Structures 74 (2025) 108489 Contents lists available at ScienceDirect Structures journal homepage: www.elsevier.com/locate/structures Experimental and numerical investigations on progressive collapse resistance of planar reinforced concrete frames with different storeys Jian Yuan a, Kun Liu b,c , Shan Wang b,c , Liang Tan d, Shao-Bo Kang b,c,* a Academy of Combat Support, Rocket Force University of Engineering, Xi’an 710025, China Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China c School of Civil Engineering, Chongqing University, Chongqing 400045, China d China Nerin Engineering Co, Ltd., Nanchang 330031, China b A R T I C L E I N F O A B S T R A C T Keywords: Progressive collapse Reinforced concrete frames Vierendeel action Column flexural failure This study aims to investigate the effect of storey number on the progressive collapse resistance of reinforced concrete planar frames subjected to the removal of a penultimate column. To investigate the influence of storeys on the collapse resistance of frames, a single-storey frame and a double-storey frame were tested under a concentrated point load. The resistance, failure modes, and reinforcement strain development were obtained the test. Test results indicated that compressive arch action (CAA) and load capacities of the double-storey frame were approximately 0.9 and 1.0 times greater than those of the single-storey frame, respectively. Besides, in the double-storey frame, the first-storey beam experienced CAA and catenary action, while the second-storey beam was under axial compression due to the presence of Vierendeel action. A simplified method was developed to evaluate the Vierendeel action and load capacity of double-storey frames. Subsequently, a numerical model for multi-storey frames was established using Diana software to study Vierendeel action. Experimental results indicated that the contribution of Vierendeel action to the total load reduced as displacement increased. Frames with varying numbers of storeys exhibited different force transfer mechanisms, and the load capacities increased with increasing number of storeys. When the number of storeys of the plane frame increased from two to five, the CAA and load-bearing capacity increased by 144.8 % and 153.8 %, respectively. This study provided a basis for subsequent research on the progressive collapse resistance of multi-storey asymmetric planar frames. 1. Introduction Progressive collapse of structures is characterized by the local failure of critical components under accidental loads, causing the collapse of adjacent members, and resulting in the failure of a significantly larger portion of the structure. Such collapses are frequently triggered by accidents such as explosions and earthquakes [1], resulting in extensive casualties and significant economic losses. These incidents highlight the importance of investigating the progressive collapse resistance of structures. Numerous experimental studies on progressive collapse resistance have been performed, mainly focusing on four types of structures, namely, beam-column substructures [2–6], beam-slab substructures [7–9], planar frames [10–12], and spatial frames [13–15]. These studies identify three key mechanisms for resisting collapse, namely, flexural action (FA), compressive arch action (CAA) and catenary action [3,16, 17]. Su et al. [2] performed static collapse tests on twelve beam-column structures following the removal of the middle column and revealed that the CAA capacity increased with the reinforcement ratio and the beam span-to-height ratio. Kang et al. [3,4] carried out experimental tests on precast concrete beam-slab substructures, and found that considering axial forces in beams under CAA and catenary action significantly increased the resistance of beams to progressive collapse. Besides, suggestions were also provided for improving the resistance of precast concrete members. Gu et al. [9] investigated the influence of floor flange widths on T-beam substructures and revealed that floor flanges substantially improved the load capacity and promoted earlier mobilisation of catenary action. Stinger et al. [10] investigated the collapse resistance of a two-span, double-storey frame featuring either continuous or discontinuous longitudinal rebars, as well as partially filled walls. Experimental results showed that the continuous longitudinal rebars could significantly enhance the CAA capacity of the frame, whereas the * Corresponding author at: School of Civil Engineering, Chongqing University, Chongqing 400045, China. E-mail address: kang0119@cqu.edu.cn (S.-B. Kang). https://doi.org/10.1016/j.istruc.2025.108489 Received 11 October 2024; Received in revised form 25 December 2024; Accepted 15 February 2025 Available online 22 February 2025 2352-0124/© 2025 Institution of Structural Engineers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies. J. Yuan et al. Structures 74 (2025) 108489 effect on the catenary action capacity could be ignored. A four-span, three-storey concrete structure was studied for the progressive collapse resistance by Sagiroglu et al. [11], and it was found that Vierendeel action significantly increased its resistance to progressive collapse. Xiao et al. [13] conducted tests on a three-storey space frame with a removed column and found that the frame resisted collapse through catenary action in beams and yield-line mechanism in floors. A plastic hinge was observed to form at the end of the bottom column at failure. The studies indicated that for multi-storey frames, particularly when boundary restraints were weak, the force transfer mechanisms differed significantly from those in single-storey frames. In multi-storey frames, deflections of side columns caused Vierendeel action, which led to different axial force distributions in the beams at each storey and made it difficult to accurately assess the collapse resistance of the frame. Fabio et al. [18] conducted a comparative analysis of the seismic performance of a 10-storey reinforced concrete frame subjected to a sudden loss of central and corner columns and considered scenarios with and without the contribution of masonry-infilled walls. The results indicated that masonry infill walls interacted with the main structure during the sudden column loss, thereby enhancing the resistance and stiffness of the frame. Notably, the research on the collapse resistance of multi-storey frames was still limited. Currently, many design methods for frames to mitigate progressive collapse have been proposed. Both direct and indirect methods have been integrated into design standards [19,20] and guidelines [21,22]. Kang et al. [23] proposed a method to calculate the CAA capacity based on the equilibrium and deformation compatibility of beams. Long et al. [24] developed a simplified model to estimate the catenary action capacity by employing the moment capacity of column sections and the axial force-bending moment interaction diagram of beams. Izzuddin et al. [25] simplified a frame into basic beam elements based on the assumption that the force transfer paths in each storey were the same, and analysed each beam element separately. Then, the overall collapse resistance of the frame was calculated using linear combinations. However, this model was only suitable for frames with symmetric or strong boundary restraints, as it ignored inter-storey interactions within the frame. In addition, numerous finite element analyses have been conducted to quantify the progressive collapse resistance of frames. Feng et al. [26] employed a finite element model to systematically evaluate the effects of multi-span continuous beams and various column removal scenarios on reinforced concrete frame structures with and without slabs. The results showed that continuous span beams increased the internal compressive force within the beam during the CAA stage and significantly enhanced the resistance of the substructure. Fu et al. [27] demonstrated through numerical simulations that in multi-storey frames, CAA and catenary action occurred only in the first-storey beam, while the axial forces in the beams on other storeys were quite limited. Currently, there is no simplified method available for predicting the Vierendeel action capacity and collapse resistance of multi-storey frames characterized by weak boundary restraints. In this study, two reinforced concrete plane frames with a removed penultimate column were tested subjected to a quasi-static pushdown loading regime to explore their resistance, failure modes and reinforcement strain development. The effect of storey numbers on the resistance of frames was investigated. Subsequently, a simplified calculation method was proposed to predict the collapse resistance of double-storey frames. Besides, a numerical model was established for multi-storey frames using Diana software to study the mechanism of Vierendeel action and the relationship between the storey number and the load capacity of multi-storey frames. accordance with the Chinese standards [28–30]. Fig. 1 shows the dimensions of the prototype structure and the specimen locations. The height of the first storey was 4.2 m, but the height of the remaining storeys was 3.6 m. The centre-to-centre spacing between columns in two perpendicular directions was 6.6 m. The live and dead loads were designed as 2.5 kN/m² and 4.5 kN/m² per storey, respectively. The dimensions of beams were 300 mm × 600 mm, and the column dimensions were 600 mm square. In this experimental study, double-span planar frames in the prototype structure were extracted, as shown in Fig. 1. The scenario of column removal, a realistic condition in engineering applications, was considered on the first storey. To fit the physical constraints of the laboratory, 1/3 scaled models of the planar frames were used instead of the prototype frame. Two planar frames, named F-1 and F-2, were designed for testing. Table 1 provides the dimensions and reinforcement details of the two planar frames. In the designated notation, F represents the frame specimen, and the second numeral indicates the number of storeys of each specimen. Fig. 2 shows the dimensions and reinforcement details of the two frames. F-1 was designed as a single-storey, two-bay planar frame subjected to the removal of a penultimate column, as shown in Fig. 2(a). The beam had a clear span of 2000 mm, and the storey height was 1400 mm. To maintain the boundary conditions of the extracted frame, the beam was extended by one-fourth of its span beyond the right column. Besides, four bolts were embedded in the beam extension to connect it to the horizontal restraint. The cross-sectional dimensions of columns and beams were 200 mm × 200 mm and 100 mm × 200 mm, respectively. The beams were reinforced with two 12 mm diameter steel rebars at the top and two 10 mm diameter rebars at the bottom, and the overall reinforcement ratio was 1.22 %. The columns contained eight longitudinal steel rebars, each with a diameter of 8 mm. Transverse reinforcement, consisting of 6 mm diameter steel rebars, was placed at 100 mm spacings in the beams and columns. In F-2, the reinforcement ratios of beams and columns remained the same at the first and second storeys. However, the heights of the first and second storeys were different, with 1400 mm for the first storey and 1200 mm for the second storey, as shown in Fig. 2(b). To facilitate the installation of frames, the longitudinal reinforcement at the top of the columns was welded to steel plates with a thickness of 10 mm. 2.2. Material properties Deformed rebars HRB400 with diameters of 10 mm, 12 mm, and 14 mm were utilized for the longitudinal reinforcement in the beams and columns, and round rebars HPB300 of 6 mm diameter were utilized for the transverse reinforcement. The mechanical properties of the steel rebars were determined through uniaxial tension tests in accordance with GB/T 228–2010 [31], as shown in Fig. 3. Table 2 summarizes the tensile properties of steel rebars. The yield strength of stirrups was 367 MPa, and those of longitudinal reinforcement with diameters of 10 mm, 12 mm, and 14 mm were 461 MPa, 434 MPa, and 415 MPa, respectively. A series of uniaxial compression tests were conducted on cubic concrete samples with dimensions of 150 mm to measure the compressive strength of concrete. The compressive strengths of concrete for frames F-1 and F-2 were 47.2 MPa and 46.9 MPa, respectively. 2.3. Test setup and instrumentation The test setup for F-1 and F-2 consisted of the loading system, reaction frame and restraint systems, as shown in Fig. 4. To simulate a progressive collapse scenario, the top of the main column was loaded with a quasi-static force from a hydraulic jack with a load cell, and compression forces were also applied to side columns using hydraulic jacks. The hydraulic jacks were connected to the reaction frame using rollers to ensure that the applied compression remained vertical. To replicate the boundary conditions, the right beam extension was 2. Experimental programme 2.1. Test specimens A five-storey prototype reinforced concrete frame was designed in 2 J. Yuan et al. Structures 74 (2025) 108489 Fig. 1. Geometric dimensions of the prototype structure and the location of specimens. Table 1 Details of test frames. Specimen Beam Cross-section (mm) F− 1 F− 2 100 × 250 100 × 250 Column Reinforcement Top Bottom 2T12 2T12 2T10 2T10 Stirrups Cross-section (mm) Stirrups Reinforcement R6@100 R6@100 200 × 200 200 × 200 R6@100 R6@100 8T10 8T10 connected to the reaction wall using hinges to consider the horizontal restraints of the remaining frame on the extracted frame. Two steel beams were used to fix the frame to the testing floor with four anchor bolts. Besides, to increase the stiffness of the reaction frame, the steel beam was fastened to the ground using four vertical tension rods. Due to the different lengths of the hydraulic jacks, connecting rods were used to link the hydraulic jack to the top of the side columns. Before testing, a constant vertical axial compression force of 152.8 kN was applied to each side column to simulate the load transferred from the upper storey, corresponding to an axial compression ratio of 0.2. Thereafter, a displacement-control loading was applied to the middle column at a rate of 2 mm/min using a hydraulic jack until final failure occurred. Fig. 5 shows the arrangement of the linear variable displacement transducers (LVDTs) and strain gauges. The vertical load applied was recorded by the load cell within the hydraulic jack, and the horizontal reaction force was monitored by load cells placed in the horizontal hinges. The vertical displacement of the middle column was monitored using LVDT R-3. Additionally, the vertical deflection of the beams in F-1 and at the first storey of F-2 was recorded by four LVDTs installed beneath the beams. Horizontal deformations of the columns were measured with LVDTs arranged along the column height. Strain gauges were employed to measure the strains in the longitudinal reinforcement of beams and columns. Beam clear span (mm) Number of storeys Horizontal restraint 2000 2000 1 2 Right side Right side stage. F-1 and F-2 maintained load capacities of 30 kN and 57 kN, respectively. As the displacement increased further, the vertical load increased gradually due to the onset of catenary action. F-1 achieved its catenary action capacity of 31.7 kN at 358 mm displacement (point D), only 5 % higher than its CAA capacity. Then, a sudden drop in the load of F-1 occurred due to the fracture of the bottom reinforcement on the left side of the middle joint, indicating the failure of the frame. Frame F2 eventually reached a load capacity of 63.7 kN under catenary action, 11.6 % higher than its CAA capacity, at a vertical displacement of 331 mm. Two sudden drops in the curve of F-2 corresponded to the fracture of the bottom reinforcement on the right side of the secondstorey middle joint at a displacement of 340 mm and that of the firststorey middle joint at 362 mm. Fig. 7 presents the horizontal reaction force-middle point displacement curves for the frames, with positive values in tension and negative values in compression. Initially, the horizontal compression force in F-1 gradually increased to the first peak at 115 mm displacement. As the vertical displacement increased, the axial compression force gradually decreased and was transformed into tension between 200 mm and 320 mm of vertical displacement. The plateau stage might be caused by connection gaps in the lateral restraint. Under catenary action, the horizontal force increased sharply once the vertical displacement exceeded 320 mm. Finally, the horizontal force was reduced due to the failure of the frame. For frame F-2, the horizontal force-displacement curve of the first storey was similar to that of F-1, but the peak compression of the former was larger than that of the latter. However, the horizontal force in the second storey remained in compression throughout the loading process. It initially increased rapidly to 5.0 kN at a 29 mm displacement, and then gradually dropped to 2.9 kN when the displacement reached 323 mm. Thereafter, a sharp increase in the horizontal force occurred at 340 mm displacement when steel rebars in the beam on the right of the second-storey middle joint fractured. Notably, the axial force in the second storey continued to increase after the steel rebars fractured, due to Vierendeel action in the frame under large deformation conditions. Table 3 summarizes the load resistances and the associated 3. Test results and discussions 3.1. Load-displacement curves Fig. 6 shows the vertical load-middle joint displacement curve of frames F-1 and F-2. Initially, the curve increased linearly, and steel rebars and concrete were in the elastic stage. Once the vertical displacements reached 20 mm for F-1 and F-2, respectively, the load started increasing slowly, as the longitudinal reinforcement in the beams near the middle joints began to yield. Then, F-1 reached its CAA capacity of 30.1 kN at a displacement of 52 mm (point C), while F-2 reached 57.1 kN at 67 mm (point A). Thereafter, the frames entered a plateau 3 J. Yuan et al. Structures 74 (2025) 108489 Fig. 2. Dimensions and reinforcement details of specimens. displacements of F-1 and F-2 at different stages. The CAA capacity of F-2 was 57.1 kN, 0.90 times greater than that of F-1, and the displacement at this capacity of F-2 was also larger than that of F-1. The load capacity of F-2 was 1.0 times greater than that of F-1, whereas the associated displacement of F-1 was 27 mm larger than that of F-2. Therefore, the load capacity of frames increased significantly as the number of storeys increased from one to two. However, the deformation capacity of F-2 was less than that of F-1, which might be caused by the larger bending moment at the middle joint at the second storey of F-2. two bottom steel rebars fractured at the middle joint, and crushing and spalling of the concrete were also observed in the compression zone at the beam end. Fig. 9 illustrates the failure modes of the beams in F-2. Fig. 9(a) shows that the beam in the first storey exhibited failure modes similar to those of F-1. However, the cracks in the second-storey beam were primarily located at the beam ends, without apparent tension cracks along the beam length, as shown in Fig. 9(b). It indicated that catenary action was not mobilized at the second storey. The bottom reinforcement adjacent to the middle joints at the first and second storeys fractured at 340 mm and 390 mm displacements, respectively. Moreover, at the middle joints, obvious crushing of concrete occurred at the top of the beam, while crushing of concrete appeared at the bottom of the beam at the side joints. Notably, the crushing of concrete at the beam ends at the second storey was more severe than at the first storey due to the presence of compressive forces in the beam. Fig. 10 illustrates the failure modes of side columns in F-1 and F-2. As depicted in Fig. 10(a and b), the left and right columns of F-1 exhibited different failure modes due to differences in the boundary condition. On the outside face of the column sections beneath the side joint, flexural 3.2. Crack patterns and failure modes Fig. 8 presents the failure modes of beams in F-1. Bending cracks occurred in the tension zone at the beam ends when the vertical displacement reached 20 mm. The cracks then propagated towards the compression zone, reducing the neutral axis depth and activating CAA. As the displacement increased, diagonal cracks developed at the beam end due to the combined effect of bending moment and shear force. Thereafter, catenary action induced axial tension in the beam, resulting in tension cracks along its length. At a vertical displacement of 370 mm, 4 J. Yuan et al. Structures 74 (2025) 108489 Fig. 3. Uniaxial tension tests of steel rebars. Table 2 Mechanical characteristics of steel reinforcement. Material Stirrup Longitudinal reinforcement R6 T10 T12 T18 Diameter (mm) Yield strength (MPa) Ultimate strength (MPa) Elastic modulus (GPa) Yield strain (με) 6 10 12 18 367 461 434 415 518 600 608 593 166 206 203 190 2713 2360 2090 2290 Fig. 5. Arrangement of LVDTs and strain gauges in F-2. the side joints at the first and second storeys due to CAA. Besides, flexural cracks were also observed on the outer face of the first-storey column near the footing due to catenary action. However, due to the presence of the horizontal restraint at the right joint of the first storey, CAA did not induce flexural cracks at the right column at the first storey. Under catenary action, bending cracks developed at the right joint at the first storey. Finally, evident crushing of concrete appeared at the footing of the left column. Notably, the right column exhibited smaller lateral deformations and fewer cracks than the left column due to the horizontal support. Fig. 4. Experiments setup for frames. cracks first emerged in the CAA stage. Multiple flexural cracks appeared close to the footing during the catenary action stage as a result of inward bending of the side columns under axial tension in the beam. As the vertical displacement increased, diagonal cracks developed at the side joint. Notably, the right column showed fewer bending cracks and a shorter diagonal crack than the left column, due to the restraint provided by the horizontal support. Finally, flexural failure of the column occurred due to the crushing of concrete at the base of the left column. Fig. 10(c and d) show the failure modes of the side columns in F-2. For the left column, flexural cracks appeared on the outer surface below 3.3. Deformation capacity 3.3.1. Deformation capacity of beams Fig. 11 illustrates the vertical deformation profiles of the beam at various load levels. Initially, each beam segment remained nearly 5 J. Yuan et al. Structures 74 (2025) 108489 Vertical load (kN) 80 F-1 F-2 A (67 mm,57.1 kN) 60 observed to be smaller than that of F-1. This was mainly due to that the beam at the second storey of F-2 provided an additional force redistribution path. B (331 mm,63.7 kN) θc = 40 C (52 mm,30.1 kN) 3.3.2. Deformation capacity of columns The lateral deflection of columns in F-2 was measured and analysed, as shown in Fig. 12. Positive values signify deflections towards the middle joint, while negative values denote deflections away from the joint. As seen in Fig. 12(a), at the CAA stage, the axial compression force pushed the side columns away from the joint, and then the side columns were pulled towards the joint by the axial tension force under catenary action. Catenary action induced greater deformations in the side column compared to CAA. Finally, the inward displacement of the column increased rapidly due to cracking on the outer side of the side column. The displacement of the second-storey column exceeded 62 mm at failure and beyond the range of the LVDTs. From the results of 2-L6 and 2-L8, it was found that the lateral deflection of the right column was nearly zero under CAA, and it was also noticeably smaller than that of the left column when catenary action started. Fig. 12(b) illustrates the deflections of the left column. Under CAA, the outward deflection at the first-storey joint was almost equal to that at the second-storey joint, indicating that the relative deformation between them could be ignored. However, under catenary action, the lateral deflection at the secondstorey joint exceeded that at the first-storey joint. The maximum lateral deflection of the left column reached 62.5 mm. Fracture of bars 0 100 200 300 400 Middle joint displacement (mm) 500 Fig. 6. Vertical load-displacement curves of frames. Horizontal force (kN) 20 10 0 -10 -20 F-1 1st storey of F-2 2nd storey of F-2 -30 -40 0 100 200 300 400 Middle joint displacement (mm) 500 3.4. Strain development Fig. 7. Horizontal reaction force-displacement curves of frames. Fig. 13 presents the strain development of steel reinforcement at the beam mid-span of F-2. The analysis focused on the left beam segments, due to the consistent strain variations observed between the left and right beam segments. The strain at 1-BT3-L and 1-BB4-L were consistently tensile, while the strain at 1-BB3-L was kept compressive. Interestingly, the strain at 1-BT4-L changed from compressive to tensile at a displacement of 280 mm, signifying the change from CAA to catenary action in the first storey. However, as illustrated in Fig. 13(b), the axial force at 2-BT4-L at the equivalent position 1-BT4-L on the second storey remained compressive throughout testing, indicating that catenary action did not occur in the second storey. Fig. 14 presents the strain development of steel rebars in columns of F-2. Fig. 14(a) displays that the reinforcement strain in the left column of F-2 was similar to that of F-1. Notably, the strain at 2-CB3-L, located at the bottom of the second-storey column, did not change from tensile to compressive. This might be due to the inward movement of the firststorey column and the downward rotation of the first-storey beam. Moreover, at the CAA stage, the strain of the first-storey column was larger than that of the second-storey column, suggesting more deformations in the first-storey column under CAA. Fig. 14(b) displays the strain development of the steel rebars in the right column. At the CAA stage, the strains in the first-storey column were close to zero due to the presence of horizontal restraints connected to the column. After a displacement of 340 mm, the strains at 1-CT1-R, 1-CT3-R and 2-CB1-R increased significantly. It was due to that the steel rebar at the second-storey middle joint fractured, which increased the axial tension of the first-storey beam, thereby increasing the bending moment at the top of the first-storey column and the bottom of the second-storey column. Besides, the fracture of the reinforcement also caused a decrease in the reinforcement strain in the second-storey beam, significantly reducing the strains at 2-CT1-R and 2-CT3-R at the top of the second-storey column. Table 3 Load capacities and associated displacements of frames. Specimen F− 1 F− 2 Compressive arch action Catenary action/ the second peak capacity CAA capacity (kN) Displacement (mm) Load capacity (kN) Displacement (mm) 30.1 57.1 52 67 31.7 63.7 358 331 (1) where θc represents the chord rotation of beams, δm represents the ultimate displacement at the middle joint, and ln represents the net span of the beam. D (358 mm,31.7 kN) 20 0 δm ln straight, and the rotation primarily occurred near the joint. F-1 exhibited symmetrical deformation, as shown in the Fig. 11(a). The difference in final deformation was caused by the fracture of the bottom reinforcement at the beam end close to the middle joint. In F-2, the deformation of the first-storey beam remained symmetrical even after the bottom reinforcement fractured at the beam end at the second-storey middle joint, as shown in Fig. 11(b). However, the deformation of the firststorey beams in F-2 became different after the bottom steel reinforcement fractured at the first-storey joint. Table 4 includes the plastic hinges at the middle joint and the side column rotating. These rotations were determined by dividing the ultimate displacement at R3 by the net span of beams and by dividing the ultimate displacement at R1 by the distance from R1 to the left column. The chord rotation of the beams was determined by the ratio of the ultimate displacement at the middle joint to the net span of the beams, as expressed in Eq. (1) [32]. It was found that the chord rotation was more significant than the rotation of the plastic hinges at the middle joints. These rotations surpassed the rotation threshold of 0.20 rad prescribed in UFC 4–023–03, which is required for beams to develop alternate load paths. Notably, in the first storey of F-2, the plastic hinge rotation was 6 J. Yuan et al. Structures 74 (2025) 108489 Fig. 8. Failure modes of beams in F-1. Fig. 9. Failure modes of beams in F-2. Fig. 10. Failure modes of side columns in F-1 and F-2. 7 Vertical displacement (mm) Vertical displacement (mm) J. Yuan et al. 100 Structures 74 (2025) 108489 Left side column 0 R3 R2 catenary action. The relationship between the axial tension force (Tb1 ) in the beam, the bending moment (Mb1 ) at the end of the first-storey beam, and the bending moment (MA1 ) at the bottom of the left column can be obtained from Eq. (2). Moreover, the effect of shear (Vb1 ) is ignored as shear diminishes under catenary action. Right side column Penultimate column R1 R4 R5 -100 -200 -300 -400 Original position CAA CA Bar fracture Final The beam as a rigid segement MA1 + Vc (l1 + l2 ) = Mb1 + Tb1 ⋅l1 where MA1 is the bending moment at the bottom of the left column, Vc is the shear force at the inflection point, l1 and l2 are the distances measured from the centre of the first-storey beam to the bottom of the first-storey column and the inflection point of the second-storey column, Mb1 is the bending moment at the end of the first-storey beam, and Tb1 is the axial tension force in the first-storey beam. Fig. 16 displays the relationship between the axial force and the bending moment [24]. Between the point (M0 , 0) corresponding to the pure flexure of the beam section and the point (M1 , T1 ) corresponding to the tensile yielding of the top and bottom reinforcement, it is assumed that the axial force and bending moment followed a linear relationship. When all reinforcement yields, the negative moment was not zero as the cross-sectional area of the top reinforcement is larger than that of the bottom reinforcement. The correlation between the negative bending moment and the axial tension can be established as follows: -500 -2500 -2000 -1500 -1000 -500 0 500 1000 1500 2000 2500 Monitor point position (mm) 100 (a) F-1 Left side column 2-R1 0 Right side column Penultimate column 2-R3 2-R2 2-R4 2-R5 -100 -200 -300 -400 Original position CAA CA 2nd bar fracture 1st bar fracture Final The beam as a rigid segement -500 -2500 -2000 -1500 -1000 -500 0 500 1000 1500 2000 2500 Monitor point position (mm) (b) F-2 Tb1 = Fig. 11. Vertical deformation profiles of beams in frames. F− 1 The first storey of F− 2 Rotation of plastic hinges at middle joint (rad) Rotation of plastic hinges at side column (rad) Left Right Mean value Left Right Mean value 0.22 0.20 0.22 0.22 0.22 0.21 0.24 0.23 0.22 0.21 0.23 0.22 Chord Rotation θc (rad) 0.24 0.24 4. Simplified calculation method In the scenario of penultimate column removal at the first storey, as the first storey entered the catenary action stage, Vierendeel action commenced in the frame, with the second-storey beam in compression and the first-storey beam in tension. Assuming that the inflection point of the second-storey column was located at the mid-height of the column, simplified models of the first and second storeys were established to calculate the load capacity of the double-storey frame. Fig. 15 presents the force equilibrium of the left column under 2-L1 2-L2 2-L3 2-L4 50 40 Pca = 2-L6 2-L8 30 20 10 0 -10 0 100 200 300 400 Middle joint displacement (mm) (3) 2(Mb + Mm + βl Tb δ) (4) where βl is the net span length of the single-span beam, Mm is the bending moment of the beam at the middle joint, δ is the vertical displacement of the middle joint, taken as the vertical displacement when the chord rotation of the beam is 0.2 rad [22]. The sagging moment (Mm ) at the middle joint can be obtained from the interaction Distance to bottom support (mm) Side column deflection (mm) 70 60 M0 − Mb1 T1 M0 − M1 where M0 is the moment capacity of the beam in pure flexure, M1 and T1 are the bending moment and axial force when the top and bottom reinforcement yields simultaneously. The axial compression force (Nva ) in the second-storey beam is estimated to be 25.6 kN based on the model Wang [33], and it is also assumed that this force is equal to the peak axial compression force at the CAA stage when frame F-2 attains its load capacity. Therefore, the shear force at the inflection point (Vc ) is equal to 25.6 kN. Moreover, the reinforcement at the bottom of the left column yields. Using the cross-sectional area of the reinforcement and mechanical properties, the bending moment (MA1 ) is calculated to be 24.2 kN⋅m. Eqs. (2) and (3) can be used to calculate the bending moment (Mb ) and the associated axial tension force (Tb ). Fig. 17 shows the force equilibrium of the first-storey beam under catenary action. Eq. (4) expresses the catenary action capacity (Pca ). Table 4 Plastic hinge and chord rotations under catenary action. Storey (2) 500 (a) Side column deflection-middle joint displacement curve 3000 Original position 2500 2000 1500 1000 CAA-67 mm CA-331 mm 1st fracture-340mm 2nd fracture-390mm Final-480 mm 500 0 -20 0 20 40 60 Lateral deflection (mm) 80 (b) Lateral deflections of the left side column Fig. 12. Lateral deflections of column in F-2. 8 J. Yuan et al. Structures 74 (2025) 108489 3000 3000 Yield strain 1000 0 -1000 -2000 -3000 0 1-BT3-L 1-BT4-L Yield strain 2000 1000 Strain (µe) Strain (µe) 2000 -1000 1-BB3-L 1-BB4-L Yield strain 100 200 300 400 Middle joint displacement (mm) 0 2-BT3-L 2-BT4-L -2000 -3000 0 500 2-BB3-L 2-BB4-L Yield strain 100 200 300 400 Middle joint displacement (mm) 500 (b) Left beam segment in the second storey (a) Left beam segment in the first storey Fig. 13. Strain development of steel rebars at beam mid-span of F-2. 3000 Yield strain 2000 1000 Strain (µe) Strain (µe) 2000 3000 0 -1000 -2000 -3000 0 1-CT4-L 2-CT3-L 1-CT1-L 1-CB1-L 2-CB1-L 1000 0 -1000 2-CT1-L 1-CB4-L 2-CB3-L Yield strain 100 200 300 400 Middle joint displacement (mm) Yield strain 1-CT1-R 2-CT1-R 2-CB1-R -2000 -3000 0 500 (a) Left column 1-CT3-R 2-CT3-R 1-CB3-R 2-CB3-R Yield strain 100 200 300 400 Middle joint displacement (mm) 500 (b) Right column Fig. 14. Strain development of steel rebars at column sections of F-2. 400 200 Axial force (kN) Negative moment Assumed relationship Positive moment T1 0 M0 M1 -200 -400 -600 0 10 20 30 40 Moment (kN·m) 50 60 Fig. 16. Relationship between bending moment and axial force. Fig. 17. Force equilibrium of first-storey beam under catenary action. the sagging moment of the beam at the middle joint (Mva ) is 14.2 kN⋅m. The load capacity of the second-storey beam under Vierendeel action can be obtained from Eq. (5). Fig. 15. Force equilibrium of left side column under catenary action. diagram of the axial force and bending moment, as depicted in Fig. 16. Fig. 18 shows the force equilibrium of the second-storey beam under Vierendeel action. According to Fig. 16, with an axial force of 25.6 kN, 2 Pva = (Nva (l3 − δ) + Mva ) βl (5) where Pva is the second-storey beam load capacity under Vierendeel 9 Structures 74 (2025) 108489 J. Yuan et al. 5.3. Discussion of numerical results 5.3.1. Force in each storey Based on the numerical results, the vertical load sustained by each storey of the frame can be obtained from the force equilibrium of the middle joints at each storey. Fig. 22 shows the force equilibration of the middle joint in the first storey of F-2. The vertical load carried by the first-storey frame (P1 ) can be obtained from Eq. (6). Fig. 18. Force equilibrium of second-storey beam under Vierendeel action in F-2. P1 = V1L cosθ + N1L sinθ + V1R cosθ + N1R sinθ action, l3 is the distance from the centroid of the second-storey beam to the inflection point of the second-storey column. The total load capacity of frame F-2 is determined by superposing the catenary action capacity of the first-storey beam and the resistance of the second-storey beam under Vierendeel action. As shown in Table 5, the analytical and experimental load capacity of F-2 are determined to be 58.1 kN and 63.7 kN, respectively. The ratio of analytical to experimental results is 0.91, indicating good agreement between the analytical and test results. (6) where V1R and V1L are the shear forces in the right and left beams near the middle joint of the first storey, respectively, N1R and N1L are the axial forces in the right and left beams at the first storey, and θ is the relative rotation angle of the first-storey beam. Fig. 23(a) shows that the load sustained by the first and second storeys are almost the same during the flexural and CAA stages. Once the displacement reaches about 240 mm, the load on the first storey increases due to the commencement of catenary action, but the load on the second storey gradually decreases. The curves of the beam at the first and second storeys experience a sudden drop at 325 mm and 360 mm, respectively, corresponding to the fracture of the bottom reinforcement of the beam at the middle joint in each storey. Before a displacement of 240 mm is reached, the loads on the first and the second storeys account for about 50 % of the total load, respectively, as displayed in Fig. 23(b). However, once the frame reaches its load capacity, the proportion of the load sustained by the beam at the first storey increases to 61.6 %, but the portion carried by that at the second storey decreases to 38.4 %. 5. Numerical simulations of frames 5.1. Finite element model and material models Considering the negligible out-of-plane deformation of frames observed during testing, a two-dimensional plane model is established by DIANA for the frame with a removed first-storey middle column, as shown in Fig. 19. The plane-stress element CQ16M is utilized for concrete, and the embedded reinforcement rebar element is used for the reinforcement in DIANA software. The bond between concrete and reinforcement is ignored due to the use of embedded reinforcement elements [27]. The model mesh size is determined to be 30 mm. Notably, the horizontal stiffness of the frame is simulated by spring elements at the beam extension, with the axial stiffness for the first and second-storey beams set as 15 kN/mm and 20 kN/mm, respectively. Fig. 20(a) shows that the stress-strain curve of steel reinforcement is simplified as a piece-wise linear model, with the mechanical properties obtained from tension tests. The rotating crack model depend on total strain is used for the concrete. The concrete models in tension and compression are the nonlinear softening model developed by Hordijk and the model developed by Maekawa, respectively, as displayed in Fig. 20(b and c). 5.3.2. Internal force in beams Fig. 24 shows the variation of forces in beams of F-2, with the force acting at the beam mid-span. During the CAA stage, the axial force in the first-storey beam is in compression, and is shifted to tension at 240 mm due to the commencement of catenary action, as displayed in Fig. 24(a). However, the axial force in the second-storey beams remains in compression throughout the loading process. Fig. 24(b) presents the shear force-displacement curve in beams. The curves in the first-storey beam are consistent with those in the second-storey beam before a displacement of 240 mm is reached. Then, the shear force in the firststorey beam begins to increase due to the onset of catenary action, whereas the shear force in the second-storey beam decreases gradually. 5.3.3. Mechanism under Vierendeel action Vierendeel action in double-storey reinforced concrete frames is characterized by axial tension in the first-storey beam and axial compression in the second-storey beam. According to the abovementioned analysis, the second-storey resistance is mainly provided by the bending moment at the beam end and the axial force in the beam. Thus, a parameter α is defined to represent the contribution of Vierendeel action to the resistance of the second storey, β represents the contribution of the bending moment at the second-storey beam end to the resistance of the second storey, γ represents the contribution of Vierendeel action to the overall resistance of F-2, as expressed in Eqs. (7–9). 5.2. Model validation Fig. 21 presents a comparison between the test and numerical results of F-2. As illustrated in Fig. 21(a), the numerical vertical loaddisplacement curve shows good agreement with the test curve, and the numerical model accurately predicts the load capacity of F-2 at each stage. Moreover, the numerical horizontal displacement-displacement curve agrees well with the experimental results, and the numerical model effectively predicts the outward and inward deflections of the left column relative to the middle joint, as displayed in Fig. 21(b). Fig. 21(c) shows that the failure mode and crack distribution in the numerical results are consistent with those observed in the experimental results. Table 5 The resistance of F-2 under catenary action and Vierendeel action. Frame Simplify calculation model Resistance of single-storey under catenary action Pc (kN) F− 2 The first storey The second storey 38.8 Experimental result Resistance of single-storey under Vierendeel action Pva (kN) 19.32 10 Load capacity of frame Pca (kN) Load capacity of the frame Peca (kN) 58.1 63.7 Pca /Peca 0.91 J. Yuan et al. Structures 74 (2025) 108489 s ft fu fy 0 ?y ?s,h ?s,u Tensile strain (a) Piece-wise linear model for reinforcement s Tensile stress Tensile stress Fig. 19. Numerical modelling for F-2. ? GIf /h 0 ? Tensile strain (b) Hordijk model for concrete tension fc' (c) Maekawa model for concrete compression Fig. 20. Constitutive models for concrete and steel reinforcement. Horizontal displacement (mm) Vertical load (kN) 80 60 40 20 0 Test result FEA result 0 100 200 300 400 Displacement (mm) 500 (a) Vertical load-displacement curves 80 L-1/Test L-2/Test L-3/Test L-4/Test 60 40 L-1/FEM L-2/FEM L-3/FEM L-4/FEM 20 0 -20 0 100 200 300 400 500 Middle point displacement (mm) (b) Horizontal displacement- displacement curves (c) Failure modes Fig. 21. Comparisons of experimental and numerical results of F-2. 11 J. Yuan et al. Structures 74 (2025) 108489 of the second-storey beam increases from 51.1 % to 64.0 %. Besides, the contribution of Vierendeel action to the overall resistance of F-2 decreases from 23.0 % to 13.8 % with increasing vertical displacement due to the larger catenary action in the first-storey beam and the bending moment at the second-storey beam end. Fig. 22. Force equilibration of the middle joint at the first storey of F-2. Nva (l3 − δ) Pva βl/2 (7) β= Mva Pva βl/2 (8) γ= Nva (l3 − δ) Pβl/2 (9) To accurately simulate the boundary restraints of the frame, a numerical model of the double-storey, four-span frame (F2B4) is Contribution to resistance (%) α= 5.4. Influence of the number of storeys where P is the overall vertical load carried by frame F-2, Pva is the resistance obtained by the second-storey beam under Vierendeel action, Nva is the axial force in the second-storey beam under Vierendeel action, Mva is the bending moment at the beam end near the middle joint at the second storey, and l3 is the distance between the second-storey beam and the inflection point of the second-storey column. The contribution of Vierendeel action and the bending moment at the second-storey beam end to the resistance of the second storey is calculated based on numerical results, as shown in Fig. 25. With the vertical displacement increases, the contribution of Vierendeel action to the resistance of the second-storey beam decreases from 48.9 % to 36.0 %, while the contribution of the bending moment to the resistance Total load First storey (330 mm,55.3 kN) Second storey 60 35 mm,56.8 kN) (360 mm,41.9 kN) 40 (35 mm,28.9 kN) (35 mm,27.9 kN) 20 0 (325 mm,24.8 kN) 0 80 60 64.0 51.1 40 48.9 20 0 36.0 23.0 13.8 240 260 280 300 320 Middle joint displacement (mm) 100 80 60 40 20 0 100 200 300 400 Middle joint displacement (mm) (a) Vertical load carried by single-storey frame a ß ? Fig. 25. Contribution of Vierendeel action and bending moment to the resistance. Percent of total load (%) Vertical load (kN) 80 100 Second storey First storey 0 100 200 300 400 Middle joint displacement (mm) (b) Contribution of the load carried by each layer of the frame to the total load Fig. 23. Load resistance of beams at each storey in frame F-2. 40 1st-AB beam 2nd-AB beam 1st-BC beam 2nd-BC beam 40 20 Shear force in beam (kN) Axial force in beam (kN) 60 0 -20 -40 0 20 0 -20 -40 100 200 300 400 Middle joint displacement (mm) (a) Axial force 1st-AB beam 1st-BC beam 0 100 200 300 400 Middle joint displacement (mm) (b) Shear force Fig. 24. Variation of forces in beams of F-2. 12 2nd-AB beam 2nd-BC beam J. Yuan et al. Structures 74 (2025) 108489 established, and its modelling method, material parameters and loading method are consistent with those of F-2, as shown in Fig. 26(a). Besides, to study the effect of the storey number on the resistance of multi-storey planar frames, models F3B4, F4B4 and F5B4 are developed based on the F2B4 model, as shown in Fig. 26(b-d). Fig. 27 shows the vertical load-displacement curve of multi-storey planar frames. The CAA capacities of F3B4, F4B4 and F5B4 are 1.48 times, 1.96 times and 2.45 times as much as that of F2B4, respectively. Moreover, the load capacities of F3B4, F4B4 and F5B4 are 1.55 times, 2.00 times and 2.54 times as much as that of F2B4. Therefore, in scenarios with the penultimate column on the first storey being removed, the CAA and load capacities of the multi-storey planar frame show a roughly linear increase with the storey number. However, the effect of the number of storeys on the deformation capacity of multi-storey frames can be neglected. Fig. 28 illustrates the vertical load-displacement curve of each beam in multi-storey frames. It is evident that the curves of the middle storeys are almost the same. At the CAA capacity, the first storey contributes the most to the total load, the middle storey contributes the least to the total load, and the difference in the load sustained by each storey is insignificant. With the displacement increases, the load sustained by the firststorey beam increases significantly due to the mobilisation of catenary action in the first storey. Meanwhile, the load sustained by the beam in the middle storey gradually increases, whereas the vertical load on the top storey remains relatively constant. Upon the load capacity is reached, the first-storey beam still contributes the most to the total load, but the smallest contribution to the total load comes from the top storey. This indicates different vertical load transfer mechanisms are mobilised at the first, middle and top storeys. Vertical load (kN) 200 163.2 135.4 100 129.2 108.6 99.9 81.9 50 0 55.3 0 64.3 F2B4 F4B4 F3B4 F5B4 100 200 300 400 Middle joint displacement (mm) Fig. 27. Vertical load-displacement curve of multi-storey planar frames. storey joint of F-2, while no tensile cracks were found along the beam span at the second storey. (3) In F-2, the reinforcement at 1-BT-L was shifted from compression to tension due to the development of catenary action, whereas the steel rebars at the corresponding position in the second-storey beam remained under compression. This highlighted the difference in the force transfer mechanisms between the first and second storeys of F-2. (4) Assuming that the inflection point of the column is at the midpoint of the second-storey column, a method was developed to obtain the load capacity of the double-storey frame. This method assumes that the negative bending moment varies linearly with the axial force in the beam. It can accurately predict the load capacity of the frame, with the ratio of the calculated to experimental load capacity of 0.91. (5) According to the verified finite element model, the contribution of Vierendeel action to the load capacity decreases with increasing displacement. Moreover, frames with varying numbers of storeys exhibit different force transfer mechanisms, and the load capacities of the frames increase nearly linearly with the number of storeys. At the CAA capacity, the first-storey beam contributes the most to the total load, while the middle-storey beam contributes the least. However, at the ultimate load capacity, the contribution of the middle-storey beam to the overall load exceeds that of the top-storey beam. 6. Conclusions This paper explores the resistance, failure modes, and reinforcement strain development of two reinforced concrete planar frames under a scenario of removing the penultimate column. The frames were tested under a quasi-static pushdown loading regime to analyse the influence of the number of storeys on the resistance of frames. Subsequently, a simplified model was proposed to quantify the collapse resistance of double-storey frames. Besides, a numerical model of multi-storey frames was developed by using Diana finite element software to study the mechanism of Vierendeel action. The following conclusions can be drawn: CRediT authorship contribution statement (1) The vertical load-middle joint displacement curves of frames F-1 and F-2 were similar in shape, consisting of an elastic stage and a CAA stage. However, unlike F-1, the first storey of F-2 exhibited catenary action after CAA, while the second-storey beam was always under axial compression. The CAA and load capacities of F-2 were 0.9 and 1.0 times greater than those of F-1, respectively. (2) Damage in frame F-1 and the first storey of F-2 included crushing of concrete and tensile cracking at the joints, fracture of beam rebars at the middle joint, tensile cracks along the beam span, and crushing of concrete at the bottom of the first-storey column. Besides, more severe crushing of concrete appeared at the second- (a) F2B4 150 Load capacity CAA capacity Liu Kun: Writing – original draft, Investigation, Formal analysis, Data curation, Conceptualization. Wang Shan: Methodology, Investigation, Formal analysis, Data curation, Conceptualization. Tan Liang: Investigation, Formal analysis, Data curation. Kang Shao-Bo: Writing – original draft, Visualization, Project administration, Funding acquisition, Formal analysis. Yuan Jian: Writing – original draft, Investigation, Funding acquisition, Formal analysis. (b) F3B4 (c) F4B4 Fig. 26. Geometric model of multi-storey planar frames. 13 (d) F5B4 J. Yuan et al. Structures 74 (2025) 108489 50 40 30 20 10 0 0 100 200 300 400 Middle joint displacement (mm) (a) F3B4 60 First storey Second storey Third storey Fourth storey 50 40 30 20 10 0 0 100 200 300 400 Middle joint displacement (mm) (b) F4B4 60 Vertical load (kN) First storey Second storey Third storey Vertical load (kN) Vertical load (kN) 60 First storey Second storey Third storey Fourth storey Fifth storey 50 40 30 20 10 0 0 100 200 300 400 Middle joint displacement (mm) (c) F5B4 Fig. 28. Vertical load-displacement curve of a single-storey beam in multi-storey frames. Declaration of Competing Interest [13] Xiao Y, Kunnath S. Collapse test of three-story half-scale reinforced concrete frame building. Acids Struct J 2015;112(4):429–38. [14] Ren L-M, Liew JYR, Chen K, Yang B. Component tests and numerical simulations of 3D steel frame structures for progressive collapse. Eng Struct 2024;317:118691. [15] Vinay M, Kodanda Rama Rao P, Dey S, Swaroop AHL, Sreenivasulu A, Venkateswara Rao K. Evaluation of progressive collapse behavior in reinforced concrete buildings. Structures 2022;45:1902–19. [16] Qian K, Li B. Dynamic performance of RC beam-column substructures under the scenario of the loss of a corner column—Experimental results. Eng Struct 2012;42: 154–67. [17] Lu X, Lin K, Li C, Li Y. New analytical calculation models for compressive arch action in reinforced concrete structures. Eng Struct 2018;168:721–35. [18] Di Trapani F, Sberna AP, Di Benedetto M, Villar S, Demartino C, Marano GC. Dynamic progressive collapse response of multi-storey frame structures with masonry infills. Structures 2023;54:1336–49. [19] ACI 318-14. Building code requirements for structural concrete. Farmington Hills, MI: American Concrete Institute (ACI); 2014. [20] European Standard EN 1991-1-7. Eurocode 1-actions on structures-part 1-7: general actions-accidental actions. Brussels, Belgium: European Committee for Standardizatio; 2006. [21] Progressive collapse analysis and design guidelines for new federal office buildings and major modernization projects. Washington, DC, USA: General Services Administration; 2003 [22] UFC 4–023-03 Design of buildings to resist progressive collapse, DoD (Department of Defense), Washington, DC: Unified Facilities Criteria; 2009 [23] Kang S-B, Tan KH. Analytical model for compressive arch action in horizontally restrained beam-column subassemblages. Acids Struct J 2016;113(4):813–26. [24] Long X, Wang S, Huang X-J, Li C, Kang S-B. Progressive collapse resistance of exterior reinforced concrete frames and simplified method for catenary action. Eng Struct 2021;249:113316. [25] Izzuddin BA, Vlassis AG, Elghazouli AY, Nethercot DA. Progressive collapse of multi-storey buildings due to sudden column loss - part I: simplified assessment framework. Eng Struct 2008;30(5):1308–18. [26] Feng F-F, Hwang H-J, Zhou Y, Sun J-M, Zhang H-Z, Roh J-H, et al. Effect of threedimensional space on progressive collapse resistance of reinforced concrete frames under various column removal scenarios. J Build Eng 2024;90:109405. [27] Fu Q-L, Tan L, Long B, Kang S-B. Numerical investigations of progressive collapse behaviour of multi-storey reinforced concrete frames. Buildings 2023;13(2):533. [28] Code for design of concrete structures (GB50010–2010). Beijing, China: China Architecture and Building Press; 2010 [29] N.S.o.t.P.s.R.o. China. Code for seismic design of buildings (GB50011-2010). Beijing, China: China Architecture and Building Press; 2010. [30] Yu J, Tan KH. Experimental and numerical investigation on progressive collapse resistance of reinforced concrete beam column sub-assemblages. Eng Struct 2013; 55:90–106. [31] CISA. Metallic materials-tensile testing-part 1: method of test at room temperature, GB/T 228 1-2010, 2010. Beijing: Chinese Standard Press; 2010. [32] D.o.D. (DoD), Design of buildings to resist progressive collapse (UFC 4-023-03), in: U.F. Criteria (Ed.) Washington, DC, 2013. [33] Wang S, Peng J, Kang S-B. Evaluation of compressive arch action of reinforced concrete beams and development of design method. Eng Struct 2019;191:479–92. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Acknowledgements The authors gratefully acknowledge the financial support provided by the National Natural Science Foundation of China (No. 52278145), by the Luzhou Science and Technology Program, China (no. 2022-GYF2), and by Scientific and Technological Research Program of Chongqing Education Commission (grant no. KJQN202004010 and KJZDK202204001). References [1] Gao S. Life cycle sustainability assessment of concrete-filled steel tubular frames in earthquake regions. Eng Struct 2025;328:119761. [2] Su Y, Tian Y, Song X. Progressive collapse resistance of axially-restrained frame beams. Acids Struct J 2009;106(5):600–7. [3] Kang S-B, Tan KH. Robustness assessment of exterior precast concrete frames under column removal scenarios. J Struct Eng 2016;142(12):04016131. [4] Kang S-B, Tan KH. Behaviour of precast concrete beam–column sub-assemblages subject to column removal. Eng Struct 2015;93:85–96. [5] Qian K, Liang S-L, Xiong X-Y, Fu F, Fang Q. Quasi-static and dynamic behavior of precast concrete frames with high performance dry connections subjected to loss of a penultimate column scenario. Eng Struct 2020;205:110115. [6] Yu J, Tan KH. Structural behavior of RC beam-column subassemblages under a middle column removal scenario. J Struct Eng 2013;139(2):233–50. [7] Foster SJ, Bailey CG, Burgess IW, Plank RJ. Experimental behaviour of concrete floor slabs at large displacements. Eng Struct 2004;26(9):1231–47. [8] Lu X, Lin K, Li Y, Guan H, Ren P, Zhou Y. Experimental investigation of RC beamslab substructures against progressive collapse subject to an edge-column-removal scenario. Eng Struct 2017;149:91–103. [9] Gu X-L, Zhang B, Wang Y, Wang X-L. Experimental investigation and numerical simulation on progressive collapse resistance of RC frame structures considering beam flange effects. J Build Eng 2021;42:102797. [10] Stinger SM, Orton SL. Experimental evaluation of disproportionate collapse resistance in reinforced concrete frames. Acids Struct J 2013;110(3):521–9. [11] Sagiroglu S. Analytical and experimental evaluation of progressive collapse resistance of reinforced concrete structures. Boston: Northeastern University; 2012. [12] Yi W-J, He Q-F, Xiao Y, Kunnath SK. Experimental study on progressive collapseresistant behavior of reinforced concrete frame structures. Acids Struct J 2008;105 (4):433–9. 14
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )