Laboratory Report 10 Major and Minor losses By Kolby Goines Course: ENME 3070L CRN: 40529 Date: November 12, 2025 Instructor: Kidambi Sreenivas, PhD 1 Objectives The objective of this lab is to observe the major and minor losses in pipe flow. This will be followed through a stainless-steel pipe, along with various pipe components. 2 Theory The conservation of energy states that energy can neither be created nor destroyed, but transformed from one form to another. This principle, applied to a control volume, is that the rate of change of energy is caused by energy flowing in or out of the volume (Spakovszky). Bernoulli’s equation is a physical expression of the conservation of energy applied to fluid flow. It states that the total mechanical energy of a particle remains constant along a streamline for an ideal, incompressible, and frictionless fluid. However, in real-world applications, fluids experience energy losses due to friction and turbulence, converting this mechanical energy into heat. To account for this energy loss, Bernoulli’s equation is modified to include a term defined as head loss, Equation 1. π1 πΎ π£2 π2 2π πΎ + 1 + π§1 = π£2 + 2 + π§2 + βπΏ 2π (1) Where ‘βπΏ ’ is the head loss of the fluid as it flows through the system. However, for flow through a pipe, the dynamic energy terms and potential energy terms are constant for the flow, leaving those terms to cancel, Equation 2. βπΏ = π1 −π2 πΎ If there are elevation changes in the system, of course, they do need to be accounted for. However, the only time that an elevation change is significant for fluid flow is for those with (2) denser properties (i.e., water, mercury). In a fluid such as air, its density is much smaller than that of water, so a small change in height does not really affect the overall value. Therefore, proving the elevation changes to be insignificant without a major shift in height. Although for the scope of this experiment, the elevation changes will be accounted for due to the fluid of interest being water, Equation 3. βπΏ = π1 −π2 πΎ + (π§1 − π§2 ) (3) Head loss takes on the form of two subtypes of losses: Major losses and minor losses. Major losses are caused by the viscous forces (internal friction) that a fluid experiences as it flows through a pipe. This dispels mechanical energy to heat, which results in a loss of head along the pipe length. The head loss for these major losses can be found to be directly related to the velocity head along with a ratio of length to diameter, Equation 4. πΏ π2 βπΏ = π π· 2π (4) Where ‘f’ is the friction factor, which is a dimensionless value that quantifies the resistance to flow in a pipe. Determining the friction factor relies heavily on the equivalent roughness, which is the representative value for the pipe roughness to model the same frictional behavior as the real surface. The friction factor is a value that represents how much resistance (energy loss) the fluid experiences as it flows through the pipe. One relationship that can be found between these two values is through the Moody chart, which shows the friction factor as a function of Reynolds number and equivalent roughness. Another relation between the two values is Haaland’s equation (5). 1 √π 6.9 π π· 1.11 ≈ −1.8 log [π π + ( 3.7 ) π· ] (5) Where ‘π’ is the equivalent roughness, ‘π ππ· ’ is the Reynolds number, ‘f’ is the friction factor, and ‘D’ is the diameter of the pipe. However, this relation is for a flow of turbulent nature (2100<Re<4000). If the flow is considered laminar (Re>2100), the equation simplifies to Equation 6. 64 π = π π π· (6) A minor loss is due to a fluid's flow being disrupted by a certain component of a pipe system. The disruption causes turbulent flow to form in the pipe, again, causing mechanical energy to be dissipated into heat, resulting in head loss. The components of interest for this experiment will be a long and short radius elbow, a strainer, expansion, and contraction. For the elbows, the head loss is found to be a product of the fluid changing direction, creating secondary flow in the bend, which causes turbulence. In the strainer, however, as the fluid flows through the mesh, it reduces the flow area for the fluid, forcing local acceleration. After the fluid exits the mesh, it begins to form turbulent tendencies in an attempt to re-expand, creating head loss. In expansions, the fluid attempts to expand to the pipe size increase, separating the liquid from the walls, causing turbulence. The fluid in a contraction, on the other hand, cannot follow the sharp inward corner due to the pipe size. This forces the flow to contract more than the size pipe and creates a vena contracta, which is a point where the area of flow is smallest and velocity is highest (Rice). The formation of a vena contracta creates turbulence in the system, which causes head loss. For each one of these fitting the head loss can be found directly proportional to the velocity head and loss coefficient (πΎπΏ ), Equation 7. π2 βπΏ = πΎπΏ 2π (7) The loss coefficient is a dimensionless value that quantifies the energy lost in a fluid due to friction or sudden changes in geometry. Also, it should be noted that the head loss for the elbow is a product of the change in elevation and the observed head loss, as described in Equation 3. 3 Observed Data The experiment for the major losses found in the stainless-steel pipe is found below, Table 1. The section of interest is 1m with a diameter of 0.0095m; the density and viscosity are that of water (1000kg/m^3 and 0.001 (kg/m-s). Table 1 – Observed major losses in stainless steel pipe Data Point 1 2 3 4 5 6 7 8 9 10 11 12 Target RPM 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Max Flow rate (lpm) 7.8 9.8 12.1 14.2 16.4 18.6 20.9 23.1 25.4 27.7 30 31.9 Head loss (mmH2O) 526 856 1263 1734 2268 2860 3536 4264 5068 5913 6880 7671 As well, the observed head loss for the long and short radius elbows, the strainer, the expansion, and the contraction are found below, Table 2. The elevation change for the short radius elbow was 0.124 m, and for the long radius elbow, 0.174 m. Table 2 – Observed head loss for pipe component Data Point Target RPM Flow (lpm) 1 2 3 4 5 6 7 8 9 1400 1600 1800 2000 2200 2400 2600 2800 Max 26 30.1 33.8 37.8 41.9 45.9 49.7 53.8 65.5 Head Loss ΔH, mm of water Short Radius Sudden Strainer Elbow Expansion 31 1160 15 51 1556 55 80 1984 93 104 2478 134 135 3005 176 160 3588 218 195 4200 270 230 4875 325 250 5300 360 Long Radius Elbow 29 46 70 92 112 148 168 200 210 Sudden Contraction 108 176 248 336 415 520 615 740 805 4 Analysis and Discussion of results In analysis of the major losses found in the stainless-steel pipe, Equation 4 will be used to determine the friction factor for the pipe (See Appendix). The head loss and basic dimensions are already known (or observed), but the Velocity needs to be calculated first (see appendix). Algebraically solving for the friction factor in Equation 4, we find the following values, Table 3. Table 3 – friction factor values for stainless-steel pipe Velocities (V) 1.834029261 2.304293174 2.845096674 3.338873783 3.856164087 4.373454392 4.914257892 5.431548196 5.972351696 6.513155197 7.053958697 7.500709414 Friction factor (f) 0.029147132 0.030048369 0.029082511 0.028991568 0.028428546 0.027870158 0.02729097 0.026939686 0.026483078 0.025980508 0.025771828 0.025413818 To further analyze these experimental values, an aspect of comparison is needed. The comparison here will be by the equivalent roughness value found from these friction factors through the use of Equation 5, to a standard value for the stainless-steel pipe. However, before this can be done, the Reynolds number (π π = πππ· π ) needs to be found for each of the velocities above. As well, Equation 5 is algebraically solved for the equivalent roughness value (see the appendix for both the Reynolds and roughness). The resulting values can be found in Table 4 below. Table 4 – Equivalent roughness values ε(mm) 1.3392E-02 2.4126E-02 2.3323E-02 2.5533E-02 2.4851E-02 2.3821E-02 2.2530E-02 2.2019E-02 2.0979E-02 1.9686E-02 1.9490E-02 1.8571E-02 The average of the equivalent roughness values resulted to be 0.0215 mm. A standard value for a commercial-grade stainless-steel pipe is about 0.015 mm or more. Thus, our averaged value falls relatively close to the standard value for stainless-steel pipes. Further, with respect to the Moody chart, another form of comparison is plotting the friction factors against the respective Reynolds numbers, Figure 1. 0.031 Friction facotr (f) 0.03 0.029 0.028 0.027 0.026 0.025 0 10000 20000 30000 40000 50000 60000 70000 80000 Reynolds number (Re) Figure 1 – Friction factor vs. Moody chart The comparison results in something that greatly resembles the trend of a Moody chart, without the equivalent roughness on the right side. In direct comparison with a Moody chart, this graph would fall in the early portion of the turbulent region on the Moody graph. A Moody chart is characterized into three regions. The first region is considered to be the laminar flow region, where the flow is smooth and the pipe roughness doesn’t affect the flow (Re < 2000). The second region is the Transitional Flow Region, where the flow alternates between turbulent and laminar flow (2000 ≤ Re ≤ 4000). Finally, the last section is the turbulent region (Re > 4000), which has three sub-regions. The smooth turbulent region, where the friction factor decreases as Reynolds increases, the transitionally rough region, where the friction factor depends on the surface roughness and Reynolds number, and the fully rough region, where the friction factor is almost completely constant (“Moody Chart (Diagram)”). Therefore, looking back at the plot, our graph clearly falls in the smooth turbulent region due to ‘f’ decreasing as ‘Re’ increases. Before the loss coefficient can be calculated for all the components, the velocity needs to be calculated again. Also, for the short and long radius elbows, the elevation change needs to be factored into the total head loss, as described in the theory section of this lab. The loss coefficient itself for each of the pipe components will be found by algebraically solving for ‘πΎπΏ ′ in Equation 7 (See appendix). The total head loss values along with their respective loss coefficients for the elbows can be found in Table 5 below. Table 5 – loss coefficient for elbows Long Radius Elbow (ππ³) 29 0.145 Loss coefficient (π²π³ ) 1.682950934 Short Radius Elbow (ππ³) 31 0.093 Loss coefficient (π²π³ ) 1.079409909 46 0.128 1.108478124 51 0.073 0.63217893 70 0.104 0.714249733 80 0.044 0.302182579 92 0.082 0.45027766 104 0.02 0.10982382 112 0.062 0.277085495 135 0.011 0.04916033 148 0.026 0.096827368 160 0.036 0.134068663 168 0.006 0.019058496 195 0.071 0.225525534 200 0.026 0.070478872 230 0.106 0.28733694 210 0.036 0.065837002 250 0.126 0.230429508 Total ππ³ Total ππ³ Before an average value can be found for each of the loss coefficients, Chauvenet’s criterion needs to be applied to each data set (See Appendix). The criterion found the loss coefficient values of 1.68 for the long radius elbow and 1.079 for the short radius to be outliers. Thus, averaging both the data sets results in a value of 0.35 for the long radius elbow and 0.25 for the short radius elbow. The standard value for a short radius flanged elbow is 0.3, for which our calculated value lies very close to (The Engineering toolbox). As well, the standard value for the long radius flanged elbow is 0.2 (assuming that both elbows were not threaded). Thus, both of our components produced solid results of loss coefficients. The same process was then applied to the strainer, expansion, and contraction. The resulting loss coefficient values can be seen below, Table 6. Table 6 – loss coefficients for strainer, expansion, and contraction Strainer (ππ³) Loss coefficient (K) 1160 13.46360747 Sudden Expansion (ππ³) 15 0.174098372 Sudden Contraction (ππ³) 108 1556 13.47493719 55 0.476299194 176 1.52415742 1984 13.62568722 93 0.638704088 248 1.703210902 2478 13.60717125 134 0.735819591 336 1.845040169 3005 13.42970826 176 0.786565276 415 1.854685168 3588 13.36217672 218 0.811860236 520 1.936547351 4200 13.34094706 270 0.857632311 615 1.95349582 4875 13.2147885 325 0.8809859 740 2.005937126 5300 9.692669794 360 0.658370024 805 1.472188525 Loss coefficient (K) Loss coefficient (K) 1.253508282 Again, the criterion is applied to give an accurate representation of our average loss coefficient value. The criterion determined that the K values of 9.69 for the strainer and 0.174 for the expansion were outliers. The average loss coefficient found for the strainer came out to be 13.44, for the expansion 0.73, and for the contraction 1.73. In comparison with standard values, the strainer resembled a dirty Y-strainer with a value greater than ten (Assuming that the strainer is not completely clean). The standard value for a sudden expansion ranges from 0.1 to 0.5; however, while our value may not lie in that range, it does not mean it is wrong. The expansion is dependent on the ratio of the area change; therefore, the more drastic the change, the higher the loss coefficient. For the contraction, a standard range is from 0.5-1.5, for which again our value does not lie in. The same principle again applies here as in the expansion: the harsher the change, the higher the loss. 5 Conclusion Understanding and accounting for head loss is an important aspect for a piping system, especially in regards to the efficiency, design, and safety of the system. Engineers must know the head loss of a system to be able to determine how much more energy needs to be provided to overcome those losses. If one can minimize the amount of loss throughout a system, it can improve the efficiency while reducing the energy costs. Further, the ability to identify the type of loss in a system tells where the energy is being lost, allowing for targeted treatment of the loss. The major losses found from the stainless-steel pipe (0.021 mm) proved strong results when compared to the standard value for a commercial-grade pipe (0.015 mm), with only a small error. As well, it was strongly supported through the plotted resemblance to the Moody Chart, which was also a great representation of the real-world application of the chart. The minor losses as held to be relatively consistent with the standard values. The short and long radius elbows came within a good range, with 0.35 against 0.3 for a flanged long radius elbow, and 0.25 against 0.2 for the flanged short radius elbow. The strainer produced a value (13.44) close to that of a dirty Y-strainer (>10). Finally, the expansion and contraction values both came out to be a little above the standard ranges – 0.73 for the expansion with a range of 0-0.5 and 1.73 for the contraction with a range of 0.5-1.5. However, this was theorized to be due to a drastic change in Area due to the dependence of expansion and contraction on area ratios. Overall, strong results came from this experiment while also providing extensive knowledge on head loss in a system. References “Chauvenet’s Criterion.” Statistics How To, 2025, www.statisticshowto.com/chauvenetscriterion/. Accessed 11 Nov. 2025. “Minor or Dynamic Loss Coefficients for Pipe and Tube System Components.” The Engineering ToolBox, www.engineeringtoolbox.com/minor-loss-coefficients-pipes-d_626.html. Accessed 12 Nov. 2025. “Moody Chart (Diagram).” tec-science, 4 July 2020, www.tec-science.com/mechanics/gasesand-liquids/moody-chart-diagram/. Accessed 11 Nov. 2025. Tec Science Rice, C. C. Effect of Sudden Expansion or Contraction in a Pipe upon the Flow of Water. University of Illinois, 1911. University of Illinois at Urbana-Champaign, https://archive.org/details/effectofsuddenex00rice. Spakovszky, Z. S. “2.5 Control Volume Form of the Conservation Laws.” Thermodynamics and Propulsion Lecture Notes, Massachusetts Institute of Technology, Fall 2008, web.mit.edu/16.unified/www/FALL/thermodynamics/notes/node19.html. Accessed 11 Nov. 2025. Massachusetts Institute of Technology+1 Appendix Generic velocity: This will be the calculation for every velocity term found in the lab. Since we know the flow rate of each data point, all we need to do is divide it by the crosssectional area of the pipe, since Q=VA. Also, our units must all be consistent. π= π = π΄ 1π3 1 πππ 7.8 πππ (1000πΏ ) ( 60 π ) π (4 (0.0095π)2 ) = 1.834 π π Friction factor: As described in the report, the friction factor will be found from algebraically solving Equation 4. The length (L) is 1 m diameter (D) is 0.0095m 1π π (526 ππ (1000 ππ)) (0.0095 π) (2 (9.81 2 )) π πΏπ βπΏ π·2π βπΏ = π π= = = 0.0291 π π· 2π πΏπ 2 (1 π) (1.834 ) π 2 Reynolds: The Reynolds number is found through the equation (π π = πππ· ) where density π and viscosity values are for water (1000 kg/m^3 and 0.001 kg/(m-s)). (1000 π π = ππ π ) (1.834 ) (0.0095 π) 3 π π = 17388.5 ππ (0.001 ) πβπ Equivalent Roughness: The equivalent roughness can be found through algebraically solving equation 5 for the equivalent roughness (π) 1 1 1.11 1 − 6.9 − 1.8√π 1.8 0.0291 √ ( ) ) π = 3.7π· (10 − = 3.7 9.5ππ (10 − π ππ· 1 1.11 6.9 ) = 0.0134ππ 17388.5 It should be noted that this equation is only valid for turbulent flow. Loss coefficient: The loss coefficient for every pipe component is found from equation 7 along with the values from Table 5, making sure all units are consistent π βπΏ 2π (0.145 π) (2 ∗ 9.81 π 2 ) πΎπΏ = 2 = = 1.683 π 2 π (1.3 π ) However, the head loss (βπΏ ) for the elbows must account for the elevation change, while the head loss in the other components does not. Chauvenet criterion: We will use the data from the long radius elbow experiment for a criterion example. Chauvenet’s criterion works by creating an acceptable range around the mean of the data and anything that falls outside that range will be considered an outlier. It does this by taking the ‘Z’ value that correlates to the value of ‘n’ for a data set, which is the number of data points (For our data set it is 1.915). That Z value is the maximum deviation a data point can have away from the mean. The calculated deviation of a data point is then put up against the Z value through an inequality. π> |ππ − ππ | π Which means that any number greater than the ‘Z’ factor will be removed from the data set. Where ‘ππ ’ is the data point of interest, ‘ππ ’ is the mean value of that data set, and ‘π’ is the standard deviation from the mean. So, taking the long radius elbow loss coefficient data Table 7 – criterion example K 1.682950934 1.108478124 0.714249733 0.45027766 0.277085495 0.096827368 0.019058496 0.070478872 0.065837002 The mean value for this data set is 0.49836 with a standard deviation of 0.5738. Using the relationship described above on the data set. Table 8 – deviation of criterion example deviation from mean 2.064259087 1.063186823 0.376207212 0.083788659 0.385592104 0.699708644 0.835228131 0.745623347 0.753712236 As can be seen the only data point that is an outlier is the highlighted one because 2.06>1.91. Thus, the data point is removed and the resulting data set is reaveraged to find a result of 0.35.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )