20803
2696#3
40164
42080
42081
42082
22493
42249
Cause
Action
No.2697 set to 1. Or, there is hardware
connected that the SBC cannot use.
For driving a motor with multiple windings
(No.42064)
1. All No. 42064 of the multiple windings
are not set to 1.
2. The motor No. 2020 of the multiple
windings does not match.
Resonance elimination filter 6 (Nos. 42080 to
42082) is applied to the axes that cannot be
used.
The setting of the axis for synchronized alarm
monitoring (No. 42249) is set to a value that
cannot be specified.
1. No. 42064 for all multiple winding motor
drive shafts should be the same.
2. Use the same motor No. 2020 and set
the same standard parameters.
Resonance elimination filter 6 is available only
for HRV3 (velocity control cycle speedup) or
HRV4. If none of these apply, set all
parameters of resonance elimination filter 6 to
0.
Set the axis of the configurable servo axis
group to No. 42249.
Supplementary: Details of an illegal learning control parameter
Set parameter No. 2115 to 0, and parameter No. 2151 to 6265 to change the value of DGN No. 353 to a binary
number. You can find a detailed cause from the bit position of the obtained binary number at which 1 is set.
Position
Cause
B3
The band-pass filter (No. 2512) is not in the range.
B4
The profile number (No. 2511) is not in the range.
B5
The specified data period (No. 2517, 2519, 2521, 2523, or 2525) is not in the range.
B6
The total number of profiles (No. 2510) is not in the range.
B7
This alarm is issued when G05 starts during a memory clear operation.
B8
This alarm is issued when the total number of profiles (No. 2510) is not 0, and the profile number (No.
2511) is 0.
This alarm is issued when the automatically-set thinning shift value exceeds the range because the
specified data period is too long.
B9
DGN 353
Servo internal data 1
DGN 354
Servo internal data 2
[Data type]
Word axis
Information for servo maintenance and tuning is displayed. The content displayed will vary
depending on the parameter settings.
1) If parameter bit 0 (ITDOUT) of parameter No. 2294 is 1.
The amplitude and offset information for the αiCZ sensor is displayed.
Diagnosis No. 353: Sensor head 1 amplitude/offset Information
Diagnosis No. 354: Sensor head 2 amplitude/offset Information
Thousands: Indicates the number of the sensor head.
1: Sensor head 1, 2: Sensor head 2
Hundreds: The amplitude value is indicated as level 1 to 9.
The default setting is 3 to 7.
Tenths: The offset value of phase A is indicated on a scale of 1 to 9.
The default setting is 3 to 7.
Ones: The offset value of phase A is indicated on a scale of 1 to 9.
The default setting is 3 to 7.
2) If parameter bit 0 (ACCOUT) of parameter No. 2290 is 1.
555
Diagnosis list
B-64805EN/03
Diagnosis No. 354 displays the acceleration feedback of the acceleration sensor.
*
For details, refer to the acceleration monitor function in the FANUC AC SERVO MOTOR
αi/βi series Parameter Manual (B-65270EN).
3) Other
The internal data of the servo control software is displayed. The displayed content will vary
depending on the series/edition of the servo control software and the settings for parameter
numbers 2115, 2151, 2152, and 2153.
NOTE
1. When No.2294#0=0, other information is displayed.
2. Please check the values displayed on the diagnosis screen above while rotating the
tool.
3. After checking, return to No.2294#0=0.
DGN 355
Communication alarm ignore counter (separate type)
DGN 356
Link processing counter (built-in type)
DGN 357
Link processing counter (separate type)
[Data type]
Word axis
The number of times a communication error occurred during serial communication with the
detector is indicated.
Data transmitted during communication is guaranteed unless another alarm occurs. However, if
the counter value indicated in this diagnosis information increases in a short period, there is a
high probability that serial communication is disturbed by noise. So, take sufficient measures to
prevent noise.
* For details, refer to a relevant manual on FANUC SERVO MOTOR αi series.
DGN 358 #6
*ESP
[Data type]
Word axis
Converter emergency stop state released
For details, refer to a relevant manual on FANUC SERVO MOTOR αi series.
DGN 358 #10
CRDY
[Data type]
Word axis
Converter ready
DGN 358 #12
INTL
[Data type]
Word axis
DB relay released
DGN 358 #13
556
DRDY
B-64805EN/03
[Data type]
Diagnosis list
Word axis
Amplifier ready (amplifier)
DGN 358 #14
SRDY
[Data type]
Word axis
Amplifier ready (software)
DGN 359
Communication alarm neglect counter (built-in type)
[Data type]
Byte axis
The diagnosis information is the same as that of diagnosis No. 355.
See the descriptions in diagnoses No.355 to 357.
DGN 360
Cumulative value of specified pulses (NC)
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
-2147483648 to 2147483647
Cumulative value of move commands distributed from the CNC since power-on is indicated.
DGN 361
Compensation pulses (NC)
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
-2147483648~2147483647
Cumulative value of compensation pulses (backlash compensation, pitch error compensation,
and so on) distributed from the CNC since power-on is indicated.
DGN 362
Cumulative value of specified pulses (SV)
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
-2147483648~2147483647
Cumulative value of move pulses and compensation pulses received by the servo system since
power-on is indicated.
DGN 363
Cumulative feedback (SV)
[Data type]
[Unit of data]
[Data range]
2-word axis
Detection unit
-2147483648~2147483647
557
Diagnosis list
B-64805EN/03
Cumulative value of positional feedback pulses the servo system received from the pulse coder
since power-on is indicated.
DGN 365
Total travel distance (clearable)
DGN 366
Total travel distance
[Data type]
[Unit of data]
[Data range]
2-word axis
m, 100 inch, 360 degrees
0 to 16909320 (when unit of data is 100 inch)
0 to 4294967295 (when unit of data is 360 degrees)
Displays the total travel distance of the feed axis.
When the feed axis total travel distance clear signal TDC1 to TDC8 <Gn726> is changed from
1 to 0, diagnosis data (No. 365) becomes 0. When the diagnosis data (No. 366) exceeds the
upper limit, it becomes 0.
The feed axis total travel
distance clear signal TDCx
<Gn726> becomes 1 from 0.
Diagnosis data (No.
365)
Diagnosis data (No.
366)
Travel distance limit is
exceeded
becomes 0
is continuously at the upper limit
does not become 0
becomes 0
NOTE
1. In case of rotation axis, unit of data is 360 degrees. In case of linear axis, unit of data is
m or 100 inch according to the least command increment of the machine.
2. When bit 3 (ETD) of parameter No. 8906 is 1, the travel distance is integrated.
3. When bit 3 (ETD) of parameter No. 8906 is 0, the travel distance is not integrated but
previously integrated values are displayed.
4. This diagnosis parameter is displayed as radius value. Diameter/radius specification
does not affect this parameter.
DGN 379
MCC off test number
[Data type]
[Unit of data]
[Valid data range]
Word path
None
0 to 128
The MCC off test number is displayed.
When not in MCC off test mode, the number is displayed as 0. When the test mode signal OPT
is inputted and MCC off test mode is activated, the test number increases as the MCC off test
progresses from 0 to 1, 2, etc., and stops at 128 when the MCC off test completes. When the
test mode signal OPT is set to 0 and MCC off test mode is deactivated, the test number is
cleared to 0.
Diagnosis data related to the induction absolute position detector
DGN 380
Difference between the absolute position of the motor and offset data
[Data type]
[Unit of data]
2-word axis
Detection unit
558
B-64805EN/03
Diagnosis list
The remainder resulting from the division is displayed.
DGN 381
Offset data from the Inductosyn
[Data type]
[Unit of data]
2-word axis
Detection unit
Off set data is displayed when CNC calculates the machine position.
Diagnosis data related to the serial spindles
DGN 403
Temperature of spindle motor
[Data type]
[Unit of data]
[Data range]
Byte spindle
°C
0 to 255
The temperature of the winding of the spindle motor is indicated.
This information can be used to determine the overheat alarm of the spindle. (The temperature
that causes an overheat alarm varies from motor to motor.)
NOTE
1. Temperature information has the following error:
50°C to 160°C : ±5°C
160°C to 180°C : ±10°C
2. The indicated temperature and the temperature causing an overheat alarm have the
following error:
160°C or below: 5°C max.
160 to 180°C: max. 10°C
DGN 410
Spindle load meter indication [%]
[Data type]
[Unit of data]
Word spindle
%
DGN 411
Spindle motor feedrate (word)
[Data type]
[Unit of data]
Word spindle
min-1
DGN 417
Spindle position coder feedback information
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 418
Positional deviation of spindle in position loop mode
[Data type]
[Unit of data]
2-word spindle
Detection unit
Amount of positional deviation during position loop control of each spindle
The display of diagnostic data is a direct display of information obtained from the serial spindle
control unit.
During Cs contouring control is, it functions as a position error display for the Cs contour axis.
559
Diagnosis list
B-64805EN/03
In addition, it can also be checked by the servo error display (Diagnostic Data No.300) of the
axis that is used as the Cs contouring control axis.
DGN 425
Synchronization error of each spindle
[Data type]
[Unit of data]
2-word spindle
Detection unit
Indicates the absolute value of the synchronization error for each spindle when the spindles are
in synchronous mode. Synchronization error values are displayed on the slave spindle.
DGN 445
Spindle position data
[Data type]
[Unit of data]
[Valid data range]
2-word spindle
Pulse
Follows the setting of bit 0 (ORPUNT) of parameter No. 4542. (Refer to following table.)
Bit 0 (ORPUNT) of parameter No. 4542
Data range
0
0 to 4095
1
0 to 32767
Position coder signal pulse data from the one-rotation signal is indicated as the position data of
the spindle.
This data is valid when bit 1 of parameter No. 3117 is set to 1.
To display spindle position data, spindle orientation must be performed once.
DGN 449
Spindle position data (angle)
[Data type]
[Unit of data]
[Valid data range]
Real spindle
See below table
0 to 359.999[deg]
Diagnosis data No.449 indicates spindle angle from the one-rotation signal when bit 1 (SPP) of
parameter No.3117 is set to 1. Spindle angle displays to three decimal places. To display
spindle angle, spindle orientation must be performed once. Unit of spindle angle data is as
follows.
Bit 0 (ORPUNT) of parameter No.4542
Unit of data [deg]
0
0.088
1
0.011
NOTE
Once spindle orientation performed after power-on, position data can be read. To read
position data, set bit 1 (SPP) of parameter No.3117 to 1. (Except when maintenance is
performed, bit 1 (SPP) of parameter No.3117 must be set to 0.)
Diagnosis data related to rigid tapping
DGN 450
Spindle position error during rigid tapping
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 451
Spindle distribution during rigid tapping
560
B-64805EN/03
Diagnosis list
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 452
Difference in error amount between spindle and tapping axis during rigid tapping
(momentary value)
[Data type]
[Unit of data]
2-word spindle
%
DGN 453
Difference in error amount between spindle and tapping axis during rigid tapping
(maximum value)
[Data type]
[Unit of data]
2-word spindle
%
DGN 454
Accumulated spindle distribution during rigid tapping (cumulative value)
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 455
Difference in spindle-converted move command during rigid tapping (momentary value)
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 456
Difference in spindle-converted positional deviation during rigid tapping (momentary
value)
[Data type]
[Unit of data]
Word spindle
Detection unit
DGN 457
Width of synchronization error during rigid tapping (maximum value)
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 458
Tapping axis distribution amount during rigid tapping (cumulative value)
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 459
Selected spindle number during rigid tapping
[Data type]
2-word path
DGN 460
Difference in spindle-converted move command during rigid tapping (maximum value)
[Data type]
2-word spindle
561
Diagnosis list
B-64805EN/03
[Unit of data]
Detection unit
DGN 461
Difference in spindle-converted machine position during rigid tapping (momentary
value)
[Data type]
[Unit of data]
2-word spindle
Detection unit
DGN 462
Difference in spindle-converted machine position during rigid tapping (maximum value)
[Data type]
[Unit of data]
2-word spindle
Detection unit
Diagnosis data related to polygon machining with two spindles
DGN 470 #0
SPL
[Data type]
Bit path
Polygon synchronization with two spindles under way
DGN 470 #1
PSU
[Data type]
Bit path
Polygon synchronization mode with two spindles
being activated
NOTE
If only PSU becomes 1, but no change occurs, and the program stops in a block containing
a G51.2 command, the speed of an spindle does not reach the targeted polygon
synchronization speed, for example, because bit 7 (PST) of parameter No. 7603 = 0 keeps
the spindle from being energized.
DGN 470 #2
PEN
[Data type]
Bit path
Polygon synchronization mode with two spindles
DGN 470 #3
PSC
[Data type]
Bit path
Spindle speed being changed
DGN 470 #4
SCF
[Data type]
Bit path
Spindle speed changed
DGN 470 #6
562
LGE
released
during polygon synchronization mode with two spindles
during polygon synchronization mode with two spindles
B-64805EN/03
[Data type]
Diagnosis list
Bit path
The loop gain is different between the spindles during polygon synchronization mode
spindles.
with two
NOTE
When the speed is changed during polygon synchronization mode, LGE is set to 1 if the
spindle synchronous control loop gain used by the serial spindle control software is different
between the master spindle and polygon synchronization axis. Diagnosis display indicates
the loop gain because this function requires that both spindles be controlled with the same
loop gain. However, no alarm is issued even if the loop gain is different between the
spindles. For the spindle control software, the loop gain parameters used are changed
according to the state of the CTH1 and CTH2 gear signals.
DGN 470 #7
SC0
[Data type]
Bit path
Actual speed command is 0 during polygon synchronization mode
with two spindles.
NOTE
SC0 is not a programmed S command value. SC0 becomes "1" in the following cases.
When the command value becomes 0 as a result of the involvement of signals related
to spindle control (*SSTP, SOV0-SOV7)
or multi spindle control in the S command value
When the resolution is below the spindle control resolution (the result of
multiplying the command value by 4095/max spindle speed is less than 1)
When commanding from SIND control and the command output is 0
In the case of SC0/1, the spindle speed becomes 0, so the diagnostic data SCU
(No.471#0) also becomes "1". In this case, the polygon synchronous rotation ratio does
not hold, but it is treated as a result of the command and does not cause an alarm
(PS5018).
If the following status is indicated during the polygon synchronization mode, there are no
abnormalities.
Symbol
SC0
LGE
SCF
PSC
PEN
PSU
SPL
Data
0
0
1
-
0
0
1
Indication of the cause of polygon machining with two spindles alarms (PS5018, PS0314, PS0218)
#0 to #3 →
Causes for alarm PS5018
Alarm PS5018 is cleared by a reset, but the indication of its causes remains until the causes are cleared or the polygon
synchronization mode is released.
DGN 471 #0
SCU
[Data type]
Bit path
During inter-spindle polygon synchronization, the command speed is too small (when the unit
speed in the internal calculation turns to 0).
NOTE
SCU is also set to "1" when the spindle command speed is 0 (diagnostic data SC0 (470#7)
= 1), but the alarm (PS5018) "POLYGON SPINDLE SPEED ERROR" is not displayed in this
case because the command is a result of 0.
The alarm PS5018 "POLYGON SPINDLE SPEED ERROR" is displayed when diagnostic
display SC0 (470#7) = 0 and diagnostic display SCU (471#0) = 1.
Normally this does not occur with speed at which the spindle can rotate.
563
Diagnosis list
B-64805EN/03
DGN 471 #2
QCL
[Data type]
Bit path
The polygon synchronization axis is clamped.
NOTE
QCL becomes 1, when the polygon synchronization axis receives a command with a
polygon synchronization speed that is higher than the value specified in parameter No. 7621
and is clamped at that speed.
DGN 471 #3
SUO
[Data type]
Bit path
The specified speed is too high during polygon synchronization mode with two spindles. (It is
clamped to the upper limit calculated internally.)
NOTE
SUO occurs, if a result of (speed specified for the master spindle)/(value specified at P) is
higher than 59998. In other words, the master spindle must rotate at a speed lower than
59998 min-1 assuming P = 1.
#4
→ Causes for alarm PS0314
When alarm PS0314 occurs, the polygon synchronization mode is released, but the indication of its causes remains
until the alarm PS0314 is cleared by a reset.
DGN 471 #4
NSP
[Data type]
Bit path
A spindle necessary for control is not connected. (For example, there is not a serial spindle or
the second spindle.)
An axis was specified invalidly in polygon turning.
#5 to #7
→ Causes for alarm PS0218
When alarm PS0218 occurs, the polygon synchronization mode is released, but the indication of its causes remains
until the alarm PS0218 is cleared by a reset.
DGN 471 #5
QMS
[Data type]
Bit path
When bit 1 (QDR) of parameter No. 7603 = 1, a negative value is specified at Q.
DGN 471
#6
[Data type]
PQE
Bit path
In a G51.2, either P or Q has a value out of the specifiable range.
Or, P and Q are not specified as a pair.
DGN 471 #7
564
NPQ
B-64805EN/03
[Data type]
Diagnosis list
Bit path
In a G51.2, R is specified when P and Q have not been specified at all,
or none of P, Q, and R has been specified.
DGN 474
Rotation ratio for the master axis during the polygon synchronization mode with two
spindles (P command value)
[Data type]
2-word path
This indication is the current rotation ratio (P command value) of the master axis during the
polygon synchronization mode with two spindles.
DGN 475
Rotation ratio for the polygon synchronization axis during the polygon synchronization
mode with two spindles (Q command value)
[Data type] C
2-word path
This indication is the current rotation ratio (Q command value) of the polygon synchronization
axis during the polygon synchronization mode with two spindles.
DGN 476
Phase value of both spindles during polygon synchronous control between two
spindles (R command value)
[Data type]
2-word path
Displays the current phase value (R command value) during polygon synchronization mode
with two spindles. (Unit is the increment system of the reference axis)
However, when bit 5 (RDG) of parameter No. 7603 = 1, the serial spindle command shift
amount (command pulse count after calculating 360 degree = 4096 pulses) is displayed.
DGN 477
Number of actual rotation for the master axis during polygon synchronization mode with
two spindles (min-1)
[Data type]
2-word path
Displays the number of actual rotation for the master axis during polygon synchronization mode
with two spindles.
DGN 478
Number of rotation of the tool rotation axis during polygon machining, or the number
of actual rotation for the polygon synchronization axis during polygon synchronization
mode with two spindles (min-1)
[Data type]
2-word path
Displays the number of rotation of the tool rotation axis during polygon machining or the
number of actual rotation for the polygon synchronization axis during polygon synchronization
mode with two spindles.
Diagnosis data related to the small-hole peck drilling cycle
DGN 520
Total number of times a retraction operation has been performed during drilling since
G83 was specified
565
Diagnosis list
B-64805EN/03
DNG 521
Total number of times a retraction operation has been performed in response to the
reception of the overload torque detection signal during drilling since G83 was
specified.
[Data type]
Word path
NOTE
The total numbers of times output in Nos.520 and 521 are cleared to zero by a G83
command issued after the small-hole peck drilling cycle mode is entered.
DGN 522
Coordinate value of the drilling axis at which retraction operation starts (least input
increment)
DNG 523
Difference between the coordinate value of the drilling axis at which the previous
retraction operation started and the coordinate value of the drilling axis at which the
current retraction operation starts (least input increment: previous value minus current
value)
[Data type]
Real path
Diagnosis data related to the dual position feedback function
DGN 550
Full-closed loop error
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
-99999999 to +99999999
DGN 551
Semi-closed loop error
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
DGN 552
Error between semi-closed and closed loops
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
DGN 553
Amount of dual position compensation
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
-99999999 to +99999999
-99999999 to +99999999
-32768 to +32767
The data items displayed on the diagnosis screen are obtained at the following positions:
566
B-64805EN/03
Diagnosis list
Automatic alteration of tool position compensation
DGN 560
Manual tool compensation state number
[Data type]
[Unit of data]
[Valid data range]
Byte path
None
0 to 255
When incomplete operation was performed in manual tool compensation, one of the following
numbers is used for notification.
0:
Manual tool compensation was completed normally.
1:
The data of T code command falls outside the allowable range.
2:
The offset value falls outside the range.
3:
The offset number falls outside the range.
4:
Automatic operation or axis movement is being performed in the CNC.
5:
The CNC is in the tool-nose radius compensation mode.
6:
The CNC is in a mode other than the JOG mode, HNDL (INC) mode, and REF
mode.
7:
A CNC parameter is illegal.
8:
The CNC is in the 3-dimensional cutter compensation mode or tool center point
control mode.
DGN 656 #0
VRDY1 (Slave 1)
DGN 656 #1
VRDY1 (Slave 2)
DGN 656 #2
VRDY1 (Slave 3)
DGN 656 #3
VRDY1 (Slave 4)
[Data type]
Bit axis
Displays the ready state when VRDY OFF is issued for each amplifier of slave 1 to 4.
0:
Not-ready state
567
Diagnosis list
B-64805EN/03
1:
Ready state (amplifier ready state)
You can check the bits of diagnosis No. 656 to determine the amplifier which causes the VRDY
OFF alarm.
Data for adjusting the thread start position compensation in changing spindle speed
DGN 670
Delay in acceleration/deceleration after interpolation that is calculated in the NC
DGN 671
Servo delay calculated in the NC
DGN 672
Delay in one-rotation signal detection that is calculated in the NC
[Data type]
[Unit of data]
2-word path
Metric input: 0.00001 mm
Inch input : 0.000001 inch
0 to 99,999,999
[Valid data range]
Compensation amounts calculated by the NC are indicated. Use them to set adjustment
parameters Nos. 1446 to 1449.
State of high-speed HRV current control
The state of high-speed HRV current control is displayed.
DGN 700 #0
HON
[Data type]
Bit axis
The motor is controlled in the high-speed HRV current control mode.
DGN 700 #1
HOK
[Data type]
Bit axis
This bit is set to 1 when high-speed HRV current control is enabled.
High-speed HRV current control is enabled when the following conditions are satisfied:
Parameter (No.40164) is 0 or 3
Parameter (No.40164) is 4
Servo software, servo modules, and servo amplifiers suitable for high-speed HRV current
control are used.
When a separate detector interface unit is used, the separate detector interface unit is
suitable for high-speed HRV current control.
DGN 700 #2
DCLNK
[Data type]
Bit axis
This bit is set to 1 when voltage information can be output to the diagnosis screen.
DGN 700 #3
PSFMB
[Data type]
Bit axis
A high-resolution rotor scale (such as RCN727) is connected to the semi-closed side
568
B-64805EN/03
Diagnosis list
DGN 700 #4
FSFMB
[Data type]
Bit axis
A high-resolution rotor scale (such as RCN727) is connected to the full-closed side
DGN 700 #5
1VPP
[Data type]
Bit axis
Detector is connected via analog SDU
DGN 700 #6
O2048
[Data type]
Bit axis
The 2048 magnification interpolation circuit setting is enabled for the detector on the full-closed
side
DGN 700 #7
L2048
[Data type]
Bit axis
The 2048 magnification interpolation circuit setting is enabled for the detector on the semiclosed side (linear motor)
DGN 701 #0
RPF
[Data type]
Bit axis
In the rapid traverse command, the speed command by ",F" is:
0: Disabled.
1: Enabled.
Thermal growth compensation along tool vector
DGN 705
Thermal growth compensation amount for each axis
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
-32768 to +32767
The compensation amount for each axis in thermal growth compensation along the tool vector
is indicated.
Spindle error and warning states
DGN 710
Spindle error state
[Data type]
Byte spindle
When an error (yellow LED lighting + error number indicated) or warning occurs in a spindle
amplifier (SP), the number is displayed on the diagnosis screen.
569
Diagnosis list
B-64805EN/03
If neither error nor warning occurs, 0 is indicated.
For spindle errors, refer to ”FANUC AC SERVO MOTOR αi series, FANUC AC SPINDLE
MOTOR αi series, FANUC SERVO AMPLIFIER αi series MAINTENANCE MANUAL”.
For warnings, see "Spindle Warning Interface".
DGN 712
Warning status of spindle
[Data type]
Word spindle
When an error (yellow LED lighting + error number indicated) or warning occurs in a spindle
amplifier (SP), the number is displayed on the diagnosis screen.
If neither error nor warning occurs, 0 is indicated.
For spindle errors, refer to ”FANUC AC SERVO MOTOR αi series, FANUC AC SPINDLE
MOTOR αi series, FANUC SERVO AMPLIFIER αi series MAINTENANCE MANUAL”.
For warnings, see "Spindle Warning Interface".
DGN 720
Amplitude and offset information of phase A/B of the motor sensor (JYA2 connection)
[Data type]
2-word spindle
Thousands: The motor sensor (JYA2 connection) is indicated. Value of 1: motor sensor
Hundreds: The amplitude value is indicated as level 1 to 9. The standard value is 3 to 7.
Tens: The offset value of phase A is indicated as level 1 to 9. The standard value is 3 to 7.
Ones: The offset value of phase B is indicated as level 1 to 9. The standard value is 3 to 7.
NOTE
Other information is displayed when parameter No. 4532 is not 15.
Please check the rotating state on the above diagnosis screen display. (10 to 100min -1)
NOTE
The above “standard values” are criterion values based on the specifications of FANUC
analog sensors. The amplitude and offset levels are displayed also when an analog
sensor from another company is connected. In this case, however, the displayed levels
cannot be used for checking purposes because the standard values of analog sensors
from another company are unknown.
When analog sensors from another company are used, directly observe waveforms
using an oscilloscope or the SERVO GUIDE, and then check whether the
specifications of each analog sensor are satisfied.
DGN 722
Amplitude and offset information of phase A/B of the spindle sensor (JYA4 connection)
[Data type]
2-word spindle
Thousands: The spindle sensor (JYA4 connection) is indicated. Value of 2: spindle sensor
Hundreds: The amplitude value is indicated as level 1 to 9. The standard value is 3 to 7.
Tens: The offset value of phase A is indicated as level 1 to 9. The standard value is 3 to 7.
Ones: The offset value of phase B is indicated as level 1 to 9. The standard value is 3 to 7.
570
B-64805EN/03
Diagnosis list
NOTE
Other information is displayed when parameter No. 4532 is not 15.
Please check the rotating state on the above diagnosis screen display. (10 to 100min -1)
NOTE
The above “standard values” are criterion values based on the specifications of FANUC
analog sensors. The amplitude and offset levels are displayed also when an analog
sensor from another company is connected. In this case, however, the displayed levels
cannot be used for checking purposes because the standard values of analog sensors
from another company are unknown.
When analog sensors from another company are used, directly observe waveforms
using an oscilloscope or the SERVO GUIDE, and then check whether the
specifications of each analog sensor are satisfied.
OVC level
DGN 750
OVC level
[Data type]
[Unit of data]
2-word axis
%
The proportion of soft thermal (OVC) in the alarm issuance level is indicated.
Linear inclination compensation function
DGN 751
Each axis linear inclination compensation
[Data type]
[Unit of data]
[Valid data range]
2-word axis
Detection unit
-32768 to +32767
Compensation of linear inclination compensation for each axis is indicated.
DC link voltage information
DGN 752
DC link voltage information
[Data type]
[Unit of data]
[Valid data range]
Word axis
V
0 to 1023
DC link voltage information is indicated.
Diagnosis data related to servo motors
DGN 760
R phase current value
[Data type]
[Unit of data]
[Valid data range]
Word axis
“6554” shows maximum current of amplifier
-6554 to +6554
571
Diagnosis list
B-64805EN/03
The actual R phase current value of the servo motor is indicated.
DGN 761
Effective current value
[Data type]
[Unit of data]
[Valid data range]
Word axis
“8027” shows maximum current of amplifier
-8027 to +8027
The effective current value of the servo motor is indicated.
DGN 762
Activating phase
[Data type]
[Unit of data]
[Valid data range]
Word axis
256 is equal to 360 degrees
0 to 255
The activating phase (electrical angle) of the servo motor is indicated.
DGN 765
Code indicating sequence execution status and errors in automatic gain/filter
adjustment
[Data type]
Word axis
Negative value: Oscillation judgment was made on the control system during automatic
sequencing.
10,000ths: Normative model order (1 or 2)
1,000ths: Sequence phase (0,1,2,3,4,5), auto-tuning completed (8,9)
10 hundredths: 1st resonance frequency detected [Hz] (when sequence phase is 0, 1, or 2),
velocity gain value being tuned [%] (when sequence phase is 3, 4, or 5)
* If the sequence is unintentionally interrupted, check this diagnosis data.
NOTE
This diagnosis data is not visible when auto-tuning is activated on the dedicated screen. The tuning sequence is forcibly
interrupted when transitioning from the dedicated screen to another screen. To view this diagnosis data, start autotuning from the servo gain auto-tuning start signals SGTREQ1 to SGTREQ8 <Gn725>.
DGN 769
Measured backlash value
[Data type]
[Unit of data]
[Valid data range]
Word axis
Detection unit
0 to 32767
If you want to only diagnose and display the measured backlash value without performing
smart backlash compensation (full-closed), set parameter No. 2619 to 0.
Measurement of the backlash amount starts after you turn on the CNC and the motor
moves in both the positive and negative directions. The diagnosis screen displays 0 until
the measurement starts.
The backlash amount is calculated from the positions of the moving motor and the
separate detector.
DGN 770
572
Maximum possible machining time
B-64805EN/03
[Data type]
[Unit of data]
[Data range]
Diagnosis list
Word axis
s
0 to 1800
Diagnosis 770 displays the estimated time remaining until an OVC (software thermal) or OH
(overheat) alarm is issued at the current output. For 1800 seconds or greater, “1800 seconds”
is displayed.
In a configuration that uses a thermostat without temperature information, the remaining time
for OH alarm is not calculated.
Note: Configurations that use a thermostat without temperature information are as follows.
βiSc series servo motor
Linear motor to which a thermistor for temperature indication is not connected, or
synchronous built-in servo motor
DGN 772
Battery voltage for absolute pulsecoder
[Data type]
[Unit of data]
[Data range]
Word axis
10mV
0 to 1275
Displays the battery voltage value.
The display value is updated periodically while communication is taking place between the
servo amplifier and the pulsecoder.
DGN 800
Motor detector internal information 1
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 801
Motor detector internal information 2
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 801
Motor detector internal information 3
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 803
Motor detector internal information 4
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 804
Separate Detector I/F unit internal information 1
573
Diagnosis list
[Data type]
B-64805EN/03
2-word axis
The intelligent data of the separate detector is displayed.
DGN 805
Separate Detector I/F unit internal information 2
[Data type]
2-word axis
The intelligent data of the separate detector is displayed.
DGN 806
Separate Detector I/F unit internal information 3
[Data type]
2-word axis
The intelligent data of the separate detector is displayed.
DGN 807
Separate Detector I/F unit internal information 4
[Data type]
2-word axis
The intelligent data of the separate detector is displayed.
DGN 808
Motor detector internal information 5
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 809
Motor detector internal information 6
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 810
Motor detector internal information 7
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 811
Motor detector internal information 8
[Data type]
2-word axis
The intelligent data of the motor detector is displayed.
DGN 812
574
Separate Detector I/F unit internal information 5
B-64805EN/03
[Data type]
Diagnosis list
2-word axis
The intelligent data of the separate detector is displayed.
DGN 813
Separate Detector I/F unit internal information 6
[Data type]
2-word axis
The intelligent data of the separate detector is displayed.
DGN 814
Separate Detector I/F unit internal information 7
[Data type]
2-word axis
The intelligent data of the separate detector is displayed.
DGN 815
Separate Detector I/F unit internal information 8
[Data type]
2-word axis
The intelligent data of the separate detector is displayed.
DGN 891 #7
PPC
[Data type]
Bit axis
Current control mode is:
0:
not pressure and position control mode.
1:
pressure and position control mode.
Fan rotation speed
DGN 1002
FAN1 rotation speed
DGN 1003
FAN2 rotation speed
[Data type]
[Unit of data]
2-word
1/min
FAN1,FAN2: The rotation speed of the fans in the CNC unit are indicated.
If there is no applicable fan, 0 is indicated.
Reason why a start cannot be performed
The reason why a start cannot be performed is displayed.
DGN 1005 #0
JMD
[Data type]
Bit path
M,S,T,B of manual numeric command is specified while M,S,T,B is being executed.
575
Diagnosis list
B-64805EN/03
DGN 1005 #2
OHT
[Data type]
Bit path
Automatic operation can not start. (During a retract operation etc.)
DGN 1006 #0
*SP
[Data type]
Bit path
The feed hold signal (*SP) is 0.
DGN 1006 #1
ALM
[Data type]
Bit path
An alarm is being generated.
DGN 1006 #2
SRN
[Data type]
Bit path
The program restart signal (SRN) is “1”.
DGN 1006 #4
NOP
[Data type]
Bit path
The device is not ready in the DNC operation mode (RMT).
DGN 1006 #6
PTR
[Data type]
Bit path
The tool retraction signal (TRESC) is “1”.
Alternatively, the tool is not returned to the position where the tool retraction signal was input.
DGN 1006 #7
RVS
[Data type]
Bit path
Reverse operation of the program cannot be performed.
Alarm classification
The alarm type is displayed.
DGN 1007 #0
PS
[Data type]
Bit path
576
B-64805EN/03
Diagnosis list
Alarms on program and operation
DGN 1007 #1
BG
[Data type]
Bit path
Alarms related to background editing
DGN 1007 #2
SR
[Data type]
Bit path
Communication alarms
DGN 1007 #3
MC
[Data type]
Bit path
Macro alarms
DGN 1007 #4
EX
[Data type]
Bit path
External alarms
DGN 1007 #5
SW
[Data type]
Bit path
Parameter writing alarms
DGN 1007 #6
SV
[Data type]
Bit path
Servo alarms
DGN 1007 #7
OT
[Data type]
Bit path
Overtravel alarms
The alarm type is displayed.
DGN 1008 #0
PMC
577
Diagnosis list
[Data type]
B-64805EN/03
Bit path
PMC alarms
DGN 1008 #1
IO
[Data type]
Bit path
Memory file alarms
DGN 1008 #2
PW
[Data type]
Bit path
Alarms requiring power to be turned off
DGN 1008 #5
SP
[Data type]
Bit path
Spindle alarms
DGN 1008 #6
OH
[Data type]
Bit path
Overheat alarms
DGN 1008 #7
DS
[Data type]
Bit path
Ohter alarms
The alarm type is displayed.
DGN 1009 #0
IE
[Data type]
Bit path
Alarms related to wrong operation prevention
DGN 1009 #1
IOL
[Data type]
Bit path
Alarms related to I/O Link
DGN 1009 #6
578
WNG
B-64805EN/03
[Data type]
Diagnosis list
Bit path
Warning
DGN 1009 #7
OP
[Data type]
Bit path
Operator message
The cause of the operation is locked.
DGN 1013 #5
CHP
[Data type]
Bit path
Waiting the acc/dec completion of chopping.
DGN 1013 #7
SMZ
[Data type]
Bit path
Waiting the acc/dec completion.
Reset / feed hold state
The reset / feed hold state is displayed.
DGN 1010 #0
ESP
[Data type]
Bit path
During emergency stop.
DGN 1010 #1
RRW
[Data type]
Bit path
The reset and rewind signal is “1”.
DGN 1010 #2
ERS
[Data type]
Bit path
The external reset signal is “1”.
DGN 1010 #3
RST
[Data type]
Bit path
579
Diagnosis list
B-64805EN/03
The reset key is being pressed.
Cause of turning off of the cycle start lamp
The cause of turning off of the cycle start lamp is displayed.
DGN 1011 #0
ESP
[Data type]
Bit path
During emergency stop.
DGN 1011 #1
RRW
[Data type]
Bit path
The reset and rewind signal is “1”.
DGN 1011 #2
ERS
[Data type]
Bit path
The external reset signal is “1”.
DGN 1011 #3
RST
[Data type]
Bit path
The reset key is being pressed.
DGN 1011 #4
ALM
[Data type]
Bit path
An alarm is being generated.
DGN 1011 #5
MOD
[Data type]
Bit path
The mode has been changed to another mode.
DGN 1011 #6
STP
[Data type]
Bit path
Single-block stop.
DGN 1011 #7
580
HLD
B-64805EN/03
[Data type]
Diagnosis list
Bit path
During feed hold.
Cause of Lock
The cause of the operation is locked.
DGN 1014 #2
PST
[Data type]
Bit path
Motion lock by parameter rewriting.
DGN 1014 #3
CS2
[Data type]
Bit path
Motion lock by threading, rigid tapping, spindle positioning, and EGB.
DGN 1014 #4
CIR
[Data type]
Bit path
The feedrate calculated by the deceleration function based on acceleration in circular
interpolation is 0.
DGN 1014 #5
EDC
[Data type]
Bit path
The feedrate calculated by cutting feed instruction is almost 0. (when external deceleration is
effective)
DGN 1014 #6
POL
[Data type]
Bit path
The feedrate of one or less was calculated by polar coordinate interpolation.
DGN 1014 #7
FED
[Data type]
Bit path
The feedrate calculated by cutting feed instruction is almost 0. (override etc.)
The cause of the operation is locked.
DGN 1015 #0
BCT
[Data type]
Bit path
581
Diagnosis list
B-64805EN/03
Waiting for balance cutting.
The cause of the operation is locked.
DGN 1015 #3
OSE
[Data type]
Bit path
Because the positional deviation at start of Servo Learning Oscillation is larger than the
allowable positional deviation, oscillation cutting is not started.
Automatic data backup
The execution state of backup is indicated.
DGN 1016 #0
AEX
[Data type]
Bit
Automatic data backup is being performed.
DGN 1016 #1
DT1
[Data type]
Bit
Data 1 was updated in the previous backup.
DGN 1016 #2
DT2
[Data type]
Bit
Data 2 was updated in the previous backup.
DGN 1016 #3
DT3
[Data type]
Bit
Data 3 was updated in the previous backup.
DGN 1016 #6
ACM
[Data type]
Bit
Automatic data backup was performed.
DGN 1016 #7
ANG
[Data type]
Bit
An error occurred in automatic data backup.
582
B-64805EN/03
Diagnosis list
Custom macro / execution macro / auxiliary macro
DGN 1493
Number of blocks in the macro statements executed by a custom macro/execution
macro
[Data type]
[Unit of data]
Word path
Block
Displays the number of blocks in the macro statements executed by a custom macro/execution
macro per 1024 ms.
It provides an indication of the actual processing speed of macro statements.
DGN 1494
Number of blocks in executed by an auxiliary macro
[Data type]
[Unit of data]
Word path
Block
Displays the number of blocks executed by an auxiliary macro per 1024 ms.
It provides an indication of the actual processing speed of auxiliary macros.
CNC fan
DGN 1495 #1
FAN
[Data type]
Bit
Fan 2 does not work
DGN 1495 #2
NI1
DGN 1495 #3
NI2
[Data type]
Bit
Exchange information for CNC fan 2
#3
DGN 1495 #5
FAN
[Data type]
Bit
#2
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (The fan binds and starting-time is long.)
1
1
Exchange 1 and 2
Fan 1 does not work
DGN 1495 #6
NI1
DGN 1495 #7
NI2
583
Diagnosis list
[Data type]
B-64805EN/03
Bit
Exchange information for CNC fan 1
#7
#6
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (The fan binds and starting-time is long.)
1
1
Exchange 1 and 2
DGN 1496 #1
FAN
[Data type]
Bit
State
Fan 4 does not work
DGN 1496 #2
NI1
DGN 1496 #3
NI2
[Data type]
Bit
Exchange information for CNC fan 4
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
DGN 1496 #5
FAN
[Data type]
Bit
State
Fan 3 does not work
DGN 1496 #6
NI1
DGN 1496 #7
NI2
[Data type]
Bit
Exchange information for CNC fan 3
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
Main program
DGN 1497
584
Main program change counter
B-64805EN/03
[Data type]
[Unit of data]
[Data range]
Diagnosis list
Byte path
1 time
0 to 255
This number counts change of main program from power on.
If this counter exceeds 255, it returns to 0 and is incremented again.
The counter turns to 0 when power is off.
DGN 1498
Remaining number of variable names that can be set
[Data type]
[Unit of data]
[Valid data range]
Word path
1 name
0 to maximum number of variable names
The number of remaining variable names that can be set by the SETVN and DEFREAL
commands.
Related to the Spindles
DGN 1520
Spindle total revolution number 1
DGN 1521
Spindle total revolution number 2
[Data type]
[Unit of data]
[Valid data range]
2-word spindle
1000 rotations
0 to 999999999
The number of revolutions of the spindle is counted and the total number of revolutions is
indicated.
DGN 1544
Spindle positioning sequence state
[Data type]
2-word spindle
Displays the spindle positioning sequence state. (For each spindle)
1. Spindle positioning switch sequence
Display
00010003
00010005
00010006
00010008
00010009
0001000A
Description
Waiting the spindle stop completion signal SPSTPs to be
turned ON (changed from 0 to 1)
Waiting the completion of switching to spindle positioning
mode
Waiting the spindle unclamp completion signal *SUCPFs to
be turned ON (changed from 0 to 1)
Waiting the completion of orientation
Waiting the preset processing completion after orientation
Waiting the spindle clamp completion signal *SCPFs to be
turned ON (changed from 0 to 1)
2. Spindle positioning sequence
Display
00020004
00020006
Description
Waiting SPSTPs to be turned ON (changed from 0 to 1)
Waiting *SUCPFs to be turned ON (changed from 1 to 0)
Waiting the completion of positioning
585
Diagnosis list
B-64805EN/03
00020007
Waiting *SCPFs to be turned ON (changed from 1 to 0)
In case of spindle positioning sequence B specification (parameter IMB (No. 4950#7) =
1):
Display
00040003
00040005
00040006
00040008
00040009
0004000A
Description
Waiting SPSTPs to be turned ON (changed from 0 to 1)
Waiting the completion of switching to spindle positioning
mode
Waiting *SUCPFs to be turned ON (changed from 1 to 0)
Waiting the completion of positioning
Waiting *SCPFs to be turned ON (changed from 1 to 0)
Waiting the completion of cancelling spindle positioning mode
3. Spindle positioning mode cancel sequence
Display
00030003
00030004
Description
Waiting SPSTPs to be turned ON (changed from 0 to 1)
Waiting *SUCPFs to be turned ON (changed from 1 to 0)
Waiting the completion of cancelling spindle positioning mode
DGN 1547
Spindle motor feedrate (2-word)
[Data type]
[Unit of data]
2-word spindle
min-1
DGN 1570 #0
S2W
[Data type]
Bit spindle
The spindle velocity resolution is a maximum spindle speed / 1048575[min -1].
DGN 1570 #7
LNK
[Data type]
Bit spindle
Spindle I/F is
0:
Operating normally.
1:
The board is operating normally.
Diagnosis data related to spindle speed fluctuation detection
DGN 1590
The index number of the spindle axis that is subjected to spindle speed fluctuation
detection
[Data type]
2-word path
The index number of the spindle axis that is subjected to spindle speed fluctuation detection is
indicated.
DGN 1591
Allowable speed ratio used to assume that the spindle has reached a specified speed
[Data type]
[Unit of data]
Word path
1%/0.1%
586
B-64805EN/03
[Valid data range]
Diagnosis list
1 to 100/1 to 1000
When the spindle speed fluctuation detection function is used, allowable speed ratio used to
assume that the spindle has reached a specified speed is indicated.
NOTE
The unit of data is determined by bit 0 (FLR) of parameter No. 4900.
DGN 1592
Spindle speed fluctuation ratio for not issuing a spindle speed fluctuation detection
alarm
[Data type]
[Unit of data]
[Valid data range]
Word path
1%/0.1%
1 to 100/1 to 1000
When the spindle speed fluctuation detection function is used, spindle speed fluctuation ratio
for not issuing an alarm is indicated.
NOTE
The unit of data is determined by bit 0 (FLR) of parameter No. 4900.
DGN 1593
Spindle speed fluctuation width for not issuing a spindle speed fluctuation detection
alarm
[Data type]
[Unit of data]
[Valid data range]
2-word path
min-1
0 to 99999
When the spindle speed fluctuation detection function is used, allowable fluctuation width for
not issuing an alarm is indicated.
DGN 1594
Time from the change of a specified speed until spindle speed fluctuation detection is
started
[Data type]
[Unit of data]
[Valid data range]
2-word path
msec
0 to 999999
When the spindle speed fluctuation detection function is used, time from the change of a
specified speed until spindle speed fluctuation detection is started is indicated. Spindle speed
fluctuation detection is not performed until a set time has elapsed after a specified speed is
changed. When the actual spindle speed is assumed to have reached a specified value within
a set time (dp), spindle speed fluctuation detection is started.
NOTE
Diagnosis data Nos.1590 to 1594 are "0" when spindle speed fluctuation detection function
is disabled as follows.
In G25 mode (spindle speed fluctuation detection OFF)
There is no spindle selected to perform spindle speed fluctuation detection
The specified spindle speed is 0 min-1
A search by program restart is in progress
Spindle is under other than velocity control
587
Diagnosis list
B-64805EN/03
Communication between spindle amplifier and servo amplifier
DGN 1612
The index number of the spindle axis that synchronizes with each servo axis
[Data type]
Byte axis
The index number of the spindle axis that can use direct communication between a spindle
amplifier and a servo amplifier on FSSB connection is displayed.
Servo insulation deterioration detection function
DGN 1700 #0
ZUD
[Data type]
Bit axis
When Leakage Detection Function is effective the insulation resistance is
0:
Measurement completion
1:
Unmeasurement
DGN 1700 #1
ZND
[Data type]
Bit axis
Leakage Detection Function
0:
Correspondence
1:
Non-correspondence
DGN 1700 #2
ZMS
[Data type]
Bit axis
Insulation resistance
0:
Measurement incompleteness end
1:
Measurement completion (completion:0→1, Emergency stop:0)
DGN 1700 #3
INS
[Data type]
Bit axis
Insulation resistance decrease
0:
(More than standard value.) Default 10MΩ
1:
The insulation resistance is abnormal. (Below standard value)
DGN 1700 #4
ZTR
[Data type]
Bit axis
Insulation resistance measurement circuit communication abnormality
0:
Normal
1:
Communication abnormality
588
B-64805EN/03
Diagnosis list
DGN 1700 #5
ZOF
[Data type]
Bit axis
Insulation resistance measurement circuit offset is excessive
0:
Normal
1:
Offset is excessive
DGN 1700 #6
RLY
[Data type]
Bit axis
Between ground relay is abnormal.
0:
Normal
1:
Abnormal
DGN 1700 #7
VPG
[Data type]
Bit axis
The VPG offset is excessive.
0:
Normal
1:
Offset is excessive
DGN 1701
Insulation resistance data
[Data type]
[Unit of data]
[Valid data range]
Real axis
MΩ
0.0 to 102.1
Spindle insulation deterioration detection function
DGN 1702 #0
ZUD
[Data type]
Bit spindle
When Leakage Detection Function is effective the insulation resistance is
0:
Measurement completion
1:
Unmeasurement
DGN 1702 #1
ZND
[Data type]
Bit spindle
Leakage Detection Function
0:
Correspondence
1:
Non-correspondence
DGN 1702 #2
ZMS
589
Diagnosis list
[Data type]
B-64805EN/03
Bit spindle
Insulation resistance
0:
Measurement incompleteness end
1:
Measurement completion (completion:0→1, Emergency stop:0)
DGN 1702 #3
INS
[Data type]
Bit spindle
Insulation resistance decrease
0:
(More than standard value.) Default 10MΩ
1:
The insulation resistance is abnormal. (Below standard value)
DGN 1702 #4
ZTR
[Data type]
Bit spindle
Insulation resistance measurement circuit communication abnormality
0:
Normal
1:
Communication abnormality
DGN 1702 #5
ZOF
[Data type]
Bit spindle
Insulation resistance measurement circuit offset is excessive
0:
Normal
1:
Offset is excessive
DGN 1702 #6
RLY
[Data type]
Bit spindle
Between ground relay is abnormal.
0:
Normal
1:
Abnormal
DGN 1702 #7
VPG
[Data type]
Bit spindle
The VPG offset is excessive.
0:
Normal
1:
Offset is excessive
DGN 1703
Insulation resistance data
[Data type]
Real spindle
590
B-64805EN/03
[Unit of data]
[Valid data range]
Diagnosis list
MΩ
0.0 to 102.1
NOTE
Leakage Detection Function 1700 to 1703 is detected by the emergency stop on. And the
data detected by the emergency stop off is maintained.
Internal cooling fan for the servo amplifier
DGN 1710 #2
AI1
DGN 1710 #3
AI2
[Data type]
Bit axis
Exchange information for servo amplifier internal cooling fan 2
#3
#2
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1710 #5
FAN
[Data type]
Bit axis
Servo amplifier internal cooling fan 1 does not work
DGN 1710 #6
AI1
DGN 1710 #7
AI2
[Data type]
Bit axis
Exchange information for servo amplifier internal cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1711
Speed of internal cooling fan 1 for servo amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 1 for servo amplifier.
591
Diagnosis list
B-64805EN/03
DGN 1712
Speed of internal cooling fan 2 for servo amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 2 for servo amplifier.
Radiator cooling fan for servo amplifier
DGN 1713 #1
FAN
[Data type]
Bit axis
Servo radiator cooling fan 2 does not work
DGN 1713 #2
AR1
DGN 1713 #3
AR2
[Data type]
Bit axis
Exchange information for servo radiator cooling fan 2
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1713 #5
FAN
[Data type]
Bit axis
State
Servo radiator cooling fan 1 does not work
DGN 1713 #6
AR1
DGN 1713 #7
AR2
[Data type]
Bit axis
Exchange information for servo radiator cooling fan 1
592
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
B-64805EN/03
Diagnosis list
DGN 1714
Speed of radiator cooling fan 1 for servo amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 1 for servo amplifier.
DGN 1715
Speed of radiator cooling fan 2 for servo amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 2 for servo amplifier.
Internal cooling fan for common power supply
DGN 1716 #1
FAN
[Data type]
Bit axis
Common power supply internal cooling fan 2 does not work
DGN 1716 #2
PI1
DGN 1716 #3
PI2
[Data type]
Bit axis
Exchange information for Common power supply internal cooling fan 2
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1716 #5
FAN
[Data type]
Bit axis
State
Common power supply internal cooling fan 1 does not work
DGN 1716 #6
PI1
DGN 1716 #7
PI2
[Data type]
Bit axis
593
Diagnosis list
B-64805EN/03
Exchange information for Common power supply internal cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1717
Speed of internal cooling fan 1 for common power supply of servo motor
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 1 for common power supply of servo motor.
DGN 1718
Speed of internal cooling fan 2 for common power supply of servo motor
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 2 for common power supply of servo motor.
Radiator cooling fan for common power supply
DGN 1719 #1
FAN
[Data type]
Bit axis
Common power supply radiator cooling fan 2 does not work
DGN 1719 #2
PR1
DGN 1719 #3
PR2
[Data type]
Bit axis
Exchange information for Common power supply radiator cooling fan 2
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1719 #5
FAN
[Data type]
Bit axis
State
Common power supply radiator cooling fan 1 does not work
594
B-64805EN/03
Diagnosis list
DGN 1719 #6
PR1
DGN 1719 #7
PR2
[Data type]
Bit axis
Exchange information for Common power supply radiator cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1720
Speed of radiator cooling fan 1 for common power supply of servo motor
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 1 for common power supply of servo motor.
DGN 1721
Speed of radiator cooling fan 2 for common power supply of servo motor
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 2 for common power supply of servo motor.
Internal cooling fan for spindle amplifier
DGN 1722 #1
FAN
[Data type]
Bit spindle
Spindle internal cooling fan 2 does not work
DGN 1722 #2
AI1
DGN 1722 #3
AI2
[Data type]
Bit spindle
Exchange information for spindle internal cooling fan 2
#3
#2
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
595
Diagnosis list
B-64805EN/03
DGN 1722 #5
FAN
[Data type]
Bit axis
Spindle internal cooling fan 1 does not work
DGN 1722 #6
AI1
DGN 1722 #7
AI2
[Data type]
Bit spindle
Exchange information for spindle internal cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1723
Speed of internal cooling fan 1 for spindle amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 1 for spindle amplifier.
DGN 1724
Speed of internal cooling fan 2 for spindle amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 2 for spindle amplifier.
Radiator cooling fan for spindle amplifier
DGN 1725 #1
FAN
[Data type]
Bit spindle
Spindle radiator cooling fan 2 does not work
DGN 1725 #2
AR1
DGN 1725 #3
AR2
[Data type]
2-word
596
B-64805EN/03
[Unit of data]
Diagnosis list
1/min
Exchange information for spindle radiator cooling fan 2
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1725 #5
FAN
[Data type]
Bit spindle
State
Spindle radiator cooling fan 1 does not work
DGN 1725 #6
AR1
DGN 1725 #7
AR2
[Data type]
Bit spindle
Exchange information for spindle radiator cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1726
Speed of radiator cooling fan 1 for spindle amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 1 for spindle amplifier.
DGN 1727
Speed of radiator cooling fan 2 for spindle amplifier
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 2 for spindle amplifier.
Internal cooling fan for common power supply
DGN 1728 #1
FAN
[Data type]
Bit spindle
597
Diagnosis list
B-64805EN/03
Common power supply internal cooling fan 2 does not work
DGN 1728 #2
PI1
DGN 1728 #3
PI2
[Data type]
Bit spindle
Exchange information for Common power supply internal cooling fan 2
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1728 #5
FAN
[Data type]
Bit spindle
State
Common power supply internal cooling fan 1 does not work
DGN 1728 #6
PI1
DGN 1728 #7
PI2
[Data type]
Bit spindle
Exchange information for Common power supply internal cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1729
Speed of internal cooling fan 1 for common power supply of spindle motor
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of internal cooling fan 1 for common power supply of spindle motor.
DGN 1730
Speed of internal cooling fan 2 for common power supply of spindle motor
[Data type]
[Unit of data]
2-word
1/min
598
B-64805EN/03
Diagnosis list
Indicates the speed of internal cooling fan 2 for common power supply of spindle motor.
Radiator cooling fan for common power supply
DGN 1731 #1
FAN
[Data type]
Bit spindle
Common power supply radiator cooling fan 2 does not work
DGN 1731 #2
PR1
DGN 1731 #3
PR2
[Data type]
Bit spindle
Exchange information for Common power supply radiator cooling fan 2
#3
#2
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1731 #5
FAN
[Data type]
Bit spindle
State
Common power supply radiator cooling fan 1 does not work
DGN 1731 #6
PR1
DGN 1731 #7
PR2
[Data type]
Bit spindle
Exchange information for Common power supply radiator cooling fan 1
#7
#6
State
0
0
Normal
0
1
Exchange 1 (The fan speed decreases)
1
0
Exchange 2 (dirt on fan)
1
1
Running energy-saving mode
DGN 1732
Speed of radiator cooling fan 1 for common power supply of spindle motor
[Data type]
[Unit of data]
2-word
1/min
599
Diagnosis list
B-64805EN/03
Indicates the speed of radiator cooling fan 1 for common power supply of spindle motor.
DGN 1733
Speed of radiator cooling fan 2 for common power supply of spindle motor
[Data type]
[Unit of data]
2-word
1/min
Indicates the speed of radiator cooling fan 2 for common power supply of spindle motor.
DGN 1770 #0
SYS
[Data type]
Bit
The number of axes/spindles setting for the entire system is incorrect.
Refer to diagnostic data No. 1772.
DGN 1770 #1
PT1
[Data type]
Bit
The setting number of axes/spindle for path 1 (Note) is incorrect.
Refer to path 1 diagnostic data No. 1773.
Note: Paths 1 to 4 are assigned in the order of machining path 1, machining path 2, loader path
1, and loader path 2.
If there is a path that does not exist, the numbers 1-4 are assigned to only the paths that do
exist without skipping between them.
DGN 1770 #2
PT2
[Data type]
Bit
The setting number of axes/spindle for path 2 (Note) is incorrect.
Refer to path 2 diagnostic data No. 1773.
Note: Paths 1 to 4 are assigned in the order of machining path 1, machining path 2, loader path
1, and loader path 2.
If there is a path that does not exist, the numbers 1-4 are assigned to only the paths that do
exist without skipping between them.
DGN 1770 #3
PT3
[Data type]
Bit
The number of axes/spindle setting for path 3(Note) is incorrect.
Refer to path 3 diagnostic data No. 1773.
Note: Paths 1 to 4 are assigned in the order of machining path 1, machining path 2, loader path
1, and loader path 2.
If there is a path that does not exist, the numbers 1-4 are assigned to only the paths that do
exist without skipping between them.
DGN 1770 #4
600
PT4
B-64805EN/03
[Data type]
Diagnosis list
Bit
The setting number of axes/spindle for path 4 (Note) is incorrect.
Refer to path 4 diagnostic data No. 1773.
Note: Paths 1 to 4 are assigned in the order of machining path 1, machining path 2, loader path
1, and loader path 2.
If there is a path that does not exist, the numbers 1-4 are assigned to only the paths that do
exist without skipping between them.
DGN 1772 #0
AX0
[Data type]
Bit
The number of feed axes in the entire system is incorrect.
Check the diagnostic data AXS (bit 0 of parameter No.1774) for the current number of feed
axes.
DGN 1772 #1
SP0
[Data type]
Bit
The number of spindles in the entire system is incorrect. Check the diagnostic data SVS (bit 1
of parameter No.1774) and SPD (bit 1 of parameter No.1775) for the current spindle number.
DGN 1772 #2
TAX
[Data type]
Bit
The total number of controlled axes in the entire system is incorrect.
Check the diagnostic data TAS (bit 2 of parameter No.1774) and TAD (bit 2 of parameter
No.1775) for the current total number of control axes.
DGN 1772 #3
AX1
[Data type]
Bit
The number of controlled axes in the overall system setup is incorrect.
Check the setting of parameter No. 0987.
DGN 1772 #4
SP1
[Data type]
Bit
The number of controlled spindle axes in the overall system setup is incorrect.
Check the setting of parameter No. 0988.
DGN 1772 #5
CSV
[Data type]
Bit
The number of connected servo motors is incorrect.
601
Diagnosis list
B-64805EN/03
Check the diagnostic data CSS (No.1774#5) for the current number of connected servo
motors.
DGN 1772 #6
CVP
[Data type]
Bit
The maximum number of axes (number of connected servo motors + number of spindle
motors) is incorrect.
Check the current total number of connected servo motors (diagnostic data CSS (No.1774#5))
and the number of connected spindle motors (diagnostic data CSP (No.1775#1)).
DGN 1773 #0
AX0
[Data type]
Bit path
The number of feed axes per path is incorrect.
Check the diagnostic data AXS (bit 0 of parameter No.1774) for the current number of feed
axes.
DGN 1773 #1
SP0
[Data type]
Bit path
The number of spindles per path is incorrect.
Check the diagnostic data SVS (bit 1 of parameter No.1774) and SPD (bit 1 of parameter
No.1775) for the current spindle number.
DGN 1773 #2
TAX
[Data type]
Bit path
The total number of controlled axes per path is incorrect.
Check the diagnostic data TAS (bit 2 of parameter No.1774) and TAD (bit 2 of parameter
No.1775) for the current total number of control axes.
DGN 1773 #3
AX1
[Data type]
Bit path
The number of controlled axes in the setup for each path is incorrect.
Check the assignment of axes for each path with parameter No. 0981.
DGN 1773 #4
SP1
[Data type]
Bit path
The number of controlled spindles in the setup for each system is incorrect.
Check the spindle assignment for each path with parameter No. 0982.
602
B-64805EN/03
Diagnosis list
DGN 1774 #0
AXS
[Data type]
Bit axis
The servo axis has been counted in the number of feed axes.
The current number of feed axes can be obtained by counting the number of axes for which
this bit is 1.
DGN 1774 #1
SVS
[Data type]
Bit axis
The servo spindle has been counted in the number of spindles.
By counting the number of axes/spindles for which this bit and the diagnostic data SPD (No.
1775#1) is 1
, the current number of spindles can be obtained.
DGN 1774 #2
TAS
[Data type]
Bit axis
Servo axes have been counted in the total number of controlled axes.
By counting the number of axes/spindles for which this bit and the diagnostic data TAD (No.
1775#2) is 1
, the current total number of controlled axes can be obtained.
DGN 1774 #5
CSS
[Data type]
Bit axis
The servo axis has been counted in the number of connected servo motors.
By counting the number of axes where this bit is 1, the current number of connected servo
motors can be obtained.
DGN 1774 #7
ADA
[Data type]
Bit axis
The servo axis (No.1023≥49) assigned to the additional axis board is not (1), (2), or (3). Alarm
PW1203 "Servo axis assignment error (additional axis board)" has occurred.
(1) Axes belonging to the loader path
(2) Axis dedicated to PMC axis control (bit 0 (OPAx) of parameter No. 989 = 1)
(3) Spindle controlled by servo motor (bit 7 (SRVx) of parameter No. 11000 = 1)
DGN 1775 #1
SPD
[Data type]
Bit spindle
The serial spindle and analog spindles have been counted in the number of spindles.
The current number of spindles can be obtained by counting the number of axes/spindles for
which this bit and the diagnostic data SVS (No.
0